S UPERIOR P ERFORMANCE H O R I Z O N TA L P U L S E S TA R T M E TA L H A L I D E L I G H T I N G S Y S T E M • Longer life and higher lumen output compared to both HOR and universal lamps in horizontal operation • No POM base and socket required • Variety of tubular and elliptical outer jacket shapes and sizes for full cut-off fixtures PERFORMANCE IS EVERYTHING LIGHT OUTPUT POSITIONS 15° 15° AND OPERATING For lighting applications, performance is everything. The lamp and ballast are expected to provide uniform, bright light, as well as great lumen maintenance and long life. In most horizontal lighting applications, lamp light output and life are drastically effected. Published catalog lumens of Universal lamps are based on operation in the Vertical burning position. When these lamps are burned horizontally, they will lose as much as 25% of lamp life and 10% of its initial and mean lumens. Universal Any Position Thanks to Venture’s Horizontal Pulse Start lamp series, lamp performance in a horizontal burning position is Vertical ±15° vastly improved. 75° 75° Horizontal ±75° H75 Venture has created a horizontal pulse start lamp line that now offers long life and high lumens based on a better arc tube. This line of lamps is free of the problems associated with the POM base lamps and is offered in a variety of jacket sizes and wattages. There are several types of burn positions posted by all manufacturers. These different positions are: Universal (“U”), Vertical (“V”), Base Up (“BU”), and Horizontal (“HOR”). Pulse start arc tube in Base-up, Vertical or Universal operation Arc Stream Metal Halide Salts Universal Probe start arc tube in Horizontal operation Probe start HOR arc tube Venture’s H75 pulse start arc tube U NIVERSAL (U) When a metal halide lamp is turned sideways, two things occur: loss of lamp life as well and loss of lamp lumens. All lamp manufacturers publish these ratings. When the lamp burns on its side, gravity intervenes, and the arc between the electrodes begins to bow upwards. As this happens, the bow of the arc overheats on the upper quartz wall of the arc tube. This shortens the life of the lamp and often cause non-passive failures. The bow in the arc also reduces lumen output. The metal halide salts used in the chemistry of the arc tube lay at the bottom of the arc tube in the horizontal burning position; this creates a cool pool of halides. This pool affects the performance of the lamp, resulting in lower lumen output. H ORIZONTAL (HOR) A design technique with probe start HOR lamps used by Venture to help correct lumen output and lamp life loss is the usage of POM bases and sockets. The electrodes in this arc tube design are moved down to the bottom of the arc tube. As the arc bows, it does not position itself as close to the top of the arc tube, thus assisting in improved lamp life. In addition, with the electrodes positioned lower, the pool of halides falls due to the gravity draw. They are now closer to the arc stream, which keeps the overall light output high. This design has resulted in many problems in lighting applications. Initially, engineers must be certain to specify the POM base and socket. Then, the manufacturer has to ensure that the POM socket is correctly installed in the fixture, and the proper HOR lamp with the POM base has to be ordered. Additionally, the pin and the channel on the socket must Position Oriented Mogul (POM) base and socket, align perfectly. All of which is NOT required for these elements rarely Venture’s H75 Series occur. Consequently, early failures, color shift and lumen miscalculations are common occurrences. Venture’s Horizontal Pulse Start Series is a practical and needed improvement to help alleviate these problems. H ORIZONTAL +/- 75°(H75) What makes Venture’s Horizontal Pulse Start systems so unique is the Uni-Form® arc tube. Venture Lighting understands the practical need to remove the POM base and socket requirement. In order to allow this to happen, Venture developed a way to keep the electrodes at the center of the arc tube at all times; the install positioning has now become irrelevant. Life The walls of the arc tube have been substantially thickened with quartz material. This allows for a more uniform heating of the upper side of the arc tube, which results in longer overall lamp life. Lumens Venture has also modified the Uni-Form arc tube shape to offer better lumens. The chemistry of the metal halide lamp’s arc tube has been changed to produce the lumens that meet the standard V or BU versions of the lamp. This has produced greater mean lumens in this product line. Dimming Capabilities For even greater energy savings, Venture Lighting’s Horizontal pulse start metal halide lamps can be step or bi-level dimmed by the switched capacitance method on a CWA or CWI ballast, or continuously dimmed on electronic ballasts. Lamps cannot be dimmed below 50% of the rated lamp wattage at 90% input voltage. Contact Venture Lighting for further information. V ENTURE L IGHTING ’ S H ORIZONTAL P ULSE S TART L AMPS Open Rated LAMPS ANSI Type-O Operating Position of Horizontal ± 75° Lamp Watts Description 250 MP 250W/H75/T15/UVS/PS/EM/950 Product No. 59324 ANSI Code M153/O Initial Lumens 17000 LLD 0.90 LPW 74 Rated Life (hrs) CCT 15000 5000K CRI 90+ Finish Clear Case Qty 12 MP 250W/H75/UVS/PS/740 49822 M153/O 21300 0.80 85 20000 4000K 68 Clear 12 MP 250W/H75/T15/UVS/PS/740 19252 M153/O 21300 0.80 85 20000 4000K 68 Clear 12 320 MP 320W/H75/T15/L/UVS/PS/EM/950 95321 M154/O 22500 0.90 76 26000 5000K 90+ Clear 12 MP 320W/H75/T15/S/UVS/PS/EM/950 95320 M154/O 22500 0.90 76 26000 5000K 90+ Clear 12 350 MP 350W/H75/UVS/PS/740 MP 350W/H75/T15/L/UVS/PS/740 400 MP 400W/H75/UVS/PS/740 MP 400W/H75/T15/L/UVS/PS/740 575 MP 575W/H75/T25/PS/740 65218 M131/O 32000 0.80 91 26000 4000K 68 Clear 6 51208 M131/O 32000 0.80 91 26000 4000K 68 Clear 12 17611 M155/O 38000 0.80 95 26000 4000K 68 Clear 6 73189 M155/O 38000 0.80 95 26000 4000K 68 Clear 12 56423 M178/O 55000 0.80 96 20000 4000K 68 Clear 6 Enclosed Rated LAMPS ANSI Type-E Operating Position of Horizontal ± 75° Lamp Watts Description 175 MS 175W/H75/PS/740 Product No. 99585 ANSI Code M152/E Initial Lumens 13000 LLD 0.80 LPW 74 Rated Life (hrs) CCT 15000 4000K CRI 68 Finish Clear Case Qty 12 99586 M152/E 13000 0.80 74 15000 4000K 68 Clear 12 60375 M136/E 19000 0.86 95 40000 4000K 68 Clear 12 MHL 200W/C/H75/ED28/PS/737 10237 M136/E 18100 0.86 91 40000 3700K 70 Coated 12 MS 200W/H75/T15/PS/740 70764 M136/E 19000 0.80 95 15000 4000K 68 Clear 12 65413 M153/E 22000 0.86 88 40000 4000K 68 Clear 12 MHL 250W/C/H75/ED28/PS/737 32393 M153/E 20900 0.86 84 40000 3700K 70 Coated 12 MS 250W/H75/PS/740 81054 M153/E 22000 0.80 88 20000 4000K 68 Clear 12 MS 250W/H75/T15/PS/740 57625 M153/E 22000 0.80 88 20000 4000K 68 Clear 12 20116 M154/E 30000 0.86 94 40000 4000K 68 Clear 12 11086 M154/E 28000 0.86 88 40000 3700K 70 Coated 12 MS 175W/H75/T15/PS/740 200 MHL 200W/H75/ED28/PS/740 250 MHL 250W/H75/ED28/PS/740 320 MHL 320W/H75/ED28/PS/740 MHL 320W/C/H75/ED28/PS/737 MHL 320W/H75/ED37/PS/740 28699 M154/E 30000 0.86 94 40000 4000K 68 Clear 6 MHL 320W/C/H75/ED37/PS/737 34778 M154/E 28000 0.86 88 40000 3700K 70 Coated 6 MS 320W/H75/ED28/PS/740 47549 M154/E 30000 0.80 94 26000 4000K 68 Clear 12 MS 320W/C/H75/ED28/PS/737 12758 M154/E 28000 0.80 88 26000 3700K 70 Coated 12 MS 320W/H75/T15/S/PS/740 57626 M154/E 30000 0.80 94 26000 4000K 68 Clear 12 MS 320W/H75/T15/L/PS/740 79710 M154/E 30000 0.80 94 26000 4000K 68 Clear 12 350 MHL 350W/H75/ED37/PS/740 MHL 350W/C/H75/ED37/PS/737 28700 M131/E 33000 0.86 94 40000 4000K 68 Clear 6 34779 M131/E 31000 0.86 89 40000 3700K 70 Coated 6 MHL 350W/H75/ED28/PS/740 20117 M131/E 33000 0.86 94 40000 4000K 68 Clear 12 MHL 350W/C/H75/ED28/PS/737 11087 M131/E 31000 0.86 89 40000 3700K 70 Coated 12 MS 350W/C/H75/PS/737 64866 M131/E 31000 0.80 89 26000 3700K 70 Coated 6 MS 350W/H75/ED28/PS/740 46959 M131/E 33000 0.80 94 26000 4000K 68 Clear 12 MS 350W/H75/T15/S/PS/740 60258 M131/E 33000 0.80 94 26000 4000K 68 Clear 12 MS 350W/H75/T15/L/PS/740 93749 M131/E 33000 0.80 94 26000 4000K 68 Clear 12 400 MHL 400W/H75/BT37/PS/740 15619 M155/E 40000 0.80 100 40000 4000K 68 Clear 6 MS 400W/H75/PS/740 58788 M155/E 40000 0.80 100 26000 4000K 68 Clear 6 MS 400W/H75/ED28/PS/740 40124 M155/E 40000 0.80 100 26000 4000K 68 Clear 12 MS 400W/C/H75/ED28/PS/737 55459 M155/E 38000 0.80 95 26000 3700K 70 Coated 12 MS 400W/H75/T15/S/PS/740 60260 M155/E 40000 0.80 100 26000 4000K 68 Clear 12 MS 400W/H75/T15/L/PS/740 74151 M155/E 40000 0.80 100 26000 4000K 68 Clear 12 575 MHL 575W/H75/BT37/PS/740 20897 M178/E 55000 0.80 96 40000 4000K 68 Clear 6 MHL 575W/H75/BT37/PS/EM/950 17921 M178/E 45000 0.90 82 40000 5000K 90+ Clear 6 MS 575W/H75/BT37/PS/EM/950 95577 M178/E 45000 0.90 82 20000 5000K 90+ Clear 6 775 MS 775W/H75/BT37/PS/950 24999 M181/E 60000 0.90 77 15000 5000K 90+ Clear 6 875 MHL 875W/H75/BT37/PS/740 56412 M166/E 90000 0.80 103 30000 4000K 68 Clear 6 74892 M166/E 90000 0.80 103 15000 4000K 68 Clear 6 MS 875W/H75/BT37/PS/740 NOTES: Natural White® lamp, 90 CRI, 0.90 LLD, 5000K CCT Super Pulse Start Long Life (SPL) 40,000 hour rated life lamp 2 V ENTURE L IGHTING ’ S H ORIZONTAL P ULSE S TART L AMPS C O M PA R E , S W I T C H A N D S Probe Horizontal System Total Annual Increased Start Pulse Start Watts Savings Light Fixture Upgrade Saved1 Per Fixture2 Levels3 AV E ! Increased Lamp Life in Hours 1000W 775W 235 $103 29% 6000 400W 400W 350W 320W 20 75 106 $9 39% 23% 14% 11000 11000 11000 250W 250W 200W 15 70 40% 47% 3750 3750 $33 $46 $7 $31 H75 L AMPS B ENEFITS • Longer life and higher lumen output compared to both HOR and universal lamps in horizontal operation • No POM base and socket required • Variety of tubular and elliptical outer jacket shapes and sizes for full cut-off fixtures Notes: Based on Horizontal Operation 1 Based on use of CWA ballasts for probe start systems and 277V reactor ballasts for Horizontal pulse start systems 2 Based upon 12 hours per day, $0.10 per kWh 3 Lumen depreciation compared at mean lumen point for pulse start lamps A PPLICATIONS • Parking Garages • Car Dealerships • Site Lighting • Wall Wash Applications • Gas Station Canopy • Area Lighting • Parking Lot Lighting ALSO S E E O U R O T H E R P U L S E S TA R T FA M I L I E S O F L I G H T I N G S Y S T E M S : S UPER P ULSE S TART Long Life (SPL) S UPER P ULSE S TART Ceramic (SPC) Extended Life Lamp Series Ceramic Metal Halide Venture’s Super Pulse Start Long Life lamp series delivers up to twice the rated life of many of our regular pulse start products Venture’s Super Pulse Start Ceramic lamps achieve warm crisp white light, high CRI and reveals vibrant colors. • 40,000 hours rated life • Superior Color Performance • Patent pending for long life • Best in Class Performance for Lumen Output, Color and Life • Quartz metal halide • 70W to 875W, Available in Universal, Vertical (±15°), Base-Up (±15°) and Horizontal (±75°) positions of operation See our brochure online • Warm, Crisp 3000K CCT, and Up to 90 CRI See our brochure online N ATURAL W HITE ® L EAF N UT ™ P ULSE S TART M ETAL H ALIDE L IGHTING S YSTEMS W IRELESS L IGHTING C ONTROL S YSTEM • The Color of Natural Sunlight: 5000K Achieve energy savings and reduce carbon emissions with Venture’s advanced intelligent wireless control system for area or street lighting. LeafNut™ system is a complete 24/7 web-based, easy-to-install, wireless communications control system. • See Clearer, Objects Appear Sharper, Colors Look Crisper • High CRI, 90+ Lighting • 90% Lumen Maintenance (0.90 LLD) See our brochure online See our brochure online (800) 451-2606 or (440) 248-3510 Fax: (800) 451-2605 7905 Cochran Road Glenwillow, Ohio 44139 USA E-mail: venture@adlt.com VentureLighting.com © 2014 Venture Lighting International Venture, Natural White and Uni-Form are trademarks or registered trademarks of Venture Lighting International. VLI-1119B1_v7-0814