Coil Box Catalog-R-CB-102

advertisement
INSULATED COIL BOX DRAWINGS (continued)
Dual Circuit Intertwined DX Coil
with Insulated Housing and Drain Pan
Left Hand Airflow Shown
CD
1-1/2”
1-1/2”
=
=
=
=
=
Casing Depth
Fin Height
Fin Length
Overall Length
Fin Height + 5 3/16”
C O I L S
CD
FH
FL
OL
CH
6”
2-1/2”
REMOVABLE
ACCESS
FH
A/F
CH
A/F
LIQUID
2-1/2”
1” DRAIN COUPLING
1” ANGLE
DRAIN PAN
FLUSH WITH EDGE
w/ 1/2” SLOPE
OF SIDE PLATE
CAULK SEAMS
DRAIN PAN
SUPPORTS
12”
OL
FL
3-1/2”
Chilled or Hot Water Coil
with Insulated Housing and No Drain Pan
CD
FH
FL
OL
CH
Left Hand Airflow Shown
CD
1-1/2”
1-1/2”
Casing Depth
Fin Height
Fin Length
Overall Length
Fin Height + 5 3/16”
6”
INSULATION
2-1/2”
=
=
=
=
=
BOTTOM SIDE PLATE
REMOVABLE
ACCESS
CH
A/F
AS
SU
RANC
CU
FO R C E D C I R
NUFACTU
RE
MA
R
E
C
R
TOME
US
C O I L S
P.O. Box 1206, Pryor, OK 74362 • Phone 918-825-7222 • Fax 800-COIL FAX
R-CB-102
C
G
3-1/2”
AIR
LIN
OL
www. RAE-CORP .com
FL
R
A
6”
AI
•
COIL
SUPPORTS
TO AR
IA
S
YING WITH
PL
BOTTOM SIDE PLATE
N
OO
BOTTOM SIDE PLATE
T IO
LA
M
2-1/2”
IED
TIF
ER
O
C
C
RH
E AT
I S
T
I
ING CO
LS
AN DA RD
•
FH
0
A/F
4
1
Insulated
Coil Box
INSULATED COIL BOX
INSULATED COIL BOX DRAWINGS
Standard Box Construction
• 16-gage galvanized sheetmetal housing (unpainted)
• 1”/1 1/2 lbs. sq. ft. insulation open face
(not exposed to the air stream)
• Panel access to the headers and return bends
• 16-gage galvanized drain pan with mastic coating
(stainless steel drain pan is available as an option)
• 1” FPT drain coupling in drain pan
• Offset fin pack to maximize performance and drainage
• 1 1/2” duct flanges on entering and leaving airside of
coil housing
• 6” connection stub outs on all coil models
• Sloped drain pan
Row
Standard
Casing
Depth
1
2
3
4
6
8
10
CD with Drain Pan
15”
15”
18”
18”
20”
24”
28”
CD without Drain Pan
8”
8”
8”
10”
12”
16”
18”
Chilled or Hot Water Coil
with Insulated Housing and Drain Pan
CD
1-1/2”
2-1/2”
OUTLET
TOP
SIDE
PLATE
RETURN END
SIDE PANELS
HEADER END
SIDE PANELS
BOTTOM
SIDE PLATE
BAFFLE
DRAIN
PAN
CENTER
REMOVABLE
PANEL
BAFFLE
HEADER
BAFFLE
DRAIN
PAN
SUPPORTS
BOTTOM
OUTER
PANEL
FH
A/F
BOTTOM
REMOVABLE
PANEL
Standard delivery is four weeks after
the order is released for fabrication.
Options: Contact Factory
•
•
•
•
•
•
•
•
•
•
•
FH up to 72”
FL up to 180”
Intermediate Drain Pan
S.S. Drain Pan
Multiple Coils
Welded Steel Bases
Painted Boxes
Double Wall Construction
Mounted Filter Rack
Mounted TXVs
Mounted Hot Gas By-Pass
Connection
DRAIN PAN
2-1/2”
1” DRAIN COUPLING
DRAIN PAN
w/ 1/2” SLOPE
1” ANGLE
FLUSH WITH EDGE
OF SIDE PLATE
CAULK SEAMS
DRAIN
PAN
SUPPORTS
10”
FL
OL
3-1/2”
Single Circuited DX Coil
with Insulated Housing and Drain Pan
CD
FH
FL
OL
CH
Left Hand Airflow Shown
CD
1-1/2”
1-1/2”
=
=
=
=
=
Casing Depth
Fin Height
Fin Length
Overall Length
Fin Height + 5 3/16”
6”
STUB OUTS
2-1/2”
REMOVABLE
ACCESS
FH
A/F
CH
A/F
LIQUID
SUCTION
DRAIN PAN
2-1/2”
DRAIN PAN
w/ 1/2” SLOPE
1” DRAIN COUPLING
Products, Services, the Total Solution… visit us at
CH
A/F
INLET
Standard Delivery
TOP
REMOVABLE
PANEL
RETURN
BAFFLE
REMOVABLE
ACCESS
• Maximum of 500 FPM — up to 48” FH x 120” FL
with 8 FPI or less
• Maximum of 450 FPM — up to 48” FH x 120” FL
with 9 FPI or greater
The standard coil box design will accept either a blowthrough or draw-through application. The maximum static
pressure acceptable would be 2” w.g. positive or -1” w.g.
negative (measured on inlet side of coil). Localized areas
of higher velocities can cause water carry over and must
be avoided.
RETURN END
COVER
Casing Depth
Fin Height
Fin Length
Overall Length
Fin Height + 5 3/16”
6”
• Finned height = 12” to 48” in 1 1/2” increments
• Finned length = 12” to 128” in 1/2” increments
TOP
REMOVABLE
PANEL
1-1/2”
=
=
=
=
=
STUB OUTS
Standard Box Sizes Available
Recommendations: Face Velocities and
Static Pressure
CD
FH
FL
OL
CH
Left Hand Airflow Shown
www.rae-corp.com
1” ANGLE
FLUSH WITH EDGE
OF SIDE PLATE
CAULK SEAMS
10”
DRAIN
PAN
SUPPORTS
OL
FL
3-1/2”
INSULATED COIL BOX
INSULATED COIL BOX DRAWINGS
Standard Box Construction
• 16-gage galvanized sheetmetal housing (unpainted)
• 1”/1 1/2 lbs. sq. ft. insulation open face
(not exposed to the air stream)
• Panel access to the headers and return bends
• 16-gage galvanized drain pan with mastic coating
(stainless steel drain pan is available as an option)
• 1” FPT drain coupling in drain pan
• Offset fin pack to maximize performance and drainage
• 1 1/2” duct flanges on entering and leaving airside of
coil housing
• 6” connection stub outs on all coil models
• Sloped drain pan
Row
Standard
Casing
Depth
1
2
3
4
6
8
10
CD with Drain Pan
15”
15”
18”
18”
20”
24”
28”
CD without Drain Pan
8”
8”
8”
10”
12”
16”
18”
Chilled or Hot Water Coil
with Insulated Housing and Drain Pan
CD
1-1/2”
2-1/2”
OUTLET
TOP
SIDE
PLATE
RETURN END
SIDE PANELS
HEADER END
SIDE PANELS
BOTTOM
SIDE PLATE
BAFFLE
DRAIN
PAN
CENTER
REMOVABLE
PANEL
BAFFLE
HEADER
BAFFLE
DRAIN
PAN
SUPPORTS
BOTTOM
OUTER
PANEL
FH
A/F
BOTTOM
REMOVABLE
PANEL
Standard delivery is four weeks after
the order is released for fabrication.
Options: Contact Factory
•
•
•
•
•
•
•
•
•
•
•
FH up to 72”
FL up to 180”
Intermediate Drain Pan
S.S. Drain Pan
Multiple Coils
Welded Steel Bases
Painted Boxes
Double Wall Construction
Mounted Filter Rack
Mounted TXVs
Mounted Hot Gas By-Pass
Connection
DRAIN PAN
2-1/2”
1” DRAIN COUPLING
DRAIN PAN
w/ 1/2” SLOPE
1” ANGLE
FLUSH WITH EDGE
OF SIDE PLATE
CAULK SEAMS
DRAIN
PAN
SUPPORTS
10”
FL
OL
3-1/2”
Single Circuited DX Coil
with Insulated Housing and Drain Pan
CD
FH
FL
OL
CH
Left Hand Airflow Shown
CD
1-1/2”
1-1/2”
=
=
=
=
=
Casing Depth
Fin Height
Fin Length
Overall Length
Fin Height + 5 3/16”
6”
STUB OUTS
2-1/2”
REMOVABLE
ACCESS
FH
A/F
CH
A/F
LIQUID
SUCTION
DRAIN PAN
2-1/2”
DRAIN PAN
w/ 1/2” SLOPE
1” DRAIN COUPLING
Products, Services, the Total Solution… visit us at
CH
A/F
INLET
Standard Delivery
TOP
REMOVABLE
PANEL
RETURN
BAFFLE
REMOVABLE
ACCESS
• Maximum of 500 FPM — up to 48” FH x 120” FL
with 8 FPI or less
• Maximum of 450 FPM — up to 48” FH x 120” FL
with 9 FPI or greater
The standard coil box design will accept either a blowthrough or draw-through application. The maximum static
pressure acceptable would be 2” w.g. positive or -1” w.g.
negative (measured on inlet side of coil). Localized areas
of higher velocities can cause water carry over and must
be avoided.
RETURN END
COVER
Casing Depth
Fin Height
Fin Length
Overall Length
Fin Height + 5 3/16”
6”
• Finned height = 12” to 48” in 1 1/2” increments
• Finned length = 12” to 128” in 1/2” increments
TOP
REMOVABLE
PANEL
1-1/2”
=
=
=
=
=
STUB OUTS
Standard Box Sizes Available
Recommendations: Face Velocities and
Static Pressure
CD
FH
FL
OL
CH
Left Hand Airflow Shown
www.rae-corp.com
1” ANGLE
FLUSH WITH EDGE
OF SIDE PLATE
CAULK SEAMS
10”
DRAIN
PAN
SUPPORTS
OL
FL
3-1/2”
INSULATED COIL BOX DRAWINGS (continued)
Dual Circuit Intertwined DX Coil
with Insulated Housing and Drain Pan
Left Hand Airflow Shown
CD
1-1/2”
1-1/2”
=
=
=
=
=
Casing Depth
Fin Height
Fin Length
Overall Length
Fin Height + 5 3/16”
C O I L S
CD
FH
FL
OL
CH
6”
2-1/2”
REMOVABLE
ACCESS
FH
A/F
CH
A/F
LIQUID
2-1/2”
1” DRAIN COUPLING
1” ANGLE
DRAIN PAN
FLUSH WITH EDGE
w/ 1/2” SLOPE
OF SIDE PLATE
CAULK SEAMS
DRAIN PAN
SUPPORTS
12”
OL
FL
3-1/2”
Chilled or Hot Water Coil
with Insulated Housing and No Drain Pan
CD
FH
FL
OL
CH
Left Hand Airflow Shown
CD
1-1/2”
1-1/2”
Casing Depth
Fin Height
Fin Length
Overall Length
Fin Height + 5 3/16”
6”
INSULATION
2-1/2”
=
=
=
=
=
BOTTOM SIDE PLATE
REMOVABLE
ACCESS
CH
A/F
AS
SU
RANC
CU
FO R C E D C I R
NUFACTU
RE
MA
R
E
C
R
TOME
US
C O I L S
P.O. Box 1206, Pryor, OK 74362 • Phone 918-825-7222 • Fax 800-COIL FAX
R-CB-102
C
G
3-1/2”
AIR
LIN
OL
www. RAE-CORP .com
FL
R
A
6”
AI
•
COIL
SUPPORTS
TO AR
IA
S
YING WITH
PL
BOTTOM SIDE PLATE
N
OO
BOTTOM SIDE PLATE
T IO
LA
M
2-1/2”
IED
TIF
ER
O
C
C
RH
E AT
I S
T
I
ING CO
LS
AN DA RD
•
FH
0
A/F
4
1
Insulated
Coil Box
Download