TYPE: -- SERIES S175 10 1/4" PERIMETER ADJUSTABLE MOUNTING YOKE (2-PER FIXTURE) 5" T-BAR CEILING OPENING 10” O.C. 9" 11" PLASTER CEILING OPENING 9 1/4” X FIXTURE LENGTH PLUS 1/4” 10.25" x 5.00" OPTIONS: 10 1/4" Mounting Options: ( Recessed ) FL - Flanged for plaster or dry wall ceilings (Mounting yokes supplied) T - Standard T-grid ceiling (T clips supplied) FL(TRM) - Trimless flange for plaster or dry wall ceilings. (Mounting Yokes Supplied) Lamp Options: BX - Biax T5 - 5/8" diameter lamp T5HO - 5/8" diameter lamp (High output) T8 - 1" diameter lamp Color Options: WHT - White (Standard) CA - Custom colors Electrical Options: UNV - Universal voltage 120/277 277V - 277 volt operation 347V - 347 volt operation 2CIR - 2 circuit wiring DIM - Dimming ballast (Consult factory) EM - Emergency ballast GLR - In line fusing 5" 9" 10 1/4" The S175 series is an easy to install, efficient, wall-washing fixture with the output of a much larger fixture. A low-irridescence specular reflector further enhances the high lumens of the Biax lamp. All S175 series fixtures have white enamel housings, bracketry and trim, with a lowirridescence. specular reflector system. Fixtures are UL/cUL listed, and have standard electronic ballasts. Each fixture is lamp-tested at the factory before shipment. ORDERING INFORMATION Series S175 Output - D Mounting - -- S175 D FL Perimeter Direct Flange 1 2 Lamp / Type Length Diffuser -- / -- - -- - -- BX BIAX T T5 T-Grid 5/8" Diamerter T5HO FL(TRM) Trimless Flange 2' 4' 5/8" Diamerter (High Output) T8 1" Diamerter www.pmclighting.com Specifications and Dimensions are subject to change without notice. 100 Gilbane Street / Warwick, RI 02886 • TEL 401.738.7266 • FAX 401.738.0618 Color - -- Voltage - -- Options - -- WHT UNV 2CIR White (Standard) Universal Voltage 2 Circuit Wireing CA 277V Dimming Ballast Custom Color 277 Volt Operation 347V 347 Volt Operation DIM EM Emergency Ballast GLR In Line Fusing S175 SERIES S175 MOUNTING Ceiling type must be specified when ordering fixtures. Modifications to the ceiling interface may be possible to accomodate some contemporary ceiling configurations. Details are required prior to manufacture. Please Note: All fixtures must be Supported by the Structural Ceiling PLASTER CEILING OPENING 9 1/4'' FL-Mounting for standard plaster-type ceilings PHOTOMETRY T-Mounting for standard T-Bar grid ceilings Model No. S175-D-1/BX-2-120 1 Lamps•2850 Lumens•Open Coefficients of Utilization RCR 1 2 3 4 5 6 7 8 9 10 70 80% 50 30 .76 .70 .64 .59 .54 .49 .45 .41 .38 .35 .73 .65 .58 .51 .45 .40 .36 .32 .29 .26 .71 .61 .50 .46 .39 .34 .31 .26 .23 .20 T-BAR CEILING OPENING 10” O.C. 70 70% 50 30 .74 .68 .63 .57 .52 .48 .44 .40 .37 .34 .72 .64 .57 .50 .44 .40 .35 .32 .28 .26 .70 .60 .52 .45 .39 .34 .30 .26 .23 .20 90° 50 50% 30 10 .69 .61 .55 .49 .43 .38 .34 .31 .27 .25 .67 .58 .51 .44 .38 .33 .29 .26 .22 .20 .65 .55 .47 .241 .34 .30 .26 .22 .19 .17 0° CANDELLA DISTRIBUTION SPECIFICATIONS CONSTRUCTION: Fixture Chassis die-formed of 20 Gauge (or Heavier) CRS. Internal Bracketry of 20 Gauge Steel. Reflectors are of low-irridescence specular aluminum. MOUNTING: Standard T-Bar Ceiling (T). Flanged fixtures for Plaster Ceilings (FL). Note: fixtures should be supported by structural ceiling. FINISH: Standard fixture trim is gloss white (WHT) Reflective internal steel components are finished in high gloss white enamel (Minimum Reflectance Factor 90%). ELECTRICAL: All fixtures are UL listed, and are shipped fully wired, individually tested, with Electronic S175 Ballasts shipped as standard equipment Line Fusing (GLR). 2 Circuit Wiring (2CIR). OPTIONS: FINISH: A range of custom trim colors are available to meet Architect specifications. Please consult the factory. All dimensions are subject to change, Consult the factory before making structural alterations. MOUNTING: For ceiling configurations other than standard, PMC may be able to modify the fixture/ceiling interface. Please consult the factory. ELECTRICAL: 277 Volt Ballast (277). Dimming Ballast (DIM). Emergency Ballast (EM) Note: unless specified, PMC will select ballasts to meet requirements. In Specifications and Dimensions are subject to change without notice. 100 Gilbane Street / Warwick, RI 02886 • TEL 401.738.7266 • FAX 401.738.0618 www.pmclighting.com