LOGIC BOARD KIT K001A5566 FOR MODELS SL575/SL585/SL595 NOTE: Before installing new logic board remove connectors J1,J4 and J5 and set off to the side. If logic board does not function properly after replacement, due to bad J1, J4 and J5 connectors, it may be necessary to reconnect the connectors. REMOVAL OF EXISTING PARTS 1. Disconnect power to operator. 2. Disconnect wire harness plug connectors from J1 (16-pin black connector), J2 (8-pin white & 3-pin white, hall effect) and J4 (2-pin black connector), on existing logic board. 3. Remove the (3) pan head screws and washers holding the logic board to the electrical enclosure and retain for reassembly of new board. 4. Remove logic board from the electrical box, leaving the existing spacers in place. To prevent possible SERIOUS INJURY or DEATH, disconnect electric power to operator BEFORE installing. ALL electrical connections MUST be made by a qualified individual. Accessory Terminal Block INSTALLATION OF NEW PARTS 1. Slide logic board into card guide. 2. Secure logic board in place with the screws and washers previously removed. 3. Reprogram logic board. Refer to owner's manual provided with the operator for programming instructions. 4. Proceed to programming instructions. 5. Reconnect power to operator. Logic Board SINGLE PHASE SCHEMATIC WARNING L2 (BK) (B) (W) (BK) (SEE NOTE 2) (W) B 3 A 3 (W) (W) 5 A 6 1 B 2 4 (PU) (SL595 RD) (BL) PRIMARY 2 A 1 6 B 5 (GY) SL595 GN) (BL/BK) (BK) 3 (BL/BK) (PU) (SL595 RD) 8 5 (BL) (YE) (SL595 WH) 3 2 1 (GY) (SL595 GN) 115V BRAKE SOLENOID (BK) 208V/230V MOTOR CONNECTION 4 MOTOR OVERLOAD (SEE NOTE 3) BLACK (SL595 ORANGE) (B) 1 (SEE NOTE 3) 2 8 5 (YE) (SL595 WH) 208/230V ONLY (S) (S) (BK) 4 4 (BK) (BK) O/L (BK) (W) 115V ONLY (BK) ON/OFF SWITCH 1 PHASE POWER IN (W) GROUNDED DUPLEX OUTLET (115V ONLY) L1 115V MOTOR CONNECTION (W) To protect against fire and electrocution: • DISCONNECT power BEFORE installing or servicing operator. • Replace ONLY with fuse of same type and rating. Fuse: 3AG, 3.2A, 120V, SLO-BLO (SEE NOTE 3) (BL/BK) (BK) 230V BRAKE SOLENOID (BK) (BL/BK) 115V ONLY (BL) (GN) (NOTE 4) 24VAC R1 R2 RADIO SIGNAL R3 R4 24V Sec. (SEE NOTE 1) FUSE 3.2A (BL) (TB 2) (100 db) (BL) (BL) (BK) (BK) (BL) (RD) (Y/BK) (BK) (BRN) (BK) (RD) (GY) GL CONTROL BOARD J2 PLUG J2-8 J2-2 RPM - IN RPM - SUPPLY RPM GND J2-9 J2-10 J2-11 (WH) (YE) (GN) 3 (PU) 2 (PU) (BRN) NC COM (OR) 1 NC COM (OR) A1 B (GY) A2 FREE EXIT LOOP HARNESS 8 9 10 PIN - 1,2,3,5 CAPPED 10 4 6 7 INTERRUPT (SAFETY) LOOP HARNESS 8 9 10 PIN - 1,2,3,5 CAPPED 10 A A2 (WH) (RD) RPM SENSOR (BK) CLOSE OPEN FIELD CONNECTIONS (Y/BK) (PU) SHADOW J1-2 (PU/WH) +24VDC J1-3 (Y/BK) CLOSE J1-4 (GN) STOP J1-5 (Y/BK) SOFT OPEN J1-6 (BRN) HARD OPEN J1-7 INT. LOOP J1-8 OBS. OPEN J1-9 OBS. CLOSE J1-10 24 VAC-COMMON A1 (OR) RADIO COMMAND (BK) L/S B L/S A J1 PLUG J1-1 (RD) (GN) "A" LIMIT CONTACTOR A (GN) (BL) 4 6 7 (Y/BK) (Y/BK) STOP (PU) (WH) (P/W) (Y/BK) (Y/BK) (GN) RESET (WH) TB 1 1 2 RADIO SHADOW 3 VDC COM 4 CLOSE 5 STOP/COM (BRN) 6 SOFT OPEN (OR) (OR) 7 HARD OPEN (GN) (GN) 8 INTERRUPT (SAFETY) (GY) (GY) 9 OPEN (OR/BK) (OR/BK) 10 CLOSE J1-11 (WH) 11 DC-GND J1-12 (RD) 12 LOCK 1 J1-13 (BK) (BK) 13 LOCK 1 J1-14 (BK) 14 ALARM 1 (BK) (BL) J1-15 (BL) ALARM 1 J1-16 (RD) (YE) 16 J4 PLUG 1 2 (GY) 17 (WH) (BRN) 18 (GY) 19 (BRN) 20 DUAL GATE INTERNAL MOTOR WIRING 1 - BLUE 2 - WHITE 3 - ORANGE 4 - YELLOW 5 - BLACK 8 - RED O/L - BROWN (YE) J2-3 J2-4 J2-5 J2-6 J2-7 J2-1 (Y/BK) 24VAC-IN 24VAC-COMMON SOFT OPEN NC "B" LIMIT CONTACTOR B (GN) (WH) (BRN) + SAFETY ALARM (SEE NOTE 5) (BL) (YE) TO REVERSE MOTOR DIRECTION INTERCHANGE PURPLE & GRAY WIRES ON MODEL SL585 OR THE RED & GREEN WIRES ON MODEL SL595 (YE) CD (YE) (YE) AB RADIO BLOCK FACTORY INSTALLED RADIO (GN) (YE) (YE) (RD) (RD) GROUND MASTER / SECOND MAGLOCK 15 (RD) = TERMINAL BLOCK IN LIMIT SWITCH ENCLOSURE (SL595 ONLY). EDGE/PHOTOEYE (SAFETY) 24 VAC INTERRUPT LOOP (SAFETY) EXIT LOOP NOTES: 1) Transformer primary voltage same as operator line voltage 24V secondary 60VA. 2) Wire color: 115V black, 208V red, 230V orange. 3) Single phase units are equipped with an external line break device and may be equipped with an additional internal pilot duty thermal o/l device. 4) Outlet wiring: Black wire to brass screw, white wire to silver screw and green wire to green screw. 5) When using a remote control or Single Button Control Station in lieu of the Soft Open feature, perform the following modifications to the operator: 1. Remove the green wire from R4 of the radio block and mount the wire to terminal block TB1 position 6. 2. Move the brown wire on Terminal Block TB1 position 6 (from radio block R4) to Terminal Block TB1 position 1. 40-32352F THREE PHASE SCHEMATIC ON/OFF SWITCH (BK) L2 3 PHASE POWER IN 230V CONNECTION (SEE NOTE 3) OVERLOAD L1 (BK) (BK) (BK) 4 B 3 5 A 6 4 A 3 1 B 2 (GY) (SL595 GN) (BK) (PU) (SL595 RD) (BK) (YE) (SL595 WH) L3 (BK) (BK) (BK) GROUND SEE NOTE 3 BLACK (SL595 ORANGE) (GN) PRIMARY WARNING (SEE NOTE 2) 24VAC R1 R2 RADIO SIGNAL R3 R4 5 3 9 6 460V CONNECTION (GY) (SL595 GN) (BK) (PU) (SL595 RD) (BK) (BK) 1 7 4 2 8 5 3 9 6 1 (GY) (SL595 GN) (BK) (PU) (SL595 RD) (YE) 2 (BK) CD 3 (YE) (SL595 WH) (YE) (YE) (RD) (RD) (YE) (YE) (BL) (BL) (BK) (BK) (SEE NOTE 4) (WH ) (BL) (RD) (Y/BK) (BK) (BRN) (BRN) (BK) (RD) (GY) (GN) J2-3 J2-4 J2-5 J2-6 J2-7 J2-1 "A" LIMIT CONTACTOR A J2-8 J2-2 (OR) 1 RPM - IN RPM - SUPPLY RPM GND J2-9 J2-10 J2-11 (WH) (BL) (WH ) (YE) (GN) (RD) 3 (BK) L/S B (PU) 2 (BRN) 575V BRAKE SOLENOID A1 NC COM (OR) (RD) B (GY) A2 A1 A (Y/BK) CLOSE J1-4 (GN) STOP J1-5 (Y/BK) SOFT OPEN J1-6 (BRN) HARD OPEN J1-7 INT. LOOP J1-8 (GN) J1-3 (OR) +24VDC 10 PIN - 1,2,3,5 CAPPED 10 4 6 7 8 9 INTERRUPT (SAFETY) LOOP HARNESS 10 PIN - 1,2,3,5 CAPPED 10 CLOSE OPEN (PU) (PU/WH) 8 9 A2 FIELD CONNECTIONS (Y/BK) J1-2 FREE EXIT LOOP HARNESS RPM SENSOR (BK) SHADOW 4 6 7 (YE) NC COM (Y/BK) (PU) L/S A (Y/BK) (Y/BK) STOP (PU) (WH) (P/W) (Y/BK) (Y/BK) (GN) RESET (WH) TB1 1 2 RADIO SHADOW 3 VDC COM 4 CLOSE 5 STOP/COM (BRN) 6 SOFT OPEN (OR) (OR) 7 HARD OPEN (GN) (GN) 8 INTERRUPT (SAFETY) OBS. OPEN J1-9 (GY) (GY) 9 OPEN OBS. CLOSE J1-10 (OR/BK) (OR/BK) 10 CLOSE J1-11 (WH) 11 DC-GND J1-12 (RD) 12 LOCK 1 J1-13 (BK) (BK) 13 LOCK 1 J1-14 (BK) (BK) (BL) 14 ALARM 1 J1-15 (BL) ALARM 1 J1-16 (RD) (YE) 16 J4 PLUG 1 2 (GY) 17 (WH) (BRN) 18 (GY) 19 (BRN) 20 DUAL GATE 230V BRAKE SOLENOID 575V CONNECTION (GN) 24VAC-IN 24VAC-COMMON SOFT OPEN NC "B" LIMIT CONTACTOR B 24 VAC-COMMON 230V BRAKE SOLENOID (SEE NOTE 3) GL CONTROL BOARD J2 PLUG RADIO COMMAND 5 4 8 (SEE NOTE 3) (YE) J1 PLUG J1-1 6 7 2 (YE) (SL595 WH) (BL) + (100 db) 1 (WH) 24V Sec. (SEE NOTE 1) FUSE 3.2A (BL) (TB 2) AB SAFETY ALARM A B (BL) RADIO BLOCK FACTORY INSTALLED RADIO To protect against fire and electrocution: • DISCONNECT power BEFORE installing or servicing operator. • Replace ONLY with fuse of same type and rating. Fuse: 3AG, 3.2A, 120V, SLO-BLO 2 1 MASTER / SECOND MAGLOCK 15 (RD) = TERMINAL BLOCK IN LIMIT SWITCH ENCLOSURE (SL595 ONLY). EDGE/PHOTOEYE (SAFETY) 24 VAC INTERRUPT LOOP (SAFETY) EXIT LOOP NOTES: 1) Transformer primary voltage is the same as the operator line voltage. Secondary 24V 60VA. 2) Wire color: 208V red, 230V orange, 460V purple, 575V gray. 3) Three phase units are equipped with an internal pilot duty thermal overload device or an external line monitoring device. 4) When using a remote control or Single Button Control Station in lieu of the Soft Open feature, perform the following modifications to the operator: 1. Remove the green wire from R4 of the radio block and mount the wire to terminal block TB1 position 6. 2. Move the brown wire on Terminal Block TB1 position 6 (from radio block R4) to Terminal Block TB1 position 1. 40-32351G 01-32632C © 2009, The Chamberlain Group, Inc. All Rights Reserved