SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL TECHNICAL SYSTEMS (NTS) Plano Division 1701 E Plano Pkwy Suite 150 Plano, Texas 75074 Kimberly Zavala Phone: 972 509 2566 Kimberly.Zavala@ntscorp.com ELECTRICAL (EMC) Valid to: December 31, 2017 Certificate Number: 0214.19 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s EPA ENERGY STAR Accreditation Program Requirements1), accreditation is granted to this laboratory to perform the following tests: Test Technology: Emissions Radiated Emissions (3 m Semi Anechoic Chamber, 10 m Semi Anechoic Chamber) Test Capabilities: Test Method(s)2: 60 Hz to 40 GHz Code of Federal Regulation (CFR) 47, FCC Part 15 (Subpart B) using ANSI C63.4: 2003, ANSI C63.4:2009 and ANSI C63.4:2014; FCC Part 18 (using MP5) CISPR 22; EN 55022; KN 22; AS/NZS CISPR 22:2009+A1 :2010; CISPR 32; EN 55032; CISPR 11; EN 55011; AS/NZS CISPR 11:2011; KN 11; VCCI V-3 (up to 6 GHz); CNS 13438 (up to 6 GHz); TCVN 7189 (2009); CISPR 25; CISPR 12; ICES-003; EN 13309; ISO 13766; ISO 11451-2; KN 32 MIL-PRF-28800F; MIL-STD-461 B-F (Methods RE101, RE102, RE103); MIL-STD-462; RTCA/DO-160 C-G (Sections 15, 21) Conducted Emissions 30 Hz to 100 MHz Code of Federal Regulation (CFR) 47, FCC Part 15 (Subpart B) using ANSI C63.4:2003, ANSI C63.4:2009 and ANSI C63.4:2014; FCC Part 18 (using MP5) CISPR 22; EN 55022; AS/NZS CISPR 22; KN 22; CISPR 32; EN 55032; CISPR 11; EN 55011; AS/NZS CISPR 11; KN 11; VCCI V-3; CNS 13438; TCVN 7189 (2009); CISPR 25; ICES-003; ISO 13766 MIL-STD-461 B-F (Methods CE101, CE102); MIL-STD-462; MIL-PRF-28800F; RTCA/DO-160 C-G (Section 21) (A2LA Cert. No. 0214.19) 01/15/2016 Page 1 of 6 Test Technology: Test Capabilities: Emissions (cont’d) Current Harmonics IEC/EN 61000-3-2; AS/NZS 61000.3.2 IEC/EN 61000-3-3; AS/NZS 61000.3.3 Flicker Immunity Electrostatic Discharge (ESD) Radiated Immunity Test Method(s)2: 15 kV air, 8 kV contact EN/IEC/KN 61000-4-2; MIL-PRF-28800F; RTCA/DO-160 C-G (Section 25); ISO 10605; ISO 13766 10 kHz to 40 GHz EN/IEC/KN 61000-4-3; MIL-STD-461 B-F (Methods RS101, RS103); MIL-STD-462; MIL-PRF-28800F; DoD-STD-1399, Section 300A and B; IEEE P1613; MIL-STD 1275; IEC/EN 55104; ISO 13766; EN 13309; ISO 11451-2; GR-1089-CORE; ISO 11452-2; RTCA/DO-160 C-G (Section 20) Electrical Fast Transient/Burst EN/IEC/KN 61000-4-4; MIL-PRF-28800F; IEEE P1613 Surge EN/IEC/KN 61000-4-5; IEEE P1613; IEEE 37.90.1; K20; K21; RTCA/DO-160 C-G (Section 22) Conducted Immunity 10 kHz to 400MHz EN/IEC/KN 61000-4-6; MIL-STD-1399; MIL-STD-461 B-F (Methods CS101, CS102, CS103, CS104, CS105, CS109, CS114, CS115, CS116); MIL-STD-462; MIL-PRF-28800F; RTCA/DO-160C-G (Section 16, 17, 18,19, 20, 22) Power Frequency Magnetic Field Immunity EN/IEC/KN 61000-4-8 Voltage Dips, Short Interruptions and Line Voltage Variations EN/IEC/KN 61000-4-11 DC Power Transients MIL-STD-704 A-F; EN 300 132; ANSI T1.315; ATT-TP-76200; ATT-TP-76450 Lightning/AC Power Cross GR-1089-CORE; MIL-STD-704 A-F Steady State Power Induction GR-1089-CORE; ETSI EN 300 386; AT&T-TP76200 DC Potential GR-1089-CORE; AT&T-TP76200 Electrical Safety GR 1089-CORE; AT&T-TP76200 Bonding & Grounding GR 1089-CORE; AT&T-TP76200 (A2LA Cert. No. 0214.19) 01/15/2016 Page 2 of 6 Test Technology: Test Capabilities: Immunity (Cont’d) Insulation Resistance Test Method(s)2: GR-49-CORE; GR-937-CORE; GR-950-CORE; GR-2916-CORE Energy Efficiency for Telecom. Equipment ATIS-0600015; VZ.TPR.9205; IEEE P1613 Heat Dissipation GR-63-CORE; ATIS-0600010 DC Power Port GR-1089-CORE (Section 10) Wireless EU ETSI 300 200-2; ETSI EN 300 328; ETSI EN 300 330-2; ETSI EN 300 440-2; ETSI EN 301 893 Industry Canada Radio Standards Specifications (RSS) RSS-GEN; RSS-119; RSS-123; RSS-125; RSS-127; RSS-130; RSS-131; RSS-132; RSS-133; RSS-139; RSS-210; RSS-310 Intentional and Unintentional Radiators to FCC Regulations (Up to 40GHz) Excluding HAC (Supports TCB Scopes A1-A4 and B1-B4) 47 CFR (FCC Rules) Part 15.A; 47 CFR (FCC Rules) Part 15.B, using ANSI C63.10:2009 and C63.10:2013; 47 CFR (FCC Rules) Part 15.C, using ANSI C63.10:2009 and C63.10:2013; 47 CFR (FCC Rules) Part 15.E, using ANSI C63.10:2009 and C63.10:2013; 47 CFR (FCC Rules) Parts 22 (Cellular and Non-Cellular), 24, 27, 74, 80, 87, 90, 95, and 101, using ANSI/TIA 603-C-2004 Energy Management American National Standard for Electric Meters Code for Electricity Metering / Electricicy Meters – 0.2 and 0.5 Accuracy Classes ENERGY STAR Testing1 Office Equipment Computers ANSI C12.1/C12.20 (excluding tests 20, 21, 36, 37, and 38) ENERGY STAR Test Method for Computers (Oct-2014); ENERGY STAR Program Requirements Product Specification for Computers (Ver. 6.1, Oct-2014) Enterprise Servers ENERGY STAR Program Requirements Product Specification for Computer servers (Ver. 2.0, Oct-2013); Standard Performance Evaluation Corporation (SPEC) most current Server Efficiency Rating Tool (SERT) Imaging Equipment ENERGY STAR Imaging Equipment Test Method (Rev. Oct-2014); ENERGY STAR Program Requirements, Product Specification for Imaging Equipment (Ver. 2.0 Oct-2014) (A2LA Cert. No. 0214.19) 01/15/2016 Page 3 of 6 Test Technology: Test Capabilities: Test Method(s)2: Generic/Product Family Standards and Industry Standards IEC/EN 61000-6-1; IEC/EN/KN 61000-6-2; IEC/EN 61000-6-3; IEC/EN/KN 61000-6-4; CISPR 24; EN 55024; KN 24; EN 61326; ETSI EN 300 386; GR-1089-CORE; ATT-TP-76200; IEC/EN 60601-1-2; EN 50082; AS/NZS 61000.6.3; AS/NZS 61000.6.4; EN 61326; IEC 60601-1-2; CISPR 14-1; KN 14-1; CISPR 14-2; KN 14-2; EN 55014-2; KN 35 Hearing Aid Compatibility CS03 Part V, Issue 9, Amendment 1, 2009; FCC Part 68.316; FCC Part 68.317 Telecom Analog 2 Wire T1 1.54 Mbps AS/CA S002:2015 Analogue Interworking and Noninterference Requirements for Customer Equipment for Connection to the Public Switched Telephone Network; AS/CA S003:2015 Telecommunications Technical Standard (Requirements for Customer Access Equipment for connection to a Telecommunications Network CS03- Part 1 (Analog TE), Issue 9, Amendment 4, 2010; ETSI EN 301 437 Voice Analog TE; ETSI ES 203 021 Analog TE; TIA 968-B Analog 2 Wire TE; HKCA 2011 (Analog TE); PSTN 01(Analog TE, Taiwan); TBR 21 (Analog TE, historical); IDA TS PSTN:2011; ETSI EN 301 437 Voice Analog TE; Ministry of Communications Specification 023/96; PTC 200, Requirements for Connection of Customer Equipment to Analogue Lines; JATE (Analog Telephone Terminals) CS03 Part 11 (1.5M), Issue 9, Amendment 1, 2012; TIA 968-B 1.54 Mbps TE; HKCA 2017 (1.5M DTMF); ID0002: DS1 Terminal Equipment Technical Specifications; ITU-T G 703: 2011 (Digital Interface); JATE (1.5M) ISDN 1.54 Mbps-PRI CS03 Part VI (1.5 M ISDN PRI), Issue 9, Amendment 1, 2012; TBR 4 (ISDN PRI); PTC 220, Requirements for Private Voice Networks connected to the PSTN/ISDN E1 2.0M AS/ACIF S016:2015 (E1 CE); TBR 12 (E1); TBR 13 (E1); ITU-T G 703: 2001 (Digital Interface); JATE (2.0M); ITU-T G 823: 2000 (E1 Jitter and Wander) (A2LA Cert. No. 0214.19) 01/15/2016 Page 4 of 6 Test Technology: Test Capabilities: Telecom (Cont’d) xDSL Product Safety Test Method(s)2: AS/ACIF S041:2015, Requirements for Customer Equipment for connection to a metallic local loop interface of a Telecommunications Network Part 2: Broadband; AS/ACIF S043:2015, Requirements for Customer Equipment for connection to a metallic local loop interface of a Telecommunications Network; CS03 Part VIII xDSL(A3 2007), Issue 9, Amendment 4, 2009; ETSI TS 101 270 VDSL; ETSI TS 101 388 V1.3.1 (2002 ADSL); TIA 968-B xDSL; ITU-T G 991.2 (2003, SHDSL); ITU-T G 991.2 (A3, 2005, SHDSL); ITU-T G 992.1 (1999, ADSL); ITU-T G 992.3 (2005, ADSL2); ITU-T G 992.3 (A5, 2008, ADSL2); ITU-T G 992.3 (2005, ADSL2+); ITU-T G 992.5 (2005, VDSL); ITU-T G 992.5 (A5, 2008, ADSL2+); ITU-T G 993.1 (2004, VDSL); ITU-T G 993.2 (2006, VDSL2) Insulation Resistance Leakage Current Temperature Rise Dielectric Strength Short Circuit Tests Grounding Impedance Overvoltage Tests Handle Strength Cord Anchorage Force Test Clearance and Creepage Distance Measurement Temperature/Humidity (Environmental Conditioning) Enclosure/Material Integrity Current/Voltage/Watts Measurement Impact (Steel Ball and Impact Hammer) Stability Mold Stress Relief Accessibility Drop Tests Overload Tests Wallmount Test Strain Relief Abnormal Operations (Induced Faults) Marking Durability Impulse/Lightning Testing (A2LA Cert. No. 0214.19) 01/15/2016 CSA C22.2 No. 61010-1; EN 61010-1; IEC 61010-1; UL 61010-1; IEC 61010-2-101; CSA C22.2 No. 61010-2-81; IEC 61010-2-81; EN 61010-2-81; CSA C22.2 No. 61010-1-12; EN 60825-1 (excluding section 9); CSA C22.2 No. 60950-1; IEC 60950-1; EN 60950-1; UL 60950-1; AS/NZS 60950-1:2011; IEC 60065; CSA C22.2 No. 61010-1; EN 61010-1; IEC 61010-1; UL 61010-1; IEC 61010-2-101; CSA C22.2 No. 61010-2-81; IEC 61010-2-81; EN 61010-2-81; CSA C22.2 No. 61010-1-12; EN 60825-1 (excluding section 9); CSA C22.2 No. 60950-1; IEC 60950-1; EN 60950-1; UL 60950-1; AS/NZS 60950-1; IEC 60065 Page 5 of 6 1 A2LA provides accreditation to the U.S. EPA’s Conditions and Criteria for Recognition of Laboratories for the ENERGY STAR Program by verifying an organization’s compliance to A2LA document R222 - Specific Requirements - EPA ENERGY STAR Accreditation Program and to the related test methods listed above Accreditation by A2LA does not infer Recognition by the EPA for ENERGY STAR testing. Please verify this organization’s recognition status at the EPA’s website, located at http://www.energystar.gov/index.cfm?fuseaction=recognized_bodies_list.show_RCB_search_form 2 When the date, revision or edition of a test method standard is not identified on the scope of accreditation, the laboratory is required to be using the current version within one year of the date of publication, per part C., Section 1 of A2LA R101 - General Requirements-Accreditation of ISO-IEC 17025 Laboratories. (A2LA Cert. No. 0214.19) 01/15/2016 Page 6 of 6 Accredited Laboratory A2LA has accredited NATIONAL TECHNICAL SYSTEMS (NTS) Plano, TX for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of any additional program requirements in the Electrical field. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 15th day of January 2016. _______________________ Senior Director of Quality & Communications For the Accreditation Council Certificate Number 0214.19 Valid to December 31, 2017 For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.