Magnetic-Ballasts A

advertisement
SECTION A
1850 Wilson Avenue, Toronto,
Ontario, Canada, M9M 1A1
Ph: 416-741-7336 Fax: 416-741-9104
MAGNETIC MAGNETIC AND
BALLASTS ELECTRONIC
BALLASTS
A1
Etlin-Daniels reserves the right to discontinue, modify designs and change specifications without incurring obligation. While every
effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in
respect thereof and the company shall not be liable for any error herein.
Copyright © 2003 Etlin-Daniels
A2
A3
A4-A6
A7
A8
A9
A10-A13
A14
A15
A16
A17-A21
A22
A23
A24-A25
A26-A27
MAGNETIC AND ELECTRONIC BALLASTS
Magnetic and Electronic Ballasts
Etlin-Daniels Product Overview
K-TRONIK Ballasts
Magnetic Ballasts for:
Double Ended Lamps
Compact Fluorescent Lamps
Circline Fluorescent Lamps
Outside North America
Electronic Ballasts for:
Double Ended Lamps
Double Ended Lamps - Universal Voltage
Compact Fluorescent Lamps
2D and Circline Lamps
Multiple Voltage / Multiple Lamp
Power Factor Correction Capacitors
Suffix Code and Case Styles
Wire Lead Length
Glossary
Product
Overview
Magnetic Ballasts
A2
ETLIN-DANIELS
PRODUCT OVERVIEW
• Rapid Start Ballasts
These ballasts provide smooth starting to rapid start lamps – reaching
full brightness in about two seconds without the use of starters. They
have built-in filament windings that energize the low-voltage cathodes
in rapid start lamps. Because electrodes are continuously heated, less
voltage is required to strike an arc through a rapid start lamp than a
slimline one.
• Slimline Ballasts
Our slimline models are designed for use with single-pin slimline
lamps. They do not require the use of starters. These ballasts deliver
a high starting voltage to the lamps, enabling an arc to strike through
the tube without preheating the lamp cathodes (which are specially
constructed to withstand the shock).
• Circline Ballasts
These products are available in 430mA rapid start and preheat types,
designed for use with circline and conventional lamps. All circline
socket wires are fully sleeved.
• Trigger-Start Ballasts
These ballasts are designed for use with general fluorescent lamps
and do not require the use of starters. They contain preheat windings
which allow regular lamp filaments to be heated in one second.
However, they require a higher open-circuit voltage than rapid start
ballasts.
• Preheat Ballasts
These units are designed for use with general fluorescent lamps and
require the use of starters. These ballasts deliver an open-circuit
voltage high enough to activate the starter to preheat lamp filaments to
a temperature approximately 1750ºF. After a few seconds the starter
opens the filament circuit. This provides an additional power surge to
enable an electrical arc to strike through the lamp and ignite it. Lamp
current is then limited by the ballast to an operating level proper for the
lamp.
• Export (50/60Hz) Ballasts
Our export product offering consists of a variety of one and two-lamp
models for rapid start, preheat, high output, slimline, and 1500mA
lamps. Included in this product line are ballasts for 50 and 60Hz
applications, including 110, 120, 127, 220, 230, 240, and 277 volts.
Many of these models are available with resetting thermal applications.
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
K-Tronik
K-TRONIK BALLASTS
K-TRONIK BALLASTS
Complete line of Linear and Compact Fluorescent Ballasts
A3
We offer the complete line of K-TRONIK leading edge electronic ballasts.
Electronic Ballasts
•
•
•
•
Microprocessor based with intelligent software
Low inrush currents to extend lamp life
Universal voltage from 120V to 305V
Small case size for greater fixture design and
flexability
• ELP - end of life protection
• 5 Year warrantee from date of manufacture
K-TRONIK invests heavily in leading edge R&D and
quality manufacturing to bring you the most reliable
ballast products in the marketplace today.
K-TRONIK offers an extensive line of ballasts for a
global marketplace. This includes:
• T5 High Output, High Effeciency and Circular
• T8 Instant Start
• T8 Low and High light output
• Speciality Refrigeration (-30ºC) Ballasts
• Compact Fluorescent for twin, triple and quad lamps
• 347V ballasts for the Canadian marketplace
Linear Fluorescent Ballasts
Compact Fluorescent Ballasts
Etlin-Daniels carries a substantial inventory of K-TRONIK product as well as many other lighting components to
provide you with the right product at the right place and at the right price. We look forward to serving you and
earning your continued support. Please contact us for the most recent K-TRONIK catalog.
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Double Ended
Lamps
A4
MAGNETIC BALLASTS FOR
DOUBLE ENDED LAMPS
Double Ended Lamp - Less than 14W
WATTAGE
VOLTAGE POWER # OF
/ Hz
FACTOR BULBS
CAT. #
TECHNICAL SPECS
Magnetic Ballasts
CURRENT STARTING
APPROVALS
BF
THD%
UL
80
80
13
13
•
•
CASE WIRING
STYLE STYLE
cUL CSA
Wiring Style
1
S
LAMP TYPE F4T5
4W
120V/60Hz
LAMP TYPE F6T5
6W
120V/60Hz
LAMP TYPE F8T5
8W
120V/60Hz
NPF
1
NPF
CF-49-CC-TP *
CF-49-OC-TP * †
1
PH
PH
•
•
B1
A1
1
NPF
1
2
LAMP TYPE F14T12 (T8)
14W
120V60Hz NPF
CF-49-CC-TP *
CF-49-OC-TP * †
CF-68T5-PG-TP
0.12A
0.12A
0.12A
PH
PH
PH
80
80
80
15
15
15
•
•
•
•
•
•
B1
A1
E2
1
1
9
CF-49-CC-TP *
CF-49-OC-TP * †
CF-579-CC-TP *
CF-579-OC-TP * †
CF-79T-CC-TP
CF-1322T-CC-TP
CF-68T5-PG-TP
N-113-1-TP-IES
N-213-1-TP-IES
0.12A
0.12A
0.16A
0.16A
0.21A
0.3A
0.13A
0.12A
0.31A
PH
PH
PH
PH
PH
PH
PH
IES
IES
80
80
88
88
70
80
80
97
97
15
15
15
15
10
10
20
20
20
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
B1
A1
B1
A1
A4
B2
E2
J
J
1
1
1
1
2
2
9
19
20
N-113A-1-TP
N-113A-1-TP-SS
N-113-1-TP-IES
CF-13T5-PG-TP
N-213-1-TP-IES
0.28A
0.28A
0.16A
0.18A
0.3A
PH
PH
IES
PH
IES
84
84
79
80
80
15
15
30
30
30
•
•
•
•
•
•
•
•
•
•
C6
C6
J
E3
J
16
6
19
9
20
1
CF-1322-CC-TP *
CF-1322-OC-TP * †
CF-1322M-CC-TP *
CF-1322M-OC-TP * †
CF-1320S-CC-TP *
CF-1320S-OC-TP * †
CF-79T-CC-TP
CF-1322T-CC-TP
N-120-1-TP
0.33A
0.33A
0.33A
0.33A
0.33A
0.33A
0.21A
0.3A
0.69A
PH
PH
PH
PH
PH
PH
PH
PH
TS
80
80
80
80
80
80
70
80
93
15
15
15
15
15
15
10
10
10
•
•
•
•
•
•
•
•
•
B2
A2
B2
A2
B4
A4
A4
B2
D1
1
1
1
1
1
1
2
2
4
* Add -PF for single blow thermal fuse
† Replace -OC with -WC for with cord model
•
•
•
•
•
•
•
•
•
A1
A2
A4
B1
B2
B4
C1
C6
D1
E2
E3
J
2.00
2.50
2.00
2.25
2.50
2.50
6.00
6.00
6.00
--6.00
Lamp
Black
Ballast
Black
Line
2.36
3.11
2.36
2.75
3.15
3.00
6.61
6.61
6.46
1.61
1.54
6.61
1.10
1.85
1.18
1.50
1.14
1.50
2.36
1.89
1.89
1.97
2.00
1.89
Lamp
Black
Ballast
Black
Line
4
Lamp
Blue
Red
White
Ballast
Red
Black
For 40W & 30W lamp, use
disconnect lampholder.
Line
5
Lamp
Lamp
Yellow
Starting:
PH - Preheat
TS - Trigger Start
IES - Internal Electronic Starter
Yellow
DIMENSIONS IN INCHES
LENGTH
WIDTH HEIGHT
(W)
(H)
(M)
(L)
CASE
STYLE
1
1
2
NPF
2
LAMP TYPE F13T5
13W
120V/60Hz
0.12A
0.12A
Red
Ballast
Red
White
Blue
Black
Blue
Line
6
1.42
1.34
1.42
1.20
1.77
1.30
1.57
0.98
1.42
2.36
2.87
0.98
Lamp
Red
Ballast
Red
White
Blue
Black
Blue
Line
19
9
S
Lamp
White
Case Style
A
B
W
C
Lamp
W
W
White
Red
Red
H
H
Yellow
H
M
D
16
S
Lamp
E
J
H
H
Blue
Black
Line
20
L
L
W
Black
Black
M
M
L
Ballast
Ballast
M
L
White
L
White
Ballast
W
M
W
Lamp
Lamp
H
Red
L
Red
Yellow
Ballast
Yellow
Blue
Blue
Black
Blue
Black
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Double Ended
Lamps
MAGNETIC BALLASTS FOR
DOUBLE ENDED LAMPS
Double Ended Lamp - 15W to 32W
WATTAGE
VOLTAGE
/ Hz
POWER
FACTOR
# OF
BULBS
A5
CAT. #
TECHNICAL SPECS
CURRENT
STARTING
BF
APPROVALS
THD%
UL
CASE
STYLE
WIRING
STYLE
cUL CSA
Wiring Style
1
S
15W
120V/60Hz
NPF
1
2
CF-1322-CC-TP *
0.27A
PH
82
15
•
•
B2
1
CF-1322-OC-TP * †
0.27A
PH
82
15
•
•
A2
1
CF-1322M-CC-TP *
0.27A
PH
86
15
•
•
B2
1
CF-1322M-OC-TP * †
0.27A
PH
86
15
•
•
A2
1
CF-1320S-CC-TP *
0.27A
PH
82
20
•
•
B4
1
CF-1320S-OC-TP * †
0.27A
PH
82
20
•
•
A4
1
CF-79T-CC-TP
0.21A
PH
70
10
•
•
A4
1
CF-1322T-CC-TP
0.3A
PH
80
10
•
•
B2
1
CF-1540-1-TP-IES
0.32A
IES
93
30
•
•
C7
19
N-120-1-TP
0.63A
TS
70
10
•
•
D1
4
N-220-1-TP
0.65A
TS
50
20
•
•
C1
5
LAMP TYPE F17T8
Black
Ballast
Black
Line
4
Lamp
120V/60Hz
NPF
1
NPF
N-117-1-TP
1
0.41A
RS
70
20
•
•
C6
Ballast
4
CF-1322-CC-TP *
0.23A
PH
70
15
•
•
B2
1
CF-1322-OC-TP * †
0.23A
PH
70
15
•
•
A2
1
CF-1322M-CC-TP *
0.23A
PH
70
15
•
•
B2
1
CF-1322M-OC-TP * †
0.23A
PH
70
15
•
•
A2
1
CF-1320S-CC-TP *
0.23A
PH
70
15
•
•
B4
1
CF-1320S-OC-TP * †
0.23A
PH
70
15
•
•
A4
1
CF-1322T-CC-TP
0.3A
PH
80
10
•
•
B2
1
For 40W & 30W lamp, use
disconnect lampholder.
5
Lamp
Lamp
Yellow
NPF
1
0.24A
PH
65
15
•
•
B2
1
White
Blue
CF-1322-OC-TP * †
0.24A
PH
65
15
•
•
A2
1
Black
Blue
CF-1322M-CC-TP *
0.24A
PH
65
15
•
•
B2
1
CF-1322M-OC-TP * †
0.24A
PH
65
15
•
•
A2
1
CF-1320S-CC-TP *
0.24A
PH
65
15
•
•
B4
1
CF-1320S-OC-TP * †
0.24A
PH
65
15
•
•
A4
1
CF-1322T-CC-TP
0.3A
PH
80
10
•
•
B2
1
N-120-1-TP
0.63A
TS
80
10
•
•
D1
4
2
N-220-1-TP
0.59A
TS
54
20
•
•
C1
5
1
N-125-1-TP
0.54A
RS
80
20
•
•
D1
4
Line
6
Lamp
Red
NPF
LAMP TYPE F25T12
120V/60Hz
NPF
1
CF-25-WC-TP
0.31A
PH
70
20
•
•
G2
17
1
N-140A-1-TP
0.67A
PH
87
10
•
•
D1
16
N-140A-1-TP-SS
0.67A
PH
87
10
•
•
D1
6
N-140A-1-TP-WC
0.67A
PH
87
10
•
•
D1
17
LAMP TYPE F30T8. F30T12
120V/60Hz
NPF
CF-1540-1-TP-IES
0.33A
IES
83
25
•
•
C7
19
HPF
2
ES-240J-1-TP
0.66A
RS
77
20
•
•
C2
5
120V/60Hz
NPF
1
N-132-1-TP
0.60A
RS
90
20
•
•
D1
4
120V/60Hz
HPF
2
ES-232-1-TP
0.65A
RS
90
10
•
•
C2
5
ES-232-2-TP
0.28A
RS
90
10
•
•
C2
5
120V/60Hz
Blue
Black
Blue
16
S
Lamp
White
277V/60Hz
* Add -PF for single blow thermal fuse
† Replace -OC with -WC for with cord model
Starting:
PH - Preheat
RS - Rapid Start
IES - Internal Electronic Starter
Case Style
A
White
Line
LAMP TYPE F32T8
32W
Ballast
Red
120V/60Hz
Red
CF-1322-CC-TP *
LAMP TYPE F25T8
30W
Red
Ballast
Yellow
20W / 22W 120V/60Hz
25W
Red
Black
Line
LAMP TYPE F20T12
25W
Red
Blue
White
17W
120V/60Hz
LAMP TYPE F18T8
18W
Lamp
C
B
W
CASE
STYLE
H
H
M
M
M
L
L
L
D
G
W
H
H
L
Blue
17
Ballast
TS - Trigger Start
W
W
H
•
Ballast
Black
A2
A4
B2
B4
C1
C2
C6
C7
D1
G2
DIMENSIONS IN INCHES
LENGTH
WIDTH HEIGHT
(W)
(H)
(M)
(L)
2.50
3.11
1.85
1.34
2.00
2.36
1.18
1.42
2.50
3.15
1.14
1.77
2.50
3.00
1.50
1.30
6.00
6.61
2.36
1.57
9.00
9.49
2.40
1.61
6.00
6.61
1.89
0.98
2.50
2.48
1.89
1.34
6.00
6.46
1.89
1.42
-2.48
1.89
1.34
Lamp
19
Lamp
White
Red
Red
Yellow
Ballast
Black
M
W
L
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Magnetic Ballasts
LAMP TYPE F15T8, F15T12
Double Ended
Lamps
A6
MAGNETIC BALLASTS FOR
DOUBLE ENDED LAMPS
Double Ended Lamp - 40W and Larger
WATTAGE
VOLTAGE POWER # OF
/ Hz
FACTOR BULBS
CAT. #
TECHNICAL SPECS
Magnetic Ballasts
CURRENT STARTING
BF
APPROVALS
THD%
UL
CASE WIRING
STYLE STYLE
cUL CSA
Wiring Style
4
Lamp
LAMP TYPE F40T12
40W, 34W, 40W 120V/60Hz NPF
1
N-140-1-TP
CF-1540-1-TP-IES
N-140A-1-TP
N-140A-1-TP-SS
N-140A-1-TP-WC
N-240-1-TP ^ º
N-240-1-TP-IES
N-234-1-TP ^ º
ES-140-1-TP
ES-140N-1-TP
ES-240-1-TP
ES-240N-1-TP
LW-240-1-TP
ES-240J-1-TP
ES-140-2-TP
ES-140N-2-TP
ES-240-2-TP
ES-240N-2-TP
0.65A
0.35A
0.6A
0.6A
0.6A
0.64A
0.7A
0.8A
0.38A
0.44A
0.73A
0.77A
0.57A
0.77A
0.185A
0.17A
0.33A
0.3A
RS
IES
PH
PH
PH
RS
IES
RS
RS
RS
RS
RS
RS
RS
RS
RS
RS
RS
70
67
70
70
70
45
60
60
90
90
90
90
67
90
90
90
90
90
10
40
10
10
10
20
40
15
15
15
15
20
30
20
15
15
20
20
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
ES-275-1-TP *
ES-296-1-TP *
ES-296N-1-TP *
ES-196-1-TP
ES-196-2-TP
ES-296-2-TP
0.9A
1.2A
1.2A
0.73A
0.3A
0.51A
IS
IS
IS
IS
IS
IS
65
90
90
80
80
90
40
25
25
30
35
25
•
•
•
•
•
•
•
ES-275-1-TP *
ES-296-1-TP *
ES-296N-1-TP *
ES-196-1-TP
277V/60Hz
ES-196-2-TP
ES-296-2-TP
LAMP TYPE F72T12/HO, F96T12/HO, F96T12/HO/ES
95W, 110W
120V/60Hz HPF
2
ES-196HO-1-TP
ES-296HO-1-TP
277V/60Hz
ES-196HO-2-TP
ES-296HO-2-TP
1.1A
1.4A
1.2A
0.83A
0.36A
0.6A
IS
IS
IS
IS
IS
IS
75
90
90
75
80
74
30
25
25
30
40
40
•
•
•
•
•
•
•
1.2A
2.2A
0.58A
0.94A
RS
RS
RS
RS
95
95
98
95
40
10
40
10
•
•
•
•
•
•
•
•
40W
25W, 40W
25W, 34W. 40W
34W, 40W
2
120V/60Hz HPF
1
2
25W, 34W, 40W
34W, 40W
34W, 40W
277V/60Hz
1
2
LAMP TYPE F72T12
50W, 60W, 75W 120V/60Hz HPF
2
277V/60Hz
LAMP TYPE F96T12
50W, 60W, 75W 120V/60Hz HPF
2
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Starting:
RS - Rapid Start
PH - Preheat
IES - Internal Electronic Starter
^ Add -WS for standard bi-pin lampholders attached
º Add -LC for using 9” long can
* Remove -TP for model without thermal protector
D1
C7
D1
D1
G1
C1
D1
C1
C2
C2
C2
C2
C2
C2
C2
C2
C2
C2
4
19
16
6
17
5
20
5
6
6
5
5
5
5
6
6
5
5
D2
D2
D2
D4
D4
D2
8
8
8
25
25
15
D2
D2
D2
D4
D4
D2
8
8
8
8
15
15
D8
D8
D8
D8
6
5
6
5
Red
Blue
White
Ballast
Red
Black
For 40W & 30W lamp, use
disconnect lampholder.
Line
5
Lamp
Lamp
Yellow
Red
Ballast
Yellow
Red
White
Blue
Black
Blue
Line
6
Lamp
Red
Ballast
Red
White
Blue
Black
Blue
Line
8
Cutout Lampholder
Lamp
Black
Blue
Ballast
Line
White
Red
Lamp
Cutout Lampholder
15
Cutout Lampholder
Lamp
IS - Instant Start
Yellow
Blue
Yellow
19
Line
Ballast
Black
White
Red
Lamp
White
Lamp
Cutout Lampholder
Red
Red
Case Style
C
CASE
STYLE
W
H
M
L
D
C2
C7
D1
D2
D4
D8
G1
DIMENSIONS IN INCHES
LENGTH
WIDTH HEIGHT
(W)
(H)
(M)
(L)
9.00
9.49
2.40
1.61
2.50
2.48
1.89
1.34
6.00
6.46
1.89
1.42
11.0
11.65
3.15
1.85
9.00
9.45
3.15
1.85
11
11.7
3.15
2.5
6.00
6.46
1.89
1.42
G
W
Yellow
20
Lamp
Lamp
Lamp
White
White
Ballast
Black
Red
Red
Line
Blue
Yellow
Blue
Blue
Ballast
Yellow
Black
17
25
Ballast
Lamp
L
Blue
White
M
S
Black
H
H
16
Ballast
W
L
Ballast
Black
Lamp
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Compact
Fluorescent
MAGNETIC BALLASTS FOR
COMPACT FLUORESCENT LAMPS
A7
Compact Fluorescent Lamp
WATTAGE
VOLTAGE POWER
# OF
/ Hz
FACTOR BULBS
CAT. #
TECHNICAL SPECS
CURRENT STARTING
BF
APPROVALS
THD%
UL
cUL
CASE
STYLE
WIRING
STYLE
Wiring Style
CSA
Lamp
5W
120V/60Hz
NPF
1
CF-49-CC-TP †
0.13A
PH
80
15
•
•
B1
2
CF-49-OC-TP †
0.13A
PH
80
15
•
•
A1
2
CF-49-CC-TP †
0.13A
PH
77
15
•
•
B1
2
CF-49-OC-TP †
0.13A
PH
77
15
•
•
A1
2
CF-579-CC-TP †
0.15A
PH
87
15
•
•
B1
2
CF-579-OC-TP
0.15A
PH
87
15
•
•
A1
2
CF-79T-CC-TP
0.21A
PH
70
10
•
•
A4
2
CF-49-CC-TP †
0.13A
PH
77
15
•
•
B1
2
CF-49-OC-TP †
0.13A
PH
77
15
•
•
A1
2
CF-579-CC-TP †
0.15A
PH
100
20
•
•
B1
2
CF-579-OC-TP
0.15A
PH
100
20
•
•
A1
2
CF-1322-CC-TP †
0.30A
PH
93
15
•
•
B2
2
CF-1322-OC-TP
0.30A
PH
93
15
•
•
A2
2
CF-1322M-CC-TP †
0.26A
PH
93
15
•
•
B2
2
CF-1322M-OC-TP
0.26A
PH
93
15
•
•
A2
2
CF-1320S-CC-TP †
0.26A
PH
90
20
•
•
B4
2
CF-1320S-OC-TP
0.26A
PH
90
20
•
•
A4
2
CF-1322T-CC-TP
0.3A
PH
80
10
•
•
B2
2
CF-1322-WC-TP
0.26A
PH
90
15
•
•
G2
17
CF-1322T-WC-TP
0.3A
PH
80
10
•
•
E4
17
CF-1322-PG-TP
0.26A
PH
90
15
•
•
E1
17
CF-13-HP-TP
0.13A
PH
88
10
•
•
C3
3
CF-13S-HP-TP +
0.13A
PH
88
10
•
•
C7
3
CF-213S-HP-TP +
0.25A
PH
90
30
•
•
D3
18
NPF
CF-213-2-TP
0.22A
PH
90
30
•
•
D3
24
HPF
CF-213-2-HP-TP
0.12A
PH
90
30
•
•
D3
24
CF-118-1-TP
0.35A
PH
87
30
•
•
C6
3
CF-118-HP-TP
0.18A
PH
87
30
•
•
D1
3
2
CF-218-1-HP-TP+
0.42A
PH
87
15
•
•
C1
23
1
CF-118-2-OC-TP
0.24A
PH
90
30
•
•
A3
2
1
CF-126-1-TP
0.59A
PH
85
15
•
•
D1
3
LAMP TYPE CFL7W
7W
120V/60Hz
NPF
1
LAMP TYPE CFL9W
9W
120V/60Hz
NPF
1
Ballast
Black
Black
Line
3
Lamp
LAMP TYPE CFL13W
13W
120V/60Hz
White
NPF
1
HPF
2
277V/60Hz
Ballast
Blue
Black
Line
17
Ballast
Lamp
LAMP TYPE CFL18W
18W
120V/60Hz
NPF
1
HPF
277V/60Hz
18
Lamp
LAMP TYPE CFL26W
26W
120V/60Hz
Lamp
NPF
HPF
277V/60Hz
CF-126-1-HP-TP
0.28A
PH
89
30
•
•
D1
3
2
CF-226-1-HP-TP +
0.50A
PH
80
30
•
•
C1
23
1
CF-126-2-OC-TP
0.28A
PH
90
15
•
•
A3
2
White
120V/60Hz
120V/60Hz
NPF
1
HPF
CF-128-OC-TP
0.53A
PH
90
25
•
•
A3
2
CF-128-EN-TP
0.53A
PH
90
25
•
•
D3
2
CF-128-HP-TP
0.25A
PH
90
30
•
•
D3
3
+ Add -RJ for recessed downlight J-box mounting
† Replace -OC with -WC for with cord model
Case Style
A
C
B
W
W
DIMENSIONS IN INCHES
CASE
STYLE
M
M
L
L
L
D
E
W
G
H
H
H
L
M
W
L
Lamp
Lamp
H
M
23
Starting:
PH - Preheat
W
H
H
Red
Blue
Black
LAMP TYPE CFL28W / 15mm
28W
Ballast
Line
W
L
A1
A2
A3
A4
B1
B2
B4
C1
C6
C7
D1
D3
E1
E4
G2
LENGTH
(M)
2.00
2.50
2.80
2.00
2.25
2.50
2.50
6.00
6.00
2.50
6.00
4.33
----
(L)
2.36
3.11
3.27
2.36
2.75
3.15
3.00
6.61
6.61
2.48
6.46
4.76
1.89
1.94
2.48
WIDTH
(W)
HEIGHT
(H)
1.10
1.85
1.54
1.18
1.50
1.14
1.50
2.36
1.89
1.89
1.89
2.17
2.26
2.25
1.89
1.42
1.34
1.97
1.42
1.20
1.77
1.30
1.57
0.98
1.34
1.42
1.57
2.99
3.25
1.34
White
Ballast
Line
Blue
Black
24
Lamp
Lamp
Ballast
Line
Black
Black
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Magnetic Ballasts
2
LAMP TYPE CFL5W
Circline
Lamps
A8
MAGNETIC BALLASTS FOR
CIRCLINE FLUORESCENT LAMPS
Circline Fluorescent Lamp
Magnetic Ballasts
WATTAGE VOLTAGE POWER # OF
/ Hz
FACTOR BULBS
CAT. #
TECHNICAL SPECS
APPROVALS
CASE
STYLE
WIRING
STYLE
•
A2
7
•
B2
7
•
C7
10
•
•
C7
19
•
•
C7
10
10
•
•
D1
10
90
25
•
•
C7
10
IES
82
30
•
•
C7
19
IES
90
25
•
•
C7
10
0.58A
RS
64
15
•
•
D1
10
CF-1540-1-TP-IES
0.35A
IES
82
30
•
•
C7
19
N-140-1-WS-IES-TP
0.4A
IES
90
25
•
•
C7
10
N-140-1-WS -TP
0.52A
RS
58
15
•
•
D1
10
N-2232-1-WS-TP
0.6A
RS
62
15
•
•
C1
11
ES-3240-1-WS-TP
0.44A
RS
72
20
•
•
C1
11
N-3240-1-WS-TP
0.55A
RS
70
25
•
•
C1
11
ES-3240-1-WS-TP
0.56A
RS
72
25
•
•
C1
11
CURRENT
STARTING
BF
THD%
UL
CF-1322-OC-TP
0.30A
PH
73
15
•
CF-1322-CC-TP
0.30A
PH
73
15
•
CF-22-WS-TP
0.35A
PH
79
20
•
CF-1540-1-TP-IES
0.35A
IES
82
30
CF-22-WS-TP
0.29A
PH
79
15
N-122-1-WS-TP
0.49A
RS
72
N-122-1-WS-IES-TP
0.4A
IES
CF-1540-1-TP-IES
0.35A
N-132-1-WS-IES-TP
0.4A
N-140-1-WS-TP
7
LAMP TYPE FC6T9
20W
Wiring Style
cUL CSA
120V/60Hz NPF
1
Ballast
Black
Black
LAMP TYPE FC8T9
22W
120V/60Hz NPF
1
S
LAMP TYPE FC12T9
32W
120V/60Hz NPF
1
For positive starting, space 3 metal
clips 120° apart, as illustrated
10
LAMP TYPE FC16T9
40W
White
120V/60Hz NPF
1
Black
Line
White
Ballast
Red
Red
Blue
Blue
LAMP TYPE FC8T9 & FC12T9
22W & 32W 120V/60Hz NPF
2
HPF
For positive starting, space 3 metal
clips 120° apart, as illustrated
LAMP TYPE FC12T9 & FC16T9
32W & 40W 120V/60Hz NPF
2
HPF
Starting:
PH - Preheat
RS - Rapid Start
IES - Internal Electronic Starter
11
Line
Black
White
Ballast
Blue
Blue
Yellow
Yellow
Red
Red
Yellow
Yellow
For positive starting, space 3 metal
clips 120° apart, as illustrated.
Higher wattage lamp at right.
19
Black
Red
Ballast
Red
Yellow
White
Case Style
A
B
W
W
H
For positive starting, space 3 metal
clips 120° apart, as illustrated
H
M
M
L
L
C
D
W
A2
B2
C1
C7
D1
W
H
H
M
L
CASE
STYLE
DIMENSIONS IN INCHES
LENGTH
WIDTH HEIGHT
(W)
(H)
(M)
(L)
2.50
2.50
6.00
2.50
6.00
3.11
3.15
6.61
2.48
6.46
1.85
1.14
2.36
1.89
1.89
1.34
1.77
1.57
1.34
1.42
L
M
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Outside
North America
MAGNETIC BALLASTS FOR
OUTSIDE NORTH AMERICA
A9
Double Ended Lamps
WATTAGE
VOLTAGE
/ Hz
POWER # OF
FACTO BULBS
R
CAT. #
TECHNICAL SPECS
CURRENT STARTING
APPROVALS
BF
THD%
UL
CASE
STYLE
WIRING
STYLE
120V/60Hz
NPF
1
CF-20J-CC
0.24A
PH
65
15
•
•
B4
2
NPF
HPF
1
N-140J-1
ES-140-220-TP
0.61A
0.25A
PH
RS
64
90
10
15
•
•
•
K
C2
9
6
2
ES-240-220-TP
0.42A
RS
87
20
•
C2
5
ES-240-220/50-TP
0.41A
RS
79
20
•
C2
5
ES-240-240-TP
0.37A
RS
85
15
•
C2
5
ES-296-HO-220/50-TP
0.96A
RS
94
25
•
D8
5
Lamp
LAMP TYPE F40T12
40W
120V/60Hz
220V/
50/60Hz
240V/60Hz
Black
Ballast
Black
LAMP TYPE F72T12/HO
Line
85W, 95W 220V/
HPF
50/60Hz
LAMP TYPE F96T12/HO
85W, 95W, 220V/
HPF
110W
50/60Hz
Starting:
PH - Preheat
2
•
5
2
ES-296-HO-220/50-TP
1.0A
RS
90
15
•
•
D8
Lamp
5
Lamp
RS - Rapid Start
Yellow
Yellow
Red
Ballast
Red
White
Blue
Black
Blue
Line
6
Lamp
Red
Ballast
Red
White
Blue
Black
Blue
Line
9
S
Lamp
White
Ballast
Black
Blue
Black
Line
Case Style
B
W
C
W
H
H
M
M
L
L
D
B4
C2
D8
K
K
W
H
DIMENSIONS IN INCHES
CASE
STYLE
LENGTH
(M)
2.50
9.00
11
5.37
(L)
3.00
9.49
11.7
5.50
WIDTH HEIGHT
(W)
(H)
1.50
2.40
3.15
1.89
1.30
1.61
2.5
1.75
H
L
M
L
W
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Magnetic Ballasts
2
LAMP TYPE F20T12
20W
Wiring Style
cUL CSA
Double Ended
Lamps
A10
ELECTRONIC BALLASTS FOR
DOUBLE ENDED LAMPS
Double Ended Lamps - T5
Electronic Ballasts
WATTAGE VOLTAGE POWER # OF
/ Hz
FACTOR BULBS
CAT. #
TECHNICAL SPECS
CURRENT STARTING
BF
APPROVALS
THD%
UL
cUL
CASE
STYLE
WIRING
STYLE
CSA
Wiring Style
28
Red
Blue
Lamp
LAMP TYPE F8T5
8W
120V/
50/60Hz
Blue
NPF
1
2
EB-113-1-TP-MC
0.17A
RS
100
150
•
•
J
28
EB-113-1-TP-SL
0.17A
RS
100
150
•
•
N2
28
EB-113-1-TP-SL-MC
0.17A
RS
100
150
•
•
P2
28
EB-113-1-TP-SLL
0.17A
RS
100
150
•
•
N1
28
EB-113-1-TP-SLL-MC
0.17A
RS
100
150
•
•
P1
28
EB-208-1-TP
0.28A
RS
95
150
•
•
C6
30
EB-208-1-TP-MC
0.28A
RS
95
150
•
•
J
30
EB-208-1-TP-SL
0.28A
RS
95
150
•
•
N1
30
EB-208-1-TP-SL-MC
0.28A
RS
95
150
•
•
P1
30
Red
Black
30
120V/
50/60Hz
NPF
1
2
14W
EB-113-1-TP
0.25A
RS
95
150
•
•
C6
28
EB-113-1-TP-SL
0.25A
RS
95
150
•
•
N2
28
EB-113-1-TP-SL-MC
0.25A
RS
95
150
•
•
P2
28
EB-113-1-TP-SLL
0.25A
RS
95
150
•
•
N1
28
EB-113-1-TP-SLL-MC
0.25A
RS
95
150
•
•
P1
28
EB-113-1-TP-PN
0.25A
RS
95
150
•
•
S
28
EB-114-1-TP-FC
0.22A
RS
95
150
•
•
V
28
EB-213-1-TP
0.43A
RS
95
150
•
•
C6
30
EB-213-1-TP-MC
0.43A
RS
95
150
•
•
J
30
EB-213-1-TP-SL
0.43A
RS
95
150
•
•
N1
30
EB-213-1-TP-SL-MC
0.43A
RS
95
150
•
•
P1
30
120V/
NPF
50/60 Hz
120-277V/ HPF
50/60 Hz
LAMP TYPE F21T5HE
1
EB-114-1-TP-FC
0.23A
RS
95
150
•
•
V
28
2
EB-221HE-UV-TP-PIC
0.27A0.12A
RS
100
10
•
•
U
33
21W
120-277V/ HPF
50/60 Hz
LAMP TYPE F24T5HO
2
0.16A0.37A
RS
24W
NPF
1
EB-139HO-1-TP
0.41A
RS
100
130
•
•
N1
28
120-277V/ HPF
50/60 Hz
LAMP TYPE F28T5HE
2
EB-239HO-UV-TP-PIC
0.45A0.20A
RS
110
10
•
•
U
33
28W
120V/
NPF
50/60 Hz
120-277V/ HPF
50/60 Hz
LAMP TYPE F35T5HE
1
EB-135HE-1-TP
0.41A
RS
92
130
•
•
N1
28
2
EB-235HE-UV-TP-PIC
0.55A0.24A
RS
110
10
•
•
U
33
35W
120V/
NPF
50/60 Hz
120-277V/ HPF
50/60 Hz
LAMP TYPE F39T5HO
1
EB-135HE-1-TP
0.48A
RS
88
130
•
•
N1
28
2
EB-235HE-UV-TP-PIC
0.65A0.27A
RS
100
10
•
•
U
33
39W
Lamp
1
EB-139HO-1-TP
0.49A
RS
90
130
•
•
N1
28
2
EB-239HO-UV-TP-PIC
0.68A0.29A
RS
95
10
•
•
U
33
Starting:
IS - Instant Start
Black
White
R
R
B
B
Red
EB-221HE-UV-TP-PIC
95
10
•
•
U
R
R
B
B
Blue
Lamp
Blue
33
Yellow
Lamp
Yellow
Red
Red
Black
Ballast
R
R
Y
Y
B
B
33
Blue
Blue
P
Yellow
J
W
N
H
M
W
L
H
M
M
W
L
M
H
L
U
V
L
M
M
H
L
CASE
STYLE
C6
J
N1
N2
P1
P2
S
U
V
L
H
W
Yellow
S
RS - Rapid Start
W
M
Ballast
Red
White
Case Style
H
Blue
Lamp
120V/
NPF
50/60 Hz
120-277V/ HPF
50/60 Hz
C
Blue
Red
LAMP TYPE F14T5HE
120V/
50/60 Hz
R
R
B
B
Red
LAMP TYPE F13T5
13W
Ballast
White
H
M
DIMENSIONS IN INCHES
LENGTH
WIDTH HEIGHT
(W)
(H)
(M)
(L)
6.00
6.00
8.75
7.25
8.75
7.25
3.12
14.00
5.60
6.61
6.61
9.00
7.50
9.00
7.50
3.45
14.40
5.90
1.89
1.89
0.95
0.95
0.95
0.95
1.81
1.23
0.91
0.98
0.98
0.95
0.95
0.95
0.95
1.21
1.03
0.76
L
W
W
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Double Ended
Lamps
ELECTRONIC BALLASTS FOR
DOUBLE ENDED LAMPS
A11
Double Ended Lamps - F15T8 to F17T8
WATTAGE VOLTAGE POWER # OF
/ Hz
FACTOR BULBS
CAT. #
TECHNICAL SPECS
BF
APPROVALS
THD%
UL
cUL
CASE
STYLE
WIRING
STYLE
CSA
Wiring Style
5
Lamp
LAMP TYPE F15T8
15W
120V/
50/60Hz
Lamp
NPF
1
2
EB-126-1-TP
0.27A
RS
100
150
•
•
S
28
EB-126-1-TP-LC
0.27A
RS
100
150
•
EB-232RIS-1-TP
0.25A
IS
90
160
•
•
•
L2
28
L5
EB-232RIS-1-TP
0.38A
IS
80
160
•
31
Yellow
•
L5
12
Yellow
EB-2C72-1-TP
0.45A
RS
95
150
•
•
L1
30
LAMP TYPE F17T8
17W
120V/
50/60Hz
NPF
1
2
3
HPF
RS
150
150
•
•
S
28
0.31A
RS
100
150
•
•
L2
28
EB-132-1-TP-PIC
0.18A
IS
95
12
•
•
L3
31
EB-232RIS-1-TP
0.31A
IS
105
160
•
•
L5
31
EB-2C72-1-TP
0.60A
RS
95
12
•
•
L1
30
EB-232-1-TP-PIC
0.33A
IS
95
10
•
•
L3
12
EB-232RIS-1-TP
0.44A
IS
87
150
•
•
L5
12
EB-432RIS-1-TP
0.74A
IS
84
150
•
•
L5
13
Blue
Black
Blue
Line
12
Lamp
Lamp
Red
Yellow
Line
Black
Ballast
EB-432RIS-1-TP
0.86A
IS
82
140
•
•
L5
14
EB-132-1-TP-HP
0.18A
IS
95
12
•
•
L3
25
2
EB-232-1-TP
0.60A
IS
95
23
•
•
C4
12
EB-232-1-TP-HP
0.33A
IS
95
10
•
•
L3
12
EB-232SL-1-TP
0.34A
IS
95
25
•
•
D7
12
EB-232R-1-TP
0.39A
RS
100
20
•
•
D7
5
EB-332-1-TP
0.5A
IS
95
30
•
•
C4
13
EB-332-1-TP-HP
0.48A
IS
95
10
•
•
L3
13
EB-332-1-TP-PIC
0.48A
IS
95
10
•
•
L3
13
EB-432-1-TP
0.56A
IS
95
30
•
•
C4
14
EB-432-1-TP-HP
0.61A
IS
95
10
•
•
L3
14
EB-432-1-TP-PIC
0.61A
IS
95
10
•
•
L3
14
EB-232-2-TP
0.27A
IS
96
22
•
•
C4
12
EB-232SL-2-TP
0.16A
IS
96
25
•
•
D7
12
EB-232R-2-TP
0.16A
RS
100
20
•
•
D7
5
3
EB-332-2-TP
0.21A
IS
95
20
•
•
C4
13
4
EB-432-2-TP
0.26A
IS
97
30
•
•
C4
14
2
EB-232-3-TP
0.21A
RS
95
23
•
•
C4
12
EB-232SL-3-TP
0.12A
IS
95
30
•
•
D7
12
Lamp
EB-232R-3-TP
0.14A
RS
96
20
•
•
D7
5
Lamp
2
347V/
50/60Hz
0.31A
EB-126-1-TP-LC
Red
White
1
4
277V/
50/60Hz
EB-126-1-TP
Red
Ballast
4
3
Starting:
IS - Instant Start
Electronic Ballasts
CURRENT STARTING
Red
White
13
Lamp
Lamp
Lamp
Yellow
Line
Black
Red
Red
Red
Ballast
White
14
Lamp
Lamp
RS - Rapid Start
Yellow
Yellow
Line
Black
Ballast
Red
Red
Blue
Blue
White
25
Lamp
Case Style
C
Ballast
W
Black
H
H
CASE
STYLE
L
M
L
L
M
S
W
H
M
W
Blue
White
D
W
H
L
C4
D7
L1
L2
L3
L5
S
DIMENSIONS IN INCHES
LENGTH
WIDTH HEIGHT
(W)
(H)
(M)
(L)
9.00
9.00
6.00
6.00
8.90
8.90
3.12
9.49
9.49
6.46
6.46
9.45
9.50
3.45
2.28
1.65
1.89
1.89
1.80
1.70
1.81
1.57
1.15
1.00
1.15
1.37
1.15
1.21
28
Red
Blue
Red
Black
White
L
Blue
Lamp
Ballast
R
R
B
B
M
30 - SEE NEXT PAGE
31 - SEE NEXT PAGE
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Double Ended
Lamps
A12
ELECTRONIC BALLASTS FOR
DOUBLE ENDED LAMPS
Double Ended Lamps - F25T8
Electronic Ballasts
WATTAGE VOLTAGE POWER
# OF
/ Hz
FACTOR BULBS
CAT. #
TECHNICAL SPECS
CURRENT STARTING
BF
APPROVALS
THD%
UL
cUL
CASE
STYLE
WIRING
STYLE
5
LAMP TYPE F25T8
25W
120V/
50/60Hz
Wiring Style
CSA
NPF
1
EB-126-1-TP
0.41A
RS
95
130
•
EB-126-1-TP-LC
0.41A
RS
95
130
•
EB-232RIS-1-TP
0.39A
IS
97
150
•
•
EB-2C72-1-TP
0.72A
IS
95
150
•
EB-232RIS-1-TP
0.57A
IS
81
130
•
3
EB-432RIS-1-TP
0.95A
IS
85
130
4
EB-432RIS-1-TP
1.11A
IS
80
S
28
•
L2
28
L5
31
•
L1
30
Yellow
•
L5
12
Yellow
•
•
L5
13
White
Blue
130
•
•
L5
14
Black
1
EB-132-1-TP-HP
0.25A
IS
Blue
100
10
•
•
L3
31
EB-132-1-TP-PIC
0.25A
EB-232-1-TP
0.6A
IS
100
10
•
•
L3
31
IS
92
15
•
•
C4
EB-232-1-TP-HP
12
0.46A
IS
100
10
•
•
L3
12
EB-232-1-TP-PIC
0.46A
IS
100
10
•
•
L3
12
Lamp
EB-232SL-1-TP
0.43A
IS
92
20
•
•
D7
12
Lamp
EB-232R-1-TP
0.48A
RS
95
20
•
•
D7
5
EB-332-1-TP
0.84A
IS
92
20
•
•
C4
13
EB-332-1-TP-HP
0.67A
IS
100
10
•
•
L3
13
EB-332-1-TP-PIC
0.67A
IS
100
10
•
•
L3
13
EB-432-1-TP
0.73A
IS
81
20
•
•
C4
14
EB-432-1-TP-HP
0.89A
IS
100
10
•
•
L3
14
EB-432-1-TP-PIC
0.89A
IS
100
10
•
•
L3
14
EB-232-2-TP
0.27A
IS
92
15
•
•
C4
12
EB-232SL-2-TP
0.19A
IS
92
20
•
•
D7
12
EB-232R-2-TP
0.21A
RS
95
20
•
•
D7
5
Lamp
3
EB-332-2-TP
0.27A
IS
92
25
•
•
C4
13
Lamp
4
EB-432-2-TP
0.32A
IS
85
20
•
•
C4
14
2
EB-232-3-TP
0.21A
IS
90
17
•
•
C4
12
EB-232SL-3-TP
0.15A
IS
90
20
•
•
D7
12
EB-232R-3-TP
0.18A
RS
93
20
•
•
D7
5
2
HPF
2
3
4
277V/
50/60Hz
2
347V/
50/60Hz
Lamp
•
Lamp
Red
Ballast
Red
Line
12
Red
Yellow
Line
Ballast
Black
Red
White
13
Lamp
Yellow
Line
Red
Red
Red
Ballast
Black
White
Starting:
IS - Instant Start
RS - Rapid Start
14
Lamp
Lamp
Lamp
Lamp
Yellow
Yellow
Line
Black
Red
Red
Blue
Blue
Ballast
White
28
Red
Blue
Lamp
Blue
Red
Case Style
C
D
W
W
Black
H
H
L
M
CASE
STYLE
M
L
L
S
W
H
M
W
Ballast
White
H
L
L
M
C4
D7
L1
L2
L3
L5
S
DIMENSIONS IN INCHES
LENGTH
WIDTH HEIGHT
(W)
(H)
(M)
(L)
9.00
9.00
6.00
6.00
8.90
8.90
3.12
9.49
9.49
6.46
6.46
9.45
9.50
3.45
2.28
1.65
1.89
1.89
1.80
1.70
1.81
1.57
1.15
1.00
1.15
1.37
1.15
1.21
30
31
Black
White
Blue
Red
Lamp
Blue
Red
Lamp
Red
R
R
B
B
Blue
Black
White
R
R
B
B
Ballast
R
R
B
B
Ballast
Red
Red
Lamp
Blue
Blue
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Double Ended
Lamps
ELECTRONIC BALLASTS FOR
DOUBLE ENDED LAMPS
A13
Double Ended Lamps - F32T8 and up
WATTAGE VOLTAGE POWER
# OF
/ Hz
FACTOR BULBS
CAT. #
TECHNICAL SPECS
BF
APPROVALS
THD%
UL
cUL
CASE
STYLE
WIRING
STYLE
5
LAMP TYPE F32T8
32W
120V/
50/60Hz
NPF
1
HPF
0.51A
RS
95
130
•
•
S
28
EB-126-1-TP-LC
0.51A
RS
95
130
•
•
L2
28
EB-232RIS-1-TP
0.45A
IS
95
150
•
•
L5
31
EB-2C72-1-TP
0.89A
IS
90
130
•
•
L1
30
Yellow
EB-232RIS-1-TP
0.69A
IS
80
120
•
•
L5
12
Yellow
3
EB-432RIS-1-TP
1.15A
IS
87
130
•
•
L5
13
White
Blue
4
EB-432RIS-1-TP
1.35A
IS
80
120
•
•
L5
14
Black
Blue
1
EB-132-1-TP-HP
0.33A
IS
100
10
•
•
L3
31
EB-132-1-TP-PIC
0.33A
IS
100
10
•
•
L3
31
EB-232-1-TP
0.6A
IS
90
8
•
•
C4
12
EB-232-1-TP-HP
0.62A
IS
100
10
•
•
L3
12
EB-232-1-TP-PIC
0.62A
IS
100
10
•
•
L3
12
Lamp
EB-232SL-1-TP
0.51A
IS
90
15
•
•
D7
12
Lamp
EB-232R-1-TP
0.57A
RS
88
15
•
•
D7
5
EB-332-1-TP
0.75A
IS
88
20
•
•
C4
13
EB-332-1-TP-HP
0.92A
IS
100
10
•
•
L3
13
EB-332-1-TP-PIC
0.92A
IS
100
10
•
•
L3
13
EB-432-1-TP
0.9A
IS
82
20
•
•
C4
14
EB-432-1-TP-HP
1.18A
IS
100
10
•
•
L3
14
EB-432-1-TP-PIC
1.18A
IS
100
10
•
•
L3
14
EB-232-2-TP
0.27A
IS
90
8
•
•
C4
12
EB-232SL-2-TP
0.23A
IS
90
15
•
•
D7
12
EB-232R-2-TP
0.22A
RS
88
15
•
•
D7
5
Lamp
3
EB-332-2-TP
0.33A
IS
92
20
•
•
C4
13
Lamp
4
EB-432-2-TP
0.41A
IS
85
15
•
•
C4
14
2
EB-232-3-TP
0.21A
IS
90
10
•
•
C4
12
EB-232SL-3-TP
0.19A
IS
90
15
•
•
D7
12
EB-232R-3-TP
0.21A
RS
92
8
•
•
D7
5
EB-259-1
1.0A
IS
85
20
•
•
C4
12
EB-259-2
0.46A
IS
85
20
•
•
C4
12
2
3
4
277V/
50/60Hz
2
347V/
50/60Hz
Lamp
EB-126-1-TP
2
LAMP TYPE F96T8
59W
120V/
50/60Hz
277V/
50/50 Hz
Wiring Style
CSA
Electronic Ballasts
CURRENT STARTING
Lamp
Red
Ballast
Red
Line
12
Red
Yellow
Line
Ballast
Black
Red
White
13
Lamp
Yellow
Line
Red
Red
Red
Ballast
Black
White
HPF
1 or 2
14
Lamp
Lamp
Starting:
IS - Instant Start
Lamp
RS - Rapid Start
Lamp
Yellow
Yellow
Line
Black
Red
Red
Blue
Blue
Ballast
White
28
Red
Blue
Lamp
Blue
Red
Case Style
C
D
W
W
Black
L
M
CASE
STYLE
M
L
L
S
W
H
M
W
Ballast
White
H
H
H
L
L
M
C4
D7
L1
L2
L3
L5
S
DIMENSIONS IN INCHES
LENGTH
WIDTH HEIGHT
(W)
(H)
(M)
(L)
9.00
9.00
6.00
6.00
8.90
8.90
3.12
9.49
9.49
6.46
6.46
9.45
9.50
3.45
2.28
1.65
1.89
1.89
1.80
1.70
1.81
1.57
1.15
1.00
1.15
1.37
1.15
1.21
30
31
Black
White
Blue
Red
Lamp
Blue
Red
Lamp
Red
R
R
B
B
Blue
Black
White
R
R
B
B
Ballast
R
R
B
B
Ballast
Red
Red
Lamp
Blue
Blue
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Universal
Voltage
A14
UNIVERSAL VOLTAGE
ELECTRONIC BALLASTS
Double Ended Lamps - Universal Voltage
Electronic Ballasts
WATTAGE VOLTAGE POWER # OF
/ Hz
FACTOR BULBS
CAT. #
TECHNICAL SPECS
CURRENT STARTING
BF
APPROVALS
THD%
UL
cUL
CASE
STYLE
WIRING
STYLE
6
LAMP TYPE F17T8
17W
Wiring Style
CSA
120-277V
50/60Hz
HPF
1
EB-132-UV-TP-SL
Lamp
RS
100
12
•
•
L4
6
EB-132-UV-TP-PIC 0.08-0.18A
IS
100
10
•
•
L3
31
EB-232-UV-TP-SL
0.15-0.34A
RS
100
10
•
•
L4
32
EB-232-UV-TP-PIC 0.14-0.33A
IS
100
10
•
•
L3
12
Red
3
EB-332-UV-TP-PIC 0.21-0.48A
IS
100
10
•
•
L3
13
Red
4
EB-432-UV-TP-PIC 0.26-0.6A
IS
100
10
•
•
L3
14
White
Blue
Black
Blue
2
0.08-0.18A
LAMP TYPE F25T8
25W
120-277V
50/60Hz
HPF
1
EB-132-UV-TP-SL
Line
RS
100
10
•
•
L4
6
EB-132-UV-TP-PIC 0.11-0.26A
IS
100
10
•
•
L3
31
EB-232-UV-TP-SL
0.2-0.47A
RS
100
10
•
•
L4
32
EB-232-UV-TP-PIC 0.2-0.47A
IS
100
10
•
•
L3
12
3
EB-332-UV-TP-PIC 0.29-0.68A
IS
100
10
•
•
L3
13
Lamp
4
EB-432-UV-TP-PIC 0.38-0.88A
IS
100
10
•
•
L3
14
Lamp
1
EB-132-UV-TP-SL
2
0.1-0.24A
Ballast
12
LAMP TYPE F32T8
32W
120-277V
50/60Hz
HPF
2
Starting:
IS - Instant Start
0.13-0.3A
RS
100
10
•
•
L4
6
EB-132-UV-TP-PIC 0.14-0.31A
IS
100
10
•
•
L3
31
EB-232-UV-TP-SL
0.28-0.6A
RS
100
10
•
•
L4
32
EB-232-UV-TP-PIC 0.26-0.6A
IS
100
10
•
•
L3
12
3
EB-332-UV-TP-PIC 0.38-0.88A
IS
100
10
•
•
L3
13
4
EB-432-UV-TP-PIC 0.5-1.15A
IS
100
10
•
•
L3
14
Red
Yellow
Line
Ballast
Black
Red
White
13
Lamp
RS - Rapid Start
Lamp
Lamp
Yellow
Line
Red
Red
Red
Ballast
Black
White
14
Lamp
Lamp
Lamp
Lamp
Yellow
Yellow
Line
Red
Red
Blue
Blue
Ballast
Black
White
31
Lamp
Red
Blue
Ballast
Black
White
32
Case Style
Red
Blue
CASE
STYLE
H
M
W
L
L3
L4
9.45
9.45
1.80
1.15
Blue
Red
Lamp
Blue
DIMENSIONS IN INCHES
LENGTH
WIDTH HEIGHT
(W)
(H)
(M)
(L)
8.90
8.90
Blue
Lamp
Red
L
Red
B
B
R
R
1.37
1.26
Black
Ballast
R
R
B
B
White
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Compact
Fluorescent
ELECTRONIC BALLASTS FOR
COMPACT FLUORESCENT LAMPS
A15
Compact Fluorescent Lamps
WATTAGE
VOLTAGE
/ Hz
POWER # OF
FACTOR BULBS
CAT. #
TECHNICAL SPECS
CURRENT STARTING
BF
APPROVALS
THD%
UL
CASE WIRING
STYLE STYLE
Wiring Style
cUL CSA
13W
120V/ 50/60Hz NPF
1
120-277V
HPF
50/60Hz
120V/ 50/60Hz NPF
2
120V/ 50/60Hz NPF
120-277V
50/60Hz
HPF
2
120-277V
HPF
50/60Hz
LAMP TYPE CFL26W / CFQ26W / G24q
120V/ 50/60Hz NPF
120-277V
50/60Hz
150
•
•
C6
10
90
150
•
•
J
10
EB-113-1-TP-SL
0.22A
RS
90
150
•
•
N2
10
EB-113-1-TP-SL-MC
0.22A
RS
90
150
•
•
P2
10
EB-113-1-TP-SLL
0.22A
RS
90
150
•
•
N1
10
EB-113-1-TP-SLL-MC
0.22A
RS
90
150
•
•
P1
10
EB-113-1-TP-PN
0.22A
RS
90
150
•
•
S
10
0.06-0.135A
RS
100
10
•
•
T1
33*
EB-213-1-TP
0.43A
RS
95
150
•
•
C6
11
EB-213-1-TP-MC
0.43A
RS
95
150
•
•
J
11
EB-213-1-TP-SL
0.43A
RS
95
150
•
•
N1
11
EB-213-1-TP-SL-MC
0.43A
RS
95
150
•
•
P1
11
0.12-0.27A
RS
100
10
•
•
T1
33
0.33A
RS
100
150
•
•
S
10
EB-1C22-1-TP-LC
0.33A
RS
100
150
•
•
L1
10
EB-213-UV-TP-PIC
0.2-0.085A
RS
100
12
•
•
T1
33*
EB-218-UV-TP-PIC
0.08-0.18A
RS
100
10
•
•
T1
33*
0.59A
RS
95
150
•
•
C6
11
0.16-0.36A
RS
100
10
•
•
T1
33
EB-1C22-1-TP
EB-218-1-TP
2
HPF
EB-126-1-TP
0.40A
RS
90
15
•
•
S
10
EB-218-UV-TP-PIC
0.11-0.26A
RS
100
12
•
•
T1
33*
EB-226-UV-TP-PIC
0.11-0.25A
RS
100
10
•
•
T1
33*
0.8A
RS
95
15
•
•
C6
11
0.21-0.49A
RS
100
10
•
•
T1
33
EB-226-1-TP
EB-226-UV-TP-PIC
1
EB-1C22-1-TP
0.30A
IS
85
150
•
•
S
10
EB-1C22-1-TP-LC
0.30A
IS
85
150
•
•
L1
10
28W
EB-126-1-TP
0.4A
IS
90
130
•
•
S
10
38W
EB-1382D-1-TP
0.6A
IS
95
150
•
•
S
10
RS
RS
RS
110
95
95
10
10
10
•
•
•
•
•
•
T1
T2
T2
33*
33*
33
LAMP TYPE CFTR32W / GX24q
120-277V
50/60Hz
Lamp
11 - When using compact fluorescent
Black
Line
White
Blue
Blue
Yellow
Yellow
1
EB-226-UV-TP-PIC 0.35A-0.15A
EB-232T-UV-TP-PIC 0.28-0.12A
EB-232T-UV-TP-PIC 0.55A-0.24A
LAMP TYPE CFTR42W / GX24q
120-277V
50/60Hz
Ballast
Red
Red
Yellow
Yellow
Lamp
33
Lamp
Red
Black
Ballast
Red
R
R
Y
Y
B
B
Yellow
Yellow
Blue
Blue
Lamp
33* - When using single lamp
HPF
2
42W
Red
Red
Blue
Blue
Ballast
White
White
120V/ 50/60Hz NPF
32W
Black
Line
Lamp
1
120V/ 50/60Hz NPF
21W
90
RS
EB-218-UV-TP-PIC
HPF
120-277V
50/60Hz
LAMP TYPE GR10Q
RS
0.22A
EB-213-UV-TP-PIC
1
120V/ 50/60Hz NPF
26W
0.22A
EB-113-1-TP-MC
EB-213-UV-TP-PIC
120-277V
HPF
50/60Hz
LAMP TYPE CFL18W / CFQ18W / G24q
18W
EB-113-1-TP
ONE LAMP
Red
White
Red
Black
Ballast
Lamp
Green
HPF
1
2
EB-226-UV-TP-PIC
0.19A-0.45A
RS
110
10
•
•
T1
33*
EB-242T-UV-TP-PIC
0.37-0.16A
RS
100
10
•
•
T2
33*
RS
100
10
•
•
T2
33
EB-242T-UV-TP-PIC 0.74A-0.31A
Blue
Blue
Yellow (Cap off each yellow wire)
Starting:
RS - Rapid Start
Case Style
C
J
W
L
DIMENSIONS IN INCHES
CASE
STYLE
H
H
M
M
H
M
L
W
W
P
S
L
L
N
T
W
W
W
H
H
M
M
L
H
C6
J
L1
N1
N2
P1
P2
S
T1
T2
LENGTH
(M)
6.00
6.00
6.00
8.75
7.25
8.75
7.25
3.12
4.63
4.63
(L)
6.61
6.61
6.46
9.00
7.50
9.00
7.50
3.45
5.00
5.00
WIDTH HEIGHT
(W)
(H)
1.89
1.89
1.89
0.95
0.95
0.95
0.95
1.81
2.40
3.00
0.98
0.98
1.00
0.95
0.95
0.95
0.95
1.21
1.00
1.38
L
L
M
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Electronic Ballasts
10 - When using compact fluorescent
LAMP TYPE CFL13W / CFQ13W / G24q
Circline and
2D Lamps
A16
2D and Circline Lamps
WATTAGE
Electronic Ballasts
ELECTRONIC BALLASTS FOR
2D AND CIRCLINE BALLASTS
VOLTAGE
/ Hz
POWER # OF
FACTOR BULBS
CAT. #
TECHNICAL SPECS
CURRENT STARTING
APPROVALS
BF
THD%
UL
CASE WIRING
STYLE STYLE
cUL CSA
10
Black
LAMP TYPE FC8T9
22W
Wiring Style
120V/ 50/60Hz NPF
1
EB-1C22-1-TP-WS
0.33A
RS
90
150
•
•
S
10
EB-1C22-1-TP-WS-LC
0.33A
RS
90
150
•
•
L1
10
EB-1C3032-1-TP-WS
0.5A
RS
95
150
•
•
S
10
EB-1C3032-1-TP-WS-LC
0.5A
RS
95
150
•
•
L2
10
EB-1C3032-1-TP-WS
0.55A
RS
100
150
•
•
S
10
EB-1C3032-1-TP-WS-LC
0.55A
RS
100
150
•
•
L2
10
Line
Red
Red
Blue
Blue
Ballast
White
LAMP TYPE FCL-30
30W
120V/ 50/60Hz NPF
1
For positive starting, space 3 metal
clips 120° apart, as illustrated
LAMP TYPE FC12T9
32W
120V/ 50/60Hz NPF
1
LAMP TYPE FC8T9 + FC12T9
22 + 32W 120V/ 50/60Hz NPF
2
EB-2C72-1-TP-WS
0.6A
RS
76
150
•
•
L1
11
2
EB-2C72-1-TP-WS
0.75A
RS
70
150
•
•
L1
11
1
EB-1C22-1-TP
0.3A
RS
85
150
•
•
S
10
EB-1C22-1-TP-LC
0.3A
RS
85
150
•
•
L1
10
1
EB-126-1-TP
0.4A
RS
90
130
•
•
S
10
1
EB-1382D-1-TP
0.6A
RS
95
150
•
•
S
10
LAMP TYPE FC12T9 + FC16T9
32 + 40W 120V/ 50/60Hz NPF
LAMP TYPE CFS21W / GR10q
21W
120V/ 50/60Hz NPF
10 - When using 2D Lamps
Black
Line
White
LAMP TYPE CFS28W / GR10q
28W
120V/ 50/60Hz NPF
Red
Red
Blue
Blue
Ballast
LAMP TYPE CFS38W / GR10q
38W
120V/ 50/60Hz NPF
Starting:
RS - Rapid Start
Lamp
11
Line
Black
White
Ballast
Red
Red
Yellow
Yellow
Blue
Blue
Yellow
Yellow
For positive starting, space 3 metal
clips 120° apart, as illustrated.
Higher wattage lamp at right.
11 - When using 2D lamps
Black
Line
White
Blue
Blue
Yellow
Yellow
Lamp
Ballast
Red
Red
Yellow
Yellow
Lamp
Case Style
L
S
W
DIMENSIONS IN INCHES
CASE
STYLE
H
M
W
H
L
L
M
L1
L2
S
LENGTH
(M)
6.00
6.00
3.12
(L)
6.46
6.46
3.45
WIDTH HEIGHT
(W)
(H)
1.89
1.89
1.81
1.00
1.15
1.21
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
MultiBallasts
MULTIPLE VOLTAGE / MULTIPLE LAMP
ELECTRONIC BALLASTS
A17
Multi-Voltage Multi-Lamp Ballasts
WATTAGE
# OF
120 VOLT
230 VOLT
277 VOLT
347 VOLT
APPROVALS
BULBS CURRENT BF THD% CURRENT BF THD% CURRENT BF THD% CURRENT BF THD% UL cUL CSA
--
--
0.08A
85
15
•
•
6.5” 1.78” 1.25” 6.00”
--
--
0.12A
90
15
•
•
6.5” 1.78” 1.25” 6.00”
90
85
79
54
86
82
11
10
1
10
8
8
0.16A
0.2A
0.19A
0.19A
0.25A
0.25A
90
84
78
54
87
82
12
11
11
13
9
9
•
•
•
•
•
•
•
•
•
•
•
•
6.5” 2.87” 1.14” 5.94”
98
83
60
100
98
110
89
87
59
86
92
10
11
11
9
9
8
8
8
8
6
7
0.11A
0.1A
0.1A
0.13A
0.14A
0.18A
0.21A
0.18A
0.19A
0.24A
0.27A
98
84
60
110
98
100
88
87
58
85
94
16
18
16
11
9
9
8
9
8
8
8
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
6.5” 2.83” 1.14” 5.91”
110
97
98
89
17
13
12
11
-----
-----
-----
•
•
•
•
•
•
•
•
5.24” 2.48” 1.18” 4.84”
100
90
80
95
90
18
10
12
9
10
------
------
------
•
•
•
•
•
•
•
•
•
•
5.3” 2.45” 1.13” 4.81”
• All Multi-Voltage, Multi-Lamp Ballasts are all Rapid Start, High Power Factor ballasts
• Suffix “BM” - Bottom Mount with Studs (see page A23 for diagram)
• Suffix “S” - Cool Operator
Wiring Style
ONE LAMP
Red
White
Red
Black
Ballast
Lamp
Green
Blue
Blue
Case Dimentions
Yellow (Cap off each yellow wire)
TWO LAMP - Series
Lamp
Red
Black
Blue
Green
Lamp
Lamp
H
Red
Yellow
Ballast
Yellow
Blue
Red
White
Black
Yellow
Ballast
Green
TWO LAMP - Parallel
Red
White
M
Yellow
Blue
Blue
Lamp
L
W
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Electronic Ballasts
MODEL #: CSD-313P / CSD-313PBM -- Series
13W
2
-------MODEL #: CSD-318PBM -- Series
18W
2
-------MODEL #: CSD-B42P / CSD-B42PBM -- Parallel
26W
2
------0.19A
32W
------0.24A
36W
------0.23A
39W
------0.24A
40W
------0.31A
42W
------0.31A
MODEL #: CSD-B42PBMS -- Series
PLT 32W
1
------0.14A
PLL 36W
------0.21A
PLL 39W
------0.12A
PLL 40W
------0.16A
PLT 42W
------0.17A
PLT 26W
2
------0.22A
PLT 32W
------0.25A
PLL 36W
------0.23A
PLL 39W
------0.24A
PLL 40W
------0.3A
PLT 42W
------0.34A
MODEL #: CSD-UV18P -- Parallel
PLT 13W
1
0.14A
110
13
0.07A
110
11
0.06A
PLT 18W
0.16A
97
8
0.08A
97
11
0.07A
PLT 13W
2
0.24A
98
1
0.13A
98
10
0.11A
PLT 18W
0.32A
89
8
0.17A
89
10
0.14A
MODEL #: CSD-UV18PS -- Parallel, 90ºC Max Case Temp. / -30ºC Start Temp.
13W
1
0.13A
100
8
0.07A
100
12
0.05A
18W
0.15A
95
7
0.09A
95
7
0.07A
28W
0.20A
80
9
0.10A
80
9
0.08A
13W
2
0.25A
100
5
0.12A
95
6
0.10A
18W
0.32A
95
8
0.15A
90
8
0.13A
CASE DIMENTIONS
L
W
H
M
MultiBallasts
Electonic Ballasts
A18
WATTAGE
MULTIPLE VOLTAGE / MULTIPLE LAMP
ELECTRONIC BALLASTS
# OF
120 VOLT
230 VOLT
277 VOLT
347 VOLT
APPROVALS
BULBS CURRENT BF THD% CURRENT BF THD% CURRENT BF THD% CURRENT BF THD% UL cUL CSA
MODEL #: CSD-UV32P -- Parallel
PLT 26W
1
0.24A
92
26
0.13A
94
12
0.11A
PLT 32W
0.27A
85
19
0.15A
88
10
0.13A
PLT 42W
0.37A
90
4
0.21A
89
9
0.16A
PLT 26W
2
0.43A
89
3
0.23A
92
12
0.2A
PLT 32W
0.53A
82
4
0.28A
84
15
0.23A
MODEL #: CSD-UV32PS -- Parallel, 90ºC Max Case Temp. / -30ºC Starting Temp.
26W
1
0.24A
95
12
0.13A
95
13
0.10A
32W
0.27A
93
6
0.14A
93
11
0.12A
42W
0.35A
90
6
0.18A
90
11
0.15A
26W
2
0.44A
95
4
0.23A
95
7
0.18A
32W
0.53A
90
5
0.27A
90
7
0.22A
MODEL #: CSD-UV32PX -- Series
PLT 26W
1
0.29A
100
9
0.15A
100
7
0.13A
PLT 32W
0.29A
92
4
0.16A
93
8
0.13A
PLT 42W
0.37A
89
6
0.2A
87
7
0.17A
PLT 26W
2
0.49A
100
5
0.25A
100
9
0.21A
PLT 32W
0.56A
88
5
0.3A
88
9
0.25A
MODEL #: CSD-UV42P / CSD-UV42PBM -- Parallel
32W
1
0.27A
95
6
0.14A
95
13
0.12A
36W
0.27A
85
6
0.14A
85
14
0.12A
38W
0.28A
83
6
0.14A
85
14
0.70A
39W
0.30A
85
8
0.15A
98
13
0.12A
40W
0.38A
90
4
0.18A
90
10
0.18A
42W
0.35A
95
9
0.18A
95
3
0.18A
50W
0.33A
75
4
0.17A
75
4
0.15A
55W
0.38A
75
9
0.19A
76
13
0.16A
26W
2
0.46A
100
2
0.25A
100
9
0.19A
32W
0.52A
95
2
0.27A
95
8
0.22A
36W
0.57A
85
8
0.27A
85
8
0.23A
39W
0.59A
80
5
0.29A
80
9
0.23A
40W
0.71A
100
1
0.36A
90
6
0.30A
42W
0.74A
90
1
0.36A
90
1
0.31A
• All Multi-Voltage, Multi-Lamp Ballasts are all Rapid Start, High Power Factor ballasts
• Suffix “BM” - Bottom Mount with Studs (see page A23 for diagram)
• Suffix “S” - Cool Operator
CASE DIMENTIONS
L
W
H
M
94
88
87
92
83
32
17
9
9
8
------
------
------
•
•
•
•
•
•
•
•
•
•
6.5” 2.83” 1.14” 5.91”
95
93
90
95
90
14
11
12
8
7
------
------
------
•
•
•
•
•
•
•
•
•
•
6.5” 2.87” 1.13” 5.94”
100
94
88
100
89
9
9
7
8
9
------
------
------
•
•
•
•
•
•
•
•
•
•
5.24” 2.48” 1.18” 4.84”
95
85
85
85
90
95
75
76
100
95
88
80
100
90
20
23
18
24
6
15
15
13
10
9
9
10
7
7
---------------
---------------
---------------
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
6.49” 2.91” 1.14” 5.91”
Wiring Style
ONE LAMP
Red
White
Red
Black
Ballast
Lamp
Green
Blue
Blue
Case Dimensions
Yellow (Cap off each yellow wire)
TWO LAMP - Series
Lamp
Red
Black
Blue
Green
Lamp
Lamp
H
Red
Yellow
Ballast
Yellow
Blue
Red
White
Black
Yellow
Ballast
Green
TWO LAMP - Parallel
Red
White
M
Yellow
Blue
Blue
Lamp
L
W
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
MultiBallasts
MULTIPLE VOLTAGE / MULTIPLE LAMP
ELECTRONIC BALLASTS
WATTAGE
# OF
120 VOLT
230 VOLT
277 VOLT
347 VOLT
APPROVALS
BULBS CURRENT BF THD% CURRENT BF THD% CURRENT BF THD% CURRENT BF THD% UL cUL CSA
CASE DIMENTIONS
W
H
M
35
19
21
24
20
12
10
11
11
8
8
8
8
9
9
----------------
----------------
----------------
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
6.49”
2.91”
1.14”
5.91”
9.5
10
9
8
8
7
7.5
--------
--------
--------
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5.3”
2.45”
1.13”
4.81”
13
22
---
---
---
•
•
•
•
6.49”
2.91”
1.14”
5.91”
13
9
9
----
----
----
•
•
•
•
•
•
7.76”
3.15”
1.44”
7.24”
32
27
28
8
8
8
8
--------
--------
--------
•
•
•
•
•
•
•
•
•
•
•
•
•
•
12.80” 1.34”
1.14” 12.48”
Wiring Style
ONE LAMP
Red
White
Red
Black
Ballast
Lamp
Green
Blue
Blue
Case Dimensions
Yellow (Cap off each yellow wire)
TWO LAMP - Series
Lamp
Red
Black
Blue
Green
Lamp
Lamp
H
Red
Yellow
Ballast
Yellow
Blue
Red
White
Black
Yellow
Ballast
Green
TWO LAMP - Parallel
Red
White
M
Yellow
Blue
Blue
Lamp
A19
Electronic Ballasts
MODEL #: CSD-UV42PS -- Parallel, 90ºC Max Case Temp. / -30ºC Start Temp.
PLT 26W
1
0.25A
110
15
0.13A
110
12
0.12A
110
PLT 32W
0.29A
94
13
0.15A
94
10
0.13A
96
PLL 36W
0.29A
89
13
0.15A
90
11
0.13A
90
2D 38W
0.28A
62
16
0.14A
61
14
0.13A
62
PLL 39W
0.29A
63
12
0.15A
63
10
0.13A
63
PLL 40W
0.36A
93
8
0.19A
93
9
0.16A
93
PLT 42W
0.39A
93
6
0.2A
90
9
0.17A
93
PLL 50W
0.37A
79
7
0.2A
79
9
0.17A
78
PLL 55W
0.36A
69
8
0.2A
70
9
0.16A
70
PLT 26W
2
0.46A
100
4
0.46A
100
4
0.2A
100
PLT 32W
0.57A
92
2
0.29A
93
10
0.24A
92
PLT 36W
0.52A
86
2
0.27A
86
10
0.22A
86
PLL 39W
0.54A
61
2
0.28A
61
10
0.23A
62
PLL 40W
0.69A
91
2
0.36A
90
11
0.28A
90
PLT 42W
0.73A
90
2
0.37A
88
10
0.31A
87
MODEL #: CSS-UV42PS -- Parallel, 90ºC Max Case Temp. / -30ºC Start Temp.
26W
1
0.22A
100 4.5
0.11A
100 7.5
0.10A
100
32W
0.27A
100
7
0.14A
100
9
0.12A
100
36W
0.26A
95
7
0.14A
95
9
0.12A
95
39W
0.32A
85
6
0.15A
85
8
0.14A
85
40W
0.35A
95
7
0.17A
100
9
0.15A
95
42W
0.37A
95
7
0.18A
95
8
0.16A
95
26W
2
0.47A
100
8
0.23A
100
5
0.19A
100
MODEL #: CSD-UV57PS -- Series
PLT 57W
1
0.95A
84
6
0.49A
84
13
0.4A
84
2
0.48A
88
10
0.25A
91
18
0.22A
91
MODEL #: CSD-UV70PS -- Series
PLT 70W
1
0.62A
99
8
0.32A
94
10
0.27A
99
PLT 57W
2
0.99A
93
1
0.51A
93
9
0.43A
93
PLT 70W
1.2A
92
1
0.63A
91
8
0.52A
92
MODEL #: EPD-A54T5 -- Parallel
50W
1
0.46A
90
10
0.24A
92
9
0.21A
91
54W
0.48A
90
8
0.25A
88
8
0.22A
88
55W
0.45A
73
10
0.24A
72
9
0.21A
72
39W
2
0.72A
96
5
0.38A
98
9
0.32A
98
50W
0.90A
91
6
0.46A
91
9
0.39A
91
54W
0.963A
87
6
0.48A
90
8
0.40A
90
55W
0.93A
73
6
0.48A
75
9
0.40A
75
• All Multi-Voltage, Multi-Lamp Ballasts are all Rapid Start, High Power Factor ballasts
• Suffix “BM” - Bottom Mount with Studs (see page A23 for diagram)
• Suffix “S” - Cool Operator
L
L
W
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
MultiBallasts
Electronic Ballasts
A20
WATTAGE
MULTIPLE VOLTAGE / MULTIPLE LAMP
ELECTRONIC BALLASTS
# OF
120 VOLT
230 VOLT
277 VOLT
347 VOLT
APPROVALS
BULBS CURRENT BF THD% CURRENT BF THD% CURRENT BF THD% CURRENT BF THD% UL cUL CSA
MODEL #: ESD-A21T5 -- Series
14W
1
0.15A
97
10
0.08A
98
15
0.07A
99
21W
0.2A
95
6
0.11A
98
11
0.09A
97
14W
2
0.27A
90
6
0.15A
93
8
0.13A
93
21W
0.39A
90
4
0.21A
93
8
0.17A
93
MODEL #: ESD-A35T5 -- Series
28W
1
0.29A
107
6
0.16A
108
10
0.13A
107
35W
0.35A
102
5
0.19A
103
9
0.16A
103
28W
2
0.56A
93
5
0.3A
96
7
0.25A
96
35W
0.69A
90
4
0.36A
92
6
0.3A
95
MODEL #: ESD-A40T8 -- Series
32W
1
0.32A
99
5
0.18A
100
10
0.15A
100
40W
0.41A
89
4
0.22A
92
8
0.18A
92
25W
2
0.46A
88
4
0.25A
88
8
0.21A
89
32W
0.6A
93
4
0.33A
95
6
0.26A
95
40W
0.76A
85
4
0.42A
86
6
0.33A
86
MODEL #: ESD-A54T5 / ESD-A54T5S -- Series
39W
1
0.42A
117
14
0.38A
114
18
0.19A
111
50W
0.50A
102
12
0.27A
100
14
0.23A
101
54W
0.48A
89
12
0.26A
94
15
0.22A
96
55W
0.44A
89
16
0.23A
90
16
0.21A
89
39W
2
0.73A
106
5
0.38A
104
12
0.32A
102
50W
0.89A
92
5
0.48A
94
11
0.40A
95
54W
0.99A
92
5
0.52A
94
11
0.43A
96
55W
0.82A
81
6
0.43A
80
13
0.36A
80
MODEL #: ESD-B40T8 -- Series
32W
1
------0.15A
99
40W
------0.18A
91
25W
2
------0.21A
83
32W
------0.27A
91
40W
------0.33A
87
MODEL #: FSD-A18PBM / FSD-A18PS -- Series
FC9T5
1
0.18A
70
2
0.09A
71
11
0.08A
71
F17T8
0.28A
67
1
0.66A
70
10
0.13A
68
F25T8
0.2A
72
2
0.11A
73
10
0.09A
73
26PBX
0.19A
76
2
0.10A
76
10
0.07A
77
28T5
0.29A
100
6
0.16A
102
11
0.13A
102
35T5
0.36A
99
3
0.19A
101
12
0.16A
101
2D 16W
0.16A
80
3
0.08A
80
10
0.07A
80
2D 21W
0.15A
60
3
0.08A
60
10
0.07A
60
2D 28W
0.20A
55
1
0.11A
55
10
0.09A
55
2D 38W
0.21A
45
1
0.12A
45
10
0.09A
45
14WT5
0.15A
100
3
0.08A
182
19
0.07A
102
21WT5
0.23A
108
2
0.12A
103
9
0.07A
103
28WT5
0.39A
103
2
0.16A
102
11
0.13A
100
35WT5
0.37A
99
7
0.19A
100
11
0.16A
98
PLC 13W
0.15A
109
3
0.08A
109
11
0.07A
109
PLT 13W
0.15A
106
3
0.08A
106
11
0.07A
106
PLC 18W
0.17A
94
3
0.09A
94
11
0.08A
94
PLT 18W
0.17A
98
2
0.09A
94
10
0.08A
94
PLL 24W
0.17A
72
2
0.09A
72
10
0.08A
73
PLT 26W
0.19A
75
2
0.10A
76
101
0.09A
76
F17T9
2
0.21A
63
2
0.15A
63
11
0.13A
63
14WT5
0.3A
97
2
0.16A
97
10
0.13A
96
2D 16W
0.32A
77
1
0.17A
77
11
0.14A
77
PLC 13W
0.27A
95
2
0.14A
95
11
0.12A
96
PLT 13W
0.28A
98
1
0.15A
99
10
0.12A
98
PLC 18W
0.33A
88
2
0.17A
87
11
0.14A
87
PLL 18W
0.29A
54
1
0.15A
54
10
0.13A
54
PLT 18W
0.33A
85
2
0.17A
86
11
0.14A
85
• All Multi-Voltage, Multi-Lamp Ballasts are all Rapid Start, High Power Factor ballasts
• Suffix “BM” - Bottom Mount with Studs (see page A23 for diagram)
• Suffix “S” - Cool Operator
CASE DIMENTIONS
W
H
M
36
18
10
7
-----
-----
-----
•
•
•
•
•
•
•
•
11.5”
1.34”
1.02”
11.1”
15
12
8
7
-----
-----
-----
•
•
•
•
•
•
•
•
11.5”
1.34”
1.02”
11.1”
14
11
9
7
6
------
------
------
•
•
•
•
•
•
•
•
•
•
12.8”
1.34”
1.14” 12.48”
49
22
20
30
13
12
12
13
---------
---------
---------
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
12.8”
1.34”
1.14” 12.48”
8
6
7
8
9
0.13A
0.15A
0.17A
0.22A
0.27A
100
91
84
91
88
42
23
13
7
5
•
•
•
•
•
•
•
•
•
•
12.8”
1.34”
1.14” 12.48”
12
12
12
11
12
12
12
14
11
11
15
19
12
12
19
14
13
12
12
12
12
12
12
12
11
12
11
12
-----------------------------
-----------------------------
-----------------------------
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
6.5”
1.69”
1.00”
5.9”
Case Dimensions
TWO LAMP - Series
ONE LAMP
Red
White
Ballast
Blue
H
Yellow
Ballast
Green
Lamp
Red
Black
Lamp
Blue
Red
White
Red
Black
Green
L
M
Yellow
Blue
Blue
Lamp
L
W
Yellow (Cap off each yellow wire)
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
MultiBallasts
MULTIPLE VOLTAGE / MULTIPLE LAMP
ELECTRONIC BALLASTS
WATTAGE
# OF
120 VOLT
230 VOLT
277 VOLT
347 VOLT
APPROVALS
BULBS CURRENT BF THD% CURRENT BF THD% CURRENT BF THD% CURRENT BF THD% UL cUL CSA
CASE DIMENTIONS
W
H
M
104
105
86
78
80
57
66
87
85
78
63
91
88
93
95
-74
73
90
77
98
88
19
7
8
37
15
17
1
13
9
6
9
13
8
7
7
-7
6
6
7
6
8
-----------------------
-----------------------
-----------------------
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
6.5”
1.69”
1.00”
5.91”
110
96
80
7
11
8
12
9
9
7
9
12
8
8
8
6
10
8
7
7
7
8
6
7
7
6
6
6
0.13A
0.08A
0.12A
0.07A
0.10A
0.09A
0.13A
0.08A
0.08A
0.10A
0.13A
0.13A
0.13A
0.06A
0.11A
0.13A
0.18A
0.16A
0.13A
0.18A
0.16A
0.15A
0.19A
0.17A
0.21A
109
96
79
8
17
9
25
12
12
8
18
23
11
7
8
8
16
10
8
8
8
8
8
7
7
7
7
7
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
6.5”
1.69”
1.00”
5.91”
---------------------
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
4.09”
2.42”
1.18”
4.45”
82
55
71
93
90
88
93
75
68
96
88
83
95
93
71
88
84
81
94
88
80
55
71
98
91
88
93
74
68
96
89
83
95
92
71
89
86
82
95
88
73
12
--76
13
--77
16
--60
16
--58
12
--45
11
--100
15
--99
11
--104
10
--109
17
--96
14
--107
17
--96
14
--62
10
--74
10
--100
10
--110
11
--98
10
--101
11
--92
9
--• Suffix “S” - Cool Operator
A21
Electronic Ballasts
MODEL #: FSD-A32PBM / FSD-A32PS -- Series
F26DBX
1
------0.12A
F32T8
0.34A
103
3
0.18A
105
8
0.15A
FC12T5
0.34A
86
3
0.18A
86
7
0.15A
2D 21W
0.20A
76
8
0.11A
78
11
0.09A
2D 28W
0.28A
79
5
0.15A
80
7
0.12A
2D 38W
0.26A
55
5
0.14A
55
8
0.12A
54WT5
0.38A
65
3
0.21A
68
7
0.17A
PLL 36W
0.27A
84
6
0.15A
86
7
0.13A
PLL 40W
0.34A
85
3
0.18A
85
8
0.15A
PLL 50W
0.39A
77
3
0.20A
78
7
0.17A
PLL 55W
0.35A
62
3
0.18A
63
6
0.15A
PLT 32W
0.29A
91
5
0.15A
90
8
0.13A
PLT 42W
0.38A
89
2
0.20A
88
7
0.17A
FC9T5
2
0.43A
91
2
0.22A
92
8
0.19A
F25T8
0.49A
99
1
0.26A
95
7
0.22A
F26DBX
0.46A
93
1
0.24A
94
7
-2D 21W
0.37A
74
3
0.19A
74
7
0.16A
2D 28W
0.50A
120
1
0.26A
73
8
0.22A
PLL 24W
0.43A
50
2
0.22A
90
7
0.10A
PLL 36W
0.50A
76
1
0.27A
77
8
0.22A
PLT 26W
0.47A
96
1
0.25A
97
8
0.21A
PLT 32W
0.57A
87
6
0.30A
88
8
0.25A
MODEL #: FSD-B32PBM / FSD-B32PS -- Series
F32WT8
1
------0.16A
FC9T5
------0.10A
FC12T5
------0.15A
2D 21W
------0.09A
2D 28W
------0.12A
2D 38W
------0.12A
54WT5
------0.17A
PLC 26W
------0.11A
PLL 24W
------0.09A
PLL 36W
------0.13A
PLL 40W
------0.16A
PLL 50W
------0.16A
PLL 55W
------0.16A
PLT 26W
------0.11A
PLT 32W
------0.13A
PLT 42W
------0.16A
F25T8
2
------0.23A
FC9T5
------0.19A
2D 21W
------0.16A
2D 28W
------0.23A
PLC 26W
------0.20A
PLL 24W
------0.18A
PLL 36W
------0.24A
PLT 26W
------0.21A
PLT 32W
------0.26A
MODEL #: GSD-A18PBM / GSD-A18PS -- Series
F25T8
1
0.21A
73
2
0.11A
73
11
0.09A
FC9T5
0.19A
77
4
0.10A
77
11
0.08A
2D 16W
0.16A
75
8
0.06A
77
12
0.07A
2D 21W
0.16A
60
8
0.08A
60
12
0.07A
2D 28W
0.22A
58
2
0.12A
58
11
0.09A
2D 38W
0.23A
46
2
0.12A
45
11
0.10A
14WT5
0.16A
100
8
0.08A
100
10
0.01A
21WT5
0.22A
96
2
0.12A
99
11
0.10A
28WT5
0.31A
102
1
0.16A
103
11
0.14A
PLC 13W
0.15A
109
9
0.08A
109
11
0.07A
PLC 18W
0.18A
95
5
0.09A
96
11
0.08A
PLT 13W
0.15A
107
9
0.08A
107
12
0.07A
PLT 18W
0.18A
94
4
0.09A
95
10
0.08A
F17T8
2
0.27A
62
1
0.14A
62
11
0.12A
2D 16W
0.30A
73
1
0.15A
74
11
0.13A
14WT5
0.30A
99
1
0.16A
100
11
0.13A
PLC 13W
0.30A
109
<1
0.16A
110
11
0.13A
PLC 18W
0.35A
95
2
0.18A
95
10
0.15A
PLT 13W
0.29A
101
1
0.15A
101
11
0.13A
PLT 18W
0.38A
91
2
0.18A
91
10
0.15A
• All Multi-Voltage, Multi-Lamp Ballasts are all Rapid Start, High Power Factor ballasts
• Suffix “BM” - Bottom Mount with Studs (see page A23 for diagram)
L
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Capacitors
POWER FACTOR
CORRECTION CAPACITORS
A22
HPFCAP Series
Wiring Diagram
Ballasts
Lamp
Capacitor
H
Ballast
W
L
• Convert your normal power factor ballast to
high power factor by adding these capacitors
• Dry, non protected power factor modules
• Molded plastic case with metal tongue for
mounting
•
•
•
•
•
c
us
-25˚C to 80˚C temperature range
Capacitance tolerance: 5%
Rated voltage: 250VAC 50/60Hz
Withstand voltage: 1500V for one minute
11” 18ga TEW/AWM wire leads standard
Models Available
HPFCAP79 - for 7-8-9W Linear or Compact Fluorescent lamps
HPFCAP13 - for 1 X 13W Compact Fluorescent lamps
HPFCAP213 - for 2 X 13W CF or 1 X 18-22W Linear lamps
HPFCAP313 - for 3 X 13W CF or 1 X 25-40W Linear lamps
1.48”
1.48”
1.48”
1.48”
L
(37.5mm)
(37.5mm)
(37.5mm)
(37.5mm)
Dimentions
W
0.586” (15.0mm)
0.586” (15.0mm)
0.740” (18.9mm)
0.845” (21.5mm)
1.06”
1.06”
1.12”
1.33”
H
(26.9mm)
(26.9mm)
(28.6mm)
(33.8mm)
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Codes and
Styles
SUFFIX CODES AND
CASE STYLE DIMENSIONS
GUIDE TO BALLAST SUFFIX CODES
EXPLANATION
OPEN CORE
CLAMP CORE
ENCASED
PLUG-IN
9” LONG CAN
WITH CORD
SELF START
INTERNAL ELECTRONIC STARTER
HIGH POWER FACTOR
NORMAL POWER FACTOR
THERMALLY PROTECTED
WITH SINGLE BLOW TERMINAL FUSE
WITH SOCKET
FOR RECESSED JUNCTION BOX
BALLAST FACTOR
BALLAST CASE DIMENSIONS
CASE STYLE
LENGTH
(M)
A1
2.00
A2
A3
DIMENSIONS IN INCHES
WIDTH
(W)
(L)
A23
Ballasts
SUFFIX CODE
OC
CC
EN
PG
LC
WC
SS
IES
HPF / HP
NPF / NP
TP
PF
WS
RJ
BF
CASE CONFIGURATIONS
HEIGHT
(H)
2.36
1.10
1.42
2.50
3.11
1.85
1.34
2.80
3.27
1.54
1.97
A4
2.00
2.36
1.18
1.42
B1
2.25
2.75
1.50
1.20
B2
2.50
3.15
1.14
1.77
B3
2.00
2.36
1.41
1.40
B4
2.50
3.00
1.50
1.30
C1
6.00
6.61
2.36
1.57
C2
9.00
9.49
2.40
1.61
C3
3.75
4.02
1.93
1.50
C4
9.00
9.49
2.28
1.57
C6
6.00
6.61
1.89
0.98
C7
2.50
2.48
1.89
1.34
D1
6.00
6.46
1.89
1.42
D2
11.00
11.65
3.15
1.85
D3
4.33
4.76
2.17
1.57
D4
9.00
9.45
3.15
1.85
D5
2.80
3.15
1.48
1.14
D6
3.15
3.45
1.80
1.20
D7
9.00
9.49
1.65
1.15
E1
--
1.89
2.26
2.99
E2
--
1.61
1.97
2.36
E3
--
1.54
2.00
2.87
E4
--
1.77
1.89
2.56
F1
--
2.48
1.48
1.06
J
6.00
6.61
1.89
0.98
G1
6.00
6.46
1.89
1.42
G2
--
2.48
1.89
1.34
K
5.37
5.50
1.89
1.75
L1
6.00
6.46
1.89
1.00
L2
6.00
6.46
1.89
1.15
L3
8.90
9.45
1.80
1.37
L4
8.90
9.45
1.15
1.26
L5
8.90
9.50
1.70
1.15
M
6.00
6.46
1.37
1.00
N1
8.75
9.00
0.95
0.95
N2
7.25
7.50
0.95
0.95
P1
8.75
9.00
0.95
0.92
P2
7.25
7.50
0.95
0.95
S
3.12
3.45
1.81
1.21
T1
4.63
5.00
2.40
1.00
T2
4.63
5.00
3.00
1.38
U
14.00
14.40
1.23
1.03
V
5.60
5.90
0.91
0.76
Standard Side Exit
Standard Side Exit - Both Ends
Bottom Exit with Studs - RJ Type
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Ballast
Charts
A24
WIRE LEAD/ PACKAGING CHARTS
FOR MAGNETIC BALLASTS
STANDARD LEAD LENGTH - ENERGY SAVINGS (ES) SERIES
Ballasts
ITEM NUMBER
OPTION
YELLOW
--
WIRE COLOUR
BLUE
26” X 26”
WHITE
22”
BLACK
22”
QTY PER
SKID
500
QTY PER
CARTON
10
ES-140-1-TP
STANDARD
RED
34” X 34”
ES-140-2-TP
STANDARD
34” X 34”
--
26” X 26”
22”
22”
500
10
ES-240-1-TP
STANDARD
26”X 26”
37” X 37”
26” X 26”
22”
22”
500
10
ES-240-2-TP
STANDARD
26” X 26”
37” X 37”
26” X 26”
22”
22”
500
10
ES-232-1-TP
STANDARD
26” X 26”
37” X 37”
26” X 26”
22”
22”
500
10
ES-232-2-TP
STANDARD
26” X 26”
37” X 37”
26” X 26”
22”
22”
500
10
LW-240-1-TP
STANDARD
26” X 26”
37” X 37”
26” X 26”
22”
22”
500
10
ES-296-1-TP
STANDARD
48”
--
48”
72”
72”
288
6
ES-275-1-TP
STANDARD
48”
--
48”
72”
72”
288
6
ES-296-2-TP
STANDARD
48”
72” X 72”
48”
72”
72”
288
6
STANDARD LEAD LENGTH - NORMAL POWER FACTOR (N) SERIES
ITEM NUMBER
OPTION
WIRE COLOUR
BLUE
WHITE
19”
30”
30”
30”
20”
19”
18”
24”
12” X 12”
18”
QTY PER
SKID
830
QTY PER
CARTON
30
830
30
1120
10
1120
10
12”
650
20
16”
1350
30
--
16”
1350
30
--
16”
1350
30
12”
12”
830
20
12”
12”
830
20
12”
12”
650
10
12”
12”
650
10
12”
12”
650
10
12”
12”
1920
48
N-240-1-TP
STANDARD
STYLE 1
STANDARD
STYLE 1
STANDARD
RED
32” X 32”
30” X 30”
16” X 16”
15” X 15”
12” X 12”
YELLOW
----36” X 36”
N-234-1-TP
STANDARD
12” X 12”
36” X 36”
12” X 12”
18”
18”
N-220-1-TP
STANDARD
15” X 15”
23” X 23”
15” X 15”
12”
N-113A-1-TP
STANDARD
--
--
16”
16”
N-113-1-TP-IES
STANDARD
16” X 16”
16”
--
N-213-1-TP-IES
STANDARD
16” X 16”
16” X 16”
16” X 16”
N-122-1-TP-WS
STANDARD
N-140-1-TP-WS
STANDARD
N-2232-1-TP-WS
STANDARD
N-3240-1-TP-WS
STANDARD
ES-3240-1-TP-WS
STANDARD
CF-22-WS-TP
STANDARD
N-140-1-TP
N-120-1-TP
SOCKET ASSEMBLIES
ARE 9” FROM THE SIDE
OF THE BALLAST CASE
BLACK
14”
14”
12”
12”
18”
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Ballast
Glossary
Charts
WIRE LEAD/ PACKAGING CHARTS
FOR MAGNETIC/ ELECTRONIC BALLASTS
STANDARD LEAD LENGTH - COMPACT FLUORESCENT (CF) SERIES
ITEM NUMBER
QTY PER
SKID
4000
QTY PER
CARTON
50
CF-1320S SERIES
STYLE 1
7” X 15”
CC - 4800 / OC - 6000
60
CF-1322M SERIES
STYLE 2
6” X 12”
4000
50
CF-49 SERIES
STYLE 3
12” X 12”
5760
72
CF-579 SERIES
STYLE 3
12” X 12”
5760
72
Ballasts
STANDARD
WIRE COLOUR
BLACK
9” X 18”
CF-1322 SERIES
OPTION
A25
STANDARD LEAD LENGTH - ELECTRONIC BALLAST (EB) SERIES
ITEM NUMBER
OPTION
WIRE COLOUR
YELLOW
BLUE
-32”
WHITE
20”
BLACK
20”
QTY PER
SKID
490
QTY PER
CARTON
10
EB-232-1-TP
STANDARD
RED
48” X 48”
EB-232-2-TP
STANDARD
48” X 48”
--
32”
20”
20”
490
10
EB-232-3-TP
STANDARD
48” X 48”
--
32”
20”
20”
490
10
EB-232SL-1-TP STANDARD
48” X 48”
--
32”
20”
20”
600
30
EB-232SL-2-TP STANDARD
48” X 48”
--
32”
20”
20”
600
30
EB-232SL-3-TP STANDARD
48” X 48”
--
32”
20”
20”
600
30
EB-332-1-TP
STANDARD 48” X 48” X 48”
--
32”
20”
20”
490
10
EB-332-2-TP
STANDARD 48” X 48” X 48”
--
32”
20”
20”
490
10
EB-432-1-TP
STANDARD
32” X 32”
48” X 48”
32” X 32”
20”
20”
490
10
EB-432-2-TP
STANDARD
32” X 32”
48” X 48”
32’ X 32”
20”
20”
490
10
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Glossary
BALLAST GLOSSARY
Ballasts
A26
2-Pin Compact Fluorescent Lamps
A type of lamp that has the glow bottle
starter built into the base of the lamp.
Traditionally 2-pin lamps are designed for
magnetic ballasts.
Class B
An operating temperature classification
for electrical components established by
UL. Class B allows operation up to
130ºC.
Grounding
The connection on an electrical
conductor with the earth, so that the
electricity passed off into it. Ballast
cases must be grounded.
Auto-Transformer
A transformer in which the primary and
secondary coils are electrically connected
together. Most ballasts use this circuit to
make them smaller, less costly, and more
efficient.
Class H
An operating temperature classification
for electrical components established by
UL. Class H allows operation up to
180ºC.
Harmonic Distortion
Distortion of an AC waveform caused by
multiples of the fundamental frequency
(harmonics). Odd triplen harmonics
(thirds, ninths, etc.) may result in large
currents on the neutral line in a four wire
Wye three-phase system.
Ballast Factor (Light Output)
A measure of the light produced by a
lamp operated by a ballast compared to
the light produced by a laboratory
standard lamp operated by a reference
ballast. Expressed as a percentage.
Class P
The UL classification for thermally
protected ballasts. Indoor fluorescent
fixtures are required to have thermally
protected ballasts. Internal thermal
protector removes input power whenever
specified temperature limits are
exceeded, about 100-110ºC.
Ballast Losses
This is the wattage loss internal to the
ballast and is power not used for
producing light. These losses are
dissipated as heat. Ballast losses
account for most of the difference
between lamp efficiency and system
efficiency.
Compact Fluorescent
A family of single-ended fluorescent
lamps that are self-supporting. They are
usually arranged in twin, quad, or hex
shapes with a variety of base
arrangements.
BEF (Ballast Efficiency Factor)
This is the ratio of ballast light output to
the input power. Used to compare
different ballasts on a light output to
power consumption basis. BEF = % light
output / input power (watts)
Case Temperature
The hottest spot on the outside of the
ballast case.
Cathode Heat
The voltage or power supplied to the
lamp cathodes (electrodes) in rapid start
and preheat start circuits. This voltage
brings the cathodes to the proper
operating temperature. In rapid start
circuits, the cathode heat voltage is
nominally 3.6V.
Circuit Interrupting Lampholder
(Disconnect Lampholder)
A safety device required by UL when
certain voltage limits are exceeded.
Consists of a lampholder that
incorporates a switch that opens and
closes when lamps are inserted or
removed from the lampholder. Input
power is removed from the ballast
whenever a lampend is out of a socket.
Crest Factor
A function of the ballast, it is the ratio of
the peak current value divided by the
RMS current value. May be voltage or
current crest factor. Usually high current
crest factors result in reduced
performance and ballast life.
Efficiency
As a measure of the ability to produce
light, it is lumens per watt (LPW). True
efficiency as a measure of its power
pass-through would be the power
delivered to the load divided by the total
input power.
Electrode (Cathode)
Metal filaments that emit electrons in a
fluorescent lamp. Negatively charged
free electrons emitted by one electrode
are attracted to the positive electrode
(anode), creating an electric current and
arc between electrodes.
Electromagnetic Ballast
A ballast that operates principally through
the use of current carrying copper or
aluminum coils assembled on a magnetic
steel core, instead of electronic
components, to operate lamps.
HO (High Output)
A family of rapid start lamps and ballasts
which run at 800mA nominal current.
HPF (High Power Factor)
Power factors that are greater than 90%
and have been corrected above 90%.
Indoor
A usage or application classification of
ballasts by UL. An indoor ballast is only
acceptable for use indoors, and will start
lamps down to 50ºF (60ºF for energy
saving lamps).
Instant Start
Method of starting lamps by applying an
initial high voltage to break down the arc
tube and initiate the flow of current.
During the starting the cathode should
establish the hot spot in 15 to 30
milliseconds. Usually identified by the
single pin base. No preheating of the
filament is required.
Also a line of ballasts and lamps that
utilize instant start usually T12 at 425mA,
but also T8 and T6 at 300mA, 2’-8’ with
single pin bases.
Life
The rated life of a ballast is defined as
the time to failure for the 50th percentile
(the time for half of a large population of
ballasts to fail). Some ballasts will fail
before the rated life and some will
continue to operate beyond the rated life.
Standard electromagnetic ballasts have a
life of approximately 40,000 to 60,000
hours.
Life of a ballast is inversely related to the
operating temperature. For each 10ºC
change in case temperature causes a 2
times change in life.
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Glossary
BALLAST GLOSSARY
NPF (Normal Power Factor)
Power factors that have not been
corrected above 90%. Typically an
uncorrected power factor is 40-60%.
Parallel Circuit
A type of circuit in which the electrical
path splits to permit the current flow in
both paths simultaneously. This operates
each lamp independently, allowing one
lamp to operate if the other one fails.
Potting Compound
The solid material that fills the inside of
the ballast, usually a mixture of asphalt
and silica used to dampen sound and
dissipate heat.
Power Factor
A measure of how efficiently the ballast
utilizes the input amps to generate the
power delivered to the lamps, ie. the
relationship between AC source voltage
and current. A high power factor (HPF)
ballast uses less amps than a normal
power factor (NPF) ballast for the same
load. Technically, the power factor is the
ratio of the real power to the apparent
power. Real power is in watts, as
measured with a wattmeter. Apparent
power is input volts times input amps,
measured with voltmeters and ammeters.
It is expressed as a percent or a number
from 0 to1.
Power factor is a concern because using
a NPF ballast in place of a HPF ballast
may overload some circuits. Also, some
power companies charge a penalty for
users with normal power factor.
Preheat Start
A circuit where the lamp electrodes are
heated by a switch, glow bottle starter, or
electronic circuit prior to operating the
lamp. When the filaments have heated
up, the starter opens and the ballast then
provides a suitable voltage to light the
lamp and limits the current flow to the
proper value. Several seconds are
required to complete the starting
operation. Preheat lamps must use
preheat ballasts.
Rapid Start
A circuit where the electrode heating
voltage and the starting voltage are
applied to the lamp simultaneously
through small, low-voltage filament
windings. The open circuit voltage of the
ballast is adequate to start the lamp only
after the filaments have heated to
emission temperature, and the lamps
light when the electrodes have reached
the proper temperature. The electrode
heat remains on all the time the lamps
are burning (continuous cathode heat).
Also a family of lamps and ballasts that
utilize continuous electrode heat. The
family may contain the F40 line, which
runs at 430mA, the HO line, which runs
at 800mA, and the PG/VHO/SHO line,
which runs at 1500mA.
RJ (Rear Junction box)
A configuration with crew studs mounted
on the base plate or bottom of the
ballast. The screws are 3/8" long with a
#8-32 thread size. They are mounted on
a 2" center. The studs are usually used
to mount the ballast directly onto a
junction box plate. Because metal can
ballasts are usually larger than the
junction box plate, the studs are used to
mount the ballast directly to the junction
box plate.
Side Exit
A configuration with leads exiting either
one or both sides of the ballast. Side exit
ballasts are usually preferred for use in
wall sconces and surface mount fixtures.
Slimline
A family of ballasts and lamps that use
the instant start circuitry. The lamps
have single pin bases and is most often
T12, T8, and T6.
Starter
May be a fluorescent or HID starter. A
fluorescent starter is used to heat the lamp
electrodes prior to starting. The metal of a
fixture is a starting aid when grounded
properly. T12 lamps with 40W or less
must be mounted within 1/2" of a grounded
metal surface. T8 lamps must be mounted
within 5/8" of a grounded metal surface.
All other lamps must be mounted within 1"
of a grounded metal surface.
T6, T8, T10, T12
The designation used to describe
different fluorescent lamps by their
outside diameter. This alphanumeric
portion of the designation refers to the
lamp’s diameter in 1/8" increments. (T12
= 12 x 1/8" = 1 1/2")
Temperature Rise
A means of measuring the operating
temperatures in a ballast, usually
specifying a temperature rise above a
given ambient temperature. Another
method of specifying temperature is
absolute, used when a certain maximum
temperature, irrespective of ambient
should not be exceeded.
THD (Total Harmonic Distortion)
The combined effect of harmonic
distortion on the AC waveform produced
by a ballast or other device. Expressed
as a percentage. Excessive levels of
THD can create large currents on the
neutral line of a four-wire Wye threephase system.
Thermal Protector
A device inside of the ballast, which
senses the temperature and will
disconnect the input power whenever the
limit is exceeded. This usually consists
of a bimetal switch. This protection
guards against excessive temperatures,
which may be caused by abnormal
voltage.
Thermal protection may be of two
varieties, automatic resetting or nonresetting (like a fuse). When a nonresetting protector operates, the ballast
may be permanently inoperable, and
must be replaced. If the thermal
protector meets certain UL specifications,
the ballast can be classified as "Class P".
Trigger Start
A variation of the preheat start circuit, the
ballast operates preheat lamps in a rapid
start manner by suppling continuous
voltage to the electrodes to heat them to
the proper temperature. Upon starting,
the electrode voltage is reduced about
one half to reduce the losses.
UL (Underwriters Laboratories Inc)
Laboratory that sets safety standards for
building materials, electrical appliances
and other products.
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A27
Ballasts
Metal Cases
Case design used in both magnetic and
electronic ballasts. Metal case ballasts
are generally larger than plastic case
ballasts and use a potting compound to
dissipate heat and sound. These ballasts
are grounded once they are mounted to
the fixture. They meet safety codes,
some of which do no allow plastic in
open plenum areas.
Download