TABLE OF CONTENTS Northern Lights Marine Generators & Sound Enclosures 2 Northern Lights Commercial Series Generators 10 Northern Lights Marine Generator Options & Accessories 12 Northern Lights Land-Based Generators 14 Footnotes18 The specifications in this document are subject to change without notice. Please note that dimensions and weights of generators are affected by optional equipment, AC output, phase (three phase or single phase may be options) and cooling configurations. Specifications of diesel propulsion engines and HVAC equipment are similarly affected by options and other factors. Please contact the factory for special applications and de-rating factors. www.northern-lights.com Contact factory for installation drawings. Northern Lights® generators, Lugger® marine engines, and Technicold® marine systems are manufactured by Northern Lights, Inc. 4420 14th Avenue Northwest • Seattle, WA 98107-4616 Tel: (206) 789-3880 • (800) 762-0165 • Fax: (206) 782-5455 Web: www.northern-lights.com • E-mail: info@northern-lights.com Northern Lights, Technicold and Lugger are registered trademarks of Northern Lights Incorporated ©2016 Information, specifications, materials and dimensions subject to change without notice. ©2016 All Rights Reserved. Litho in USA. L605 MARINE GENERATORS Marine Power Generation Northern Lights manufactures a comprehensive line of 50 and 60 Hz marine generator sets from 4.5 to 545 kW. Powered by rugged Lugger diesels and proven in commercial fishing boats, high-performance yachts and passenger vessels, Northern Lights generators provide unmatched quality and reliability. M773LW3 7 - 9 kW 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M673L3 (1, 2) 6 kW 5 kW 3 inline 2.6/2.8 in (67/72 mm) 46.4 cid (0.76 ltr) Mechanical Natural Tier III 28.5 x 19.5 x 20.1 28.5 x 19.5 x 20.8 724 x 495 x 510 724 x 495 x 528 377 lbs (171 kg) 421 lbs (191 kg) 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M773LW3 (1, 2) 9 kW 7 kW 3 inline 3.0/3.2 in (77/81 mm) 69 cid (1.13 ltr) Mechanical Natural Tier III 35.0 x 22.0 x 23.8 35.0 x 22.0 x 24.2 889 x 559 x 604 889 x 559 x 614 537 lbs (244 kg) 597 lbs (271 kg) M673LD3 (1, 2) 5 kW 4.5 kW 3 inline 2.6/2.8 in (67/72 mm) 46.4 cid (0.76 ltr) Mechanical Natural Tier III 28.5 x 19.5 x 20.1 28.5 x 19.5 x 20.8 724 x 495 x 510 724 x 495 x 528 377 lbs (171 kg) 421 lbs (191 kg) M843NW3 (1, 2) 12 kW 10 kW 3 inline 3.3/3.5 in (84/90 mm) 91 cid (1.5 ltr) Mechanical Natural Tier III 39.4 x 22.8 x 25.2 39.4 x 22.8 x 25.7 1000 x 580 x 641 1000 x 580 x 654 837 lbs (380 kg) 912 lbs (414 kg) * For 60 Hz Units only. US EPA Marine Tier III certified units are available globally. US EPA Marine Tier II units are available for non-US flagged vessels only. 2 MARINE GENERATORS 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M844DW3 (1, 2) 16 kW 14 kW 4 inline 3.3/3.9 in (84/100 mm) 135 cid (2.2 ltr) Mechanical Natural Tier III 46.0 x 22.8 x 27.5 46.0 x 22.8 x 28.1 1169 x 580 x 697 1169 x 580 x 714 973 lbs (441 kg) 1063 lbs (482 kg) M944W (1, 2) 60 Hz/1800 rpm: N/A M844LW3 (1, 2) 20 kW 16 kW 4 inline 3.3/3.9 in (84/100 mm) 135 cid (2.2 ltr) Mechanical Natural Tier III 46.0 x 22.8 x 27.5 46.0 x 22.8 x 28.1 1169 x 580 x 697 1169 x 580 x 714 973 lbs (441 kg) 1098 lbs (498 kg) M864W3 (1, 2) 25 kW 20 kW 4 inline 3.4/4.2 in (86/107 mm) 152 cid (2.49 ltr) Mechanical Natural Tier III 52.9 x 24.2 x 26.5 52.9 x 24.2 x 27.7 1350 x 696 x 672 1350 x 696 x 703 993 lbs (450 kg) 1133 lbs (514 kg) M944T (1, 2) 38 kW M944T3 (1) 40 kW, three phase 38 kW, single phase 50 Hz/1500 rpm: 26 kW 32 kW n/a Cylinders: 4 inline 4 inline 4 inline Bore/Stroke: 3.7/4.7 in (94/120 mm) 3.7/4.7 in (94/120 mm) 3.7/4.7 in (94/120 mm) Displacement: 203 cid (3.33 ltr) 203 cid (3.33 ltr) 203 cid (3.33 ltr) Fuel System: Mechanical Direct Injection Direct Injection Aspiration: Natural Turbocharged Turbocharged US EPA Level*: Tier II Tier II Tier III L x W x H (in): 56.0 x 29.0 x 30.7 60.0 x 29.0 x 30.5 60.0 x 29.0 x 30.5 w/Enclosure: 56.0 x 29.0 x 31.5 60.0 x 29.0 x 32.0 60.0 x 29.0 x 32.0 L x W x H (mm): 1422 x 737 x 779 1524 x 736 x 775 1524 x 736 x 775 w/Enclosure: 1422 x 737 x 800 1524 x 736 x 813 1524 x 736 x 813 Weight: 1351 lbs (604 kg) 1443 lbs (654 kg) 1416 lbs (642 kg) w/Enclosure: 1509 bs (676 kg) 1583 lbs (706 kg) 1556 bs (706 kg) 3 MARINE GENERATORS 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M1064DL 40 kW 33 kW 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) Rotary Mechanical Natural Tier II 75.0 x 38.0 x 38.2 75.0 x 38.0 x 40.9 1905 x 965 x 970 1905 x 965 x 1039 2513 lbs (1140 kg) 6 2849 lbs (1292 kg) 6 M50T13L (3) 50 kW N/A 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbocharged Tier III 75.0 x 38.0 x 39.2 75.0 x 38.0 x 41 1905 x 965 x 997 1905 x 965 x 1040 2315 lbs (1050 kg) 6 2471 lbs (1123 kg) M1064T1 55 kW 50 kW 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) Rotary Mechanical Turbocharged Tier II 75.0 x 38.0 x 38.2 75.0 x 38.0 x 40.9 1905 x 965 x 970 1905 x 965 x 1039 2513 lbs (1140 kg) 6 2849 lbs (1292 kg) 6 Engineered for Silence Northern Lights’ industry-leading sound enclosures provide exceptionally quiet operation. Dual sound-dampening barriers ensure optimum sound absorption. Advanced damper-sheet-coated internal air ducting keeps your generator quiet and cool - even in the warmest environments. The advanced construction features rigid, powder-coated aluminum or electro-galvanized steel, making the enclosure extraordinarily robust, resistant to corrosion, and an aesthetic complement any engine room. • Secure, easy to reach latches on top and front. • Stainless steel paddle latch on service side. • Interior latches on non-service sides improve aesthetics. • Multiple layers of firm and flexible sound dampening materials absorb all frequency noise. • Protective film coating ensures safety and longevity. • Fuel and oil drains outside of the sound enclosure for easy connection. • Front exhaust exit option. • Tough, white, powder-coat finish. * For 60 Hz Units only. US EPA Marine Tier III certified units are available globally. US EPA Marine Tier II units are available for non-US flagged vessels only. 4 MARINE GENERATORS 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M1064T2 (3) 65 kW 55 kW 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) Electronic DE10 Turbocharged Tier II 75.0 x 38.0 x 38.2 75.0 x 38.0 x 40.9 1905 x 965 x 970 1905 x 965 x 1039 2603 lbs (1181 kg) 6 2939 lbs (1333 kg) 6 M65T13L (3) 65 kW N/A 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbocharged Tier III 75.0 x 38.0 x 39.2 75.0 x 38.0 x 40.9 1905 x 965 x 997 1905 x 965 x 1040 2594 lbs (1177 kg) 6 3086 lbs (1401 kg) 6 M80A13L (3) 80 kW N/A 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbo & Aftercooled Tier III 75.0 x 38.0 x 39.4 75.0 x 38.0 x 40.9 1905 x 965 x 1001 1905 x 965 x 1040 3107 lbs (1409 kg) 6 3599 lbs (1632 kg) 6 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M1064AL (3) 92 kW 70 kW 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) Electronic DE 10 Turbo & Aftercooled Tier II 77.5 x 38.0 x 38.4 77.5 x 38.0 x 40.9 1960 x 965 x 975 1969 x 965 x 1039 2750 lbs (1248 kg) 6 3086 lbs (1400 kg) 6 M1066TL (3) 99 kW 80 kW 6 inline 4.2/5.0 in (106/127 mm) 414 cid (6.8 ltr) Rotary Electric Turbocharged Tier II 81.0 x 42.0 x 41.5 CF x 38.0 x 41.0 2058 x 1066 x 1054 CF x 965 x 1041 2886 lbs (1306 kg) 6 Consult Factory M1064HL (3) 99 kW 90 kW 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbo & Aftercooled Tier III 75.0 x 38.0 x 38.4 75.0 x 38.0 x 40.9 1905 x 965 x 975 1905 x 965 x 1039 2750 lbs (1247.5 kg) 6 3086 lbs (1399.5 kg) 6 * For 60 Hz Units only. US EPA Marine Tier III certified units are available globally. US EPA Marine Tier II units are available for non-US flagged vessels only. 5 MARINE GENERATORS 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M1066A13L (3,5) 120 kW N/A 6 inline 4.2/5.0 in (106/127 mm) 414 cid (6.8 ltr) Electronic HPCR Turbo & Aftercooled Tier III 90.0 x 42.0 x 41.5 90.0 x 42.0 x 42.0 4 2286 x 1067 x 1054 2286 x 1067 x 1067 4 3630 lbs (1646 kg) 6 4066 lbs (1844 kg) 6 M150A13 (3,5) 150 kW 125 kW 6 inline 4.2/5.0 in (106/127 mm) 414 cid (6.8 ltr) Electronic HPCR Turbo & Aftercooled Tier III 90.0 x 42.0 x 41.5 90.0 x 42.0 x 42.0 4 2286 x 1067 x 1054 2286 x 1067 x 1067 4 3750 lbs (1700 kg) 6 4186 lbs (1900 kg) 6 M1066HL3(3,5) 185 kW 155 kW 6 inline 4.2/5.0 in (106/127 mm) 414 cid (6.8 ltr) Electronic HPCR Turbo & Aftercooled Tier III 90.0 x 42.0 x 41.5 90.0 x 42.0 x 42.0 4 2286 x 1067 x 1054 2286 x 1067 x 1067 4 3630 lbs (1646 kg) 6 4066 lbs (1844 kg) 6 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M1305A12 (3,5) 185 kW 185 kW 5 inline 5.1/5.5 in (130/140 mm) 567 cid (9.3 ltr) PDE Unit Injectors Turbo & Aftercooled Tier II 86.4 x 40.2 x 49.2 107.0 x 56.0 x 55.0 2200 x 1020 x 1250 2720 x 1420 x 1400 4690 lbs (2130 kg) 6055 lbs (2780 kg) 7 M1305A22 (3,5) 200 kW 200 kW 5 inline 5.1/5.5 in (130/140 mm) 567 cid (9.3 ltr) PDE Unit Injectors Turbo & Aftercooled Tier II 89.9 x 40.2 x 49.2 107.0 x 56.0 x 55.0 2290 x 1020 x 1250 2720 x 1420 x 1400 4900 lbs (2240 kg) 6265 lbs (2860 kg) 7 M1305A32 (3,5) 250 kW 250 kW 5 inline 5.1/5.5 in (130/140 mm) 567 cid (9.3 ltr) PDE Unit Injectors Turbo & Aftercooled Tier II 94.9 x 40.2 x 49.2 107.0 x 56.0 x 55.0 2410 x 1020 x 1250 2720 x 1420 x 1400 5480 lbs (2490 kg) 6 6845 lbs (3110 kg) 7 * For 60 Hz Units only. US EPA Marine Tier III certified units are available globally. US EPA Marine Tier II units are available for non-US flagged vessels only. 6 MARINE GENERATORS 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M1306A13 (3,5) 250 kW N/A 6 inline 5.1/6.3 in (130/160 mm) 775 cid (12.7 ltr) PDE Unit Injectors Turbo & Aftercooled Tier III 111.0 x 42.0 x 47.1 Consult Factory 2819 x 1067 x 1196 Consult Factory 6350 lbs (2880 kg) 6 Consult Factory M1305A42 (3,5) 300 kW N/A 5 inline 5.1/5.5 in (130/140 mm) 567 cid (9.3 ltr) PDE Unit Injectors Turbo & Aftercooled Tier II 94.9 x 40.2 x 49.2 107.0 x 56.0 x 55.0 2410 x 1020 x 1250 2720 x 1420 x 1400 5480 lbs (2490 kg) 6 6845 lbs (3110 kg) 7 M1306A23 (3,5) 300 kW N/A 6 inline 5.1/6.3 in (130/160 mm) 775 cid (12.7 ltr) PDE Unit Injectors Turbo & Aftercooled Tier III 111.0 x 42.0 x 47.1 Consult Factory 2819 x 1067 x 1196 Consult Factory 6350 lbs (2880 kg) 6 Consult Factory 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M1306A33 (3,5) 350 kW N/A 6 inline 5.1/6.3 in (130/160 mm) 775 cid (12.7 ltr) PDE Unit Injectors Turbo & Aftercooled Tier III 111.0 x 42.0 x 47.1 Consult Factory 2819 x 1067 x 1196 Consult Factory 6350 lbs (2880 kg) 6 Consult Factory M1306A12 (3) 355 kW 300 kW 6 inline 5.12/6.3 in (130/160 mm) 775 cid (12.7 ltr) PDE Unit Injectors Turbo & Aftercooled Tier II 107.0 x 38.6 x 52.6 119.0 x 56.0 x 55.0 2720 x 981 x 1340 3010 x 1420 x 1400 6350 lbs (2880 kg) 6 7846 lbs (3561 kg) 7 M1306A22 (3,5) 400 kW 350 kW 6 inline 5.12/6.3 in (130/160 mm) 775 cid (12.7 ltr) PDE Unit Injectors Turbo & Aftercooled Tier II 107.0 x 38.6 x 52.6 119.0 x 56.0 x 55.0 2720 x 981 x 1340 3010 x 1420 x 1400 6670 lbs (3025 kg) 6 8166 lbs (3706 kg) 7 * For 60 Hz Units only. US EPA Marine Tier III certified units are available globally. US EPA Marine Tier II units are available for non-US flagged vessels only. 7 MARINE GENERATORS 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M1306A43 (3,5) 396 kW N/A 6 inline 5.1/6.3 in (130/160 mm) 775 cid (12.7 ltr) PDE Unit Injectors Turbo & Aftercooled Tier III 111.0 x 42.0 x 47.1 Consult Factory 2819 x 1067 x 1196 Consult Factory 6350 lbs (2880 kg) 6 Consult Factory M1306A22 (3,5) N/A 400 kW 6 inline 5.12/6.3 in (130/160 mm) 775 cid (12.7 ltr) PDE Unit Injectors Turbo & Aftercooled Tier II 107.0 x 38.6 x 52.6 119.0 x 56.0 x 55.0 2720 x 981 x 1340 3010 x 1420 x 1400 6700 lbs (3040 kg) 6 8196 lbs (3721 kg) 7 M1308A22 (3,5) 475 kW 420 kW V-8 5.1/6.1 in (130/154 mm) 1001 cid (16.4 ltr) PDE Unit Injectors Turbo & Aftercooled Tier II 106.0 x 48.2 x 68.6 Consult Factory 2683 x 1224 x 1742 Consult Factory 7590 lbs (3450 kg) Consult Factory 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): w/Enclosure: L x W x H (mm): w/Enclosure: Weight: w/Enclosure: M1308A33 (3,5) 485 kW N/A V-8 5.1/6.1 in (130/154 mm) 1001 cid (16.4 ltr) PDE Unit Injectors Turbo & Aftercooled Tier III 106.0 x 48.2 x 68.6 Consult Factory 2683 x 1224 x 1742 Consult Factory 5790 lbs (3450 kg) Consult Factory M1308A43 (3,5) 514 kW N/A V-8 5.1/6.1 in (130/154 mm) 1001 cid (16.4 ltr) PDE Unit Injectors Turbo & Aftercooled Tier III 112 x 48.2 x 68.6 Consult Factory 2847 x 1224 x 1742 Consult Factory 7880 lbs (3580 kg) Consult Factory M1308A42 (3,5) 545 kW 475 kW V-8 5.1/6.1 in (130/154 mm) 1001 cid (16.4 ltr) PDE Unit Injectors Turbo & Aftercooled Tier II 112 x 48.2 x 68.6 Consult Factory 2847 x 1224 x 1742 Consult Factory 7880 lbs (3580 kg) Consult Factory * For 60 Hz Units only. US EPA Marine Tier III certified units are available globally. US EPA Marine Tier II units are available for non-US flagged vessels only. 8 MARINE GENERATORS Radiator Cooled, Deck Mounted Sets 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): L x W x H (mm): Weight: 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: L x W x H (in): L x W x H (mm): Weight: M844LW3R 18 kW 15 kW 4 inline 3.3/3.9 in (84/100 mm) 135 cid (2.2 ltr) Mechanical Natural Tier III 55.2 x 30.0 x 40.0 1401 x 736 x 914 1132 lbs (513 kg) M944T3R 36 kW n/a 4 inline 3.7/4.7 in (94/120 mm) 203 cid (3.33 ltr) Mechanical Turbocharged Tier III Consult Factory Consult Factory Consult Factory M1064H.2SR (3) 99 kW N/A 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbo & Aftercooled Tier III Consult Factory Consult Factory Consult Factory M150A13R (3) 150 kW 120 kW 4 inline 4.2/5.0 in (106/127 mm) 414 cid (6.8 ltr) HPCR Turbo & Aftercooled Tier III 104.4 x 35.3 x 53.0 2652 x 897 x 1346 3904 lbs (1770 kg) M1064T13R (3) 60 kW 50 kW 4 inline 4.2/5.0 in (106/127 mm) 246 cid (4.5 ltr) HPCR Turbocharged Tier III 82.1 x 30.0 x 43.0 2084 x 762 x 1092 2136 lbs (969 kg) * For 60 Hz Units only. US EPA Marine Tier III certified units are available globally. US EPA Marine Tier II units are available for non-US flagged vessels only. 9 C-SERIES MARINE GENERATORS C-Series Power for Commercial Challenges Northern Lights’ C-Series generator sets are designed for tough commercial applications. These generators deliver the rugged durability, long-life dependability and the peace of mind that comes with owning a Northern Lights. M40C3 40 / 38 kW M40C3 (8) 60 Hz/1800 rpm: 40 kW, three phase 38 kW, single phase 50 Hz/1500 rpm: N/A Cylinders: 4 inline Bore/Stroke: 3.7/4.7 in (94/120 mm) Displacement: 202 cid (3.3 ltr) Fuel System: Mechanical Aspiration: Turbocharged US EPA Certified*: Tier III Length: 59.7 in (1517 mm) Width: 26.2 in (666 mm) Height: 34.2 in (870 mm) Weight: 1332 lbs (604 kg) 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Certified*: Length: Width: Height: Weight: M20CRW3 (8) 20 kW 16 kW 4 inline 3.3/3.9 in (84/100 mm) 135 cid (2.2 ltr) Mechanical Natural Tier III 43.2 in (1098 mm) 20.7 in (526 mm) 32.8 in (833 mm) 820 lbs (372 kg) M50C13 (8) 50 kW M55C13 (8) 55 kW N/A 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbocharged Tier III 64.9 in (1648 mm) 28.0 in (711 mm) 39.8 in (1011 mm) 2072 lbs (940 kg) N/A 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbocharged Tier III 64.9 in (1648 mm) 28.0 in (711 mm) 39.8 in (1011 mm) 2072 lbs (940 kg) * US EPA Tier 3 Marine certified units are available globally. US EPA Tier 2 Marine Certified units are available for non-US flagged vessels only. 10 C-SERIES MARINE GENERATORS 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Certified*: Length: Width: Height: Weight: M65C13 (8) 65 kW 55 kW 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbocharged Tier III 64.9 in (1648 mm) 28.0 in (711 mm) 39.8 in (1011 mm) 2072 lbs (940 kg) M99C13 (8) 99 kW 80 kW 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbo & Aftercooled Tier III 69.2 in (1757 mm) 30.4 in (771 mm) 43.0 in (1092 mm) 2565 in (1164 mm) 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Certified*: Length: Width: Height: Weight: M200C13 (8) 200 kW 175 kW 6 inline 4.6/5.0 in (118/127 mm) 549 cid (9.0 ltr) HPCR Turbo & Aftercooled Tier III 97.5 in (2745 mm) 37.3 in (947 mm) 45.5 in (1156 mm) 4263 in (1935 mm) M250C13 (8) 250 kW Consult Factory 6 inline 4.6/5.0 in (118/127 mm) 549 cid (9.0 ltr) HPCR Turbo & Aftercooled Tier III 102.5 in (2745 mm) 36.0 in (914 mm) 44.8 in (1138 mm) 4640 lbs (2104 kg) M150C3 (8) 150 kW 6 inline 4.2/5.0 in (106/127 mm) 414 cid (6.8 ltr) HPCR Turbo & Aftercooled Tier III 83.1 in (2111 mm) 33.8 in (858 mm) 41.6 in (1056 mm) 3550 lbs (1610 kg) * US EPA Tier 3 Marine certified units are available globally. US EPA Tier 2 Marine Certified units are available for non-US flagged vessels only. 11 OPTIONS AND ACCESSORIES World Class Options and Accessories Northern Lights offers the most complete line of accessories in the industry. From high output battery charging alternators to compound mounts, Northern Lights’ comprehensive list of options and decades of experience with custom configurations is unmatched. 12 or 24-volt, single or three phase, wet or dry exhaust, heat exchanged or keel cooled, Northern Lights offers it! Let Northern Lights build a generator to your specifications at the factory. You’ll save time and money by avoiding expensive modifications in the field. Northern Lights builds generators with options to comply with a variety of classification societies. To learn more about our line of world class options, download our Accessories brochure. After Treatment Solutions Northern Lights ensures clean power solutions. We offer DPF and SCR solutions that help meet emission and society requirements. Northern Lights’ revolutionary DECS virtually eliminates soot from diesel marine engine exhaust. Our SCR solutions convert NOx emissions into harmless N2 and Oxygen. Consult your Factory Representative for a bespoke solution that is best suited to your vessel. 12 OPTIONS AND ACCESSORIES Compound Mounts Northern Lights units come equipped with the industry’s best vibration mounts, supplied as standard equipment. To further minimize generator set vibration, Northern Lights is proud to offer Compound Mounts. Optimal attenuation is achieved through the use of industrial grade rubber and galvanized steel - components tough enough for the marine environment. Fitting beneath the base frame, NL Compound Mounts add mere centimeters to the height of the generator set, ensuring engine room space is not sacrificed for attenuation. TSCM Controller Looking for a truly intuitive controller for your marine generator set? Look no further than the TSCM Tough Series controller. With a backlit LCD screen and large easy to read push buttons, TSCM is engine-room ready. TSCM puts engine and electrical data at your fingertips. Available RS485 and J1939 protocols connect to a remote monitoring system. TSCM is versatile enough to permit remote monitoring and control connections through a single data and power cable, up to 30 meters in length. 13 LAND-BASED GENERATORS Land-Based Power Generation Northern Lights manufactures a comprehensive line of prime and stand-by diesel industrial generators from 5 kW to 400 kW. Fifty years ago, Northern Lights generators were developed to provide life-sustaining power in the Alaskan wilderness. They became renowned for outstanding reliability in schools, villages and during pipeline construction. Today, Northern Lights handles the toughest challenges for prime and stand-by power. Northern Lights generator sets up to 12 kW are Tier IV approved, and all land based units are US EPA compliant ensuring clean, reliable production. No matter whether on a job site, a hunting camp, or a remote telecommunications station, Northern Lights offers the superior engineering and technical precision to bring you reliable power. Project-tailored designs and special fabrication options are available for power modules, trailer units and more. Consult factory for additional, off-shore only, items. 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: Length: Width: Height: Weight: NL673L4 (9) 5 kW 4.5 kW 3 inline 2.6/2.8 in (67/72 mm) 46 cid (0.76 ltr) Mechanical Natural Tier IV 32.8 in (834 mm) 17.1 in (435 mm) 26.8 in (650 mm) 390 lbs (178 kg) NL673L4E (9) 6 kW N/A 3 inline 2.6/2.8 in (67/72 mm) 46 cid (0.76 ltr) Electronic Natural Tier IV 32.8 in (834 mm) 17.1 in (435 mm) 26.8 in (650 mm) 390 lbs (178 kg) * For 60 Hz Units only. US EPA Tier IV certified units are available globally. US EPA Tier II & Tier III units are available for non-US applications only. 14 NL773LW4 (9) 8 kW 6.5 kW 3 inline 3.0/3.2 in (77/81 mm) 69 cid (1.13 ltr) Mechanical Natural Tier IV 37.9 in (965 mm) 20.4 in (520 mm) 31.3 in (797 mm) 551 lbs (250 kg) LAND-BASED GENERATORS NL773LW4E 9 - 7 kW 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: Length: Width: Height: Weight: 60 Hz/1800 rpm: 50 Hz/1500 rpm: Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: Length: Width: Height: Weight: NL773LW4E (9) 9 kW N/A 3 inline 3.0/3.2 in (77/81 mm) 69 cid (1.13 ltr) Electronic Natural Tier IV 37.9 in (965 mm) 20.4 in (520 mm) 31.3 in (797 mm) 556 lbs (252 kg) NL843NW4 (9) 12 kW 10 kW 3 inline 3.3/3.5 in (84/90 mm) 91 cid (1.5 ltr) Mechanical Natural Tier IV 45.7 in (1060 mm) 18.1 in (461 mm) 33.1 in (841 mm) 668 lbs (303 kg) NL844TE (9) 22 kW N/A 4 inline 3.3/3.9 in (84/100 mm) 135 cid (2.2 ltr) Electronic Turbo Tier IV 55.3 in (1400 mm) 26.5 in (670 mm) 36.5 in (925 mm) 1275 lbs (580 kg) NL844TE 22 kW * For 60 Hz Units only. US EPA Tier IV certified units are available globally. US EPA Tier II & Tier III units are available for non-US applications only. 15 STAND BY LAND-BASED GENERATORS Prime (60 Hz): Standby (60 Hz): Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: Length: Width: Height: Weight: NL944D3 (9) 28 kW 24 kW 4 inline 3.7/4.7 in (94/120 mm) 203 cid (3.33 ltr) Mechanical Natural Part 60 64.8 in (1647 mm) 25.6 in (650 mm) 35.7 in (907 mm) 1316 lbs (600 kg) Prime (60 Hz): Standby (60 Hz): Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: Length: Width: Height: Weight: NL944T3 (9) 36 kW 32 kW 4 inline 3.7/4.7 in (94/120 mm) 203 cid (3.33 ltr) Mechanical Turbocharged Part 60 64.8 in (1647 mm) 25.6 in (650 mm) 35.8 in (910 mm) 1390 lbs (630 kg) NL1064T23 (10) N/A 54 kW 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) Rotary Mechanical Turbocharged Part 60 77.5 in (1967 mm) 28.0 in (711 mm) 57.0 in (1448 mm) 1960 lbs (888 kg) * For 60 Hz Units only. US EPA Tier IV certified units are available globally. US EPA Tier II & Tier III units are available for non-US applications only. 16 NL1064H23 (10) N/A 85 kW 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbo & Charged Air Part 60 85.6 in (2174 mm) 30.5 in (775 mm) 52.2 in (1325 mm) 2800 lbs (1270 kg) STAND BY LAND-BASED GENERATORS Prime (60 Hz): Standby (60 Hz): Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: Length: Width: Height: Weight: NL1064H33 (10) N/A 100 kW 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbo & Charge Air Part 60 85.6 in (2174 mm) 30.5 in (775 mm) 52.2 in (1325 mm) 2900 lbs (1315 kg) NL1064H43 (10) N/A 125 kW 4 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbo & Aftercooled Part 60 85.6 in (2174 mm) 30.5 in (775 mm) 53.6 in (1361 mm) 3016 lbs (1368 kg) NL1066H23 (10) N/A 150 kW 6 inline 4.2/5.0 in (106/127 mm) 276 cid (4.5 ltr) HPCR Turbo & Aftercooled Part 60 102.2 in (2595 mm) 40.1 in (1019 mm) 54.7 in (1389 mm) 3385 lbs (1535 kg) Prime (60 Hz): Standby (60 Hz): Cylinders: Bore/Stroke: Displacement: Fuel System: Aspiration: US EPA Level*: Length: Width: Height: Weight: NL1066H33 (10) N/A 200 kW 6 inline 4.2/5.0 in (106/127 mm) 414 cid (6.8 ltr) HPCR Turbo & Aftercooled Part 60 112.7 in (2851 mm) 50.5 in (1285 mm) 66.2 in (1682 mm) 4106 lbs (1862 kg) NL1186H43 (10) N/A 275 kW 6 inline 4.7/5.4 in (118/126 mm) 548 cid (9.0 ltr) HPCR Turbo & Aftercooled Part 60 116.0 in (2946 mm) 48.0 in (1219 mm) 64.7 in (1643 mm) 4980 lbs (2259 kg) NL1326H N/A 400 kW 6 inline 5.2/6.5 in (132/165 mm) 824 cid (13.5 ltr) Electronic Unit Injection Turbo & Aftercooled Tier III Consult Factory Consult Factory Consult Factory Consult Factory * For 60 Hz Units only. US EPA Tier IV certified units are available globally. US EPA Tier II & Tier III units are available for non-US applications only. 17 FOOTNOTES Footnotes: 1. Prime kW rating based on SAE J-1995 and ISO 3046. Single-phase, 1.0 power factor, except where noted. 2. Lloyd’s Register of Shipping Type Approved. 3. Features electronic fuel injection and an electronic control unit (ECU). 4. Classed sound enclosure available. Inquire with factory. 5. Prime kW rating for standard three-phase generators at 0.8 power factor. Dimensional data is for units with hydrolastic mounts, heat exchanger cooling, and three-phase generator ends with PMG. Consult factory for dimensions on single phase and additional options. 6. Approximate dry weight based on Heat-exchanger cooling, 60 Hz, 3 phase unit. Consult factory for other applications. 7. Weight includes optional enclosure base plate. Consult factory for options required on your application. 8. Prime kW ratings for standard three-phase generators at 0.8 power factor, except where noted. Dimensional information is based on standard 1800 rpm, 60 Hz, three-phase generators with standard mounts. 9. Ratings based on SAE J-1995 at 1.0 unity power factor. 10. Ratings for three-phase units with 0.8 power factor. 11. Non-EPA Certified. Not for sale in the US. Founded in 1958, Northern Lights is a global leader of marine and land-based systems, offering a comprehensive line of marine and land-based generator sets as well as propulsion engines, and the Technicold line of marine cooling products. Based in Seattle, Washington, USA, Northern Lights is dedicated to delivering reliability, durability, and simplicity. With a worldwide dealer network in over 40 countries, support is never far away. 18 FOOTNOTES Founded in 1958, Northern Lights is a global leader of marine and land-based systems, offering a comprehensive line of marine and land-based generator sets as well as propulsion engines, and the Technicold line of marine cooling products. Based in Seattle, Washington, USA, Northern Lights is dedicated to delivering reliability, durability, and simplicity. With a worldwide dealer network in over 40 countries, support is never far away. 18 LOAD BANKS & AIR PURIFICATION SYSTEM The Technicold Contactor Load Bank supplies a supplemental electrical load to your marine generator set in stages up to 48 kW, ensuring that your set is always optimally loaded. All Technicold load banks include PLC controller with color touch screen panel, heat transfer module, raw water pump, circulation pump and expansion tank. LB48CDC Voltage: 208 Phase: 3 Hz: 50/60 LB48CDE 380 3 50/60 LB48CDJ 400 3 50/60 Smaller kW ranges and larger capacity units available. Consult factory for the solution for your individual application. AIR PURIFICATION SYSTEM NauticAir’s air purification system combines UV light with TiO2, resulting in the elimination of harmful airborne contaminants. Exterior of box wrapped in marine insulation • Interior of box coated with TiO2 • Weight 4 lbs • Dimensions 16” L x 8” H • Aluminum structure & hardware • Made to fix existing duct work • UV bulb with chamber to process air • Third-Party green certified TiO2 • • Fixed fan blades create more turbulence and contact time with UV & TiO2 Customized Options Available. Contact factory for details 17 Water cooled units. 1/5 HP = 115 VAC. 1.2 - 1.0 HP = 115 or 230 VAC Water cooled units. 1/5 HP = 115 VAC. 1.2 - 1.0 HP = 115 or 230 VAC 16 REFRIGERATION CONDENSING UNITS 404A refrigerant2 RB020AWA-404A Consult Factory RB050AWA-404A 14.5 in (368 mm) 13.5 in (343 mm) 12.5 in (317 mm) 73 lbs (33 kg) RB075AWA-404A 14.5 in (368 mm) 13.5 in (343 mm) 13.5 in (343 mm) 95 lbs (43 kg) RB100AWA-404A Consult Factory 134A refrigerant1 RB020AWA-134A Consult Factory RB050AWA-134A 14.5 in (368 mm) 13.5 in (343 mm) 12.5 in (317 mm) 73 lbs (33 kg) RB075AWA-134A 14.5 in (368 mm) 13.5 in (343 mm) 13.5 in (343 mm) 95 lbs (43 kg) RB100AWA-134A Consult Factory Model (1/5 hp): Dimensions: Model (1/2 hp): Height: Width: Depth: Weight: Model (3/4 hp): Height: Width: Depth: Weight: Model (1 hp): Dimensions: 404A refrigerant2 RB020WA-404A Consult Factory RB050WA-404A 14.5 in (368 mm) 13.5 in (343 mm) 12.5 in (317 mm) 73 lbs (33 kg) RB075WA-404A 14.5 in (368 mm) 13.5 in (343 mm) 13.5 in (343 mm) 95 lbs (43 kg) RB100WA-404A Consult Factory 134A refrigerant1 RB020WA-134A Consult Factory RB050WA-134A 14.5 in (368 mm) 13.5 in (343 mm) 12.5 in (317 mm) 73 lbs (33 kg) RB075WA-134A 14.5 in (368 mm) 13.5 in (343 mm) 13.5 in (343 mm) 95 lbs (43 kg) RB100WA-134A Consult Factory Model (1/5 hp): Dimensions: Model (1/2 hp): Height: Width: Depth: Weight: Model (3/4 hp): Height: Width: Depth: Weight: Model (1 hp): Dimensions: Customized Options Available. Contact factory for details DUCTS AND PUMPS Round Duct Rings w/Square Base MODELCircumference 6” HA6P 5” HA5P 4” HA4P Application RA8 RA12-RA32 RA12-RA32 Insulated Hose Ducts - 25’ length; R4.2 MODELCircumference 8” HCID-8 7” HCID-7 6” HCID-6 5” HCID-5 4” HCID-4 Centrifugal Water Pumps - Non-metallic housing MODELGPM 80 TE5000 54 TE3000 54 TE2000 28 TE1500 16 TE1000B 16 TE1000A 8 TE500B 8 TE500A 5 TE250B 5 TE250A Voltage 115 230 115 230 115 230 115/230 115/230 115/230 Centrifugal water pump 115/230 Consult factory for pump sizing. Customized Options Available. Contact factory for details 15 CHILLER ACCESSORIES Technicold offers an industry-best line up of accessories and optional equipment for your chilled water air conditioning system. Add heat function to your existing AC system, with Technicold immersion heat. Available in single or three phase options, our immersion heaters are fully insulated and are equipped with flow switches and high temperature shutdowns. Combine heaters for multi-staged solutions. DH500VC Three 2 500 DH500VB Phase: Single kW: 2 CFM: 500 HRS-12 Single 12 In-line HR-6 Phase: Single kW: 6 Config. In-line 14 HRP-12 Single 12 Parallel HR-9 Three 9 Inline Immersion Heater HRS-12 HR-18 Three 18 Inline HR-24 Three 24 Inline Harsh environments require creative solutions. That’s the reason Technicold offers industry best dash heaters with high velocity blowers. Constructed of stainless steel for longlife effectiveness, our 500-cfm dash heaters come with electric heat strips and high temp shutdowns standard. Customized Options Available. Contact factory for details DIRECT EXPANSION REMOTE EVAPORATORS 16,000 BTU 1 RE16A RE16B 15.0 amps 15.0 in (381 mm) 14.0 in (343 mm) 10.0 in (254 mm) 66 lbs (30 kg) Model (115 v): (230 v): Draw: Height: Width: Depth: Weight: 8,000 BTU 1 RE08A RE08B 8.9 amps 9.5 in (241 mm) 13.0 in (330 mm) 13.0 in (330 mm) 19 lbs (8.62 kg) Model (115 v): (230 v): Draw: Height: Width: Depth: Weight: 9,000 BTU 1 RE09A RE09B 15.0 in (381 mm) 14.0 in (343 mm) 10.0 in (254 mm) 66 lbs (30 kg) 24,000 BTU2 RE24A RE24B amps 12.0 in (305 mm) 32.0 in (813 mm) 14.0 in (356 mm) 51 lbs (23 kg) 12,000 BTU 1 RE12A RE12B 11.0 amps 15.0 in (381 mm) 14.0 in (343 mm) 10.0 in (254 mm) 64 lbs (29 kg) 32,000 BTU 2 RE32A RE32B amps 12.0 in (305 mm) 32.0 in (813 mm) 15.5 in (394 mm) 55 lbs (25 kg) Direct Expansion Remote Evaporator NOTES: Dimensions given for reverse cycle units. Consult factory for cool-only and 3 phase equipment. 1- insulated, multi-position blower with cap tube. 2- insulated, multi-position blower with cap tube and electric heat. For use with cool-only condensing units. Customized Options Available. Contact factory for details 13 DIRECT EXPANSION AIR CONDITIONING 12,000 BTU RC12 11.0 amps 5.9 amps 15.0 in (381 mm) 14.0 in (343 mm) 10.0 in (254 mm) 64 lbs (29 kg) 60,000 BTU RC60 -26.0 amps 17.0 in (432 mm) 21.0 in (533 mm) 13.0 in (330 mm) 152 lbs (69 kg) 48,000 BTU RC48 -22.7 amps 17.0 in (432 mm) 20.0 in (508 mm) 13.0 in (330 mm) 149 lbs (68 kg) Model Draw (115 v): (230 v): Height: Width: Depth: Weight:: 32,000 BTU RC32 -16.5 amps 17.0 in (432 mm) 17.0 in (432 mm) 13.0 in (330 mm) 128 lbs (58 kg) 24,000 BTU RC24 -12.0 amps 17.0 in (432 mm) 16.0 in (406 mm) 13.0 in (330 mm) 125 lbs (55 kg) Model Draw (115 v): (230 v): Height: Width: Depth: Weight:: 8,000 BTU RC08 9.0 amps 4.4 amps 15.0 in (381 mm) 14.0 in (343 mm) 10.0 in (254 mm) 59 lbs (26 kg) Model Draw (115 v): (230 v): Height: Width: Depth: Weight: NOTES: Dimensions given for reverse cycle units. Consult factory for cool-only and 3 phase equipment. 12 16,000 BTU RC16 15.0 amps 6.2 amps 15.0 in (381 mm) 14.0 in (343 mm) 10.0 in (254 mm) 66 lbs (30 kg) 40,000 BTU RC40 -22.5 amps 17.0 in (432 mm) 18.0 in (457 mm) 13.0 in (330 mm) 130 lbs (59 kg) Direct Expansion Condensing Unit Customized Options Available. Contact factory for details COOL TOUCH® DIGITAL CONTROL Technicold presents Cool Touch, the state of the art in touch screen temperature control and monitoring. Cool Touch offers a variety of function programs that allow you to tailor your air conditioning system to your vessel’s specific needs. • • • • Technicold’s Cool Touch panel maintains cooling or heating while automatically monitoring and selfdiagnosing the climate control system. The optional dehumidifying mode helps with environmental maintenance, ensuring a dry, odorless boat even while unattended. A touch button control panel provides a clear visual image of the current temperature, programs, fault messages and other optional screens - fully customizable and programmable from the factory prior to installation. Technicold’s Cool Touch is designed for ease of installation. No complicated wiring is required - the display panel, power control module and temperature sensor all connect with a polarized plug connection similar to a telephone or internet cable. Customized Options Available. Contact factory for details 11 DIGITAL CONTROLS User friendly four button display panel. Six programmable manual fan speeds. FX-1 FEATURES MODEL 19 programmable parameters for custom installations. Away mode to control relative humidity. FX-2 Same great features as FX-1, with smaller overall profile and bevel touch or joystick control. Vimar bezels available in colors that compliment your vessel’s decor. Available in CAN_bus configuration. FX-Maxx Same great features as FX-1 and FX-2 with full range of climate control options and push button simplicity. FX-Maxx Same great features as FX-Maxx. Equipped with convenient front panel cover. Hideaway FX-1 Digital Panel FX-2 Digital Panel FX-Maxx Hideaway Panel • Technicold digital controls include a power supply box, one 15” display and two 7’ sensor cables. • Technicold offers a comprehensive line up of optional cables and temperature sensors, to truly customize the way you interface with your climate control system. Customized Options Available. Contact factory for details 10 TECHNICOLD CHILLER CONTROL (TCC) The Technicold Chiller Control (TCC) offers over 28 standard monitoring and control functions for multi stage chilled water systems. Display is 6.5 “ full color touch screen for programing and monitoring up to 8 stages. STANDARD FEATURES • Compressor Duty Cycle • Fahrenheit / Celsius • Individual Chiller Flow Switch • Freeze Protection - Loop Water • Heating High Limit • Eight Maximum Stages • Network Compatible • Refrigerant High Pressure Switch • Refrigerant Low Pressure Switch • Hour Meter for Each Stage and Pumps • Automatic Set Point Adjustment • Multilingual Programming • Hurry Mode • Text Display • Remote Monitoring / Diagnostics • Evaporator Plate Freeze Protection • Directly Drives Compressor Contactors (if installed) • Directly Drives Heater Contactors (if installed) • Directly Drives Circ Water Pump Contactors • Directly Drives Raw Water Pump Contactors • Auxiliary voltage input for use when operating contactors of a different voltage than main supply voltage • VFD Start Relay (Dry Contact Output) • VFD Fault Signal Input • Universal Power Supply 115/230 VAC • Simple 2-Wire CANBus Control • Automatic Slave By-Pass and Retry for a Slave with fault • Cycled or Continuous Raw Water Pump operation • Raw Water Condenser Priming Feature prior to starting compressors OPTIONAL FUNCTIONS • Dual Function Input for High and Low Refrigerant Pressure Switch and Transducer • Refrigerant High and Low Pressure Transducer Inputs • Circulation Water High and Low Pressure Switch and Transducer Input • Circulation Water Pump Flow Switch Input • Raw water pump flow switch input • MODBUS Input for VFD Monitoring • Change over from TCC to back up manual control Customized Options Available. Contact factory for details 9 VARIABLE FREQUENCY DRIVES Variable Frequency Drives (VFD) for use with chilled water systems. Programming included. See the below sizing chart for the correct VFD for your application. Chiller Model CW36B CW36C CW36E CW36L CW48B CW48C CW48D CW48E CW48L CW60B CW60C CW60D CW60E CW60L CW72B CW72C CW72D CW72E CW90C CW90D CW90E CW120C CW120D CW120E CW180C CW180D 8 VFD Part Number 1 Phase In 3 Phase In (1) 7.5 HP 22-98924 5 HP 22-98923 7.5 HP 22-98924 5 HP 22-98923 - C/F (1) 7.5 HP 22-98924 5 HP 22-98923 - 5 HP 22-98923 - 5 HP 22-98923 - C/F (1) 10 HP 22-98918 7.5 HP 22-98924 - 7.5 HP 22-98927 - 7.5 HP 22-98927 - 7.5 HP 22-98927 (1) 10 HP 22-98918 7.5 HP 22-98924 - 7.5 HP 22-98927 - 7.5 HP 22-98927 - 10 HP 22-98918 - 10 HP 22-98920 - 10 HP 22-98920 - 10 HP 22-98918 - 10 HP 22-98920 - 10 HP 22-98920 - 20 HP 22-98926 - 15 HP 22-98928 Customized Options Available. Contact factory for details FRESH AIR MAKE-UP SYSTEMS Model (w/heat): Draw: Heat kW/Amps: Height: Width: Depth: Weight: 250 CFM 0 MA250VHB 0.93 1.25 / 5.21 12.2 in (311 mm) 18.8 in (479 mm) 17.4 in (422 mm) 39 lbs (17 kg) 500 CFM 4 MA500VHB 0.56 2.00 / 8.30 12.3 in (312 mm) 19.2 in (488 mm) 19.3 in (490 mm) 52 lbs (23 kg) 1000 CFM MA1000VHB 0.56 5.00 / 20.83 12.3 in (312 mm) 35.2 in (894 mm) 17.3 in (439 mm) 75 lbs (34 kg) MA1000VHB Customized Options Available. Contact factory for details 7 CHILLED WATER AIR HANDLERS High Velocity Air Handlers (includes water valve): 32,000 BTU4 RA32VB RA32VB-UV RA32VHB 12.8 in (324 mm) 35.0 in (889 mm) 12.7 in (323 mm) 56 lbs (12 kg) 24,000 BTU RA24VB RA24VB-UV RA24VHB 13.1 in (333 mm) 35.0 in (889 mm) 13.1 in (332 mm) 53 lbs (24 kg) Model (115V) Model (230V): CFM: Height: Width: Depth: Weight: 16,000 BTU 4 RA16VB RA16VB-UV RA16VHB 12.2 in (311 mm) 18.5 in (470 mm) 12.6 in (319 mm) 29 lbs (13 kg) 12,000 BTU0 RA12VB RA12VB-UV RA12VHB 12.8 in (325 mm) 18.5 in (470 mm) 12.9 in (329 mm) 28 lbs (13 kg) Model: Model (w/UV): Model (w/heat): Height: Width: Depth: Weight: 18,000 BTU4 RA18VB RA18VB-UV RA18VHB 12.3 in (314 mm) 19.9 in (505 mm) 13.4 in (340 mm) 34 lbs (15 kg) RA32VB 6 Customized Options Available. Contact factory for details CHILLED WATER AIR HANDLERS Horizontal Dual Air Handlers (includes water valve): 28,000 BTU4 TAH28B Consult Factory Consult Factory Consult Factory Consult Factory 22,000 BTU TAH22B 1202 in (305 mm) 43.1 in (1095 mm) 25.4 in (645mm) 122 lbs (55 kg) Model: Height: Width: Depth: Weight 12,000 BTU 4 TAH12B 11.2 in (286 mm) 36.0 in (914 mm) 21.0 in (533 mm) 90 lbs (41 kg) 6,000 BTU0 TAH06B 11.2 in (286 mm) 31.0 in (787 mm) 21.0 in (533 mm) 78 lbs (33 kg) Model: Height: Width: Depth: Weight: 16,000 BTU4 TAH16B 1.2 in (286 mm) 43.0 in (1052 mm) 20.8 in (528 mm) 109 lbs (49 kg) 33,000 BTU TAH33B Consult Factory Consult Factory Consult Factory Consult Factory • All air handlers are available with electric heat strips and UV anti-bacterial lights. Vertical Compact Air Handlers (includes water valve): Model: Model (w/heat): CFM: Height: Width: Depth: Weight: 12,000 BTU0 RAVC12B RAVC12BH 370 25.0 in (635 mm) 19.3 in (490 mm) 8.7 in (221 mm) 37 lbs (17 kgs) 16,000 BTU 4 RAVC16B RAVC16BH 450 26.0 in (660 mm) 19.3 in (490 mm) 8.6 in (218 mm) 38 lbs (17 kg) 18,000 BTU4 RAV18B RAV18BH 450 24.3 in (617 mm) 18.4 in (467 mm) 7.1 in (181 mm) 44 lbs (20 kg) Customized Options Available. Contact factory for details 5 Chilled Water Air Handler RA16 CHILLED WATER AIR HANDLERS Chilled Water Air Handler Double Blowers RA24 Standard Rotatable Blowers (includes water valve): 24,000 BTU4 RA24A RA2BA 700 12.0 in (305 mm) 35.0 in (889 mm) 13.5 in (394 mm) 51 lbs (23 kg) 18,000 BTU RA18A RA18B 500 12.0 in (305 mm) 19.0 in (483 mm) 17.6 in (447 mm) 33 lbs (15 kg) Model (115V) Model (230V): CFM: Height: Width: Depth: Weight: 12,000 BTU 4 RA12A RA12B 350 12.0 in (305 mm) 18.5 in (470 mm) 15.0 in (381 mm) 27 lbs (12 kg) 8,000 BTU0 RA08A RA08B 265 9.0 in (229 mm) 17.0 in (432 mm) 14.0 in (356 mm) 19 lbs (8 kg) Model (115V): Model (230V): CFM: Height: Width: Depth: Weight: 16,000 BTU4 RA16A RA16B 500 12.0 in (305 mm) 18.5 in (470 mm) 17.0 in (432 mm) 28 lbs (12 kg) 32,000 BTU RA32A RA32B 1,000 12.0 in (305 mm) 35.0 in (889 mm) 17.0 in (432 mm) 55 lbs (25 kg) • All air handlers are available with electric heat strips and UV anti-bacterial lights. 4 Customized Options Available. Contact factory for details CHILLED WATER SYSTEMS Model (1 ph1 - 230V): (1 ph1 - 220V): (3 ph2 - 280-230V): (3 ph2- 440V): (3 ph2 - 380V): Height: Width: Depth: Weight: 120,000 BTU --CW120C CW120D CW120E (50 Hz) 24.8 in (629 mm) 14.5 in (368 mm) 34.0 in (864 mm) 304 lbs (137 kg) 180,000 BTU --CW180C (208V) CW180D -53.0 in (1353 mm) 24.5 in (622 mm) 18.0 in (457 mm) Consult Factory FEATURES AND BENEFITS OF A TECHNICOLD CHILLER SYSTEM All Technicold chilled water Air Conditioning systems feature the following, and more: • Plate style chiller encapsulated in urethane foam inside a stainless steel housing enclosure prevents condensation. • Large diameter, single-pass fluted coaxial cupronickel counter-flow condenser allows low sea water velocity while providing maximum efficiency and even condensing. • Digital staging thermostat allows for continuous temperature readout and preset temperature control. • Freezestat control direct sensing on chiller plate surface protects plate from freezing up. • Circulating water flow switch protects against low water pressure and flow. • Expansion valve metering device provides maximum performance at all temperature ranges. • Easy access to sight glass for convenient service diagnostics. Customized Options Available. Contact factory for details 3 CHILLED WATER SYSTEMS 72,000 BTU CW72B3 -CW60C CW60D CW60E (50 Hz) 16.8 in (425 mm) 13.5 in (343 mm) 26.5 in (673 mm) 170 lbs (77 kg) 60,000 BTU 40 CW60B3 CW60L (50 Hz) CW60C CW60D CW60E (50 Hz) 16.8 in (425 mm) 13.5 in (343 mm) 26.5 in (673 mm) 170 lbs (77 kg) Model (1 ph1 - 230V): (1 ph1 - 220V): (3 ph2 - 280-230V): (3 ph2- 440V): (3 ph2 - 380V): Height: Width: Depth: Weight: 36,000 BTU CW36B3 CW36L CW36C CW36D CW36E (50 Hz) 16.0 in (406 mm) 13.5 in (343 mm) 26.5 in (673 mm) 164 lbs (74 kg) 24,000 BTU40 275 CW24B3 ----16.0 in (406 mm) 13.5 in (343 mm) 26.5 in (673 mm) 151 lbs (68 kg) Model (1 ph1 - 230V): (1 ph1 - 220V): (3 ph2 - 280-230V): (3 ph2- 440V): (3 ph2 - 380V): Height: Width: Depth: Weight: 48,000 BTU CW48B3 CW48L CW48C CW48D CW48E (50 Hz) 16.8 in (425 mm) 13.5 in (343 mm) 26.5 in (673 mm) 170 lbs (77 kg) 90,000 BTU --CW90C CW90D CW90E (50 Hz) 18.0 in (457 mm) 14.5 in (368 mm) 26.5 in (673 mm) 181 lbs (82 kg) NOTES: 1 - Single phase includes electric box with start and capacitor, relay and terminal strip. All single phase units are 60 Hz, except where indicated. 2- Three phase units are designed to be powered with a Variable Frequency Drive (see page xx for options). All three phase units are 60 Hz, except where indicated. 3- Available as ES Series; includes power supply with Easy Start, run capacitor and terminal strip. 2 Customized Options Available. Contact factory for details TABLE OF CONTENTS 4-6 Chilled Water Air Handlers 2-3 Chilled Water Air Conditioning Systems 9 Technicold Chiller Control (TCC) 8 Variable Frequency Drives 7 Fresh Air Make-Up Systems 17 Air Purification System 17 Load Banks 16 Refrigeration Condensing Units 15 Ducts & Pumps 14 Chiller Accessories 13 Direct Expansion Remote Evaporators 12 Direct Expansion Air Conditioning 11 Cool Touch® Digital Control 10 Digital Controls The specifications in this document are subject to change without notice. Please note that dimensions and weights of HVACR components can affected by optional equipment, AC output, phase (three phase or single phase may be options) and cooling configurations. Please contact the factory for special applications and derating factors. www.technicold.com Contact factory for installation drawings. Northern Lights® generators, Lugger® marine engines, and Technicold® marine systems are manufactured by Northern Lights, Inc., and are registered trademarks of Northern Lights Incorporated ©2015 4420 14th Avenue Northwest • Seattle, WA 98107-4616 Tel: (206) 789-3880 • (800) 762-0165 • Fax: (206) 782-5455 Web: www.northern-lights.com • E-mail: info@northern-lights.com Information, specifications, materials, and dimensions subject to change without notice. ©2015 All Rights Reserved. Litho in USA. L605