City of Regina Standard Construction Specification SECTION 02999 TRENCHLESS SEWER MAIN REPAIRS – Fiberglass Reinforced Epoxy 1.0 GENERAL 1.1 2.0 Work Included 1.1.1 Supply and installation of impregnated bi-directional woven fibreglass tissue with a predetermined epoxy resin. The impregnating tissue is rolled on a pneumatic tube (thermomandrel) corresponding in length with the length to be repaired. The thermomandrel will then be slipped inside the conduit (concrete, clay, brick, PVC, etc.) to repair using a nearby manhole. 1.1.2 Existing CCTV tapes, video logs and location plans of all spot repairs are available for review at the office of the Engineer. PRODUCTS 2.1 2.2 Materials include: 2.1.1 Balanced bi-directionally woven fiberglass tissue 2.1.2 Two Component epoxy resin as binding matrix General Physical Properties of the Fiberglass Tension Load Tension Modulus Thermal Expansion Coefficient Break Elongation Elastic Recovery 2.3 General Physical Properties of the Resin Tension Load Tension Modulus Flexion Load Flexion Modulus Elongation Barcol Hardness Thermal Expansion 2.4 3.4 x 103 MPa (493,000 psi) 72 x 103 MPa (10,442,000 psi) 2.8 x 10-6 po/po/°C 4.8% 100% ASTM D638 ASTM D638 ASTM D790 ASTM D790 ASTM 2583-81 ASTM D696 60 MPa (8,700 psi) 3.3 x 10 MPa (478,600 psi) 100 MPa (14,500 psi) 2.1 x 103 MPa (304,500 psi) 4.5% to 12% 50 -6 52 x 10 po/po/°C 3 Composite Material Tension Constraint Tension Modulus Flexion Constraint Flexion Modulus Hardness (Shore D) Latest Revision, August 2010 ASTM D638 ASTM D638 ASTM D790 ASTM D790 250 MPa (36,250 psi) 8.0 GPa (1,160,000 psi) 250 MPa (36,250 psi) 9.0 GPa (1,305,000 psi) > 80 Page 1 of 3 City of Regina Standard Construction Specification SECTION 02999 TRENCHLESS SEWER MAIN REPAIRS – Fiberglass Reinforced Epoxy 2.5 Chemical Resistance 2.5.1 2.6 Resin Mix 2.6.1 2.7 3.0 The bi-directional tissue layers shall overlap when wetted. Wall Thickness Design 2.8.1 2.9 Two component epoxydic resin mix controlled by volume. The homogenated mix shall be applied on the different layers of the bidirectional fiberglass tissue. The mixing and the wetting shall be made at the plant. Fiberglass Stratification 2.7.1 2.8 Resist sewer gas including carbon monoxide, dioxide, hydrogen sulphide etc. The fiberglass tissue shall not be affected by chemicals, bacteria, fungus or insects. The thickness shall be established by the Contractor, considering the size of the conduit to be lined. Submittals 2.9.1 Submit information on material, procedure, wall thickness for each line prior to installation. 2.9.2 Submit as-build data to the Engineer indicating locations of lines repaired following installation. 2.9.3 Submit a field sample for every 10 spot repairs completed. Longer spot repairs which are completed in multiple segments will be considered as one spot repair. Typically sample locations will be adjacent to manholes so the repair material can be confined and subject to the same curing as the adjacent spot repair. The City will bear the costs of testing. EXECUTION 3.1 Notification of Residents/Businesses 3.1.1 Latest Revision, August 2010 The Contractor is responsible for notification of residents/businesses of disruption of sewer service. Contractor must liase with residents/businesses during spot repairs and advise when normal service is restored. Provide alternative service to residents/businesses as required. Page 2 of 3 City of Regina Standard Construction Specification SECTION 02999 TRENCHLESS SEWER MAIN REPAIRS – Fiberglass Reinforced Epoxy 3.1.2 3.2 Conduits Cleaning 3.2.1 3.3 3.4 The manholes and the conduits shall be cleaned to remove roots, debris and other deposits that could cause problems during installation. Inspection 3.3.1 The section to be lined will be CCTV inspected before and after installation. 3.3.2 The laterals will be detected and thoroughly noted to minimize possible errors when reopening them after lining. 3.3.3 If the inspection reveals major defects, notify Engineer before remedial actions are undertaken. Laterals Opening 3.4.1 3.5 Traffic Accommodation: Follow all requirements as set out in the City of Regina’s Manual for Temporary Traffic Control. The laterals shall be reopened with a remote controlled robotic cutter for nonaccessible sewers. A CCTV camera shall be used to ascertain position. Installation 3.5.1 Clean existing line and complete a CCTV inspection prior to installation. A digital file shall be made of the CCTV inspection. 3.5.2 The flow of water shall be by-passed above ground till the closest possible other manhole if required. 3.5.3 The composite (fibreglass and resins) shall be prepared in a shop under a total quality control. On-site preparation will be acceptable based on onsite preparation facilities which meet the approval of the Engineer. 3.5.4 The wetted composite materials shall be transported to the jobsite and slipped into the conduit to be lined. 3.5.5 Cure with steam for a predetermined time based on diameter and length (between 45 and 90 minutes). 3.5.6 Cool and retrieve the thermomandrel to be reused for other insertions. 3.5.7 Open the lateral connections to reinstate service. 3.5.8 Provide CCTV inspection report and video after installation. Latest Revision, August 2010 Page 3 of 3