GPI-U116N - Inter-M

advertisement
Universal General Purpose Input device server
GPI-U116N
GPI-U116N_BR_E_1502_V1.indd 1
15. 2. 2. 오후 3:47
VV
SUMMARY
The GPI-U116N is a universal, versatile general-purpose-to-network interface. It is a fully functional stand-alone IP-to-I/O
remote access controller with internal web server. It functions as a remote expansion port for Inter-M’s integration systems.
The GPI-U116N is the ideal solution for providing LAN based control for devices needing I/O functionality.
OVERVIEW
The GPI-U116N is a universal, versatile general-purpose-to-network interface. It is a fully functional stand-alone IP-to-I/O
remote access controller with internal web server. Housed in a in a 1RU form factor it is designed for all types of commercial
AV installations. It functions as a remote expansion port for Inter-M’s Integration systems. Using standard TCP/ IP Ethernet
network, it is remotely controlled via the network and can be placed anywhere in a facility. The GPI-U116N is the ideal solution
for providing LAN based control for devices needing I/O functionality.
Signal Monitoring is available for all 16 inputs with a front panel mounded LEDs, indicating active input triggers. Power and
fault LED indicators confirm proper device operation.
General Purpose Contact Input
GPI-U116N_BR_E_1502_V1.indd 2
15. 2. 2. 오후 3:47
GENERAL PURPOSE
CONTACT INPUT
Brand Interoperability
Based on industry standards, TCP/IP network protocol the GPI-U116N can receive TCP/IP command
packets from any network devices connected to a LAN or WAN. Interoperability is a reality today.
The Inter-M GPI-U116N is compatible with hundreds of other Network-enabled products available
from the world’s leading manufacturers, enabling you to mix devices from multiple manufacturers.
Tunneling contact closures over IP
The GPI-U116N works as a reliable intermediate between host based data devices and control
applications, tunneling contact closures over IP. The device provides 16 dry contact input terminals
receiving trigger inputs from external devices via one network. The host interface supports industrystandard TCP/IP protocols. The GPI-U116N is a portal for controlling or monitoring devices across your
facility or across the world
Network Connectivity
One 10/100 Ethernet port supports TCP/IP protocols. IT as well as automation systems can easily
connect to the device on a LAN or WAN network. TCP/IP, traffic can be routed over internal LANs,
wireless LANs, MANs, WANs and even over the Internet. Systems and devices in different locations,
floors building, and cities anywhere in the world are easily send a trigger or be monitored by GPI,
General Purpose Inputs over networks using the GPI-U116N.
Scalability
Receiving and monitoring contact closure control inputs from any systems is now possible with the
GPI-U116N. Any number of GPI-U116N can be added to a system expanding the number of contact
closure control inputs to the installations specific requirement.
General Purpose Contact Input
GPI-U116N_BR_E_1502_V1.indd 3
15. 2. 2. 오후 3:47
VV
Web-browser Control Panel
The GPI-U116N is easily configured using the built-in Web-browser interface. The Web-browser
control panel is a web-based interface (control panel), used to interact directly with the device,
both for making configuration changes and for requesting device information.
The Web-browser control runs directly on the device’s internal web server on port 80 and can be
accessed from any regular browser including web-enabled devices such as tablets and smart
phones.
You can access Web-Browser Control panel interface by opening a browser and typing
http://device_ip_address. The default IP address is http:// 192.168.1.99.
The web-browser interface will allow you to setup and configure the Network Settings, Security,
Date/Time, Activate the Trigger channel, Firmware Update, Maintenance and Log Files. Through
the web-browser interface, you can easily trigger a relay remotely and verify its status.
Emergency Power and Battery Charging
The simultaneous dual redundant AC and DC power operation, offers uninterrupted operation in
the event of an AC mains power outage. If the main AC power fails, the GPI-U116N automatically
switches to the DV24V battery backup.
General Purpose Contact Input
GPI-U116N_BR_E_1502_V1.indd 4
15. 2. 2. 오후 3:47
GENERAL PURPOSE
CONTACT INPUT
FEATURE
•16 Dry Contact input
•16 Status LED
•10/100 TCP/IP Network connectivity
•Power and Fault Indicators
•Web-browser control and configuration
•AC & DC dual power operation.
•1U size
SPECIFICATION
GPI-U116N
16 status LED
Yes
Power / Fault indicators
Yes
Power soure
DC24V ±20%, 160mA
Operating temperatuer / humidity
0℃ ~ +40℃ / 90%
Wegit (SET)
3.54kg
Dimentions (SET)
440(W) x 44(H) x 280(D) mm
APPLICATION
Applications include adding remote system monitoring Receiving contact closure control inputs
for device triggering and remote notification over IP. The GPO-U116N will add additional dry
contact trigger control to Inter-M solutions like the ARM-911, the system 6000 or simply used as a
stand-alone network device. It can be used in buildings, wiring cabinets, server rooms, airports,
railway stations, ground transportation, and anywhere remote contact control is required over long
distances. The GPI-U116N will easily integrate contact closure control for your entire system over a
single, standard IP network.
General Purpose Contact Input
GPI-U116N_BR_E_1502_V1.indd 5
15. 2. 2. 오후 3:47
VV
RELATED PRODUCTS
•GPO-U116N
•AOE-212N
•DAC-288
•ARM-911
•6000 System
APPICATION Notes
1.Expand Input Trigger of ARM-911
GPI-U116N
CS-20
(SPEAKER)
ARM-911
Network Switch
DPA-300S
RM-911D
Sixteen (16) external contact triggers connected to the ARM-911 to control the broadcast of the
emergency messages from a remote location anywhere in different locations, floors building, and
cities anywhere in the world over any standard TCP/IP LAN/WAN network.
Ideal for schools, office buildings, hotels. apartments, factories and retail.
General Purpose Contact Input
GPI-U116N_BR_E_1502_V1.indd 6
15. 2. 2. 오후 3:47
GENERAL PURPOSE
CONTACT INPUT
2.Add and Expand remote Input Trigger of 6000 System
6000INPUT TRIGGER EXPANSION WITH GPI-U116N
CS-20
(SPEAKER)
GPI-U116N
TCP/IP
AUDIO
Network Switch
TCP/IP
PX-6216
RS-485
ECS-6216
DIB
USB
RM-6024
Multiple GPI and GPO devices can easily connect to the device on a LAN or WAN network. TCP/IP, traffic can
be routed over internal LANs, wireless LANs, MANs, WANs and even over the Internet. Systems and devices in
different locations, floors, building, and cities anywhere in the world are easily send a trigger or be monitored by
GPI/GPO, General Purpose Inputs and outputs over networks using the GPI-U116N and GPO-U116N.
3.Remote monitoring and receive dry contact general-purpose control from devices over long distances using
TCP/IP Network Connectivity.
Expending I/O triggers unput over TCP/IP LAN/WAN Internet
GPI-U116N
CS-20
(SPEAKER)
ARM-911
Network Switch
TCP/IP
AUDIO
DPA-300S
GPI-U116N
RS-485
Ethernet
RM-911D
GPI-U116N
GPI-U116N
Multiple GPI and GPO devices can easily connect to the device on a LAN or WAN network. TCP/IP, traffic can
be routed over internal LANs, wireless LANs, MANs, WANs and even over the Internet. Systems and devices in
different locations, floors, building, and cities anywhere in the world are easily send a trigger or be monitored by
GPI/GPO, General Purpose Inputs and outputs over networks using the GPI-U116N and GPO-U116N.
General Purpose Contact Input
GPI-U116N_BR_E_1502_V1.indd 7
15. 2. 2. 오후 3:47
Inter-M Corp. (IMK)
719, Dobong-ro, Dobong-gu, Seoul, Korea
Overseas Sales Team
Tel_ +82-2-2289-8141~7 Fax_ +82-2-2289-8149
E-mail_ overseas@inter-m.com
※ Design and specification are subject to be changed for the improvement of product quality without pre notice.
GPI-U116N_BR_E_1502_V1.indd 8
www.inter-m.com
2015. 2. V1
15. 2. 2. 오후 3:47
Download