Lloydminster & District Co-op Admin Building ADDENDUM #2 Lloydminster, SK SECTION 00 00 02 R.K.E. File 13-496 Page 1 of 2 General This Addendum will be attached to and form part of the Contract Documents. It is the responsibility of Contractors and bidders to ensure that their subcontractors are familiar with all items included in this Addendum. This addendum contains a total of 3 pages, including sketches. A2.1 Specifications A2.1.1 .1 A2.2 Ref: Section 26 27 28: Electric Heat Electrical contractor to provide and install all control wiring for 24 volt low voltage relays and remote thermostats. Co-op Drawings A2.2.1 .1 .2 Ref: Drawing A8.0: Interior Elevations Plan 1: 2nd Floor Plan: Clarification: Closet 220.1 is to come with closet rod and shelf. Elevation 13: Clarification: Glass doors to be flush with cabinet doors below. A2.2.2 .1 Ref: Drawing M8.3: Specifications Lavatory L-1 shall be revised to read as follows: “L-1 (Barrier Free): Equal to Crane model 1280V, self-rimming counter top vitreous china lavatory to be complete with mounting hardware, off-set waste assembly and insulated supply and waste assemblies with Handi-Lav-Guard by Truebro Inc. Delta Commercial model 21C-133 trim. Acceptable equivalents: American Standard, Briggs, Kohler.” A2.2.3 .1 Ref: Drawing E1.1: Site Plan See attached S(E1.1)R2 for revised circuit designation of vehicle pedestals (two stalls per circuit) and revised cable quantities. A2.2.4 .1 Ref: Drawing E2.1: Lighting Plan Revise Type DD to read: 1220 TWO LAMP WALL MOUNTED FLUORESCENT C/W WHITE POWDER COAT FINISH REFLECTOR, DIE-FORMED COLD ROLLED STEEL HOUSING, WHITE OPAL LENS AND ELECTRONIC BALLAST. CORELITE #AW-WO-2T8-1C-UNV OR APPROVED EQUIVALENT C/W 2-F32T8/835 LAMPS 120V .2 Revise Type 1 Luminaire to read: LED EXTERIOR WALL MOUNT LUMINAIRE C/W MIN. 1600 DELIVERED LUMENS, EPOXY-COATED DIE-CAST ALUMINUM HOUSING AND BACKPLATE, UPLIGHT AND DOWNLIGHT, DIFFUSED TEMPERED GLASS OR ACRYLIC LENS, BRUSHED ALUMINUM FINISH, 4000°K COLOUR TEMPERATURE. LUMIERE “EON” #303-W2-LEDB2-4000-UNV-T2-BA TMS LIGHTING #GE625-A-1-F18 120V. A2.2.5 .1 Ref: Drawing E7.1: Single Line Diagram and Details Delete 12-15A1P breakers from Panel A and replace with spares. Subject to compliance with the requirements, the following items indicated as Approved may be incorporated into the Work. Approved Equivalents: Architectural Specified Approved Equivalent Section 08 12 00 Automatic Door Opener GyroTech Model GT 8500, Stanley Magic Force Lloydminster & District Co-op Admin Building Lloydminster, SK R.K.E. File 13-496 ADDENDUM #2 SECTION 00 00 02 Page 2 of 2 Approved Equivalents: Mechanical, Drawing M8.2 & M8.3 Specified Approved Equivalent Crane, American Standard, Zurn, Kohler (Water Closets) Contrac, Mansfield Non-specified drainage and supplies Delta Commercial Crane, American Standard, Zurn, Kohler (Lavatories) Contrac, Mansfield Fiat (Mop Sinks) Acorn, Zurn Crane, American Standard, Zurn (Urinals) Contrac, Mansfield, Kohler Delta (S-1 & S-2 trim) Zurn, Symmons, Kohler, Sloan MiFab (Floor drains, trap primers, cleanouts) Zurn, Watts Conbraco (backflow preventors) Zurn Wilkins, Watts Watts (thermal expansion tank) Zurn Wilkins Price (Louvers) Ventex, Westvent Tamco (Control Dampers) Alumavent Price, Ruskin, Greenheck (Fire dampers) Nailor Lennox York, Armstrong, Carrier Aeromatic (HRV’s) Lifebreath, Venmar Price (Grilles, Diffusers, Registers) Titus, Krueger Cook Broan Commercial, PennBarry Barnes (Sump Pumps) Bell & Gossett Approved Equivalents: Electrical Item Type BB Manufacturer Focal Point, Pinnacle Type CC Visioneering, PMC Lighting Type DD HE Williams Type A Philips Type B Maxilite Type C Philips, Juno Ceiling Occupancy Sensors Greengate Wall Occupancy Sensors Greengate, Hubbell Baseboard Heaters Stelpro Emergency Lighting Beghelli Exit Lighting Beghelli - End of Addendum #2 -