Cooper Crouse-Hinds ® PowerPlus™ Panelboards L i g h t i n g a n d H e a t Tr a c i n g E P L S e r i e s ( D i v. 1 ) D 2 L S e r i e s ( D i v. 2 ) EPLCN D2LBS (INVERTED) PowerPlus D2L/EPL series panelboards provide distributors, engineers, contractors, and end-users with the ideal solution for the protection of lighting and heat tracing circuits. Tailored toward simplicity of installation, ease of maintenance, nearly infinite configurations for numerous applications, and reliable peace-of-mind performance, this offering is designed and manufactured as the industry's safest and most dependable panelboard for hazardous area locations. EPLCA PowerPlus™ Panelboards This corrosion-resistant Type 4X breather and drain comes standard with all D2L/EPL panelboards. This permits all models to maintain their Type 4 (Type 4X with suffix S752) rating while utilizing a breather/ drain solution to drain internal condensation while protecting against ingress of rain and hose water. D2L/EPL panels come standard with a high-quality silver-plated copper buss system. This provides highefficiency current flow between the main feed and branch breakers. D2L/EPL panels are available with GFI and/or EPD breakers. This 21position electrical test circuit allows for testing of GFI, EPD, or a combination of both in one panel. Each branch and main breaker handle is provided with lockout/tagout capability, which provides safety and complies with OSHA lockout/ tagout requirements. This allows for locking in the ON or OFF position for standard maintenance checks. Spring-loaded, quick-release, captive stainlesssteel cover bolts come standard. This design prevents damage to the flat joint flame path when opening and closing the cover while providing visual identification of bolt engagement. D2L/EPL panels are available with an optional hinged stainlesssteel ice shield. This ice shield solution prevents ice and snow build-up on breaker handles to allow for proper handle function in cold/wet climate applications. (cut away photo) Stainless-steel hinges are engineered to provide maximum stability and allow the cover to swing fully open. This avoids misalignment of cover to the body of the enclosure and prevents the cover from obstructing interior access. 2 EPLCN Integrated steel lifting eye is mounted on the top side of each D2L/EPL panel. This provides a stable lifting position to ensure ease of mounting during the installation process. D2L/EPL cast enclosures are manufactured with an external flange design. This design allows for a wide unobstructed cover opening and provides a completely accessible interior for ease of maintenance and wiring. Superior self-aligning breaker operators are designed for both field and factory installation. This patent-pending design guarantees proper handle alignment when closing the cover. All panels with terminal housings are factory sealed* and fully wired for maximum available circuits. This allows D2L/EPL models the ability to have additional breakers field installed while maintaining their factory seal. All terminal blocks come fully wired with each contact numbered for easy connecting of branch entries. Heavy-guage 316L stainlesssteel terminal housings (D2LBS and D2LCS series) are supplied with three removable gland plates to be used with Myers® hubs. This design allows for the flexibility of factory- or fielddrilled openings for hubs. D2LBS (INVERTED) D2L series lighting and heat tracing panelboards offer an industrial-grade 316L stainlesssteel terminal housing as standard. This design offers an increased internal volume with a removable front cover for easy access during field installation and maintenance. A cast aluminum terminal housing is standard on EPL panels and available on D2L panels. Stainless-steel terminal housings offer a high-integrity gasket, providing a watertight seal to meet enclosure Type 4/CSA ENC. 4/ IP65 requirements. This provides superior protection of enclosed wiring against water and corrosion. Cast aluminum enclosures are also gasketed providing a NEMA 4 watertight seal. *Conduit entries 2" or larger in Class I, Div. 1 Group B must be sealed within 18" of enclosure. 3 PowerPlus™ Panelboards PowerPlus factory-sealed panelboards provide flexibility and labor savings when installed, and for future changes in the field. Panels are prewired to maximum circuit capacity and ratings with field-replaceable factory-sealed components. APPLICATIONS: ELECTRICAL RATINGS: EPL/D2L PowerPlus Panelboards are used: • in areas subject to weather, dampness, and corrosion Branch Breakers (120/240VAC Quicklag® Bolt-on) Trip Ratings: 1, 2 & 3-pole 10, 15, 20, 25, 30, 35, 40, 45, 50 amp (available in all breaker spaces in panel) 55, 60, 70, 80, 90, 100 amp (only 3 breaker spaces available for 55 to 100 amp branch breakers) • for branch power distribution and circuit protection to motors, valves, pumps, lighting, heat tracing, receptacles, etc. • GFI type, 1 & 2-pole (5mA sensitivity) 15, 20, 25, 30, 40 (50 amp – available 2-pole only) • for indoor and outdoor applications in petroleum refineries, chemical and petrochemical plants, and other process industry facilities where similar hazards exist • EPD type, 1 & 2-pole (30mA sensitivity) 15, 20, 25, 30, 40 (50 amp – available 2-pole only) • in areas made hazardous by the continuous or abnormal presence of flammable gases, vapors, and combustible dusts • to accommodate up to 100 amp branch loads (only 3 circuits), balance is up to 50 amps • HID Type, 1 & 2-pole, 15, 20, 25, 30, 35, 40, 50, 60 • Available with GFI, EPD, or a combination of both in one panel with a 21 position electrical test circuit Main Breaker Trip Ratings: CERTIFICATIONS AND COMPLIANCES: EPL Series (Division 1): • NEC/CEC: Class I, Division 1 & 2, Groups B†,C,D Class I, Zone 1 & 2, IIB+ Hydrogen† Class II, Division 1, Groups E,F,G Class II, Division 2, Groups F,G Class III • 2- or 3-pole • Size B: 10 to 100 amps • Size C: 10 to 225 amps Main Lugs: • Size B and C: 225 amp STANDARD MATERIALS AND FINISHES: • NEMA/EEMAC: 3, 4, 4X*, 7B†CD, 9EFG, 12 • CSA Enc. 3, 4, 5 • Breaker enclosure body and cover – copper-free aluminum • UL Standard: 67, 877 • Terminal housing – Type 316L stainless-steel (D2LBS and D2LCS only), copper-free aluminum (EPL, D2LBA & D2LCA) • cUL (to CSA Standard C22.2 Nos. 29 & 30) 4 • IP65 • Gasket – neoprene (cast aluminum enclosures), Foam-in-place (stainless-steel enclosure) D2L Series (Division 2): • Operating handles – die-cast aluminum (copper-free) • NEC/CEC: Class I, Division 2, Groups B†,C,D Class I, Zone 2, IIB+ Hydrogen† Class II, Division 2, Groups F,G Class III • Operating shafts and bushings, cover bolts, washers, and retractile springs – stainless-steel • NEMA/EEMAC: 3, 4, 4X*, 7B†CD, 12 • Hinges – Type 316 stainless-steel • CSA ENC. 3, 4, 5 • Chassis – silver-plated copper • UL Standard: 67, 877 • Breather and drain – Type 316 stainless-steel • cUL (to CSA Standard C22.2 Nos. 29 & 30) • Breather cap – Delrin® non-metallic material • IP65 • Neutral and ground bar – tin-plated aluminum † Group B and IIB + Hydrogen is standard on all EPL and D2L panels, but requires special brackets to be installed on breakers. To order with brackets installed at factory, add suffix -GB. For field installable kit order EPL-GB-KIT separately. * NEMA 4X rating is available when ordered with suffix S752 or S753. Delrin® is a registered trademark of DuPont • Circuit breaker operators – non-metallic • Lifting bracket – electrogalvanized cold rolled steel OPTIONS: ACCESSORIES: To add the following features to the panelboard, add a dash and then the suffix to the catalog number. Multiple suffixes should be added in alpha-numeric order. Field-installable gland plates with factory-provided aluminum Myers Hubs for the D2L stainless-steel terminal housing (one 3-inch hub and 12 branch entry hubs – size dependent upon suffix, each kit includes 3 gland plates, one for the top or bottom and 1 for each side): Space heater (120/240V) . . . . . . . . . . . . . . . . . . . . . . . . R22 Square-head plugs on all conduit openings . . . . . . . . . . . . . SP Epoxy powder coat finish, external . . . . . . . . . . . . . . . . . S752 Epoxy powder coat finish, internal and external . . . . . . . . S753 Recess-head plugs on all conduit openings . . . . . . . . . . . . . RP Stainless-steel breaker operator cover (ice shield) . . . . . . . .HG Group B Kit factory installed . . . . . . . . . . . . . . . . . . . . . . . GB GFI breakers (see ordering example) . . . . . . . . . . . . . . . . . . G EPD breakers (see ordering example) . . . . . . . . . . . . . . . . . . E HID breakers (see ordering example) . . . . . . . . . . . . . . . . . . H Ambient compensated breakers (50°C) . . . . . . . . . . . . . . . . V (i.e. D2LCS324V) A standard panelboard has conduit openings for power and branch circuits on top. • To order a panelboard with main power feed from the bottom of breaker housing, and branch entries on top, (Alternate) add . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -A • To order an inverted panelboard with conduit openings for power and branch circuits on the bottom, (Inverted) add . . . -I • To order an inverted panelboard with main power feed on top and branch entries on the bottom, (Alternate inverted) combine the above options . . . . . . . . . . . . . . . . . . . . . . -A-I ¾" branch entry hub. . . . . . . . . . . . . . . . . . . .D2L-HUB2-KIT 1" branch entry hub . . . . . . . . . . . . . . . . . . . .D2L-HUB3-KIT 1½" branch entry hub. . . . . . . . . . . . . . . . . . .D2L-HUB5-KIT Replacement gland plate (no hubs) . . . . . . . . . .D2L-HUB0-KIT • Extra circuit-breaker operator assemblies for 1-pole or 3-pole breakers (Qty. 1): EPL-HDL13 (handle kits include operating handle, shaft, bearing, pin, and non-metallic slider) • Extra circuit-breaker operator assemblies for 2-pole breakers (Qty. 1): EPL-HDL2 (handle kits include operating handle, shaft, bearing, pin, and non-metallic slider) • Replacement cover plugs for unused circuit breaker positions (Qty. 5): EPL-OP-PLG • Kit for Group B, standard panels less GB suffix are good for Group B, but it is required to install brackets on breakers. To order brackets factory installed add suffix -GB. For field installable kit order: EPL-GB-KIT • Stainless-steel breaker operator cover to protect operators from ice build-up: – Kit for Size B panel: EPL-HG24-KIT – Kit for Size C with no main breaker or main breaker 100 amps or less: EPL-HG42-KIT – Kit for Size C with 110 amp to 225 amp main breaker: EPL-HG36-KIT • Space Heater Kit: EPL-R22-KIT • Mounting plate kit for cast-aluminum terminal housing to adapt depth of terminal housing to same depth as breaker enclosure: EPLA-MTG-KIT* • Mounting plate kit for stainless-steel terminal housing to adapt depth of terminal housing to same depth as breaker enclosure: D2LS-MTG-KIT* *note that the weight of the panel is sufficiently supported by mounting of the breaker enclosure D2L Panelboard with inverted option (-I) 5 PowerPlus™ Panelboards ORDERING INFORMATION: Figure 1: Base Panelboard Catalog Numbers 1. Select the base panelboard catalog number from Figure 1. EPL and D2L Factory Sealed 120/240 Lighting Panelboards • Determine phase (available with single-phase or threephase wiring) • Determine a total even number of breaker spaces needed to complete your desired lighting panelboard NOTE: Three-pole breaker Two-pole breaker Two-pole GFI (or EPD) breaker Single-pole breaker Single-pole GFI (or EPD) breaker = 3 breaker spaces } } = 2 breaker spaces = 1 breaker space • Review Table A on page 7 to determine panel size • If GFI or EPD breakers are to be included insert ‘‘G’’ and/or ‘‘E’’ after base catalog number and review Table B (e.g., D2LBS318G) • If ambient compensated breakers are to be supplied insert ‘‘V’’ after base catalog number (e.g., D2LBS318V). All breakers will be supplied ambient compensated • If HID breakers are to be included insert ‘‘H’’ after base catalog number (e.g., D2LBS318H) DIVISION 1‡ (w/cast aluminum terminal box) DIVISION 2‡ (w/sheet 316L Stainlesssteel terminal box) 1 Phase 3 Wire 3 Phase 4 Wire 1 Phase 3 Wire 3 Phase 4 Wire 2 EPLBA102 EPLBA302 D2LBS102 D2LBS302 4 EPLBA104 EPLBA304 D2LBS104 D2LBS304 6 EPLBA106 EPLBA306 D2LBS106 D2LBS306 8 EPLBA108 EPLBA308 D2LBS108 D2LBS308 10 EPLBA110 EPLBA310 D2LBS110 D2LBS310 12 EPLBA112 EPLBA312 D2LBS112 D2LBS312 14 EPLBA114 EPLBA314 D2LBS114 D2LBS314 16 EPLBA116 EPLBA316 D2LBS116 D2LBS316 18 EPLBA118 EPLBA318 D2LBS118 D2LBS318 20 EPLBA120 EPLBA320 D2LBS120 D2LBS320 20 EPLCA120 EPLCA320 D2LCS120 D2LCS320 22 EPLBA122 EPLBA322 D2LBS122 D2LBS322 22 EPLCA122 EPLCA322 D2LCS122 D2LCS322 24* EPLBA124 EPLBA324 D2LBS124 D2LBS324 24 EPLCA124 EPLCA324 D2LCS124 D2LCS324 2. Using three-pole breakers first, designate circuit breakers for your lighting panelboard application: 26 EPLCA126 EPLCA326 D2LCS126 D2LCS326 28 EPLCA128 EPLCA328 D2LCS128 D2LCS328 • Place an asterisk (*) before each quantity of circuit breakers 30 EPLCA130 EPLCA330 D2LCS130 D2LCS330 • First # is number of breakers needed (less than 10 insert 0 before quantity. e.g., 09) 32 EPLCA132 EPLCA332 D2LCS132 D2LCS332 34 EPLCA134 EPLCA334 D2LCS134 D2LCS334 36 EPLCA136 EPLCA336 D2LCS136 D2LCS336 38 EPLCA138 EPLCA338 D2LCS138 D2LCS338 40 EPLCA140 EPLCA340 D2LCS140 D2LCS340 • If multiple breaker options are required please insert in alpha numeric order (e.g. D2LBS318EGHV) • Second # is number of poles (start with three-pole breakers) NOTE: Single-phase panelboards can have single- or two-pole breakers. Three-phase panelboards can have single-, two- or three-pole breakers. • Third # is the ampere rating needed (start with highest ampere rating) • Insert ‘‘G’’ for GFI, ‘‘E’’ for EPD or ‘‘H’’ for HID type breakers, if desired 3. For additional circuit breakers repeat step 2. If there are more three-pole breakers with different amp ratings, continue with three-pole designations. Otherwise continue with two-pole circuit breakers, and then single-pole breakers. 4. To add a main breaker, insert a dash (-), the number of poles (2 or 3), an ‘‘M’’ to indicate main breaker, then indicate the amp rating. (See ‘‘electrical ratings’’ for trip ratings available.) Threephase panelboards can only have a three-pole main breaker. If no main breaker is specified, the panelboard will have main lugs. No suffix needed in catalog number for main lug only. Lighting panelboards are available with three 100 amp branch spaces maximum with balance up to 50 amps. For future spaces, to provide for operating mechanism without breaker write 00 (Example: One 3-pole mechanism without breaker: 01300). Unused breaker positions without designations will be blank and plugged, complete panel will be prewired for future breaker installations. 6 Breaker Spaces Needed 42* EPLCA142 EPLCA342 D2LCS142 D2LCS342 (Empty°) EPLBA100 EPLBA300 D2LBS100 D2LBS300 (Empty°) EPLCA100 EPLCA300 D2LCS100 D2LCS300 ‡ EPL Panels are provided as standard with a cast aluminum terminal housing, to order less terminal housing change the ‘‘A’’ in base part number to ‘‘N’’ (i.e. EPLCA342 becomes EPLCN342). D2L Panels are provided as standard with a sheet stainless-steel terminal housing, to order with a cast aluminum terminal housing change the ‘‘S’’ in base part number to ‘‘A’’ (i.e. D2LCS342 becomes D2LCA342). * Items not available with a main circuit breaker. ° Empty enclosures provided with a main lug only, accommodations for a main breaker may be provided but must be specified (add suffix -2M00 or -3M00). Empty enclosures are not available with GFI or EPD breakers. Panels to accommodate GFI or EPD breakers must be ordered with at least one such breaker installed. Table A – Panel Capacity Maximum Number of Breaker Spaces: Max. No. of Breaker Spaces Panel Size B C# Available w/GFI, EPD Branch Protection Yes Yes Yes Available Main Breaker Ampacity Up to 100 Up to 100 110 to 225 w/Main Breaker two-pole three-pole 22 21 40 39 36 36 w/Main Lug Only 24 42 # Size C panels with main breaker rated up to 100 amps uses a back-fed branch breaker. Size C panels with main breaker rated from 110 amps to 225 amps has a dedicated location for main breaker. Size C ordered with suffix 2M00 or 3M00 are provided with 36 branch circuits for maximum breaker ampacity. Table B – To Size Panels with GFI or EPD Branch Breakers Maximum number of GFI or EPD breakers Panel Size SinglePole TwoPole with Main Lug or Main Breaker B 21 12 (10 with 3 pole MCB, 11 with 2P MCB) C 21 14 Each factory-sealed panel is equipped with 42 load wires for GFI/ EPD breakers and any combination with standard branch breakers. Determine the total number of load wires required to complete your panel. You may not exceed 42 load wires. Single-pole breaker Single-pole GFI (or EPD) breaker Two-pole breaker Two-pole GFI (or EPD) breaker Three-pole breaker = = = = = Load Wires Required 1 2 2 3 3 Maximum total: 42 load wires Lighting Panelboard Catalog Number Example Lighting panelboards can be furnished with an assortment of breaker ratings and pole configurations. Assortments may be ordered by adding the number of poles and amp rating designations to the catalog number. Example would be ordered as: Example: A three phase, Class I, Division 2, Groups B, C, D lighting panelboard with: (1) three-pole breaker with 100 amp rating. (2) two-pole breakers–both with 30 amp GFI personnel protection. (20) one-pole breakers–with 20 amp rating. Three-pole main breaker–with 225 amp rating. D2L CS 3 28 G * 01 3 100 *02230G *20120 –3M225 –GB 1. Select Division 2 Lighting panelboard – D2L a. CS – size C enclosure with stainless steel terminal housing to handle 27 circuits with main circuit breaker and GFI protection b. 3 phase c. (1) three-pole = 3 breaker spaces + (2) two-pole (GFI) = 4 breaker spaces + (20) single-pole = 20 breaker spaces 27 breaker spaces If odd # round up to even #: 28 breaker spaces d. GFI breakers included (Use ‘‘E’’ for EPD) Verify load wires required w/panel size (Table B) (1) three-pole = 3 load wires (3 wires each) (2) two-pole (GFI) = 6 load wires (3 wires each) (20) single-pole = 20 load wires (1 wire each) 29 load wires (42 load wires available) 2. Choose branch circuit breakers (three-pole first) (1) three-pole with ampere rating a. Insert Asterisk * b. Quantity is 1: 01 (if less than 10 insert 0 before quantity) c. Three-pole: 3 d. Ampere Rating is 100: 100 5. Group B kit factory installed – 4. Main Breaker –3M225 (3-pole, Main breaker, 225 Amp) 3. Additional breakers (three-pole first) (2) two-pole w/30 ampere rating (GFI) . . . . . . . . . *02230G (20) single-pole w/20 ampere rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . *20120 (For operating mechanisms with no breaker supplied, add ‘‘00’’ for amperage) For D2LBS/D2LCS Series with stainless-steel terminal housing, removeable gland plates must be field drilled to ¡ separately: Trade Size 1⁄2˝ 3⁄4˝ 1˝ 11⁄4˝ 11⁄2˝ 2˝ 21⁄2˝ 3˝ 31⁄2˝ 4˝ Zinc ST 1 ST 2 ST 3 ST 4 ST 5 ST 6 ST 7 ST 8 ST 9 ST 10 Aluminum STA 1 STA 2 STA 3 STA 4 STA 5 STA 6 STA 7 STA 8 STA 9 STA 10 Type 316 Stainless SSTG 1 SSTG 2 SSTG 3 SSTG 4 SSTG 5 SSTG 6 SSTG 7 SSTG 8 SSTG 9 SSTG 10 7 PowerPlus™ Panelboards DIMENSIONS: 6.50 (165.1) 4.66 (118.4) 2.81 (71.4) 6.50 (165.1) 1-1/2" NPT 12 PLACES 4.66 (118.4) 2.81 (71.4) 3 1/2" NPT 5.10 3.51 (129.5) (89.2) TYP. TYP. .92 (23.4) 1/2" BOLT (M12) 1.31 (33.3)TYP. 1.83 (46.5) .50 (12.7) 20.12 (511.0) 5.50 (139.7) 12.93 (328.4) APPROXIMATE CL 3/8" BOLT (M9) 11.16 (283.5) 4.00 (101.6) 61.75 (1568.5) 11.52 (292.6) APPROXIMATE 29.50 (749.3) 3 1/2" NPT ALTERNATE FEED OPTION (SUFFIX 'A') ONLY 48.63 (1235.2) 17.50 (444.5) 6.00 (152.4) 5.75 (146.0) 14.88 (377.8) TYP. 14.88 (377.8) TYP. Size C Panel (with cast terminal housing) Size B Panel (with stainless-steel terminal housing) For more information: Contact an authorized Cooper Crouse-Hinds Distributor, Sales Office or Customer Service Department: Distributed by: In the U.S.: In Canada: Cooper Crouse-Hinds P.O. Box 4999 Syracuse, NY 13221 Toll Free: 866-764-5454 (315) 477-5531 FAX: (315) 477-5179 crouse.customerctr@crouse-hinds.com Cooper Crouse-Hinds Canada Toll Free: 800-265-0502 (905) 507-4187 FAX: (905) 568-7048 For office locations outside of North America or for additional product information, visit our website at: www.crouse-hinds.com Mexico • Latin America/Caribbean • Germany • Australia • Asia • Dubai • India Solutions.Worldwide. TM 4886-1206 Crouse-Hinds is a registered trademark of Cooper Industries, Inc. © 2006 Cooper Industries, Inc. Printed in U.S.A