by by e243698 Miniature Circuit Breakers - Type JTEC by Supplementary MINIATURE CIRCUIT BREAKERS - TYPE JTECUL CONTENTS Introduction ...................... 2 Part Number Listing .......... 3 Technical Specifications ... 4-5 CONTENTS Trip Curves ....................... 6 Introduction ....................................................... 2 Application Guidelines ........ 7 Part Number Listing .............................................. 3 Dimensions ....................... 8 Miniature Circuit Breakers – Type JTECUL Technical Specifications ................................ 4-5 Trip Curves ....................................................... 6 Application Guidelines & Dimension........................7 Cross Reference...................................................... 8 by INTRODUCTION e243698 JTEC MCB’s are premium thermal-magnetic MCB’s approved as supplementary protectors to UL1077 (CSA 235), and UL listed as manual motor starters to UL508. Anatomy of a High Performance MCB 1 2 They are available in 1, 2, 3P versions plus neutrals and offer industry standard dimensions and trip characteristics. 3 Features & Benefits. 4 12 • Certified as manual motor controllers & marked “Suitable for use as motor disconnect”. • Current/energy limiting performance minimizes damage to wiring and components. • Ratings up to 10KA and 600Vac • Fit standard 35mm DIN rail. Dual fixing mechanism allows MCB to be released from top or bottom. • Solenoid ‘hammer-trip’ mechanism and arc-control chutes for reliable fault interruption. • Wide range of field installable options. • Optional busbar system for time and labour saving installation. Busbar tie points are separate from box terminals and may be used as splitter connections if busbar not used. • ‘Trip-free’ toggle mechanism with clear on/off status. • JTEC MCB’s can be reverse fed. 11 5 10 9 7 6 8 1 - Box Terminal 2 - Busbar Aperture 3 - Hammer action Solenoid 4 - Actuator handle 5 - Moving contact 6 - Busbar aperture 7 - Box terminal 8 - Din clip 9 - Thermal element 10- Arc runner 11- Trip bar 12- Arc chamber APPLICATIONS FOR SUPPLEMENTARY MCB’S JTEC MCB’s are used wherever closer overcurrent protection of components is required than the branch circuit device is capable of providing. Supplementary devices are typically used on the load side of the branch circuit device to ‘Supplement’ the branch circuit device’s capabilities and are available in a wide range of current ratings and trip characteristics that allow them to be matched to the overcurrent requirements of individual control components. JTEC MCB’s are also suitable as manual motor controllers and can be used for direct across-the-line control of AC motors or group protection of AC motors to UL 508. They are marked “Suitable for use as motor disconnect” to meet emerging inspection requirements. JTEC MCB’s are current and energy limiting. They can reduce the heating and magnetic effects of short circuits to greatly reduced levels. Their ‘trip-free’ mechanism prevents reclosing the MCB onto a faulted circuit and provides a clear indication of a tripped unit. Their compact dimensions, ease of mounting and excellent performance make them an ideal overcurrent device for the protection of small motors, communication and computer equipment, appliances, general control circuits, solenoids and coils, lighting circuits, and resistive loads. For Branch Rated Circuit Breakers, please request bulletin JTEC489 Miniature Circuit Breakers – Type JTECUL by PART NUMBER LISTING e243698 Part Numbers Trip Characteristics B Fast Acting. Instantaneous trip response of 3 - 5X rated current (In) Use for sensitive equipment and purely resistive loads. C Normal acting. Instantaneous trip response of 5 - 10x rated current (In) Use for control circuits and mixed loads D Slow Acting. Instantaneous trip response of 10 - 20x rated current (In) Use for motor, transformer and solenoid applications. Continuous Amp Rating (A) Single Pole 0.5 1 2 3 4 6 8 10 13 16 20 25 32 40 50 63 JTECUL1B0.5 JTECUL1B01 JTECUL1B02 JTECUL1B03 JTECUL1B04 JTECUL1B06 JTECUL1B08 JTECUL1B10 JTECUL1B13 JTECUL1B16 JTECUL1B20 JTECUL1B25 JTECUL1B32 JTECUL1B40 JTECUL1B50 JTECUL1B63 JTECUL2B0.5 JTECUL2B01 JTECUL2B02 JTECUL2B03 JTECUL2B04 JTECUL2B06 JTECUL2B08 JTECUL2B10 JTECUL2B13 JTECUL2B16 JTECUL2B20 JTECUL2B25 JTECUL2B32 JTECUL2B40 JTECUL2B50 JTECUL2B63 JTECUL3B0.5 JTECUL3B01 JTECUL3B02 JTECUL3B03 JTECUL3B04 JTECUL3B06 JTECUL3B08 JTECUL3B10 JTECUL3B13 JTECUL3B16 JTECUL3B20 JTECUL3B25 JTECUL3B32 JTECUL3B40 JTECUL3B50 JTECUL3B63 0.5 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 40 50 63 JTECUL1C0.5 JTECUL1C01 JTECUL1C1.6 JTECUL1C02 JTECUL1C03 JTECUL1C04 JTECUL1C05 JTECUL1C06 JTECUL1C08 JTECUL1C10 JTECUL1C13 JTECUL1C15 JTECUL1C16 JTECUL1C20 JTECUL1C25 JTECUL1C30 JTECUL1C32 JTECUL1C40 JTECUL1C50 JTECUL1C63 JTECUL2C0.5 JTECUL2C01 JTECUL2C1.6 JTECUL2C02 JTECUL2C03 JTECUL2C04 JTECUL2C05 JTECUL2C06 JTECUL2C08 JTECUL2C10 JTECUL2C13 JTECUL2C15 JTECUL2C16 JTECUL2C20 JTECUL2C25 JTECUL2C30 JTECUL2C32 JTECUL2C40 JTECUL2C50 JTECUL2C63 JTECUL3C0.5 JTECUL3C01 JTECUL3C1.6 JTECUL3C02 JTECUL3C03 JTECUL3C04 JTECUL3C05 JTECUL3C06 JTECUL3C08 JTECUL3C10 JTECUL3C13 JTECUL3C15 JTECUL3C16 JTECUL3C20 JTECUL3C25 JTECUL3C30 JTECUL3C32 JTECUL3C40 JTECUL3C50 JTECUL3C63 0.5 1 2 3 4 6 8 10 13 16 20 25 32 40 50 63 JTECUL1D0.5 JTECUL1D01 JTECUL1D02 JTECUL1D03 JTECUL1D04 JTECUL1D06 JTECUL1D08 JTECUL1D10 JTECUL1D13 JTECUL1D16 JTECUL1D20 JTECUL1D25 JTECUL1D32 JTECUL1D40 JTECUL1D50 JTECUL1D63 JTECUL2D0.5 JTECUL2D01 JTECUL2D02 JTECUL2D03 JTECUL2D04 JTECUL2D06 JTECUL2D08 JTECUL2D10 JTECUL2D13 JTECUL2D16 JTECUL2D20 JTECUL2D25 JTECUL2D32 JTECUL2D40 JTECUL2D50 JTECUL2D63 JTECUL3D0.5 JTECUL3D01 JTECUL3D02 JTECUL3D03 JTECUL3D04 JTECUL3D06 JTECUL3D08 JTECUL3D10 JTECUL3D13 JTECUL3D16 JTECUL3D20 JTECUL3D25 JTECUL3D32 JTECUL3D40 JTECUL3D50 JTECUL3D63 Double Pole part numbering example JTECUL JTECUL- Supplementary Miniature Circuit Breakers – Type JTECUL No. Poles (1, 2, 3) 3 C 63 Trip Curve (B, C, D) Amp Rating (0.5 - 63A) Three Pole by TECHNICAL SPECIFICATIONS e243698 Auxilliary contacts Used for signalling or operating remote devices. Available as 1-NO/NC, 2 NO/NC, 1 NO/NC + signal, and 1 - NO/NC + signal + test button. Auxilliary contacts have higher switching capability than signal contacts. Part # Part # JTECULAUX1CO JTECULAUX2CO 1 changeover contact 2 changeover contacts JTECULAUXSTCO JTECULAUXSCO 1 changeover, 1 signal contact 1 changeover, 1 signal contact with test button Shunt trip Shunt trips are used to trip breaker from a remote location and are available in a wide range of popular control voltages. Part # - AC JTECULST12AC Part # - AC JTECULST24AC Part # - DC JTECULST24DC JTECULST120AC JTECULST48DC JTECULST230AC JTECULST110DC Neutral module (switched) This module is used where a non-sensing pole is desired. The neutral is operated in tandem with the main poles. Part # JTECULN2 (for 32-63A) Safety lockouts Use this lockout to lock MCB in open or closed position. Hole for padlock or seal is provided. Available in safety yellow or black. Part # Yellow Part # Black JTECLP1Yellow JTECLP1Black Feeder Busbar Use feeder bus to parallel a large number of breakers - saving wiring and labour costs. Available for single phase or 3 phase applications in16 or 20 gang models. Busbar may be cut for reduced number of poles. Can also be used with other devices (fuseholders, etc..) Single Phase Part # Description 3 Phase Part # Description BBTEC1Pcomb20 1 phase - 20 gang spade style BBTEC3Pcomb16C 3 phase 16 gang spade type BBTEC1Ppin16 1 phase - 16 gang pin style BBTEC3Ppin16 3 phase 16 gang pin type Miniature Circuit Breakers – Type JTECUL by TECHNICAL SPECIFICATIONS e243698 General Specifications JTECUL UL/CSA Standards - Supplemental protection UL1077 (CSA 235) UL Motor Disconnect standard UL508 IEC Standards IEC/EN60 898, DIN43880 Ambient temperature min/max -25* to +60* C Line load connections Reversible Mounting position any plane Degree of protection IP20 at front Mechanical life expectancy cycles 100,000 on/off cycles Electrical life expectancy cycles 6,000 on/off cycles as motor disconnect Vibration resistance G/HZ 3G’s (8-50HZ) Electrical Specifications Rated current JTECUL 0.5, 1, 1.6, 2, 3, 4, 5, 6, 8, 10, 13, 15, 16, 20, 25, 30, 32, 40, 50, 63A Amps Number of Poles Rated voltage (Volts) Rated frequency (AC) 1P, 2P, 3P 1P+N, AC 277/480V, 347/600V DC 48 V Hz 50/60Hz 3P+N 1/2 - 6A 10kA No backup fuse UL1077/ UL508 277/480Vac 8 - 63A 10kA with backup fuse Interrupting ratings (rms symm) 347/600Vac Techna self tested 48Vdc Series Rating Backup Fuse Trip curves (instantaneous trip) Tightening torque 1/2 - 63A 2kA No backup fuse 1/2 - 63A 5kA with backup fuse 1/2 - 63A 8kA No backup fuse Current limiting. CSA/UL class J 250A or less B 3 - 5X current rating C 5 - 10X current rating D 10 - 20X rating Overload response Wire range (box terminal) 8 - 63A 5kA No backup fuse 1.3X current rating in <1h AWG12- AWG3 (2.5mm2 - 25mm2) UL/CSA Nm 13-17 in/lbs (1.5-2Nm) Accessory Specifications Terminal Capacity JTECUL AWG Tightening torque #20 - #12 copper only 3-4 in/lbs , .33 - .50Nm Protection degree IP20 from front Shunt trip release coil voltages AC 12, 24, 120, 230 DC 24, 48, 110V Auxilliary contact ratings Standard pilot duty Bus Bar Specifications Amp ratings Approvals BBTEC End feed 80A Center feed 130A UL508 277/480Vac, 10kA rms Material - Conductor Copper (E-Cu-F25) Material - Insulating ABS UL 94-V0 Miniature Circuit Breakers – Type JTECUL by TRIP CURVES Tripping Characteristic of JTECUL Circuit Breaker ( In < 10A ) e243698 Tripping Characteristic of JTECUL Circuit Breaker ( In > 10A ) Trip Characteristics Short Circuit (Instantaneous) JTEC MCB’s use industry standard B, C, D instantaneous trip characteristics. Which refer to the instantaneous magnetic trip and are expressed in multiples of the breaker current rating. B Trip Curve Overload (Thermal) The thermal overload capabiltiy of the JTEC series is 130% in less than 1 hour. These overload trip times are the same for B, C and D trip curves. JTEC MCB’s are calibrated to fall as close as possible to the center of the trip curve tolerances. Each JTEC trip curve class is independently tested and approved. Instantaneous trip of 3-5X breaker current rating. Use this curve for protection of sensitive electrical/electronic equipment or where a fast acting characteristic is required. B curves are not suitable for use on circuits with inherent surge currents such as motors, transformers or generators. C Trip Curve Instantaneous trip of 5-10X breaker current rating. C curve is the ideal general purpose curve. Suitable for use on mixed circuits with some natural surges. Use for general control panel device protection. D Trip Curve Instantaneous trip of 10-20X breaker current rating. The D curve is intended for use on circuits with high inrush/ surge currents such as transformers, solenoids, small motors and capacitors. The inherent delay in the trip characteristic allows the normal surges to subside without nuisance tripping. Miniature Circuit Breakers – Type JTECUL by APPLICATION GUIDELINES e243698 General The trip curve is then chosen to match the intended application. Select breaker trip curve based on the following: B trip Sensitive electronic equipment with no inherent surges or momentary overloads • Solid state devices • Switching power supplies • Inputs and outputs for PLC’s C trip Ambient De-rating Factor 1.30 Multiple of Amp Rating To meet the Canadian Electrical Code guidelines for 80% circuit loading, JTEC MCB’s should be selected at 125% of the nominal circuit/device full load current or 100% of the connected wire ampacity, whichever is less. This will ensure that the MCB’s provide the necessary degree of overload protection. 1.20 1.10 1.00 0.90 0.80 -20C -10C 0C 10C 20C 30C 40C 50C 60C Ambient temperature Ambient Temperature De-rating JTEC MCB’s are fully rated for ambients up to 32*C. Mixed loads with some motor, transformer or solenoid content. • • • • • • • • General small panel control with mixed devices HVAC control Lighting control panels Discrete protection of lighting ballast Machine tools Mobile equipment, trailers Vending machines, ATM’s Marine electrical systems Above 32°c - apply the appropriate de-rating factor found in chart above to determine the MCB’s current carrying capability at elevated temperatures. Dimensions D trip Circuits consisting primarily of motor, transformer or solenoid/ coil content. • • • • • • 45mm Motor starters Pump control panels Compressor and pump panels Generator panels Capacitor application Transformer primary protection. 6.5 mm 44mm 60mm 96.8mm 17.5mm 77mm Multiply width by number of poles required for overall width dimension. Neutral poles and Shunt trips are same dimensions as 1P MCB’s. Auxilliary contacts are same profile but 12.7mm wide. Miniature Circuit Breakers – Type JTECUL by e243698 cROSS rEFERENCE cHART Techna JtecUL Moeller Merlin Gerin Electric FAZ Schneider C60 Tyco P&B Weidmuller H91 series GE V line Allen Bradley Bulletin ABB - S series 1492-CB JtecUL1B FAZ-B C60-1B W67X--20 - V171 1492-CB1F JtecUL2B FAZ-2B C60-2B W68X--20 - V172 1492-CB2F JtecUL3B FAZ-3B C60-3B W69X--20 - V173 1492-CB3F JtecUL1C FAZ-C C60-1C W67X--22 & 23 9925 series V071 JtecUL2C FAZ-2C C60-2C W68X--22 & 23 9925 series V072 JtecUL3C FAZ-3C C60-3C W69X--22 & 23 9925 series V073 JtecUL1D FAZ-S C60-1S W67X--210 - V371 1492-CB1H JtecUL2D FAZ-2S C60-2S W68X--210 - V372 1492-CB2H JtecUL3D FAZ-3S C60-3S W69X--210 - V373 1492-CB3H S250, S260, S270, S280, S931N, S941N, S951N, S971N 1492-CB1G 1492-CB2G 1492-CB3G Disclaimer: It is the user’s responsibility to verify the suitability of suggested alternative. New Products from Techna - Coming Soon LEDtec Series LEDtec Series 22mm LED pilot lights MultiChip LED Pilot Lights Voltages Ambient Temperature Operating Position Available Colours : 12Vdc, 24Vac/dc, 48Vac/dc,110Vac & 230Vac : -25C to +55C : All Positions : Amber, Blue, Green, Red, White •For more information on the LEDtec Series Pilot Lights request bulletin LEDtec •For information on Branch Rated MCB’s request bulletin JTEC 489 Distributor 599 Norris Crt Kingston, Ontario Canada, K7P 2R9 t: (800) 479-3875 f: (800) 866-7690 info@fusetek.com www.fusetek.com Printed in Canada Miniature Circuit Breakers – Type JTECUL