globalproducts - CV Solutions, Inc.

advertisement
A
CL
S AND PANELS
GLOBALPRODUCTS
• C
AB
LE
AN
D
CO
N
DU
IT
TE
RE
CE
IN
RM
PT
ES
•
TI O N
STA
L
O
TR
N
CO
•
PLU
G
NS
SA
ND
IO
AT
•
INT
O
S
N
W
O
DW
RL
ID E
•
I N DU
ALLY SAFE SYST
EMS
STRIAL LIGHTING
RINSIC
E LE
One line. One planet.
SM
CT
R
I
C
AL
SO
LU
TI
S
THE
PEC
O
N E™ D I F F E R E N C E
Until now, if you needed hazardous area products to satisfy Zone or Division compliances in
North America and around the world, you had to deal with multiple manufacturers. No more.
Cooper Crouse-Hinds® introduces SpecOne, the only comprehensive line of hazardous area
electrical products meeting all worldwide explosion protection standards. Plus, it accommodates any conduit or cable wiring and termination method. The SpecOne line includes
hazardous area, non-metallic control stations and power distribution panels, HID and fluorescent industrial lighting, Zone-rated hubs and cable terminators, plugs, receptacles and
intrinsically safe systems.
If you want to make your life easier, just SpecOne.
S
PEC
O
NE GLOBAL PRODUCTS OFFERING
Products
*
Worldwide IEC/NEC/CEC
Zone 0
North American NEC/CEC
Zone 1
Zone 2
Division 1
Zone 1
Zone 2/ Division 2
Control Stations
GHG 43
GHG 43
EDS, EFS
N2SU,GHG 43
N2SU,GHG 43
Custom Control Panels
GHG 44
GHG 44
EJB
GHG 44
GHG 44
Fluorescent Lighting
eLLK
eLLK
EVF/EVFT
FVS, eLLK
FVS, eLLK
HID Low Wattage
EVLP
VMV
EVLP
EVLP
VMV, DMV
HID High Wattage
EVMA
VMV, FMV
EVMA
EVMA, FMV
FMV, VMV
EVA
V Series
EVA
EVA
V Series, Vaporgard®
Local Bus*
Incandescent
Intrinsically
Safe Remote I/O
Local Bus*
Local Bus*
Local Bus*
Local Bus*
Local Bus*
Intrinsically
Safe Remote I/O
FB**
FB**
FB**
FB**
FB**
FB**
Grounded
or Isolated
Grounded
or Isolated
Grounded
or Isolated
Grounded
or Isolated
Grounded
or Isolated
Grounded
or Isolated
IEC 309***
IEC 309***
Arktite®***
Arktite, IEC 309***
Arktite, IEC 309***
Brass
or Aluminum
Brass
or Aluminum
Myers Series
Krydon® NHUB
Myers Series
Krydon NHUB
Intrinsically
Safe Barriers
Plugs & Receptacles
Cable Glands
Polyamide
Polyamide,
Polyamide,
Brass
Brass or Aluminum Brass or Aluminum or Aluminum
Conduit Hubs
* Hardware can be installed in Zone 2/ Division 2
** Hardware can be installed in Zone 1/ Division 2
*** Interchangeable with ordinary location receptacles
Myers® Series
Myers Series
FEEDER
NON-HAZARDOUS AREA
EYS
HAZARDOUS AREA
CLASS I, ZONE 1
PRODUCT KEY*
1
3
5
7
9
eLLK or FVS Fluorescent Lighting Fixture
with TMC Terminator™ cable gland
2
4
eAZK Lighting Junction Box
with Zone 1 Myers® hubs
EVLP or EVMA HID Lighting Fixture
with TMC Terminator cable gland
GHG Switched IEC 309 Receptacle
with Zone 1 Myers hubs
GHG 273 Push-Button Control Station
with Zone 1 Myers hubs
6
GHG 44 Control Panel
with Zone 1 Myers hubs
8
EXKO Molded Plastic Distribution Panel
with Zone 1 Myers hubs
10
GHG 744 Terminal Box
with Zone 1 Myers hubs
N2RS Control Switch with TMC
Terminator cable gland
GHG 981 Socket Distribution Panel
with Zone 1 Myers hubs
CONTENTS
11
12
13
14
15
16
17
18
19
GHG Interlocked IEC 309 Receptacle
with Zone 1 Myers hubs
EXKO Molded Plastic Distribution Panel
with Zone 1 Myers hubs
* North American wiring practices allow the use of MC cable or rigid conduit for Zone 1 hazardous areas.
When entering a non-metallic enclosure, use a Zone 1 Myers hub.
If the installation requires MC cable, use TMC/TMCX Terminator connectors.
1
FSQC Arktite® Interlocked Receptacle
with TMCX Terminator cable gland
GHG 635 Manual Motor Starter
with Zone 1 Myers hubs
EBMS Magnetic Motor Starter
with TMCX Terminator cable gland
2
3
4
N2SU SpecOne™ Control Station
with Zone 1 Myers hubs
GHG 43 SpecOne Control Station
with Zone 1 Myers hubs
EDS Motor Starter with TMCX
Terminator cable gland
Product Key
5
Enclosure Entries
Control Stations
Panelboards
HID Lighting
Floodlights
Fluorescent Lighting
Terminal Boxes
Intrinsically Safe Products
Plugs and Receptacles
Zone 1 Rated Motor with TMC or
TMCX Terminator cable gland
1
ENCLOSURE ENTRIES
Crouse-Hinds/CEAG Zone 1 rated Myers® hubs and Terminator™ cable glands terminate any kind of cable
into most Ex enclosures.
A P P L I C AT I O N
ENTRY M ETH O D
Rigid steel or IMC conduit
Metal clad or tray cable
Zone 1 Myers Hubs
Terminator, Aluminum
or Brass Cable Glands
TECK cable
TECK Cable Glands
Steel wire armor, braided, lead Brass Cable Glands
sheath, unarmored cable
European unarmored cable
Polyamide Glands
Portable SO cord
CGB Cord & Cable Fittings
More Information
RATING S
EEx e Zone 1
Division 1, Zone 1
Division 2, Non-Hazardous
EEx d & EEx e protection
for Zone 1 areas.
EEx e & Ex i for Zone 1 areas
Division 2
Bulletin 4666-1198
CONTROL STATIONS
Crouse-Hinds/CEAG control stations have double entries and cover or base-mounted switches and contact
blocks for flexible wiring methods.
GHG 43 SERIES
N2SU SERIES
T E C H N I C A L DATA
IEC /NEC /C EC
NEC /C EC
Type of Protection
Third Party Certification
Switch Mounting
Entries
Degree of Protection
Control Options
AEx de IIC T6
EEx de IIC T6
UL, cUL, PTB
DIN-rail mounted contact blocks
Cable or conduit
NEMA 4X, IP 66
Push-buttons, selectors, pilot
lights, switches, potentiometers,
ammeters, terminals
AEx de IIC T6
Ex de IIC T6
UL, cUL
Cover-mounted contact blocks
Cable or conduit
NEMA 4X, IP 66
Push-buttons, selectors,
pilot lights
More Information
Bulletin 4667-0199
Bulletin 4667-0199
Instructional Video Available
PANELBOARDS
Crouse-Hinds/CEAG panelboards are available in non-metallic or aluminum enclosures.
2
MOLDED PLASTIC
SWITCHGEAR
P OW E R P L U S ™ S E R I E S
T E C H N I C A L DATA
IEC /NEC /C EC
NEC /C EC
Type of Protection
Third Party Certification
Enclosure Materials
Entries
Branch Breakers
Max. Main Circuit Breaker
Degree of Protection
Circuit Capability
AEx de IIC T4
EEx de IIC T4
UL, cUL, PTB
Fiberglass polyester
Cable or conduit
Encapsulated up to 40 Amps
180-Amp switch (fused)
IP 66
Expandable
Explosionproof
Class I, Division 1, 2, Zone 1, 2
UL, cUL
Aluminum
Cable or conduit
Bolt-on molded case up to 100 Amps
225 Amps
NEMA 3, 4, 7BCD, 9EFG, 12
PowerPlus Lighting: 18, 24 & 42
Power: 18 & 30
More Information
CEAG 6500 pg. 146
CH 5500 pg. IA-6
Bulletins 4633-0198, 4459-0595
HID LIGHTING
Z O N E 2 , D I V I S I O N 2 V M V S ER IES
Crouse-Hinds/CEAG Zone 2, Division 2, HID restricted-breathing fixtures are available with the instantrestrike option for fixtures meeting IEC standards.
TE CHN I CAL DATA
IEC/NEC/CEC
IEC
Type of Protection
AEx nR II T*
Ex nR II T*
UL, cUL, SIRA, PTB
North American
Yes
Cable or conduit
Ceiling, stanchion, wall, pendant
IP 66, Wet & Marine locations
NEMA 4, 4X
Ex nR II T*
PTB, SIRA, SAA
European
No
Cable or conduit
Ceiling, stanchion, wall, pendant
IP 66
CH 5500 pg. 3L-4
CH 6500 pg. 52-55
Third Party Certification
Ballast/Lamp Style
Instant Restrike
Entries
Mounting
Degree of Protection
More Information
Instructional Video Available
Z O N E 1 , D I V I S I O N 1 EV LP A ND EV M A
Crouse-Hinds/CEAG Zone 1, Division 1, HID fixtures are available with the instant-restrike option for
fixtures meeting IEC standards.
TE CHN I CAL DATA
IEC/NEC/CEC
IEC
Type of Protection
AEx de II B T*
Ex de II B T*
UL, cUL, PTB
North American
Yes
Cable or conduit
Ceiling, stanchion, wall, pendant
IP 66, Wet & Marine locations
NEMA 4, 4X
Ex de II B T*
CH 5500 pg. 4L-2
Bulletin 4617
CH 5500 pg. 4L-2
Bulletin 4617
Third Party Certification
Ballast/Lamp Style
Instant Restrike
Entries
Mounting
Degree of Protection
More Information
PTB
European
No
Cable or conduit
Ceiling, stanchion, wall, pendant
IP 66
Instructional Video Available
Z O N E 1 , Z O N E 2 HID FLO O D LIG H TS
Crouse-Hinds/CEAG Zone-rated floodlights are available with all lamp types ranging from 75 to 600 watts.
ZONE 2 - FMV SERIES
ZONE 1 - PX SERIES
T E CHN I CAL DATA
IEC/NEC/CEC
IEC
Type of Protection
AEx nR II T*
Ex nR II T*
UL, cUL, PTB
North American
Yes
Cable or conduit
Trunnion, pole
IP 54, Wet & Marine locations
NEMA 4, 4X
EEx de IIB T4
CH 5500 pg. 6L-7
CEAG 6500 pg. 50
Third Party Certification
Ballast/Lamp Style
Instant Restrike
Entries
Mounting
Degree of Protection
More Information
UL, cUL, PTB
European
No
Cable
Stirrup/trunnion
IP 67
Instructional Video Available
* Refer to conditions of certificate
3
FLUORESCENT LIGHTING
Z O NE 1 , FLU O R ES C ENT FIX TU R ES
Crouse-Hinds/CEAG fluorescent light fixtures are available in non-metallic or aluminum housings.
eLLK
FVS
T E C H N I C A L DATA
IEC /NEC /C EC
NEC /C EC
Type of Protection
Degree of Protection
AEx de IIC T4
EEx de IIC T4
UL, cUL, PTB
Yes
Bi-pin
Cable or conduit
Ceiling, pole, wall
Fiberglass polyester
housing with polycarbonate lens
IP 66
AEx de IIC T3
Ex de IIC T3
UL, cUL
No
Single ended
Cable or conduit
Ceiling, pole, wall
Aluminum housing with
polycarbonate lens
IP 54, Wet & Marine locations
More Information
CEAG 6500 pg. 30
CH 5500 pg. 5L-27
Third Party Certification
Emergency lighting option
Lamp Type
Entries
Mounting
Materials
Instructional Video Available
TERMINAL BOXES
Crouse-Hinds/CEAG terminal boxes are used for every application when connecting and terminating circuits.
4
GHG 744-749 SERIES
eAZK
T E C H N I C A L DATA
IEC /NEC /C EC
IEC /NEC /C EC
Type of Protection
AEx e II T6
EEx e II T6
Third Party Certification
Degree of Protection
Enclosure Materials
Application
Max. Circuit Capability
Entries
AEx e II T6
EEx e II T6
EEx ia IIC T6
UL, cUL, PTB
IP 66
Fiberglass polyester
Instrumentation and power
Expandable up to 296
Conduit or cable
UL, cUL, PTB
IP 66
Polyamide
Lighting
Up to 8
Conduit or cable
More Information
CEAG 6500 pg. 94
CEAG 6500 pg. 86
INTRINSICALLY SAFE PRODUCTS
I N T R I N S I C A L LY S A FE R EM O TE I/O
Crouse-Hinds/CEAG Intrinsically Safe I/O hardware can be mounted in hazardous areas saving over 40%
on material and installation costs.
LOCAL BUS SERIES
FB SERIES
TE CHN I CAL DATA
IEC/NEC/CEC
IEC /NEC /C EC
Type of Protection
EEx ia IIC
AEx ia IIC
PTB, FM, CSA
Division 2
MODBUS, Profibus DP,
FMS, Others
• All digital & analog inputs
& outputs, temperature
converters, trip points,
millivolt amplifier & load cells
EEx de/ia IIC
AEx de/ia IIC
PTB, UL
Zone 1, Division 2
MODBUS, Profibus DP,
FMS, Others
• All digital & analog inputs
& outputs, temperature
converters, trip points,
millivolt amplifier & load cells
Bulletin 1197/4/4.96
CEAG 6500 pg. 254
CEAG 6500 pg. 280
Third Party Certification
Remote I/O installed in
Communication Protocols
Protection
More Information
Instructional Video Available
I N T R I N S I C A L LY S A F E P R O D U C TS D IN-R A IL M O U NTED
Crouse-Hinds/CEAG offers the broadest range of intrinsically safe barriers for every application.
GROUNDED BARRIERS
I S O L AT E D B A R R I E R S
T E CHN I CAL DATA
IEC/NEC/CEC
IEC /NEC /C EC
Type of Protection
EEx ia IIC
AEx ia IIC
PTB, FM, CSA, UL
Division 2
• All digital & analog inputs
& outputs, temperature
converters, trip points,
millivolt amplifier & load cells,
other applications
EEx ia IIC
AEx ia IIC
PTB, FM
Division 2
• All digital & analog inputs
& outputs, temperature
converters, trip points,
millivolt amplifier & load cells
CEAG 6500 pg. 184
CEAG 6500 pg. 196
Third Party Certification
Installation Area
Protection
More Information
Instructional Video Available
PLUGS & RECEPTACLES
Crouse-Hinds/CEAG plugs and receptacles are universal. Arktite® connectors are a North American
standard; IEC 309 is the standard for the remainder of the world.
ARKTITE SERIES
IEC 309
TE CHN I CAL DATA
NEC/CEC
IEC /NEC /C EC
Amperages
Type of Protection
30, 60, 100, 200
Division 1
Division 2
UL, cUL, CSA
Yes
Yes
Toggle
Cable or conduit
Aluminum, non-metallic
NEMA 3R, 4X, 7BCD, 9FG, 12
16, 32, 63, 125
AEx de IIC T6
EEx de IIC T6
PTB, UL, cUL
Yes
Yes
Rotary
Cable or conduit
Fiberglass polyester
IP 66
Bulletin 4613-0698
CH 5500 section 2P, 4P
CEAG 6500 pg. 70
Third Party Certification
Interlocks Available
Overcurrent Protection
Switch
Entries
Materials
Degree of Protection
More Information
Instructional Video Available
5
Distributed by:
For more information:
If further assistance is required, please contact an authorized
Cooper Crouse-Hinds Distributor, Sales Office or Customer Service Department:
In the U.S.:
In Australia:
Cooper Crouse-Hinds
P.O. Box 4999
Syracuse, NY 13221
(315) 477-5531
FAX: (315) 477-5717
Crouse-Hinds (Australia) Pty. Ltd.
61-29-743-7000
FAX: 61-29-743-7069
sales@crouse-hinds.com.au
In Canada:
Cooper Crouse-Hinds Canada
(905) 507-4187
FAX: (905) 501-4078
CEAG Crouse-Hinds Asia Pacific Pte. Ltd.
65-297-4849
FAX: 65-297-4819
sales@cchspore.com.sg
In Mexico:
In India:
In Asia (Singapore):
Crouse-Hinds Domex, S.A. de C.V.
(525) 628-1900
FAX: (525) 628-1999
CEAG Flameproof Control Gears Private Ltd.
91-22-492-6355
FAX: 91-22-495-0486
In Latin America/Caribbean:
For the latest in new products and
services, visit our web site at:
Cooper Crouse-Hinds
(315) 477-5787 (USA)
FAX: (315) 477-5118
http://www.crouse-hinds.com
In Europe (Germany):
CEAG Sicherheitstechnik GmbH
49-2921-69751
FAX: 49-2921-69604
Solutions.Worldwide.
TM
4675-0499
Crouse-Hinds is a registered trademark of Cooper Industries, Inc.
© 1999 Cooper Industries, Inc.
Printed in U.S.A.
Download