CITY OF CHICAGO DEPARTMENT OF CONSTRUCTION AND PERMITS
GENERAL BUILDING REQUIREMENTS Per Chicago Zoning Ordinance(CZO) and Chicago Building Code (CBC) 2004 Edition
Item
Issue
Chapter/Article
Ordinance
Requirmnt
Actual
Requirmnt
N/A
Location/
Sheet No.
Agency/
Test No.
Remarks
CIVIC FEDERATION
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
PART 1- ZONING REQUIREMENTS
PART 2 - BUILDING REQUIREMENTS
Occupancy Classification(s)
3 (13-56) page 115
E
E
-
A1
-
Business
Height and Area Limitations
5 (13-48) page 323
-
-
N/A
-
-
No Change to Building
-
-
N/A
-
-
a)Exceptions to Area Limitations
5(13-48-090)pg.325
b)Mixed Occupancy Buildings
5(13-48-100)pg. 326
Types of Construction
6(13-60) page 329
Mixed Occupancy Separations
3(13-56-280)pg.118
Occupant Load
3(13-56-320)
Req.Hrs of Fire Resistance
6(13-60-100)pg. 330
Exterior Bearing Walls
-
-
N/A
-
-
I-A
I-A
-
A1
-
-
-
N/A
-
-
1/100 Sq. Ft.
48
-
A7
-
Business: 4,858/100 = 48 persons max. allowed
Table 6(13-60-100)
NC
NC
N/A
-
-
No Change to Building
Exterior -Nonbearing Walls
Table 6(13-60-100)
NC
NC
N/A
-
-
No Change to Building
Interior Bearing Walls
Table 6(13-60-100)
NC
NC
N/A
-
-
No Change to Building
Interior Nonbearing Walls
Table 6(13-60-100)
1 Hr
1 Hr
-
A10
-
Project Complies
Columns
Table 6(13-60-100)
NC
NC
N/A
-
-
No Change to Building
Columns Supporting Roofs Only
Table 6(13-60-100)
NC
NC
N/A
-
-
No Change to Building
Beams
Table 6(13-60-100)
NC
NC
N/A
-
-
No Change to Building
Beams Supporting Roofs Only
Table 6(13-60-100)
NC
NC
N/A
-
-
No Change to Building
Floor Construction
Table 6(13-60-100)
NC
NC
N/A
-
-
No Change to Building
Roof Construction
Table 6(13-60-100)
NC
NC
N/A
-
-
No Change to Building
Elevator Framing
6(13-60-130)pg.331
NC
NC
N/A
-
-
No Change to Building
Driveways and Loading Spaces
6(13-60-210)pg. 332
-
-
N/A
-
-
No Change to Building
Fire - Resistive Requirements
7(15-8) page 335
No Change to Building
a)Fire Walls - Construction
7(15-8-010)page 335
-
-
N/A
-
-
No Change to Building
b)Parapets
7(15-8-100)p335
-
-
N/A
-
-
No Change to Building
c)Stairway Enclosures
7(15-8-140)pg.337
-
-
N/A
-
-
No Change to Building
d)Elevator Enclosures
7(15-8-150)pg 337
-
-
N/A
-
-
No Change to Building
e)Enclosures of Heating Rooms
7(15-8-190)pg 338
-
-
N/A
-
-
No Change to Building
f)Enclosures of Wells & Chutes
7(15-8-170)pg 338
-
-
N/A
-
-
No Change to Building
f1)Enclosures of pipe shafts and ducts
7(15-8-160)pg 338
-
-
N/A
-
-
No Change to Building
-
N/A
-
-
No Change to Building
-
A7
-
Flame Spread of 26 - 75
g)Other Enclosures
7(15-8-240)pg.339
h)Interior Wall and Clg.Finishes
7(15-8-380)pg.341
I)Storage Rooms over 100sq.ft
7(15-8-240)(b)pg.339
-
-
NA
A8
-
No Change to Building
2.11
Fire - Resistive Materials and Construction
7(15-12)page 348
-
-
NA
-
-
No Change to Building
2.12
Accepted Engineering Practice
7(15-12-050)
-
-
NA
-
-
No Change to Building
2.13
Fire Protection Equipment
9(15-16) page 361
-
-
-
-
-
No Change to Building
a)Sprinkler Systems
9(15-16-010)pg 362
-
-
-
FP1
-
See Engineering Drawings
b)Special Requirements
9(15-16-030)pg 362
-
-
-
-
-
No Change to Building
-
-
-
No Change to Building
NR
Class 2
Class 2
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
PROJECT DIRECTORY
Tenant:
Civic Federation
177 N. State Street, Suite 400
Chicago, Illinois 60601
(312) 201-9041
Architect:
Garnett Architects, LLC
140 South Dearborn, Suite 410
Chicago, Illinois 60603
(312) 447-0747
NEW AREAS OF WORK
General Contractor:
Bear Construction
1431 North Western Ave.
Chciago, IL 60622
(773) 360-7570
PART 3 - EXIT REQUIREMENTS
Types of Exits
10(13-160-040)pg 388
Existing
Minimum Number of Exits
10(13-160-050)pg 388
2 Per Floor
2
-
A8
-
See Drawings
Travel Distance to Exits
10(13-160-110)pg 389
150'
99'
-
A8
-
Maximum Travel Distance Indicated On Plan
a)Increases Permitted
10(13-160-150)pg 390
50%
50%
-
-
-
Standard Sprinkler System
b)Dead End Corridor
10(13-160-160)pg.390
-
Existing
75'
75'
A8
Doors
= 60 / Unit
See
Drawings
-
A8
Capacity of Exits
3(13-84-180)pg 136
Minimum Width of Exits
10(13-160-220)pg 391
36" wide doors
See Drawings
-
Swing of Exit Doors
10(13-160-250)pg 391
As Required
See Drawings
-
Hardware
10(13-160-260)pg 392
As Required
See Drawings
-
Landings
10(13-160-310)pg 394
-
-
N/A
Handrails
10(13-160-320)pg 394
-
-
-
Exisiting Condition
A8
-
Entrance/Exit doors 36"-72"
A8
-
Doors swing in the direction of egress
-
Keyless in direction of egress
-
-
Existing Condition
N/A
-
-
Existing Condition
Construction
10(13-160-330)pg 394
Existing
NC
N/A
-
-
Existing Stairs
Enclosures
7(15-8-140)pg 337
Existing
Existing
N/A
-
-
Existing Stairs
Head Room
10(13-160-350)pg 394
7'-0"
8'-0"
N/A
-
-
Existing Stairs
Building Representative:
REDICO
Real Estate Development and Investment Company
One Towne Square, Suite 1600
Southfield, Michigan 48076
LIST OF DRAWINGS
PART 4 - ACCESSIBILITY REQUIREMENTS
New Construction
IAC 400.310
-
-
N/A
-
-
Accessible Route
IAC 400.310(a)
-
-
N/A
A8
-
See Drawings - Project Complies
Areas of Rescue Assistance
IAC 400.310(b)
-
-
N/A
-
-
No Change to Building
Curb Ramps
IAC 400.310 (d)
-
-
N/A
-
-
No Change to Building
Ramps
IAC 400.310 (e)
-
-
N/A
-
-
No Change to Building
Stairs
IAC 400.310 (f)
-
-
N/A
-
-
No Change to Building
Elevators
IAC 400.310 (g)
-
-
N/A
-
-
No Change to Building
Doors
IAC 400.310(j)
36"
36"
N/A
-
-
Project Complies
Accessible Entrance
IAC 400.310(k)
-
N/A
-
-
Project Complies
Drinking Fountain
IAC 400.310 (l)
Hi - Lo
-
N/A
-
-
Available in common corridor
Toilet Rooms
IAC 400.310(n)
-
-
N/A
-
-
No Change to Building
Controls & Operating Mech.
IAC 400.310(r)
Reach Range
-
-
-
-
Project Complies
Alarms
IAC 400.310(s)
-
-
-
-
-
New Will Be Synchronized
Detectable Warnings at Stairs
IAC 400.310(t)
-
-
-
-
-
No Change to Building
Signage
IAC 400.310(u)
-
-
-
-
-
Existing Signage Complies
Telephones
IAC 400.310(v)
-
-
-
-
-
No Change to Building
Business and Mercantile
IAC 400.320(h)
-
-
-
-
-
Project Complies
Alteration
IAC 400.510 (b) (1)
-
-
-
-
-
Project Complies
1
8TH FLOOR KEY PLAN
SCALE:
NORTH
NOT TO SCALE
ENERGY CONSERVATION CODE COMPLIANCE STATEMENT
PROJECT LOCATION
PART 6: VENTILATION/FURNACE
Outside Air Intake
28(13-176-090)
-
-
N/A
M1
-
Project Complies
Minimum Amount of Air
28(13-176-070)
50 CFM
-
N/A
M1
-
Project Complies
Ductwork
28(13-176-160)
Sheet Metal
-
-
M1
-
Project Complies
Transfer Ducts
28(13-176-170)(e)
5'-0"
-
-
M1
-
Project Complies
Type K Copper
-
N/A
M1
-
Project Complies
Brazed
-
N/A
M1
-
Project Complies
See Comment
-
N/A
M1
-
Project Complies
MEFP Consultants:
Kent Consulting Engineers
2015 Spring Road, Suite 240
Oak Brook, Illinois 60523
(630) 684-0234
A1
A1.2
A2
A3
A4
A5
A6
A7
A8
A9.1
A9.2
A10
A11
A12
A13
A14
PROJECT INFORMATION
SCHEDULE
LEGEND SHEET
8TH FLOOR DEMOLITION PLAN
8TH FLOOR ARCHITECTURE PLAN
8TH FLOOR REFLECTED CEILING PLAN
8TH FLOOR POWER AND COMMUNICATION PLAN
8TH FLOOR FINISH PLAN
8TH FLOOR FURNITURE PLAN
ELEVATIONS
ELEVATIONS
PARTITION TYPES AND DETAILS
MILLWORK DETAILS
DOOR TYPES AND DETAILS
SPECIFICATIONS
SECIFICATIONS
M1
M2
M3
E1
E2
E3
E4
P1
P2
FP1
MECHANICAL NOTES AND SCHEDULES
MECHANICAL DEMOLITION PLAN
MECHANICAL PLAN
ELECTRICAL SPECIFICATIONS
ELECTRICAL POWER PLAN
ELECTRICAL LIGHTING PLAN
EMERGENCY LIGHTING PLAN
PLUMBING NOTES
PLUMBING PLAN
FIRE PROTECTION
I certify that I am a Registered Energy Professional (REP). I also
certify that to the best of my professional knowledge and belief that
the attached plans for 10 North Dearborn Street fully comply with the
requirements of Chapter 18-13, Energy Conservation, of the
Municipal Code of Chicago, except 18-13-303.1.
Signed______________________________________Date:03/13/15
PART 7: REFRIGERATION
Pipe Size and Material Grade
28(13-192-430
Means of Joining Piping
Air Stream Requirements
28(13-192-380)
Size/Location of Safety Valve
28(13-192-520 to 560)
Size/Location of Vent Line
28(13-192-670)
High Side
-
N/A
M1
-
Project Complies
Relief Valve
-
N/A
M1
-
Project Complies
NO.
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
This is to certify that these drawings were prepared under my
supervision and that to the best of my knowledge, comply with the
The City of Chicago Building Code.
PART 8: PLUMBING
Plumbing Fixture Count
18-29-403
-
-
-
P1
-
Project Complies
Water Heater
18-29-503-504
-
-
-
P1
-
Project Complies
Plumbing Fixture Schedule
18-29-401 to 425.4
-
-
-
P1
-
Project Complies
Material for water,waste & vent
18-29-702
-
-
-
P1
-
Project Complies
Isometric Piping Diagrams
18-29-105
-
-
-
P1
-
Project Complies
______________________________________
Jack M. Janowiak, License #001-014742
Licensed Architect, State of Illinois, Expires 11/30/2016
Sheets:
A1 - A14
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
Date: 03/13/15
PART 9: ELECTRICAL
Single Line Drawing
-
-
-
E1
-
Project Complies
Emergency Source
18-27-700.5
-
-
-
E1
-
Project Complies
Non Utility Source of Power
18-27-700.6
-
-
-
E1
-
Project Complies
PROJECT INFORMATION
2
LOCATION PHOTO
SCALE:
NOT TO SCALE
NORTH
PROJECT NUMBER:
0213
DRAWING SCALE:
AS NOTED
SHEET NO:
A1
FINISH SCHEDULE
FINISH SCHEDULE
DOOR HARDWARE SCHEDULE
HARDWARE SET NO. 1 - OFFICE LOCKSET
WALL FINISHES:
P
1
PAINT P-1: (GENERAL)
BENJAMIN MOORE, #2124-70, DISTANT GRAY
P
2
PAINT P-2: (PRIVATE OFFICE ACCENT)
BENJAMIN MOORE, #CSP-105 SMOKE AND
MIRRORS
P
3
PAINT P-3: (BOARDROOM ACCENT)
SHERWIN WILLIAMS, #SW0038 LIBRARY
PEWTER
SD-4
P
4
WC
1
WC
2
WALLCOVERING WC-2:
MDC
STYLE: LIBRARY, NEWSPRINT
PATTERN: PAZ6405/4543
WALL BASE:
B
1
TYPICAL VINYL BASE, 2.-1/2"
JOHNSONITE #08 ICICLE WITH 275 VEGETATE
B
2
TYPICAL VINYL BASE, 2-1/2"
ALLSTATE, #D48
B
3
TYPICAL VINYL BASE, 2-1/2"
JOHNSONITE #281 GRIZZLY WG
B
4
TYPICAL VINYL BASE, 2-1/2"
JOHNSONITE #29 MOON ROCK
FLOOR FINISHES:
CARPET 1: (GENERAL CARPET)
SHAW CONTRACT GROUP
STYLE: HAZE TILE 5T037
COLOR: SMOKE 37557
CONTACT: JANET MICELI C. 773.771.0916
GL-1
CPT
1
CLG1:
ACT-1, ACOUSTIC 2X2 OPEN OFFICE CEILING:
9
ARMSTRONG, OPTIMA, 16
" SQUARE TEGULAR, 3251 , WHITE, 4" AXIOM TRIM
EDGE.
PROVIDE 9/16" GRID GR-1 AT ACT-1 LOCATIONS:
CEILING GRID GR-1:
ARMSTRONG SILHOUETTE 81" REVEAL. COLOR: WHITE.
CLG2:
ACT-2, 2X2 ACOUSTIC TYPICAL CEILING, WHITE:
9
ARMSTRONG, ULTIMA, 16
" BEVELED TEGULAR, 1912, WHITE
CEILING GRID GR-2:
ARMSTRONG SILHOUETTE 81" REVEAL. COLOR: WHITE.
CLG3:
ACT-3, 2X4 ACOUSTIC BOARDROOM CEILING, WHITE:
9
ARMSTRONG, ULTIMA, 16
" BEVELED TEGULAR, 1915, WHITE
CEILING GRID GR-2:
ARMSTRONG SILHOUETTE 81" REVEAL. COLOR: WHITE.
HARDWARE SET NO. 3 - STOREROOM LOCKSET
HARDWARE SET NO. 4 - CLOSET PIVOT, PAIR
2 - HALF DUMMY TRIM: SCHLAGE, L0170, LEVER 07, ROSE A, BHMA 630
2 SETS - PIVOT HINGES: RIXSON, #370 (TOP) #340 (BOTTOM)
2 - CONCEALED OVERHEAD STOP: ABH, 4024 (36 IN. DOOR) OR 4023 (<35 IN.
DOOR), BHMA 630
2 - ROLLER LATCH W/ ANGLE STOP: ROCKWOOD, 593, BHMA 630
HARDWARE SET NO. 5 - CARD READER ENTRY
HARDWARE SET NO. 6 - CARD READER ENTRY
1 - ELECTRIC HINGE: STANLEY CEFBB179 4 1/2" X 4 1/2", BHMA 630
3 - BUTT HINGES: STANLEY, FBB 179 4 1/2 X 4 1/2, BHMA 626
EQ
#
F2
F3
F4
F5
WOOD FLOOR (RECEPTION)
DUCHATEAU
VERNAL COLLECTION
VERNAL COMO, EUROPEAN OAK
CONTACT: SANDRA MOAD T. 619.793.5899
PLASTIC LAMINATE 1:
FORMICA
COLOR CORE 2
NEW WHITE 7223C-90
GLOSS FINISH
EQ
3
EQ-3 COPIER BY OWNER (NETWORK)
EQ
4
EQ-4 TV BY OWNER, INSTALLED BY GC
EQ
5
EQ-5 POSTAGE MACHINE BY OWNER
F3 - LINEAR SUSPENSION (OPEN OFFICE)
CORELITE, JAYLUM SUSPENDED, FROSTED
LENS
J2-SL-2N5-AC18-TS-12
F4 - LED PENDANT:OPEN OFFICE
IMPACT ARCHITECTURAL LIGHTING,
bul.it.LED,
P3316.LED 35HI SB BKPC, 16" DIA., 3500K,
SATIN BLACK, BLACK POWER CORD AND
CANOPY
F5 - LINEAR SUSPENSION (8' WALL WASH)
ALW, NOVENTA
NV3.5S- 8'- T5S2-DIM-BK
F7
F7 - LINEAR SUSPENSION (8' REDCEPTION)
ALW, NOVENTA
NV3.5- 8'- T5S2-DIM-BK
F8 - UNDERCABINET LIGHTING, MERCURY
LIGHTING, SERIES MUC1, MINI
UNDERCABINET. LENGTHS AS NOTES
BELOW.
F8A - 36" LENGTH
MUC1-121-T5-UG-A-120V-LWW
PLASTIC LAMINATE 2:
FORMICA
WHITE 9449-90
GLOSS FINISH
EQ-2 MICROWAVE, BY GC
GE, JES1451DSWW, WHITE
MICROWAVE-COUNTERTOP
12.5"H X 21-7/8"W X 16-3/8"D
F1 - 2X4 LAY-IN FLUORESCENT LIGHT
FIXTURE, CORELITE, CLASS R2, FROSTED
PRISMATIC LENS
R2-WL-2N5-24-TI-CP (CHICAGO PLENNUM)
F6 - LINEAR SUSPENSION (6' SUSPENDED)
ALW, NOVENTA
NV3.5S- 6'- T5S2-STD-BK
F8
EQ-1 REFRIGERATOR BY GC
WHIRLPOOL, WRF535SMBW 25CF, WHITE
70"H X 36"W X 35.5"D
GC TO PROVIDE WATER LINE
EQ
2
F6
MILLWORK FINISHES:
EQUIPMENT SCHEDULE
LIGHT FIXTURE SCHEDULE
F2- 2X2 LAY-INFLUORESCENT LIGHT
FIXTURE,CORELITE, CLASS R2, FROSTED
PRISMATIC LENS
R2-WL-2N5-22-TI-CP (CHICAGO PLENNUM)
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
2 - CONCEALED CLOSERS: LCN, 3130 SERIES, POWDER COAT
EQ
1
F1
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
CLG4:
DRYWALL CEILING, PAINTED.
VINYL TILE
ARMSTRONG EXCELON
STYLE: CHAMPION SQUARE
COLOR: 51973 MONO WHITE
SIZE: 12"X12"
THICKNESS: 1/8"
CONTACT: JAMIE PIKOLAS T. 717.396.4170
WD-2
LEVER 07, ROSE A
FLOORING TRANSITION TARGETS
CEILING SCHEDULE
LUXURY VINYL TILE
BENTLEY
TERRENE COLLECTION
STYLE: PBEAM06X36
COLOR: BREEZY 800585
SIZE: 6" X 36"
THICKNESS: .118"
CONTACT: BETH GHADIMI C.312.965.3345
PL-3
1/4" CLEAR TEMPERED GLASS
1
VCT
CARPET 3: (RECEPTION)
FLOR
STYLE: RAKE ME OVER
COLOR: GRAPHITE 21-1050-07
CONTACT: KATELIN CONNEALY T.312.923.8189
PL-2
HARDWARE SET NO. 2 - MEETING ROOM LATCHSET
LEVER 07, ROSE A
CARPET 2: (PRIVATE OFFICE CARPET)
SHAW CONTRACT GROUP
STYLE: HAZE TILE 5T038
COLOR: DELICATE 37515
CONTACT: JANET MICELI C. 773.771.0916
PL-1
SOLID SURFACE (BOARDROOM)
DIRESCO
COLOR: SUPREME WHITE
NUMBER: S100, POLISHED
CONTACT:
GLAZING:
PAINT P-4: (ACCENT COPY AREA)
BENJAMIN MOORE, #CSP-115 BARNWOOD
WALLCOVERING WC-1: RECEPTION
MAHARAM, HERRING 399614
COLOR:006
LEVER 07, ROSE A
WALL FINISHES:
EQ
6
EQ-6 DISHWASHER BY GC
WHIRLPOOL GOLD SERIES, WDT720PADW, WHITE
34"H X 23 3 4"W X 24.5"D
GE TO PROVIDE WATER LINE
EQ
7
EQ-7 ELECTRIC STAPLER BY OWNER
EQ
8
EQ-8 PAPER SHREDDER BY OWNER
EQ
9
EQ-9 PRINTER (PERSONAL) BY OWNER
EQ
10
EQ10 COFFEE MAKER BY OWNER
EQ
11
EQ11 ELECTRIC TEA POT BY OWNER
EQ
12
EQ12 FAX MACHINE BY OWNER
PLUMBING FIXTURE SCHEDULE
SINK 1: (UNDERMOUNT)
ELKAY, ELUHAD2816, STAINLESS STEEL UNDERMOUNT SINK
KOHLER, PURIST, PULL-OUT KITCHEN FAUCET, K-7505.
PROVIDE UNDER-COUNTER WATER FILTER SYSTEM: EVERPURE, QL3B SINGLE
HEAD EV9259-24 W/ OW4-PLUS FILTER CARTRIDGE EV9635-01; ELKAY LK1110
F8B - 48" LENGTH
MUC1-128-T5-UG-A-120V-LWW
PLASTIC LAMINATE 3:
ARPA
TEX FINISH 3317
F9
WOOD VENEER 2:
DOOR MANUFACTURERS STANDARD WOOD
VENEER. PLAIN SLICED WALNUT. STANDARD DARK
STAIN TO MATCH ARCHITECT'S SAMPLE.
F10
F9 - SQUARE LED DOWNLIGHT
COOPER LIGHTING BY EATON, PORTFOLIO
LDSQ4ACP-13D010TE-ESQ4A13835CP-4LSQ1H
(CHICAGO PLENUM)
F10 - SQUARE LED LENS WALL WASH
COOPER LIGHTING BY EATON, PORTFOLIO
LDSQ4ACP-13D010TE-ESQ4A13835CP-4LSQLWW1H
(CHICAGO PLENUM)
WALL TILE:
SD-3
SOLID SURFACE (RECEPTION DESK)
DIRESCO
COLOR: PURE WHITE
NUMBER: A250, POLISHED
CONTACT:
F12
b
SOLID SURFACE (RECEPTION DESK)
CAESARSTONE
CLASSICO COLLECTION
COLOR: CONCRETE
NUMBER: 2003
SOLID SURFACE (CAFE COUNTER)
CAESARSTONE
CLASSICO COLLECTION
COLOR: PURE WHITE
NUMBER: 1141
D
F11 - RECESSED FLUORESCENT FIXTURE (26
FEET LENGTH)
NULITE, REGOLO 6 GRID SERIES
RG6-2T5-S-ST-D-26'
NO.
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
F12 - DECORATIVE PENDANT (17" WIDTH)
LIGHTOLOGY, CASTORE, ART2187, WHITE,
WHITE BODY, 150W INCANDESCENT.
#0112SU-CASTORE-017I1-WHWH
"b" LOWER CASE SUBSCRIPT AT LIGHT FIXTURE AND
CORRESPONDING SWITCH INDICATES SWITCHING
S
SD-2
F11
WALL MOUNTED TOGGLE SWITCH
S
SD-1
GLASS TILE 1: BACKSPLASH
L'ANTIC COLONIAL
TREASURES NUDE NEPAL MOON
SIZE: 19X29 MOSAIC
WALL MOUNTED DIMMER SWITCH
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
SCHEDULES
3
S
GT-1
WALL MOUNTED 3-WAY SWITCH
PROJECT NUMBER:
CEILING HEIGHT TARGET, DISTANCE FROM FINISHED
FLOOR AS INDICATED
0213
DRAWING SCALE:
NONE
SHEET NO:
A1.2
ABBREVIATIONS
A
WALL-MOUNTED OR FURNITURE PANEL-MOUNTED
DUPLEX POWER RECEPTACLE
PARTITION TYPE A, TO 6 INCHES ABOVE CEILING
B
WALL-MOUNTED QUADRAPLEX POWER RECEPTACLE
PARTITION TYPE 'B', DEMISING TO SLAB ABOVE
WALL-MOUNTED DUPLEX RECEPTACLE, DEDICATED
CIRCUIT
C
PARTITION TYPE 'C', FURRING TYPE, 6 INCHES ABOVE
CEILING
WALL-MOUNTED GROUND FAULT CIRCUIT
INTERUPTER DUPLEX
GFI
4
COLUMN TARGET
OFFICE
1750
ROOM NUMBER TARGET
1750
A 1
B
PUSH-BUTTON DOOR RELEASE
44"
DOOR TARGET
DOOR NUMBER
HARDWARE SET
DOOR TYPE
1
A9
ELEVATION TARGET
DRAWING NUMBER
SHEET NUMBER
1
A11
SECTION TARGET
DRAWING NUMBER
SHEET NUMBER
2
A9
DETAIL TARGET
DRAWING NUMBER
SHEET NUMBER
4
MOUNTING HEIGHT IN INCHES ABOVE FINISHED
FLOOR
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
WALL-MOUNTED TELEPHONE AT 48" TO TOP OF
TELEPHONE
W
MILLWORK ITEM
A9
WALL-MOUNTED KEY CARD DEVICE
KEYNOTE TARGET
1
2
K
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
WALL OR FURNITURE PANEL-MOUNTED TELE-DATA
RECEPTACLE. GC TO PROVIDE CONDUIT AND PULL
STRING.
FLOOR-MOUNTED POKE-THROUGH WITH POWER AND
TELE-DATA DEVICES. FLUSH DEVICE.
3
T
FLOOR-MOUNTED TELE-DATA AND POWER FEEDS TO
FURNITURE PANEL (NOT USED)
P
CONTROL
JOINT
TV
TELEVISION RECEPTACLE W/ CABLE TO BUILDING
SOURCE
FINISH SYMBOLS
WC
1
WALL FINISH TARGET
WC - WALLCOVERING
P - PAINT
CT - CERAMIC TILE
GL - GLASS
GT - GLASS TILE
MW - MILLWORK PANEL
CPT
1
FLOOR FINISH TARGET
CPT - CARPET
VCT - VINYL COMPOSITION TILE
CER - CERAMIC TILE
RBR - RUBBER FLOORING
TZT - TERRAZZO TILE
EX - EXISTING TO REMAIN
CPT
1
FLOORING TRANSITION TARGETS
1
VCT
LIGHT SWITCH
CARD READER LOCATION
THERMOSTAT (NEVER DIRECTLY ABOVE LIGHT SWITCHES)
-
WALL MOUNTED PHONE TO BE MOUNTED WITH TOP OF
PHONE AT APPLICABLE REACH HEIGHT AS PER IAC 400.310v
NO.
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
3'-6"
CONTROL JOINT AT PARTITION OR SOFFIT
CJ
SIMPLEX POWER RECEPTACLE
4'-6"
WINDOW MULLION CENTERLINE
EQUIPMENT TARGET
4'-0"
M
EQ
3
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
1'-3"
CENTERLINE
WALL-MOUNTED TELE-DATA AND POWER FEEDS TO
FURNITURE PANEL
FRONT REACH*
CL
T
P
4'-0"
ACOUSTICAL
ADJUSTABLE
ALUMINUM
APPROXIMATE
ARCHITECTURAL
BOARD
BUILDING
BLOCK
BLOCKING
BOTTOM
CABINET
CEMENT
CERAMIC
CORNER GUARD
CONTROL JOINT
CENTERLINE
CEILING
CLEAR
CASED OPENING
COLUMN
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUOUS
COUNTER
CENTER
DOUBLE
DETAIL
DIAMETER
DIMENSION
DOWN
DOOR OPENING
DOOR
DRAWER
DRAWING
EAST
EACH
ELEVATION
ELECTRICAL
ELEVATOR
EMERGENCY
ENCLOSURE
ELECTRICAL PANELBOARD
EQUAL
EQUIPMENT
ELECTRIC WATER COOLER
EXISTING
EXPANSION
EXTENSION
FIRE ALARM
FLOOR DRAIN
FIRE EXTINGUISHER
FIRE EXTINQUISHER CABINET
FIRE HOSE CABINET
FINISH
FLOOR
FLUORESCENT
FIREPROOF
FULL SIZE
FOOT OR FEET
FURRING
GALVANIZED
GRAB BAR
GLASS
GROUND
GYPSUM
GYPSUM BOARD
HARDWOOD
HARDWARE
HOLLOW METAL
HORIZONTAL
HOUR
HEIGHT
INSULATION
INTERIOR
JOINT
LAMINATE
LAVATORY
LOCKER
MAXIMUM
MEMBRANE
METAL
MANUFACTURER
MINIMUM
MIRROR
MISCELLANEOUS
MASONRY OPENING
MOUNTED
NORTH
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
ON CENTER
OPENING
OPPOSITE
PLATE
PLASTIC LAMINATE
PLASTER
PLYWOOD
PAIR
POINT
PARTITION
QUARRY TILE
RADIUS
ROOF DRAIN
REFERENCE
REFRIGERATOR
REINFORCED
REQUIRED
RESILIENT
ROOM
ROUGH OPENING
SOUTH
SOLID CORE
SCHEDULE
SOLID SURFACE
SECTION
SHELF
SHEET
SIMILAR
SPECIFICATION
SQUARE
STAINLESS STEEL
STANDARD
STEEL
STRUCTURAL
SUSPENDED
SYMMETRICAL
TREAD
TO MATCH EXISTING
TOWEL BAR
TELEPHONE
TERRAZZO
TONGUE & GROOVE
THICK
TELEVISION
TYPICAL
UNFINISHED
UNLESS NOTED OTHERWISE
VERTICAL
VESTIBULE
WEST
WITH
WATER CLOSET
WOOD
WITHOUT
WATERPROOF
WAINSCOT
WEIGHT
ELECTRICAL SYMBOLS
SIDE REACH*
ACOUS.
ADJ.
AL.
APPROX.
ARCH.
BD.
BLDG.
BLK.
BLKG.
BOT.
CAB.
CEM.
CER.
C.G.
C.J.
CL
CLG.
CLR.
C.O.
COL.
CONC.
CONN.
CONSTR.
CONT.
CNTR.
CTR.
DBL.
DTL.
DIA.
DIM.
DN.
D.O.
DR.
DWR.
DWG.
E.
EA.
EL.
ELEC.
ELEV.
EMER.
ENCL.
E.P.
EQ.
EQPT.
E.W.C.
EXIST.
EXPAN.
EXT.
F.A.
F.D.
F.E.
F.E.C.
F.H.C.
FIN.
FL.
FLUOR.
F.P.
F.S.
FT.
FURR.
GALV.
G.B.
GL.
GND.
GYP.
GYP.BD.
HDWD.
HDWR.
H.M.
HORIZ.
HR.
HT.
INSUL.
INT.
JT.
LAM.
LAV.
LKR.
MAX.
MEMB.
MTL.
MFR.
MIN.
MIR.
MISC.
M.O.
MTD.
N.
N.I.C.
NO.
NOM.
N.T.S.
O.C.
OPNG.
OPP.
PL.
P. LAM.
PLAS.
PLYWD.
PR.
PT.
PTN
Q.T.
R.
R.D.
REF.
REFR.
REINF.
REQ.
RESIL.
RM.
R.O.
S.
S.C.
SCHED.
SD. S
SECT.
SH.
SHT.
SIM.
SPEC.
SQ.
S.S.
STD.
STL.
STRL.
SUSP.
SYM
TRD.
T.M.E.
T.B.
TELE.
TZ.
T.& G.
THK.
T.V.
TYP.
UNF.
U.N.O.
VERT.
VEST.
W.
W/
W.C.
WD.
W/O
WP.
WSCT.
WT.
ARCHITECTURE SYMBOLS
4'-6"
MATERIAL SYMBOLS
LEGEND
*ALL CONTROLS AND OPERATING MECHANISMS TO FALL WITHIN
FRONT AND SIDE REACH RANGES AS PER IAC 400.310r
1
ELEVATION @ TYPICAL DEVICE MOUNTING HEIGHTS
PROJECT NUMBER:
SCALE:
DRAWING SCALE:
3"=1'-0"
0213
AS NOTED
SHEET NO:
A2
C2
B1
5
GARNETT ARCHITECTS, LLC
6
ARCHITECTURE . PLANNING . INTERIOR DESIGN
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
4
GENERAL NOTES
A. ARCHITECTURAL ITEMS INDICATED WITH A DOTTED LINE
SHALL BE REMOVED. ARCHITECTURAL ITEMS INDICATED
WITH FILLED WALLS AND SOLID LINES SHALL REMAIN. SEE
SHEET A2 FOR LEGEND.
6
B. THE G.C. SHALL VERIFY EXISTING FIELD CONDITIONS.
CONFLICTS OR DISCREPANCIES SHALL BE REPORTED TO
THE ARCHITECT BEFORE PROCEEDING WITH WORK IN
QUESTION. NO CHANGE ORDER WILL BE APPROVED DUE TO
FIELD CONDITIONS THAT ARE EVIDENT PRIOR TO
DEMOLITION.
1
C. ARCHITECTURE TO REMAIN SHALL BE PROTECTED FROM
DAMAGE. ANY DAMAGE SHALL BE REPAIRED AT NO
ADDITIONAL COST TO THE TENANT.
3
D. SALVAGE LIFE SAFETY DEVICES, FIRE EXTINGUISHERS &
CABINETS FOR REUSE.
6
E. SALVAGE DOORS, FRAMES, SIDELIGHTS AND HARDWARE
FOR REUSE. CATALOG SALVAGED ITEMS FOR REUSE.
7
4
4
F. REMOVE ELECTRICAL OUTLETS AND DEVICES AS
INDICATED AND ON PARTITIONS/WALLS TO BE DEMOLISHED.
G. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL
DEMOLITION INFORMATION.
3
H, REFINISH EXISTING DRYWALL TO REMAIN.
KEYNOTES
1
3
1. REMOVE EXISTING DRYWALL AND FURRING. PROTECT
EXISTING MASONRY WALL DURING CONSTRUCTION.
2. REMOVE ELECTRICAL DEVICE AND OUTLETS AS
INDICATED ON EXISTING PARTITIONS TO REMAIN.
3
3. REMOVE ALL UNUSED, NONESSENTIAL CEILING ELEMENTS
INCLUDING BUT NOT LIMITED TO DUCTWORK, CONDUIT, AND
PIPES FROM THE PROPOSED OPEN CEILING AREA. REFER
TO SHEET A5 FOR PROPOSED AREA.
6
4. REMOVE EXISTING DRYWALL FROM COLUMNS, TYPICAL.
2
5. REMOVE EXISTING DEVICES AND CONDUIT FROM
COLUMNS, TYPICAL.
3
6. SALVAGE EXISTING DOORS, FRAMES, AND HARDWARE.
COORDINATE STORAGE WITH LANDLORD.
5
5
2
3
3
1
NO.
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
1
3
2
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
1
8TH FLOOR
DEMOLITION PLAN
A
B
C
D
E
F
PROJECT NUMBER:
NORTH
SHEET NO:
0213
DRAWING SCALE:
1/4" = 1'-0"
0
1'
2'
4'
8'
A3
C2
B1
SERVER/
STORAGE
813
CAFE
814
OFFICE
812
5
1
A9.1
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
M
7'-11"
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
4
B
2'-0"
7'-11"
CLOSET
800.1
6'-5"
RECEPTION
800
1
GENERAL NOTES
A. ALL PARTITIONS SHALL BE TYPE "A" UNLESS NOTED
OTHERWISE. SEE SHEET A10 FOR DETAILS.
A
B. GENERAL CONTRACTOR IS TO NOTIFY ARCHITECT WHEN
PARTITION LAYOUT MAY BE REVIEWED BEFORE PLACEMENT
OF METAL RUNNERS AND STUDS.
C. ALL PARTITIONS SHALL RECEIVE PAINT P-1 AND WALL
BASE B-1, UNLESS NOTED OTHERWISE.
8'-2"
22'-10"
8'-2"
3
A9.2
2
A9.1
CORRIDOR
811
C
A
4'-5"
C
2
A9.2
4
M1
19'-7"
11'-7"
8'-8"
5
8'-8"
14'-7"
B
4'-0"
D1
B
F. ALL HORIZONTAL SOFFIT PLANES ARE TO BE PAINTED
WHITE, UNLESS NOTED OTHERWISE. VERTICAL PLANES ARE
TO MATCH ADJACENT WALL SURFACES, UNLESS NOTED
OTHERWISE REFER TO ELEVATIONS FOR ADDITIONAL
INFORMATION.
12'-9"
OFFICE
810
6'-6"
G. FINISH TARGETS ARE FOR GENERAL INFORMATION. FOR
EXACT LOCATIONS OF FINISHES SEE ELEVATIONS,
SCHEDULES AND DETAILS.
3
B
1'-6"
1'-6"
4'-0"
A9
2'-0"
D1
B
10'-0"
8'-10"
E. THE G.C. SHALL PREPARE WALL, FLOOR AND CEILING
SURFACES AS REQUIRED AND RECOMMENDED BY
MANUFACTURER TO RECEIVE NEW FINISHES AS INDICATED
ON PLAN, INCLUDING FLOOR PREP.
C
3'-6"
25'-8"
C
11'-4"
A1
3
A9.1
D. ALL FLOORING SHALL BE CPT-1, UNLESS NOTED
OTHERWISE. VINYL BASE SHALL BE STRAIGHT TYPE AT
CARPET AND COVE TYPE AT VCT. DO NOT INSTALL WALL
BASE TO MILLWORK.
B
C
H. FLOORING TRANSITIONS AT DOOR OPENINGS SHALL
OCCUR AT THE DOOR CENTERLINE. SEE FINISH SPECS FOR
COLOR. SEE FLOOR FINISH TRANSITION DETAILS AT SHEET
A16.
7'-8"
4'-5"
FEC
M
4'-5"
4'-3"
1'-6"
2'-0"
OFFICE
809
J. FIRE EXTINGUISHER, FIRE HOSE CABINETS, AND ACCESS
PANELS SHALL BE PAINTED TO MATCH ADJACENT WALL
COLOR IN ALKYD ENAMEL PAINT.
DO NOT PAINT METAL CABINETS WITH LATEX WALL PAINT.
10'-1"
4
A9.1
B
B
1
A9.2
5'-4"
E
K. FLOORING MATERIAL SHALL BE INSTALLED UNDER NEW
MILLWORK.
5'-3"
BOARDROOM
801
L. REPAIR/ REFINIISH ALL DAMAGED EXISTING DRYWALL
CONDITIONS TO LIKE NEW CONDITION.
CORRIDOR
818
A1
BREAKOUT
AREA
815
COPY
AREA
816
M. FUR OUT ALL EXISTING COLUMNS. PROVIDE DETAIL TYPE
"D" ON SHEET A10.
KEYNOTES
8'-0"
6'-11"
B
1. PROVIDE COAT CLOSET MILLWORK PER DETAIL 1/ A11.
M
MIN
39'-1"
5
A9.1
2
OPEN
OFFICE
817
M
4'-0"
A1
7'-8"
26'-6"
OFFICE
808
B
18'-5"
B
10'-4"
11'-7"
13'-11"
B
B
B
11'-5"
11'-10"
11'-7"
14'-5"
-
E
NO.
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
1
8TH FLOOR
ARCHITECTURE PLAN
A
B
802
OFFICE
803
OFFICE
C
804
OFFICE
805
OFFICE
D
806
OFFICE
E
807
OFFICE
F
PROJECT NUMBER:
NORTH
SHEET NO:
0213
DRAWING SCALE:
1/4" = 1'-0"
0
1'
2'
4'
8'
A4
C2
B1
SERVER/
STORAGE
813
CAFE
814
OFFICE
812
5
X
A10
EXISTING
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
8'-6"
F9
F9
RECEPTION
800
F9
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
4
E
OPEN CEILING
F1
CLOSET
800.1
GENERAL NOTES
A. CEILING HEIGHT 8'-6" AFF U.N.O.
B. THIS DRAWING INDICATES THE LOCATION OF FIXTURES
AND SWITCHES. REFER TO ENGINEER'S DRAWINGS FOR
CIRCUIT DESIGN, SPECIFICATIONS AND SCHEDULES.
F1
F10
C. SEE ENGINEERING DRAWINGS FOR LOCATIONS OF EXIT
SIGNS AND EMERGENCY FIXTURES. PROVIDE EXIT SIGNS AS
REQUIRED BY THE LOCAL FIRE OFFICIAL UPON REVIEW.
1
A10
1
CORRIDOR
811
D. TYPICAL CEILING TO BE CLG2 UNLESS NOTED OTHERWISE.
REFER TO CEILING SCHEDULE ON SHEET A1.2
F10
F5
E. G.C. SHALL REVIEW LOW-HANGING DUCTWORK AND
PIPING, ETC. TO CONFIRM CEILING RESTRICTIONS. ANY
CONFLICT OR INTERFERENCE SHALL BE BROUGHT TO THE
ARCHITECT'S ATTENTION FOR REVIEW.
F7
F8B
8'-6"
F8B
8'-6"
E
F8A
F2
F2
F2
F. MULTIPLE SWITCH LOCATIONS SHALL BE GROUPED
TOGETHER WITH A SINGLE COVER PLATE. SEE LEGEND
SHEET A2 FOR OUTLET & DEVICE MOUNTING HEIGHTS.
1
F2
F2
8'-6"
F5
F1
F1
F1
REFER TO SHEET A1.2 FOR ALL SYMBOLS AND SCHEDULES.
3
2
A10
F5
aD
KEYNOTES
bD
cD
BOARDROOM
801
F1
F8A
8'-6"
F2
OPEN CEILING
F1
G. ELECTRICAL DEVICES SHALL BE IVORY AND COVER
PLATES SHALL BE STAINLESS STEEL. SEE ENGINEERING
DRAWINGS FOR COLORS OF SPECIALTY DEVICES.
OFFICE
810
1
2
A10
3
A10
1. EXPOSED STRUCTURE, MECHANICAL DUCTS AND
SPRINKLER PIPES SHALL RECEIVE PAINT P-1, FLAT FINISH.
SEE FINISH LEGEND ON SHEET A1.2. GC TO PROVIDE
APPROPRIATE COATING FOR EACH CEILING ELEMENT
INCLUDING, BUT NOT LIMITED TO DUCTWORK, PIPING, STEEL,
AND CONCRETE.
1
F4
F4
F4
OFFICE
809
F4
1
3
A10
8'-6"
b
b
F9
F9
8'-6"
F1
F1
F6
CORRIDOR
818
BREAKOUT
AREA
815
COPY
AREA
816
c F5
b
b
F9
F9
F12
F3
F3
F3
F3
F3
3
A10
b
b
F9
F3
F1
F1
2
OPEN
OFFICE
817
F9
F10
F9
1
F9
OPEN CEILING
F4
F4
F4
F4
9'-0"
F9
b
b
F9
OFFICE
808
F9
F9
F1
F1
F1
F1
F1
F1
F1
8'-6"
NO.
c F5
b
F9
a
b
E
ISSUED FOR BID AND PERMIT
DATE
REVISION
F9
F11
3
AXX
03/13/15
F1
F1
F1
F1
F1
4
A10
F1
4
A10
1
E
E
10'-0"
E
F1
E
E
E
E
E
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
E
1
8TH FLOOR
REFLECTED CEILING PLAN
A
B
802
OFFICE
803
OFFICE
C
804
OFFICE
805
OFFICE
D
806
OFFICE
E
807
OFFICE
F
PROJECT NUMBER:
NORTH
SHEET NO:
0213
DRAWING SCALE:
1/4" = 1'-0"
0
1'
2'
4'
8'
A5
C2
B1
SERVER/
STORAGE
813
CAFE
814
OFFICE
812
5
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
4
E
E
E
E
RECEPTION
800
GENERAL NOTES
10'-6"
CLOSET
800.1
E
A. THIS DRAWING INDICATES THE LOCATION OF FIXTURES,
DEVICES, AND EQUIPMENT. REFER TO ENGINEERING
DRAWINGS FOR CIRCUIT DESIGN, SPECIFICATIONS AND
SCHEDULES.
B. DIMENSIONS INDICATED SHALL BE TO THE CENTERLINE
OF ELECTRICAL OUTLET OR GROUP OF OUTLETS. SEE
LEGEND SHEET A2 FOR OUTLET & DEVICE MOUNTING
HEIGHTS.
13'-1"
1'-7"
4'-1"
CORRIDOR
811
3
C.
SYMBOL DENOTES AN EQUIPMENT TYPE. REFER TO
LEGEND SHEET A1.2 AND ENGINEERING DRAWINGS FOR
ADDITIONAL INFORMATION.
1'-6"
3'-6"
40"
GFI
10'-5"
40"
GFI
D. THE G.C. SHALL NOTIFY THE ARCHITECT WHEN LAYOUT
OF ELECTRICAL AND COMMUNICATION DEVICES BACKBOX
LOCATIONS ARE INSTALLED.
E. ELECTRICAL DEVICES SHALL BE GREY AND COVER
PLATES SHALL BE BRUSHED STAINLESS STEEL, UNLESS
NOTED OTHERWISE. SEE ENGINEERING DRAWINGS FOR
COLORS OF SPECIALTY DEVICES.
5
OFFICE
810
40"
KEYNOTES
1. WALL-MOUNTED POWER AND DATA FEED TO FURNITURE
PANELS.
3
40"
30"
2. PROVIDE POWER AND DATA CONNECTION TO FURNITURE
PANELS FOR EQUIPMENT IN COPY AREA.
72"
4
72"
BOARDROOM
801
FEC
3. PROVIDE FLUSH FLOOR CORE DEVICE WITH DUPLEX AND
TELE-DATA RECEPTACLES.
72"
OFFICE
809
4. PROVIDE BLOCKING FOR WALL MOUNTED TV. PROVIDE
CONNECTIVITY FROM TV TO TABLE. COORDINATE WITH
FURNITURE VENDOR AND AV CONSULTANT.
40"
5. REFER TO ENGINEERING DRAWINGS FOR SCOPE.
40"
40"
CORRIDOR
818
40"
BREAKOUT
AREA
815
4'-10"
COPY
AREA
816
40"
2'-2"
2
10'-0"
3
1
1
2
10'-5"
OPEN
OFFICE
817
3
OFFICE
808
13'-1"
-
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
4'-10"
4'-0"
4'-10"
3'-9"
4'-10"
3'-9"
6'-2"
NO.
3'-3"
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
1
8TH FLOOR
POWER & TELE PLAN
A
B
802
OFFICE
803
OFFICE
C
804
OFFICE
805
OFFICE
D
806
OFFICE
E
807
OFFICE
F
PROJECT NUMBER:
NORTH
SHEET NO:
0213
DRAWING SCALE:
1/4" = 1'-0"
0
1'
2'
4'
8'
A6
C2
B1
SERVER/
STORAGE
813
CAFE
814
OFFICE
812
5
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
4
RECEPTION
800
CLOSET
800.1
GENERAL NOTES
A. SEE LEGEND SHEET A2 FOR DESCRIPTION OF FINISH
TARGETS. SEE FINISH SPECIFICATIONS AT SHEETS A12
B. ALL PARTITIONS SHALL RECEIVE PAINT P-1 AND WALL
BASE B-1, UNLESS NOTED OTHERWISE.
C. ALL FLOORING SHALL BE CPT-1, UNLESS NOTED
OTHERWISE. VINYL BASE SHALL BE STRAIGHT TYPE AT
CARPET AND COVE TYPE AT VCT. DO NOT INSTALL WALL
BASE TO MILLWORK.
WC
1
2
CORRIDOR
811
D. THE G.C. SHALL PREPARE WALL, FLOOR AND CEILING
SURFACES AS REQUIRED AND RECOMMENDED BY
MANUFACTURER TO RECEIVE NEW FINISHES AS INDICATED
ON PLAN, INCLUDING FLOOR PREP.
WD
1
E. ALL HORIZONTAL SOFFIT PLANES ARE TO BE PAINTED
WHITE, UNLESS NOTED OTHERWISE. VERTICAL PLANES ARE
TO MATCH ADJACENT WALL SURFACES, UNLESS NOTED
OTHERWISE REFER TO ELEVATIONS FOR ADDITIONAL
INFORMATION.
2
VT
2
VT
1
CPT
1
CPT
1
P
2
2
F. FINISH TARGETS ARE FOR GENERAL INFORMATION. FOR
EXACT LOCATIONS OF FINISHES SEE ELEVATIONS,
SCHEDULES AND DETAILS.
OFFICE
810
B
2
G. FLOORING TRANSITIONS AT DOOR OPENINGS SHALL
OCCUR AT THE DOOR CENTERLINE. SEE FINISH SPECS FOR
COLOR. SEE FLOOR FINISH TRANSITION DETAILS AT SHEET
A10.
3
2
FEC
BOARDROOM
801
P
2
B
2
P
2
B
2
H. FIRE EXTINGUISHER, FIRE HOSE CABINETS, AND ACCESS
PANELS SHALL BE PAINTED TO MATCH ADJACENT WALL
COLOR IN ALKYD ENAMEL PAINT.
DO NOT PAINT METAL CABINETS WITH LATEX WALL PAINT.
OFFICE
809
J. FLOORING MATERIAL SHALL BE INSTALLED UNDER NEW
MILLWORK.
CPT
2
CPT
1
KEYNOTES
WC
2
1
CORRIDOR
818
BREAKOUT
AREA
815
CPT
1
WC
2
1. PROVIDE WALL GRAPHIC ARTWORK WALL COVERING ,
WC-3. INCLUDE HIGH RESOLUTION PHOTOGRAPHIC IMAGE
AND ARTWORK LICENSING FEES. INCLUDE ONE MOCKUP FOR
COORDINATING IMAGE WITH ARCHITECT AND CLIENT. REFER
TO SCHEDULE ON SHEET A1.2 FOR ADDITIONAL
INFORMATION.
COPY
AREA
816
P
2
CPT
2
CPT
2
B
2
2. CONTINUE SPECIFIED FLOOR FINISH UNDER ALL
MILLWORK.
1
P
2
2
OPEN
OFFICE
817
B
2
OFFICE
808
CPT
1
1
P
2
CPT
1
CPT
1
B
2
P
2
P
2
B
2
B
2
CPT
1
CPT
1
P
2
P
2
B
2
B
2
P
2
CPT
1
NO.
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
B
2
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
1
8TH FLOOR
FINISH PLAN
A
B
802
OFFICE
803
OFFICE
C
804
OFFICE
805
OFFICE
D
806
OFFICE
E
807
OFFICE
F
PROJECT NUMBER:
NORTH
SHEET NO:
0213
DRAWING SCALE:
1/4" = 1'-0"
0
1'
2'
4'
8'
A7
C2
B1
CAFE
814
SERVER/
STORAGE
813
OFFICE
812
5
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
4
RECEPTION
800
CLOSET
800.1
GENERAL NOTES
A. FURNITURE PLAN IS FOR INFORMATION ONLY. G.C. SHALL
COORDINATE INSTALLATION OF FURNITURE WITH OWNER'S
VENDOR.
B. TRAVEL DISTANCE IS REPRESENTED BY DASHED LINE AND
TAKEN FROM THE FURTHEST POINT IN THE ROOM TO THE
EXIT DOOR.
CORRIDOR
811
OFFICE
810
3
FEC
BOARDROOM
801
OFFICE
809
FLAG
AREA
CORRIDOR
818
BREAKOUT
AREA
815
COPY
AREA
816
2
OPEN
OFFICE
817
99 FT
76 FT
OFFICE
808
NO.
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
1
8TH FLOOR
FURNITURE PLAN
A
B
802
OFFICE
803
OFFICE
C
804
OFFICE
805
OFFICE
D
806
OFFICE
E
807
OFFICE
F
PROJECT NUMBER:
NORTH
SHEET NO:
0213
DRAWING SCALE:
1/4" = 1'-0"
0
1'
2'
4'
8'
A8
LINE OF EXISTING
STRUCTURE
LOGO BY OTHERS
LINE OF EXISTING
STRUCTURE
SCHEDULED DOOR
AND FRAME
1/4" CLEAR TEMPERED
GLASS SIDELIGHTS
LINIE OF SOFFIT
SCHEDULED DOOR AND
FRAME
LINE OF FINISHED
CEILING
12'-6" VIF
8'-6"
8'-6"
SCHEDULED WALL
BASE
8'-6"
1/4" CLEAR
TEMPERED GLASS,
GL-1
OPEN
12'-6"
SCHEDULED DOOR &
FRAME
LINE OF FINISHED
FLOOR
8
PLASTIC LAMINATE
CREDENZA WITH CUSTOM
SEAT CUSHION PROVIDED
BY OTHERS.
PL-1 COUNTER TOP AND
BASE CABINETS
SCHEDULED WALL BASE
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
LINE OF FINISHED
FLOOR
6'-0"
EQ
EQ
EQ
15'-6"
EQ
2'-5"
2'-5"
LINE OF FINISHED FLOOR
EQ
8'-2"
EQ
4"
GENERAL NOTES
EQ
A. ALL VERTICAL MILLWORK PULLS WHERE INDICATED ON
DRAWINGS TO BE:
OVERSIZED BAR PULL
EPCO, ENGINEERED PRODUCTS CO.,
BP192-SS, STAINLESS STEEL
C-C7.65, OVERALL LENGTH 9.84.
B. ALL HORIZONTAL MILLWORK PULLS WHERE INDICATED ON
DRAWINGS TO BE:
OVERSIZED BAR PULL
EPCO, ENGINEERED PRODUCTS CO.,
BP096-SS, STAINLESS STEEL
C-C 3.78, OVERALL LENGTH 6.14.
LINE EXISTING
STRUCTURE
SCHEDULED DOOR AND
FRAME
2
6'-0"
VIF
8'-6"
3'-0"
1'-7"
1/4"
TYP
SCHEDULED WALL BASE
LINE OF FINISHED
FLOOR
2'-5"
2'-0"
PLASTIC LAMINATE
CREDENZA.
PL-1 COUNTER TOP AND
BASE CABINETS
9'-9"
EQ
8
VIF
EQ
1/4" CLEAR TEMPERED
GLASS SIDELIGHTS
12'-6"
PROVIDE BLOCKING FOR
WALL MOUNTED TV. TV
PROVIDED BY OWNER
12'-6"
EQ
EQ
EQ
8'-6"
C. RECEPTION AND BOARDROOM MILLWORK PULLS TO BE
ROUTED FINGER PULLS AS INDICATED IN DETAILS.
3
2'-9"
3'-0"
3'-6"
1/4"
4'-6"
1/4"
4'-9"
1/4"
3'-11"
4'-6"
1/4"
4'-9"
1/4"
4'-6"
1/4"
6'-9"
39'-1"
8
3/4"
2'-1"
3/4"
10'-9"
EQ
EQ
EQ
EQ
2'-6"
EQ
NO.
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
10
12
11
2'-10"
3'-6"
9
2'-2"
6
4'-5"
5'-2"
3/4"
2'-1"
EQ
3/4" 3'-0" CLEAR
EQ
4'-5"
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
EQ
20" CLEAR
1'-8"
3'-3"
ELEVATIONS
19'-7"
PROJECT NUMBER:
SHEET NO:
0213
DRAWING SCALE:
3/8" = 1'-0"
0 6" 1'
3'
5'
A9.1
5'-7"
3'-0"
2'-0"
1'-0"
3'-0"
8'-1"
6"
2'-6"
3
8'-7"
2'-9"
7'-6"
5
5'-7"
GARNETT ARCHITECTS, LLC
3'-0"
ARCHITECTURE . PLANNING . INTERIOR DESIGN
1'-1"
8'-6"
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
3'-2"
3'-6"
4"
2'-5"
2'-3"
3'-6"
GENERAL NOTES
6'-6"
A. ALL VERTICAL MILLWORK PULLS WHERE INDICATED ON
DRAWINGS TO BE:
OVERSIZED BAR PULL
EPCO, ENGINEERED PRODUCTS CO.,
BP192-SS, STAINLESS STEEL
C-C7.65, OVERALL LENGTH 9.84.
8'-7"
5'-1"
B. ALL HORIZONTAL MILLWORK PULLS WHERE INDICATED ON
DRAWINGS TO BE:
6"
3'-6"
OVERSIZED BAR PULL
EPCO, ENGINEERED PRODUCTS CO.,
BP096-SS, STAINLESS STEEL
C-C 3.78, OVERALL LENGTH 6.14.
4"
2'-5"
3'-2"
1'-1"
3'-0"
1 1/2"
7'-10"
C. RECEPTION AND BOARDROOM MILLWORK PULLS TO BE
ROUTED FINGER PULLS AS INDICATED IN DETAILS.
1 1/2"
SOLID SURFACE
TRANSACTION TOP, SD-2
SOLID SURFACE TRANSACTION TOP,
SD-2
SOLID SURFACE TRANSACTION TOP,
SD-2
PLASTIC LAMINATE, PL-X
PLASTIC LAMINATE, PL-X
SOLID SURFACE WORKSURFACE,
SD-1
SOLID SURFACE WORKSURFACE,
SD-1
FURNITURE BY OTHERS
PLASTIC LAMINATE, PL-1
PLASTIC LAMINATE, PL-1
PLASTIC LAMINATE, PL-X
SOLID SURFACE
WORKSURFACE, SD-1
FURNITURE BY OTHERS
2'-0"
3'-2"
3'-6"
1'-0"
4"
OPEN
6"
X
3'-0"
RIGHT ELEV. @ RECEPTION DESK
SCALE:
3/8"=1'-0"
NO.
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
ELEVATIONS
PROJECT NUMBER:
SHEET NO:
0213
DRAWING SCALE:
3/8" = 1'-0"
0 6" 1'
3'
5'
A9.2
1 5/8" SLOTTED DEFLECTION
TRACK WITH SLIP JOINT FOR
MOVEMENT OF STRUCTURE
FIRESTOP SEALANT
PARTITION TYPE "A1"
CONTINUE DRYWALL
UP TO DECK AT OPEN
CEILING
2-1/2" SLOTTED DEFLECTION
TRACK WITH SLIP JOINT FOR
MOVEMENT OF STRUCTURE
2 1/2" SLOTTED DEFLECTION
TRACK WITH SLIP JOINT FOR
MOVEMENT OF STRUCTURE
6"
6"
6"
TYPE "A1" REFER
TO MECHANICAL
DRAWINGS FOR
RETURN AIR GRILL
SIZE AND LOCATION
PARTITION TYPE "D1"
CONTINUE DRYWALL AND
FRAMING UP TO UNDERSIDE
OF DECK IN AREAS WITH
OPEN CEILING
PARTITION TYPE "C1"
CONTINUE DRYWALL AND
FRAMING UP TO UNDERSIDE
OF DECK IN AREAS WITH
OPEN CEILING
SOUND BATT TO 24" EA. SIDE OF
WALL (ONLY AS KEYNOTED ON PLAN)
TYPE "A1" REFER TO
REFLECTED CEILING
PLAN FOR LOCATIONS
WITH OPEN CEILING
SCHEDULED CEILING
SUSPENDED ACOUSTICAL TILE
CEILING
SCHEDULED CEILING
SCHEDULED TRIM
2-1/2" SOUND ATTENUATION
BLANKET
2-1/2" SOUND ATTENUATION BLANKET
SPECIFIED WALL BASE
SPECIFIED WALL BASE
2-1/2" METAL RUNNER
2 1/2" METAL RUNNER
EXISTING FLOOR SLAB
EXISTING FLOOR SLAB
A1
2 1/2" STUD TENANT PARTITION
A SCALE: 3"=1'-0"
3 3/4"
3"=1'-0"
EXISTING CONCRETE COLUMN OF
PARTITION
GARNETT ARCHITECTS, LLC
ONE LAYER 5/8" GYPSUM BOARD
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
SPECIFIED WALL BASE
SCHEDULED WALL BASE
1 5/8" METAL RUNNER
EXISTING FLOOR SLAB
EXISTING FLOOR SLAB
FRAMING SCHEDULE
D1
PARTITION TYPE 'E'
D SCALE: 3"=1'-0"
2 1/4"
2 1/2" STUD DEMISING
SCALE:
5/8" GYPSUM BOARD
C1
FURRING PARTITION
C SCALE: 3"=1'-0"
3 3/4"
B
1 5/8" METAL STUDS
SEE FRAMING SCHEDULE FOR
SPACING AND GAUGE
ARCHITECTURE . PLANNING . INTERIOR DESIGN
2 1/2" METAL STUDS, SEE FRAMING
SCHEDULE FOR SPACING AND
GAUGE
ONE LAYER 5/8" GYPSUM BOARD
EACH SIDE
7/8" METAL FURRING CHANNEL
2-1/2" SOUND ATTENUATION BLANKET
(AT PLUMBING LOCATIONS ONLY
ONE LAYER 5/8" GYPSUM BOARD
EACH SIDE
8'-6"
SEE RCP
2-1/2" METAL STUDS, SEE FRAMING
SCHEDULE FOR SPACING AND
GAUGE
SCHEDULED CEILING
1 1/2"
Stud Depth
Gauge
25
20
STRUCTURE ABOVE
2 1/2" SLOTTED DEFLECTION
TRACK WITH SLIP JOINT FOR
MOVEMENT OF STRUCTURE
ACOUSTICAL SEALANT
25
EXISTING BUILDING SLAB
OR DECK
2 1/2" METAL TRACK
ATTACHED TO STRUCTURE
2 1/2" METAL FRAMING
ADDITIONAL
LAYER OF
DRYWALL ON
BOARDROOM
SIDE
6"
2 1/2" SOUND ATTENUATION BLANKET
8'-0" U.N.O.
ONE LAYER 5/8" GYPSUM BOARD EACH
SIDE
EXISTING STRUCTURAL
DECK
20
5/8" GYPSUM BOARD OVER
2-1/2" METAL STUDS
SCHEDULED CEILING
25
6"
1-1/2" ALUMINUM FRAME BY WILSON
PARTITIONS OR EQUAL
20
8'-6"
8'-6"
SPECIFIED WALL BASE
3 3/4"
FINISHED FLOORING
2 1/2" METAL RUNNER
ALIGN
1 1/2"
METAL CORNER BEAD NO.
103, TYPICAL
SEE PLAN
SCALE:
SCHEDULED CEILING AND
TRIM
3"=1'-0"
8'-4"
24
7'-11"
12
9'-11"
16
9'-2"
24
8'-3"
12
11'-11"
16
11'-3"
24
10'-7"
12
13'-2"
16
12'-1"
24
10'-9"
12
15'-4"
16
14'-4"
24
13'-5"
12
17'-1"
16
15'-8"
24
14'-0"
12
22'-1"
16
19'-9"
24
16'-9"
12
25'-6"
16
23'-2"
24
20-3"
6"
5/8" GYPSUM BOARD
4 3/8"
E
25
SEE PLAN
SPECIFIED FINISHED FLOOR
BOARD ROOM DEMISING WALL
16
METAL CORNER BEAD
FIRE-RESISTANT TREATED WOOD
BLOCKING
M1
OFFICE STOREFRONT
M SCALE: 3"=1'-0"
8'-10"
3-5/8"
1/4" CLEAR TEMPERED GLASS
2 1/2" METAL STUDS, SEE FRAMING
SCHEDULE FOR SPACING AND GAUGE
12
2-1/2"
ONE LAYER 5/8" GYPSUM BOARD
EACH SIDE TO 6" BELOW STRUCTURE
FOR AIR RETURN
1 1/2"
2-1/2" SOUND ATTENUATION BLANKET
Maximum Height
1-5/8"
PARTITION TYPE "M1"
CONTINUE DRYWALL AND
FRAMING UP TO UNDERSIDE
OF DECK IN AREAS WITH
OPEN CEILING
ACOUSTIC SEALANT
Spacing
(Inches)
20
SCHEDULED PARTITION
1
SECTION @ DRYWALL SOFFIT
SCALE:
3"=1'-0"
2
CEILING TRANSITION
SCALE:
3"=1'-0"
10'-0" V.I.F.
DRYWALL SOFFIT
SCHEDULED CARPET
LATEX 14" PER FOOT MAX.
NOTE: TOP OF CARPET TO BE 1 4"
ABOVE DIVIDER STRIP.
ALIGN
5/8" GYPSUM BOARD OVER
2-1/2" METAL STUDS
DOOR, WHERE SPECIFIED
1
SCHEDULED CARPET FLOORING
8"
ZINC DIVIDER STRIP
-
EXISTING FLOOR SLAB
NO.
UNDERCUT
AS REQ'D
PAINTED STRUCTURE ABOVE (NOT
SHOWN)
8'-6"
ISSUED FOR BID AND PERMIT
DATE
REVISION
SCHEDULED WOOD FLOOR
6"
4" NOM.
SCHLUTER RENO-U ALUMINUM
TRANSITION STRIP
03/13/15
8'-6"
SCHEDULED RESILIENT FLOORING
3-3/4"
4" NOMINAL SPECIALTY CEILING
SUSPENSION TRIM. PROVIDE
PREFABRICATED CORNERS.
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
ALIGN
SCHEDULED CEILING AND
TRIM
SCHEDULED CEILING
PARTITION TYPES &
DETAILS
CENTERLINE OF SCHEDULED
DOOR AND SCHLUTER STRIP
METAL CORNER BEAD
EXISTING EXTERIOR
WINDOW
3
CEILING EDGE @ OPEN OFFICE
SCALE:
3"=1'-0"
4
WINDOW TRANSITION
SCALE:
3"=1'-0"
PROJECT NUMBER:
5
CARPET / VCT TRANSITION
SCALE:
3"=1'-0"
6
CARPET TO WOOD TRANSITION
DRAWING SCALE:
SCALE:
AS NOTED
3"=1'-0"
0213
SHEET NO:
A10
6"
1'-3"
1 1/2"
WHITE 3/4" MELAMINE SHELF
3/4"
SEE PLAN
3/4"
POPLAR CLEATS. GC TO
PROVIDE IN-WALL BLOCKING
TO SUPPORT CABINETS.
2'-1" OPENING
CHROMED STEEL COAT
ROD W/ THREADED END
SUPPORTS
FIRE EXTINGUISHER AND
CABINET POTTER ROEMER
#1702 OR AS SPECIFIED ON
FIRE PROTECTION
DRAWINGS
4'-0" A.F.F. @ ACCESSIBLE
1 1/2" X 1 1/2" CONTINUOUS
ANGLE SUPPORT AT
WALLS. PAINT TO MATCH
PARTITION.
3/4" THICK MELAMINE
TRAPEZE WITH HOLE TO
SUPPORT LOWER COAT
ROD FOR HANDICAP
ACCESSIBILITY (1)-30"
SECTION
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
SPECIFIED WC-3, TRIM
TIGHT TO EDGE PROFILE
FRY REGLET PROTRUDING
EDGE PROFILE
DRMPET-100, CLEAR
ANODIZED ALUMINUM
1'-9"
SPECIFIED PULLS
FIRE EXTINGUISHER CABINET DETAIL
SCALE:
3
3"=1'-0"
BOARDROOM WALLCOVERING DETAIL
SCALE:
3"=1'-0"
2'-0"
SPECIFIED PARTITION
14"
SOLID SURFACE
COUNTERTOP
1 1/2"
POPLAR CLEATS. MILLWORKER
TO PROVIDE WALL BLOCKING
TO SUPPORT CABINETS.
1 1/2"
PLASTIC LAMINATE TOP W/ 3/4"
PLAS. LAM. RETURN AT ENDS
WHITE MELAMINE INTEROR
PLAM DOOR WITH ROUTED
FINGER PULL AND
CUSHIONED SELF CLOSING
HINGES
1 1/2"
EQUAL
WHITE MELAMINE INTERIOR
WITH ADJUSTBLE SHELF
FIXED PLASTIC LAMINATE
SHELVES
PLASTIC LAMINATE
MICROWAVE OVEN SHELF
WHITE MELAMINE INTERIOR
3/4"
1'-1"
SCHEDULED EQUIPMENT
1 1/2"
3'-6"
WHITE MELAMINE
INTERIOR WITH
ADJUSTABLE SHELF
3/4"
2'-5"
EQUAL
2'-0"
FINISHED FLOOR
2'-11"
SCHEDULED UNDERCABINET
LIGHT FIXTURE BY GC
2'-1"
2'-1"
PLASTIC LAMINATE UPPER
CABINET
BAR PULL
EPCO, ENGINEERED PRODUCTS
CO., BP2565-SN, SATIN NICKEL,
C-C 10.08", OVERALL LENGTH
13.23"
1'-2"
2
3"=1'-0"
SEE ELEVATION
ARCHITECTURE . PLANNING . INTERIOR DESIGN
7'-9"
SECTION @ COAT ROD & HAT SHELF
SCALE:
GARNETT ARCHITECTS, LLC
PLASTIC LAMINATE UPPER
CABINET
SINGLE LAYER OF DRYWALL
AT RECESSED ART NICHE
FURRING WALL
5/8" GYPSUM BOARD OVER 2
1/2" METAL
STUD CONSTRUCTION
2'-6" A.F.F.
INTERMEDIATE
SUPPORTS TO BE
"STANLEY" NO. 7045
SHELF AND CLOSET
POLE BRACKET. PAINT
TO MATCH PARTITION.
BRACKETS TO BE 4'-0"
MAX. O.C.
WHITE MELAMINE INTERIOR
WITH ADJUSTABLE SHELF
1'-8"
5'-9" A.F.F.
TYP.
1
DRYWALL SOFFIT
ADJUSTABLE PLAM
SHELVES
PLASTIC LAMINATE TOE KICK
1'-1"
1-1/2" = 1'-0"
CAFE COUNTERTOP WITH OPEN SHELVING
SCALE:
1 1/2"=1'-0"
SPECIFIED FULL HEIGHT
BACKSPLASH
2'-1"
7
TYPICAL BASE CABINET
SCALE:
8
1-1/2" = 1'-0"
SCALE:
SPECIFIED FULL HEIGHT
BACKSPLASH
SPECIFIED FULL HEIGHT
BACKSPLASH
SOLID SURFACE
COUNTERTOP
SOLID SURFACE
COUNTERTOP
SOLID SURFACE
COUNTERTOP
2'-1"
2'-1"
SOLID SURFACE COUNTERTOP
3/4"
6"
3/4"
6"
PLASTIC LAMINATE CABINET
DOOR W/ QUIRK TO MATCH
DRAWER
FRONT. PROVIDE SELF-CLOSING
HINGES.
PLAM DRAWER WITH
HEAVY-DUTYDRAWER
GLIDES, TYPICAL
1 1/2"
HEAVY-DUTYDRAWER
GLIDES
1 1/2"
SCHEDULED UNDER-MOUNT
STAINLESS STEEL SINK,
STRAINER DRAIN AND
ACCESSIBLE FAUCET
1 1/2"=1'-0"
SPECIFIED FULL HEIGHT
BACKSPLASH
2'-1"
1 1/2"
SECTION @ MICROWAVE TOWER
SPECIFIED PULLS
SPECIFIED PULLS, TYPICAL
SPECIFIED PULLS, TYPICAL
PLAM QUARK TO MATCH
DRAWER FRONT
PLAM CABINET DOOR W/
SELF-CLOSING HINGES
AND CUSHION SILENCERS
PLAM TOE KICK
4"
4"
PLAM TOE KICK
03/03/15
ISSUED FOR ENGINEERING
DATE
REVISION
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
PLAM TOE KICK
MILLWORK DETAILS
4"
3/4" PLASTIC LAMINATE
INTERGRAL TOE KICK SCREWED
TO 18 GAUGE BRAKE-FORMED
STEEL SHEET. BEVEL SWINGING
EDGE FOR CLEARANCE.
1
NO.
PULL OUT TRASH/
RECYCLE BIN.
HAFELE US CARGO 21
502.74.852
WITH (2) 10.57 GALLON
TRASH BINS
502.74.900
2'-10"
3/4"
WHITE MELAMINE
INTERIOR
2'-10"
2'-0"
WHITE MELAMINE
INTERIOR WITH
ADJUSTABLE SHELF
4"
SCHEDULED WALL BASE
SEE ELEVATION
2'-10"
SPECIFIED PULL
SCHEDULED PARTITION
PLAM DRAWER WITH
HEAVY-DUTY DRAWER
GLIDES
3/4"
SCALE:
6
1 1/2"
SECTION @ UPPER CABINET
6"
5
4"
4" 1 1/2"
PLAM TOE KICK
PROJECT NUMBER:
9
ACCESSIBLE SINK CABINET
SCALE:
1 1/2"=1'-0"
10
TYPICAL BASE CABINET
SCALE:
1-1/2" = 1'-0"
11
TYPICAL BASE CABINET
SCALE:
1-1/2" = 1'-0"
12
TYPICAL BASE CABINET W/ TRASH
DRAWING SCALE:
SCALE:
AS NOTED
1-1/2" = 1'-0"
0213
SHEET NO:
A11
A1 = 2'-8"
3'-0"
1 1/2"
EQUAL
EQUAL
1 1/2"
1 1/2"
1 1/2"
6'-0"
EQ.
1 1/2"
1 1/2"
ALUMINUM FRAME
7
A12
ALUMINUM VERTICAL
MULLION. REFER TO
PLAN FOR LOCATION
WOOD VENEER SOLID
CORE DOOR (WD-2)
1/4" TEMPERED
CLEAR GLASS (GL-1)
5
A12
4'-0"
ALUMINUM FRAME
CONCEALED FRAME
8
A12
WOOD VENEER RAIL
AND STILE DOOR
(WD-2) WITH 41" GLASS
PANEL
1/4" TEMPERED
CLEAR GLASS (GL-1)
6
A12
5
A12
SOLID CORE WOOD
DOOR, PAINTED
8
A12
WOOD VENEER RAIL
AND STILE DOOR
(WD-2) WITH 41" GLASS
PANEL
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
1/4" TEMPERED
CLEAR GLASS (GL-1)
3'-4"
8
A12
3'-4"
6
A12
5
A12
6
A12
DOOR HARDWARE
5
A12
REFER TO SHEET A1.2 FOR DOOR HARDWARE SCHEDULE
B
DOOR W/ SIDELITE
SCALE:
C
3/8"=1'-0"
SCALE:
D
3/8"=1'-0"
ENTRY DOOR PAIR
SCALE:
PIVOT DOOR PAIR
E
3/8"=1'-0"
SCALE:
SEE PLAN
1 1/2"
3/8"=1'-0"
SEE PLAN
1 1/2"
SEE PLAN
1 1/2"
SEE PLAN
DOOR W/ SIDELITE
1/2"
1 1/2"
3'-4"
1 1/2"
ALUMINUM VERTICAL
MULLION
8'-0"
A3 = 8'-6"
8'-0"
7
A12
5
A12
A1A2 A3
TYPICAL DOOR
A SCALE: 3/8"=1'-0"
EQ.
SEE PLAN
ALUMINUM FRAME
TYPE "A2" 20
MINUTE RATED
WOOD VENEER
SOLID CORE DOOR
(WD-2
1 1/2"
3
A12
SEE PLAN
ALUMINUM FRAME
COAT HOOK
OFFICE SIDE ONLY
WOOD VENEER
SOLID CORE DOOR
(WD-2)
1 1/2"
8'-6"
1 1/2"
A3:
SOLID CORE WOOD
DOOR PAINTED
7
A12
1 1/2"
2
A12
8'-0"
1 1/2"
3'-0"
1
A12
1 1/2"
1 1/2"
1 1/2"
3'-4"
3'-0"
2
A12
1
A12
2
A12
8'-6"
1 1/2"
1
A12
1 1/2"
1
A12
POPLAR HEADER (PAINT TO
MATCH SOFFIT)
CLEAR ANODIZED
ALUMINUM FRAME
CLEAR ANODIZED
ALUMINUM FRAME
SCHEDULED DOOR
SCHEDULED DOOR
1
HEAD @ ALUM. DOOR FRAME
SCALE:
3"=1'-0"
2
HEAD @ SIDELIGHT ALUM. FRAME
SCALE:
3"=1'-0"
3
CENTER PIVOT HINGE
CLEAR ANODIZED
ALUMINUM FRAME
SCHEDULED DOOR
SCHEDULED DOOR
HEAD @ CLOSET DOOR
SCALE:
4
3"=1'-0"
1 1/2"
HEAD @ ALUM. DOOR FRAME
SCALE:
3"=1'-0"
1 1/2"
1/4" TEMPERED GLASS
ALUMINUM FRAME
NO.
SCHEDULED DOOR
SCHEDULED FLOORING
SCHEDULED FLOORING
EXISITNG SLAB
1 1/2"
1 1/2"
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
1 1/2"
4"
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
1 1/2"
UNDERCUT
AS REQ'D
EXISTING CONCRETE
SLAB
DOOR TYPES & DETAILS
CARPET TRANSITION
UNDER CENTERLINE OF
CLOSED DOOR
PROJECT NUMBER:
5
THRESHOLD @ DOOR
SCALE:
3"=1'-0"
6
SILL @ SIDELIGHT
SCALE:
3"=1'-0"
7
JAMB @ DOOR
SCALE:
3"=1'-0"
8
JAMB @ SIDELIGHT
SCALE:
3"=1'-0"
SHEET NO:
0213
DRAWING SCALE:
3/8" = 1'-0"
0 6" 1'
3'
5'
A12
ARCHITECT'S SPECIFICATIONS
SECTION 01631 - SUBSTITUTIONS
SECTION 06402 - INTERIOR ARCHITECTURAL WOODWORK
SECTION 09255 - GYPSUM BOARD ASSEMBLIES (continued)
A. Substitutions: Changes in products, materials, equipment, and methods of construction required by the Contract
Documents proposed by the Contractor after award of the Contract are considered to be requests for substitutions.
1.0 SUBMITTALS
1.1 STEEL FRAMING FOR WALLS AND PARTITIONS
A. Shop drawings showing location of each item, dimensioned plans and elevations, large-scale details, attachment
devices, and other components.
A. General: Provide steel framing members complying with the following requirements:
SECTION 01010 - SUMMARY OF WORK
1.0 SUBMITTALS
1. Protective Coating: ASTM A 653, G 40 hot-dip galvanized coating.
A. The Project consists of interior alteration to:
1. Project Location: 10 North Dearborn Street, 8th Floor, Chicago, Illinois, 60602.
A. Substitution Request Submittal: The Architect or Owner will consider requests for substitution if received within 15 days
after commencement of the Work. Requests received more than 15 days after commencement of the Work may be
considered or rejected at the discretion of the Architect.
2. Owner (Tenant): Civic Federation
SECTION 01026 - UNIT PRICES
A. Unit price is an amount proposed by bidders, stated on the Bid Form, as a price per unit of measurement for materials
or services added to or deducted from the Contract Sum by appropriate modification, if the estimated quantities of Work
required by the Contract Documents are increased or decreased.
SECTION 01027 - APPLICATIONS FOR PAYMENT
1. Submit 3 copies of each request for substitution for consideration. Submit requests in the form and according to
procedures required for change-order proposals.
2. Identify the product or the fabrication or installation method to be replaced in each request. Include related
Specification Section and Drawing numbers.
3. Provide complete documentation showing compliance with the requirements for substitutions.
4. Architect's Action: If necessary, the Architect will request additional information or documentation for evaluation
within one week of receipt of a request for substitution. The Architect will notify the Contractor of acceptance or
rejection of the substitution within 2 weeks of receipt of the request, or one week of receipt of additional information
or documentation, whichever is later. Acceptance will be in the form of a change order.
A. Payment-Application Forms: Use AIA Document G702 and Continuation Sheets G703 as the form for Applications for
Payment.
SECTION 01740 - WARRANTIES
SECTION 01030 - ALTERNATES (SEE BID FORM FOR ALTERNATES)
1.0 WARRANTY REQUIREMENTS
A. Definition: An alternate is an amount proposed by bidders and stated on the Bid Form for certain work defined in the
Bidding Requirements that may be added to or deducted from the Base Bid amount if the Owner decides to accept a
corresponding change in either the amount of construction to be completed, or in the products, materials, equipment,
systems, or installation methods described in the Contract Documents.
A. Related Damages and Losses: When correcting failed or damaged warranted construction, remove and replace
construction that has been damaged as a result of such failure or must be removed and replaced to provide access for
correction of warranted construction.
1. The cost or credit for each alternate is the net addition to or deduction from the Contract Sum to incorporate the
Alternate into the Work. No other adjustments are made to the Contract Sum.
SECTION 01035 - MODIFICATION PROCEDURES
1.0 MINOR CHANGES IN THE WORK
A. The Architect will issue supplemental instructions authorizing minor changes in the Work, not involving adjustment to
the Contract Sum or Contract Time, on AIA Form G710, Architect's Supplemental Instructions.
1.1 CHANGE ORDER PROPOSAL REQUESTS
A. Owner-Initiated Proposal Requests: The Architect will issue a detailed description of proposed changes in the Work
that will require adjustment to the Contract Sum or Contract Time. If necessary, the description will include supplemental
or revised Drawings and Specifications.
1. Proposal requests issued by the Architect are for information only. Do not consider them as an instruction either to
stop work in progress or to execute the proposed change.
2. Within 20 days of receipt of a proposal request, submit an estimate of cost necessary to execute the change to the
Architect for the Owner's review.
a. Include a list of quantities of products required and unit costs, with the total amount of purchases to be made.
Where requested, furnish survey data to substantiate quantities.
b. Indicate applicable taxes, delivery charges, equipment rental, and amounts of trade discounts.
c. Include a statement indicating the effect the proposed change in the Work will have on the Contract Time.
B. Contractor-Initiated Proposals: When latent or unforseen conditions require modifications to the Contract, the
Contractor may propose changes by submitting a request for a change to the Architect.
1. Include a statement outlining the reasons for the change and the effect of the change on the Work. Provide a
complete description of the proposed change. Indicate the effect of the proposed change on the Contract Sum and
Contract Time.
2. Include a list of quantities of products required and unit costs, with the total amount of purchases to be made.
Where requested, furnish survey data to substantiate quantities.
3. Indicate applicable taxes, delivery charges, equipment rental, and amounts of trade discounts.
4. Comply with requirements in Section "Product Substitutions" if the proposed change requires substitution of one
product or system for a product or system specified.
C. Proposal Request Form: Use AIA Document G709 for Change Order Proposal Requests.
1.2 CONSTRUCTION CHANGE DIRECTIVE
A. Construction Change Directive: When the Owner and the Contractor disagree on the terms of a Proposal Request, the
Architect may issue a Construction Change Directive on AIA Form G714. The Construction Change Directive instructs the
Contractor to proceed with a change in the Work, for subsequent inclusion in a Change Order.
B. Reinstatement of Warranty: When Work covered by a warranty has failed and been corrected by replacement or
rebuilding, reinstate the warranty by written endorsement. The reinstated warranty shall be equal to the original warranty
with an equitable adjustment for depreciation.
C. Replacement Cost: Upon determination that Work covered by a warranty has failed, replace or rebuild the Work to an
acceptable condition complying with requirements of the Contract Documents. The Contractor is responsible for the cost of
replacing or rebuilding defective Work regardless of whether the Owner has benefited from use of the Work through a
portion of its anticipated useful service life.
D. Owner's Recourse: Expressed warranties made to the Owner are in addition to implied warranties and shall not limit the
duties, obligations, rights, and remedies otherwise available under the law. Expressed warranty periods shall not be
interpreted as limitations on the time in which the Owner can enforce such other duties, obligations, rights, or remedies.
1. Rejection of Warranties: The Owner reserves the right to reject warranties and to limit selection to products with
warranties not in conflict with requirements of the Contract Documents.
1. Show details full size.
2. Show locations and sizes of furring, blocking, and hanging strips, including concealed blocking and reinforcing
specified in other Sections.
3. Show locations and sizes of cutouts and holes for plumbing fixtures, faucets, soap dispensers, and other items
installed in architectural woodwork.
4. Show veneer leaves with dimensions, grain direction, exposed face, and an identification number indicated for
each leaf. Identification number shall indicate the flitch and the sequence within the flitch for each leaf.
5. Apply WIC Certified Compliance Label to first page of shop drawings.
B. Documentation: Maintain detailed records on a time and material basis of work required by the Construction Change
Directive.
SECTION 01300 - SUBMITTALS
1.0 SUBMITTAL PROCEDURES
A. Coordination: Coordinate preparation and processing of submittals with performance of construction activities.
Transmit each submittal sufficiently in advance of performance of related construction activities to avoid delay.
1. Coordinate each submittal with fabrication, purchasing, testing, delivery, other submittals, and related activities that
require sequential activity.
1. Lumber with or for transparent finish, 24 by 24 inches, for each species and cut, finished on one side and one
edge.
2. Veneer leaves representative of and selected from flitches to be used for transparent-finished woodwork.
3. Wood-veneer-faced panel products, with or for transparent finish, 8 by 10 inches , for each species and cut.
Include at least one face-veneer seam and finish one-half of face as specified.
a. Step finish materials on sample to show and clearly define each coat.
4. Solid surfacing materials, 6 inches square.
5. Exposed cabinet hardware, one unit for each type and finish.
SECTION 08110 - STEEL DOORS AND FRAMES (NOT USED)
1.0 SUBMITTALS
a. The Architect reserves the right to withhold action on a submittal requiring coordination with other submittals
until all related submittals are received.
B. Shop Drawings showing fabrication and installation of steel doors and frames. Include details of each frame type,
elevations of door design types, conditions at openings, details of construction, location and installation requirements of
door and frame hardware and reinforcements, and details of joints and connections. Show anchorage and accessory
items.
C. Door Schedule: Submit schedule of doors and frames using same reference numbers for details and openings as
those on Contract Drawings.
1. Indicate coordination of glazing frames and stops with glass and glazing requirements.
a. Allow 2 weeks for initial review. Allow additional time if the Architect must delay processing to permit
coordination with subsequent submittals.
b. If an intermediate submittal is necessary, process the same as the initial submittal.
c. Allow 1 week for reprocessing each submittal.
d. No extension of Contract Time will be authorized because of failure to transmit submittals to the Architect
sufficiently in advance of the Work to permit processing.
B. Submittal Preparation: Place a permanent label or title block on each submittal for identification. Indicate the name of
the entity that prepared each submittal on the label or title block.
1.0 DEFINITIONS
SECTION 08211 - FLUSH WOOD DOORS
A. Remove: Remove and legally dispose of items except those indicated to be reinstalled, salvaged, or to remain the
Owner's property.
1.0 SUBMITTALS
1. Provide a space approximately 4 by 5 inches on the label or beside the title block on Shop Drawings to record the
Contractor's review and approval markings and the action taken.
2. Include the following information on the label for processing and recording action taken.
a. Project name.
b. Date.
c. Name and address of the Contractor.
d. Name and address of the subcontractor.
e. Name and address of the supplier.
f. Name of the manufacturer.
g. Drawing number and detail references, as appropriate.
C. Submittal Transmittal: Package each submittal appropriately for transmittal and handling. Transmit each submittal from
the Contractor to the Architect using a transmittal form. The Architect will not accept submittals received from sources
other than the Contractor.
1. On the transmittal, record relevant information and requests for data. On the form, or separate sheet, record
deviations from Contract Document requirements, including variations and limitations. Include Contractor's
certification that information complies with Contract Document requirements.
2. Transmittal Form: Use AIA Document G810.
1.1 SHOP DRAWINGS
A. Submit newly prepared information drawn accurately to scale. Highlight, encircle, or otherwise indicate deviations from
the Contract Documents. Do not reproduce Contract Documents or copy standard information as the basis of Shop
Drawings. Standard information prepared without specific reference to the Project is not a Shop Drawing.
B. Shop Drawings include fabrication and installation Drawings, setting diagrams, schedules, patterns, templates and
similar Drawings. Include the following information:
1. Dimensions.
2. Identification of products and materials included by sheet and detail number.
3. Compliance with specified standards.
4. Notation of coordination requirements.
5. Notation of dimensions established by field measurement.
6. Sheet Size: Except for templates, patterns and similar full-size Drawings, submit Shop Drawings on sheets at least
8-1/2 by 11 inches but no larger than 36 by 48 inches.
7. Initial Submittal: Submit one correctable, translucent, reproducible print and one blue- or black-line print for the
Architect's or Owner's review. The Architect or Owner will return the reproducible print.
8. Final Submittal: Submit 3 blue- or black-line prints and 2 additional prints where required for maintenance manuals,
plus the number of prints needed by the Architect or Owner for distribution. The Architect will retain 2 prints and
return the remainder.
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
1. Offset Configuration: Shadow-line design with offset projecting out from depth of stud.
2. Available Product: Subject to compliance with requirements, a product that may be incorporated in the Work
includes, but is not limited to, "Fire Trak" manufactured by Fire Trak Corp.
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
E. Steel Rigid Furring Channels: ASTM C 645, hat shaped, depth and minimum thickness of base (uncoated) metal as
follows:
Thickness: 0.0179 inch, unless otherwise indicated.
F. Furring Brackets: Serrated-arm type, adjustable, fabricated from corrosion-resistant steel sheet complying with ASTM C
645, minimum thickness of base (uncoated) metal of 0.0329 inch, designed for screw attachment to steel studs and steel
rigid furring channels used for furring.
1. Single-Leg Configuration: Asymmetric-shaped channel with face connected to a single flange by a single-slotted
leg (web).
2. Double-Leg Configuration: Hat-shaped channel with 1-1/2-inch wide face connected to flanges by double-slotted
or expanded-metal legs (webs).
3. Single- or Double-Leg Configuration: Asymmetric-shaped channel with face connected to a single flange by a
single-slotted leg (web) or hat-shaped channel, with 1-1/2-inch wide face connected to flanges by double-slotted
or expanded-metal legs (webs).DS
G. Steel Flat Strap and Backing Plate: Steel sheet for blocking and bracing complying with ASTM A 653 or ASTM A 568,
length and width as indicated, and with a minimum base metal (uncoated) thickness as follows:
1. Thickness: 0.0329 inch, 20 gauge where indicated.
A. Product Data: For each type of door. Include details of core and edge construction, trim for openings, and louvers.
B. Remove and Salvage: Items indicated to be removed and salvaged remain the Owner's property. Remove, clean, and
pack or crate items to protect against damage. Identify contents of containers and deliver to Owner's designated storage
area.
C. Remove and Reinstall: Remove items indicated; clean, service, and otherwise prepare them for reuse; store and
protect against damage. Reinstall items in the same locations or in locations indicated.
D. Existing to Remain: Protect construction indicated to remain against damage and soiling during selective demolition.
When permitted by the Architect, items may be removed to a suitable, protected storage location during selective
demolition and then cleaned and reinstalled in their original locations.
1. Include factory-finishing specifications.
B. Shop Drawings: Indicate location, size, and hand of each door; elevation of each kind of door; construction details not
covered in Product Data; location and extent of hardware blocking; and other pertinent data.
1. Indicate dimensions and locations of mortises and holes for hardware.
2. Indicate dimensions and locations of cutouts.
3. Indicate requirements for veneer matching.
4. Indicate doors to be factory finished and finish requirements.
5. Indicate fire ratings for fire doors.
1.0 SELECTIVE DEMOLITION
H. Fasteners for Metal Framing: Provide fasteners of type, material, size, corrosion resistance, holding power, and other
properties required to fasten steel framing and furring members securely to substrates involved; complying with the
recommendations of gypsum board manufacturers for applications indicated.
1.2 GYPSUM BOARD PRODUCTS
A. General: Provide gypsum board of types indicated in maximum lengths available that will minimize end-to-end butt
joints in each area indicated to receive gypsum board application.
1. Widths: Provide gypsum board in widths of 48 inches.
B. Gypsum Wallboard: ASTM C 36 and as follows:
C. Samples for Verification: As follows:
A. Demolish and remove existing construction only to the extent required by new construction and as indicated. Use
methods required to complete Work within limitations of governing regulations and as follows:
1. Neatly cut openings and holes plumb, square, and true to dimensions required. Use cutting methods least likely
to damage construction to remain or adjoining construction. To minimize disturbance of adjacent surfaces, use
hand or small power tools designed for sawing or grinding, not hammering and chopping. Temporarily cover
openings to remain.
3. Do not use cutting torches until work area is cleared of flammable materials. At concealed spaces, such as duct
and pipe interiors, verify condition and contents of hidden space before starting flame-cutting operations.
Maintain portable fire-suppression devices during flame-cutting operations.
5. Remove decayed, vermin-infested, or otherwise dangerous or unsuitable materials and promptly dispose of
off-site.
6. Locate selective demolition equipment throughout the structure and remove debris and materials so as not to
impose excessive loads on supporting walls, floors, or framing.
SECTION 08700 - FINISH HARDWARE
A. Furnish all finish hardware required to complete the work as indicated on the Drawings, as inferred through drawings
and specifications, and as herein specified.
B. Furnish all trim, attachments and fastenings specified or required for proper and complete installation.
C. Furnish thresholds, perimeter seals, gaskets and door bottoms.
D. Furnish All Glass Door Hardware.
E. Furnish power supplies for electric hardware.
A. General: Promptly dispose of demolished materials. Do not allow demolished materials to accumulate on-site.
D. Exterior Gypsum Soffit Board: ASTM C 931, with manufacturer's standard edges, of type and thickness indicated
below:
1. Type: Regular, unless otherwise indicated.
2. Type: Type X where required for fire-resistance-rated assemblies and where indicated.
3. Thickness: 5/8 inch, unless otherwise indicated.
C. Water-Resistant Gypsum Backing Board: ASTM C 630 and as follows:
1. Type: Regular, unless otherwise indicated.
2. Thickness: 5/8 inch, unless otherwise indicated.
1.1 GENERAL REQUIREMENTS
A. Proper kind and type: The hardware shall be the proper kind for its required use and shall fit its intended location
perfectly. Should any hardware, as specified, fail to meet the intended requirements or require any modifications to suit the
intended location, this matter, or any other necessary advance information, shall be brought to the attention of the architect
for correction or advice in ample time to avoid delay in the manufacture and delivery of the hardware.
7. Dispose of demolished items and materials promptly. On-site storage or sale of removed items is prohibited.
8. Return elements of construction and surfaces to remain to condition existing before start of selective demolition
operations.
1. Type: Regular for vertical surfaces, unless otherwise indicated.
2. Type: Type X where required for fire-resistance-rated assemblies.
3. Type: Sag-resistant type for ceiling surfaces.
4. Edges: Tapered.
5. Thickness: 5/8 inch, unless otherwise indicated.
6. Type: Foil backed where indicated.
1. Corner sections of doors approximately 8 by 10 inches with door faces and edgings representing the typical range
of color and grain for each species of veneer and solid lumber required. Finish sample with same materials
proposed for factory-finished doors.
1.0 DESCRIPTION
1. In order to insure proper placement and fit, all hardware in connection with metal door or metal frames shall be
made to template. Templates or physical hardware items shall be furnished to manufacturers concerned, and
shall be supplied sufficiently in advance to avoid delay in the work.
2. Warranty: All hardware shall be warranted for a period of one year from date of Substantial Completion or
additionally per the provisions of warranty sections. Defects in materials and workmanship occurring during the
warranty period shall be corrected to the complete satisfaction of the architect. Re-installation of defective
product during the warranty period will be the responsibility of the manufacturer/representative.
B. Disposal: Transport demolished materials off the Project site and legally dispose of them.
3. Electrical coordination: Before any electrically controlled and/or operated hardware is ordered, voltages must be
coordinate with Electrical trade in writing.
1.3
INSTALLING TRIM ACCESSORIES
A. General: For trim with back flanges intended for fasteners, attach to framing with same fasteners used for panels.
Otherwise, attach trim according to manufacturer's written instructions.
Generally, retain first option in paragraph below and show joints on Drawings to comply with ASTM C 840
requirements for spacing control (expansion) joints.
B. Control Joints: Install control joints according to ASTM C 840 and in specific locations approved by Architect for visual
effect.
1.4
FINISHING GYPSUM BOARD ASSEMBLIES
A. General: Treat gypsum board joints, interior angles, edge trim, control joints, penetrations, fastener heads, surface
defects, and elsewhere as required to prepare gypsum board surfaces for decoration. Promptly remove residual joint
compound from adjacent surfaces.
1.0 FERROUS METALS
1.2 SUBMITTALS
B. Prefill open joints, rounded or beveled edges, and damaged surface areas.
A. Steel Plates, Shapes, and Bars: ASTM A 36/A 36M.
A. Hardware list:
C. Apply joint tape over gypsum board joints, except those with trim having flanges not intended for tape.
See "Gypsum Board Finish Levels" Article in the Evaluations for a discussion of ASTM C 840 requirements.
B. Slotted Channel Framing: Cold-formed metal channels with flange edges returned toward web and with 9/16-inch- wide
slotted holes in webs at 2 inches o.c.
1. Width of Channels: 1-5/8 inches.
2. Depth of Channels: 1-5/8 inches.
3. Metal and Thickness: Uncoated steel complying with ASTM A 570, Grade 33; 0.0966- minimum thickness.
4. Finish: Rust-inhibitive, baked-on, acrylic enamel.
C. Welding Rods and Bare Electrodes: Select according to AWS specifications for metal alloy welded.
1.0 SUBMITTAL PROCEDURES
D. Deflection and Firestop Track: Top runner designed to allow partition heads to expand and contract with movement of
structure above while maintaining continuity of the assembly. Comply with requirements of ASTM C 645 except
configuration, of thickness indicated for studs and width to accommodate depth of studs indicated with flanges offset at
midpoint to accommodate gypsum board thickness.
A. Provide doors and frames complying with ANSI/SDI 100 "Recommended Specifications for Standard Steel Doors and
Frames" and as specified.
SECTION 02071 - SELECTIVE DEMOLITION FOR INTERIORS
SECTION 05500 - METAL FABRICATIONS
3. Processing: To avoid the need to delay installation as a result of the time required to process submittals, allow
sufficient time for submittal review, including time for resubmittals.
C. Deflection Track: Manufacturer's top runner complying with the requirements of ASTM C 645 and with 2-inch-deep
flanges.
A. Product Data for each type of door and frame specified, including details of construction, materials, dimensions,
hardware preparation, core, label compliance, sound ratings, profiles, and finishes.
B. Fire-Rated Door Assemblies: Units that comply with NFPA 80, are identical to door and frame assemblies tested for
fire-test-response characteristics per ASTM E 152, and are labeled and listed by UL, Warnock Hersey, or another testing
and inspecting agency acceptable to authorities having jurisdiction.
F. In no case shall the warranty for any portion of the Work be less than one year after the date of Owner's occupancy.
1.1 DISPOSAL OF DEMOLISHED MATERIALS
2. Coordinate transmittal of different types of submittals for related elements of the Work so processing will not be
delayed by the need to review submittals concurrently for coordination.
1. Thickness: 0.0179 inch, unless otherwise indicated.
2. Thickness: 0.0329 inch as follows:
a. For head runner, sill runner, jamb, and cripple studs at door and other openings.
b. In locations to receive cementitious backer units.
c. Where indicated.
3. Depth: 6 inches where indicated.
4. Depth: 3-5/8 inches where indicated.
5. Depth: 2-1/2 inches where indicated.
1.1 QUALITY ASSURANCE
E. Where the Contract Documents require a special warranty, or similar commitment on the Work or part of the Work, the
Owner reserves the right to refuse to accept the Work, until the Contractor presents evidence that entities required to
countersign such commitments are willing to do so.
4. Maintain adequate ventilation when using cutting torches.
1. After completion of the change, submit an itemized account and supporting data necessary to substantiate cost and
time adjustments to the Contract.
B. Steel Studs and Runners: ASTM C 645, with flange edges of studs bent back 90 degrees and doubled over to form
3/16-inch- wide minimum lip (return), and complying with the following requirements for minimum thickness of base
(uncoated) metal and for depth:
B. Samples for verification of the following:
2. Cut or drill from the exposed or finished side into concealed surfaces to avoid marring existing finished surfaces.
1. The Construction Change Directive contains a complete description of the change in the Work. It also designates
the method to be followed to determine change in the Contract Sum or Contract Time.
2. Protective Coating: ASTM A 653, G 40 hot-dip galvanized coating for framing members attached to and within 10
feet of exterior walls.
l. Within 15 days after award of contract, prepare and submit a hardware schedule (4 copies) to the architect for
review. This schedule shall be in vertical format only. Horizontal door/hardware schedules will be rejected.
2. The list shall identify each hardware item by manufacturer, including manufacturer's catalog number, cut sheets,
and exact location in the work, including door details and index.
3. Hardware list shall be in suitable form to facilitate review by the architect.
4. Review of the hardware schedule by the architect does not relieve the hardware supplier from the responsibility
of furnishing the job in a complete fashion.
5. The hardware supplier shall furnish to the Owner/Architect a copy of purchase orders showing the date of order
placement if requested.
D. Gypsum Board Finish Levels: Finish panels to levels indicated below, according to ASTM C 840, for locations
indicated:
1. Level 1: Embed tape at joints in ceiling plenum areas, concealed areas, and where indicated, unless a higher
level of finish is required for fire-resistance-rated assemblies and sound-rated assemblies.
2. Level 2: Embed tape and apply separate first coat of joint compound to tape, fasteners, and trim flanges where
panels are substrate for tile and where indicated.
1.1 PAINT
A. Shop Primers: Provide primers that comply with Division 9 Section "Painting."
B. Catalog cuts:
1. Submit catalog cuts of every item furnished for this project.
2. Show all finishes, sizes, catalog numbers and pictures. Explain fully all abbreviations.
B. Shop Primer for Ferrous Metal: Fast-curing, lead- and chromate-free, universal modified-alkyd primer complying with
performance requirements in FS TT-P-664; selected for good resistance to normal atmospheric corrosion, compatibility
with finish paint systems indicated, and capability to provide a sound foundation for field-applied topcoats despite
prolonged exposure.
SECTION 08800 - GLAZING
A. Safety Glass: Products complying with ANSI Z97.1 and testing requirements of 16 CFR Part 1201 for Category II
materials.
Level 3 is suitable for surfaces receiving medium- or heavy-textured finishes before painting or heavy
wallcoverings where lighting conditions are not critical.
3. Level 3: Embed tape and apply separate first and fill coats of joint compound to tape, fasteners, and trim flanges
where indicated.
Level 4 is suitable for surfaces receiving light-textured finish wallcoverings and flat paints. It is generally the
standard exposed finish.
1.2 FASTENERS
SECTION 09255 - GYPSUM BOARD ASSEMBLIES
A. Bolts and Nuts: Regular hexagon-head bolts, ASTM A 307, Grade ; with hex nuts, ASTM A ; and, where indicated, flat
washers.
B. Expansion Anchors: Anchor bolt and sleeve assembly of material indicated below with capability to sustain, without
failure, a load equal to six times the load imposed when installed in unit masonry and equal to four times the load imposed
when installed in concrete, as determined by testing per ASTM E 488, conducted by a qualified independent testing
agency.
1. Material: Carbon-steel components zinc-plated to comply with ASTM B 633, Class Fe/Zn 5.
A. Toggle Bolts: FS FF-B-588, tumble-wing type, class and style as needed.
4. Level 4: Embed tape and apply separate first, fill, and finish coats of joint compound to tape, fasteners, and trim
flanges at panel surfaces that will be exposed to view, unless otherwise indicated.
1.0 STEEL FRAMING COMPONENTS FOR SUSPENDED AND FURRED CEILINGS
A. General: Provide components complying with ASTM C 754 for conditions indicated.
B. Powder-Actuated Fasteners in Concrete: Fastener system of type suitable for application indicated, fabricated from
corrosion-resistant materials, with clips or other accessory devices for attaching hangers of type indicated, and with
capability to sustain, without failure, a load equal to 10 times that imposed by ceiling construction, as determined by testing
according to ASTM E 1190 conducted by a qualified independent testing agency.
Level 5 is suitable for surfaces receiving gloss and semigloss enamels and surfaces subject to severe lighting. It
is considered a high-quality gypsum board finish.
5. Level 5: Embed tape and apply separate first, fill, and finish coats of joint compound to tape, fasteners, and trim
flanges, and apply skim coat of joint compound over entire surface where indicated.
NO.
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
E. Glass-Mat Gypsum Sheathing Board: Finish according to manufacturer's written instructions for use as exposed soffit
board.
C. Wire Ties: ASTM A 641, Class 1 zinc coating, soft temper, 0.062 inch thick.
F. Glass-Mat, Water-Resistant Backing Panels: Finish according to manufacturer's written instructions.
SECTION 06200 - FINISH CARPENTRY
D. Wire Hangers: ASTM A 641, Class 1 zinc coating, soft temper, 0.162-inch diameter.
A. Hardwood Trim: Provide finished hardwood lumber and moldings complying with the following requirements:
E. Hanger Rods: Mild steel and zinc coated or protected with rust-inhibitive paint.
G. Cementitious Backer Units: Finish according to manufacturer's written instructions.
1. Species: Clear, kiln-dried white hardwoods.
2. Species and Cut: Rift-sawn, clear, kiln-dried red oak selected for compatible grain and color.
3. Texture: Surfaced (smooth).
4. Lumber for Transparent Finish (Stained or Clear): Solid lumber stock.
5. Lumber for Painted Finish: Glued-up lumber or solid lumber stock.
F. Steel Resilient Furring Channels: Manufacturer's standard product designed to reduce sound transmission, fabricated
from steel sheet complying with ASTM A 653 or ASTM A 568 to form 1/2-inch-deep channel of the following configuration:
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
1. Single-Leg Configuration: Asymmetric-shaped channel with face connected to a single flange by a single-slotted
leg (web).
2. Double-Leg Configuration: Hat-shaped channel with 1-1/2-inch-wide face connected to flanges by double-slotted
or expanded-metal legs (webs).
3. Single- or Double-Leg Configuration: Asymmetric-shaped channel with face connected to a single flange by a
single-slotted leg (web) or hat-shaped channel, with 1-1/2-inch-wide face connected to flanges by double-slotted
or expanded-metal legs (webs).
G. Grid Suspension System for Interior Ceilings: ASTM C 645, manufacturer's standard direct-hung grid suspension
system composed of main beams and cross-furring members that interlock to form a modular supporting network.
SPECIFICATIONS
PROJECT NUMBER:
0213
DRAWING SCALE:
AS NOTED
SHEET NO:
A13
SECTION 09680 - CARPET
SECTION 09920 - INTERIOR PAINTING
SECTION 09920 - INTERIOR PAINTING (Continued)
1.0 SUBMITTALS
1.0 SUMMARY
3. Low-Luster, Acrylic-Enamel Finish: 2 finish coats over a primer.
A. This Section includes surface preparation and field painting of the following:
1.0 SUBMITTALS
A. Product Data for each type of carpet material, carpet cushion, and installation accessory specified. Submit
manufacturer's printed data on physical characteristics, durability, fade resistance, and fire-test-response characteristics.
Submit methods of installation for each type of substrate.
A. Samples for Verification: Full-size units of each type of ceiling assembly indicated; in sets for each color, texture, and
pattern specified, showing the full range of variations expected in these characteristics.
B. Shop Drawings showing columns, doorways, enclosing walls or partitions, built-in cabinets, and locations where cutouts
are required in carpet. Indicate the following:
ARCHITECT'S SPECIFICATIONS
SECTION 09512 - ACOUSTICAL TILE CEILINGS
1. 6" square samples of each acoustical tile type, pattern, and color.
2. Set of 12-inch long samples of concealed suspension system members.
3. Set of 12-inch long samples of exposed moldings for each color and system type required.
1.1 ACOUSTICAL TILES, GENERAL
A. Acoustical Tile Standard: Provide manufacturer's standard tiles of configuration indicated that comply with ASTM E
1264 classifications as designated by types, patterns, acoustical ratings, and light reflectances, unless otherwise indicated.
1.2 METAL SUSPENSION SYSTEMS, GENERAL
A. Metal Suspension System Standard: Provide manufacturer's standard metal suspension systems of types, structural
classifications, and finishes indicated that comply with applicable ASTM C 635 requirements.
B. Finishes and Colors, General: Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for
recommendations for applying and designating finishes. Provide manufacturer's standard factory-applied finish for type of
system indicated.
1. High-Humidity Finish: Comply with ASTM C 635 requirements for "Coating Classification for Severe Environment
Performance" where high-humidity finishes are indicated.
C. Attachment Devices: Size for five times design load indicated in ASTM C 635, Table 1, Direct Hung, unless otherwise
indicated.
1. Postinstalled Powder-Actuated Fasteners in Concrete: Fastener system of type suitable for application indicated,
fabricated from corrosion-resistant materials, with clips or other accessory devices for attaching hangers of type
indicated, and with capability to sustain, without failure, a load equal to 10 times that imposed by ceiling
construction, as determined by testing per ASTM E 1190, conducted by a qualified testing and inspecting
agency.
1. Carpet type, color, and dye lot.
2. Locations where dye lot changes occur.
3. Seam locations, types, and methods.
4. Type of subfloor.
5. Type of installation.
6. Pattern type, repeat size, location, direction, and starting point.
7. Pile direction.
8. Type, color, and location of insets and borders.
9. Type of cushion, if specified.
10. Type, color, and location of edge, transition, and other accessory strips.
11. Transition details to other flooring materials.
C. Samples for verification of the following products, in manufacturer's standard sizes, showing the full range of color,
texture, and pattern variations expected. Prepare Samples from the same material to be used for the Work. Label each
sample with manufacturer's name, material type, color, pattern, and designation indicated on Drawings and carpet
schedule. Submit the following:
1. 24 -inch square Samples of each type of carpet material required.
2. 12-inch Samples of each type of exposed edge stripping and accessory item.
3. 6-inch Samples of each type of carpet cushion.
1. Exposed interior items and surfaces.
2. Surface preparation, priming, and finish coats specified in this Section are in addition to shop priming and surface
treatment specified in other Sections.
B. Paint exposed surfaces, except where the paint Schedule or elevations or details indicates that a surface or material is
not to be painted or is to remain natural. If the paint Schedule does not specifically mention an item or a surface, paint the
item or surface the same as similar adjacent materials or surfaces whether or not the Schedule indicates colors. If the
Schedule does not indicate color or finish, the Architect will select from standard colors and finishes available.
1.2 SUBMITTALS
A. Product Data: For each paint system specified. Include block fillers and primers.
1. Material List: Provide an inclusive list of required coating materials. Indicate each material and cross-reference
specific coating, finish system, and application. Identify each material by manufacturer's catalog number and
general classification.
2. Manufacturer's Information: Provide manufacturer's technical information, including label analysis and
instructions for handling, storing, and applying each coating material proposed for use.
3. Certification by the manufacturer that products supplied comply with local regulations controlling use of volatile
organic compounds (VOCs).
B. Samples for Verification: Of each color and material to be applied, with texture to simulate actual conditions, on
representative Samples of the actual substrate.
1. Provide stepped Samples, defining each separate coat, including block fillers and primers. Use representative
colors when preparing Samples for review. Resubmit until required sheen, color, and texture are achieved.
D. Schedule of carpet using same room designations indicated on Drawings.
1.3 PROJECT CONDITIONS
E. Maintenance data for carpet and cushion to include in the operation and maintenance manual specified in Division 1.
Include the following:
1. Methods for maintaining carpet and carpet cushion, including manufacturer's recommended frequency for
maintaining carpet.
2. Precautions for cleaning materials and methods that could be detrimental to finishes and performance. Include
cleaning and stain-removal products and procedures.
D. Wire Hangers, Braces, and Ties: Provide wires complying with the following requirements:
1.1 QUALITY ASSURANCE
A. Apply water-based paints only when the temperature of surfaces to be painted and surrounding air temperatures are
between 50 and 90 deg F.
B. Apply solvent-thinned paints only when the temperature of surfaces to be painted and surrounding air temperatures are
between 45 and 95 deg F.
C. Do not apply paint when the relative humidity exceeds 85 percent; or at temperatures less than 5 deg F above the dew
point; or to damp or wet surfaces.
1. Zinc-Coated Carbon-Steel Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper.
2. Size: Select wire diameter so its stress at three times hanger design load (ASTM C 635, Table 1, Direct Hung)
will be less than yield stress of wire, but provide not less than 0.106-inch diameter wire.
1.3 INSTALLATION
A. General: Install acoustical tile ceilings to comply with publications referenced below per manufacturer's written
instructions and CISCA's "Ceiling Systems Handbook."
1. Standard for Ceiling Suspension System Installations: Comply with ASTM C 636.
A. Installer Qualifications: Engage an experienced Installer who is certified by the Floor Covering Installation Board (FCIB)
or who can demonstrate compliance with FCIB certification program requirements.
B. Carpet Fire-Test-Response Characteristics: Provide carpet with the following fire-test-response characteristics as
determined by testing identical products per test method indicated below by UL or another testing and inspecting agency
acceptable to authorities having jurisdiction. Identify carpet with appropriate markings of applicable testing and inspecting
agency.
1. Surface Flammability: Passes CPSC 16 CFR, Part 1630.
2. Flame Spread: 25 or less per ASTM E 84.
3. Smoke Developed: 450 or less per ASTM E 84.
2. U.B.C.'s "Metal Suspension Systems for Acoustical Tile and for Lay-in Panel Ceilings": U.B.C. Standard 25-2.
1.2 DELIVERY, STORAGE, AND HANDLING
1.4 MANUFACTURERS
Products: Subject to compliance with requirements, provide one of the products in the paint Schedule.
A. Manufacturers Names: The following manufacturers are referred to in the paint Schedule by use of shortened versions
of their names, which are shown in parentheses:
1. Devoe & Raynolds Co. (Devoe).
2. Fuller-O'Brien Paints (Fuller).
3. Glidden Co. (The) (Glidden).
4. Benjamin Moore & Co. (Moore).
5. PPG Industries, Inc. (PPG).
6. Pratt & Lambert, Inc. (P & L).
7. Sherwin-Williams Co. (S-W).
SECTION 09651 - RESILIENT TILE FLOORING
A. General: Comply with the Carpet and Rug Institute's CRI 104, Section 5: "Storage and Handling."
1.5 PREPARATION
A. Product Data: For each type of product specified.
B. Deliver materials to Project site in original factory wrappings and containers, labeled with identification of manufacturer,
brand name, and lot number.
B. Samples for Verification: Full-size tiles of each different color and pattern of resilient floor tile specified, showing the full
range of variations expected in these characteristics.
C. Store materials on-site in original undamaged packages, inside well-ventilated area protected from weather, moisture,
soilage, extreme temperatures, and humidity. Lay flat, with continuous blocking off ground.
A. General: Remove hardware and hardware accessories, plates, machined surfaces, lighting fixtures, and similar items
already installed that are not to be painted. If removal is impractical or impossible because of the size or weight of the
item, provide surface-applied protection before surface preparation and painting. After completing painting operations in
each space or area, reinstall items removed using workers skilled in the trades involved.
a. Primer: Alkali-resistant, acrylic-latex, interior primer applied at spreading rate recommended by the manufacturer
to achieve a total dry film thickness of not less than 1.0 mil.
1) Devoe: 50801 Wonder-Tones Interior Vinyl Latex Primer-Sealer.
2) Fuller: 220-20 Pro-Tech Interior Latex Wall Primer and Sealer.
3) Glidden: 5111 Spred Ultra Latex Primer-Sealer.
4) Moore: Regal First Coat Interior Latex Primer & Underbody #216.
5) PPG: 6-603 Speedhide Interior/Exterior Acrylic Latex Alkali Resistant Primer.
6) P & L: Z/F 1004 Suprime "4" Interior Latex Wall Primer.
b. First and Second Coats: Low-luster (eggshell or satin), acrylic-latex, interior enamel applied at spreading rate
recommended by the manufacturer to achieve a total dry film thickness of not less than 2.8 mils.
1) Devoe: 34XX Wonder-Tones Interior Latex Eggshell Enamel.
2) Fuller: 212-XX AA Enamel Interior Acrylic Latex Eggshell Enamel.
3) Glidden: 4100 Series Spred Ultra Eggshell Latex Wall & Trim Paint.
4) Moore: Moore's Regal AquaVelvet #319.
5) PPG: 89 Line Manor Hall Eggshell Latex Wall and Trim Enamel.
6) P & L: Z/F 4000 Series Accolade Interior Velvet.
4. Semigloss, Acrylic-Enamel Finish: 2 finish coats over a primer.
a. Primer: Alkali-resistant, acrylic-latex, interior primer applied at spreading rate recommended by the manufacturer
to achieve a total dry film thickness of not less than 1.0 mil.
1) Devoe: 50801 Wonder-Tones Interior Vinyl Latex Primer-Sealer.
2) Fuller: 220-20 Pro-Tech Interior Latex Wall Primer and Sealer.
3) Glidden: Primer not required over this substrate.
4) Moore: Regal First Coat Interior Latex Primer & Underbody #216.
5) PPG: 6-603 Speedhide Interior/Exterior Acrylic Latex Alkali Resistant Primer on highly alkaline surfaces.
6) P & L: Z/F 1001 Suprime "1" 100 Percent Acrylic Multi-Purpose Primer.
GARNETT ARCHITECTS, LLC
ARCHITECTURE . PLANNING . INTERIOR DESIGN
140 SOUTH DEARBORN STREET, SUITE 410
CHICAGO, ILLINOIS 60603
312.447.0747 TEL
312.447.0748 FAX
WWW.GARNETTARCHITECTS.COM
b. First and Second Coats: Semigloss, acrylic-latex, interior enamel applied at spreading rate recommended by the
manufacturer to achieve a total dry film thickness of not less than 2.6 mils.
1) Devoe: 39XX Wonder-Tones Semi-Gloss Interior Latex Enamel.
2) Fuller: 214-XX AA Enamel Interior Acrylic Latex Semi-Gloss Enamel.
3) Glidden: 8200 Series Spred Ultra Latex Semi-Gloss Enamel.
4) Moore: Moore's Regal AquaGlo Vinyl-Acrylic Latex Enamel #333.
5) PPG: 88-110 Satinhide Interior Enamel Wall & Trim Lo-Lustre Semi-Gloss Latex.
6) P & L: Z/F 4100 Series Accolade Interior Semi-Gloss.
5. Semigloss, Alkyd-Enamel Finish: 2 finish coats over a primer.
a. Primer: Alkali-resistant, alkyd- or latex-based, interior primer, as recommended by the manufacturer for this
substrate, applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of
not less than 1.0 mil.
1) Devoe: 51701 Wonder-Prime Interior All-Purpose Latex Primer Sealer & Vapor Barrier.
2) Fuller: 220-07 Interior Alkyd Enamel Undercoat.
3) Glidden: 5111 Spred Ultra Latex Primer-Sealer.
4) Moore: Regal First Coat Interior Latex Primer & Underbody #216.
5) PPG: 6-603 Speedhide Interior/Exterior Acrylic Latex Alkali Resistant Primer.
6) P & L: Z/F 1001 Suprime "1" 100 Percent Acrylic Multi-Purpose Primer.
7) S-W:. ProMar 200 Latex Wall Primer B28W200.
1.0 SUBMITTALS
1. For resilient accessories, manufacturer's standard-size samples, but not less than 12 long, of each resilient
accessory color and pattern specified.
1.3 PROJECT CONDITIONS
A. General: Comply with CRI 104, Section 6: "Site Conditions."
C. Maintenance Data: For resilient floor tile to include in the maintenance manuals specified in Division 1.
1.1 RESILIENT TILE
A. Rubber Floor Tile: Products complying with ASTM F 1344 and with requirements specified in the Resilient Tile Flooring
Schedule.
B. Vinyl Composition Floor Tile: Products complying with ASTM F 1066 and with requirements specified in the Resilient
Tile Flooring Schedule.
1. Provide barrier coats over incompatible primers or remove and reprime.
C. Subfloor Moisture Conditions: Moisture emission rate of not more than 3 lb/1000 sq. ft./24 hours when tested by
calcium chloride moisture test in compliance with CRI 104, 6.2.1, with subfloor temperatures not less than 55 deg F.
2. Cementitious Materials: Prepare concrete, concrete masonry block, cement plaster, and mineral- fiber-reinforced
cement panel surfaces to be painted. Remove efflorescence, chalk, dust, dirt, grease, oils, and release agents.
Roughen as required to remove glaze. If hardeners or sealers have been used to improve curing, use
mechanical methods of surface preparation.
D. Subfloor Alkalinity Conditions: A pH range of 5 to 9 when subfloor is wetted with potable water and pHydrion paper is
applied.
1.4 WARRANTY
B. Rubber Accessory Moldings: Products complying with requirements specified in the Resilient Tile Flooring Schedule.
1.3 INSTALLATION ACCESSORIES
A. Trowelable Leveling and Patching Compounds: Latex-modified, portland-cement-based formulation provided or
approved by flooring manufacturer for applications indicated.
B. Adhesives: Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions
indicated.
A. General Warranty: The special warranty specified in this Article shall not deprive the Owner of other rights the Owner
may have under other provisions of the Contract Documents and shall be in addition to, and run concurrent with, other
warranties made by the Contractor under requirements of the Contract Documents.
B. Special Carpet Warranty: If used, submit a written warranty executed by carpet manufacturer and Installer agreeing to
repair or replace carpet that does not meet requirements or that fails in materials or workmanship within the specified
warranty period. Failures include, but are not limited to, more than 10 percent loss of face fiber, edge raveling, snags,
runs, and delamination.
C. Warranty Period: 10 years from date of Substantial Completion.
1.5 EXTRA MATERIALS
SECTION 09653 - RESILIENT WALL BASE AND ACCESSORIES
1.0 SUBMITTALS
C. Surface Preparation: Clean and prepare surfaces to be painted according to manufacturer's written instructions for
each particular substrate condition and as specified.
B. Space Enclosure and Environmental Limitations: Do not install carpet until work in space is completed and nominally
dry, work above ceilings is complete, and ambient temperature and humidity conditions are and will be continuously
maintained at values near those indicated for final occupancy.
1.2 RESILIENT ACCESSORIES
A. Rubber Wall Base: Products complying with FS SS-W-40, Type I and with requirements specified in the Resilient Tile
Flooring Schedule.
B. Cleaning: Before applying paint or other surface treatments, clean the substrates of substances that could impair the
bond of the various coatings. Remove oil and grease before cleaning.
A. Furnish extra materials described below that match products installed, are packaged with protective covering for
storage, and are identified with labels clearly describing contents.
a. Use abrasive blast-cleaning methods if recommended by paint manufacturer.
b. Determine alkalinity and moisture content of surfaces by performing appropriate tests. If surfaces are
sufficiently alkaline to cause the finish paint to blister and burn, correct this condition before application.
Do not paint surfaces where moisture content exceeds that permitted in manufacturer's written
instructions.
c. Clean concrete floors to be painted with a 5 percent solution of muriatic acid or other etching cleaner.
Flush the floor with clean water to remove acid, neutralize with ammonia, rinse, allow to dry, and vacuum
before painting.
3. Ferrous Metals: Clean ungalvanized ferrous-metal surfaces that have not been shop coated; remove oil, grease,
dirt, loose mill scale, and other foreign substances. Use solvent or mechanical cleaning methods that comply
with the Steel Structures Painting Council's (SSPC) recommendations.
a. Blast steel surfaces clean as recommended by paint system manufacturer and according to requirements
of SSPC-SP 10.
b. Treat bare and sandblasted or pickled clean metal with a metal treatment wash coat before priming.
c. Touch up bare areas and shop-applied prime coats that have been damaged. Wire-brush, clean with
solvents recommended by paint manufacturer, and touch up with the same primer as the shop coat.
1.6 INTERIOR PAINT SCHEDULE
A. Product Data: For each type of product specified.
B. Samples for Verification: In manufacturer's standard sizes, but not less than 12 inches long, of each product color and
pattern specified.
1. Carpet: Before installation begins, furnish quantity of full-width units equal to 5 percent of amount installed.
PART 2 - PRODUCTS
A. Concrete and Masonry (Other than Concrete Masonry Units): Provide the following paint systems over interior concrete
and brick masonry surfaces:
2.0 CARPET
1. Flat Acrylic Finish: 2 finish coats over a primer.
1.1 RESILIENT WALL BASE
A. Rubber Wall Base: Products complying with FS SS-W-40, Type I and with requirements specified in the Resilient Wall
Base and Accessory Schedule.
A. Products: Subject to compliance with requirements, provide one of the products specified in each carpet Product Data
sheet at end of this Section.
2.1 INSTALLATION ACCESSORIES
B. Vinyl Wall Base: Products complying with FS SS-W-40, Type II and with requirements specified in the Resilient Wall
Base and Accessory Schedule.
A. Trowelable Underlayments and Patching Compounds: As recommended by the carpet manufacturer.
1.2 INSTALLATION ACCESSORIES
B. Adhesives: Water-resistant, mildew-resistant, nonstaining type to suit products and subfloor conditions indicated and to
comply with flammability requirements for installed carpet as recommended by the carpet manufacturer.
A. Adhesives: Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions
indicated.
C. Seaming Cement: Hot-melt adhesive tape or similar product recommended by carpet manufacturer for taping seams
and butting cut edges at backing to form secure seams and to prevent pile loss at seams.
a. Primer: Alkali-resistant, acrylic-latex, interior primer applied at spreading rate recommended by the manufacturer
to achieve a total dry film thickness of not less than 1.0 mil.
1) Devoe: 51701 Wonder-Prime Interior All-Purpose Latex Primer Sealer & Vapor Barrier.
2) Fuller: 220-17 Acrylic Concrete and Masonry Primer Sealer.
3) Glidden: 5111 Spred Ultra Latex Primer-Sealer.
4) Moore: Regal First Coat Interior Latex Primer & Underbody #216.
5) PPG: 6-2 Speedhide Interior Quick-Drying latex Sealer.
6) P & L: Z/F 1004 Suprime "4" Interior Latex Wall Primer.
b. First and Second Coats: Flat, latex-based, interior paint applied at spreading rate recommended by the
manufacturer to achieve a total dry film thickness of not less than 2.5 mils.
1.3 INSTALLATION
A. General: Install resilient products according to manufacturer's written installation instructions.
1. Install wall base in lengths as long as practicable without gaps at seams and with tops of adjacent pieces aligned.
A. General: Comply with carpet manufacturer's installation recommendations to prepare substrates indicated to receive
carpet installation.
B. Level subfloor within 1/4 inch in 10 feet, noncumulative, in all directions. Sand or grind protrusions, bumps, and ridges.
Patch and repair cracks and rough areas. Fill depressions.
1) Devoe: 36XX Wonder-Tones Interior Latex Flat Wall Paint.
2) Fuller: 602-XX Liquid Velvet Latex Wall Paint.
3) Glidden: 4000 Series Spred Ultra Flat Latex Wall and Trim Paint.
4) Moore: Regal Wall Satin #215.
5) PPG: 80 Line Wallhide Interior Wall Flat Latex Paint.
6) P & L: Z/F 2000 Series Vapex Latex Flat Wall Finish.
2. Odorless, Flat Alkyd Finish: 2 finish coats over a primer.
2. Tightly adhere wall base to substrate throughout length of each piece, with base in continuous contact with
horizontal and vertical substrates.
3. Form outside corners on job, from straight pieces of maximum lengths possible, without whitening at bends.
Shave back of base at points where bends occur and remove strips perpendicular to length of base that are only
deep enough to produce a snug fit without removing more than half the wall base thickness.
4. Form inside corners on job, from straight pieces of maximum lengths possible, by cutting an inverted V-shaped
notch in toe of wall base at the point where corner is formed. Shave back of base where necessary to produce a
snug fit to substrate.
C. Place resilient products so they are butted to adjacent materials and bond to substrates with adhesive. Install reducer
strips at edges of flooring that would otherwise be exposed.
1) Devoe: 50801 Wonder-Tones Interior Vinyl Latex Primer-Sealer.
2) Fuller: 220-20 Pro-Tech Interior Latex Wall Primer and Sealer.
3) Glidden: Primer not required over this substrate.
4) Moore: Regal First Coat Interior Latex Primer & Underbody #216.
5) PPG: 6-603 Speedhide Interior/Exterior Acrylic Latex Alkali Resistant Primer on highly alkaline surfaces.
6) P & L: Z/F 1001 Suprime "1" 100 Percent Acrylic Multi-Purpose Primer.
c. First and Second Coats: Semigloss, acrylic-latex, interior enamel applied at spreading rate recommended by the
manufacturer to achieve a total dry film thickness of not less than 2.6 mils.
1) Devoe: 39XX Wonder-Tones Semi-Gloss Interior Latex Enamel.
2) Fuller: 214-XX AA Enamel Interior Acrylic Latex Semi-Gloss Enamel.
3) Glidden: 8200 Series Spred Ultra Latex Semi-Gloss Enamel.
4) Moore: Moore's Regal AquaGlo Vinyl-Acrylic Latex Enamel #333.
5) PPG: 88-110 Satinhide Interior Enamel Wall & Trim Lo-Lustre Semi-Gloss Latex.
6) P & L: Z/F 4100 Series Accolade Interior Semi-Gloss.
5. Semigloss, Alkyd-Enamel Finish: 2 finish coats over a primer.
a. Primer: Alkali-resistant, alkyd- or latex-based, interior primer, as recommended by the manufacturer for this
substrate, applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of
not less than 1.0 mil.
1) Devoe: 51701 Wonder-Prime Interior All-Purpose Latex Primer Sealer & Vapor Barrier.
2) Fuller: 220-07 Interior Alkyd Enamel Undercoat.
3) Glidden: 5111 Spred Ultra Latex Primer-Sealer.
4) Moore: Regal First Coat Interior Latex Primer & Underbody #216.
5) PPG: 6-603 Speedhide Interior/Exterior Acrylic Latex Alkali Resistant Primer.
6) P & L: Z/F 1001 Suprime "1" 100 Percent Acrylic Multi-Purpose Primer.
7) S-W:. ProMar 200 Latex Wall Primer B28W200.
b. First and Second Coats: Odorless, semigloss, alkyd, interior enamel applied at spreading rate recommended by
the manufacturer to achieve a total dry film thickness of not less than 2.6 mils.
1) Devoe: 26XX Velour Interior Alkyd Semi-Gloss Enamel.
2) Fuller: 206-XX Interior Alkyd Semi-Gloss Enamel.
3) Glidden: UH 8400 Ultra Traditional Alkyd Semi-Gloss Enamel.
4) Moore: Moore's Alkyd Dulamel #207.
5) PPG: 27 Line Wallhide Low Odor Interior Enamel Wall and Trim Semi-Gloss Oil.
6) P & L: S/D 5700 Cellu-Tone Alkyd Satin Enamel.
7) S-W: Classic 99 Interior Alkyd Semi-Gloss Enamel A-40 Series.
A. Concrete Masonry Units: Provide the following finish systems over interior concrete masonry block units: Semigloss,
Acrylic-Enamel Finish: 2 finish coats over a high-performance, latex-based, block filler.
B. Gypsum Board: Provide the following finish systems over interior gypsum board surfaces: Flat Acrylic Finish: 2 finish
coats over a latex-based, interior primer.
C. Hollow Metal Window and Door Frames, Fire extinguisher Cabinets: Semigloss, Alkyd-Enamel Finish: One finish coat
over an enamel undercoater and a quick-drying, rust-inhibitive, alkyd-based or epoxy-metal primer.
SECTION 09950 - WALL COVERINGS
1.0 SUBMITTALS
2.2 PREPARATION
B. Apply resilient wall base to walls, columns, pilasters, casework and cabinets in toe spaces, and other permanent
fixtures in rooms and areas where base is required.
b. First and Second Coats: Odorless, semigloss, alkyd, interior enamel applied at spreading rate recommended by
the manufacturer to achieve a total dry film thickness of not less than 2.6 mils.
1. Use leveling and patching compounds to fill cracks, holes, and depressions in subfloor as recommended by the
carpet manufacturer.
C. Remove subfloor coatings, including curing compounds, and other substances that are incompatible with adhesives and
that contain soap, wax, oil, or silicone.
D. Broom or vacuum clean subfloors to be covered with carpet. Following cleaning, examine subfloors for moisture,
alkaline salts, carbonation, or dust.
2.3 INSTALLATION
a. Primer: Alkali-resistant, latex-based, interior primer applied at spreading rate recommended by the manufacturer
to achieve a total dry film thickness of not less than 1.1 mils.
1) Devoe: 51701 Wonder-Prime Interior All-Purpose Latex Primer Sealer & Vapor Barrier.
2) Fuller: 220-20 Pro-Tech Latex Wall Primer Sealer, White.
3) Glidden: 5212 Glid-Guard Alkali-Resistant Primer.
4) Moore: Regal First Coat Interior Latex Primer & Underbody #216.
5) PPG: 6-2 Speedhide Interior Quick-Drying Latex Sealer.
6) P & L: Z/F 1004 Suprime "4" Interior Latex Wall Primer.
7) S-W: ProMar 200 Interior Latex Wall Primer B28W200.
A. Samples for verification in sets for each color, texture, and pattern specified, showing the full range of variations
expected in these characteristics.
1. Wall Covering Material: Full-width sample, not less than 36 inches long, from dye lot used for the Work. Mark the
top and face of material.
A. Maintenance data for wall covering to include in the operation and maintenance manual specified in Division 1.
1.1 QUALITY ASSURANCE
A. Fire-Test-Response Characteristics: Provide wall coverings with the following surface-burning characteristics as
determined by testing identical products per ASTM E 84 by UL or another testing and inspecting agency acceptable to
authorities having jurisdiction.
1. Flame Spread: 25 or less.
2. Smoke Developed: 450 or less.
B. Comply with carpet manufacturer's recommendations for seam locations and direction of carpet; maintain uniformity of
carpet direction and lay of pile. At doorways, center seams under door in closed position. Do not bridge building
expansion joints with continuous carpet.
C. Cut and fit carpet to butt tightly to vertical surfaces, permanent fixtures, and built-in furniture including cabinets, pipes,
outlets, edgings, thresholds, and nosings. Bind or seal cut edges as recommended by carpet manufacturer.
D. Extend carpet into toe spaces, door reveals, closets, open-bottomed obstructions, removable flanges, alcoves, and
similar openings.
E. Install pattern as shown on the finish plans.
-
1.2 ADHESIVES
A. Direct Glue-Down Installation: Comply with CRI 104, Section 8: "Direct Glue-Down."
NO.
b. First and Second Coats: Odorless, flat, alkyd, interior paint applied at spreading rate recommended by the
manufacturer to achieve a total dry film thickness of not less than 3.0 mils.
1) Devoe: 21XX Velour Interior Alkyd Flat Wall Paint.
2) Fuller: 101-XX Liquid Velvet Alkyd Flat Wall Paint.
3) Glidden: 5700 Ultra-Hide Alkyd Flat Wall Enamel.
4) Moore: Moore's Alkyd Sani-Flat #204.
5) PPG: 6-50 Series Speedhide Alkyd Flat Enamel.
6) P & L: S/D 6700 Series Lyt-All Flowing Flat.f
7) S-W: ProMar 200 Alkyd Flat Wall Paint B32W201.
03/13/15
ISSUED FOR BID AND PERMIT
DATE
REVISION
A. General: Mildew-resistant, nonstaining adhesive, for use with specific wood-veneer wall covering and substrate
application, as recommended by wall covering manufacturer.
1.3 PREPARATION
A. Prepare substrates to achieve a smooth, dry, clean surface free of flaking, unsound coatings, cracks, and defects.
1. Painted Surfaces: Treat areas susceptible to pigment bleeding.
2. Metals: If not factory primed, clean and apply rust-inhibitive zinc primer.
3. Moisture Content: Maximum of 5 percent on new plaster, concrete, and concrete masonry units when tested with
an electronic moisture meter.
4. Prime new gypsum board with primer recommended by wall covering manufacturer.
5. Allow new plaster to cure. Treat areas of high alkalinity.
10 NORTH DEARBORN STREET
8TH FLOOR
CHICAGO, ILLINOIS 60602
2.4 CLEANING
1.4 INSTALLATION, GENERAL
A. Perform the following operations immediately after completing installation.
1. Remove visible adhesive, seam sealer, and other surface blemishes using cleaner recommended by carpet
manufacturer.
2. Remove protruding yarns from carpet surface.
3. Vacuum carpet using commercial machine with face-beater element.
A. General: Comply with wall coverings manufacturers' written installation instructions applicable to products and
applications indicated, except where more stringent requirements apply.
SPECIFICATIONS
B. Match pattern 72 inches above finish floor.
2.5 PROTECTION
C. Install seams vertical and plumb at least 6 inches from outside corners and 3 inches from inside corners. No horizontal
seams.
A. General: Comply with CRI 104, Section 15: "Protection of Indoor Installation."
D. Remove air bubbles, wrinkles, blisters, and other defects.
B. Provide final protection and maintain conditions, in a manner acceptable to manufacturer and Installer, that ensure
carpet is without damage or deterioration at the time of Substantial Completion.
E. Trim edges for color uniformity, pattern match, and tight closure at seams and edges. Butt seams.
PROJECT NUMBER:
0213
DRAWING SCALE:
AS NOTED
SHEET NO:
A14