T900 SERIES INPUT VOLTAGE: 120 or 208-277VAC, 60 Hz, varies by model. TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG. APPLICATIONS TYPE VOLTAGE CONTACT RATING General Purpose 120/277VAC 20A Motor 120VAC 240VAC 1HP 2HP OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C). CALIFORNIA Title 24 ASHRAE 90.1 Parking lot lighting HVAC Display lighting Security lighting Lighted signage Storefront lighting CONTACT RATINGS SPECIFICATIONS PHOTOELECTRIC & 7 DAY CONTROL COMBO DIFFERENT SCHEDULES EACH DAY RESERVE POWER STANDARD 2 & 3 CIRCUIT LIGHTING CONTROL CENTERS POWER CONSUMPTION: 5 watts maximum. ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp. Other enclosures include cover for access to by-pass switches with suffix "E" or Indoor/Outdoor NEMA 3 metal with suffix "O" (see page 153 for enclosure dimensions). Optional "E" cover Model 2101 supplied with unit. WIRING DIAGRAMS T930L T930L T920L T920L ONLYCIRCUITS CIRCUITS1 1AND AND2 2ARE AREINCLUDED INCLUDEDININT920L T920L ONLY ORDERING INFO FEATURES CATALOG NO. SCHEDULING: CIRCUIT 1: ON automatically at dusk, OFF at individual preset times each day, including skipping days when desired. Unit can be set to turn ON before dawn for early morning lighting. CIRCUIT 2: ON at dusk, OFF at dawn automatically, daily. CIRCUIT 3: Individual daily ON and OFF settings at desired times, including skipping any desired day or days Minimum ON is setting 1 hour with a minimum OFF setting of 2 hours. Minimum 8 hours between 2 OFF settings. 7 day calendar dial will accommodate up to 2 pairs of ON-OFF trippers per day – 7 pairs are supplied. SKIP-A-DAY: Omit operations on any day. UPC CODE INPUT SUPPLY (VAC) 60Hz 41033 120 2 SPDT T920L-E 41034 120 2 SPDT T920L-O 41035 120 2 SPDT T930L 41055 120 3 SPDT T930L-E 41056 120 3 SPDT T930L-O 41057 120 3 SPDT Metal Indoor NEMA 1 Metal Indoor NEMA 1 with switch access Metal Indoor/outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 with switch access Metal Indoor/outdoor NEMA 3 ON ON OFF OFF ON ON OFF OFF AUTO AUTO AUTO AUTO SWITCH TIMETIME SWITCH OFF OFF ON ON MM C C NOTE: NOTE: Contacts 7-12 Contacts 7-12 unpowered. areare unpowered. RELAY RELAY PHOTOELECTRIC PHOTOELECTRIC CONTROL CONTROL ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF AUTO AUTO AUTO AUTO AUTO AUTO NOTE: NOTE: Contacts 4-12 Contacts 4-12 unpowered. areare unpowered. RELAY RELAY C C PHOTOELECTRIC PHOTOELECTRIC CONTROL CONTROL MM CONTACTOR CONTACTOR CONTROL CONTROL CIRCUIT LINELINE CIRCUIT RED RED WHITE WHITE BLACK BLACK L1 L1 OPEN CLOSEOPEN LINELINE CLOSE 1 1 CONTACTOR CONTACTOR CONTROL CONTROL CIRCUIT CIRCUIT 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 H 120V H 120V N N 60C 60C LINELINE TIME TIME SWITCH SWITCH TO DAWN SAFETY LIGHTS DUSKDUSK TO DAWN SAFETY LIGHTS (PHOTOCELL - PHOTOCELL (PHOTOCELL ON - ON PHOTOCELL OFF) OFF) NEU.NEU. OPEN OPEN CLOSE CLOSE H 120V H 120V N N 60C BLACK 60C BLACK LINELINE WHITE WHITE RED RED 2 2 L1 L1 LINELINE OPEN OPEN OPENLINELINE OPEN CLOSE CLOSE CLOSE CLOSE 3 3 1 1 TO DAWN SAFETY LIGHTS DUSKDUSK TO DAWN SAFETY LIGHTS (PHOTOCELL - PHOTOCELL (PHOTOCELL ON - ON PHOTOCELL OFF) OFF) 2 2 NEUNEU OPEN OPEN CLOSE CLOSE LOAD LOAD LOAD LOAD #P69 for 7 pairs of ON/OFF trippers. #36 (120V) #66061 RESERVE POWER: Standard feature on all models keep dial on time up to 24 hours during power outage. NOTE: All models are designed to control a contactor circuit and are not recommended for direct switching of most lighting loads. TORK 45 ENCLOSURE TYPE OUTPUT CONTACTS MANUAL BY-PASS SWITCHES: Single pole, 20 Amps – one per circuit. Factory pre-wired to terminal strip. ON/OFF/AUTO positions for each circuit is independent – will not disturb automatic settings. ELECTROMECHANICAL CONTROLS MANUAL CONTROLS MANUAL CONTROLS MANUAL CONTROLS MANUAL CONTROLS T920L Replacement Trippers Replacement Motor Replacement Bypass Switch ALL3 3CIRCUITS CIRCUITSARE AREINCLUDED INCLUDEDININT930L T930L ALL A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com SPECIFICATION WRITER’S GUIDE T900 SERIES – Furnish and install, where shown, a TORK Photo/Time Control of the 7 Day Calendar dial type, which shall be suitable to operate mechanicallyheld contactor(s). Photo/Time Control shall be pre-wired to a central terminal block which provides connecting terminals for Photocontrol and independent contactor control circuit(s). Time switch shall function to prevent energization of lighting for preset periods each day. Time switch dial shall permit different ON/OFF settings for each day of the week, with provision for omitting selected days. Control shall include pre-wired manual switching for each contactor circuit specified. Enclosure shall be NEMA 1 surface. Photocontrol to be remotely installed in appropriate outside location. It shall be fully temperature compensated and shall provide for time delay of at least 15 seconds to prevent false switching. Photocontrol shall operate control center to energize whenever natural lighting falls below 1.5 - 5.5 foot candles turn on. Spring driven reserve timing motor shall be provided sufficient to operate time switch controls at least 24 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve power unit. FOR DUSK-TO-DAWN LIGHTS: Control shall provide additional contactor circuit to above specifications except that it shall be responsive to Photocontrol only. Tork Model T-920L or equal. FOR PRESET ON/PRESET OFF: Control shall provide for additional contactor circuit to above specification except that it shall be responsive to time switch only. Tork Model T-930L. TORK 46