sales@atcsemitec.co.uk Tel: +44(0)1606 871680 Fax: +44(0)1606 872938 ATC Semitec Ltd Unit 14 Cosgrove Business Park Daisy Bank Lane, Anderton NORTHWICH Cheshire CW9 6FY U.K SEFUSE SF/K Series Thermal Fuses Our SF/K type is a smaller version of our SF/E series but still uses an organic thermosensitive pellet inside a metal case. It features a large cutoff (rated) current of up to 10A/250VAC. ■ Marking 1 (SF70K~SF119K) ■ Marking 2 (SF188K, SF214K) SEFUSE SF 70K 73° C 6A 250V~ <PS>E JET Rated Current PSE Mark SEFUSE SF188K 192° C 6A 250V~ <PS>E JET Brand Name Part Number Rated Functioning Temperature Rated Current Rated Voltage PSE Mark Inspector Name 0365 0365 Lot Number How to read a lot number ex.) 03 6 5 Brand Name Part Number Sub-lot number Rated Functioning Temperature Month X….October Y….November Z….December Last two digit of year Rated Voltage Inspector Name Lot Number Ratings Meet for1) WEEE (RoHS) Part Number Rated Functioning Temperature Tf (°C) Operating Temperature Holding Temperature (°C) Th (°C) SF 70K 73 70 ± 2 45 SF 76K 77 76 ± 0 4 51 SF 91K 94 91 ± 3 1 66 SF 96K 99 96 ± 2 71 SF119K 121 119 ± 2 94 SF188K 192 188 ± 31 164 SF214K 216 214 ± 13 198 Maximum Temperature Limit Tm (°C) UL· c-UL Rated Current Rated Voltage Thailand VDE Thailand BEAB Thailand CCC KTL PSE Thailand Thailand SU05020 -XXXXX Thailand JET197432001-XXXX 2) 1003 5004 150 6A (Resistive) 300 AC250V E71747 677802 -1171 -0006 C1180 3 1002 1) 5006 1004 5007 1007 5008 1008 1: 2008010205282881 Note: 1) No use the hazardous substances prescribed by WEEE (RoHS) 2) The following electrical ratings were used for the UL, VDE, and TKL safety standards: 10A (Resistive) / AC250V. 3) The following SF-types have passed the Conductive Heat Aging Test (CH) specified by the UL safety standard: SF188K and SF214K.. SF/K – 01/02/12