MedLux® HBTSF22 - Everbrite Lighting

HBTSF22: LED Ceiling Troffer Light - Imperial Dimensions
2x2
Drop Ceiling Grid Mount ONLY
MedLux HBTSF22
®
MRI-Safe
LED
CATALOG#
TYPE
JOB NAME
MRI-Safe 2x2 LED High-Bright Troffer
NOTES
HIGHLIGHTS
5-Year Limited Warranty
LED
100% MRI-Safe Non-Ferrous Construction
Fully-Assembled Light Boxes
LED Lightb
Dimming
Only with MedLux Proprietary Dimming Systems
Optional adder, NOT required for operation
Easy to Install
Class 2 wiring, plug-and-play connections
FIXTURE TYPE
Designed for New Construction or Retrofit
No Field Assembly of Light Boxes is Required
NOT INCLU
INCLUDED
High-Bright Troffers
Please Note: Fixtures are intended
for use as general area illumination.
ox(es)
Rated
ly in NEM APower Supp
Enclosure
nel/Fuse
ribut ion Pa
Class 2 Dist
rated)
Box (NEM Ae(s)
Power Cabl
y
ar
nd
co
Se
d Manual
an
m
ra
Diag
Inst allation
DED
Filters*
s
Component
Ceiling Gr id
ding
ol
/M
im
Tr
Decorative
n
r Connec tio
M AINS Powe Switches
s&
nt
ne
po
m
Co
Inst allation
* Available
- sold sepa
rately
23.62"
23.62"
3-D View
Notes:
1. Dimensions are in inches
2. Fixtures for indoor use and installation only
3. Troffer units are not for use in Plenum ceilings
Approx. 30" Long
16-3 round Plenum Cables
4. Troffer units are built to UL-48 specifications
5.50"
4.02"
12"
LIGHTBOX SPECIFICATIONS
CONSTRUCTION: Single piece construction consists of 0.04″ thick fabricated aluminum with riveted seams.
Leading edge of return is hemmed in order to made rigid and straight. Hems also provide a smooth, rolled
surface, which prevents scratching of graphic panels. All inner and outer surfaces receive a durable,
reflective white powder coat finish.
Power Supply
14"
DIMENSIONS: 23.62″ x 23.62″ x 5.5″
CEILING CLEARANCE: 6.0″ above the inside of the drop ceiling grid framework. Suspension ceiling
installation requirements vary. Consult with your local building authority for code compliance.
WEIGHT: 7 lb (weights do not include diffuser panel)
LIGHT SOURCE: White high-power Nichia LEDs. 80,000 hours useful life/ 50,000 L70
LUMINANCE: (surface brightness) 2571 Net Lumens (640 fc) - Measurement taken at face of translucent acrylic panel.
6"
POWER SUPPLY SPECIFICATIONS
EFFICACY (LM/WATT): 57.0
COLOR TEMPERATURE: 3500°K (+/- 600°K), CRI: 85
DIFFUSER PANEL: Translucent acrylic (Satin Ice - 80% light transmission) - 23.75″ x 23.75″ x 1/4″
ELECTRICAL CONNECTIONS: Single pigtail connection system
INPUT VOLTAGE: 48 Volts DC
INPUT CURRENT: 0.94 Amps
INPUT POWER: 45 Watts
DIMMING: Dimming is not required for operation. Optional ADDER - proprietary PWM dimming system or 0-10 volt
control signal. MedLux troffers are not compatible with any other type of wall dimmer. Dimmer Control Keypad can
be installed in or out of the scan room and mounts in standard wall box with minimum 3″ depth. Dimming signals are
Class 2 low voltage, routed via CAT5 cables with RJ45 connections. Smooth dynamic operation without change in
color temperature throughout the dimming range. Each dimming zone requires a separate dimmer.
SAFETY AGENCY LISTING: File No. E6733 Vol. 1 Sec. 75 USL/CUL per UL48; CSA C22.2 No. 207
MODEL:
DIMENSIONS:
WEIGHT:
POWER SUPPLY TYPE
POWER SUPPLY TYPE
3
1
ELT150-48
ELT600-48
14″ x 12″ x 6″
14″ x 12″ x 6″
30 LB
30 LB
INPUT VOLTAGE:
120/240 Volts AC
120/240 Volts AC
INPUT CURRENT:
1.3/0.65 Amps (max)
6.4/3.2 Amps (max)
INPUT POWER:
156 VA
770 VA
OUTPUT VOLTAGE:
48 Volts DC
48 Volts DC
OUTPUT CURRENT:
2.8 Amps (max)
11.3 Amps (max)
Must be used with current limiter module for Class 2 installations.
DIMMING CONTROLS
CR
SR
Each keypad controls a single zone of up to 12 - 2x2s.
Each zone requires a separate dimmer.
DD
3.87 [98.2]
4.33 [110]
MedLux® troffer fixtures will not interface with a Lighting
Control Panel, such as Lutron without the use of our
proprietary XLIM module. A separate XLIM module is
required for each dimming zone.
1.50 [38]
2.21 [56.2]
3-Way dimming is not currently available.
Ø.179 [4.55}
4 PLACES
CR: MEDLUX® CONTROL ROOM DIMMER KIT RLD-179CR (Dimmer Control Keypad in Control Room)
RLD-179CR - CONTROL ROOM DIMMER KIT CONTENTS
2
1
ITEM#
PART#
DESCRIPTION
1
RLD-79
Dimmer Assembly
2
EWI000024
PLTC, #18AWG, 2-Twisted Pair, 100FT
RLD-133
Transformer Kit, 16VAC
COVER PLATE
RLD-133M
TRANSFORMER
RLD-133T
3
EWI000003
CABLE
3
QTY
1
1
1
[1] RLD-133T Transformer/[1] EWI000003 Cable, 15FT/[1] RLD-133M Cover Plate
RLD-133 TRANSFORMER KIT
SR: MEDLUX® SCAN ROOM DIMMER KIT RLD-179SR (Dimmer Control Keypad in Scan Room)
RLD-179SR - SCAN ROOM DIMMER KIT CONTENTS
2
1
ITEM#
PART#
DESCRIPTION
1
RLD-79
Dimmer Assembly
QTY
2
EWI000003
Cable, Plenum, 16-3 CL3P, 50FT
1
1
DD: XLIM DIGITAL DIMMER KIT RLD-193 (Dimmer Control Keypad in Control Room ONLY) Compatible with most 0-10V, PWM, or DSCI (Digital Serial Communications Interface) devices
RLD-193 - DIGITAL DIMMER KIT CONTENTS
MODE JUMPER
COM-SEL
(0-10V SELECT)
#20 AWG WIRE
1
ITEM#
COVER PLATE
RLD-133M
1
TRANSFORMER
RLD-133T
1.41 [35.8]
2
1.02 [25.8]
2
EWI000003
CABLE
PART#
DESCRIPTION
RLD-183
XLIM Dimmer Interface Assembly
QTY
RLD-133
Transformer Kit, 16VAC
1
1
[1] RLD-133T Transformer/[1] EWI000003 Cable, 15FT/[1] RLD-133M Cover Plate
RLD-133 TRANSFORMER KIT
NOTE: An interface module from the lighting control panel provider may also be required.
C
ORDERING INFORMATION
Again, using the “TOTAL Troffers” (A) Find that number in the left-hand column
below and write in the corresponding
CIRCUIT count that appears to the right.
B
MODEL
SIZE
HBTSF
22
High-Bright
A
DIMMING CONTROLS
TOTAL Troffers
(A)
01 - 12
STANDARD
(Imperial)
MRI-SAFE
TOTAL Troffers
(A)
Enter 1 or 3
2' x 2'
CEILING
Enter 1 to 06
POWER SUPPLY TYPE
–
Troffer
NUMBER OF CIRCUITS
Using “TOTAL Troffers” (A) - Find that
number in the left-hand column below and
write in the corresponding POWER SUPPLY
TYPE that appears directly to the right.
TOTAL Troffers
POWER SUPPLY
WATTS
QTY
NN
No Dimmer
01 - 03
3
1
150
CR
Control Room Dimmer
04 - 12
1
1
600
SR
DD
01
03
02
03
04
04
05
Scan Room Dimmer
06
06
Digital Dimmer (XLIM)
Control Room ONLY
07
07
DD: Lighting Control Panel Model#
A
HBTSF
01
02
05
DD: Lighting Control Panel MFG
SAMPLE:
22
1 2 N N
B
–
1
1
C
Please Note:
Filters are
typically supplied
by the RF Shield
provider and are
NOT included
with your order.
08
08
09
09
10
10
11
11
12
12
If needed,
filters are available
for purchase.
Facility Filter
P/N 019-00011
Signal Filter
P/N 019-00009
2
Please take a moment to provide the following project- specific information for our records, Thank You.
RF SHIELD PROVIDER
MAGNET
GE
MFG
HITACHI
PHILIPS
TOSHIBA
SIEMENS
Open
MODEL
TESLA
OTHER
1.0
1.5
3.0
BRADEN
Closed
OTHER
ETSLINDGREN
PDC
GLOBAL
PARTNERS IN
SHIELDING
IMEDCO
UNIVERSAL
SHIELDING
OTHER
Everbrite Lighting • 4949 South 110th Street
PO Box 20020 • Greenfield, WI 53220-0020
Phone: (800) 610-6053 • Fax: (414) 529-7191
email: elt@everbrite.com • www.everbritelighting.com
Manufactured in USA. Meets the Buy American requirements under the ARRA.
L
E
D
M
E
D
I
C
A
L
L
I
G
H
T
I
N
G
T
E
C
H
N
O
L
Protected under US Patent No. 7,629,570 B2. Everbrite, LLC © 2015. All rights reserved. Everbrite Lighting and MedLux are registered trademarks of Everbrite, LLC. E1380-0515 Rev. 1
Specifications are subject to change without notice. All other images, service marks, trademarks and registered trademarks shown are the exclusive property of their respective companies.
O
G
Y