Liebert Products & Service World Headquarters United States 1050 Dearborn Drive, P.O. Box 29186 Columbus, Ohio 43229 Telephone: 614-888-0246 Facsimile: 614-841-6973 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco Italy Telephone: 39-049-9719-111 Facsimile: 39-049-5841-257 Asia 29/F, The Orient Square Building F. Ortigas Jr. Road, Ortigas Center Pasig City 1605 Philippines Telephone: 63 2 687 6615 Facsimile: 63 2 730 9572 Liebert Mini-Mate2 Job Name Model Quantity Date Invoice # Purchaser P.O. # Tag # Submitted By PG1 MRI AND IMAGING OF WEST PACES MMD24E7XHSDF 1 Mar 9, 2015 CN2241148 Strictly Mechanical Lauren Inman Rev 10/10 Liebert Mini-Mate2 Ceiling-Mounted Precision Cooling Units ENGINEERING SPECIFICATION SHEET Project Name: MRI AND IMAGING OF WEST PACES Date: 12/16/2014 Reference No.: Q02241148 Submitted By: Lauren Inman Model Number: MMD24E7XHSDF Qty: 1 Condensing Model Number: PFH027A-PL7 Qty: 1 ELECTRICAL SUPPLY REQUIREMENTS Module: 277 Volts, 1 Phase, 60 Hz, 33.3 Full Load Amps, 41.6 Wire Sizing Amps, 45 OPD Cond: 208/230 Volts, 1 Phase, 60 Hz, 13.4 Full Load Amps, 16.4 Wire Sizing Amps, 25 OPD NET CAPACITY DATA 72ºF (22.2ºC) DB -- 60ºF (15.5ºC) WB -- 50% RH Total – 21,200 Btuh (6.20 kW) Sensible – 17,800 Btuh (5.20 kW) EVAPORATOR FAN Direct Drive Motor, 0.5 HP (0.3 kW) Air Volume - High Speed: 885 CFM (1504 CMH) Air Volume - Low Speed: 800 CFM (1359 CMH) External Static Pressure: 0.3 Inches of Water (8 mm) REHEAT SECTION SCR Reheat: 24,900 Btuh (7.3 kW) Includes Fan Motor HUMIDIFIER SECTION Steam Generator – Capacity: 4.3 lbs/hr (1.5 kg/hr) 1.5 kW CONDENSING UNIT Design Ambient: 95ºF (35ºC) Outdoor Propeller Fan (Lee-Temp Head Pressure Control) Condensing Unit Hot Gas Bypass Capacity Control Factory Installed Options Non-Locking Disconnect Switch High Temperature Sensor Smoke Sensor PG2 Rev 10/10 Ship-Loose Accessories Sweat Adapter Kit Filter Box with 4” MERV 8 Filters 277 Volt Condensate Pump PG3 Rev 10/10 LIEBERT MINI-MATE2 1-3 TON SYSTEMS WALL MOUNTED MICROPROCESSOR CONTROL AND MONITOR GENERAL BUTTON CONTROL allows full function modification of all running parameters. The 8 key membrane keypad includes on/off, fan speed, menu, alarm silence, increase, decrease, escape & enter. DISPLAY A 2 line x 16 character LCD which displays all monitoring, control, alarm, and diagnostic information. ALARMS are displayed on the LCD display with audible alarm. COMMON ALARM connections are provided at unit-mounted interface board for remote annunciation of unit alarms (compatible with SITE SCAN). STANDARD ALARMS TEMPERATURE high and low thresholds are programmable between 35 °F and 95 °F (1.6 °C and 32.2 °C). The alarm indicates excessive high or low room air temperature. HUMIDITY high and low thresholds are programmable between 15% RH and 85% RH. The alarm indicates excessive high or low room air humidity. HIGH HEAD Indicates a head pressure above factory preset point, and provides compressor cutout. SHORT CYCLE ALARM Indicates the compressor has turned off-on-off at least 10 times in a one hour period. LOSS OF POWER Indicates that a power interruption has occurred. HIGH WATER ALARM Indicates high water level in condensate pan, and shuts down unit. OPTIONAL ALARMS The following alarms are available when the appropriate options are included with the unit. A maximum of two(2) alarms from the list below. Change Filters Indicates that the pressure drop across the filters has exceeded the pre-set level. Humidifier Problem Indicates excessive high water levels in the humidifier canister. Water Detected Indicates that water has been detected at a customer specified location. Smoke Detected Indicates that smoke has been detected, and unit shutdown. Alarm does not function as or replace any room smoke detection system that may be required by local or national codes. FEATURES OF THE MONITOR MONITOR Room conditions, operating status, alarms. SET-UP Password protected programming of various time delays and unit configurations. SETPOINT Password protected programming of operational setpoints/alarms. 5 DAY/ 2 DAY PROGRAMMABILITY 2 changes per day for temperature and humidity control setpoints. TEMPERATURE AND HUMIDITY SENSOR CALIBRATION can be adjusted from ±5 °F/±10% RH to match local measuring device. DPN000178 REV 7/11 REV 3 SMALL SYSTEMS 2 & 3 TON MINI-MATE2 UNIT PIPING DATA AIR, WATER/GLYCOL & CHILLED WATER Entrance For Customer High Volt Connections. FRONT OF UNIT Entrance For Customer High Volt Connections With (SPPK) Single Point Power Kit. Evaporator Air Inlet on Ducted Version. Filter Clog Switch Option Connection Point Entrance For Customer Low Volt Connections 3/4" NPT Female Condensate Drain connection. Drain is Trapped Internally And Must Not beTrapped Outside of The Module. 7/8" (22.2mm) Dia. Entrance For Low Voltage Connection to Condensing Unit (if applicable) Hot Water Reheat 5/8" (15.9mm) OD CU or Free Cooling Outlet 7/8" (22.2mm) OD CU. Extends 3-1/2" (88.9mm) beyond panel exterior. Hot Water Reheat 5/8" (15.9mm) OD CU or Free Cooling Inlet 7/8" (22.2mm) OD CU. Extends 3-1/2" (88.9mm) beyond panel exterior. Chilled Water Supply Line(IN) 7/8" (22.2mm) OD CU Extends 3-1/2" (88.9mm) beyond panel exterior. Chilled Water Return Line(OUT) 7/8" (22.2mm) OD CU Extends 3-1/2" (88.9mm) beyond panel exterior. Single Point Power Kit (SPPK) Harness Connection From Condensing Unit Evaporator Air Outlet on Ducted Version Optional 1/4" O. D. compression Fitting. Use Copper Lines For Humidifer Supply Line NOTE: ROUTE SUPPLY LINE TO CLEAR HANGING RODS. BACK OF UNIT 7/8" Dia. (22.2mm) Electrical Entrance for Condensate Pump Connection. Suction Refrigerant Line Quick Connect Female Coupling with Access Valve Evaporator Air Outlet For Plenum Version Power Supply from Electric Service Power Block in Fan/Coil Module. Fan/Coil Unit Air Outlet Duct Drain Line (Field Supplied) Condensate Drain CONDENSATE PUMP (FIELD INSTALLED) ON UNIT WITH AIR OUTLET DUCTWORK DPN000192 Drain Line (Field Supplied Power Supply from Electric Service Power Block in 3/4" Hose Barb Fan/Coil Condensate Pump Supplied on Module Pump Tank Flexible Rubber Tubing 3/4" Hose Barb Supplied on Pump Tank Flexible Rubber Tubing 3/4" FPT Customer Connection Field Supplied Rigid Piping (Support as Required) Evaporator Air Inlet For Plenum Version Fan/Coil Unit Condensate Pump Condensate Pump Support Brace Liquid Refrigerant Line Quick Connect Female Coupling with Access Valve 3/4" FPT Customer Connection Condensate Condensate Drain Pump Support Field Supplied Brace Rigid Piping (Support as Required) CONDENSATE PUMP (FIELD INSTALLED) ON UNIT WITH AIR DISTRIBUTION PLENUM Note: 3/4" (19.1mm) Flexible Rubber Tubing Assembly (Supplied with Pump Kit) must be installed on pump end of rigid piping (Support as Required.) REV 09/09 REV 1 SMALL SYSTEMS 2 & 3 TON MINI-MATE2 ELECTRICAL FIELD CONNECTIONS Remote Control Panel Connection to TB3-1,2,3,4 connected with field supplied Thermostat wire (22ga, shielded/ jacketed: available from Liebert or others). Unit Control Board terminals marked GND, +5V, T-, T+ must be connected to corresponding terminals on Remote Control Wall Box. Common alarm connection. Field supplied 24V. Class 2 wiring to common alarm conn TB1-6 & TB1-7. Site monitoring connection. Terminals TB4-1(+) TB4-2(-) are for connection of a 2 wire. twisted pair, communication cable (available from Liebert or others) to optional sitescan. Customer remote alarm connection field supplied 24V. Class 2 wiring to conn TB1-1, TB1-2 & TB1-3. Remote unit shutdown. Replace existing jumper between terminals TB1-4 & TB1-5 with normally closed switch having a minimum 75VA rating. use field supplied 24V class 1 wire. (Optional) condensate pump aux float switch connection to term TB1-8 & TB1-9. ** 16 AWG Field supplied unit disconnect switch when factory unit disconnect switch is not supplied Heat rejection connection. Field supplied 24V NEC class 2 wiring. See note 2. For remote air cooled units from terminals TB2-1, 2, 3 & 4 in the Fan/Coil module to wires 1, 2, 3 & 4 in the condensing module: 1. 24V GND 2. 24V Supply 3. High Pressure Alarm (OPT) 4. Hot Gas Bypass Connection Earth ground connection Connection terminal for field supplied earth grounding wire. Entrance for customer low volt connections. Remote Humidifier Contact Field Supplied 24V class 2 wiring to terminals 11 & 12, located in field wire compartment. High Volt Power Connections. Electric service connection terminals. Factory installed disconnect switch. Electric service not by Liebert Entrance For Customer High Volt Connections. Electrical entrance for optional condensate pump Drycooler/Circulating pump control circuit TB70-71. Optional w/Econ-O-Cycle models. Use field supplied 24V class 2 wire. Field supplied, field wired thermostat wire to remote wall box NOTES: 1.Refer to specification sheet for full load amp and wire size amp ratings. 2.Control voltage wiring must be a minimum of 16GA (1.3mm) for up to 75' (23m) or not to exceed 1 volt drop in control line. Entrance For Customer Low Voltage Connections Field supplied 24V (NEC class 2 wiring) to condensing module. (if applicable) DPN000195 REV 12/09 REV 2 SMALL SYSTEMS 2 & 3 TON MINI-MATE2 FAN/COIL MODULE DIMENSIONAL DATA AIR, WATER/GLYCOL & CHILLED WATER WITH DIRECT DRIVE BLOWER 1 7/16" (37mm) CUSTOMER SUPPLIED 30" THREADED RODS FOR (762mm) MODULE SUPORT FROM CABINET CEILING (TYP. 4) DIMENSION 3 7/8" (98mm) 1" (25.4mm) 11" (279mm) 15" (381mm) 24" (610mm) CABINET DIMENSION 20" (508mm) 18" (457mm) 27 13/16" (706mm) THREADED ROD CENTERS 11 1/8" (283mm) 14" (356mm) REMOVABLE ACCESS 1 7/16" PANELS (37mm) 18" (457mm) 54" (1372mm) 57 13/16" CABINET (1468mm) DIMENSION OVERALL 55 13/16" DIMENSION (1418mm) THREADED ROD CENTERS SHADED AREA INDICATES A RECOMMENDED CLEARANCE OF 30" (762mm) BE PROVIDED FOR ACCESS AND FILTER REMOVAL 18" (457mm) 14" (356mm) CABINET OUTLINE 11 5/8" (295mm) 1" (25.4mm) (OPTIONAL) FILTER BOX 7/8" (22mm) HOLES FOR MODULE RIGGING (TYP. 2 EACH END). NOTE: UNIT IS SPACED EVENLY IN REFERENCE TO THREADED ROD CENTERS SHADED AREA INDICATES A RECOMMENDED CLEARANCE OF 30" (762mm) BE PROVIDED FOR COMPONENT ACCESS AND REMOVAL MODULE DIMENSIONAL DATA CABINET DIMENSIONS SAME AS ABOVE. COVER PLATE SUPPLIED WITH PLENUM. REMOVABLE PANEL ON SIDE OF PLENUM. MINIMUM CLEARANCE 30" (762mm) FOR FLTER ACCESS AND REMOVAL. 18" (457mm) 14" (356mm) 19 7/8" (505mm) 3/4" (19mm) (OPTIONAL) DISCHARGE AIR DUCT FLANGE SUPPLIED WHEN (OPTONAL) FILTER BOX IS ORDERED. 18" (457mm) HANGING BRACKET DUCT FLANGE 10 7/8" (276mm) UNIT NET WEIGHT MODEL # 60 HZ 50 HZ LBS MM*24E NA 225 MM*36E MM*35E 225 MM*40C MM*39C 230 (KG) (102) (102) (104) 6" (152mm) 5" (127mm) 48" (1219mm) OVERALL DIMENSION AIR DISCHARGE OUT SIDES OF PLENUM. 3.25" (83mm) 24" (610mm) OVERALL DIMENSION AIR DISCHARGE OUT SIDES OF PLENUM. AIR INLET THROUGH GRILL IN CENTER OF PLENUM. (OPTIONAL) AIR DISTRIBUTION PLENUM ALL PIPING & ELECTRICAL FIELD CONNECTIONS ARE THE SAME DPN000193 REV 04/11 REV 3 SMALL SYSTEMS 2-ton and 3-ton MINI-MATE2 DIRECT EXPANSION FAN/COIL MODULE STANDARD FEATURES EVAPORATOR COIL Constructed of copper tubes in a staggered tube pattern. Tubes are expanded into continuous high efficiency aluminum lance type fins. Coil is set in condensate drain pan, with float switch for unit shutdown. REFRIGERATION SYSTEM Single refrigeration circuit, includes a liquid line filter drier, externally equalized expansion valve, and a quick-connect female coupling on both the suction and liquid lines. Each female coupling is provided with an access valve connection. The module is precharged with refrigerant and sealed. FAN ASSEMBLY Centrifugal type, double width, double inlet, with a direct drive 2-speed fan motor mounted to the blower housing and includes lifetime lubricated bearings. CONTROLS Microprocessor based design includes 8 key membrane key pad for setpoint and program control, unit on/off, and fan speed mounted in a decorative wall box for remote mounting. CABINET AND CHASSIS Constructed of galvanized steel for strength and corrosion resistance with thermal/acoustical insulation to reduce sound levels and prevent condensation. Removable panels allow access to the electric panel or refrigeration components for service or maintenance. Vibration isolators are provided with the chassis for mounting. UNIT DISCONNECT SWITCH Consists of a “non-locking type”, non-automatic molded case circuit interrupter mounted inside the unit, with handle accessible outside cabinet. DPN000186 REV 09/11 REV 4 SMALL SYSTEMS 2-ton and 3-ton LIEBERT MINI-MATE2 DIRECT EXPANSION FAN/COIL MODULE OPTIONAL FEATURES (Split DX Systems) ELECTRIC REHEAT Electric low watt density 304 stainless steel fin tubular reheat element provides one stage of reheat to maintain room dry bulb temperature. SCR ELECTRIC REHEAT includes integral controller and sensor to provide modulating electric reheat. STEAM GENERATING CANISTER HUMIDIFIER is housed in a steel enclosure and includes a replaceable canister with integral fill cup, fill and drain valves, and high water indicator. System automatically fills and drains as well as maintains the required water level based on conductivity. HIGH TEMPERATURE SENSOR is mounted in the unit with the sensing element in the return airflow. Upon activation, the high temperature stat will immediately shut down the entire unit. SMOKE DETECTOR the smoke detector senses the return air, shuts down the unit upon detection, and sends visual and audible alarm. This smoke detector is not intended to function as or replace any room smoke detection system that may be required by local or national codes. FILTER CLOG SWITCH activates the alarm system when the pressure drop has exceeded the customer-set level. FREE COOLING is factory piped with a control valve, free cooling coil is constructed of copper tubes and aluminum fins. Coil is designed for closed-loop applications using properly treated and circulated fluid. Refer to installation manual for further guidelines. Not available with SCR reheat option. SHIP LOOSE OPTIONS PRECHARGED REFRIGERANT LINE SETS consist of one pre-charged liquid line and one pre-charged insulated suction line of soft copper tubing. Each line is pre-charged with R-407C refrigerant. Each line has one male quick-connect coupling and one female quick-connect coupling with an access valve connection. Line sets are available in 15 ft. (4.6 m) and 30 ft. (9.1 m) lengths for interconnection of remote condensing units. Maximum recommended line-set distance is 45 ft. (13.7 m). FILTER BOX is constructed of galvanized steel, supplied with a nominal 16”(406mm) x 20”(508 mm) x 4” (102 mm) deep pleated MERV 8 filter (based on ASHRAE 52.2-2007). The box is provided with a ¾” (19 mm) duct flange. The filter is accessible via a hinged access door, without shutting the unit down. The filter box option also includes a ¾” (19 mm) discharge air duct collar. CONDENSATE PUMP has a capacity of 80 GPH (303 l/h) for 230 volt 60 Hz units and 74 GPH (279 l/h) for 208/277 volt 60 Hz units or 56 GPH (212 l/h) for 220 Volt 50 Hz units at 10 ft. (29 kPa) of head. Pump is complete with pump, motor assembly, reservoir, integral float switch, and auxiliary safety float switch to shut unit off in event of pump failure. Pump assembly is designed to mount on the right side of the evaporator (indoor) module, or other suitable means to allow condensate drainage into the reservoir. REMOTE TEMPERATURE AND HUMIDITY SENSORS include sensors mounted in an attractive case with 30 ft.(9m) of cable. SWEAT ADAPTER KIT Contains two suction and two liquid compatible fittings that allow field-supplied interconnecting refrigerant lines to be used. See installation, operation and maintenance manual for maximum recommended installed distances. AIR DISTRIBUTION PLENUM Easily installed, self-contained air distribution plenum provides air discharge in three directions. The plenum is supplied with a nominal 16” (406mm) x 25” (535mm) x 4” (102mm) deep pleated MERV 8 filter (based on ASHRAE 52.2-2007). SINGLE POINT POWER KIT Allows modules to be connected to a single power feed when the evaporator and condenser modules are closed coupled. OPTIONAL HIGH STATIC BLOWER ASSEMBLY Centrifugal type, double inlet, with a belt drive 1 speed fan motor mounted to an adjustable motor base, and includes ball bearings on both motor and blower. Higher duct static pressures are attainable up to 2.0” (51 mm) ESP down stream from unit. DPN000187 REV 07/11 REV 3 SMALL SYSTEMS 2 & 3 TON MINI-MATE2 GENERAL ARRANGEMENT DIAGRAM SPLIT SYSTEMS AIR & CHILLED WATER FAN COIL Condenser Coil High Pressure Switch Scroll Compressor AIR COOLED Liquid Injection Valve Bulb (Split System) Hot Gas Bypass Solenoid Valve Suction Line Male Quick Connect Coupling Suction Line Female Quick * Connect Coupling 3 - Way Head Pressure Relief Valve Hot Gas Bypass Control Valve Sensing Bulb External Equalizer 3/8" SAE 45° Male Flare (MCD) or Atmospheric (PFH) Pressure Relief Valve Check Valve Sight Glass Liquid Injection Valve Liquid Line Solenoid Valve Service Access Ports * Liquid Line Male Quick Connect Coupling Liquid Line Female Quick Connect Coupling Receiver Heater Pressure Limiting Switch Lee - Temp Receiver Pressure Balancing Valve Filter Drier Expansion Valve Bleed Valve Evaporator Coil CHILLED WATER Chilled Water Chilled Supply Water Return Chilled Water Control Valve Chilled Water Coil 3 - Way Chilled Water Control Valve (Optional) ** Shut - Off Valves ** Hose Bibs * Use Liebert sweat adapter kit with field hard piping or use Liebert pre-charged line set. Close-coupling option available with MCD. ** Components are not supplied by Liebert but are required for proper circuit operation and maintenance. DPN000191 SHEET 1 OF 1 FIELD PIPING FACTORY PIPING REV 06/14 REV 3 PROP FAN CONDENSING MODULES STANDARD FEATURES COMPRESSOR The 1½ - 8 ton PFH condensing units shall have a compliant scroll compressor with a suction gas cooled motor, vibration isolators, thermal overloads, internal centrifugal oil pump for forced feed lubrication, a maximum operating speed of 3500 RPM @ 60 HZ (2900 @ 50 HZ). The 1 ton PFH condensing unit shall have a reciprocating hermetic compressor. The 8 ton PFH is a dual compressor design with 3 ton and 5 ton compressors. CONDENSER COIL Constructed of copper tubes in a staggered tube pattern. Tubes are expanded into continuous high efficiency aluminum plate type fins. Coil is set in a drain pan for condenser coil washdown. REFRIGERATION SYSTEM Single refrigeration circuit, includes, suction and liquid line quick connect male couplings. The module is precharged with refrigerant and sealed. The 8 ton PFH includes two refrigeration circuits. HOT GAS BYPASS Factory piped hot gas solenoid valve and pressure regulating valve work in conjunction with a thermostatic liquid injection valve. This system allows operation down to zero load on the evaporating (indoor) module. Both circuits on the 8 ton model receive HGBP. FAN ASSEMBLY Consists of propeller type blades, constructed of zinc plated steel or aluminum, secured to the motor shaft by a heavy duty hub with set screws. Direct drive fan motors are provided with rain slingers, lifetime lubricated bearings, and internal overload protection. CABINET AND CHASSIS Designed for outdoor use with either roof or ground level mounting. The condensing module is constructed of galvanized and galvaneal painted steel for corrosion resistance. Both inlet and outlet air grilles are heavy duty steel with a durable P.V.C. coating. Removable exterior panels allow access to the electric panel or refrigeration components for service or maintenance. HEAD PRESSURE CONTROL A Liebert Lee-Temp control system is furnished with each refrigeration circuit and consists of an insulated heated refrigerant receiver with sightglass, pressure relief valve, pressure balancing valve, check valve, and head pressure operated 3-way valve. This system allows operation at ambient conditions as low as -30 °F (-34 °C). OPTIONAL FEATURES QUIET LINE Oversized cabinet, low speed 6-pole motor, and Liebert fan blade design combine to achieve the quietest unit available(8 to 10 dB(A) below standard models). Not available on 8 ton PFH. HIGH AMBIENT Oversized condenser coil with high efficiency aluminum plate type fins and increased airflow. Designed for operation at ambient conditions of 105 °F (40 °C) with no reduction in evaporator rated performance. Not available on 8 ton PFH. DPN000128 REV 04/11 REV 3 GENERAL PIPING ARRANGEMENT PROP FAN CONDENSING MODULE SINGLE CIRCUIT = 1 - 5 Tons DUAL CIRCUIT = 8 Tons Condenser Coil High Pressure Switch Compressor * Liquid Injection Valve Bulb Hot Gas Bypass Solenoid Valve Atmospheric Pressure Relief Valve Suction Line Male Quick Connect Coupling Hot Gas Bypass Control Valve 3 - Way Head Pressure Control Valve Sight Glass Check Valve Liquid Injection Valve Liquid Line Solenoid Valve Lee - Temp Receiver Receiver Heater Pressure Limiting Switch Liquid Line Male Quick Connect Coupling * Reciprocating compressor 1 Ton. Scroll compressor 1 1/2 - 8 Tons. DPN000129 Pressure Balancing Valve SINGLE CIRCUIT SHOWN REV 04/11 REV 3 CABINET AND FLOOR PLANNING DIMENSIONAL DATA PROP FAN CONDENSING MODULES HORIZONTAL AIR DISCHARGE REMOVABLE (RIGHT) PANEL FOR ACCESS TO REFRIGERATION COMPONENT. Fan Rotation CCW (left side) A RIGHT AIR DISCHARGE LEFT AIR INTAKE SHADED AREA INDICATES A MINIMUM CLEARANCE OF 18" (457mm) BE PROVIDED FOR PROPER AIR FLOW. B C SHADED AREA INDICATES A MINIMUM CLEARANCE OF 18" (457mm) BE PROVIDED FOR PROPER AIR FLOW. MODEL NUMBERS 60 HZ 50HZ PFH014A-L NA PFH020A-L NA PFH027A-L NA PFH027A-H NA PFHZ27A-L NA PFH037A-L PFH036A-L PFH042A-L PFH041A-L PFH037A-H PFH036A-H PFHZ37A-L PFHZ36A-L PFH042A-H PFH041A-H PFHZ42A-L PFHZ41A-L PFH067A-L PFH066A-L DPN000130 REMOVABLE (FRONT) PANEL FOR ACCESS TO HIGH VOLTAGE & LOW VOLTAGE CONNECTIONS, AND REFRIGERATION COMPONENTS. DIMENSIONAL DATA IN. (mm) A B C SHADED AREA INDICATES A RECOMMENDED CLEARANCE OF 24" (610mm) BE PROVIDED FOR COMPONENT ACCESS AND REMOVAL. MODULE WEIGHT lbs. (kg) net. 40 (1016) 23 1/2 (597) 18 (457) 200 (91) 48 (1219) 31 (787) 18 (457) 241 (109) 53 (1343) 36 1/4 (918) 18 (457) 351 (159) REV 04/11 REV 1 PIPING AND ELECTRICAL CONNECTIONS HORIZONTAL AIR DISCHARGE Liquid Line Quick Connect (Male Coupling). Suction Line Quick Connect (Male Coupling). Except as noted A G F Electrical Entrance for High Voltage Connection. B C Electrical Entrance for Low Voltage Connection. D E MODEL NUMBERS 60 HZ 50 HZ PFH014A- L PFH020A- L PFH027A- L NA NA NA PFH027A- H NA NA PFHZ27A- L PFH037A- L PFH042A- L PFH037A- H PFHZ37A- L PFH042A- H PFHZ42A- L PFH067A- L DPN000132 PFH036A- L PFH041A- L PFH036A- H PFHZ36A- L PFH041A- H PFHZ41A- L ELECTRICAL CONNECTIONS IN. (mm) A C B 2 1/4 (57) 5 1/4 (133) 7 3/4 (197) D 8 3/4 (222) PIPING CONNECTIONS IN. (mm) G F E - 5 (127) 7 1/4 (184) 2 (51) 5 3/4 (146) 8 1/2 (216) 4 3/4 (121) 6 3/4 (171) - 8 1/2 (216) 2 (51) 6 (152) 8 1/2 (216) 4 3/4 (121) 7 3/4 (197) - 8 1/2 (216) PFH066A- L REV 04/11 REV 1 ELECTRICAL FIELD CONNECTIONS 1 – 5 TON PROP FAN CONDENSING MODULE Field supplied unit disconnect switch. Single or three phase electric service not provided by Liebert. Single or three phase electric service not provided by Liebert. Field supplied unit disconnect switch. Field supplied 24V NEC class 2 wiring to evaporator module. Horizontal Air Discharge Models Field supplied 24V NEC class 2 wiring to evaporator module. Top Air Discharge Models (5 ton High Ambient or 5 ton Quiet-Line) Electric service connection to contactor or terminal block. Factory wired to components on electric panel. Single or three phase electric service not provided by Liebert. High voltage electric power supply entrance. Low voltage electric power supply entrance. Earth ground connection terminal for field wiring. ** 16 AWG Heat rejection connection. Field supplied 24V NEC class 2 wiring. Wire connections from evaporator module: 1 24V GND 2 24V Supply 3 High Pressure Alarm 4 Hot Gas Bypass Connection NOTE: Refer to specification sheet for full load amp. and wire size amp. ratings DPN000134 REV 01/09 REV 1