LLE-3 • LLE-6 - Digital Lumens

advertisement
Date:
Type:
Firm:
Project:
LLE-3 • LLE-6
Intelligent LED Linear Product Family
PRODUCT FAMILY FEATURES
• Granular controls for fine-tuning of lighting settings
• Wireless compatibility with LightRules ® software
• Control flexibility for individual or group management
• Diffuse optics eliminate point sources and glare
• Digital Lumens’ signature intelligence — occupancy sensing,
daylight sensing, logging of all key energy and occupancy data
• No glass or mercury
LLE-3 • LLE-6
with DL A-LLE
DLA SENSING
& CONTROL
Onboard Intelligence
Sensor Inputs
Modular sensing with data logging
Energy and fault monitoring
Modular occupancy sensor (PIR)
Modular daylight sensor
Wireless Networking Zigbee Compliant Platform/802.15.4
®
Control Capabilities
Dimming
Scheduling via LightRules
kWh and occupancy logging
Daylight harvesting
LLE-3 • LLE-6
0-100%, 16-bit resolution
without DL A-LLE
ENVIRONMENTAL
Operating Temp. 14° to 104° F (-10° to 40°C)
Humidity
0-95%, non-condensing
CERTIFICATION
& WARRANTY
Certifications
UL 1598, cUL, UL-MX NOM, CE, DLC, FCC
Part 15 Class B, CISPR 15
Pending
Certifications
C-Tick
Warranty
www.digitallumens.com
+1 (617 ) 723-1200
DLA-LLE
Five-year limited warranty
14°F
Min
104°F
Max
-10°C
Min
40°C
Max
Intelligent LED Linear Product Family
LLE-3-ST • LLE-6-ST
FIXTURE SPECIFICATIONS
PERFORMANCE
LLE-3-ST
1
LLE-6-ST
5000K
4000K
5000K
4000K
Lumen Output 2,893 lm
2,965 lm
5,930 lm
5,897 lm
32 W
59 W
60 W
93 lm/W
101 lm/W 97 lm/W
Power Consumption 30 W
Efficacy 96 lm/W
120-277 VAC,
50-60 Hz, 0.27 A
Input Ratings 2
120-277 VAC,
50-60 Hz, 0.50 A
POLAR CANDELA
DISTRIBUTION
Diffuse Optic
LLE-3-ST
•5000 Kelvin CCT ("-850")
•4000 Kelvin CCT ("-840")
Color Temperature 3
CRI 80 minimum, 82 typical
Lumen Maintenance L70 (10K): 60,000 hours
L70 calculated: 60,000+ hours
(LM-80) @ 104°F (40°C) 4
Power Factor 0.9 minimum
Surge Protection Per IEC 61547
LLE-6-ST
LLE-3-ST
PHYSICAL
Fixture Only:
Fixture Only:
Fixture with DL A-LLE:
Fixture with DL A-LLE:
6.6 lbs (3.0 kg)
Weight
LLE-6-ST
7.1 lbs (3.2 kg)
7.3 lbs (3.3 kg)
7.7 lbs (3.5 kg)
Fixture Only: 5
Dimensions 4.0 x 3.7 x 48.5 in (10.9 x 9.3 x 123.2 cm)
(H x W x D) Fixture with DL A-LLE:
4.9 x 3.8 x 51.3 in (12.4 x 9.7 x 130.2 cm)
Fixture only 5
•Standard aircraft cable
•Fixed mount
Mounting Options
Diffuse Optic
6
LLE-3-ST
LLE-6-ST
1.24
1.32
End View
Individual f ixture performance may vary
Voltage ratings may vary for international certif ications
3
Nominal CCT, as def ined by ANSI C78.377-2008
4
Projected, based on TM-21 data. L 70 = Time to 70% lumen maintenance. Refer to
the Statement of Lumen Maintenance available online at digitallumens.zendesk.com
5
LLE f ixture length is 48 in (122 cm) when mounted end to end
6
Ratio of f ixture spacing to mounting height
2
4.0 in
(10.9 cm)
Fixture with DLA-LLE
51.3 in
(130.2 cm)
1
3.7 in
(9.3 cm)
48.5 in
(123.2 cm)
PC lens, PC/ABS endcaps, powder coated
Enclosure
steel and aluminum
SPACING CRITERIA
LLE-3-ST & LLE-6-ST
DIMENSIONS
3.8 in
(9.7 cm)
4.9 in
(12.4 cm)
Intelligent LED Linear Product Family
LLE-3-ST • LLE-6-ST
DLA-LLE SPECIFICATIONS
PERFORMANCE
DIMENSIONS
DLA-LLE
Input Voltage 12-24 VDC
2.8 in
(7.1 cm)
Power Consumption <0.5 W
Connections
•DC (Power)
•DALI (Data)
4.9 in
(12.4 cm)
PHYSICAL
Dimensions
4.9 x 3.8 x 2.8 in (12.4 x 9.7 x 7.1 cm)
(H x W x D)
Side View
Weight 8.6 oz (243.8 g)
Top View
Enclosure PC/ABS, powder coated steel and aluminum
Front View
Bottom View
3.8 in
(9.7 cm)
SENSOR COVER AGE
Top View
Side View
0
12 ft
(3.7 m)
24 ft
(7.3 m)
0
14 ft
8 ft
3 ft
3 ft
8 ft
14 ft
(4.3 m) (2.4 m) (0.9 m) (0.9 m) (2.4 m) (4.3 m)
24 ft
(7.3 m)
WIRING SCHEMATIC
Each fixture contains line power leads that connect to either the power source or to an adjacent fixture. Additionally, control data
and power wires are provided to connect to the Digital Light Agent.
CONTROL
Power (black/red)
Data (yellow/white)
LINE POWER
Line (brown)
Ground (green/yellow)
Neutral (blue)
LLE/DLA-LLE SCHEMATIC
Fixtures can be installed and wired end-to-end in a multi-fixture run, or as standalone units. Each DLA can control up to fifteen LLE
fixtures. The number of DLA modules installed in a fixture run will depend on preference and room characteristics.
DLA-LLE GROUP 1
DLA-LLE GROUP 2
DLA-LLE GROUP 3
DLA-LLE GROUP 4
DLA-LLE GROUP 5
ORDERING INFORMATION
The tables below list item numbers for the LLE fixture family:
LLE
LLE-3
FIXTURE TYPE ►
LLE-6
OPTIC ▼
5000K CCT
4000K CCT
5000K CCT
4000K CCT
Diffuse
LLE-3-ST-D-850
LLE-3-ST-D-840
LLE-6-ST-D-850
LLE-6-ST-D-840
DLA-LLE
CATEGORY
Modular
Control
PART NUMBER
DLA-LLE-S
PART DESCRIPTION
Digital Light Agent for LLE,
Symmetric Motion Sensor
HANGING HARDWARE
CATEGORY
PART NUMBER
PART DESCRIPTION
LHHAS
Standard Aircraft Cable Hanging Hardware
(includes cables, fasteners, and spring clips for
five fixtures)
LHHRM
Fixed Mount Hanging Hardware (includes
mounting brackets and locking screws for
five fixtures)
LLE Hanging
Hardware
www.digitallumens.com
374 Congress Street, Suite 600
Boston, MA USA 02210
+1 (617) 723-1200
Standard Aircraft Cable
Fixed Mount
All Rights Reser ved © 2010-2015
Digital Lumens Incorporated
Subject to change without notice.
DOC-000258-00 Rev E 01-15