Technical

advertisement
TECHNICAL DATA FILE
CBP 4090
CBP 4091
CBP 4092
CBP 4093
The compact system series CBP includes in one single item a
fixed point heating system with reduced size, which keeps the
water temperature in the radiant panels constant to the pre-set
value, mixing the high temperature water coming from the boiler
with the water in the heating panels.
A thermostatic valve with remote sensor detects the
temperature based on the pre-set value, fills the circuits with the
high temperature water so to compensate the loss of thermal
power of the radiant panels.
The compact system series CBP has been studied for small
rooms.
This type of system can supply a max thermal power of 8kW
with a ∆t of 10°C.
TECHNICAL
FEATURES
Max working pressure:
6 bar
Max working temperature:
60 °C
Max differential pressure:
1 bar
Max thermal power:
8 kW
Thermometer range:
Flowmeters visual range field:
Flowmeter measurement
precision :
CONSTRUCTIVE
FEATURES:
0 ÷ 80 °C
1 ÷ 4 l/min
± 10%
MANIFOLDS
Material of the manifold:
CW 617 N UNI-EN 12165-98
Material of the screw stem:
CW 614 N UNI-EN 12164-98
Material of the gaskets:
EPDM peroxide
FLOWMETER
Material of the body of the
flowmeter:
CW 617 N UNI-EN 12165-98
Material of the flow meter:
Thermoresistant plastic
Material of the spring:
Material of the gaskets:
Stainless steel
EPDM peroxide
VALVES
Material of the valve body:
CW 617 N UNI-EN 12165-98
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 1 di 12
TECHNICAL DATA FILE
Material of components:
Material of the handle:
CBP 4090
CBP 4091
CBP 4092
CBP 4093
CW 614 N UNI-EN 12164-98
ABS white RAL9010
THERMOMETER
Case and stem of
thermometer:
Covering:
Thermometric element:
Galvanized steel
Transparent plastic
Bimetallic spiral spring
MANUAL AIR VENT VALVE
Material of the valve body::
CW 614 N UNI-EN 12164-98
Material of the valve body::
Thermoresistant plastic
Material of the gaskets:
EPDM peroxide
SYSTEM INLET AND OUTLET TAPS
Material of the terminal body:
Material:
Material of the gaskets:
CW 617 N UNI-EN 12165-98
CW 617 N UNI-EN 12165-98
EPDM peroxide
PUMP:
Material of the pump body:
Material of the gaskets:
Material of the rotor group:
Material of the bearing:
GALVANIC
TREATMENT:
CW 617 N UNI-EN 12165-98
EPDM peroxide
Stainless steel, composite material, Carbon
Ceramic
Nickel plating finish
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 2 di 12
CBP 4090
CBP 4091
CBP 4092
CBP 4093
TECHNICAL DATA FILE
DIMENSIONAL DRAWING
Article:
Code
Size
17409002N
CBP 4090
Description:
Compact system with lockshiels, flowmeters
and mixers. Left inlet with straight valve
Connection:
Eurokonus type
A
B
C
D
E
F
G
H
L
M
N
P
R
G3/4xG3/4 EK
133
167
306
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409003N
G3/4xG3/4 EK
173
167
346
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409004N
G3/4xG3/4 EK
213
167
386
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409005N
G3/4xG3/4 EK
253
167
426
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409006N
G3/4xG3/4 EK
293
167
466
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 3 di 12
CBP 4090
CBP 4091
CBP 4092
CBP 4093
TECHNICAL DATA FILE
Article:
Code
Size
17409102N
CBP 4091
Description:
Compact system with lockshiels, flowmeters
and mixers. Left inlet with angle valve
Connection:
Eurokonus type
A
B
C
D
E
F
G
H
L
M
N
P
R
G3/4xG3/4 EK
133
167
307
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409103N
G3/4xG3/4 EK
173
167
347
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409104N
G3/4xG3/4 EK
213
167
387
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409105N
G3/4xG3/4 EK
253
167
427
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409106N
G3/4xG3/4 EK
293
139
467
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 4 di 12
CBP 4090
CBP 4091
CBP 4092
CBP 4093
TECHNICAL DATA FILE
Article:
Code
Size
17409202N
CBP 4092
Description:
Compact system with lockshiels, flowmeters
and mixers. Right inlet with straight valve
Connection:
Eurokonus type
A
B
C
D
E
F
G
H
L
M
N
P
R
G3/4xG3/4 EK
133
167
306
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409203N
G3/4xG3/4 EK
173
167
346
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409204N
G3/4xG3/4 EK
213
167
386
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409205N
G3/4xG3/4 EK
253
167
426
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409206N
G3/4xG3/4 EK
293
167
466
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 5 di 12
CBP 4090
CBP 4091
CBP 4092
CBP 4093
TECHNICAL DATA FILE
Article:
Code
Size
17409302N
CBP 4093
Description:
Compact system with lockshiels, flowmeters
and mixers. Right inlet with angle valve
Connection:
Eurokonus type
A
B
C
D
E
F
G
H
L
M
N
P
R
G3/4xG3/4 EK
133
167
307
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409303N
G3/4xG3/4 EK
173
167
347
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409304N
G3/4xG3/4 EK
213
167
387
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409305N
G3/4xG3/4 EK
253
167
427
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
17409306N
G3/4xG3/4 EK
293
139
467
148
40
G3/4EK
G3/4EK
-
21
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 6 di 12
TECHNICAL DATA FILE
COSTRUCTION:
CBP 4090
CBP 4091
CBP 4092
CBP 4093
1. Return manifold
2. Inlet manifold
3. Regulation lockshiel (boiler inlet)
4. No-return valve
5. Thermostatizable valve (boiler return)
6. Circulation pump
7. Inlet – outlet tap
8. Thermometer
9. Manual air drain valve
10. Cap
11. Security thermostat
12. Fixing device for the thermostatic head
probe
13. Thermostatic head with remote sensor
HYDRAULIC CONNECTION SCHEME
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 7 di 12
TECHNICAL DATA FILE
CBP 4090
CBP 4091
CBP 4092
CBP 4093
FLOW DIAGRAM
ELBOW
N° TURN
KV
1
1
0.22
2
1 + 1/2
0.31
3
2
0.48
4
2 + 1/2
0.59
5
3
0.68
6
3 + 1/2
0.74
7
4
0.81
8
4 + 1/2
0.85
9
ALL OPEN
0.87
Max suggested flow:
PUMP TECHNICAL
FEATURES:
ARTICLES
CBP 4090; CBP 4091; CBP4092; CBP 4093
(for single hole)
750 l/h (on the manifold)
Max working pressure:
Liquid temperature:
10 bar
-10 °C ÷ +95 °C
Engine:
with sferical rotor/stator with permanent
magnets EC type with variable speed
Supply:
220-240 V, 50-60 Hz
Insulation class:
Grade of protection:
F
IP 44
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 8 di 12
TECHNICAL DATA FILE
CBP 4090
CBP 4091
CBP 4092
CBP 4093
FLOW DIAGRAM:
ELECTRICAL CONNECTION
SECURITY
THERMOSTAT:
Connect the thermostat following the chart below, note:
 Terminal C: common entry
 Terminal 1: opens the circuit as the temperature increases
 Terminal 2: closes the circuit as the temperature increases
Normally in the heating systems connect the user to terminal C and 1 of the
thermostat
OPERATING INSTRUCTION
Installation of the thermostatic head for the fixed point:
 Remove the protection cap on the thermostatizable valve.
 Set the thermostatizable valve to the max value, to ease the installation, and
screw it on the valve.
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 9 di 12
CBP 4090
CBP 4091
CBP 4092
CBP 4093
TECHNICAL DATA FILE
 Place the head bulb in the fixing device
 To regulate the flow:
o Unscrew the ABS “A” cap
o With a socket head screw CH.6 gently close the obturator “B”;
o Open the obturator with the same number of turn sas those shown in the
flow diagram.
o Screw back the ABS “A” cap
The flow is indicated in the flowmeters by the top of the ball cock .
NOTE: after the test for pressure of the system is highly recommended to remove
the pressure. A difference in pressure between inet and outlet of the valve, higher
than 1 bar could cause the misplacement of the O-ring tightness.
WALL BOXES
Article:
Description:
Code
68560352
Size
310x510x88
CF 479
Universal wall box with plastic base,
complete with blocking manifolds support,
simple and modular, coplanar and
distribution.
A
B
C
D
E
F
G
H
L
M
N
P
R
310
510
330
530
88
350
550
10
-
-
-
-
-
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 10 di 12
TECHNICAL DATA FILE
CBP 4090
CBP 4091
CBP 4092
CBP 4093
SPECIFICATION
Pre assembled thermical regulation group with a fixed point, 2 to 6 outlets. Body in CW614. Hydraulic
tightness in EPDM peroxide. Head connection male G3/4 Male Eurokonus, axel base 148mm.
Connections G3/4 Male Eurokonus, axel base 40mm. Liquids to be employed: water and glycole, max
percentage of glicole30%. Max working pressure 6bar. Max fluid temperature 60°C. Consisting of
 Inlet manifold complete with lockshield for the flow regulation
 Return manifold complete with flowmeter with graduated scale 1÷4l/min. Accuracy ±10%.
 Angle regulation lockshield with connection G3/4 male Eurokonus complete with no-return
valve. Inlet connection to boiler from left.
 Angle thermostatizable valve with connection G3/4 male Euroconus. Return connection to
boiler from left.
 Circulation pump 15-3 with permanent magnet, energy class A
 Contact security thermostat, regulation range 0 °C±90 °C. Protection grade IP20.
 Thermometer for the control of the inlet temperature to the radiant panel.
 Manual air drain valve and inlet-outlet water tap.
 Fixing device for the thermostatic probe.
Article code:
see table with dimensional drawing
Pre assembled thermical regulation group with a fixed point, 2 to 6 outlets. Body in CW614. Hydraulic
tightness in EPDM peroxide. Head connection male G3/4 Male Eurokonus, axel base 148mm.
Connections G3/4 Male Eurokonus, axel base 40mm. Liquids to be employed: water and glycole, max
percentage of glicole30%. Max working pressure 6bar. Max fluid temperature 60°C. Consisting of
 Inlet manifold complete with lockshieldl for the flow regulation
 Return manifold complete with flowmeter with graduated scale 1÷4l/min. Accuracy ±10%.
 Straight regulation lockshield with connection G3/4 male Eurokonus complete with no-return
valve. Inlet connection to boiler from right.
 Straight thermostatizable valve with connection G3/4 male Euroconus. Return connection to
boiler from right.
 Circulation pump 15-3 with permanent magnet, energy class A
 Contact security thermostat, regulation range 0 °C±90 °C. Protection grade IP20.
 Thermometer for the control of the inlet temperature to the radiant panel.
 Manual air drain valve and inlet-outlet water tap.
 Fixing device for the thermostatic probe.
CBP 4091
Pre assembled thermical regulation group with a fixed point, 2 to 6 outlets. Body in CW614. Hydraulic
tightness in EPDM peroxide. Head connection male G3/4 Male Eurokonus, axel base 148mm.
Connections G3/4 Male Eurokonus, axel base 40mm. Liquids to be employed: water and glycole, max
percentage of glicole30%. Max working pressure 6bar. Max fluid temperature 60°C. Consisting of
 Inlet manifold complete with lockshiedl for the flow regulation
 Return manifold complete with flowmeter with graduated scale 1÷4l/min. Accuracy ±10%.
 Straight regulation lockshield with connection G3/4 male Eurokonus complete with no-return
valve. Inlet connection to boiler from left.
 Straight thermostatizable valve with connection G3/4 male Euroconus. Return connection to
boiler from left.
 Circulation pump 15-3 with permanent magnet, energy class A
 Contact security thermostat, regulation range 0 °C±90 °C. Protection grade IP20.
 Thermometer for the control of the inlet temperature to the radiant panel.
 Manual air drain valve and inlet-outlet water tap.
 Fixing device for the thermostatic probe.
Article code:
see table with dimensional drawing
CBP 4090
see table with dimensional drawing
CBP 4092
Article code:
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 11 di 12
TECHNICAL DATA FILE
see table with dimensional drawing
Pre assembled thermical regulation group with a fixed point, 2 to 6 outlets. Body in CW614. Hydraulic
tightness in EPDM peroxide. Head connection male G3/4 Male Eurokonus, axel base 148mm.
Connections G3/4 Male Eurokonus, axel base 40mm. Liquids to be employed: water and glycole, max
percentage of glicole30%. Max working pressure 6bar. Max fluid temperature 60°C. Consisting of
 Inlet manifold complete with lockshield for the flow regulation
 Return manifold complete with flowmeter with graduated scale 1÷4l/min. Accuracy ±10%.
 Angle regulation lockshield with connection G3/4 male Eurokonus complete with no-return
valve. Inlet connection to boiler from right.
 Angle thermostatizable valve with connection G3/4 male Euroconus. Return connection to
boiler from right.
 Circulation pump 15-3 with permanent magnet, energy class A
 Contact security thermostat, regulation range 0 °C±90 °C. Protection grade IP20.
 Thermometer for the control of the inlet temperature to the radiant panel.
 Manual air drain valve and inlet-outlet water tap.
 Fixing device for the thermostatic probe.
CBP 4093
Article code:
CBP 4090
CBP 4091
CBP 4092
CBP 4093
Sede amministrativa, stabilimento e uffici commerciali – administrative office, factory and commercial office
via Madonnina, 94 – 25018 Montichiari - (BS) – Tel.: 030-9961161 – Fax: 030-9961165 – info@luxor.it – www.luxor.it
Pagina 12 di 12
Download