DC POWER SYSTEM DCPS 12KW WITH DISTRIBUTION The La Marche DCPS system offers a complete DC power solution in a compact package configuration (4RU). DCPS system can be installed in standard 19 or 23 inch rack or cabinet. La Marche DC system utilizes high efficiency rectifiers, a highly intelligent system controller, I/O interface board for alarms/ sensors, and a load/battery distribution panel. This complete DC system offers battery management with low voltage disconnect, remote monitoring, remote configuration and configurable alarm contacts. The compact design of the system reduces space requirements and installation cost. The system is configured with 48V/50A high efficiency rectifiers to provide a rated output current up to 200A. The DC distribution section is comprised of 16 pluggable load breakers and 2 battery breakers. Standard Features Universal AC Input Hot-Swappable Rectifiers Provide Easy Installation and Maintenance Rectifier Efficiency Exceeds 96% (Lower Energy Consumption) Rectifier Hibernation Management Mode (Increases System Efficiency) Intelligent Battery Management and Protection Modes Site Environment Monitoring and Remote Management (Through Dry Contacts, Serial Interface or Ethernet Interface) 16 Pluggable Load Breakers, 2 Battery Breakers and LVBD (Low Voltage Battery Disconnect) 50A Rectifier (56A @ 53.3V) UL Recognized Controller La Marche Mfg. (A U.S. Company) Specifications subject to change without notice P25-DSDCPS4-1 ECN 21098 4/16 106 Bradrock Drive, Des Plaines, IL 60018 Tel: 847.299.1188 Fax: 847.299.3061 sales@lamarchemfg.com www.lamarchemfg.com Specifications RECTIFIER Input Voltage 85-300 VAC, Single Phase Input Frequency 45-66 Hz Maximum Input Current 17A Output Voltage 42-58 VDC, Nominal: 54 VDC Efficiency Rated Power >96% 56A @ 53.3V (176-300 VAC) Linearly derated to 23A @ 53.3V (85-175 VAC) 4.1” x 11.1” x 1.6” (1RU) 105 x 281 x 40.8mm Dimensions (W x D x H) DC DISTRIBUTION CONTROLLER MECHANICAL ENVIRONMENTAL www.lamarchemfg.com Weight ≤4.4lb (≤2kg) Cooling Mode Forced Air Cooling Power Factor ≥0.99 THD ≤5% Maximum Capacity 220A @ Nominal Battery Breakers 2 x up to 200A Breakers Load Breakers A group: 8 x up to 100A Breakers B group: 8 x up to 100A Breakers Low Voltage Battery Disconnect Adjustable Surge Protection Device (SPD) 10kA/20kA, 8/20µs Display Mode LCD Available Signal Input 6 Digital Inputs, 1 Door Sensor, 1 Water Sensor, 1 Smoke Sensor, 2 Temperature Sensors, 1 Battery Temperature Sensor, 1 Temperature/Humidity Sensor Alarm Output 8 Dry Contact Outputs Communication Ports RS232/485, Fast Ethernet (FE) Overall Dimensions (W x D x H) 19” x 17.7” x 7” (4RU) 482.6 x 450 x 178mm Weight (without rectifiers) ≤50.7lb (≤23kg) Cooling Natural Cooling Mounting 19” or 23” Rack Terminal Rear Access Protection Level IP20 Operating Temperature -40 to 65°C (-40 to 149°F) Storage Temperature Operating Humidity Altitude -40 to 70°C (-40 to 158°F) 5%-95% (Non-Condensing) Up to 6,562ft (Derate Operating Temperature by 1°C/656ft for 6,562ft-13,123ft) 2 CONTROLLER (DCSC) Controller Front Panel La Marche’s DC System Control (DCSC) is an intelligent module that monitors and manages La Marche DC power systems. The controller provides the system with Battery Management, Energy Conservation, Rectifier Management, Intelligent Battery Hibernation Mode, Battery Testing, Battery Charging, and Current Limiting controls. System configuration settings and real-time parameters can be accessed either locally (through a two-line LCD display), or remotely (through a Web User Interface). Communication Ports Communication Ports FE port RS485/RS232 port Communication Parameter Communication Protocol 10/100M auto-adaptation HTTPS and SNMP Baud rate: 9600 bit/s Master/slave protocols NOTE: All ports are protected by a security mechanism (1) Run Indicator (2) Minor Alarm Indicator (3) Major Alarm Indicator (4) Control Buttons (5) USB port DCU I/O INTERFACE MODULE (6) RS485/RS232 Port (7) Handle (8) Locking Latch (9) Fast Ethernet (FE) Port (10) LCD DCU Port Description Equipped with the I/O module (DCU), the controller supports configurable digital inputs, alarm dry-contacts and site sensor ports for environment management and alarms reporting. The DCU I/O module provides the ability to add multiple sensors for: ambient temperature, humidity, water, door status, smoke and battery temperature. Port Type Sensor Port The dry-contacts alarm are configurable and can be customized upon the DC system’s requirements. All alarms can be easily configured and monitored remotely through the WebUI (Web User Interface). See page 4 for details. Dry Contact Input NOTE: For details about the signal definitions, see the power system user manual Dry Contact Output NOTE: For details about the alarms associated with dry contact outputs, see the power system user manual Communication Port 3 Silk Screen Description TEM-HUM Ambient Temp. and humidity sensor WATER Water Sensor TEMP1 Ambient Temperature Sensor 1 TEMP2 Ambient Temperature Sensor 2 GATE Door Status Sensor SMOKE Smoke Sensor BTEMP Battery Temperature Sensor DIN1 Dry Contact Input 1 DIN2 Dry Contact Input 2 DIN3 Dry Contact Input 3 DIN4 Dry Contact Input 4 DIN5 Dry Contact Input 5 DIN6 Dry Contact Input 6 ALM1 Dry Contact Output 1 ALM2 Dry Contact Output 2 ALM3 Dry Contact Output 3 ALM4 Dry Contact Output 4 ALM5 Dry Contact Output 5 ALM6 Dry Contact Output 6 ALM7 Dry Contact Output 7 ALM8 Dry Contact Output 8 COM RS485 Port Controller Features DETECTION BATTERY MANAGEMENT AC Input Voltage Battery Hibernation AC Input Current Battery Control AC Frequency Battery Charging DC Output Voltage Total Load Current Battery Test Battery Current Limiting Total Battery Current Battery Current Battery Temperature Compensation . Battery High Temperature Protection Battery Temperature Ambient Temperature Multi-Mode & Multi-Level Disconnecting Protection Battery Imbalance Detection Ambient Humidity ENERGY CONSERVATION MANAGEMENT Battery Capacity Calculation/Backup Time Calculation Rectifier Hibernation ALARM RECTIFIER MANAGEMENT Internal Fault Rectifier Operation Information Rectifier Power-On/Off Control AC Phase Failure Rectifier Overvoltage Protection AC/DC Overvoltage/Undervoltage Load/Battery Fuse Break Battery Discharging Sequential Rectifier Startup Low Voltage Battery Disconnect (LVBD) MECHANICAL Battery Temperature High/Very High/Low/Very Low Rectifier Output Voltage and Current Limit Overall Dimensions: 7.6” x 1.6” x 3.9” (W x D x H) 194.3 x 40.8 x 99mm Weight: 3.3lb (1.5kg) Rectifier Failure Natural Cooling No Redundant Rectifiers Rectifier Communication Failure AC/DC Surge Protection Device (SPD) Failure Web User Interface The Web User Interface allows for a secure password protected remote access to the DC system for monitoring and control purposes. The WebUI provides system’s running parameters, active alarms and configurations. Various settings can be configured using the WebUI. Settings include: alarm parameters and configurations, rectifier management, battery management and communications settings. The WebUI provides flexible alarm configuration settings that includes a PLC (Programmable Logic Controller) programming tool. www.lamarchemfg.com 4 DC RECTIFIER (DCR) The DCR50 rectifier converts AC power to DC power and utilizes high performance features, such as high efficiency (>96%), high power density, walk-in start, complete protection and low noise. The output voltage of the rectifiers can be adjusted through the DCSC controller. The rectifier is hot swappable, providing easy installation and maintenance. Rectifier Max. Amp Input Voltage Output Voltage Max Input Current DCR50 56A @ 53.3 VDC 85-300 VAC 42-58 VDC < 17 A Performance for 50 Amp Rectifiers Output Feature 55 50 45 40 10 15 20 25 30 35 40 45 50 55 60 65 Current / A 100 98 96 94 92 90 88 86 84 82 80 3500 Power/W Voltage/V 60 5 Power Derating Curve Efficiency Curve 3000 2500 2000 1500 1000 20% 40% 60% 80% 100% 500 40 50 Load Rate 55 65 75 Temperature/℃ DC DISTRIBUTION PANEL (DCD) The DC distribution section is comprised of: • 16 pluggable Load Breakers (0 – 100 Amp) • 2 pluggable Battery Breakers (Up to 200 Amp) • LVBD circuit All breakers are equipped with a trip detection alarm, and can be sized based on the system requirements. Available Breaker Current Ratings: 1A, 2A, 3A, 5A, 10A, 15A, 20A, 25A, 30A, 35A, 40A 50A, 60A, 70A, 80A, 100A, 125A, 150A, 200A Breaker Positions Required: - 100A = 1 Position 1A = 2 Positions 125A - 200A 5 www.lamarchemfg.com MECHANICAL DCPS Front View (1) Distribution DCD 7.00” (2) Controller DCSC (3) I/O Board DCU (4) Open slots for rectifiers (rectifiers sold separately) 17.70” DCPS Top View without the Top Cover (1) Return positive busbar 19.00” (2) Wiring terminals for DC output power cables (3) Wiring terminals for battery cables 17.70” Ordering Information Model Number Description Max. Number in One System Available Range DCPS-200 Complete system without rectifiers or breakers --- --- DCR50 50Amp DC rectifiers 4 --- P4-ALELB-xxD1B Plug in bullet type breakers 16 Up to 100A P4-ALELB-xxD1B Plug in bullet type breakers 2 125A, 150A P4-ACELB-200D1B Plug in bullet type breakers 2 200A www.lamarchemfg.com 6