758-1001 (8x0.51/2.3Dz – 75  + 3x1.5
mm2) PVC-Special
758-1001/2 (8x0.51/2.3Dz – 75  + 3x1.5 mm2) PUR-Special
Studio Connecting Cable
Application
Studio connecting cables are primary used in closed circuit TV systems and for compact installations in studios and
broadcasting vans.
Standards
Flame resistance
Construction
Element 1: Coax 0.51/2.3Dz (8x)
copper wire, bare, diameter 0.51 mm
Inner conductor
Insulation
Foam-PE, diameter 2.3 mm
Outer conductor
copper braid, tinned, diameter 2.8 mm
Screen
copper braid, tinned, diameter 3.2 mm
Sheath
PVC, diameter 3.7 mm
orange, black, green, blue, violet, grey, white, red
Element 2: Screened power cable 3x1.5 mm2
stranded copper wires, bare, diameter 1.6 mm
Inner conductor
Insulation
PVC, diameter 3.0 mm
Identification
1 x brown, 1x blue, 1 x yellow-green
Twisting
3 cores, diameter 6.4 mm
Insulation
2 x plastic foil, diameter 6.5 mm
Screen
copper braid, bare, diameter 7.1 mm
Insulation
1 x plastic foil, diameter 7.2 mm
Cable lay up
Elements
Stranding
8x coax 0.51/2.3Dz acc. to A. + 1 x screened power cable acc. to B
Core: 1 x screened power cable acc. to B
layer: 8 x coax acc. to A
(1+8), diameter 14.6 mm
LINKING THE FUTURE
www.prysmiangroup.com
st5ae
Version 1.0 | 15.04.2010
Page 1 of 4
758-1001 (8x0.51/2.3Dz – 75  + 3x1.5
mm2) PVC-Special
758-1001/2 (8x0.51/2.3Dz – 75  + 3x1.5 mm2) PUR-Special
Wrapping
Sheath
Printing
1 x PETP-web (0.03 mm), diameter 14.80 mm
PVC-special, altern. PU-special, wall thickness 1.2 mm, diameter 17.2 mm ± 0.4 mm
matt black, RAL 9005
DRAKA 758-1001 (8X0.51/2.3DZ-75  + 3x1.5 QMM) + batch no.
for PVC-special
DRAKA 758-1001/2 (8X0.51/2.3DZ-75  + 3x1.5 QMM) + batch no. for PUR-special
LINKING THE FUTURE
www.prysmiangroup.com
st5ae
Version 1.0 | 15.04.2010
Page 2 of 4
758-1001 (8x0.51/2.3Dz – 75  + 3x1.5
mm2) PVC-Special
758-1001/2 (8x0.51/2.3Dz – 75  + 3x1.5 mm2) PUR-Special
Mechanical properties
Minimum bending radius
Temperature range
without load
10 x D ( D= outer diameter )
with load
15 x D ( D= outer diameter )
during operation
- 30° C to + 70° C
Electrical properties
at 20°C
Coaxial
DC resistance
 115 /km
Inner conductor
Insulation resistance
 10 G*km
Mutual capacitance
60 nF/km
Characteristic impedance
75  ± 3 
at 1 MHz
Transfer impedance
5 m/m
Screening factor
 75 dB
Power cable 3x1.5 mm
 12.5 /km
DC resistance
 200 M*km
Insulation resistance
Test voltage
50 Hz. 1min
500 V rms
Operating voltage
AC
250 V rms
DC resistance
braid
 11.5 Vrms /km
Recommendation:
Under voltage above 65 V the power cable screen has to be contacted to earth termination at the power source device.
Electrical data
Coaxial
at 20°C
Attenuation
(dB/100m)
Crosstalk
(dB/500m)
Return loss
(dB)
Frequency
(MHz)
Frequency
(MHz)
Frequency
(MHz)
1
1.5
0.3 – 2.3
60
1 – 300
≥ 22
300 – 800
≥ 18
5
3.6
2.3 – 20
1000
10
4.7
20 – 800
90
20
6.5
30
7.9
100
14.4
200
20.6
300
25.6
500
33.6
800
43.0
LINKING THE FUTURE
www.prysmiangroup.com
st5ae
Version 1.0 | 15.04.2010
Page 3 of 4
758-1001 (8x0.51/2.3Dz – 75  + 3x1.5
mm2) PVC-Special
758-1001/2 (8x0.51/2.3Dz – 75  + 3x1.5 mm2) PUR-Special
Technical data
Product
code
Type
Weight
Drum size
kg/km
Standard
delivery
length
m
Copper
content
KTG
Tensile
force
Storage
N
Minimum
bending radius
N
mm
1002280
CT2739000
758-1001
360
250/500
081/091
210.8
950
175
inside
1002281
CT2739001
<
758-1001/2
350
250/500
081/091
210.8
950
175
inside
Product Code Table
Product Description
Product Code
758-1001 (8x0.51/2.3Dz+3x1.5)
PG Reference Code
60014004
PG Part Number
60014004
© PRYSMIAN GROUP 2010, All Rights Reserved
All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: any
modification or alteration afterwards of product may give different result.
The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without
the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right to
amend this specification without prior notice. This specification is not contractually valid unless specifically authorised by Prysmian Group.
LINKING THE FUTURE
www.prysmiangroup.com
st5ae
Version 1.0 | 15.04.2010
Page 4 of 4