E2.9SA-HP-A15-TL

advertisement
EVOKE® 2.9” HP
E2.9SA-HP-A15-TL
LED
2.9” SQUARE ADJUSTABLE TRIMLESS LED
APPLICATION:
Commercial and retail accent lighting
HOUSING CONSTRUCTION:
20 ga. steel painted matte black
Formed aperture plate with 5/8” lip (GB-standard)
Cast aluminum plaster frame with perforated face
Integral adjustable locking mounting bars
Thermally protected
REFLECTOR TRIM CONSTRUCTION:
Die-cast aluminum seamless self-flange reflector trim
Painted finishes include matte white and optical matte black
with matte white flange
Spring steel mounting clips
ELECTRICAL:
Electronic constant current LED driver, 120v or 277v input
(voltage specific TP on 18w & 20w)
ELV and Triac dimming standard, 120v or 277v.
0-10v, Lutron & DALI systems available. See following pages
for more information.
This product complies with IEEE C62.41 for surge endurance
up to 2.5KV. Amerlux® recommends using additional surge
protection with this unit (supplied by others), surge damage
is not covered by warranty.
OPTICS:
Cam adjustment mechanism provides lockable 0-40º tilt;
360º+ rotation
Available in a variety of beam spreads
LED:
Color Temp Options: 2200K, 2700K, 3000K, 3500K, 4000K
CRI: 83 typ. (2700K, 3000K, 3500K, 4000K)
97 typ. (2200K, 2700K, 3000K)
Amerlux Crisp White technology available (18w max)
R9 Value: 11 (83CRI), 92 (97CRI)
Binning: 3 MacAdam (SDCM)
Life: 50,000 hrs
Lumen Maintenance: >70% of initial lumens @ 50,000 hrs
Lumen Output (20w, 20º tilt, 3000K): up to 1154 lm, 59 lm/w
CBCP (20w, 20º tilt, 3000K): up to 10839
MOUNTING:
For use in sheet rock ceilings, ceiling thickness 5/8”
Other Ceilings: Consult factory for other ceiling thicknesses or
for use in millwork ceilings
PROJECT:
LABELING:
TYPE:
Damp location
IC/AT rated (11w only)
11 7/8”
5 1/8”
11 5/16”
/16”
5 5/ 8”
7
5 3/8”
7 13/16”
9 11/16”
3 /16”
Electrostatic sensitive device,
observe precautions for
handling
15
12 3/4”
40º
5
14 1/2” min - 25” max
2.9”
3 1/4”
/8”
Ceiling Cut Out Dimension: 4 1/16”
ELECTRICAL
Electronic driver
11w
18w*
20w*
System
System
System
Watts Amps Watts Amps
Watts Amps
120v
11
0.09
18
0.15
20
0.17
277v
11
0.04
18
0.06
20
0.07
* 2w thermal protector included on 18w & 20w
1. Reflector Trim
2. Fixture Housing Aperture Plate
3. Ceiling 5/8” (1” max)
4. Cast Aluminum Plaster Frame
5. Plaster Skim Coat (by others)
6. 6-32 Type F Thread Cutting Screw
3
1
2
6
5
5
4
(see website for details)
ORDERING INFORMATION:
Housing
Model
Wattage Lamp Voltage Beam Spread
Type
E2.9SA-HP-A15-TL 11
18
20
LED
120
277
SP - spot, 15º
NF - narrow
flood, 20º
MFL - medium
flood, 24º
FL - flood, 28º
WF - wide flood,
45º
VWF - very wide
flood, 60º
LS - linear spread,
60º x 10º
Color
Temp
Options
83 CRI
2700
3000
3500
4000
HILUME - Lutron Hi-lume®
A-series dimming
(Ecosystem or 3 wire)
0-10V - 0-10v dimming
DALI - DALI driver
CP - Chicago Plenum (CCEA)
97 CRI
IC/AT - insulated ceiling/air
2200-97
tight (11w only)
2700-97
MWHSG - millwork housing,
3000-97
specify ceiling
thickness (used with
CRISP - Crisp
MWFLG reflector
White
option)
(18w max)
Complete Unit Specification: E2.9SA-HP-A15-TL-20-LED-120-SP-3000/E2.9SA-HP-A15-TL-MW
Housing Only: E2.9SA-HP-A15-TL-20-LED-120-SP-3000
Reflector Only: E2.9SA-HP-A15-TL-MW
Cat #:
Amerlux® reserves the right to change details that do not affect overall function and performance.
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973.882.5010 F: 973-882.2605 • www.amerlux.com
Reflector
Model
Aperture
Finish
E2.9SA-HP-A15-TL MB - matte
black
MW - matte
white
SLV - matte
silver
Options
MWFLG - millwork flange
trimless (used
with MWHSG
housing option)
EVOKE® 2.9” HP
E2.9SA-HP-A15-TL
LED
2.9” SQUARE ADJUSTABLE TRIMLESS LED
TYPE:
FIXTURE DATA: For 11w data, multiply by 0.55; For 18w data, multiply by 0.9
Complete photometric data (ies format) available upon request.
20W LED
SPOT
DISTRIBUTION
LTL # 1178270
NARROW FLOOD
DISTRIBUTION
LTL # 1178271
FLOOD
DISTRIBUTION
LTL # 1178273
75
500
750
1500
60
60
60
60
5000
75
75
75
2500
90
90
90
90
1500
3000
45
7500
WIDE FLOOD
DISTRIBUTION
LTL # 1178274
45
2250
45
4500
1000
10000
3000
2000
6000
0
15
0
30
Candelas at Nadir
Deg
Candela
0
412
5
1283
15
6819
20
10760
25
8143
35
1819
45
163
APPLICATION DATA:
15
0
30
Candelas at Nadir
Deg
Candela
0
675
5
1602
15
5104
20
6138
25
5402
35
1823
45
242
15
30
0
Candelas at Nadir
Deg
Candela
0
976
5
1593
15
2922
20
3182
25
3004
35
1769
45
440
Notes and Definitions:
Beam spread is to 50% center beam candlepower (CBCP).
D=Distance to floor or wall.
FC=Footcandles on floor or wall at center beam aiming location.
L=Effective Visual Beam length in feet (50% of maximum footcandle level).
W=Effective Visual Beam width in feet (50% of maximum footcandle level).
CB=Distance across or down to center beam location.
20o Aiming Angle
Horizontal
Footcandles
15
30
Candelas at Nadir
Deg
Candela
0
959
5
1324
15
1960
20
2104
25
2073
35
1519
45
512
D
CB
30°
30°
D
FC
L
W
W
FC
L
CB
W
FC
L
20o Aiming Angle
Vertical
Footcandles
SPOT
D
5.0’
7.5’
10.0’
12.5’
FC
340
151
85
55
L
1.7
2.4
3.2
4.0
W
1.4
2.0
2.8
3.5
CB
2.0
3.0
4.0
5.0
D
3.0’
4.0’
5.0’
6.0’
FC
56
34
22
16
L
5.1
6.6
8.3
10.2
W
2.5
3.1
3.7
4.3
CB
6.5
8.5
10.5
12.5
NARROW
FLOOD
D
5.0’
7.5’
10.0’
12.5’
FC
195
87
50
33
L
2.2
3.2
4.3
5.1
W
1.9
2.8
3.8
4.8
CB
2.0
3.0
3.0
4.0
D
3.0’
4.0’
5.0’
6.0’
FC
41
25
17
12
L
5.1
6.7
8.3
10.5
W
2.8
3.5
4.2
5.0
CB
5.5
7.5
9.5
11.5
FLOOD
20º30°
D
5.0’
7.5’
10.0’
12.5’
FC
102
47
27
17
L
3.0
4.4
5.7
7.2
W
2.8
4.0
5.3
6.7
CB
2.0
2.0
3.0
4.0
D
3.0’
4.0’
5.0’
6.0’
FC
32
19
13
9
L
4.7
6.1
7.6
9.2
W
3.2
4.1
5.0
6.0
CB
4.5
6.5
7.5
8.5
WIDE
FLOOD
20o °
45
1500
D
5.0’
7.5’
10.0’
12.5’
FC
68
32
18
12
L
3.7
5.3
7.0
8.8
W
3.3
5.0
6.7
8.3
CB
2.0
2.0
3.0
4.0
D
3.0’
4.0’
5.0’
6.0’
FC
28
17
11
8
L
4.2
5.3
6.5
8.0
W
3.4
4.4
5.3
6.4
CB
4.5
5.5
6.5
8.5
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973.882.5010 F: 973-882.2605 • www.amerlux.com
LIT-1773 rev 12/15
EVOKE® 2.9” HP
E2.9SA-HP-A15-TL
LED
2.9” SQUARE ADJUSTABLE TRIMLESS LED
TYPE:
DIMMING COMPATIBILITY:
Amerlux® fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux® recommends testing your unique dimming configuration as the exact full
configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance.
TRIAC (Forward Phase) DIMMING (standard)
Utilizes “Standard” incandescent dimmers that are in wide use in installations across the US. Best for retrofit applications
where Triac dimmers are installed.
Wiring Diagram
Notes:
• 120v or 277v
Driver
Triac
• Dims down to less than 5% light output (most cases)
Black Black
Dimmer
LED
• Consult Dimming manufacturer for installation
RED
White
(by
others)
instructions - DO NOT SHARE NEUTRALS!
Green
• Must meet dimmer Minimum Load Requirements
per dimming manufacturer
120v
Compatible Dimmers
Wall Box (Incandescent Style, Wattage as required)
Central System
Lutron “Diva”
Lutron “Vareo”
ETC “SR” Rack w/D20
ETC “DRD” Rack w/D20
Lutron “Nova-T”
Lutron “Skylark”
Module
Module
Lutron “Maestro”
Lutron “GP” Panel
Lutron Grafix Eye QS
ELV - Electronic Low Voltage (Reverse Phase) DIMMING (standard)
Utilizes specialized “ELV” dimmers. Best for New Construction applications
Notes:
• 120v or 277v
• Dims down to less than 5% light output (most cases)
• Consult Dimming manufacturer for installation
instructions - DO NOT SHARE NEUTRALS!
• Must meet dimmer Minimum Load Requirements
Wiring Diagram
ELV
Dimmer
(by others)
Driver
Black Black
RED
White
Green
LED
120v
Compatible Dimmers
Wall Box (ELV Style)
Lutron “Diva”
Lutron “Nova-T”
Lutron “Maestro”
Leviton “Surslide”
Lutron “Vareo”
Lutron “Skylark”
Leviton “Vizio”
Central System
ETC “SR” Rack w/ELV10
Module
Lutron “GP” Panel with
PHPM-PA Interface
ETC “DRD” Rack w/ELV10
Module
Lutron Grafix Eye QS with
PHPM-PA Interface
0-10V - DIMMING (-0-10V Option)
Integrates into a variety of building management and daylighting controls
Wiring Diagram
Notes:
• 120v - 277v
• Dims down to less than 10% light output
• Requires interface to turn off power to driver
• Consult Dimming manufacturer for installation
instructions - DO NOT SHARE NEUTRALS!
Compatible Dimmers
Wall Box
Lutron “Diva” - DVTV with
PP-120H Interface
Leviton Renoir II 0-10v
0-10v
Dimmer
Bldg
Power or
Interface
Driver
Violet Black
RED
Grey
LED
Black
White
Green
Central System
Lutron Grafix Eye with
GRX-TVI Interface
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973.882.5010 F: 973-882.2605 • www.amerlux.com
LIT-1773 rev 12/15
EVOKE® 2.9” HP
E2.9SA-HP-A15-TL
LED
2.9” SQUARE ADJUSTABLE TRIMLESS LED
TYPE:
LUTRON HI-LUME / ECO-SYSTEM (-HILUME Option)
Integrates into a variety of building management and daylighting controls
3-Wire Wiring Diagram
Notes:
• 120v or 277v
Driver
• Dims down to less than 5% light output
3-Wire FL
Black
Switched Hot
• May use 3-Wire or Ecosystem Control
Control
Orange
Dimmed Hot
• Consult Dimming manufacturer for installation
(by others)
White
Neu
instructions - DO NOT SHARE NEUTRALS!
Green
Gnd
Purple/Grey E2
Purple
E1
Compatible Dimmers
Wall Box (3-Wire Fluorescent)
ECO-Sys Bus
DIVA
Cap Wires
Maestro
Nova T
ECO System Digital Control Wiring
Vareo
Cap Lead
Central System
Lutron ECO-System compatible controls
ETC “SR” Rack w/D20F Module
ETC “DRD” Rack w/D20F Module
ECO
System
Control
Black
Orange
White
Green
Purple/Grey
Purple
(by others)
VV+
Driver
Switched Hot
Dimmed Hot
VV+
Black
RED
LED
Black
RED
LED
Neu
Gnd
E2
E1
ECO-Sys Bus
Amerlux®, LLC • 178 Bauer Drive, Oakland, NJ 07436 • P: 973.882.5010 F: 973-882.2605 • www.amerlux.com