RISER DIAGRAM - Security Door Controls

advertisement
RISER DIAGRAM
TO FIRE ALARM – CLOSED
CONTACT CONNECTION
TO 120VAC POWER SOURCE
631RFx
UR1
4 COND
4 COND
4 COND
4 COND
CB401B
PUSH BUTTON
CB401B
PUSH BUTTON
4 COND
®
®
1511 EMLOCK
1511 EMLOCK
CB401A
PUSH BUTTON
(INSIDE)
NOTES: (1) ALL LOW VOLTAGE SIGNAL WIRING SHALL BE 20-GAUGE MINIMUM. THE MINIMUM INDUCTIVE LOAD (LOCK) POWER WIRE GAUGE SHALL BE DETERMINED PER THE SDC WIRE
GAUGE CHART. ALL WIRING (SINGLE OR MULTI-CONDUCTOR) SHALL BE COLOR CODED WITHOUT SPLICES. A MINIMUM OF TWO SPARE CONDUCTORS IS RECOMMENDED. (2) SPECIFY
VOLTAGE WHEN ORDERING PRODUCTS. VOLTAGE IS NOT SPECIFIED ON THIS WIRE DIAGRAM, BE SURE ALL PRODUCTS ARE VOLTAGE COMPATIBLE. (3) ALL WIRING MUST CONFORM
TO NATIONAL, STATE AND LOCAL CODES. (4) ALWAYS CONSULT WITH THE AUTHORITY HAVING JURISDICTION (AHJ) BEFORE INSTALLATION. (5) WHERE REQUIRED BY CODE, CONNECT
FAILSAFE SYSTEMS TO THE LOCAL FIRE LIFE SAFETY SYSTEM FOR EMERGENCY RELEASE.
Components
Qty
2
1
2
1
Description
1650lb. Magnetic Lock w/ Door Position Switch
1.5 Amp Power Supply x Universal Relay Module
Emergency Access Push Button Switch
System Activation Push Button Switch
Part Number
1511VD
631RF x UR1
CB401B
CB401AU
Manufacturer
SDC
SDC
SDC
SDC
Method of Operation
Both doors shall be normally unlocked. System Activation: All doors must be closed to lock. Pressing the CB401A Push Button will lock all
the doors. Egress: When the doors are locked, pressing the CB401A Push Button again unlocks all the doors. Emergency Release: When
the doors are locked, activating either of the CB401B Emergency Push Buttons will unlock both doors. Both doors will unlock automatically
via signal from the fire panel.
© Security Door Controls
PROJECT NAME:
LOCATION.:
TITLE:
Solution #2 - Communicating Bath
801 Avenida Acaso
Camarillo, CA 93012
t 805.494.0622 ~ f 805.494.8861
www.sdcsecurity.com
NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE
PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR IT’S
CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN THE WHICH
THE EQUIPMENT INSTALLED AND OPERATED. ALL WIRING MUST
CONFORM TO NATIONAL, STATE, AND LOCAL CODES FOR CLASS 2 FIRE
PROTECTION AND CONTROL DEVICES.
Comm Bath 1511 EMLock w/DPS - 631RFxUR1
SO NO.:
DIST.:
CONTACT:
DATE:
DRAWN
BY:
REV
A
DWG. NO.:
Page 1 of 2
1511VD EMLOCK®
Switch No:
Position
CB401-B
PUSH BUTTON SWITCH
LAMP
RED
EMERGENCY
RELEASE
UR1
NC
ORG
DPS
RED
PUSH
TO UNLOCK DOOR
YEL
WHT
NO
{
C
Set to
CR Mode
SW1 SW2 SW3 SW4
off
off
off
off
A
w
D
B
631RFxUR1 – 1.5 AMP POWER SUPPLY
WITH UNIVERSAL RELAY MODULE
w
D
NO
- +
PWR
C NO C NO - NO C NC - NO C NC
COM
TRIG A
TRIG B
RELAY A
RELAY B
TO 120VAC PRIMARY
VOLTAGE CONNECTION
NC
+
POWER
-
DOOR 1
J1
DOOR 1
G W B
+
RED
EMERGENCY
RELEASE
ORG
PUSH
TO UNLOCK DOOR
+
-
C
J1
NC
DPS
RED
-
STANDBY
BATTERY
CONNECTION
CB401-B
PUSH BUTTON SWITCH
LAMP
+
-
1511VD EMLOCK®
REMOVE JUMPER J1 FOR
24VDC OPERATION.
REFER TO POWER
SUPPLY INSTRUCTIONS
FOR VOLTAGE
SELECTION PROCEDURE
YEL
NO
WHT
C
{
(REMOVE FACTORY JUMPER ONLY
IF FIRE ALARM IS USED)
NO
COM
24VDC
OUTPUT
NC
+
POWER
-
DOOR 2
J1
DOOR 2
CLOSED FIRE
ALARM CONTACT
NOTE: EMLOCK® DPS SHOWN WITH
DOOR IN THE CLOSED POSITION.
NOTES:
(1) ALL LOW VOLTAGE SIGNAL WIRING SHALL BE 18-GAUGE MINIMUM. THE MINIMUM
INDUCTIVE LOAD (LOCK) POWER WIRE GAUGE SHALL BE DETERMINED PER THE SDC
WIRE GAUGE CHART. ALL WIRING (SINGLE OR MULTI-CONDUCTOR) SHALL BE COLOR
CODED WITHOUT SPLICES. A MINIMUM OF TWO SPARE CONDUCTORS IS
RECOMMENDED.
CB401-AU
PUSH BUTTON SWITCH
LAMP
RED
(2) SPECIFY VOLTAGE WHEN ORDERING PRODUCTS. VOLTAGE IS NOT SPECIFIED ON
THIS WIRE DIAGRAM, BE SURE ALL PRODUCTS ARE VOLTAGE COMPATIBLE.
RED
NC
ORG
(3) ALL WIRING MUST CONFORM TO NATIONAL, STATE AND LOCAL CODES.
BOTHDOORS MUST BE
CLOSED TO LOCK
YEL
WHT
(4) ALWAYS CONSULT WITH THE AUTHORITY HAVING JURISDICTION (AHJ) BEFORE
INSTALLATION.
BATHROOM LOCK
C
NO
PUSH TO
LOCK OR UNLOCK
LIGHT ONDOOR LOCKED
(5) WHERE REQUIRED BY CODE, CONNECT FAILSAFE SYSTEMS TO THE LOCAL FIRE
LIFE SAFETY SYSTEM FOR EMERGENCY RELEASE.
ACTIVATION SWITCH
(6) DOOR POSITION SWITCHES SHOWN WITH THE DOOR CLOSED
© Security Door Controls
801 Avenida Acaso
Camarillo, CA 93012
t 805.494.0622 ~ f 805.494.8861
www.sdcsecurity.com
NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE
PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR IT’S
CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN THE
WHICH THE EQUIPMENT INSTALLED AND OPERATED. ALL WIRING
MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES FOR
CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.
PROJECT NAME:
TITLE:
Solution #2 - Communicating Bath
LOCATION.:
DIST.:
SO NO.:
Comm Bath 1511 EMLock w/DPS - 631RFxUR1
CONTACT:
DATE:
DRAWN BY:
REV
A
DWG. NO.:
Page 2 of 2