A CL S AND PANELS GLOBALPRODUCTS • C AB LE AN D CO N DU IT TE RE CE IN RM PT ES • TI O N STA L O TR N CO • PLU G NS SA ND IO AT • INT O S N W O DW RL ID E • I N DU ALLY SAFE SYST EMS STRIAL LIGHTING RINSIC E LE One line. One planet. SM CT R I C AL SO LU TI S THE PEC O N E™ D I F F E R E N C E Until now, if you needed hazardous area products to satisfy Zone or Division compliances in North America and around the world, you had to deal with multiple manufacturers. No more. Cooper Crouse-Hinds® introduces SpecOne, the only comprehensive line of hazardous area electrical products meeting all worldwide explosion protection standards. Plus, it accommodates any conduit or cable wiring and termination method. The SpecOne line includes hazardous area, non-metallic control stations and power distribution panels, HID and fluorescent industrial lighting, Zone-rated hubs and cable terminators, plugs, receptacles and intrinsically safe systems. If you want to make your life easier, just SpecOne. S PEC O NE GLOBAL PRODUCTS OFFERING Products * Worldwide IEC/NEC/CEC Zone 0 North American NEC/CEC Zone 1 Zone 2 Division 1 Zone 1 Zone 2/ Division 2 Control Stations GHG 43 GHG 43 EDS, EFS N2SU,GHG 43 N2SU,GHG 43 Custom Control Panels GHG 44 GHG 44 EJB GHG 44 GHG 44 Fluorescent Lighting eLLK eLLK EVF/EVFT FVS, eLLK FVS, eLLK HID Low Wattage EVLP VMV EVLP EVLP VMV, DMV HID High Wattage EVMA VMV, FMV EVMA EVMA, FMV FMV, VMV EVA V Series EVA EVA V Series, Vaporgard® Local Bus* Incandescent Intrinsically Safe Remote I/O Local Bus* Local Bus* Local Bus* Local Bus* Local Bus* Intrinsically Safe Remote I/O FB** FB** FB** FB** FB** FB** Grounded or Isolated Grounded or Isolated Grounded or Isolated Grounded or Isolated Grounded or Isolated Grounded or Isolated IEC 309*** IEC 309*** Arktite®*** Arktite, IEC 309*** Arktite, IEC 309*** Brass or Aluminum Brass or Aluminum Myers Series Krydon® NHUB Myers Series Krydon NHUB Intrinsically Safe Barriers Plugs & Receptacles Cable Glands Polyamide Polyamide, Polyamide, Brass Brass or Aluminum Brass or Aluminum or Aluminum Conduit Hubs * Hardware can be installed in Zone 2/ Division 2 ** Hardware can be installed in Zone 1/ Division 2 *** Interchangeable with ordinary location receptacles Myers® Series Myers Series FEEDER NON-HAZARDOUS AREA EYS HAZARDOUS AREA CLASS I, ZONE 1 PRODUCT KEY* 1 3 5 7 9 eLLK or FVS Fluorescent Lighting Fixture with TMC Terminator™ cable gland 2 4 eAZK Lighting Junction Box with Zone 1 Myers® hubs EVLP or EVMA HID Lighting Fixture with TMC Terminator cable gland GHG Switched IEC 309 Receptacle with Zone 1 Myers hubs GHG 273 Push-Button Control Station with Zone 1 Myers hubs 6 GHG 44 Control Panel with Zone 1 Myers hubs 8 EXKO Molded Plastic Distribution Panel with Zone 1 Myers hubs 10 GHG 744 Terminal Box with Zone 1 Myers hubs N2RS Control Switch with TMC Terminator cable gland GHG 981 Socket Distribution Panel with Zone 1 Myers hubs CONTENTS 11 12 13 14 15 16 17 18 19 GHG Interlocked IEC 309 Receptacle with Zone 1 Myers hubs EXKO Molded Plastic Distribution Panel with Zone 1 Myers hubs * North American wiring practices allow the use of MC cable or rigid conduit for Zone 1 hazardous areas. When entering a non-metallic enclosure, use a Zone 1 Myers hub. If the installation requires MC cable, use TMC/TMCX Terminator connectors. 1 FSQC Arktite® Interlocked Receptacle with TMCX Terminator cable gland GHG 635 Manual Motor Starter with Zone 1 Myers hubs EBMS Magnetic Motor Starter with TMCX Terminator cable gland 2 3 4 N2SU SpecOne™ Control Station with Zone 1 Myers hubs GHG 43 SpecOne Control Station with Zone 1 Myers hubs EDS Motor Starter with TMCX Terminator cable gland Product Key 5 Enclosure Entries Control Stations Panelboards HID Lighting Floodlights Fluorescent Lighting Terminal Boxes Intrinsically Safe Products Plugs and Receptacles Zone 1 Rated Motor with TMC or TMCX Terminator cable gland 1 ENCLOSURE ENTRIES Crouse-Hinds/CEAG Zone 1 rated Myers® hubs and Terminator™ cable glands terminate any kind of cable into most Ex enclosures. A P P L I C AT I O N ENTRY M ETH O D Rigid steel or IMC conduit Metal clad or tray cable Zone 1 Myers Hubs Terminator, Aluminum or Brass Cable Glands TECK cable TECK Cable Glands Steel wire armor, braided, lead Brass Cable Glands sheath, unarmored cable European unarmored cable Polyamide Glands Portable SO cord CGB Cord & Cable Fittings More Information RATING S EEx e Zone 1 Division 1, Zone 1 Division 2, Non-Hazardous EEx d & EEx e protection for Zone 1 areas. EEx e & Ex i for Zone 1 areas Division 2 Bulletin 4666-1198 CONTROL STATIONS Crouse-Hinds/CEAG control stations have double entries and cover or base-mounted switches and contact blocks for flexible wiring methods. GHG 43 SERIES N2SU SERIES T E C H N I C A L DATA IEC /NEC /C EC NEC /C EC Type of Protection Third Party Certification Switch Mounting Entries Degree of Protection Control Options AEx de IIC T6 EEx de IIC T6 UL, cUL, PTB DIN-rail mounted contact blocks Cable or conduit NEMA 4X, IP 66 Push-buttons, selectors, pilot lights, switches, potentiometers, ammeters, terminals AEx de IIC T6 Ex de IIC T6 UL, cUL Cover-mounted contact blocks Cable or conduit NEMA 4X, IP 66 Push-buttons, selectors, pilot lights More Information Bulletin 4667-0199 Bulletin 4667-0199 Instructional Video Available PANELBOARDS Crouse-Hinds/CEAG panelboards are available in non-metallic or aluminum enclosures. 2 MOLDED PLASTIC SWITCHGEAR P OW E R P L U S ™ S E R I E S T E C H N I C A L DATA IEC /NEC /C EC NEC /C EC Type of Protection Third Party Certification Enclosure Materials Entries Branch Breakers Max. Main Circuit Breaker Degree of Protection Circuit Capability AEx de IIC T4 EEx de IIC T4 UL, cUL, PTB Fiberglass polyester Cable or conduit Encapsulated up to 40 Amps 180-Amp switch (fused) IP 66 Expandable Explosionproof Class I, Division 1, 2, Zone 1, 2 UL, cUL Aluminum Cable or conduit Bolt-on molded case up to 100 Amps 225 Amps NEMA 3, 4, 7BCD, 9EFG, 12 PowerPlus Lighting: 18, 24 & 42 Power: 18 & 30 More Information CEAG 6500 pg. 146 CH 5500 pg. IA-6 Bulletins 4633-0198, 4459-0595 HID LIGHTING Z O N E 2 , D I V I S I O N 2 V M V S ER IES Crouse-Hinds/CEAG Zone 2, Division 2, HID restricted-breathing fixtures are available with the instantrestrike option for fixtures meeting IEC standards. TE CHN I CAL DATA IEC/NEC/CEC IEC Type of Protection AEx nR II T* Ex nR II T* UL, cUL, SIRA, PTB North American Yes Cable or conduit Ceiling, stanchion, wall, pendant IP 66, Wet & Marine locations NEMA 4, 4X Ex nR II T* PTB, SIRA, SAA European No Cable or conduit Ceiling, stanchion, wall, pendant IP 66 CH 5500 pg. 3L-4 CH 6500 pg. 52-55 Third Party Certification Ballast/Lamp Style Instant Restrike Entries Mounting Degree of Protection More Information Instructional Video Available Z O N E 1 , D I V I S I O N 1 EV LP A ND EV M A Crouse-Hinds/CEAG Zone 1, Division 1, HID fixtures are available with the instant-restrike option for fixtures meeting IEC standards. TE CHN I CAL DATA IEC/NEC/CEC IEC Type of Protection AEx de II B T* Ex de II B T* UL, cUL, PTB North American Yes Cable or conduit Ceiling, stanchion, wall, pendant IP 66, Wet & Marine locations NEMA 4, 4X Ex de II B T* CH 5500 pg. 4L-2 Bulletin 4617 CH 5500 pg. 4L-2 Bulletin 4617 Third Party Certification Ballast/Lamp Style Instant Restrike Entries Mounting Degree of Protection More Information PTB European No Cable or conduit Ceiling, stanchion, wall, pendant IP 66 Instructional Video Available Z O N E 1 , Z O N E 2 HID FLO O D LIG H TS Crouse-Hinds/CEAG Zone-rated floodlights are available with all lamp types ranging from 75 to 600 watts. ZONE 2 - FMV SERIES ZONE 1 - PX SERIES T E CHN I CAL DATA IEC/NEC/CEC IEC Type of Protection AEx nR II T* Ex nR II T* UL, cUL, PTB North American Yes Cable or conduit Trunnion, pole IP 54, Wet & Marine locations NEMA 4, 4X EEx de IIB T4 CH 5500 pg. 6L-7 CEAG 6500 pg. 50 Third Party Certification Ballast/Lamp Style Instant Restrike Entries Mounting Degree of Protection More Information UL, cUL, PTB European No Cable Stirrup/trunnion IP 67 Instructional Video Available * Refer to conditions of certificate 3 FLUORESCENT LIGHTING Z O NE 1 , FLU O R ES C ENT FIX TU R ES Crouse-Hinds/CEAG fluorescent light fixtures are available in non-metallic or aluminum housings. eLLK FVS T E C H N I C A L DATA IEC /NEC /C EC NEC /C EC Type of Protection Degree of Protection AEx de IIC T4 EEx de IIC T4 UL, cUL, PTB Yes Bi-pin Cable or conduit Ceiling, pole, wall Fiberglass polyester housing with polycarbonate lens IP 66 AEx de IIC T3 Ex de IIC T3 UL, cUL No Single ended Cable or conduit Ceiling, pole, wall Aluminum housing with polycarbonate lens IP 54, Wet & Marine locations More Information CEAG 6500 pg. 30 CH 5500 pg. 5L-27 Third Party Certification Emergency lighting option Lamp Type Entries Mounting Materials Instructional Video Available TERMINAL BOXES Crouse-Hinds/CEAG terminal boxes are used for every application when connecting and terminating circuits. 4 GHG 744-749 SERIES eAZK T E C H N I C A L DATA IEC /NEC /C EC IEC /NEC /C EC Type of Protection AEx e II T6 EEx e II T6 Third Party Certification Degree of Protection Enclosure Materials Application Max. Circuit Capability Entries AEx e II T6 EEx e II T6 EEx ia IIC T6 UL, cUL, PTB IP 66 Fiberglass polyester Instrumentation and power Expandable up to 296 Conduit or cable UL, cUL, PTB IP 66 Polyamide Lighting Up to 8 Conduit or cable More Information CEAG 6500 pg. 94 CEAG 6500 pg. 86 INTRINSICALLY SAFE PRODUCTS I N T R I N S I C A L LY S A FE R EM O TE I/O Crouse-Hinds/CEAG Intrinsically Safe I/O hardware can be mounted in hazardous areas saving over 40% on material and installation costs. LOCAL BUS SERIES FB SERIES TE CHN I CAL DATA IEC/NEC/CEC IEC /NEC /C EC Type of Protection EEx ia IIC AEx ia IIC PTB, FM, CSA Division 2 MODBUS, Profibus DP, FMS, Others • All digital & analog inputs & outputs, temperature converters, trip points, millivolt amplifier & load cells EEx de/ia IIC AEx de/ia IIC PTB, UL Zone 1, Division 2 MODBUS, Profibus DP, FMS, Others • All digital & analog inputs & outputs, temperature converters, trip points, millivolt amplifier & load cells Bulletin 1197/4/4.96 CEAG 6500 pg. 254 CEAG 6500 pg. 280 Third Party Certification Remote I/O installed in Communication Protocols Protection More Information Instructional Video Available I N T R I N S I C A L LY S A F E P R O D U C TS D IN-R A IL M O U NTED Crouse-Hinds/CEAG offers the broadest range of intrinsically safe barriers for every application. GROUNDED BARRIERS I S O L AT E D B A R R I E R S T E CHN I CAL DATA IEC/NEC/CEC IEC /NEC /C EC Type of Protection EEx ia IIC AEx ia IIC PTB, FM, CSA, UL Division 2 • All digital & analog inputs & outputs, temperature converters, trip points, millivolt amplifier & load cells, other applications EEx ia IIC AEx ia IIC PTB, FM Division 2 • All digital & analog inputs & outputs, temperature converters, trip points, millivolt amplifier & load cells CEAG 6500 pg. 184 CEAG 6500 pg. 196 Third Party Certification Installation Area Protection More Information Instructional Video Available PLUGS & RECEPTACLES Crouse-Hinds/CEAG plugs and receptacles are universal. Arktite® connectors are a North American standard; IEC 309 is the standard for the remainder of the world. ARKTITE SERIES IEC 309 TE CHN I CAL DATA NEC/CEC IEC /NEC /C EC Amperages Type of Protection 30, 60, 100, 200 Division 1 Division 2 UL, cUL, CSA Yes Yes Toggle Cable or conduit Aluminum, non-metallic NEMA 3R, 4X, 7BCD, 9FG, 12 16, 32, 63, 125 AEx de IIC T6 EEx de IIC T6 PTB, UL, cUL Yes Yes Rotary Cable or conduit Fiberglass polyester IP 66 Bulletin 4613-0698 CH 5500 section 2P, 4P CEAG 6500 pg. 70 Third Party Certification Interlocks Available Overcurrent Protection Switch Entries Materials Degree of Protection More Information Instructional Video Available 5 Distributed by: For more information: If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor, Sales Office or Customer Service Department: In the U.S.: In Australia: Cooper Crouse-Hinds P.O. Box 4999 Syracuse, NY 13221 (315) 477-5531 FAX: (315) 477-5717 Crouse-Hinds (Australia) Pty. Ltd. 61-29-743-7000 FAX: 61-29-743-7069 sales@crouse-hinds.com.au In Canada: Cooper Crouse-Hinds Canada (905) 507-4187 FAX: (905) 501-4078 CEAG Crouse-Hinds Asia Pacific Pte. Ltd. 65-297-4849 FAX: 65-297-4819 sales@cchspore.com.sg In Mexico: In India: In Asia (Singapore): Crouse-Hinds Domex, S.A. de C.V. (525) 628-1900 FAX: (525) 628-1999 CEAG Flameproof Control Gears Private Ltd. 91-22-492-6355 FAX: 91-22-495-0486 In Latin America/Caribbean: For the latest in new products and services, visit our web site at: Cooper Crouse-Hinds (315) 477-5787 (USA) FAX: (315) 477-5118 http://www.crouse-hinds.com In Europe (Germany): CEAG Sicherheitstechnik GmbH 49-2921-69751 FAX: 49-2921-69604 Solutions.Worldwide. TM 4675-0499 Crouse-Hinds is a registered trademark of Cooper Industries, Inc. © 1999 Cooper Industries, Inc. Printed in U.S.A.