Prices as of April 27, 2016. Check Web site for most current prices. Dold UG6960 Series Dual Channel Emergency Stop with Adjustable Delay Designed to protect people and machines in applications with E-stop buttons and safety gates. • Various delay functions adjustable at device (power off before selecting the desired function): - Release delay - Release delay retriggerable - On delay - Fleeting on make / break - Delay function settable via potentiometer • According to: - Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008 - SIL Claimed Level (SIL CL) 3 to IEC/EN 62061 - Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511 - Acc. to EN 50156-1 for furnaces • Line fault detection at the ON pushbutton: • Manual restart or automatic restart • With cross fault monitoring • 2-channel • Forcibly guided output contacts • Output: 2 N.O. instantaneous contact and 2 N.O. delayed contacts • 1 semiconductor monitoring output for instantaneous contacts, 1 semiconductor monitoring output for delayed contacts • LED indicator for operation, safety function, time delay and failure • Width: 22.5 mm Note: See Delay Functions for more information. Safety Data – Values per EN ISO 13849-1 Category Performance level MTTFd 4 PLe DCavg 99% >100 years Safety Data – Values per IEC/EN 62061 / IEC/EN 61508 SIL CL SIL HFT (Hardware Failure Tolerance) DCavg SFF PFHD 3 3 1 Safety Relays Selection Chart 99% 99.7% Part Number 3.59E-10 h -1 Price Marking Type UG6960-04PS100-300 $235.00 Function Diagram S12 A1+ A2 t<tOn t>tOn 24VDC overvoltage and short circuit protection monitoring logic instantaneous contact K1 delayed contact 47 57 K3 + K1/K2 ON K1/K2 K2 K3 K3/K4 K4 K2 + K3/K4 K4 t>tdiff t<tdiff GND tv 13 23 RES S11 S21 S12 S22 ST1ST2 K1 S22 13/14 23/24 38 47/48 57/58 68 Safety relay module 2 N.O. instantaneous positive guided safety contact(s), 2 N.O. time delay (selectable) positive guided safety contact(s), 1 N.O. instantaneous monitoring contact, 1 N.O. time delay monitoring contact Block Diagram A1/A2 ST1 Voltage Outputs 14 24 38 48 58 68 tv tdiff: max. time delay for simultaneity demand dependent on selected safety function E-Stop, safety gate, safety mat tdiff: max. 3s Light curtains tdiff: max. 1s Two-hand control tdiff: max. 0,5s other times on request tOn: max. actuation time of start button Standard tOn: max. 3s other times on request tv: Time delay Example: release delay Book 3 (14.3) eSA-144 Safety Electrical Components 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices. Dold UG6960 Series Dual Channel Emergency Stop with Adjustable Delay Company Information Terminal Blocks Power Distribution Blocks Dold UG6960 Series Dual Channel Emergency Stop with Adjustable Delay Specification Table General Specifications Temperature Altitude Vibration Resistance Degree of Protection Housing Weight Terminal Designation per EN 50 005 Wire Connections Wire Fixing Wire Connection Wiring Accessories Storage: -25°C to 85°C (-13°F to 185°F) Operating: -15°C to 55°C (5°F to 131°F) <2.000 meters ZIPLink Connection System Amplitude: 0.35mm, Frequency: 10 to 55 Hz (IEC/EN 60-068-2-6) Per IEC/EN 60 529. Housing: IP40; Terminals IP20 Multi-wire Connectors UL 94V-0 Thermoplastic 250g (8.82 oz.) 1x4 mm2 solid or 1 x 2.5 mm2 stranded ferruled (isolated) or 2 x 1.5 mm2 stranded ferruled (isolated) DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 solid DIN 46 228-1/-2/-3/-4 Terminal screws M3.5 box terminals with wire protection. M12 Junction Blocks 60degC/75degC Copper conductors only; AWG20-12 Sol/Str Torque 0.5NM Input Specifications Nominal Voltage Voltage Range Maximum Consumption Nominal Frequency Minimum Off-time Panel Interface Connectors 24VDC At 10% residual ripple: AC/DC: 0.9 to 1.1 UN; AC: 0.85 to 1.1 UN Wiring Duct DC approx. 3.2 W Cable Ties Not applicable 250 ms Control Voltage on S11 At UN Control Current Typ. Over S12, S22 Min. Voltage on S12, S22 (relay activated) Short Circuit Protection Overvoltage Protection Wire 22VDC Bulk Multi-conductor Cables 8mA at UN 20VDC Wire Management Products Internal with PTC (Positive Temperature Coefficient resistor) Internal VDR (Voltage Dependent Resistor) Output Specifications Electrical Contact Life Mechanical Life Contact Type Operate Delay Release Delay Nominal Output Voltage Thermal Current (Ith) Short Circuit Strength Switching Capacity (IEC/EN 60 947-5-1) Switching Frequency Agency Approvals and Standards Power Supplies AC 15 at 5A, 230VAC: > 1.5x105 switching cycles DC Converters > 10x106 switching cycles 2 N.O. instantaneous contacts 2 N.O. delayed contacts(N.O. contacts are safety contacts) Manual start: 30 ms; automatic start: 350 ms. E-Stop (1) (6), Safety gate (2) (7), Exclusive or contacts (5): Start up at U : < 65 ms Release delay at U and disconnecting the supply: < 40 ms Release delay at U and disconnecting S12,S22: < 60 ms Transformers and Filters Circuit Protection Tools 24VDC: See continuous current limit curve in installation manual. Test Equipment Max. 8A. See continuous current limit curve in installation manual. Enclosures Max. fuse rating: 6A gL (IEC/EN 60 947-5-1); Line circuit breaker: B 6A Enclosure Climate Control AC 15: N.O. contacts: 3A/230V DC 13: N.O. contacts: 2A/DC24V. Safety: Electrical Components instantaneous: Max. 1800 switching cycles/hr delayed: Max. 360 switching cycles/hr CSA, cULus file E107778, CE, RoHS, TUV Safety: Protective Wear To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number’s web page at www.automationdirect.com Release Delay: When disconnecting the signal the contacts remain closed and only open after the time is finished. Restarting the unit during time delay has no influence. The time has to run down fully before you can restart the unit. Release Delay Retriggerable: Same as above, but you can restart the unit while the time is running and before the contacts open. On Delay: The output contacts are energized after the adjusted time after restarting the unit. Fleeting on Make: The output contacts are energized after restarting the unit for the adjusted time, and then go off again. Fleeting on Break: The output contacts are energized for the adjusted time after disconnecting the signal, and then go off again. Book 3 (14.3) www.automationdirect.com/safety Sensor Cables and Connectors Safety Electrical Components eSA-145 Terms and Conditions Prices as of April 27, 2016. Check Web site for most current prices. Dold UG6960 Series Dual Channel Emergency Stop with Adjustable Delay Connection Terminals Dimensions mm(in) Characteristic Curves I2 (A2) 2 256A 250 225 I(mA) 200 175 50 150 40 125 30 100 20 75 10 50 25 0 0 10 20 30 40 50 device free-standing max. current at 55°C over 4 contact path = 5A ^= 4x52A2 = 100A2 device mounted without distance heated by devices with same load, max. current at 55°C over 4 contact path = 1A ^= 4x12A2 = 4A2 60 T (°C) 10 20 30 40 ∑ I = I 38 + I 68 z.B. : ∑ I = 35mA + 15mA = 50mA I3 8 - current semiconductor output 38 I6 8 - current semiconductor output 68 50 60 T (°C) Quadratic total current limit curve semiconductor monitoring outputs I2 = I21 + I22 + I23 + I24 I1, I2 , I3 - current in contact paths Quadratic total current limit curve output contacts Book 3 (14.3) eSA-146 Safety Electrical Components 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices. Dold UG6960 Series Dual Channel Emergency Stop with Adjustable Delay Company Information Terminal Blocks Power Distribution Blocks Application Examples DC24V Wiring Accessories On DC24V On ZIPLink Connection System K5 Multi-wire Connectors K6 K5 K7 K6 Safety function Safetyfunction Sensor Cables and Connectors K8 Reset Reset A1+ A1+ ST1 ST1 ST2 S22 S11 S11 S21S21 S22 S12 S12 K1 UG6961 RES RES ST2 UG6960 K2 17 13 27 A2 A2 18 K5 28 14K6 K5 0V 47 + K1 K2 K1 K2 23 M12 Junction Blocks + K3 K1 K2 K3 K4 K4 38 24 57 + 48 38 K6 K7 58 Panel Interface Connectors 68 Wiring Duct K8 Cable Ties 0V Wire Safety function: see below, Manual-Start (for automatic start make a bridge to ST2 instead of ON button). Safety function: see below, Manual-Start (for automatic start make a bridge to ST2 instead of ON button). Delay function: release delay (1) Delay function: release delay (1) K1/K2 instantaneous contact, K3/K4 delayed contact Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters S21 S22 S11 S21 S12 S22 S11 S12 Transformers and Filters Fct.: E-stop (1), with cross fault detection 3, PL e, Cat. 4 Fct.: Safety gate (2), with cross fault detection SIL 3, PL e, Cat. 4 Circuit Protection Tools (+) Test Equipment + Enclosure Climate Control Safety: Electrical Components - Safety: Protective Wear coded actuator K4 coded switch + Enclosures - - - On - coded actuator coded switch + Terms and Conditions + - K5 A1(+) S21 ST1 S22 S11 S12 13 23 ... ... 14 24 ... ... BG5920 UG6960, UG6961, S2: auf Handstart UG6970*, UG6980 RES A2(-) K4 K5 (-) *UG6970: The safety function 2 is connected as well as safety function 1, but S11 = S31, S12 = S32, S21 = S41, S22 = S42 and ST1 = ST2 Book 3 (14.3) www.automationdirect.com/safety Safety Electrical Components eSA-147 Prices as of April 27, 2016. Check Web site for most current prices. Dold LG5929 Extension Module Additional contacts for emergency-stop modules and safety gate monitors. • 1-channel or 2-channel connection • LED indication for operation • Output: 5 N.O. and 1 N.C. contacts Safety Data – Values per EN ISO 13849-1 Category Performance level MTTFd 4 according to EN 954-1 PLe according to EN 13849-1 DCavg 99% >100 years Safety Data – Values per IEC/EN 62061 /IEC/EN 61508 SIL CL SIL HFT (Hardware Failure Tolerance) DCavg Safety Relays Selection Chart Part Number LG5929-60-100-61 Price Marking Type Voltage Outputs $95.00 Safety relay extension module 24 VAC/VDC 5 N.O./1 N.C. SFF PFHD 3 per IEC/EN 62061 3 per IEC/EN 61508 1 99% 99.7% 4.68E-10 h-1 Safety Relay Extenson Module Specification Table General Specifications Temperature Altitude Vibration Resistance Degree of Protection Housing Weight Agency Approvals and Standards Storage: -25°C to 85°C (-13°F to 185°F) Operating: -15°C to 55°C (5°F to 131°F) < 2,000 meters Amplitude: 0.35mm, Frequency: 10 to 55 Hz (IEC/EN 60-068-2-6) Per IEC/EN 60 529. Housing: IP40; Terminals IP20 UL 94V-0 Thermoplastic; Din mount 35 mm x 7.5 mm 205g (7.23 oz.) CSA, cULus file E107778, CE, RoHS, TUV 2 2 stranded ferruled (isolated) or 2 x 1.5 mm2 stranded ferruled (isolated) DIN 46 228-1/Terminal Designation per EN 50 005 Wire Connections 1x4 mm solid or 1 x 2.5 mm 2/-3/-4 or 2 x 2.5 mm2 solid per DIN 46 228-1/-2/-3 /-4 Wire Fixing Plus-minus terminal screws M3.5 box terminals with wire protection or cage clamp terminals. Input Specifications Nominal Voltage Voltage Range 24V AC/DC AC: 0.85 to 1.1 UN At 10% residual ripple: 0.9 to 1.1 UN; At 48% residual ripple: 0.85 to 1.1 UN Maximum Consumption Nominal Frequency Control Current Overvoltage Protection 24VAC/DC: 1.8VA 50 to 60 Hz Control current typ. at 24V over 2 relays: 75 mA Internal VDR (Voltage Dependent Resistor) Output Specifications Electrical Contact Life Mechanical Life Contact Type Operate/Release Time Nominal Output Voltage Thermal Current (Ith) Short Circuit Strength Switching Capacity IEC/EN 60 947-5-1 Switching Frequency To AC15 at 2 A,230V: 105 switching cycles IEC/EN 60 947-5-1 20 x 106 switching cycles 5 N.O. positively driven and 1 N.C. relay contacts (N.O. contacts are safety contacts) Operate typ at UN: 20 m.; Release typ at UN: 35 ms. 250VAC Max. 5A per contact. See continuous current limit curve in installation manual. Max fuse rating:10A gl (IEC/EN 60 9470-5-1); Line circuit breaker: B6A AC 15: N.O. contacts: 3A/230V; N.C. contacts: 2A/230VAC DC 13: N.O. contacts: 4A/24V; N.C. contacts: 4A/24VDC; N.O. contact: 8A/24V >25x103 ON: 0.4s, OFF: 9.6s Max. 1,200 switching cycles/hr Book 3 (14.3) eSA-186 Safety Electrical Components 1-800-633-0405 Prices as of April 27, 2016. Check Web site for most current prices. Dold LG5929 Extension Module Company Information Terminal Blocks Power Distribution Blocks Dimensions mm [in] Wiring LG5929 Block Diagram Wiring Accessories 13 23 33 43 53 Y1 A1(+) A2(-) 24V ZIPLink Connection System Multi-wire Connectors K1 Sensor Cables and Connectors 24V K2 M12 Junction Blocks A3(+) A4(-) Panel Interface Connectors 14 24 34 44 54 Y2 Wiring Duct Cable Ties Wire Applications Bulk Multi-conductor Cables L1 Wire Management Products Emergency Stop Power Supplies A1(+) S11 S12 S22 13 23 DC Converters .. Transformers and Filters LG5925 A2(-) S21 S33 S34 14 24 .. Circuit Protection On Tools Y1 Y2 A1(+) A3(+) 13 23 33 Test Equipment 43 Enclosures LG5929/100 A2(-) N A4(-) 14 24 34 Enclosure Climate Control 44 Safety: Electrical Components Contact multiplication with LG 5929/100 Safety: Protective Wear Terms and Conditions *Note: W hen switching inductive loads, surge suppressors are recommended. Book 3 (14.3) www.automationdirect.com/safety Safety Electrical Components eSA-187 Prices as of April 27, 2016. Check Web site for most current prices. Safety Products Warning: Safety products sold by AutomationDirect are Safety components only. The purchaser/installer is solely responsible for the application of these components and ensuring all necessary steps have been taken to assure each application and use meets all performance and applicable safety requirements and/or local, national and/or international safety codes as required by the application. AutomationDirect cannot certify that our products, used solely or in conjunction with other AutomationDirect or other vendors’ products, will assure safety for any application. Any person using or applying any products sold by AutomationDirect is responsible for learning the safety requirements for their individual application and applying them, and therefore assumes all risks, and accepts full and complete responsibility, for the selection and suitability of the product for their respective application. AutomationDirect does not provide design or consulting services, and cannot advise whether any specific application or use of our products would ensure compliance with the safety requirements for any application. Book 3 (14.3) eSA-96 Safety Electrical Components 1-800-633-0405