CITY OF CHICAGO DEPARTMENT OF CONSTRUCTION AND PERMITS GENERAL BUILDING REQUIREMENTS Per Chicago Zoning Ordinance(CZO) and Chicago Building Code (CBC) 2004 Edition Item Issue Chapter/Article Ordinance Requirmnt Actual Requirmnt N/A Location/ Sheet No. Agency/ Test No. Remarks CIVIC FEDERATION 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 PART 1- ZONING REQUIREMENTS PART 2 - BUILDING REQUIREMENTS Occupancy Classification(s) 3 (13-56) page 115 E E - A1 - Business Height and Area Limitations 5 (13-48) page 323 - - N/A - - No Change to Building - - N/A - - a)Exceptions to Area Limitations 5(13-48-090)pg.325 b)Mixed Occupancy Buildings 5(13-48-100)pg. 326 Types of Construction 6(13-60) page 329 Mixed Occupancy Separations 3(13-56-280)pg.118 Occupant Load 3(13-56-320) Req.Hrs of Fire Resistance 6(13-60-100)pg. 330 Exterior Bearing Walls - - N/A - - I-A I-A - A1 - - - N/A - - 1/100 Sq. Ft. 48 - A7 - Business: 4,858/100 = 48 persons max. allowed Table 6(13-60-100) NC NC N/A - - No Change to Building Exterior -Nonbearing Walls Table 6(13-60-100) NC NC N/A - - No Change to Building Interior Bearing Walls Table 6(13-60-100) NC NC N/A - - No Change to Building Interior Nonbearing Walls Table 6(13-60-100) 1 Hr 1 Hr - A10 - Project Complies Columns Table 6(13-60-100) NC NC N/A - - No Change to Building Columns Supporting Roofs Only Table 6(13-60-100) NC NC N/A - - No Change to Building Beams Table 6(13-60-100) NC NC N/A - - No Change to Building Beams Supporting Roofs Only Table 6(13-60-100) NC NC N/A - - No Change to Building Floor Construction Table 6(13-60-100) NC NC N/A - - No Change to Building Roof Construction Table 6(13-60-100) NC NC N/A - - No Change to Building Elevator Framing 6(13-60-130)pg.331 NC NC N/A - - No Change to Building Driveways and Loading Spaces 6(13-60-210)pg. 332 - - N/A - - No Change to Building Fire - Resistive Requirements 7(15-8) page 335 No Change to Building a)Fire Walls - Construction 7(15-8-010)page 335 - - N/A - - No Change to Building b)Parapets 7(15-8-100)p335 - - N/A - - No Change to Building c)Stairway Enclosures 7(15-8-140)pg.337 - - N/A - - No Change to Building d)Elevator Enclosures 7(15-8-150)pg 337 - - N/A - - No Change to Building e)Enclosures of Heating Rooms 7(15-8-190)pg 338 - - N/A - - No Change to Building f)Enclosures of Wells & Chutes 7(15-8-170)pg 338 - - N/A - - No Change to Building f1)Enclosures of pipe shafts and ducts 7(15-8-160)pg 338 - - N/A - - No Change to Building - N/A - - No Change to Building - A7 - Flame Spread of 26 - 75 g)Other Enclosures 7(15-8-240)pg.339 h)Interior Wall and Clg.Finishes 7(15-8-380)pg.341 I)Storage Rooms over 100sq.ft 7(15-8-240)(b)pg.339 - - NA A8 - No Change to Building 2.11 Fire - Resistive Materials and Construction 7(15-12)page 348 - - NA - - No Change to Building 2.12 Accepted Engineering Practice 7(15-12-050) - - NA - - No Change to Building 2.13 Fire Protection Equipment 9(15-16) page 361 - - - - - No Change to Building a)Sprinkler Systems 9(15-16-010)pg 362 - - - FP1 - See Engineering Drawings b)Special Requirements 9(15-16-030)pg 362 - - - - - No Change to Building - - - No Change to Building NR Class 2 Class 2 GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM PROJECT DIRECTORY Tenant: Civic Federation 177 N. State Street, Suite 400 Chicago, Illinois 60601 (312) 201-9041 Architect: Garnett Architects, LLC 140 South Dearborn, Suite 410 Chicago, Illinois 60603 (312) 447-0747 NEW AREAS OF WORK General Contractor: Bear Construction 1431 North Western Ave. Chciago, IL 60622 (773) 360-7570 PART 3 - EXIT REQUIREMENTS Types of Exits 10(13-160-040)pg 388 Existing Minimum Number of Exits 10(13-160-050)pg 388 2 Per Floor 2 - A8 - See Drawings Travel Distance to Exits 10(13-160-110)pg 389 150' 99' - A8 - Maximum Travel Distance Indicated On Plan a)Increases Permitted 10(13-160-150)pg 390 50% 50% - - - Standard Sprinkler System b)Dead End Corridor 10(13-160-160)pg.390 - Existing 75' 75' A8 Doors = 60 / Unit See Drawings - A8 Capacity of Exits 3(13-84-180)pg 136 Minimum Width of Exits 10(13-160-220)pg 391 36" wide doors See Drawings - Swing of Exit Doors 10(13-160-250)pg 391 As Required See Drawings - Hardware 10(13-160-260)pg 392 As Required See Drawings - Landings 10(13-160-310)pg 394 - - N/A Handrails 10(13-160-320)pg 394 - - - Exisiting Condition A8 - Entrance/Exit doors 36"-72" A8 - Doors swing in the direction of egress - Keyless in direction of egress - - Existing Condition N/A - - Existing Condition Construction 10(13-160-330)pg 394 Existing NC N/A - - Existing Stairs Enclosures 7(15-8-140)pg 337 Existing Existing N/A - - Existing Stairs Head Room 10(13-160-350)pg 394 7'-0" 8'-0" N/A - - Existing Stairs Building Representative: REDICO Real Estate Development and Investment Company One Towne Square, Suite 1600 Southfield, Michigan 48076 LIST OF DRAWINGS PART 4 - ACCESSIBILITY REQUIREMENTS New Construction IAC 400.310 - - N/A - - Accessible Route IAC 400.310(a) - - N/A A8 - See Drawings - Project Complies Areas of Rescue Assistance IAC 400.310(b) - - N/A - - No Change to Building Curb Ramps IAC 400.310 (d) - - N/A - - No Change to Building Ramps IAC 400.310 (e) - - N/A - - No Change to Building Stairs IAC 400.310 (f) - - N/A - - No Change to Building Elevators IAC 400.310 (g) - - N/A - - No Change to Building Doors IAC 400.310(j) 36" 36" N/A - - Project Complies Accessible Entrance IAC 400.310(k) - N/A - - Project Complies Drinking Fountain IAC 400.310 (l) Hi - Lo - N/A - - Available in common corridor Toilet Rooms IAC 400.310(n) - - N/A - - No Change to Building Controls & Operating Mech. IAC 400.310(r) Reach Range - - - - Project Complies Alarms IAC 400.310(s) - - - - - New Will Be Synchronized Detectable Warnings at Stairs IAC 400.310(t) - - - - - No Change to Building Signage IAC 400.310(u) - - - - - Existing Signage Complies Telephones IAC 400.310(v) - - - - - No Change to Building Business and Mercantile IAC 400.320(h) - - - - - Project Complies Alteration IAC 400.510 (b) (1) - - - - - Project Complies 1 8TH FLOOR KEY PLAN SCALE: NORTH NOT TO SCALE ENERGY CONSERVATION CODE COMPLIANCE STATEMENT PROJECT LOCATION PART 6: VENTILATION/FURNACE Outside Air Intake 28(13-176-090) - - N/A M1 - Project Complies Minimum Amount of Air 28(13-176-070) 50 CFM - N/A M1 - Project Complies Ductwork 28(13-176-160) Sheet Metal - - M1 - Project Complies Transfer Ducts 28(13-176-170)(e) 5'-0" - - M1 - Project Complies Type K Copper - N/A M1 - Project Complies Brazed - N/A M1 - Project Complies See Comment - N/A M1 - Project Complies MEFP Consultants: Kent Consulting Engineers 2015 Spring Road, Suite 240 Oak Brook, Illinois 60523 (630) 684-0234 A1 A1.2 A2 A3 A4 A5 A6 A7 A8 A9.1 A9.2 A10 A11 A12 A13 A14 PROJECT INFORMATION SCHEDULE LEGEND SHEET 8TH FLOOR DEMOLITION PLAN 8TH FLOOR ARCHITECTURE PLAN 8TH FLOOR REFLECTED CEILING PLAN 8TH FLOOR POWER AND COMMUNICATION PLAN 8TH FLOOR FINISH PLAN 8TH FLOOR FURNITURE PLAN ELEVATIONS ELEVATIONS PARTITION TYPES AND DETAILS MILLWORK DETAILS DOOR TYPES AND DETAILS SPECIFICATIONS SECIFICATIONS M1 M2 M3 E1 E2 E3 E4 P1 P2 FP1 MECHANICAL NOTES AND SCHEDULES MECHANICAL DEMOLITION PLAN MECHANICAL PLAN ELECTRICAL SPECIFICATIONS ELECTRICAL POWER PLAN ELECTRICAL LIGHTING PLAN EMERGENCY LIGHTING PLAN PLUMBING NOTES PLUMBING PLAN FIRE PROTECTION I certify that I am a Registered Energy Professional (REP). I also certify that to the best of my professional knowledge and belief that the attached plans for 10 North Dearborn Street fully comply with the requirements of Chapter 18-13, Energy Conservation, of the Municipal Code of Chicago, except 18-13-303.1. Signed______________________________________Date:03/13/15 PART 7: REFRIGERATION Pipe Size and Material Grade 28(13-192-430 Means of Joining Piping Air Stream Requirements 28(13-192-380) Size/Location of Safety Valve 28(13-192-520 to 560) Size/Location of Vent Line 28(13-192-670) High Side - N/A M1 - Project Complies Relief Valve - N/A M1 - Project Complies NO. 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION This is to certify that these drawings were prepared under my supervision and that to the best of my knowledge, comply with the The City of Chicago Building Code. PART 8: PLUMBING Plumbing Fixture Count 18-29-403 - - - P1 - Project Complies Water Heater 18-29-503-504 - - - P1 - Project Complies Plumbing Fixture Schedule 18-29-401 to 425.4 - - - P1 - Project Complies Material for water,waste & vent 18-29-702 - - - P1 - Project Complies Isometric Piping Diagrams 18-29-105 - - - P1 - Project Complies ______________________________________ Jack M. Janowiak, License #001-014742 Licensed Architect, State of Illinois, Expires 11/30/2016 Sheets: A1 - A14 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 Date: 03/13/15 PART 9: ELECTRICAL Single Line Drawing - - - E1 - Project Complies Emergency Source 18-27-700.5 - - - E1 - Project Complies Non Utility Source of Power 18-27-700.6 - - - E1 - Project Complies PROJECT INFORMATION 2 LOCATION PHOTO SCALE: NOT TO SCALE NORTH PROJECT NUMBER: 0213 DRAWING SCALE: AS NOTED SHEET NO: A1 FINISH SCHEDULE FINISH SCHEDULE DOOR HARDWARE SCHEDULE HARDWARE SET NO. 1 - OFFICE LOCKSET WALL FINISHES: P 1 PAINT P-1: (GENERAL) BENJAMIN MOORE, #2124-70, DISTANT GRAY P 2 PAINT P-2: (PRIVATE OFFICE ACCENT) BENJAMIN MOORE, #CSP-105 SMOKE AND MIRRORS P 3 PAINT P-3: (BOARDROOM ACCENT) SHERWIN WILLIAMS, #SW0038 LIBRARY PEWTER SD-4 P 4 WC 1 WC 2 WALLCOVERING WC-2: MDC STYLE: LIBRARY, NEWSPRINT PATTERN: PAZ6405/4543 WALL BASE: B 1 TYPICAL VINYL BASE, 2.-1/2" JOHNSONITE #08 ICICLE WITH 275 VEGETATE B 2 TYPICAL VINYL BASE, 2-1/2" ALLSTATE, #D48 B 3 TYPICAL VINYL BASE, 2-1/2" JOHNSONITE #281 GRIZZLY WG B 4 TYPICAL VINYL BASE, 2-1/2" JOHNSONITE #29 MOON ROCK FLOOR FINISHES: CARPET 1: (GENERAL CARPET) SHAW CONTRACT GROUP STYLE: HAZE TILE 5T037 COLOR: SMOKE 37557 CONTACT: JANET MICELI C. 773.771.0916 GL-1 CPT 1 CLG1: ACT-1, ACOUSTIC 2X2 OPEN OFFICE CEILING: 9 ARMSTRONG, OPTIMA, 16 " SQUARE TEGULAR, 3251 , WHITE, 4" AXIOM TRIM EDGE. PROVIDE 9/16" GRID GR-1 AT ACT-1 LOCATIONS: CEILING GRID GR-1: ARMSTRONG SILHOUETTE 81" REVEAL. COLOR: WHITE. CLG2: ACT-2, 2X2 ACOUSTIC TYPICAL CEILING, WHITE: 9 ARMSTRONG, ULTIMA, 16 " BEVELED TEGULAR, 1912, WHITE CEILING GRID GR-2: ARMSTRONG SILHOUETTE 81" REVEAL. COLOR: WHITE. CLG3: ACT-3, 2X4 ACOUSTIC BOARDROOM CEILING, WHITE: 9 ARMSTRONG, ULTIMA, 16 " BEVELED TEGULAR, 1915, WHITE CEILING GRID GR-2: ARMSTRONG SILHOUETTE 81" REVEAL. COLOR: WHITE. HARDWARE SET NO. 3 - STOREROOM LOCKSET HARDWARE SET NO. 4 - CLOSET PIVOT, PAIR 2 - HALF DUMMY TRIM: SCHLAGE, L0170, LEVER 07, ROSE A, BHMA 630 2 SETS - PIVOT HINGES: RIXSON, #370 (TOP) #340 (BOTTOM) 2 - CONCEALED OVERHEAD STOP: ABH, 4024 (36 IN. DOOR) OR 4023 (<35 IN. DOOR), BHMA 630 2 - ROLLER LATCH W/ ANGLE STOP: ROCKWOOD, 593, BHMA 630 HARDWARE SET NO. 5 - CARD READER ENTRY HARDWARE SET NO. 6 - CARD READER ENTRY 1 - ELECTRIC HINGE: STANLEY CEFBB179 4 1/2" X 4 1/2", BHMA 630 3 - BUTT HINGES: STANLEY, FBB 179 4 1/2 X 4 1/2, BHMA 626 EQ # F2 F3 F4 F5 WOOD FLOOR (RECEPTION) DUCHATEAU VERNAL COLLECTION VERNAL COMO, EUROPEAN OAK CONTACT: SANDRA MOAD T. 619.793.5899 PLASTIC LAMINATE 1: FORMICA COLOR CORE 2 NEW WHITE 7223C-90 GLOSS FINISH EQ 3 EQ-3 COPIER BY OWNER (NETWORK) EQ 4 EQ-4 TV BY OWNER, INSTALLED BY GC EQ 5 EQ-5 POSTAGE MACHINE BY OWNER F3 - LINEAR SUSPENSION (OPEN OFFICE) CORELITE, JAYLUM SUSPENDED, FROSTED LENS J2-SL-2N5-AC18-TS-12 F4 - LED PENDANT:OPEN OFFICE IMPACT ARCHITECTURAL LIGHTING, bul.it.LED, P3316.LED 35HI SB BKPC, 16" DIA., 3500K, SATIN BLACK, BLACK POWER CORD AND CANOPY F5 - LINEAR SUSPENSION (8' WALL WASH) ALW, NOVENTA NV3.5S- 8'- T5S2-DIM-BK F7 F7 - LINEAR SUSPENSION (8' REDCEPTION) ALW, NOVENTA NV3.5- 8'- T5S2-DIM-BK F8 - UNDERCABINET LIGHTING, MERCURY LIGHTING, SERIES MUC1, MINI UNDERCABINET. LENGTHS AS NOTES BELOW. F8A - 36" LENGTH MUC1-121-T5-UG-A-120V-LWW PLASTIC LAMINATE 2: FORMICA WHITE 9449-90 GLOSS FINISH EQ-2 MICROWAVE, BY GC GE, JES1451DSWW, WHITE MICROWAVE-COUNTERTOP 12.5"H X 21-7/8"W X 16-3/8"D F1 - 2X4 LAY-IN FLUORESCENT LIGHT FIXTURE, CORELITE, CLASS R2, FROSTED PRISMATIC LENS R2-WL-2N5-24-TI-CP (CHICAGO PLENNUM) F6 - LINEAR SUSPENSION (6' SUSPENDED) ALW, NOVENTA NV3.5S- 6'- T5S2-STD-BK F8 EQ-1 REFRIGERATOR BY GC WHIRLPOOL, WRF535SMBW 25CF, WHITE 70"H X 36"W X 35.5"D GC TO PROVIDE WATER LINE EQ 2 F6 MILLWORK FINISHES: EQUIPMENT SCHEDULE LIGHT FIXTURE SCHEDULE F2- 2X2 LAY-INFLUORESCENT LIGHT FIXTURE,CORELITE, CLASS R2, FROSTED PRISMATIC LENS R2-WL-2N5-22-TI-CP (CHICAGO PLENNUM) 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM 2 - CONCEALED CLOSERS: LCN, 3130 SERIES, POWDER COAT EQ 1 F1 GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN CLG4: DRYWALL CEILING, PAINTED. VINYL TILE ARMSTRONG EXCELON STYLE: CHAMPION SQUARE COLOR: 51973 MONO WHITE SIZE: 12"X12" THICKNESS: 1/8" CONTACT: JAMIE PIKOLAS T. 717.396.4170 WD-2 LEVER 07, ROSE A FLOORING TRANSITION TARGETS CEILING SCHEDULE LUXURY VINYL TILE BENTLEY TERRENE COLLECTION STYLE: PBEAM06X36 COLOR: BREEZY 800585 SIZE: 6" X 36" THICKNESS: .118" CONTACT: BETH GHADIMI C.312.965.3345 PL-3 1/4" CLEAR TEMPERED GLASS 1 VCT CARPET 3: (RECEPTION) FLOR STYLE: RAKE ME OVER COLOR: GRAPHITE 21-1050-07 CONTACT: KATELIN CONNEALY T.312.923.8189 PL-2 HARDWARE SET NO. 2 - MEETING ROOM LATCHSET LEVER 07, ROSE A CARPET 2: (PRIVATE OFFICE CARPET) SHAW CONTRACT GROUP STYLE: HAZE TILE 5T038 COLOR: DELICATE 37515 CONTACT: JANET MICELI C. 773.771.0916 PL-1 SOLID SURFACE (BOARDROOM) DIRESCO COLOR: SUPREME WHITE NUMBER: S100, POLISHED CONTACT: GLAZING: PAINT P-4: (ACCENT COPY AREA) BENJAMIN MOORE, #CSP-115 BARNWOOD WALLCOVERING WC-1: RECEPTION MAHARAM, HERRING 399614 COLOR:006 LEVER 07, ROSE A WALL FINISHES: EQ 6 EQ-6 DISHWASHER BY GC WHIRLPOOL GOLD SERIES, WDT720PADW, WHITE 34"H X 23 3 4"W X 24.5"D GE TO PROVIDE WATER LINE EQ 7 EQ-7 ELECTRIC STAPLER BY OWNER EQ 8 EQ-8 PAPER SHREDDER BY OWNER EQ 9 EQ-9 PRINTER (PERSONAL) BY OWNER EQ 10 EQ10 COFFEE MAKER BY OWNER EQ 11 EQ11 ELECTRIC TEA POT BY OWNER EQ 12 EQ12 FAX MACHINE BY OWNER PLUMBING FIXTURE SCHEDULE SINK 1: (UNDERMOUNT) ELKAY, ELUHAD2816, STAINLESS STEEL UNDERMOUNT SINK KOHLER, PURIST, PULL-OUT KITCHEN FAUCET, K-7505. PROVIDE UNDER-COUNTER WATER FILTER SYSTEM: EVERPURE, QL3B SINGLE HEAD EV9259-24 W/ OW4-PLUS FILTER CARTRIDGE EV9635-01; ELKAY LK1110 F8B - 48" LENGTH MUC1-128-T5-UG-A-120V-LWW PLASTIC LAMINATE 3: ARPA TEX FINISH 3317 F9 WOOD VENEER 2: DOOR MANUFACTURERS STANDARD WOOD VENEER. PLAIN SLICED WALNUT. STANDARD DARK STAIN TO MATCH ARCHITECT'S SAMPLE. F10 F9 - SQUARE LED DOWNLIGHT COOPER LIGHTING BY EATON, PORTFOLIO LDSQ4ACP-13D010TE-ESQ4A13835CP-4LSQ1H (CHICAGO PLENUM) F10 - SQUARE LED LENS WALL WASH COOPER LIGHTING BY EATON, PORTFOLIO LDSQ4ACP-13D010TE-ESQ4A13835CP-4LSQLWW1H (CHICAGO PLENUM) WALL TILE: SD-3 SOLID SURFACE (RECEPTION DESK) DIRESCO COLOR: PURE WHITE NUMBER: A250, POLISHED CONTACT: F12 b SOLID SURFACE (RECEPTION DESK) CAESARSTONE CLASSICO COLLECTION COLOR: CONCRETE NUMBER: 2003 SOLID SURFACE (CAFE COUNTER) CAESARSTONE CLASSICO COLLECTION COLOR: PURE WHITE NUMBER: 1141 D F11 - RECESSED FLUORESCENT FIXTURE (26 FEET LENGTH) NULITE, REGOLO 6 GRID SERIES RG6-2T5-S-ST-D-26' NO. 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION F12 - DECORATIVE PENDANT (17" WIDTH) LIGHTOLOGY, CASTORE, ART2187, WHITE, WHITE BODY, 150W INCANDESCENT. #0112SU-CASTORE-017I1-WHWH "b" LOWER CASE SUBSCRIPT AT LIGHT FIXTURE AND CORRESPONDING SWITCH INDICATES SWITCHING S SD-2 F11 WALL MOUNTED TOGGLE SWITCH S SD-1 GLASS TILE 1: BACKSPLASH L'ANTIC COLONIAL TREASURES NUDE NEPAL MOON SIZE: 19X29 MOSAIC WALL MOUNTED DIMMER SWITCH 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 SCHEDULES 3 S GT-1 WALL MOUNTED 3-WAY SWITCH PROJECT NUMBER: CEILING HEIGHT TARGET, DISTANCE FROM FINISHED FLOOR AS INDICATED 0213 DRAWING SCALE: NONE SHEET NO: A1.2 ABBREVIATIONS A WALL-MOUNTED OR FURNITURE PANEL-MOUNTED DUPLEX POWER RECEPTACLE PARTITION TYPE A, TO 6 INCHES ABOVE CEILING B WALL-MOUNTED QUADRAPLEX POWER RECEPTACLE PARTITION TYPE 'B', DEMISING TO SLAB ABOVE WALL-MOUNTED DUPLEX RECEPTACLE, DEDICATED CIRCUIT C PARTITION TYPE 'C', FURRING TYPE, 6 INCHES ABOVE CEILING WALL-MOUNTED GROUND FAULT CIRCUIT INTERUPTER DUPLEX GFI 4 COLUMN TARGET OFFICE 1750 ROOM NUMBER TARGET 1750 A 1 B PUSH-BUTTON DOOR RELEASE 44" DOOR TARGET DOOR NUMBER HARDWARE SET DOOR TYPE 1 A9 ELEVATION TARGET DRAWING NUMBER SHEET NUMBER 1 A11 SECTION TARGET DRAWING NUMBER SHEET NUMBER 2 A9 DETAIL TARGET DRAWING NUMBER SHEET NUMBER 4 MOUNTING HEIGHT IN INCHES ABOVE FINISHED FLOOR GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN WALL-MOUNTED TELEPHONE AT 48" TO TOP OF TELEPHONE W MILLWORK ITEM A9 WALL-MOUNTED KEY CARD DEVICE KEYNOTE TARGET 1 2 K 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM WALL OR FURNITURE PANEL-MOUNTED TELE-DATA RECEPTACLE. GC TO PROVIDE CONDUIT AND PULL STRING. FLOOR-MOUNTED POKE-THROUGH WITH POWER AND TELE-DATA DEVICES. FLUSH DEVICE. 3 T FLOOR-MOUNTED TELE-DATA AND POWER FEEDS TO FURNITURE PANEL (NOT USED) P CONTROL JOINT TV TELEVISION RECEPTACLE W/ CABLE TO BUILDING SOURCE FINISH SYMBOLS WC 1 WALL FINISH TARGET WC - WALLCOVERING P - PAINT CT - CERAMIC TILE GL - GLASS GT - GLASS TILE MW - MILLWORK PANEL CPT 1 FLOOR FINISH TARGET CPT - CARPET VCT - VINYL COMPOSITION TILE CER - CERAMIC TILE RBR - RUBBER FLOORING TZT - TERRAZZO TILE EX - EXISTING TO REMAIN CPT 1 FLOORING TRANSITION TARGETS 1 VCT LIGHT SWITCH CARD READER LOCATION THERMOSTAT (NEVER DIRECTLY ABOVE LIGHT SWITCHES) - WALL MOUNTED PHONE TO BE MOUNTED WITH TOP OF PHONE AT APPLICABLE REACH HEIGHT AS PER IAC 400.310v NO. 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION 3'-6" CONTROL JOINT AT PARTITION OR SOFFIT CJ SIMPLEX POWER RECEPTACLE 4'-6" WINDOW MULLION CENTERLINE EQUIPMENT TARGET 4'-0" M EQ 3 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 1'-3" CENTERLINE WALL-MOUNTED TELE-DATA AND POWER FEEDS TO FURNITURE PANEL FRONT REACH* CL T P 4'-0" ACOUSTICAL ADJUSTABLE ALUMINUM APPROXIMATE ARCHITECTURAL BOARD BUILDING BLOCK BLOCKING BOTTOM CABINET CEMENT CERAMIC CORNER GUARD CONTROL JOINT CENTERLINE CEILING CLEAR CASED OPENING COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS COUNTER CENTER DOUBLE DETAIL DIAMETER DIMENSION DOWN DOOR OPENING DOOR DRAWER DRAWING EAST EACH ELEVATION ELECTRICAL ELEVATOR EMERGENCY ENCLOSURE ELECTRICAL PANELBOARD EQUAL EQUIPMENT ELECTRIC WATER COOLER EXISTING EXPANSION EXTENSION FIRE ALARM FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINQUISHER CABINET FIRE HOSE CABINET FINISH FLOOR FLUORESCENT FIREPROOF FULL SIZE FOOT OR FEET FURRING GALVANIZED GRAB BAR GLASS GROUND GYPSUM GYPSUM BOARD HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT INSULATION INTERIOR JOINT LAMINATE LAVATORY LOCKER MAXIMUM MEMBRANE METAL MANUFACTURER MINIMUM MIRROR MISCELLANEOUS MASONRY OPENING MOUNTED NORTH NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE PLATE PLASTIC LAMINATE PLASTER PLYWOOD PAIR POINT PARTITION QUARRY TILE RADIUS ROOF DRAIN REFERENCE REFRIGERATOR REINFORCED REQUIRED RESILIENT ROOM ROUGH OPENING SOUTH SOLID CORE SCHEDULE SOLID SURFACE SECTION SHELF SHEET SIMILAR SPECIFICATION SQUARE STAINLESS STEEL STANDARD STEEL STRUCTURAL SUSPENDED SYMMETRICAL TREAD TO MATCH EXISTING TOWEL BAR TELEPHONE TERRAZZO TONGUE & GROOVE THICK TELEVISION TYPICAL UNFINISHED UNLESS NOTED OTHERWISE VERTICAL VESTIBULE WEST WITH WATER CLOSET WOOD WITHOUT WATERPROOF WAINSCOT WEIGHT ELECTRICAL SYMBOLS SIDE REACH* ACOUS. ADJ. AL. APPROX. ARCH. BD. BLDG. BLK. BLKG. BOT. CAB. CEM. CER. C.G. C.J. CL CLG. CLR. C.O. COL. CONC. CONN. CONSTR. CONT. CNTR. CTR. DBL. DTL. DIA. DIM. DN. D.O. DR. DWR. DWG. E. EA. EL. ELEC. ELEV. EMER. ENCL. E.P. EQ. EQPT. E.W.C. EXIST. EXPAN. EXT. F.A. F.D. F.E. F.E.C. F.H.C. FIN. FL. FLUOR. F.P. F.S. FT. FURR. GALV. G.B. GL. GND. GYP. GYP.BD. HDWD. HDWR. H.M. HORIZ. HR. HT. INSUL. INT. JT. LAM. LAV. LKR. MAX. MEMB. MTL. MFR. MIN. MIR. MISC. M.O. MTD. N. N.I.C. NO. NOM. N.T.S. O.C. OPNG. OPP. PL. P. LAM. PLAS. PLYWD. PR. PT. PTN Q.T. R. R.D. REF. REFR. REINF. REQ. RESIL. RM. R.O. S. S.C. SCHED. SD. S SECT. SH. SHT. SIM. SPEC. SQ. S.S. STD. STL. STRL. SUSP. SYM TRD. T.M.E. T.B. TELE. TZ. T.& G. THK. T.V. TYP. UNF. U.N.O. VERT. VEST. W. W/ W.C. WD. W/O WP. WSCT. WT. ARCHITECTURE SYMBOLS 4'-6" MATERIAL SYMBOLS LEGEND *ALL CONTROLS AND OPERATING MECHANISMS TO FALL WITHIN FRONT AND SIDE REACH RANGES AS PER IAC 400.310r 1 ELEVATION @ TYPICAL DEVICE MOUNTING HEIGHTS PROJECT NUMBER: SCALE: DRAWING SCALE: 3"=1'-0" 0213 AS NOTED SHEET NO: A2 C2 B1 5 GARNETT ARCHITECTS, LLC 6 ARCHITECTURE . PLANNING . INTERIOR DESIGN 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM 4 GENERAL NOTES A. ARCHITECTURAL ITEMS INDICATED WITH A DOTTED LINE SHALL BE REMOVED. ARCHITECTURAL ITEMS INDICATED WITH FILLED WALLS AND SOLID LINES SHALL REMAIN. SEE SHEET A2 FOR LEGEND. 6 B. THE G.C. SHALL VERIFY EXISTING FIELD CONDITIONS. CONFLICTS OR DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION. NO CHANGE ORDER WILL BE APPROVED DUE TO FIELD CONDITIONS THAT ARE EVIDENT PRIOR TO DEMOLITION. 1 C. ARCHITECTURE TO REMAIN SHALL BE PROTECTED FROM DAMAGE. ANY DAMAGE SHALL BE REPAIRED AT NO ADDITIONAL COST TO THE TENANT. 3 D. SALVAGE LIFE SAFETY DEVICES, FIRE EXTINGUISHERS & CABINETS FOR REUSE. 6 E. SALVAGE DOORS, FRAMES, SIDELIGHTS AND HARDWARE FOR REUSE. CATALOG SALVAGED ITEMS FOR REUSE. 7 4 4 F. REMOVE ELECTRICAL OUTLETS AND DEVICES AS INDICATED AND ON PARTITIONS/WALLS TO BE DEMOLISHED. G. REFER TO ENGINEERING DRAWINGS FOR ADDITIONAL DEMOLITION INFORMATION. 3 H, REFINISH EXISTING DRYWALL TO REMAIN. KEYNOTES 1 3 1. REMOVE EXISTING DRYWALL AND FURRING. PROTECT EXISTING MASONRY WALL DURING CONSTRUCTION. 2. REMOVE ELECTRICAL DEVICE AND OUTLETS AS INDICATED ON EXISTING PARTITIONS TO REMAIN. 3 3. REMOVE ALL UNUSED, NONESSENTIAL CEILING ELEMENTS INCLUDING BUT NOT LIMITED TO DUCTWORK, CONDUIT, AND PIPES FROM THE PROPOSED OPEN CEILING AREA. REFER TO SHEET A5 FOR PROPOSED AREA. 6 4. REMOVE EXISTING DRYWALL FROM COLUMNS, TYPICAL. 2 5. REMOVE EXISTING DEVICES AND CONDUIT FROM COLUMNS, TYPICAL. 3 6. SALVAGE EXISTING DOORS, FRAMES, AND HARDWARE. COORDINATE STORAGE WITH LANDLORD. 5 5 2 3 3 1 NO. 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION 1 3 2 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 1 8TH FLOOR DEMOLITION PLAN A B C D E F PROJECT NUMBER: NORTH SHEET NO: 0213 DRAWING SCALE: 1/4" = 1'-0" 0 1' 2' 4' 8' A3 C2 B1 SERVER/ STORAGE 813 CAFE 814 OFFICE 812 5 1 A9.1 GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN M 7'-11" 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM 4 B 2'-0" 7'-11" CLOSET 800.1 6'-5" RECEPTION 800 1 GENERAL NOTES A. ALL PARTITIONS SHALL BE TYPE "A" UNLESS NOTED OTHERWISE. SEE SHEET A10 FOR DETAILS. A B. GENERAL CONTRACTOR IS TO NOTIFY ARCHITECT WHEN PARTITION LAYOUT MAY BE REVIEWED BEFORE PLACEMENT OF METAL RUNNERS AND STUDS. C. ALL PARTITIONS SHALL RECEIVE PAINT P-1 AND WALL BASE B-1, UNLESS NOTED OTHERWISE. 8'-2" 22'-10" 8'-2" 3 A9.2 2 A9.1 CORRIDOR 811 C A 4'-5" C 2 A9.2 4 M1 19'-7" 11'-7" 8'-8" 5 8'-8" 14'-7" B 4'-0" D1 B F. ALL HORIZONTAL SOFFIT PLANES ARE TO BE PAINTED WHITE, UNLESS NOTED OTHERWISE. VERTICAL PLANES ARE TO MATCH ADJACENT WALL SURFACES, UNLESS NOTED OTHERWISE REFER TO ELEVATIONS FOR ADDITIONAL INFORMATION. 12'-9" OFFICE 810 6'-6" G. FINISH TARGETS ARE FOR GENERAL INFORMATION. FOR EXACT LOCATIONS OF FINISHES SEE ELEVATIONS, SCHEDULES AND DETAILS. 3 B 1'-6" 1'-6" 4'-0" A9 2'-0" D1 B 10'-0" 8'-10" E. THE G.C. SHALL PREPARE WALL, FLOOR AND CEILING SURFACES AS REQUIRED AND RECOMMENDED BY MANUFACTURER TO RECEIVE NEW FINISHES AS INDICATED ON PLAN, INCLUDING FLOOR PREP. C 3'-6" 25'-8" C 11'-4" A1 3 A9.1 D. ALL FLOORING SHALL BE CPT-1, UNLESS NOTED OTHERWISE. VINYL BASE SHALL BE STRAIGHT TYPE AT CARPET AND COVE TYPE AT VCT. DO NOT INSTALL WALL BASE TO MILLWORK. B C H. FLOORING TRANSITIONS AT DOOR OPENINGS SHALL OCCUR AT THE DOOR CENTERLINE. SEE FINISH SPECS FOR COLOR. SEE FLOOR FINISH TRANSITION DETAILS AT SHEET A16. 7'-8" 4'-5" FEC M 4'-5" 4'-3" 1'-6" 2'-0" OFFICE 809 J. FIRE EXTINGUISHER, FIRE HOSE CABINETS, AND ACCESS PANELS SHALL BE PAINTED TO MATCH ADJACENT WALL COLOR IN ALKYD ENAMEL PAINT. DO NOT PAINT METAL CABINETS WITH LATEX WALL PAINT. 10'-1" 4 A9.1 B B 1 A9.2 5'-4" E K. FLOORING MATERIAL SHALL BE INSTALLED UNDER NEW MILLWORK. 5'-3" BOARDROOM 801 L. REPAIR/ REFINIISH ALL DAMAGED EXISTING DRYWALL CONDITIONS TO LIKE NEW CONDITION. CORRIDOR 818 A1 BREAKOUT AREA 815 COPY AREA 816 M. FUR OUT ALL EXISTING COLUMNS. PROVIDE DETAIL TYPE "D" ON SHEET A10. KEYNOTES 8'-0" 6'-11" B 1. PROVIDE COAT CLOSET MILLWORK PER DETAIL 1/ A11. M MIN 39'-1" 5 A9.1 2 OPEN OFFICE 817 M 4'-0" A1 7'-8" 26'-6" OFFICE 808 B 18'-5" B 10'-4" 11'-7" 13'-11" B B B 11'-5" 11'-10" 11'-7" 14'-5" - E NO. 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 1 8TH FLOOR ARCHITECTURE PLAN A B 802 OFFICE 803 OFFICE C 804 OFFICE 805 OFFICE D 806 OFFICE E 807 OFFICE F PROJECT NUMBER: NORTH SHEET NO: 0213 DRAWING SCALE: 1/4" = 1'-0" 0 1' 2' 4' 8' A4 C2 B1 SERVER/ STORAGE 813 CAFE 814 OFFICE 812 5 X A10 EXISTING GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN 8'-6" F9 F9 RECEPTION 800 F9 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM 4 E OPEN CEILING F1 CLOSET 800.1 GENERAL NOTES A. CEILING HEIGHT 8'-6" AFF U.N.O. B. THIS DRAWING INDICATES THE LOCATION OF FIXTURES AND SWITCHES. REFER TO ENGINEER'S DRAWINGS FOR CIRCUIT DESIGN, SPECIFICATIONS AND SCHEDULES. F1 F10 C. SEE ENGINEERING DRAWINGS FOR LOCATIONS OF EXIT SIGNS AND EMERGENCY FIXTURES. PROVIDE EXIT SIGNS AS REQUIRED BY THE LOCAL FIRE OFFICIAL UPON REVIEW. 1 A10 1 CORRIDOR 811 D. TYPICAL CEILING TO BE CLG2 UNLESS NOTED OTHERWISE. REFER TO CEILING SCHEDULE ON SHEET A1.2 F10 F5 E. G.C. SHALL REVIEW LOW-HANGING DUCTWORK AND PIPING, ETC. TO CONFIRM CEILING RESTRICTIONS. ANY CONFLICT OR INTERFERENCE SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR REVIEW. F7 F8B 8'-6" F8B 8'-6" E F8A F2 F2 F2 F. MULTIPLE SWITCH LOCATIONS SHALL BE GROUPED TOGETHER WITH A SINGLE COVER PLATE. SEE LEGEND SHEET A2 FOR OUTLET & DEVICE MOUNTING HEIGHTS. 1 F2 F2 8'-6" F5 F1 F1 F1 REFER TO SHEET A1.2 FOR ALL SYMBOLS AND SCHEDULES. 3 2 A10 F5 aD KEYNOTES bD cD BOARDROOM 801 F1 F8A 8'-6" F2 OPEN CEILING F1 G. ELECTRICAL DEVICES SHALL BE IVORY AND COVER PLATES SHALL BE STAINLESS STEEL. SEE ENGINEERING DRAWINGS FOR COLORS OF SPECIALTY DEVICES. OFFICE 810 1 2 A10 3 A10 1. EXPOSED STRUCTURE, MECHANICAL DUCTS AND SPRINKLER PIPES SHALL RECEIVE PAINT P-1, FLAT FINISH. SEE FINISH LEGEND ON SHEET A1.2. GC TO PROVIDE APPROPRIATE COATING FOR EACH CEILING ELEMENT INCLUDING, BUT NOT LIMITED TO DUCTWORK, PIPING, STEEL, AND CONCRETE. 1 F4 F4 F4 OFFICE 809 F4 1 3 A10 8'-6" b b F9 F9 8'-6" F1 F1 F6 CORRIDOR 818 BREAKOUT AREA 815 COPY AREA 816 c F5 b b F9 F9 F12 F3 F3 F3 F3 F3 3 A10 b b F9 F3 F1 F1 2 OPEN OFFICE 817 F9 F10 F9 1 F9 OPEN CEILING F4 F4 F4 F4 9'-0" F9 b b F9 OFFICE 808 F9 F9 F1 F1 F1 F1 F1 F1 F1 8'-6" NO. c F5 b F9 a b E ISSUED FOR BID AND PERMIT DATE REVISION F9 F11 3 AXX 03/13/15 F1 F1 F1 F1 F1 4 A10 F1 4 A10 1 E E 10'-0" E F1 E E E E E 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 E 1 8TH FLOOR REFLECTED CEILING PLAN A B 802 OFFICE 803 OFFICE C 804 OFFICE 805 OFFICE D 806 OFFICE E 807 OFFICE F PROJECT NUMBER: NORTH SHEET NO: 0213 DRAWING SCALE: 1/4" = 1'-0" 0 1' 2' 4' 8' A5 C2 B1 SERVER/ STORAGE 813 CAFE 814 OFFICE 812 5 GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM 4 E E E E RECEPTION 800 GENERAL NOTES 10'-6" CLOSET 800.1 E A. THIS DRAWING INDICATES THE LOCATION OF FIXTURES, DEVICES, AND EQUIPMENT. REFER TO ENGINEERING DRAWINGS FOR CIRCUIT DESIGN, SPECIFICATIONS AND SCHEDULES. B. DIMENSIONS INDICATED SHALL BE TO THE CENTERLINE OF ELECTRICAL OUTLET OR GROUP OF OUTLETS. SEE LEGEND SHEET A2 FOR OUTLET & DEVICE MOUNTING HEIGHTS. 13'-1" 1'-7" 4'-1" CORRIDOR 811 3 C. SYMBOL DENOTES AN EQUIPMENT TYPE. REFER TO LEGEND SHEET A1.2 AND ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION. 1'-6" 3'-6" 40" GFI 10'-5" 40" GFI D. THE G.C. SHALL NOTIFY THE ARCHITECT WHEN LAYOUT OF ELECTRICAL AND COMMUNICATION DEVICES BACKBOX LOCATIONS ARE INSTALLED. E. ELECTRICAL DEVICES SHALL BE GREY AND COVER PLATES SHALL BE BRUSHED STAINLESS STEEL, UNLESS NOTED OTHERWISE. SEE ENGINEERING DRAWINGS FOR COLORS OF SPECIALTY DEVICES. 5 OFFICE 810 40" KEYNOTES 1. WALL-MOUNTED POWER AND DATA FEED TO FURNITURE PANELS. 3 40" 30" 2. PROVIDE POWER AND DATA CONNECTION TO FURNITURE PANELS FOR EQUIPMENT IN COPY AREA. 72" 4 72" BOARDROOM 801 FEC 3. PROVIDE FLUSH FLOOR CORE DEVICE WITH DUPLEX AND TELE-DATA RECEPTACLES. 72" OFFICE 809 4. PROVIDE BLOCKING FOR WALL MOUNTED TV. PROVIDE CONNECTIVITY FROM TV TO TABLE. COORDINATE WITH FURNITURE VENDOR AND AV CONSULTANT. 40" 5. REFER TO ENGINEERING DRAWINGS FOR SCOPE. 40" 40" CORRIDOR 818 40" BREAKOUT AREA 815 4'-10" COPY AREA 816 40" 2'-2" 2 10'-0" 3 1 1 2 10'-5" OPEN OFFICE 817 3 OFFICE 808 13'-1" - 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION 4'-10" 4'-0" 4'-10" 3'-9" 4'-10" 3'-9" 6'-2" NO. 3'-3" 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 1 8TH FLOOR POWER & TELE PLAN A B 802 OFFICE 803 OFFICE C 804 OFFICE 805 OFFICE D 806 OFFICE E 807 OFFICE F PROJECT NUMBER: NORTH SHEET NO: 0213 DRAWING SCALE: 1/4" = 1'-0" 0 1' 2' 4' 8' A6 C2 B1 SERVER/ STORAGE 813 CAFE 814 OFFICE 812 5 GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM 4 RECEPTION 800 CLOSET 800.1 GENERAL NOTES A. SEE LEGEND SHEET A2 FOR DESCRIPTION OF FINISH TARGETS. SEE FINISH SPECIFICATIONS AT SHEETS A12 B. ALL PARTITIONS SHALL RECEIVE PAINT P-1 AND WALL BASE B-1, UNLESS NOTED OTHERWISE. C. ALL FLOORING SHALL BE CPT-1, UNLESS NOTED OTHERWISE. VINYL BASE SHALL BE STRAIGHT TYPE AT CARPET AND COVE TYPE AT VCT. DO NOT INSTALL WALL BASE TO MILLWORK. WC 1 2 CORRIDOR 811 D. THE G.C. SHALL PREPARE WALL, FLOOR AND CEILING SURFACES AS REQUIRED AND RECOMMENDED BY MANUFACTURER TO RECEIVE NEW FINISHES AS INDICATED ON PLAN, INCLUDING FLOOR PREP. WD 1 E. ALL HORIZONTAL SOFFIT PLANES ARE TO BE PAINTED WHITE, UNLESS NOTED OTHERWISE. VERTICAL PLANES ARE TO MATCH ADJACENT WALL SURFACES, UNLESS NOTED OTHERWISE REFER TO ELEVATIONS FOR ADDITIONAL INFORMATION. 2 VT 2 VT 1 CPT 1 CPT 1 P 2 2 F. FINISH TARGETS ARE FOR GENERAL INFORMATION. FOR EXACT LOCATIONS OF FINISHES SEE ELEVATIONS, SCHEDULES AND DETAILS. OFFICE 810 B 2 G. FLOORING TRANSITIONS AT DOOR OPENINGS SHALL OCCUR AT THE DOOR CENTERLINE. SEE FINISH SPECS FOR COLOR. SEE FLOOR FINISH TRANSITION DETAILS AT SHEET A10. 3 2 FEC BOARDROOM 801 P 2 B 2 P 2 B 2 H. FIRE EXTINGUISHER, FIRE HOSE CABINETS, AND ACCESS PANELS SHALL BE PAINTED TO MATCH ADJACENT WALL COLOR IN ALKYD ENAMEL PAINT. DO NOT PAINT METAL CABINETS WITH LATEX WALL PAINT. OFFICE 809 J. FLOORING MATERIAL SHALL BE INSTALLED UNDER NEW MILLWORK. CPT 2 CPT 1 KEYNOTES WC 2 1 CORRIDOR 818 BREAKOUT AREA 815 CPT 1 WC 2 1. PROVIDE WALL GRAPHIC ARTWORK WALL COVERING , WC-3. INCLUDE HIGH RESOLUTION PHOTOGRAPHIC IMAGE AND ARTWORK LICENSING FEES. INCLUDE ONE MOCKUP FOR COORDINATING IMAGE WITH ARCHITECT AND CLIENT. REFER TO SCHEDULE ON SHEET A1.2 FOR ADDITIONAL INFORMATION. COPY AREA 816 P 2 CPT 2 CPT 2 B 2 2. CONTINUE SPECIFIED FLOOR FINISH UNDER ALL MILLWORK. 1 P 2 2 OPEN OFFICE 817 B 2 OFFICE 808 CPT 1 1 P 2 CPT 1 CPT 1 B 2 P 2 P 2 B 2 B 2 CPT 1 CPT 1 P 2 P 2 B 2 B 2 P 2 CPT 1 NO. 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION B 2 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 1 8TH FLOOR FINISH PLAN A B 802 OFFICE 803 OFFICE C 804 OFFICE 805 OFFICE D 806 OFFICE E 807 OFFICE F PROJECT NUMBER: NORTH SHEET NO: 0213 DRAWING SCALE: 1/4" = 1'-0" 0 1' 2' 4' 8' A7 C2 B1 CAFE 814 SERVER/ STORAGE 813 OFFICE 812 5 GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM 4 RECEPTION 800 CLOSET 800.1 GENERAL NOTES A. FURNITURE PLAN IS FOR INFORMATION ONLY. G.C. SHALL COORDINATE INSTALLATION OF FURNITURE WITH OWNER'S VENDOR. B. TRAVEL DISTANCE IS REPRESENTED BY DASHED LINE AND TAKEN FROM THE FURTHEST POINT IN THE ROOM TO THE EXIT DOOR. CORRIDOR 811 OFFICE 810 3 FEC BOARDROOM 801 OFFICE 809 FLAG AREA CORRIDOR 818 BREAKOUT AREA 815 COPY AREA 816 2 OPEN OFFICE 817 99 FT 76 FT OFFICE 808 NO. 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 1 8TH FLOOR FURNITURE PLAN A B 802 OFFICE 803 OFFICE C 804 OFFICE 805 OFFICE D 806 OFFICE E 807 OFFICE F PROJECT NUMBER: NORTH SHEET NO: 0213 DRAWING SCALE: 1/4" = 1'-0" 0 1' 2' 4' 8' A8 LINE OF EXISTING STRUCTURE LOGO BY OTHERS LINE OF EXISTING STRUCTURE SCHEDULED DOOR AND FRAME 1/4" CLEAR TEMPERED GLASS SIDELIGHTS LINIE OF SOFFIT SCHEDULED DOOR AND FRAME LINE OF FINISHED CEILING 12'-6" VIF 8'-6" 8'-6" SCHEDULED WALL BASE 8'-6" 1/4" CLEAR TEMPERED GLASS, GL-1 OPEN 12'-6" SCHEDULED DOOR & FRAME LINE OF FINISHED FLOOR 8 PLASTIC LAMINATE CREDENZA WITH CUSTOM SEAT CUSHION PROVIDED BY OTHERS. PL-1 COUNTER TOP AND BASE CABINETS SCHEDULED WALL BASE GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM LINE OF FINISHED FLOOR 6'-0" EQ EQ EQ 15'-6" EQ 2'-5" 2'-5" LINE OF FINISHED FLOOR EQ 8'-2" EQ 4" GENERAL NOTES EQ A. ALL VERTICAL MILLWORK PULLS WHERE INDICATED ON DRAWINGS TO BE: OVERSIZED BAR PULL EPCO, ENGINEERED PRODUCTS CO., BP192-SS, STAINLESS STEEL C-C7.65, OVERALL LENGTH 9.84. B. ALL HORIZONTAL MILLWORK PULLS WHERE INDICATED ON DRAWINGS TO BE: OVERSIZED BAR PULL EPCO, ENGINEERED PRODUCTS CO., BP096-SS, STAINLESS STEEL C-C 3.78, OVERALL LENGTH 6.14. LINE EXISTING STRUCTURE SCHEDULED DOOR AND FRAME 2 6'-0" VIF 8'-6" 3'-0" 1'-7" 1/4" TYP SCHEDULED WALL BASE LINE OF FINISHED FLOOR 2'-5" 2'-0" PLASTIC LAMINATE CREDENZA. PL-1 COUNTER TOP AND BASE CABINETS 9'-9" EQ 8 VIF EQ 1/4" CLEAR TEMPERED GLASS SIDELIGHTS 12'-6" PROVIDE BLOCKING FOR WALL MOUNTED TV. TV PROVIDED BY OWNER 12'-6" EQ EQ EQ 8'-6" C. RECEPTION AND BOARDROOM MILLWORK PULLS TO BE ROUTED FINGER PULLS AS INDICATED IN DETAILS. 3 2'-9" 3'-0" 3'-6" 1/4" 4'-6" 1/4" 4'-9" 1/4" 3'-11" 4'-6" 1/4" 4'-9" 1/4" 4'-6" 1/4" 6'-9" 39'-1" 8 3/4" 2'-1" 3/4" 10'-9" EQ EQ EQ EQ 2'-6" EQ NO. 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION 10 12 11 2'-10" 3'-6" 9 2'-2" 6 4'-5" 5'-2" 3/4" 2'-1" EQ 3/4" 3'-0" CLEAR EQ 4'-5" 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 EQ 20" CLEAR 1'-8" 3'-3" ELEVATIONS 19'-7" PROJECT NUMBER: SHEET NO: 0213 DRAWING SCALE: 3/8" = 1'-0" 0 6" 1' 3' 5' A9.1 5'-7" 3'-0" 2'-0" 1'-0" 3'-0" 8'-1" 6" 2'-6" 3 8'-7" 2'-9" 7'-6" 5 5'-7" GARNETT ARCHITECTS, LLC 3'-0" ARCHITECTURE . PLANNING . INTERIOR DESIGN 1'-1" 8'-6" 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM 3'-2" 3'-6" 4" 2'-5" 2'-3" 3'-6" GENERAL NOTES 6'-6" A. ALL VERTICAL MILLWORK PULLS WHERE INDICATED ON DRAWINGS TO BE: OVERSIZED BAR PULL EPCO, ENGINEERED PRODUCTS CO., BP192-SS, STAINLESS STEEL C-C7.65, OVERALL LENGTH 9.84. 8'-7" 5'-1" B. ALL HORIZONTAL MILLWORK PULLS WHERE INDICATED ON DRAWINGS TO BE: 6" 3'-6" OVERSIZED BAR PULL EPCO, ENGINEERED PRODUCTS CO., BP096-SS, STAINLESS STEEL C-C 3.78, OVERALL LENGTH 6.14. 4" 2'-5" 3'-2" 1'-1" 3'-0" 1 1/2" 7'-10" C. RECEPTION AND BOARDROOM MILLWORK PULLS TO BE ROUTED FINGER PULLS AS INDICATED IN DETAILS. 1 1/2" SOLID SURFACE TRANSACTION TOP, SD-2 SOLID SURFACE TRANSACTION TOP, SD-2 SOLID SURFACE TRANSACTION TOP, SD-2 PLASTIC LAMINATE, PL-X PLASTIC LAMINATE, PL-X SOLID SURFACE WORKSURFACE, SD-1 SOLID SURFACE WORKSURFACE, SD-1 FURNITURE BY OTHERS PLASTIC LAMINATE, PL-1 PLASTIC LAMINATE, PL-1 PLASTIC LAMINATE, PL-X SOLID SURFACE WORKSURFACE, SD-1 FURNITURE BY OTHERS 2'-0" 3'-2" 3'-6" 1'-0" 4" OPEN 6" X 3'-0" RIGHT ELEV. @ RECEPTION DESK SCALE: 3/8"=1'-0" NO. 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 ELEVATIONS PROJECT NUMBER: SHEET NO: 0213 DRAWING SCALE: 3/8" = 1'-0" 0 6" 1' 3' 5' A9.2 1 5/8" SLOTTED DEFLECTION TRACK WITH SLIP JOINT FOR MOVEMENT OF STRUCTURE FIRESTOP SEALANT PARTITION TYPE "A1" CONTINUE DRYWALL UP TO DECK AT OPEN CEILING 2-1/2" SLOTTED DEFLECTION TRACK WITH SLIP JOINT FOR MOVEMENT OF STRUCTURE 2 1/2" SLOTTED DEFLECTION TRACK WITH SLIP JOINT FOR MOVEMENT OF STRUCTURE 6" 6" 6" TYPE "A1" REFER TO MECHANICAL DRAWINGS FOR RETURN AIR GRILL SIZE AND LOCATION PARTITION TYPE "D1" CONTINUE DRYWALL AND FRAMING UP TO UNDERSIDE OF DECK IN AREAS WITH OPEN CEILING PARTITION TYPE "C1" CONTINUE DRYWALL AND FRAMING UP TO UNDERSIDE OF DECK IN AREAS WITH OPEN CEILING SOUND BATT TO 24" EA. SIDE OF WALL (ONLY AS KEYNOTED ON PLAN) TYPE "A1" REFER TO REFLECTED CEILING PLAN FOR LOCATIONS WITH OPEN CEILING SCHEDULED CEILING SUSPENDED ACOUSTICAL TILE CEILING SCHEDULED CEILING SCHEDULED TRIM 2-1/2" SOUND ATTENUATION BLANKET 2-1/2" SOUND ATTENUATION BLANKET SPECIFIED WALL BASE SPECIFIED WALL BASE 2-1/2" METAL RUNNER 2 1/2" METAL RUNNER EXISTING FLOOR SLAB EXISTING FLOOR SLAB A1 2 1/2" STUD TENANT PARTITION A SCALE: 3"=1'-0" 3 3/4" 3"=1'-0" EXISTING CONCRETE COLUMN OF PARTITION GARNETT ARCHITECTS, LLC ONE LAYER 5/8" GYPSUM BOARD 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM SPECIFIED WALL BASE SCHEDULED WALL BASE 1 5/8" METAL RUNNER EXISTING FLOOR SLAB EXISTING FLOOR SLAB FRAMING SCHEDULE D1 PARTITION TYPE 'E' D SCALE: 3"=1'-0" 2 1/4" 2 1/2" STUD DEMISING SCALE: 5/8" GYPSUM BOARD C1 FURRING PARTITION C SCALE: 3"=1'-0" 3 3/4" B 1 5/8" METAL STUDS SEE FRAMING SCHEDULE FOR SPACING AND GAUGE ARCHITECTURE . PLANNING . INTERIOR DESIGN 2 1/2" METAL STUDS, SEE FRAMING SCHEDULE FOR SPACING AND GAUGE ONE LAYER 5/8" GYPSUM BOARD EACH SIDE 7/8" METAL FURRING CHANNEL 2-1/2" SOUND ATTENUATION BLANKET (AT PLUMBING LOCATIONS ONLY ONE LAYER 5/8" GYPSUM BOARD EACH SIDE 8'-6" SEE RCP 2-1/2" METAL STUDS, SEE FRAMING SCHEDULE FOR SPACING AND GAUGE SCHEDULED CEILING 1 1/2" Stud Depth Gauge 25 20 STRUCTURE ABOVE 2 1/2" SLOTTED DEFLECTION TRACK WITH SLIP JOINT FOR MOVEMENT OF STRUCTURE ACOUSTICAL SEALANT 25 EXISTING BUILDING SLAB OR DECK 2 1/2" METAL TRACK ATTACHED TO STRUCTURE 2 1/2" METAL FRAMING ADDITIONAL LAYER OF DRYWALL ON BOARDROOM SIDE 6" 2 1/2" SOUND ATTENUATION BLANKET 8'-0" U.N.O. ONE LAYER 5/8" GYPSUM BOARD EACH SIDE EXISTING STRUCTURAL DECK 20 5/8" GYPSUM BOARD OVER 2-1/2" METAL STUDS SCHEDULED CEILING 25 6" 1-1/2" ALUMINUM FRAME BY WILSON PARTITIONS OR EQUAL 20 8'-6" 8'-6" SPECIFIED WALL BASE 3 3/4" FINISHED FLOORING 2 1/2" METAL RUNNER ALIGN 1 1/2" METAL CORNER BEAD NO. 103, TYPICAL SEE PLAN SCALE: SCHEDULED CEILING AND TRIM 3"=1'-0" 8'-4" 24 7'-11" 12 9'-11" 16 9'-2" 24 8'-3" 12 11'-11" 16 11'-3" 24 10'-7" 12 13'-2" 16 12'-1" 24 10'-9" 12 15'-4" 16 14'-4" 24 13'-5" 12 17'-1" 16 15'-8" 24 14'-0" 12 22'-1" 16 19'-9" 24 16'-9" 12 25'-6" 16 23'-2" 24 20-3" 6" 5/8" GYPSUM BOARD 4 3/8" E 25 SEE PLAN SPECIFIED FINISHED FLOOR BOARD ROOM DEMISING WALL 16 METAL CORNER BEAD FIRE-RESISTANT TREATED WOOD BLOCKING M1 OFFICE STOREFRONT M SCALE: 3"=1'-0" 8'-10" 3-5/8" 1/4" CLEAR TEMPERED GLASS 2 1/2" METAL STUDS, SEE FRAMING SCHEDULE FOR SPACING AND GAUGE 12 2-1/2" ONE LAYER 5/8" GYPSUM BOARD EACH SIDE TO 6" BELOW STRUCTURE FOR AIR RETURN 1 1/2" 2-1/2" SOUND ATTENUATION BLANKET Maximum Height 1-5/8" PARTITION TYPE "M1" CONTINUE DRYWALL AND FRAMING UP TO UNDERSIDE OF DECK IN AREAS WITH OPEN CEILING ACOUSTIC SEALANT Spacing (Inches) 20 SCHEDULED PARTITION 1 SECTION @ DRYWALL SOFFIT SCALE: 3"=1'-0" 2 CEILING TRANSITION SCALE: 3"=1'-0" 10'-0" V.I.F. DRYWALL SOFFIT SCHEDULED CARPET LATEX 14" PER FOOT MAX. NOTE: TOP OF CARPET TO BE 1 4" ABOVE DIVIDER STRIP. ALIGN 5/8" GYPSUM BOARD OVER 2-1/2" METAL STUDS DOOR, WHERE SPECIFIED 1 SCHEDULED CARPET FLOORING 8" ZINC DIVIDER STRIP - EXISTING FLOOR SLAB NO. UNDERCUT AS REQ'D PAINTED STRUCTURE ABOVE (NOT SHOWN) 8'-6" ISSUED FOR BID AND PERMIT DATE REVISION SCHEDULED WOOD FLOOR 6" 4" NOM. SCHLUTER RENO-U ALUMINUM TRANSITION STRIP 03/13/15 8'-6" SCHEDULED RESILIENT FLOORING 3-3/4" 4" NOMINAL SPECIALTY CEILING SUSPENSION TRIM. PROVIDE PREFABRICATED CORNERS. 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 ALIGN SCHEDULED CEILING AND TRIM SCHEDULED CEILING PARTITION TYPES & DETAILS CENTERLINE OF SCHEDULED DOOR AND SCHLUTER STRIP METAL CORNER BEAD EXISTING EXTERIOR WINDOW 3 CEILING EDGE @ OPEN OFFICE SCALE: 3"=1'-0" 4 WINDOW TRANSITION SCALE: 3"=1'-0" PROJECT NUMBER: 5 CARPET / VCT TRANSITION SCALE: 3"=1'-0" 6 CARPET TO WOOD TRANSITION DRAWING SCALE: SCALE: AS NOTED 3"=1'-0" 0213 SHEET NO: A10 6" 1'-3" 1 1/2" WHITE 3/4" MELAMINE SHELF 3/4" SEE PLAN 3/4" POPLAR CLEATS. GC TO PROVIDE IN-WALL BLOCKING TO SUPPORT CABINETS. 2'-1" OPENING CHROMED STEEL COAT ROD W/ THREADED END SUPPORTS FIRE EXTINGUISHER AND CABINET POTTER ROEMER #1702 OR AS SPECIFIED ON FIRE PROTECTION DRAWINGS 4'-0" A.F.F. @ ACCESSIBLE 1 1/2" X 1 1/2" CONTINUOUS ANGLE SUPPORT AT WALLS. PAINT TO MATCH PARTITION. 3/4" THICK MELAMINE TRAPEZE WITH HOLE TO SUPPORT LOWER COAT ROD FOR HANDICAP ACCESSIBILITY (1)-30" SECTION 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM SPECIFIED WC-3, TRIM TIGHT TO EDGE PROFILE FRY REGLET PROTRUDING EDGE PROFILE DRMPET-100, CLEAR ANODIZED ALUMINUM 1'-9" SPECIFIED PULLS FIRE EXTINGUISHER CABINET DETAIL SCALE: 3 3"=1'-0" BOARDROOM WALLCOVERING DETAIL SCALE: 3"=1'-0" 2'-0" SPECIFIED PARTITION 14" SOLID SURFACE COUNTERTOP 1 1/2" POPLAR CLEATS. MILLWORKER TO PROVIDE WALL BLOCKING TO SUPPORT CABINETS. 1 1/2" PLASTIC LAMINATE TOP W/ 3/4" PLAS. LAM. RETURN AT ENDS WHITE MELAMINE INTEROR PLAM DOOR WITH ROUTED FINGER PULL AND CUSHIONED SELF CLOSING HINGES 1 1/2" EQUAL WHITE MELAMINE INTERIOR WITH ADJUSTBLE SHELF FIXED PLASTIC LAMINATE SHELVES PLASTIC LAMINATE MICROWAVE OVEN SHELF WHITE MELAMINE INTERIOR 3/4" 1'-1" SCHEDULED EQUIPMENT 1 1/2" 3'-6" WHITE MELAMINE INTERIOR WITH ADJUSTABLE SHELF 3/4" 2'-5" EQUAL 2'-0" FINISHED FLOOR 2'-11" SCHEDULED UNDERCABINET LIGHT FIXTURE BY GC 2'-1" 2'-1" PLASTIC LAMINATE UPPER CABINET BAR PULL EPCO, ENGINEERED PRODUCTS CO., BP2565-SN, SATIN NICKEL, C-C 10.08", OVERALL LENGTH 13.23" 1'-2" 2 3"=1'-0" SEE ELEVATION ARCHITECTURE . PLANNING . INTERIOR DESIGN 7'-9" SECTION @ COAT ROD & HAT SHELF SCALE: GARNETT ARCHITECTS, LLC PLASTIC LAMINATE UPPER CABINET SINGLE LAYER OF DRYWALL AT RECESSED ART NICHE FURRING WALL 5/8" GYPSUM BOARD OVER 2 1/2" METAL STUD CONSTRUCTION 2'-6" A.F.F. INTERMEDIATE SUPPORTS TO BE "STANLEY" NO. 7045 SHELF AND CLOSET POLE BRACKET. PAINT TO MATCH PARTITION. BRACKETS TO BE 4'-0" MAX. O.C. WHITE MELAMINE INTERIOR WITH ADJUSTABLE SHELF 1'-8" 5'-9" A.F.F. TYP. 1 DRYWALL SOFFIT ADJUSTABLE PLAM SHELVES PLASTIC LAMINATE TOE KICK 1'-1" 1-1/2" = 1'-0" CAFE COUNTERTOP WITH OPEN SHELVING SCALE: 1 1/2"=1'-0" SPECIFIED FULL HEIGHT BACKSPLASH 2'-1" 7 TYPICAL BASE CABINET SCALE: 8 1-1/2" = 1'-0" SCALE: SPECIFIED FULL HEIGHT BACKSPLASH SPECIFIED FULL HEIGHT BACKSPLASH SOLID SURFACE COUNTERTOP SOLID SURFACE COUNTERTOP SOLID SURFACE COUNTERTOP 2'-1" 2'-1" SOLID SURFACE COUNTERTOP 3/4" 6" 3/4" 6" PLASTIC LAMINATE CABINET DOOR W/ QUIRK TO MATCH DRAWER FRONT. PROVIDE SELF-CLOSING HINGES. PLAM DRAWER WITH HEAVY-DUTYDRAWER GLIDES, TYPICAL 1 1/2" HEAVY-DUTYDRAWER GLIDES 1 1/2" SCHEDULED UNDER-MOUNT STAINLESS STEEL SINK, STRAINER DRAIN AND ACCESSIBLE FAUCET 1 1/2"=1'-0" SPECIFIED FULL HEIGHT BACKSPLASH 2'-1" 1 1/2" SECTION @ MICROWAVE TOWER SPECIFIED PULLS SPECIFIED PULLS, TYPICAL SPECIFIED PULLS, TYPICAL PLAM QUARK TO MATCH DRAWER FRONT PLAM CABINET DOOR W/ SELF-CLOSING HINGES AND CUSHION SILENCERS PLAM TOE KICK 4" 4" PLAM TOE KICK 03/03/15 ISSUED FOR ENGINEERING DATE REVISION 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 PLAM TOE KICK MILLWORK DETAILS 4" 3/4" PLASTIC LAMINATE INTERGRAL TOE KICK SCREWED TO 18 GAUGE BRAKE-FORMED STEEL SHEET. BEVEL SWINGING EDGE FOR CLEARANCE. 1 NO. PULL OUT TRASH/ RECYCLE BIN. HAFELE US CARGO 21 502.74.852 WITH (2) 10.57 GALLON TRASH BINS 502.74.900 2'-10" 3/4" WHITE MELAMINE INTERIOR 2'-10" 2'-0" WHITE MELAMINE INTERIOR WITH ADJUSTABLE SHELF 4" SCHEDULED WALL BASE SEE ELEVATION 2'-10" SPECIFIED PULL SCHEDULED PARTITION PLAM DRAWER WITH HEAVY-DUTY DRAWER GLIDES 3/4" SCALE: 6 1 1/2" SECTION @ UPPER CABINET 6" 5 4" 4" 1 1/2" PLAM TOE KICK PROJECT NUMBER: 9 ACCESSIBLE SINK CABINET SCALE: 1 1/2"=1'-0" 10 TYPICAL BASE CABINET SCALE: 1-1/2" = 1'-0" 11 TYPICAL BASE CABINET SCALE: 1-1/2" = 1'-0" 12 TYPICAL BASE CABINET W/ TRASH DRAWING SCALE: SCALE: AS NOTED 1-1/2" = 1'-0" 0213 SHEET NO: A11 A1 = 2'-8" 3'-0" 1 1/2" EQUAL EQUAL 1 1/2" 1 1/2" 1 1/2" 6'-0" EQ. 1 1/2" 1 1/2" ALUMINUM FRAME 7 A12 ALUMINUM VERTICAL MULLION. REFER TO PLAN FOR LOCATION WOOD VENEER SOLID CORE DOOR (WD-2) 1/4" TEMPERED CLEAR GLASS (GL-1) 5 A12 4'-0" ALUMINUM FRAME CONCEALED FRAME 8 A12 WOOD VENEER RAIL AND STILE DOOR (WD-2) WITH 41" GLASS PANEL 1/4" TEMPERED CLEAR GLASS (GL-1) 6 A12 5 A12 SOLID CORE WOOD DOOR, PAINTED 8 A12 WOOD VENEER RAIL AND STILE DOOR (WD-2) WITH 41" GLASS PANEL GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM 1/4" TEMPERED CLEAR GLASS (GL-1) 3'-4" 8 A12 3'-4" 6 A12 5 A12 6 A12 DOOR HARDWARE 5 A12 REFER TO SHEET A1.2 FOR DOOR HARDWARE SCHEDULE B DOOR W/ SIDELITE SCALE: C 3/8"=1'-0" SCALE: D 3/8"=1'-0" ENTRY DOOR PAIR SCALE: PIVOT DOOR PAIR E 3/8"=1'-0" SCALE: SEE PLAN 1 1/2" 3/8"=1'-0" SEE PLAN 1 1/2" SEE PLAN 1 1/2" SEE PLAN DOOR W/ SIDELITE 1/2" 1 1/2" 3'-4" 1 1/2" ALUMINUM VERTICAL MULLION 8'-0" A3 = 8'-6" 8'-0" 7 A12 5 A12 A1A2 A3 TYPICAL DOOR A SCALE: 3/8"=1'-0" EQ. SEE PLAN ALUMINUM FRAME TYPE "A2" 20 MINUTE RATED WOOD VENEER SOLID CORE DOOR (WD-2 1 1/2" 3 A12 SEE PLAN ALUMINUM FRAME COAT HOOK OFFICE SIDE ONLY WOOD VENEER SOLID CORE DOOR (WD-2) 1 1/2" 8'-6" 1 1/2" A3: SOLID CORE WOOD DOOR PAINTED 7 A12 1 1/2" 2 A12 8'-0" 1 1/2" 3'-0" 1 A12 1 1/2" 1 1/2" 1 1/2" 3'-4" 3'-0" 2 A12 1 A12 2 A12 8'-6" 1 1/2" 1 A12 1 1/2" 1 A12 POPLAR HEADER (PAINT TO MATCH SOFFIT) CLEAR ANODIZED ALUMINUM FRAME CLEAR ANODIZED ALUMINUM FRAME SCHEDULED DOOR SCHEDULED DOOR 1 HEAD @ ALUM. DOOR FRAME SCALE: 3"=1'-0" 2 HEAD @ SIDELIGHT ALUM. FRAME SCALE: 3"=1'-0" 3 CENTER PIVOT HINGE CLEAR ANODIZED ALUMINUM FRAME SCHEDULED DOOR SCHEDULED DOOR HEAD @ CLOSET DOOR SCALE: 4 3"=1'-0" 1 1/2" HEAD @ ALUM. DOOR FRAME SCALE: 3"=1'-0" 1 1/2" 1/4" TEMPERED GLASS ALUMINUM FRAME NO. SCHEDULED DOOR SCHEDULED FLOORING SCHEDULED FLOORING EXISITNG SLAB 1 1/2" 1 1/2" 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION 1 1/2" 4" 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 1 1/2" UNDERCUT AS REQ'D EXISTING CONCRETE SLAB DOOR TYPES & DETAILS CARPET TRANSITION UNDER CENTERLINE OF CLOSED DOOR PROJECT NUMBER: 5 THRESHOLD @ DOOR SCALE: 3"=1'-0" 6 SILL @ SIDELIGHT SCALE: 3"=1'-0" 7 JAMB @ DOOR SCALE: 3"=1'-0" 8 JAMB @ SIDELIGHT SCALE: 3"=1'-0" SHEET NO: 0213 DRAWING SCALE: 3/8" = 1'-0" 0 6" 1' 3' 5' A12 ARCHITECT'S SPECIFICATIONS SECTION 01631 - SUBSTITUTIONS SECTION 06402 - INTERIOR ARCHITECTURAL WOODWORK SECTION 09255 - GYPSUM BOARD ASSEMBLIES (continued) A. Substitutions: Changes in products, materials, equipment, and methods of construction required by the Contract Documents proposed by the Contractor after award of the Contract are considered to be requests for substitutions. 1.0 SUBMITTALS 1.1 STEEL FRAMING FOR WALLS AND PARTITIONS A. Shop drawings showing location of each item, dimensioned plans and elevations, large-scale details, attachment devices, and other components. A. General: Provide steel framing members complying with the following requirements: SECTION 01010 - SUMMARY OF WORK 1.0 SUBMITTALS 1. Protective Coating: ASTM A 653, G 40 hot-dip galvanized coating. A. The Project consists of interior alteration to: 1. Project Location: 10 North Dearborn Street, 8th Floor, Chicago, Illinois, 60602. A. Substitution Request Submittal: The Architect or Owner will consider requests for substitution if received within 15 days after commencement of the Work. Requests received more than 15 days after commencement of the Work may be considered or rejected at the discretion of the Architect. 2. Owner (Tenant): Civic Federation SECTION 01026 - UNIT PRICES A. Unit price is an amount proposed by bidders, stated on the Bid Form, as a price per unit of measurement for materials or services added to or deducted from the Contract Sum by appropriate modification, if the estimated quantities of Work required by the Contract Documents are increased or decreased. SECTION 01027 - APPLICATIONS FOR PAYMENT 1. Submit 3 copies of each request for substitution for consideration. Submit requests in the form and according to procedures required for change-order proposals. 2. Identify the product or the fabrication or installation method to be replaced in each request. Include related Specification Section and Drawing numbers. 3. Provide complete documentation showing compliance with the requirements for substitutions. 4. Architect's Action: If necessary, the Architect will request additional information or documentation for evaluation within one week of receipt of a request for substitution. The Architect will notify the Contractor of acceptance or rejection of the substitution within 2 weeks of receipt of the request, or one week of receipt of additional information or documentation, whichever is later. Acceptance will be in the form of a change order. A. Payment-Application Forms: Use AIA Document G702 and Continuation Sheets G703 as the form for Applications for Payment. SECTION 01740 - WARRANTIES SECTION 01030 - ALTERNATES (SEE BID FORM FOR ALTERNATES) 1.0 WARRANTY REQUIREMENTS A. Definition: An alternate is an amount proposed by bidders and stated on the Bid Form for certain work defined in the Bidding Requirements that may be added to or deducted from the Base Bid amount if the Owner decides to accept a corresponding change in either the amount of construction to be completed, or in the products, materials, equipment, systems, or installation methods described in the Contract Documents. A. Related Damages and Losses: When correcting failed or damaged warranted construction, remove and replace construction that has been damaged as a result of such failure or must be removed and replaced to provide access for correction of warranted construction. 1. The cost or credit for each alternate is the net addition to or deduction from the Contract Sum to incorporate the Alternate into the Work. No other adjustments are made to the Contract Sum. SECTION 01035 - MODIFICATION PROCEDURES 1.0 MINOR CHANGES IN THE WORK A. The Architect will issue supplemental instructions authorizing minor changes in the Work, not involving adjustment to the Contract Sum or Contract Time, on AIA Form G710, Architect's Supplemental Instructions. 1.1 CHANGE ORDER PROPOSAL REQUESTS A. Owner-Initiated Proposal Requests: The Architect will issue a detailed description of proposed changes in the Work that will require adjustment to the Contract Sum or Contract Time. If necessary, the description will include supplemental or revised Drawings and Specifications. 1. Proposal requests issued by the Architect are for information only. Do not consider them as an instruction either to stop work in progress or to execute the proposed change. 2. Within 20 days of receipt of a proposal request, submit an estimate of cost necessary to execute the change to the Architect for the Owner's review. a. Include a list of quantities of products required and unit costs, with the total amount of purchases to be made. Where requested, furnish survey data to substantiate quantities. b. Indicate applicable taxes, delivery charges, equipment rental, and amounts of trade discounts. c. Include a statement indicating the effect the proposed change in the Work will have on the Contract Time. B. Contractor-Initiated Proposals: When latent or unforseen conditions require modifications to the Contract, the Contractor may propose changes by submitting a request for a change to the Architect. 1. Include a statement outlining the reasons for the change and the effect of the change on the Work. Provide a complete description of the proposed change. Indicate the effect of the proposed change on the Contract Sum and Contract Time. 2. Include a list of quantities of products required and unit costs, with the total amount of purchases to be made. Where requested, furnish survey data to substantiate quantities. 3. Indicate applicable taxes, delivery charges, equipment rental, and amounts of trade discounts. 4. Comply with requirements in Section "Product Substitutions" if the proposed change requires substitution of one product or system for a product or system specified. C. Proposal Request Form: Use AIA Document G709 for Change Order Proposal Requests. 1.2 CONSTRUCTION CHANGE DIRECTIVE A. Construction Change Directive: When the Owner and the Contractor disagree on the terms of a Proposal Request, the Architect may issue a Construction Change Directive on AIA Form G714. The Construction Change Directive instructs the Contractor to proceed with a change in the Work, for subsequent inclusion in a Change Order. B. Reinstatement of Warranty: When Work covered by a warranty has failed and been corrected by replacement or rebuilding, reinstate the warranty by written endorsement. The reinstated warranty shall be equal to the original warranty with an equitable adjustment for depreciation. C. Replacement Cost: Upon determination that Work covered by a warranty has failed, replace or rebuild the Work to an acceptable condition complying with requirements of the Contract Documents. The Contractor is responsible for the cost of replacing or rebuilding defective Work regardless of whether the Owner has benefited from use of the Work through a portion of its anticipated useful service life. D. Owner's Recourse: Expressed warranties made to the Owner are in addition to implied warranties and shall not limit the duties, obligations, rights, and remedies otherwise available under the law. Expressed warranty periods shall not be interpreted as limitations on the time in which the Owner can enforce such other duties, obligations, rights, or remedies. 1. Rejection of Warranties: The Owner reserves the right to reject warranties and to limit selection to products with warranties not in conflict with requirements of the Contract Documents. 1. Show details full size. 2. Show locations and sizes of furring, blocking, and hanging strips, including concealed blocking and reinforcing specified in other Sections. 3. Show locations and sizes of cutouts and holes for plumbing fixtures, faucets, soap dispensers, and other items installed in architectural woodwork. 4. Show veneer leaves with dimensions, grain direction, exposed face, and an identification number indicated for each leaf. Identification number shall indicate the flitch and the sequence within the flitch for each leaf. 5. Apply WIC Certified Compliance Label to first page of shop drawings. B. Documentation: Maintain detailed records on a time and material basis of work required by the Construction Change Directive. SECTION 01300 - SUBMITTALS 1.0 SUBMITTAL PROCEDURES A. Coordination: Coordinate preparation and processing of submittals with performance of construction activities. Transmit each submittal sufficiently in advance of performance of related construction activities to avoid delay. 1. Coordinate each submittal with fabrication, purchasing, testing, delivery, other submittals, and related activities that require sequential activity. 1. Lumber with or for transparent finish, 24 by 24 inches, for each species and cut, finished on one side and one edge. 2. Veneer leaves representative of and selected from flitches to be used for transparent-finished woodwork. 3. Wood-veneer-faced panel products, with or for transparent finish, 8 by 10 inches , for each species and cut. Include at least one face-veneer seam and finish one-half of face as specified. a. Step finish materials on sample to show and clearly define each coat. 4. Solid surfacing materials, 6 inches square. 5. Exposed cabinet hardware, one unit for each type and finish. SECTION 08110 - STEEL DOORS AND FRAMES (NOT USED) 1.0 SUBMITTALS a. The Architect reserves the right to withhold action on a submittal requiring coordination with other submittals until all related submittals are received. B. Shop Drawings showing fabrication and installation of steel doors and frames. Include details of each frame type, elevations of door design types, conditions at openings, details of construction, location and installation requirements of door and frame hardware and reinforcements, and details of joints and connections. Show anchorage and accessory items. C. Door Schedule: Submit schedule of doors and frames using same reference numbers for details and openings as those on Contract Drawings. 1. Indicate coordination of glazing frames and stops with glass and glazing requirements. a. Allow 2 weeks for initial review. Allow additional time if the Architect must delay processing to permit coordination with subsequent submittals. b. If an intermediate submittal is necessary, process the same as the initial submittal. c. Allow 1 week for reprocessing each submittal. d. No extension of Contract Time will be authorized because of failure to transmit submittals to the Architect sufficiently in advance of the Work to permit processing. B. Submittal Preparation: Place a permanent label or title block on each submittal for identification. Indicate the name of the entity that prepared each submittal on the label or title block. 1.0 DEFINITIONS SECTION 08211 - FLUSH WOOD DOORS A. Remove: Remove and legally dispose of items except those indicated to be reinstalled, salvaged, or to remain the Owner's property. 1.0 SUBMITTALS 1. Provide a space approximately 4 by 5 inches on the label or beside the title block on Shop Drawings to record the Contractor's review and approval markings and the action taken. 2. Include the following information on the label for processing and recording action taken. a. Project name. b. Date. c. Name and address of the Contractor. d. Name and address of the subcontractor. e. Name and address of the supplier. f. Name of the manufacturer. g. Drawing number and detail references, as appropriate. C. Submittal Transmittal: Package each submittal appropriately for transmittal and handling. Transmit each submittal from the Contractor to the Architect using a transmittal form. The Architect will not accept submittals received from sources other than the Contractor. 1. On the transmittal, record relevant information and requests for data. On the form, or separate sheet, record deviations from Contract Document requirements, including variations and limitations. Include Contractor's certification that information complies with Contract Document requirements. 2. Transmittal Form: Use AIA Document G810. 1.1 SHOP DRAWINGS A. Submit newly prepared information drawn accurately to scale. Highlight, encircle, or otherwise indicate deviations from the Contract Documents. Do not reproduce Contract Documents or copy standard information as the basis of Shop Drawings. Standard information prepared without specific reference to the Project is not a Shop Drawing. B. Shop Drawings include fabrication and installation Drawings, setting diagrams, schedules, patterns, templates and similar Drawings. Include the following information: 1. Dimensions. 2. Identification of products and materials included by sheet and detail number. 3. Compliance with specified standards. 4. Notation of coordination requirements. 5. Notation of dimensions established by field measurement. 6. Sheet Size: Except for templates, patterns and similar full-size Drawings, submit Shop Drawings on sheets at least 8-1/2 by 11 inches but no larger than 36 by 48 inches. 7. Initial Submittal: Submit one correctable, translucent, reproducible print and one blue- or black-line print for the Architect's or Owner's review. The Architect or Owner will return the reproducible print. 8. Final Submittal: Submit 3 blue- or black-line prints and 2 additional prints where required for maintenance manuals, plus the number of prints needed by the Architect or Owner for distribution. The Architect will retain 2 prints and return the remainder. GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN 1. Offset Configuration: Shadow-line design with offset projecting out from depth of stud. 2. Available Product: Subject to compliance with requirements, a product that may be incorporated in the Work includes, but is not limited to, "Fire Trak" manufactured by Fire Trak Corp. 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM E. Steel Rigid Furring Channels: ASTM C 645, hat shaped, depth and minimum thickness of base (uncoated) metal as follows: Thickness: 0.0179 inch, unless otherwise indicated. F. Furring Brackets: Serrated-arm type, adjustable, fabricated from corrosion-resistant steel sheet complying with ASTM C 645, minimum thickness of base (uncoated) metal of 0.0329 inch, designed for screw attachment to steel studs and steel rigid furring channels used for furring. 1. Single-Leg Configuration: Asymmetric-shaped channel with face connected to a single flange by a single-slotted leg (web). 2. Double-Leg Configuration: Hat-shaped channel with 1-1/2-inch wide face connected to flanges by double-slotted or expanded-metal legs (webs). 3. Single- or Double-Leg Configuration: Asymmetric-shaped channel with face connected to a single flange by a single-slotted leg (web) or hat-shaped channel, with 1-1/2-inch wide face connected to flanges by double-slotted or expanded-metal legs (webs).DS G. Steel Flat Strap and Backing Plate: Steel sheet for blocking and bracing complying with ASTM A 653 or ASTM A 568, length and width as indicated, and with a minimum base metal (uncoated) thickness as follows: 1. Thickness: 0.0329 inch, 20 gauge where indicated. A. Product Data: For each type of door. Include details of core and edge construction, trim for openings, and louvers. B. Remove and Salvage: Items indicated to be removed and salvaged remain the Owner's property. Remove, clean, and pack or crate items to protect against damage. Identify contents of containers and deliver to Owner's designated storage area. C. Remove and Reinstall: Remove items indicated; clean, service, and otherwise prepare them for reuse; store and protect against damage. Reinstall items in the same locations or in locations indicated. D. Existing to Remain: Protect construction indicated to remain against damage and soiling during selective demolition. When permitted by the Architect, items may be removed to a suitable, protected storage location during selective demolition and then cleaned and reinstalled in their original locations. 1. Include factory-finishing specifications. B. Shop Drawings: Indicate location, size, and hand of each door; elevation of each kind of door; construction details not covered in Product Data; location and extent of hardware blocking; and other pertinent data. 1. Indicate dimensions and locations of mortises and holes for hardware. 2. Indicate dimensions and locations of cutouts. 3. Indicate requirements for veneer matching. 4. Indicate doors to be factory finished and finish requirements. 5. Indicate fire ratings for fire doors. 1.0 SELECTIVE DEMOLITION H. Fasteners for Metal Framing: Provide fasteners of type, material, size, corrosion resistance, holding power, and other properties required to fasten steel framing and furring members securely to substrates involved; complying with the recommendations of gypsum board manufacturers for applications indicated. 1.2 GYPSUM BOARD PRODUCTS A. General: Provide gypsum board of types indicated in maximum lengths available that will minimize end-to-end butt joints in each area indicated to receive gypsum board application. 1. Widths: Provide gypsum board in widths of 48 inches. B. Gypsum Wallboard: ASTM C 36 and as follows: C. Samples for Verification: As follows: A. Demolish and remove existing construction only to the extent required by new construction and as indicated. Use methods required to complete Work within limitations of governing regulations and as follows: 1. Neatly cut openings and holes plumb, square, and true to dimensions required. Use cutting methods least likely to damage construction to remain or adjoining construction. To minimize disturbance of adjacent surfaces, use hand or small power tools designed for sawing or grinding, not hammering and chopping. Temporarily cover openings to remain. 3. Do not use cutting torches until work area is cleared of flammable materials. At concealed spaces, such as duct and pipe interiors, verify condition and contents of hidden space before starting flame-cutting operations. Maintain portable fire-suppression devices during flame-cutting operations. 5. Remove decayed, vermin-infested, or otherwise dangerous or unsuitable materials and promptly dispose of off-site. 6. Locate selective demolition equipment throughout the structure and remove debris and materials so as not to impose excessive loads on supporting walls, floors, or framing. SECTION 08700 - FINISH HARDWARE A. Furnish all finish hardware required to complete the work as indicated on the Drawings, as inferred through drawings and specifications, and as herein specified. B. Furnish all trim, attachments and fastenings specified or required for proper and complete installation. C. Furnish thresholds, perimeter seals, gaskets and door bottoms. D. Furnish All Glass Door Hardware. E. Furnish power supplies for electric hardware. A. General: Promptly dispose of demolished materials. Do not allow demolished materials to accumulate on-site. D. Exterior Gypsum Soffit Board: ASTM C 931, with manufacturer's standard edges, of type and thickness indicated below: 1. Type: Regular, unless otherwise indicated. 2. Type: Type X where required for fire-resistance-rated assemblies and where indicated. 3. Thickness: 5/8 inch, unless otherwise indicated. C. Water-Resistant Gypsum Backing Board: ASTM C 630 and as follows: 1. Type: Regular, unless otherwise indicated. 2. Thickness: 5/8 inch, unless otherwise indicated. 1.1 GENERAL REQUIREMENTS A. Proper kind and type: The hardware shall be the proper kind for its required use and shall fit its intended location perfectly. Should any hardware, as specified, fail to meet the intended requirements or require any modifications to suit the intended location, this matter, or any other necessary advance information, shall be brought to the attention of the architect for correction or advice in ample time to avoid delay in the manufacture and delivery of the hardware. 7. Dispose of demolished items and materials promptly. On-site storage or sale of removed items is prohibited. 8. Return elements of construction and surfaces to remain to condition existing before start of selective demolition operations. 1. Type: Regular for vertical surfaces, unless otherwise indicated. 2. Type: Type X where required for fire-resistance-rated assemblies. 3. Type: Sag-resistant type for ceiling surfaces. 4. Edges: Tapered. 5. Thickness: 5/8 inch, unless otherwise indicated. 6. Type: Foil backed where indicated. 1. Corner sections of doors approximately 8 by 10 inches with door faces and edgings representing the typical range of color and grain for each species of veneer and solid lumber required. Finish sample with same materials proposed for factory-finished doors. 1.0 DESCRIPTION 1. In order to insure proper placement and fit, all hardware in connection with metal door or metal frames shall be made to template. Templates or physical hardware items shall be furnished to manufacturers concerned, and shall be supplied sufficiently in advance to avoid delay in the work. 2. Warranty: All hardware shall be warranted for a period of one year from date of Substantial Completion or additionally per the provisions of warranty sections. Defects in materials and workmanship occurring during the warranty period shall be corrected to the complete satisfaction of the architect. Re-installation of defective product during the warranty period will be the responsibility of the manufacturer/representative. B. Disposal: Transport demolished materials off the Project site and legally dispose of them. 3. Electrical coordination: Before any electrically controlled and/or operated hardware is ordered, voltages must be coordinate with Electrical trade in writing. 1.3 INSTALLING TRIM ACCESSORIES A. General: For trim with back flanges intended for fasteners, attach to framing with same fasteners used for panels. Otherwise, attach trim according to manufacturer's written instructions. Generally, retain first option in paragraph below and show joints on Drawings to comply with ASTM C 840 requirements for spacing control (expansion) joints. B. Control Joints: Install control joints according to ASTM C 840 and in specific locations approved by Architect for visual effect. 1.4 FINISHING GYPSUM BOARD ASSEMBLIES A. General: Treat gypsum board joints, interior angles, edge trim, control joints, penetrations, fastener heads, surface defects, and elsewhere as required to prepare gypsum board surfaces for decoration. Promptly remove residual joint compound from adjacent surfaces. 1.0 FERROUS METALS 1.2 SUBMITTALS B. Prefill open joints, rounded or beveled edges, and damaged surface areas. A. Steel Plates, Shapes, and Bars: ASTM A 36/A 36M. A. Hardware list: C. Apply joint tape over gypsum board joints, except those with trim having flanges not intended for tape. See "Gypsum Board Finish Levels" Article in the Evaluations for a discussion of ASTM C 840 requirements. B. Slotted Channel Framing: Cold-formed metal channels with flange edges returned toward web and with 9/16-inch- wide slotted holes in webs at 2 inches o.c. 1. Width of Channels: 1-5/8 inches. 2. Depth of Channels: 1-5/8 inches. 3. Metal and Thickness: Uncoated steel complying with ASTM A 570, Grade 33; 0.0966- minimum thickness. 4. Finish: Rust-inhibitive, baked-on, acrylic enamel. C. Welding Rods and Bare Electrodes: Select according to AWS specifications for metal alloy welded. 1.0 SUBMITTAL PROCEDURES D. Deflection and Firestop Track: Top runner designed to allow partition heads to expand and contract with movement of structure above while maintaining continuity of the assembly. Comply with requirements of ASTM C 645 except configuration, of thickness indicated for studs and width to accommodate depth of studs indicated with flanges offset at midpoint to accommodate gypsum board thickness. A. Provide doors and frames complying with ANSI/SDI 100 "Recommended Specifications for Standard Steel Doors and Frames" and as specified. SECTION 02071 - SELECTIVE DEMOLITION FOR INTERIORS SECTION 05500 - METAL FABRICATIONS 3. Processing: To avoid the need to delay installation as a result of the time required to process submittals, allow sufficient time for submittal review, including time for resubmittals. C. Deflection Track: Manufacturer's top runner complying with the requirements of ASTM C 645 and with 2-inch-deep flanges. A. Product Data for each type of door and frame specified, including details of construction, materials, dimensions, hardware preparation, core, label compliance, sound ratings, profiles, and finishes. B. Fire-Rated Door Assemblies: Units that comply with NFPA 80, are identical to door and frame assemblies tested for fire-test-response characteristics per ASTM E 152, and are labeled and listed by UL, Warnock Hersey, or another testing and inspecting agency acceptable to authorities having jurisdiction. F. In no case shall the warranty for any portion of the Work be less than one year after the date of Owner's occupancy. 1.1 DISPOSAL OF DEMOLISHED MATERIALS 2. Coordinate transmittal of different types of submittals for related elements of the Work so processing will not be delayed by the need to review submittals concurrently for coordination. 1. Thickness: 0.0179 inch, unless otherwise indicated. 2. Thickness: 0.0329 inch as follows: a. For head runner, sill runner, jamb, and cripple studs at door and other openings. b. In locations to receive cementitious backer units. c. Where indicated. 3. Depth: 6 inches where indicated. 4. Depth: 3-5/8 inches where indicated. 5. Depth: 2-1/2 inches where indicated. 1.1 QUALITY ASSURANCE E. Where the Contract Documents require a special warranty, or similar commitment on the Work or part of the Work, the Owner reserves the right to refuse to accept the Work, until the Contractor presents evidence that entities required to countersign such commitments are willing to do so. 4. Maintain adequate ventilation when using cutting torches. 1. After completion of the change, submit an itemized account and supporting data necessary to substantiate cost and time adjustments to the Contract. B. Steel Studs and Runners: ASTM C 645, with flange edges of studs bent back 90 degrees and doubled over to form 3/16-inch- wide minimum lip (return), and complying with the following requirements for minimum thickness of base (uncoated) metal and for depth: B. Samples for verification of the following: 2. Cut or drill from the exposed or finished side into concealed surfaces to avoid marring existing finished surfaces. 1. The Construction Change Directive contains a complete description of the change in the Work. It also designates the method to be followed to determine change in the Contract Sum or Contract Time. 2. Protective Coating: ASTM A 653, G 40 hot-dip galvanized coating for framing members attached to and within 10 feet of exterior walls. l. Within 15 days after award of contract, prepare and submit a hardware schedule (4 copies) to the architect for review. This schedule shall be in vertical format only. Horizontal door/hardware schedules will be rejected. 2. The list shall identify each hardware item by manufacturer, including manufacturer's catalog number, cut sheets, and exact location in the work, including door details and index. 3. Hardware list shall be in suitable form to facilitate review by the architect. 4. Review of the hardware schedule by the architect does not relieve the hardware supplier from the responsibility of furnishing the job in a complete fashion. 5. The hardware supplier shall furnish to the Owner/Architect a copy of purchase orders showing the date of order placement if requested. D. Gypsum Board Finish Levels: Finish panels to levels indicated below, according to ASTM C 840, for locations indicated: 1. Level 1: Embed tape at joints in ceiling plenum areas, concealed areas, and where indicated, unless a higher level of finish is required for fire-resistance-rated assemblies and sound-rated assemblies. 2. Level 2: Embed tape and apply separate first coat of joint compound to tape, fasteners, and trim flanges where panels are substrate for tile and where indicated. 1.1 PAINT A. Shop Primers: Provide primers that comply with Division 9 Section "Painting." B. Catalog cuts: 1. Submit catalog cuts of every item furnished for this project. 2. Show all finishes, sizes, catalog numbers and pictures. Explain fully all abbreviations. B. Shop Primer for Ferrous Metal: Fast-curing, lead- and chromate-free, universal modified-alkyd primer complying with performance requirements in FS TT-P-664; selected for good resistance to normal atmospheric corrosion, compatibility with finish paint systems indicated, and capability to provide a sound foundation for field-applied topcoats despite prolonged exposure. SECTION 08800 - GLAZING A. Safety Glass: Products complying with ANSI Z97.1 and testing requirements of 16 CFR Part 1201 for Category II materials. Level 3 is suitable for surfaces receiving medium- or heavy-textured finishes before painting or heavy wallcoverings where lighting conditions are not critical. 3. Level 3: Embed tape and apply separate first and fill coats of joint compound to tape, fasteners, and trim flanges where indicated. Level 4 is suitable for surfaces receiving light-textured finish wallcoverings and flat paints. It is generally the standard exposed finish. 1.2 FASTENERS SECTION 09255 - GYPSUM BOARD ASSEMBLIES A. Bolts and Nuts: Regular hexagon-head bolts, ASTM A 307, Grade ; with hex nuts, ASTM A ; and, where indicated, flat washers. B. Expansion Anchors: Anchor bolt and sleeve assembly of material indicated below with capability to sustain, without failure, a load equal to six times the load imposed when installed in unit masonry and equal to four times the load imposed when installed in concrete, as determined by testing per ASTM E 488, conducted by a qualified independent testing agency. 1. Material: Carbon-steel components zinc-plated to comply with ASTM B 633, Class Fe/Zn 5. A. Toggle Bolts: FS FF-B-588, tumble-wing type, class and style as needed. 4. Level 4: Embed tape and apply separate first, fill, and finish coats of joint compound to tape, fasteners, and trim flanges at panel surfaces that will be exposed to view, unless otherwise indicated. 1.0 STEEL FRAMING COMPONENTS FOR SUSPENDED AND FURRED CEILINGS A. General: Provide components complying with ASTM C 754 for conditions indicated. B. Powder-Actuated Fasteners in Concrete: Fastener system of type suitable for application indicated, fabricated from corrosion-resistant materials, with clips or other accessory devices for attaching hangers of type indicated, and with capability to sustain, without failure, a load equal to 10 times that imposed by ceiling construction, as determined by testing according to ASTM E 1190 conducted by a qualified independent testing agency. Level 5 is suitable for surfaces receiving gloss and semigloss enamels and surfaces subject to severe lighting. It is considered a high-quality gypsum board finish. 5. Level 5: Embed tape and apply separate first, fill, and finish coats of joint compound to tape, fasteners, and trim flanges, and apply skim coat of joint compound over entire surface where indicated. NO. 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION E. Glass-Mat Gypsum Sheathing Board: Finish according to manufacturer's written instructions for use as exposed soffit board. C. Wire Ties: ASTM A 641, Class 1 zinc coating, soft temper, 0.062 inch thick. F. Glass-Mat, Water-Resistant Backing Panels: Finish according to manufacturer's written instructions. SECTION 06200 - FINISH CARPENTRY D. Wire Hangers: ASTM A 641, Class 1 zinc coating, soft temper, 0.162-inch diameter. A. Hardwood Trim: Provide finished hardwood lumber and moldings complying with the following requirements: E. Hanger Rods: Mild steel and zinc coated or protected with rust-inhibitive paint. G. Cementitious Backer Units: Finish according to manufacturer's written instructions. 1. Species: Clear, kiln-dried white hardwoods. 2. Species and Cut: Rift-sawn, clear, kiln-dried red oak selected for compatible grain and color. 3. Texture: Surfaced (smooth). 4. Lumber for Transparent Finish (Stained or Clear): Solid lumber stock. 5. Lumber for Painted Finish: Glued-up lumber or solid lumber stock. F. Steel Resilient Furring Channels: Manufacturer's standard product designed to reduce sound transmission, fabricated from steel sheet complying with ASTM A 653 or ASTM A 568 to form 1/2-inch-deep channel of the following configuration: 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 1. Single-Leg Configuration: Asymmetric-shaped channel with face connected to a single flange by a single-slotted leg (web). 2. Double-Leg Configuration: Hat-shaped channel with 1-1/2-inch-wide face connected to flanges by double-slotted or expanded-metal legs (webs). 3. Single- or Double-Leg Configuration: Asymmetric-shaped channel with face connected to a single flange by a single-slotted leg (web) or hat-shaped channel, with 1-1/2-inch-wide face connected to flanges by double-slotted or expanded-metal legs (webs). G. Grid Suspension System for Interior Ceilings: ASTM C 645, manufacturer's standard direct-hung grid suspension system composed of main beams and cross-furring members that interlock to form a modular supporting network. SPECIFICATIONS PROJECT NUMBER: 0213 DRAWING SCALE: AS NOTED SHEET NO: A13 SECTION 09680 - CARPET SECTION 09920 - INTERIOR PAINTING SECTION 09920 - INTERIOR PAINTING (Continued) 1.0 SUBMITTALS 1.0 SUMMARY 3. Low-Luster, Acrylic-Enamel Finish: 2 finish coats over a primer. A. This Section includes surface preparation and field painting of the following: 1.0 SUBMITTALS A. Product Data for each type of carpet material, carpet cushion, and installation accessory specified. Submit manufacturer's printed data on physical characteristics, durability, fade resistance, and fire-test-response characteristics. Submit methods of installation for each type of substrate. A. Samples for Verification: Full-size units of each type of ceiling assembly indicated; in sets for each color, texture, and pattern specified, showing the full range of variations expected in these characteristics. B. Shop Drawings showing columns, doorways, enclosing walls or partitions, built-in cabinets, and locations where cutouts are required in carpet. Indicate the following: ARCHITECT'S SPECIFICATIONS SECTION 09512 - ACOUSTICAL TILE CEILINGS 1. 6" square samples of each acoustical tile type, pattern, and color. 2. Set of 12-inch long samples of concealed suspension system members. 3. Set of 12-inch long samples of exposed moldings for each color and system type required. 1.1 ACOUSTICAL TILES, GENERAL A. Acoustical Tile Standard: Provide manufacturer's standard tiles of configuration indicated that comply with ASTM E 1264 classifications as designated by types, patterns, acoustical ratings, and light reflectances, unless otherwise indicated. 1.2 METAL SUSPENSION SYSTEMS, GENERAL A. Metal Suspension System Standard: Provide manufacturer's standard metal suspension systems of types, structural classifications, and finishes indicated that comply with applicable ASTM C 635 requirements. B. Finishes and Colors, General: Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes. Provide manufacturer's standard factory-applied finish for type of system indicated. 1. High-Humidity Finish: Comply with ASTM C 635 requirements for "Coating Classification for Severe Environment Performance" where high-humidity finishes are indicated. C. Attachment Devices: Size for five times design load indicated in ASTM C 635, Table 1, Direct Hung, unless otherwise indicated. 1. Postinstalled Powder-Actuated Fasteners in Concrete: Fastener system of type suitable for application indicated, fabricated from corrosion-resistant materials, with clips or other accessory devices for attaching hangers of type indicated, and with capability to sustain, without failure, a load equal to 10 times that imposed by ceiling construction, as determined by testing per ASTM E 1190, conducted by a qualified testing and inspecting agency. 1. Carpet type, color, and dye lot. 2. Locations where dye lot changes occur. 3. Seam locations, types, and methods. 4. Type of subfloor. 5. Type of installation. 6. Pattern type, repeat size, location, direction, and starting point. 7. Pile direction. 8. Type, color, and location of insets and borders. 9. Type of cushion, if specified. 10. Type, color, and location of edge, transition, and other accessory strips. 11. Transition details to other flooring materials. C. Samples for verification of the following products, in manufacturer's standard sizes, showing the full range of color, texture, and pattern variations expected. Prepare Samples from the same material to be used for the Work. Label each sample with manufacturer's name, material type, color, pattern, and designation indicated on Drawings and carpet schedule. Submit the following: 1. 24 -inch square Samples of each type of carpet material required. 2. 12-inch Samples of each type of exposed edge stripping and accessory item. 3. 6-inch Samples of each type of carpet cushion. 1. Exposed interior items and surfaces. 2. Surface preparation, priming, and finish coats specified in this Section are in addition to shop priming and surface treatment specified in other Sections. B. Paint exposed surfaces, except where the paint Schedule or elevations or details indicates that a surface or material is not to be painted or is to remain natural. If the paint Schedule does not specifically mention an item or a surface, paint the item or surface the same as similar adjacent materials or surfaces whether or not the Schedule indicates colors. If the Schedule does not indicate color or finish, the Architect will select from standard colors and finishes available. 1.2 SUBMITTALS A. Product Data: For each paint system specified. Include block fillers and primers. 1. Material List: Provide an inclusive list of required coating materials. Indicate each material and cross-reference specific coating, finish system, and application. Identify each material by manufacturer's catalog number and general classification. 2. Manufacturer's Information: Provide manufacturer's technical information, including label analysis and instructions for handling, storing, and applying each coating material proposed for use. 3. Certification by the manufacturer that products supplied comply with local regulations controlling use of volatile organic compounds (VOCs). B. Samples for Verification: Of each color and material to be applied, with texture to simulate actual conditions, on representative Samples of the actual substrate. 1. Provide stepped Samples, defining each separate coat, including block fillers and primers. Use representative colors when preparing Samples for review. Resubmit until required sheen, color, and texture are achieved. D. Schedule of carpet using same room designations indicated on Drawings. 1.3 PROJECT CONDITIONS E. Maintenance data for carpet and cushion to include in the operation and maintenance manual specified in Division 1. Include the following: 1. Methods for maintaining carpet and carpet cushion, including manufacturer's recommended frequency for maintaining carpet. 2. Precautions for cleaning materials and methods that could be detrimental to finishes and performance. Include cleaning and stain-removal products and procedures. D. Wire Hangers, Braces, and Ties: Provide wires complying with the following requirements: 1.1 QUALITY ASSURANCE A. Apply water-based paints only when the temperature of surfaces to be painted and surrounding air temperatures are between 50 and 90 deg F. B. Apply solvent-thinned paints only when the temperature of surfaces to be painted and surrounding air temperatures are between 45 and 95 deg F. C. Do not apply paint when the relative humidity exceeds 85 percent; or at temperatures less than 5 deg F above the dew point; or to damp or wet surfaces. 1. Zinc-Coated Carbon-Steel Wire: ASTM A 641/A 641M, Class 1 zinc coating, soft temper. 2. Size: Select wire diameter so its stress at three times hanger design load (ASTM C 635, Table 1, Direct Hung) will be less than yield stress of wire, but provide not less than 0.106-inch diameter wire. 1.3 INSTALLATION A. General: Install acoustical tile ceilings to comply with publications referenced below per manufacturer's written instructions and CISCA's "Ceiling Systems Handbook." 1. Standard for Ceiling Suspension System Installations: Comply with ASTM C 636. A. Installer Qualifications: Engage an experienced Installer who is certified by the Floor Covering Installation Board (FCIB) or who can demonstrate compliance with FCIB certification program requirements. B. Carpet Fire-Test-Response Characteristics: Provide carpet with the following fire-test-response characteristics as determined by testing identical products per test method indicated below by UL or another testing and inspecting agency acceptable to authorities having jurisdiction. Identify carpet with appropriate markings of applicable testing and inspecting agency. 1. Surface Flammability: Passes CPSC 16 CFR, Part 1630. 2. Flame Spread: 25 or less per ASTM E 84. 3. Smoke Developed: 450 or less per ASTM E 84. 2. U.B.C.'s "Metal Suspension Systems for Acoustical Tile and for Lay-in Panel Ceilings": U.B.C. Standard 25-2. 1.2 DELIVERY, STORAGE, AND HANDLING 1.4 MANUFACTURERS Products: Subject to compliance with requirements, provide one of the products in the paint Schedule. A. Manufacturers Names: The following manufacturers are referred to in the paint Schedule by use of shortened versions of their names, which are shown in parentheses: 1. Devoe & Raynolds Co. (Devoe). 2. Fuller-O'Brien Paints (Fuller). 3. Glidden Co. (The) (Glidden). 4. Benjamin Moore & Co. (Moore). 5. PPG Industries, Inc. (PPG). 6. Pratt & Lambert, Inc. (P & L). 7. Sherwin-Williams Co. (S-W). SECTION 09651 - RESILIENT TILE FLOORING A. General: Comply with the Carpet and Rug Institute's CRI 104, Section 5: "Storage and Handling." 1.5 PREPARATION A. Product Data: For each type of product specified. B. Deliver materials to Project site in original factory wrappings and containers, labeled with identification of manufacturer, brand name, and lot number. B. Samples for Verification: Full-size tiles of each different color and pattern of resilient floor tile specified, showing the full range of variations expected in these characteristics. C. Store materials on-site in original undamaged packages, inside well-ventilated area protected from weather, moisture, soilage, extreme temperatures, and humidity. Lay flat, with continuous blocking off ground. A. General: Remove hardware and hardware accessories, plates, machined surfaces, lighting fixtures, and similar items already installed that are not to be painted. If removal is impractical or impossible because of the size or weight of the item, provide surface-applied protection before surface preparation and painting. After completing painting operations in each space or area, reinstall items removed using workers skilled in the trades involved. a. Primer: Alkali-resistant, acrylic-latex, interior primer applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.0 mil. 1) Devoe: 50801 Wonder-Tones Interior Vinyl Latex Primer-Sealer. 2) Fuller: 220-20 Pro-Tech Interior Latex Wall Primer and Sealer. 3) Glidden: 5111 Spred Ultra Latex Primer-Sealer. 4) Moore: Regal First Coat Interior Latex Primer & Underbody #216. 5) PPG: 6-603 Speedhide Interior/Exterior Acrylic Latex Alkali Resistant Primer. 6) P & L: Z/F 1004 Suprime "4" Interior Latex Wall Primer. b. First and Second Coats: Low-luster (eggshell or satin), acrylic-latex, interior enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 2.8 mils. 1) Devoe: 34XX Wonder-Tones Interior Latex Eggshell Enamel. 2) Fuller: 212-XX AA Enamel Interior Acrylic Latex Eggshell Enamel. 3) Glidden: 4100 Series Spred Ultra Eggshell Latex Wall & Trim Paint. 4) Moore: Moore's Regal AquaVelvet #319. 5) PPG: 89 Line Manor Hall Eggshell Latex Wall and Trim Enamel. 6) P & L: Z/F 4000 Series Accolade Interior Velvet. 4. Semigloss, Acrylic-Enamel Finish: 2 finish coats over a primer. a. Primer: Alkali-resistant, acrylic-latex, interior primer applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.0 mil. 1) Devoe: 50801 Wonder-Tones Interior Vinyl Latex Primer-Sealer. 2) Fuller: 220-20 Pro-Tech Interior Latex Wall Primer and Sealer. 3) Glidden: Primer not required over this substrate. 4) Moore: Regal First Coat Interior Latex Primer & Underbody #216. 5) PPG: 6-603 Speedhide Interior/Exterior Acrylic Latex Alkali Resistant Primer on highly alkaline surfaces. 6) P & L: Z/F 1001 Suprime "1" 100 Percent Acrylic Multi-Purpose Primer. GARNETT ARCHITECTS, LLC ARCHITECTURE . PLANNING . INTERIOR DESIGN 140 SOUTH DEARBORN STREET, SUITE 410 CHICAGO, ILLINOIS 60603 312.447.0747 TEL 312.447.0748 FAX WWW.GARNETTARCHITECTS.COM b. First and Second Coats: Semigloss, acrylic-latex, interior enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 2.6 mils. 1) Devoe: 39XX Wonder-Tones Semi-Gloss Interior Latex Enamel. 2) Fuller: 214-XX AA Enamel Interior Acrylic Latex Semi-Gloss Enamel. 3) Glidden: 8200 Series Spred Ultra Latex Semi-Gloss Enamel. 4) Moore: Moore's Regal AquaGlo Vinyl-Acrylic Latex Enamel #333. 5) PPG: 88-110 Satinhide Interior Enamel Wall & Trim Lo-Lustre Semi-Gloss Latex. 6) P & L: Z/F 4100 Series Accolade Interior Semi-Gloss. 5. Semigloss, Alkyd-Enamel Finish: 2 finish coats over a primer. a. Primer: Alkali-resistant, alkyd- or latex-based, interior primer, as recommended by the manufacturer for this substrate, applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.0 mil. 1) Devoe: 51701 Wonder-Prime Interior All-Purpose Latex Primer Sealer & Vapor Barrier. 2) Fuller: 220-07 Interior Alkyd Enamel Undercoat. 3) Glidden: 5111 Spred Ultra Latex Primer-Sealer. 4) Moore: Regal First Coat Interior Latex Primer & Underbody #216. 5) PPG: 6-603 Speedhide Interior/Exterior Acrylic Latex Alkali Resistant Primer. 6) P & L: Z/F 1001 Suprime "1" 100 Percent Acrylic Multi-Purpose Primer. 7) S-W:. ProMar 200 Latex Wall Primer B28W200. 1.0 SUBMITTALS 1. For resilient accessories, manufacturer's standard-size samples, but not less than 12 long, of each resilient accessory color and pattern specified. 1.3 PROJECT CONDITIONS A. General: Comply with CRI 104, Section 6: "Site Conditions." C. Maintenance Data: For resilient floor tile to include in the maintenance manuals specified in Division 1. 1.1 RESILIENT TILE A. Rubber Floor Tile: Products complying with ASTM F 1344 and with requirements specified in the Resilient Tile Flooring Schedule. B. Vinyl Composition Floor Tile: Products complying with ASTM F 1066 and with requirements specified in the Resilient Tile Flooring Schedule. 1. Provide barrier coats over incompatible primers or remove and reprime. C. Subfloor Moisture Conditions: Moisture emission rate of not more than 3 lb/1000 sq. ft./24 hours when tested by calcium chloride moisture test in compliance with CRI 104, 6.2.1, with subfloor temperatures not less than 55 deg F. 2. Cementitious Materials: Prepare concrete, concrete masonry block, cement plaster, and mineral- fiber-reinforced cement panel surfaces to be painted. Remove efflorescence, chalk, dust, dirt, grease, oils, and release agents. Roughen as required to remove glaze. If hardeners or sealers have been used to improve curing, use mechanical methods of surface preparation. D. Subfloor Alkalinity Conditions: A pH range of 5 to 9 when subfloor is wetted with potable water and pHydrion paper is applied. 1.4 WARRANTY B. Rubber Accessory Moldings: Products complying with requirements specified in the Resilient Tile Flooring Schedule. 1.3 INSTALLATION ACCESSORIES A. Trowelable Leveling and Patching Compounds: Latex-modified, portland-cement-based formulation provided or approved by flooring manufacturer for applications indicated. B. Adhesives: Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions indicated. A. General Warranty: The special warranty specified in this Article shall not deprive the Owner of other rights the Owner may have under other provisions of the Contract Documents and shall be in addition to, and run concurrent with, other warranties made by the Contractor under requirements of the Contract Documents. B. Special Carpet Warranty: If used, submit a written warranty executed by carpet manufacturer and Installer agreeing to repair or replace carpet that does not meet requirements or that fails in materials or workmanship within the specified warranty period. Failures include, but are not limited to, more than 10 percent loss of face fiber, edge raveling, snags, runs, and delamination. C. Warranty Period: 10 years from date of Substantial Completion. 1.5 EXTRA MATERIALS SECTION 09653 - RESILIENT WALL BASE AND ACCESSORIES 1.0 SUBMITTALS C. Surface Preparation: Clean and prepare surfaces to be painted according to manufacturer's written instructions for each particular substrate condition and as specified. B. Space Enclosure and Environmental Limitations: Do not install carpet until work in space is completed and nominally dry, work above ceilings is complete, and ambient temperature and humidity conditions are and will be continuously maintained at values near those indicated for final occupancy. 1.2 RESILIENT ACCESSORIES A. Rubber Wall Base: Products complying with FS SS-W-40, Type I and with requirements specified in the Resilient Tile Flooring Schedule. B. Cleaning: Before applying paint or other surface treatments, clean the substrates of substances that could impair the bond of the various coatings. Remove oil and grease before cleaning. A. Furnish extra materials described below that match products installed, are packaged with protective covering for storage, and are identified with labels clearly describing contents. a. Use abrasive blast-cleaning methods if recommended by paint manufacturer. b. Determine alkalinity and moisture content of surfaces by performing appropriate tests. If surfaces are sufficiently alkaline to cause the finish paint to blister and burn, correct this condition before application. Do not paint surfaces where moisture content exceeds that permitted in manufacturer's written instructions. c. Clean concrete floors to be painted with a 5 percent solution of muriatic acid or other etching cleaner. Flush the floor with clean water to remove acid, neutralize with ammonia, rinse, allow to dry, and vacuum before painting. 3. Ferrous Metals: Clean ungalvanized ferrous-metal surfaces that have not been shop coated; remove oil, grease, dirt, loose mill scale, and other foreign substances. Use solvent or mechanical cleaning methods that comply with the Steel Structures Painting Council's (SSPC) recommendations. a. Blast steel surfaces clean as recommended by paint system manufacturer and according to requirements of SSPC-SP 10. b. Treat bare and sandblasted or pickled clean metal with a metal treatment wash coat before priming. c. Touch up bare areas and shop-applied prime coats that have been damaged. Wire-brush, clean with solvents recommended by paint manufacturer, and touch up with the same primer as the shop coat. 1.6 INTERIOR PAINT SCHEDULE A. Product Data: For each type of product specified. B. Samples for Verification: In manufacturer's standard sizes, but not less than 12 inches long, of each product color and pattern specified. 1. Carpet: Before installation begins, furnish quantity of full-width units equal to 5 percent of amount installed. PART 2 - PRODUCTS A. Concrete and Masonry (Other than Concrete Masonry Units): Provide the following paint systems over interior concrete and brick masonry surfaces: 2.0 CARPET 1. Flat Acrylic Finish: 2 finish coats over a primer. 1.1 RESILIENT WALL BASE A. Rubber Wall Base: Products complying with FS SS-W-40, Type I and with requirements specified in the Resilient Wall Base and Accessory Schedule. A. Products: Subject to compliance with requirements, provide one of the products specified in each carpet Product Data sheet at end of this Section. 2.1 INSTALLATION ACCESSORIES B. Vinyl Wall Base: Products complying with FS SS-W-40, Type II and with requirements specified in the Resilient Wall Base and Accessory Schedule. A. Trowelable Underlayments and Patching Compounds: As recommended by the carpet manufacturer. 1.2 INSTALLATION ACCESSORIES B. Adhesives: Water-resistant, mildew-resistant, nonstaining type to suit products and subfloor conditions indicated and to comply with flammability requirements for installed carpet as recommended by the carpet manufacturer. A. Adhesives: Water-resistant type recommended by manufacturer to suit resilient products and substrate conditions indicated. C. Seaming Cement: Hot-melt adhesive tape or similar product recommended by carpet manufacturer for taping seams and butting cut edges at backing to form secure seams and to prevent pile loss at seams. a. Primer: Alkali-resistant, acrylic-latex, interior primer applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.0 mil. 1) Devoe: 51701 Wonder-Prime Interior All-Purpose Latex Primer Sealer & Vapor Barrier. 2) Fuller: 220-17 Acrylic Concrete and Masonry Primer Sealer. 3) Glidden: 5111 Spred Ultra Latex Primer-Sealer. 4) Moore: Regal First Coat Interior Latex Primer & Underbody #216. 5) PPG: 6-2 Speedhide Interior Quick-Drying latex Sealer. 6) P & L: Z/F 1004 Suprime "4" Interior Latex Wall Primer. b. First and Second Coats: Flat, latex-based, interior paint applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 2.5 mils. 1.3 INSTALLATION A. General: Install resilient products according to manufacturer's written installation instructions. 1. Install wall base in lengths as long as practicable without gaps at seams and with tops of adjacent pieces aligned. A. General: Comply with carpet manufacturer's installation recommendations to prepare substrates indicated to receive carpet installation. B. Level subfloor within 1/4 inch in 10 feet, noncumulative, in all directions. Sand or grind protrusions, bumps, and ridges. Patch and repair cracks and rough areas. Fill depressions. 1) Devoe: 36XX Wonder-Tones Interior Latex Flat Wall Paint. 2) Fuller: 602-XX Liquid Velvet Latex Wall Paint. 3) Glidden: 4000 Series Spred Ultra Flat Latex Wall and Trim Paint. 4) Moore: Regal Wall Satin #215. 5) PPG: 80 Line Wallhide Interior Wall Flat Latex Paint. 6) P & L: Z/F 2000 Series Vapex Latex Flat Wall Finish. 2. Odorless, Flat Alkyd Finish: 2 finish coats over a primer. 2. Tightly adhere wall base to substrate throughout length of each piece, with base in continuous contact with horizontal and vertical substrates. 3. Form outside corners on job, from straight pieces of maximum lengths possible, without whitening at bends. Shave back of base at points where bends occur and remove strips perpendicular to length of base that are only deep enough to produce a snug fit without removing more than half the wall base thickness. 4. Form inside corners on job, from straight pieces of maximum lengths possible, by cutting an inverted V-shaped notch in toe of wall base at the point where corner is formed. Shave back of base where necessary to produce a snug fit to substrate. C. Place resilient products so they are butted to adjacent materials and bond to substrates with adhesive. Install reducer strips at edges of flooring that would otherwise be exposed. 1) Devoe: 50801 Wonder-Tones Interior Vinyl Latex Primer-Sealer. 2) Fuller: 220-20 Pro-Tech Interior Latex Wall Primer and Sealer. 3) Glidden: Primer not required over this substrate. 4) Moore: Regal First Coat Interior Latex Primer & Underbody #216. 5) PPG: 6-603 Speedhide Interior/Exterior Acrylic Latex Alkali Resistant Primer on highly alkaline surfaces. 6) P & L: Z/F 1001 Suprime "1" 100 Percent Acrylic Multi-Purpose Primer. c. First and Second Coats: Semigloss, acrylic-latex, interior enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 2.6 mils. 1) Devoe: 39XX Wonder-Tones Semi-Gloss Interior Latex Enamel. 2) Fuller: 214-XX AA Enamel Interior Acrylic Latex Semi-Gloss Enamel. 3) Glidden: 8200 Series Spred Ultra Latex Semi-Gloss Enamel. 4) Moore: Moore's Regal AquaGlo Vinyl-Acrylic Latex Enamel #333. 5) PPG: 88-110 Satinhide Interior Enamel Wall & Trim Lo-Lustre Semi-Gloss Latex. 6) P & L: Z/F 4100 Series Accolade Interior Semi-Gloss. 5. Semigloss, Alkyd-Enamel Finish: 2 finish coats over a primer. a. Primer: Alkali-resistant, alkyd- or latex-based, interior primer, as recommended by the manufacturer for this substrate, applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.0 mil. 1) Devoe: 51701 Wonder-Prime Interior All-Purpose Latex Primer Sealer & Vapor Barrier. 2) Fuller: 220-07 Interior Alkyd Enamel Undercoat. 3) Glidden: 5111 Spred Ultra Latex Primer-Sealer. 4) Moore: Regal First Coat Interior Latex Primer & Underbody #216. 5) PPG: 6-603 Speedhide Interior/Exterior Acrylic Latex Alkali Resistant Primer. 6) P & L: Z/F 1001 Suprime "1" 100 Percent Acrylic Multi-Purpose Primer. 7) S-W:. ProMar 200 Latex Wall Primer B28W200. b. First and Second Coats: Odorless, semigloss, alkyd, interior enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 2.6 mils. 1) Devoe: 26XX Velour Interior Alkyd Semi-Gloss Enamel. 2) Fuller: 206-XX Interior Alkyd Semi-Gloss Enamel. 3) Glidden: UH 8400 Ultra Traditional Alkyd Semi-Gloss Enamel. 4) Moore: Moore's Alkyd Dulamel #207. 5) PPG: 27 Line Wallhide Low Odor Interior Enamel Wall and Trim Semi-Gloss Oil. 6) P & L: S/D 5700 Cellu-Tone Alkyd Satin Enamel. 7) S-W: Classic 99 Interior Alkyd Semi-Gloss Enamel A-40 Series. A. Concrete Masonry Units: Provide the following finish systems over interior concrete masonry block units: Semigloss, Acrylic-Enamel Finish: 2 finish coats over a high-performance, latex-based, block filler. B. Gypsum Board: Provide the following finish systems over interior gypsum board surfaces: Flat Acrylic Finish: 2 finish coats over a latex-based, interior primer. C. Hollow Metal Window and Door Frames, Fire extinguisher Cabinets: Semigloss, Alkyd-Enamel Finish: One finish coat over an enamel undercoater and a quick-drying, rust-inhibitive, alkyd-based or epoxy-metal primer. SECTION 09950 - WALL COVERINGS 1.0 SUBMITTALS 2.2 PREPARATION B. Apply resilient wall base to walls, columns, pilasters, casework and cabinets in toe spaces, and other permanent fixtures in rooms and areas where base is required. b. First and Second Coats: Odorless, semigloss, alkyd, interior enamel applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 2.6 mils. 1. Use leveling and patching compounds to fill cracks, holes, and depressions in subfloor as recommended by the carpet manufacturer. C. Remove subfloor coatings, including curing compounds, and other substances that are incompatible with adhesives and that contain soap, wax, oil, or silicone. D. Broom or vacuum clean subfloors to be covered with carpet. Following cleaning, examine subfloors for moisture, alkaline salts, carbonation, or dust. 2.3 INSTALLATION a. Primer: Alkali-resistant, latex-based, interior primer applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 1.1 mils. 1) Devoe: 51701 Wonder-Prime Interior All-Purpose Latex Primer Sealer & Vapor Barrier. 2) Fuller: 220-20 Pro-Tech Latex Wall Primer Sealer, White. 3) Glidden: 5212 Glid-Guard Alkali-Resistant Primer. 4) Moore: Regal First Coat Interior Latex Primer & Underbody #216. 5) PPG: 6-2 Speedhide Interior Quick-Drying Latex Sealer. 6) P & L: Z/F 1004 Suprime "4" Interior Latex Wall Primer. 7) S-W: ProMar 200 Interior Latex Wall Primer B28W200. A. Samples for verification in sets for each color, texture, and pattern specified, showing the full range of variations expected in these characteristics. 1. Wall Covering Material: Full-width sample, not less than 36 inches long, from dye lot used for the Work. Mark the top and face of material. A. Maintenance data for wall covering to include in the operation and maintenance manual specified in Division 1. 1.1 QUALITY ASSURANCE A. Fire-Test-Response Characteristics: Provide wall coverings with the following surface-burning characteristics as determined by testing identical products per ASTM E 84 by UL or another testing and inspecting agency acceptable to authorities having jurisdiction. 1. Flame Spread: 25 or less. 2. Smoke Developed: 450 or less. B. Comply with carpet manufacturer's recommendations for seam locations and direction of carpet; maintain uniformity of carpet direction and lay of pile. At doorways, center seams under door in closed position. Do not bridge building expansion joints with continuous carpet. C. Cut and fit carpet to butt tightly to vertical surfaces, permanent fixtures, and built-in furniture including cabinets, pipes, outlets, edgings, thresholds, and nosings. Bind or seal cut edges as recommended by carpet manufacturer. D. Extend carpet into toe spaces, door reveals, closets, open-bottomed obstructions, removable flanges, alcoves, and similar openings. E. Install pattern as shown on the finish plans. - 1.2 ADHESIVES A. Direct Glue-Down Installation: Comply with CRI 104, Section 8: "Direct Glue-Down." NO. b. First and Second Coats: Odorless, flat, alkyd, interior paint applied at spreading rate recommended by the manufacturer to achieve a total dry film thickness of not less than 3.0 mils. 1) Devoe: 21XX Velour Interior Alkyd Flat Wall Paint. 2) Fuller: 101-XX Liquid Velvet Alkyd Flat Wall Paint. 3) Glidden: 5700 Ultra-Hide Alkyd Flat Wall Enamel. 4) Moore: Moore's Alkyd Sani-Flat #204. 5) PPG: 6-50 Series Speedhide Alkyd Flat Enamel. 6) P & L: S/D 6700 Series Lyt-All Flowing Flat.f 7) S-W: ProMar 200 Alkyd Flat Wall Paint B32W201. 03/13/15 ISSUED FOR BID AND PERMIT DATE REVISION A. General: Mildew-resistant, nonstaining adhesive, for use with specific wood-veneer wall covering and substrate application, as recommended by wall covering manufacturer. 1.3 PREPARATION A. Prepare substrates to achieve a smooth, dry, clean surface free of flaking, unsound coatings, cracks, and defects. 1. Painted Surfaces: Treat areas susceptible to pigment bleeding. 2. Metals: If not factory primed, clean and apply rust-inhibitive zinc primer. 3. Moisture Content: Maximum of 5 percent on new plaster, concrete, and concrete masonry units when tested with an electronic moisture meter. 4. Prime new gypsum board with primer recommended by wall covering manufacturer. 5. Allow new plaster to cure. Treat areas of high alkalinity. 10 NORTH DEARBORN STREET 8TH FLOOR CHICAGO, ILLINOIS 60602 2.4 CLEANING 1.4 INSTALLATION, GENERAL A. Perform the following operations immediately after completing installation. 1. Remove visible adhesive, seam sealer, and other surface blemishes using cleaner recommended by carpet manufacturer. 2. Remove protruding yarns from carpet surface. 3. Vacuum carpet using commercial machine with face-beater element. A. General: Comply with wall coverings manufacturers' written installation instructions applicable to products and applications indicated, except where more stringent requirements apply. SPECIFICATIONS B. Match pattern 72 inches above finish floor. 2.5 PROTECTION C. Install seams vertical and plumb at least 6 inches from outside corners and 3 inches from inside corners. No horizontal seams. A. General: Comply with CRI 104, Section 15: "Protection of Indoor Installation." D. Remove air bubbles, wrinkles, blisters, and other defects. B. Provide final protection and maintain conditions, in a manner acceptable to manufacturer and Installer, that ensure carpet is without damage or deterioration at the time of Substantial Completion. E. Trim edges for color uniformity, pattern match, and tight closure at seams and edges. Butt seams. PROJECT NUMBER: 0213 DRAWING SCALE: AS NOTED SHEET NO: A14