Installation Instructions (USA only) MODELS DSKS433 AND DSKS333 MUST BE INSTALLED WITH CONTROL PANEL AT BOTTOM IN ORDER TO OPERATE ADEQUATELY. Questions? Call: 800.GE.CARES (US) or visit our web site at: www.GEAppliances.com (US) BEFORE YOU BEGIN Read these instructions completely and carefully. • IMPORTANT- Save these instructions for local inspector’s use. • IMPORTANT- Observe all governing codes and ordinances. • Note to Installer -%HVXUHWROHDYHWKHVHLQVWUXFWLRQV with the customer. • Note to Customer - Keep these instructions with your Owner’s Manual for future reference. %HIRUH WKH ROG GU\HU LV UHPRYHG IURP VHUYLFH RU discarded, remove the dryer door. • Service information and the wiring diagram are located in the control console. • Do not allow children on or in the appliance. Close supervision of children is necessary when the appliance is used near children. ,QVWDOO WKH GU\HU ZKHUH WKH WHPSHUDWXUH LV DERYH ) for satisfactory operation of the dryer control system. • Product failure due to improper installation is not covered under the Warranty. 'U\HUV LQVWDOOHG LQ JDUDJHV LI DOORZHG E\ ORFDO FRGHV PXVWEHHOHYDWHGLQFKHVFPDERYHWKHÀRRU WARNING RISK OF FIRE • To reduce the risk of severe injury or death, follow all installation instructions. &ORWKHV GU\HU LQVWDOODWLRQ PXVW EH SHUIRUPHG E\ D TXDOL¿HG installer. • Install the clothes dryer according to these instructions and in accordance with local codes. In the absence of local codes, installation must comply with the NATIONAL ELECTRICAL CODE, ANSI/NFPA NO. 70. • This dryer must be exhausted to the outdoors. • Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors. '2 127 LQVWDOO D FORWKHV GU\HU ZLWK ÀH[LEOH SODVWLF GXFWLQJ PDWHULDOV ,I ÀH[LEOH PHWDO VHPLULJLG RU IRLOW\SH GXFW LV installed, it must be UL listed and installed in accordance with the instructions found in “Connecting The Dryer To House Vent” on page 4 of this manual. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will REVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH • Do not install or store this appliance in any location where it could be exposed to water and or weather. 6DYH WKHVH LQVWUXFWLRQV ,QVWDOOHUV %H VXUH WR OHDYH WKHVH LQVWUXFWLRQVZLWKWKHFXVWRPHU DETERMINE ELECTRICAL REQUIREMENTS FOR YOUR DRYER MODEL 7KLVGU\HUPXVWEHFRQQHFWHGWRDQLQGLYLGXDOEUDQFKFLUFXLWRISURSHUYROWDJHDQGIUHTXHQF\DVVSHFL¿HGRQ5DWLQJ3ODWHORFDWHGLQVLGH GU\HUGRRUZLWKQRRWKHUDSSOLDQFHVRU¿[WXUHVDWWDFKHG (;&(37,21 $ 9 UHFHSWDFOH LV ORFDWHG RQ WKH EDFN RQ WKH GU\HU DQG LV DYDLODEOH RQO\ IRU XVH ZLWK D ZDVKHU WKDW LV DȻ[HG WR WKH GU\HU ZLWK D :')NLW,WPD\QRWEHXVHGIRUDQ\RWKHUDSSOLDQFHRUDQ\FRQGLWLRQVRWKHUWKDQVWDWHGDERYH99PRGHOVRQO\ %UDQFKFLUFXLWPXVWEHSURWHFWHGE\WKHUHTXLUHGWLPHGHOD\IXVHVRUFLUFXLWEUHDNHUV9RU9LQVWDOODWLRQDPSV9LQVWDOODWLRQRUDPSV • The electrical installation must conform to the national and local codes. 208V AND 240V MODELS ARE NOT APPROVED FOR 120V INSTALLATION. TOOLS YOU WILL NEED MATERIALS YOU WILL NEED SLIP JOINT PLIERS FLAT BLADE AND PHILLIPS SCREWDRIVERS 4" DIA. METAL DUCT (RECOMMENDED) STACKING KITS FOR DRYERS (Comes with individual Installation Instructions) Over washer - Use Wall Mount Kit WMK-35 or - Stack Rack DSDR24 or - Stack Rack DSR-24 For alcove and closet depth and width UHTXLUHPHQWVVHHVSHFL¿FNLWLQVWUXFWLRQV All stacking kits are available from your local sales outlet. 4" DUCT CLAMPS (2) OR 4" DIA. FLEXIBLE METAL (SEMI-RIGID) UL LISTED TRANSITION DUCT (IF NEEDED) 4" SPRING KIT WX08X10077 (INCLUDES 2 ELBOWS) CLAMPS (2) 4" DIA. FLEXIBLE METAL (FOIL TYPE) UL LISTED TRANSITION DUCT (IF NEEDED.) EXHAUST HOOD SAFETY GLASSES DRYER POWER CORD KIT (NOT PROVIDED WITH DRYER) UL RATED 120/240V,30A 4" DIA. METAL 3/4" STRAIN RELIEF WITH 3 OR 4 PRONGS. UL RECOGNIZED IDENTIFY THE PLUG ELBOW TYPE AS PER THE HOUSE RECEPTACLE BEFORE PURCHASING LINE CORD. GLOVES DUCT TAPE UNPACKING AND PREPARING FOR INSTALLATION Prepare the area and exhaust for installation of new dryer. &KHFNDQGHQVXUHWKHH[LVWLQJH[WHUQDOH[KDXVWLVFOHDQDQGPHHWVDWWDFKHGLQVWDOODWLRQVSHFL¿FDWLRQV Remove the literature and accessories bag from the dryer drum. Place the literature in a convenient place. Using foam pads from dryer carton, turn dryer upside down as shown. Install knobs. For location, refer to the Owner’s Manual. Dryer is now ready to be mounted above washer using accessory kit. Remove the foam shipping pads from under dryer. Move the dryer to the desired location. Follow the steps in the following pages to connect the dryer to the external exhaust and power supply. Printed in Mexico 234D2017P001 31-16710 02-13 GE ELECTRICAL CONNECTION DETAILS OBSERVE ALL GOVERNING CODES AND ORDINANCES GROUNDING INSTRUCTIONS •7KH RSHUDWLQJ YROWDJH 9ROWV $PSHUDJH $PSV DQG )UHTXHQF\ +] RI WKLV GU\HU DUH LQGLFDWHG RQ WKH 5DWLQJ Plate located to the right of the loading port. • Connect this dryer to a circuit corresponding to that indicated on Rating Plate and protected by fuses or a circuit breaker in accordance with local codes. • Use a power supply cord kit marked for use with clothes GU\HU)RU9DQG9PRGHOVXVHDSRZHUVXSSO\FRUG kit marked for use with clothes dryers. DO NOT USE EXTENSION CORD WITH THIS APPLIANCE )RUDOWHUQDWH9RU9SRZHUVXSSO\KRRNXSSURFHHG DVIROORZV • Connect supply wire leads to terminal block as shown on sketch below, depending on type of installation. • Make sure screws on terminal block are tight. This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electrical current. WARNING: Improper connection of the equipment grounding conductor can result in a risk of electric VKRFN&KHFNZLWKDTXDOL¿HGHOHFWULFLDQRUVHUYLFHPDQLI\RX are in doubt as to whether the appliance is properly grounded. 'RQRWPRGLI\WKHSOXJSURYLGHGZLWKWKHDSSOLDQFHLILWZLOOQRW¿W WKHRXWOHWKDYHDSURSHURXWOHWLQVWDOOHGE\DTXDOL¿HGHOHFWULFLDQ WARNING: Appliance grounded to neutral conductor through a link. If used in a mobile home, a new construction, a recreational vehicle or if local codes do not SHUPLWJURXQGLQJWKURXJKQHXWUDODFRQGXFWRUFRUGRUFDEOH assembly for use with clothes dryers must be used with the IROORZLQJ VSHFL¿FDWLRQV 7\SH 6W &DEOH 0LQ 9ROW $PS ZLWK FORVHGORRS WHUPLQDOV DQG VHFXUHG ZLWK D 8/ recognized strain relief. See manufacturer’s instructions. FOR THREE-WIRE SUPPLY FOR FOUR-WIRE SUPPLY (208V & 240V MODELS) • Remove terminal block cover. &RQQHFWWZR+27OLQHVWRRXWHUVFUHZV/DQG/RI terminal block. POWER SUPPLY • Connect Neutral line to center &25'$:* VFUHZ1RIWHUPLQDOEORFN MINIMUM COPPER White Neutral Wire Hot Wire *UHHQ *URXQGLQJ Screw *URXQG Strap Hot Wire CONDUCTORS $039 WITH TYPE UL 5(&2*1,=(' MINIMUM RATED & 2592/7 23(5$7,21 OR 120/240 VOLT 6833/<86(21/< $03)86(6 (208V & 240V MODELS) • Remove terminal block cover. 5HPRYHJURXQGVWUDSDQGGLVFDUG5HVFUHZJUHHQ grounding screw in place. &RQQHFWWZR+27OLQHVWRRXWHUVFUHZV/DQG/RI terminal block. &RQQHFW1HXWUDOOLQHWRFHQWHUVFUHZ1RIWHUPLQDOEORFN • Attach ground wire of power supply to green grounding screw POWER SUPPLY CORD beside terminal block. *UHHQRU<HOORZ $:*0,1,080 *UHHQ*URXQGLQJ6FUHZ *URXQG:LUH Hot Wire Hot Wire FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. White Neutral Wire &233(5&21'8&7256 $039:,7+&/26(' LOOP TERMINALS TYPE UL 5(&2*1,=('0,1,080 5$7('& 5(029(*5281'675$3 $1'',6&$5'25 92/723(5$7,2125 92/76833/<86( 21/<$03)86(6 FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. • Properly strain relief the cordset or cable to the cable entry hole with UL recognized strain relief. • Replace terminal block cover. • Properly strain relief the cordset or cable to the cable entry hole with UL recognized strain relief. • Replace terminal block cover. 3 WIRE RECEPTACLE (10-30R) X Typical 30 amp receptacle for use where local codes permit use of flexible type power supply cord (pigtail). G W Y 4-WIRE RECEPTACLE (14-30R) Typical 30 amp receptacle for use where local codes permit use of flexible type power supply cord (pigtail). 2 4-CONDUCTOR CORD ASSEMBLY ( Type ST Cable) Typical 30 amp cord assembly for use where local codes do not permit grounding through neutral. EXHAUST INFORMATION (DFKWXUQRYHUVKRXOGEHWUHDWHGDVRQHWXUQ WARNING - SEALING OF JOINTS IN CANADA AND IN THE UNITED STATES, THE REQUIRED EXHAUST DUCT DIAMETER IS 4 in (102mm). DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE. • All joints should be tight to avoid leaks. The male end of each section of duct must point away from the dryer. • The duct shall not be assembled with screws or other fastening means that extend into the duct and catch lint. 'XFWMRLQWVFDQEHPDGHDLUDQGPRLVWXUHWLJKWE\ZUDSSLQJWKH overlapped joints with duct tape. • Horizontal runs should slope down toward the outdoors 1/4 inch per foot. 8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO • Increase the drying times and the energy cost. • Reduce the dryer life. $FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG WARNING - INSULATION BEFORE PERFORMING THIS EXHAUST INSTALLATION, BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY. Ductwork that runs through an unheated area or is near air conditioning VKRXOGEHLQVXODWHGWRUHGXFHFRQGHQVDWLRQDQGOLQWEXLOGXS EXHAUST CONNECTION WARNING - TO REDUCE THE RISK OF FIRE OR PERSONAL INJURY: The correct exhaust installation is YOUR RESPONSIBILITY. Problems due to incorrect installation are not covered by the warranty. Remove and discard existing plastic or metal foil transition duct and UHSODFHZLWK8/OLVWHGWUDQVLWLRQGXFW The MAXIMUM ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct, number of turns, the W\SHRIH[KDXVWKRRGZDOOFDSDQGDOOFRQGLWLRQVQRWHGEHORZ7KH maximum duct length for rigid metal duct is shown in the table on the next page. • This clothes dryer must be exhausted to the outdoors. • Use only 4” rigid metal ducting for the home exhaust duct. 8VH RQO\ µ ULJLG PHWDO RU 8/OLVWHG ÀH[LEOH PHWDO VHPLULJLG RU IRLOW\SH GXFW WR FRQQHFW WKH GU\HU WR WKH KRPH H[KDXVW GXFW It must be installed in accordance with the instructions found in “Connecting the Dryer to House Vent” on page 4 of this manual. • Do not terminate exhaust in a chimney, a wall, a ceiling, gas YHQWFUDZOVSDFHDWWLFXQGHUDQHQFORVHGÀRRURULQDQ\RWKHU concealed space of a building. The accumulated lint could create DSRWHQWLDO¿UHKD]DUG • Never terminate the exhaust into a common duct with a kitchen exhaust system. A combination of grease and lint creates a SRWHQWLDO¿UHKD]DUG 'RQRWXVHGXFWORQJHUWKDQVSHFL¿HGLQWKHH[KDXVWOHQJWKWDEOH /RQJHUGXFWVFDQDFFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG • Never install a screen in or over the exhaust duct. This will cause OLQWWRDFFXPXODWHFUHDWLQJDSRWHQWLDO¿UHKD]DUG • Do not assemble ductwork with any fasteners that extend into the duct. These fasteners can accumulate lint, creating a potential ¿UHKD]DUG • Do not obstruct incoming or exhausted air. • Provide an access for inspection and cleaning of the exhaust system, especially at turns and joints. Exhaust system shall be inspected and cleaned at least once a year. EXHAUST SYSTEM CHECK LIST HOOD OR WALL CAP • Terminate in a manner to prevent back drafts or entry of birds or other wildlife. • Termination should present minimal resistance to the exhaust DLU ÀRZ DQG VKRXOG UHTXLUH OLWWOH RU QR PDLQWHQDQFH WR SUHYHQW clogging. • Never install a screen in or over the exhaust duct. This could cause lint build up. • Wall caps must be installed at least 12 in. above ground level or any other obstruction with the opening pointed down. SEPARATION OF TURNS For best performance, separate all turns by at least 4 ft. of straight duct, including distance between last turn and exhaust hood. TURNS OTHER THAN 90º 2QHWXUQRIRUOHVVPD\EHLJQRUHG 7ZRWXUQVVKRXOGEHWUHDWHGDVRQHWXUQ ALTERNATE EXHAUST INSTRUCTIONS IF YOUR DRYER COMES WITH REAR EXHAUST, TO CHANGE TO SIDE OR BOTTOM EXHAUST: IF YOUR DRYER COMES WITH TOP EXHAUST, TO CHANGE TO SIDE OR REAR EXHAUST: 6” Left knockout • Remove rear access panel. • Remove access panel at back of dryer to gain access 'LVFRQQHFW UHWDLQLQJ SODWH DQG HOERZ E\ UHPRYLQJ to internal ducts. 203 mm Blower (8”) mounting screw from the chassis and remove tape • Disconnect duct exhaust from blower housing securing elbow to blower housing. UHPRYHWDSHVHFXULQJGXFW • Remove cover plate from rear access panel and place FOR SIDE EXHAUST: Bottom over top exhaust opening. knockout 5HPRYHGHVLUHGNQRFNRXWSODWHHLWKHUULJKWRUOHIWVLGH FOR SIDE EXHAUST: &XWDPPòµOHQJWKRIPPµGLDULJLG Right knockout 5HPRYHGHVLUHGNQRFNRXWSODWHHLWKHUULJKWRUOHIWVLGH 89 mm GXFWDVVKRZQUHPRYHEXUUVIURPFXWHGJH 7DNH WKH GXFW SUHYLRXVO\ UHPRYHG DQG FXW D PP (3½”) • Attach this extension duct to blower housing duct. òµ OHQJWK RI PP µ GLD ULJLG GXFW DV VKRZQ $WWDFKDHOERZIDFLQJGHVLUHGRSHQLQJ 295 mm (11½”) UHPRYHEXUUVIURPFXWHGJH For Rear Exhaust $WWDFKDVHFWLRQRIPPµGLDULJLGGXFW 115 mm (4½”) • Attach this extension duct to blower housing duct. For Side Exhaust to elbow to protrude through side of cabinet. $WWDFKWKHHOERZIDFLQJGHVLUHGRSHQLQJ • Seal all joints with duct tape. $WWDFKDVHFWLRQRIPPµGLDULJLGGXFWWRHOERZWR Rigid • Reinstall rear access panel. Metallic protrude through side of cabinet. Ducting FOR BOTTOM EXHAUST: Cut Here • Seal all joints with duct tape. • Remove cover plate at bottom of dryer. • Reinstall rear access panel. EXTENSION DUCT ,QVWDOODHOERZ FOR REAR EXHAUST: • Seal all joints with duct tape. It is importat to replace the ground clip after &XWDPPò´OHQJWKRIPPµGLDULJLG cutting the exhaust duct, (on rear exhaust model) • Reinstall rear access panel. GXFWDVVKRZQUHPRYHEXUUVIURPFXWHGJH 3ODFHFRYHUSODWHUHPRYHGIURPERWWRP • Attach this extension duct to blower housing. RIGU\HURYHUUHDUH[KDXVWRSHQLQJ • Seal all joints with duct tape. Reinstall near access panel. DRYER TOP VIEW Front of dryer 152 mm ALCOVE OR CLOSET INSTALLATION EXHAUST LENGTH CALCULATION • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. The installation PXVWFRQIRUPWRWKHIROORZLQJVSHFL¿FDWLRQV RIGID (Preferred) 3DUWVDUHDYDLODEOHIURP\RXUORFDOVHUYLFHRUJDQL]DWLRQ :;;µ;·'XFW :;;(OERZ :;;µ;·'XFW :;;$OXPLQXPKRRG WARNING: TO PREVENT LARGE AMOUNTS OF LINT AND MOISTURE FROM ACCUMULATING AND TO MAINTAIN DRYER EFFICIENCY, THIS MACHINE MUST BE EXHAUSTED OUTDOORS. • Minimum clearances between dryer cabinet and adjacent ZDOOVRURWKHUVXUIDFHVDUH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Use only for short run installations Recommended 4" DIA. 4" DIA. 4" No. of 90° Elbows 0 1 2 3 Rigid Metal 14 m (46 ft) 11 m (37 ft) 9 m (30 ft) 7 m (23 ft) 2-1/2" Rigid Metal 11 m (37 ft) 9 m (30 ft) 6.5 m (22 ft) 4.5 m (15 ft) Alcove Closet Sides 0” 1” Top 1” 1” Front µ Rear µ µ 0LQLPXP YHUWLFDO VSDFH IURP ÀRRU WR RYHUKHDG FDELQHWV FHLOLQJHWFLVLQ • Closet doors must be louvered or otherwise ventilated and must FRQWDLQDWOHDVWVTXDUHLQFKHVRIRSHQDUHDHTXDOO\GLVWULEXWHG,I the closet contains both a washer and a dryer, doors must contain at least 120 square inches of open area equally distributed. • )RUHYHU\H[WUDHOERZUHGXFHWKHDOORZDEOHYHQWV\VWHPOHQJWK by 10 ft. • 7ZRHOERZVZLOOEHWUHDWHGOLNHRQHHOERZ • )RUWKHVLGHH[KDXVWLQVWDOODWLRQVDGGRQHHOERZWRWKHFKDUW • The total vent system length includes all the straight portions and HOERZVRIWKHV\VWHPWUDQVLWLRQGXFWLQFOXGHG FLEXIBLE 7RWDO OHQJWK RI ÀH[LEOH PHWDO GXFW VKDOO QRW H[FHHG IW P 7KH IROORZLQJNLWLVDYDLODEOHIURP\RXORFDOVHUYLFHRUJDQL]DWLRQ NOTE: The clearances stated above are minimums. Consideration must be given to the type accessory kit XVHGZLWKGU\HU5HIHUWRWKHVSHFL¿FNLWLQVWUXFWLRQIRU details. .LW:;;µGLDÀH[LEOHPHWDOVHPLULJLG8/OLVWHGWUDQVLWLRQ GXFWLQFOXGHVHOERZV CONNECTING THE DRYER TO HOUSE VENT RIGID METAL TRANSITION DUCT • For best drying performance, a rigid metal transition duct is recommended. • Rigid metal transition ducts reduce the risk of crushing and kinking. UL-LISTED FLEXIBLE METAL (SEMI-RIGID) TRANSITION DUCT ,IULJLGPHWDOGXFWFDQQRWEHXVHGWKHQ8/OLVWHGÀH[LEOHPHW DOVHPLULJLGGXFWLQJFDQEHXVHG.LW:;; 1HYHU LQVWDOO ÀH[LEOH PHWDO GXFW LQ ZDOOV FHLOLQJV ÀRRUV RU other enclosed spaces. 7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW P • For many applications, installing elbows at both the dryer DQGWKHZDOOLVKLJKO\UHFRPPHQGHGVHHLOOXVWUDWLRQVEHORZ Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct, maximizing drying performance. • Avoid resting the duct on sharp objects. UL-LISTED FLEXIBLE METAL (FOIL-TYPE) TRANSITION DUCT • In special installations, it may be necessary to connect the GU\HUWRWKHKRXVHYHQWXVLQJDÀH[LEOHPHWDOIRLOW\SHGXFW $ 8/OLVWHG ÀH[LEOH PHWDO IRLOW\SH GXFW PD\ EH XVHG 21/< LQLQVWDOODWLRQVZKHUHULJLGPHWDORUÀH[LEOHPHWDOVHPLULJLG ducting cannot be used AND where a 4” diameter can be maintained throughout the entire length of the transition duct. ,Q&DQDGDDQGWKH8QLWHG6WDWHVRQO\WKHÀH[LEOHPHWDOIRLO W\SH GXFWV WKDW FRPSO\ ZLWK WKH ´2XWOLQH IRU &ORWKHV 'U\HU 7UDQVLWLRQ'XFW6XEMHFW$µVKDOOEHXVHG 1HYHU LQVWDOO ÀH[LEOH PHWDO GXFW LQ ZDOOV FHLOLQJV ÀRRUV RU other enclosed spaces. 7RWDOOHQJWKRIÀH[LEOHPHWDOGXFWVKRXOGQRWH[FHHGIHHW P • Avoid resting the duct on sharp objects. For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe. 2. Secure the duct with a clamp. :LWKWKHGU\HULQLWVSHUPDQHQWSRVLWLRQH[WHQGWKHGXFWWR its full length. Allow 2” of duct to overlap the exhaust pipe. &XWRȺDQGUHPRYHH[FHVVGXFW.HHSWKHGXFWDVVWUDLJKWDV SRVVLEOHIRUPD[LPXPDLUÀRZ 4. Secure the duct to the exhaust pipe with the other clamp. WHEN INSTALLED IN MANUFACTURED (MOBILE) HOMES NOTE TO INSTALLER - AFTER INSTALLATION CHECK Dryer must be exhausted to the outside. Exhaust MUST NOT be terminated beneath mobile home. Exhaust material MUST NOT support combustion. Installation MUST conform to Manufactured +RPH&RQVWUXFWLRQ6DIHW\6WDQGDUG7LWOH&)53DUW or when such standard is not applicable, the American National 6WDQGDUGRI0RELOH+RPHV$16,1)5$1R%)RUHOHFWULFDO connection, see “Connecting dryer using 4 wire connection”. THE FOLLOWING: (;+$867'8&70XVWPHHWVSHFVRQSDJH1RH[FHVVLYH WXUQV1RNLQNVRUREVWUXFWLRQVWRDLUÀRZ (;+$867+22'6KRXOGZRUNIUHHO\DQGRSHQGRZQZDUG *5281',1*'U\HUPXVWEHSURSHUO\JURXQGHGWRFRQIRUPWR local codes and ordinance requirements. 23(5$7,217XUQGU\HURQDQGFKHFNIRUKHDW +$1'&86720(57+(2:1(5·60$18$/*LYHLQVWUXFWLRQVRQ RSHUDWLQJWKHGU\HU$QVZHUDQ\TXHVWLRQV *,9(7+(6(,167$//$7,21,16758&7,216WRWKHFXVWRPHU USE OF CASTERS (120V PORTABLE MODELS ONLY) 4 For a portable installation screw casters into the holes on the bottom of the dryer. Refer to the “Installation Instructions for caster assembly” sheet to install casters.