Building wire provides the diversified wiring solution today for various industrial and residential applications. Taihan offers a complete line of building wire to meet the requirements of the electrical industry. Contents 04 ANNEALED COPPER CONDUCTOR 06 TFFN Type 08 THW Type 10 THHN/THWN Type 12 XHHW-2 Type 14 USE-2/RHH/RHW-2 Type 16 URD, Duplex Type 18 URD, Triplex Type 20 URD, Quadruplex Type 22 TC CONTROL CABLE Type 24 TC POWER CABLE Type (THHN-THWN Type) 26 TC POWER CABLE Type (XHHW-2 Type) Building wire provides the diversified wiring solution today for various industrial and residential applications. Taihan offers a complete line of building wire to meet the requirements of the electrical industry. Contents 04 ANNEALED COPPER CONDUCTOR 06 TFFN Type 08 THW Type 10 THHN/THWN Type 12 XHHW-2 Type 14 USE-2/RHH/RHW-2 Type 16 URD, Duplex Type 18 URD, Triplex Type 20 URD, Quadruplex Type 22 TC CONTROL CABLE Type 24 TC POWER CABLE Type (THHN-THWN Type) 26 TC POWER CABLE Type (XHHW-2 Type) ANNEALED COPPER CONDUCTOR Annealed Copper Conductor Solid and Stranded This copper conductor is generally used for equipment and circuit grounding. Soft-drawn bare annealed copper APPLICATION STANDARDS General purpose for equipment and circuit grounding ASTM B-3 : Soft-drawn-annealed copper wire ASTM B-8 : Concentric-lay-stranded copper conductors ASTM B-787 : 19 wire combination unilay-stranded copper conductors PRODUCT CONSTRUCTION Conductor Soft-drawn bare annealed copper Building Wire 04 Conductor Size AWG/MCM No. of Strands Nominal Outer Diameter Copper Weight inches lbs/mft 14 Solid 0.064 12.4 12 Solid 0.081 19.8 10 Solid 0.102 31.4 8 Solid 0.129 50.0 8 7 0.146 51.0 6 Solid 0.162 79.4 Packaging 6 7 0.184 81.1 Master cutting lengths on non-returnable wooden reels 4 Solid 0.204 126.3 4 7 0.232 128.9 2 Solid 0.258 200.9 2 7 0.292 204.9 1 7 0.328 258.4 1/0 7 0.368 326.0 1/0 19 0.373 326.0 2/0 7 0.414 411.0 2/0 19 0.419 411.0 3/0 7 0.464 518.1 3/0 19 0.470 518.1 4/0 7 0.522 653.3 4/0 19 0.528 653.3 250 37 0.575 771.9 350 37 0.681 1,081.0 500 37 0.813 1,544.0 750 61 0.998 2,316.0 1,000 61 1.152 3,088.0 05 Building Wire ANNEALED COPPER CONDUCTOR Annealed Copper Conductor Solid and Stranded This copper conductor is generally used for equipment and circuit grounding. Soft-drawn bare annealed copper APPLICATION STANDARDS General purpose for equipment and circuit grounding ASTM B-3 : Soft-drawn-annealed copper wire ASTM B-8 : Concentric-lay-stranded copper conductors ASTM B-787 : 19 wire combination unilay-stranded copper conductors PRODUCT CONSTRUCTION Conductor Soft-drawn bare annealed copper Building Wire 04 Conductor Size AWG/MCM No. of Strands Nominal Outer Diameter Copper Weight inches lbs/mft 14 Solid 0.064 12.4 12 Solid 0.081 19.8 10 Solid 0.102 31.4 8 Solid 0.129 50.0 8 7 0.146 51.0 6 Solid 0.162 79.4 Packaging 6 7 0.184 81.1 Master cutting lengths on non-returnable wooden reels 4 Solid 0.204 126.3 4 7 0.232 128.9 2 Solid 0.258 200.9 2 7 0.292 204.9 1 7 0.328 258.4 1/0 7 0.368 326.0 1/0 19 0.373 326.0 2/0 7 0.414 411.0 2/0 19 0.419 411.0 3/0 7 0.464 518.1 3/0 19 0.470 518.1 4/0 7 0.522 653.3 4/0 19 0.528 653.3 250 37 0.575 771.9 350 37 0.681 1,081.0 500 37 0.813 1,544.0 750 61 0.998 2,316.0 1,000 61 1.152 3,088.0 05 Building Wire TFFN TYPE 600V TFFN PVC Insulation and Nylon Jacket, 600 Volts, 90°C For commercial and industrial projects, TFFN is widely used for power distribution. From service entrance and feeders to branch circuits, it can handle electrical wiring needs most properly. Bunch Stranded Copper Conductor PVC Insulation Nylon Jacket APPLICATION STANDARDS PRODUCT CONSTRUCTION Applied for internal wiring of fixtures insulated with polyvinyl chloride(PVC) and covered with protective sheath of nylon intended for fixture raceways and fire alarm circuits wiring as specified in the National Electrical Code. The wire may be operated at 90℃ maximum continuous temperature in dry location. ASTM B-3 and B-174 UL Standard 62 for fixture wire UL Standard 1063 for machine tool wire Conductor Bare annealed bunch stranded conductor Insulation Flame-retardant, heat, abrasion and moisture-resistant PVC with polyamide nylon Identification Color Black, White, Red, Green, Yellow, Blue, Orange, Gray, Purple, Pink Print Legend E57237 (UL) SIZE 600V TYPE TFFN OR GASOLINE AND OIL RESISTANT Ⅱ VW-1 Packaging 4×500、in a carton 2500、reels Conductor Size Building Wire 06 Diameter Insulation Thickness Jacket Thickness Approx. Overall Diameter Approx. Weight AWG mm2 No. of Strands mm mils mm mils mm mils mm mils kg/km lbs/1000ft 18 0.811 16/0.254 1.17 46.1 0.38 15 0.1 4 2.23 87.8 11.2 7.5 16 1.31 26/0.254 1.49 58.7 0.38 15 0.1 4 2.55 100.8 16.5 11.1 07 Building Wire TFFN TYPE 600V TFFN PVC Insulation and Nylon Jacket, 600 Volts, 90°C For commercial and industrial projects, TFFN is widely used for power distribution. From service entrance and feeders to branch circuits, it can handle electrical wiring needs most properly. Bunch Stranded Copper Conductor PVC Insulation Nylon Jacket APPLICATION STANDARDS PRODUCT CONSTRUCTION Applied for internal wiring of fixtures insulated with polyvinyl chloride(PVC) and covered with protective sheath of nylon intended for fixture raceways and fire alarm circuits wiring as specified in the National Electrical Code. The wire may be operated at 90℃ maximum continuous temperature in dry location. ASTM B-3 and B-174 UL Standard 62 for fixture wire UL Standard 1063 for machine tool wire Conductor Bare annealed bunch stranded conductor Insulation Flame-retardant, heat, abrasion and moisture-resistant PVC with polyamide nylon Identification Color Black, White, Red, Green, Yellow, Blue, Orange, Gray, Purple, Pink Print Legend E57237 (UL) SIZE 600V TYPE TFFN OR GASOLINE AND OIL RESISTANT Ⅱ VW-1 Packaging 4×500、in a carton 2500、reels Conductor Size Building Wire 06 Diameter Insulation Thickness Jacket Thickness Approx. Overall Diameter Approx. Weight AWG mm2 No. of Strands mm mils mm mils mm mils mm mils kg/km lbs/1000ft 18 0.811 16/0.254 1.17 46.1 0.38 15 0.1 4 2.23 87.8 11.2 7.5 16 1.31 26/0.254 1.49 58.7 0.38 15 0.1 4 2.55 100.8 16.5 11.1 07 Building Wire THW TYPE 600V THW PVC Insulation, 600 Volts, 75°C THW is used for general purpose of wiring in residential, commercial and industrial installations. Copper Conductor Heat-resistant PVC Insulation APPLICATION STANDARD Generally used for wiring for the supply of electrical power of residential, commercial, industrial buildings in accordance with the National Electrical Code, maximum continuous conductor temperature of 75℃ in wet or dry locations. UL 83 : Thermoplastic insulated wires and cables Conductor Size PRODUCT CONSTRUCTION AWG or MCM mm2 No. of Strands Diameter mm mils Insulation Thickness mm Approx. Overall Diameter mils mm mils Approx. Weight Standard Length � Ampacity kg/km lbs/ 1000ft Dry & Wet m ft Conductor 14 2.08 1 1.63 64.1 0.76 30 3.2 126 27 18 15 915 3,000 Bare annealed solid or stranded conductor 14 2.08 7 1.85 72.7 0.76 30 3.5 138 29 19 15 915 3,000 12 3.31 1 2.05 80.8 0.76 30 3.7 146 39 26 20 915 3,000 12 3.31 7 2.32 91.5 0.76 30 3.9 155 42 28 20 915 3,000 10 5.26 1 2.588 101.9 0.76 30 4.2 165 59 40 30 915 3,000 10 5.26 7 2.95 116 0.76 30 4.5 178 62 42 30 915 3,000 Insulation Abrasion, moisture, and heat-resistant PVC(Polyvinyl chloride) Identification Color 8 7 3.71 146 1.14 45 6.1 240 104 70 50 915 3,000 Black, White, Red, Green, Yellow, Brown, Blue, Orange, Gray, Purple, Pink 6 13.3 7 4.67 184 1.52 60 7.9 310 169 114 65 915 3,000 4 21.2 7 5.89 232 1.52 60 9.1 357 250 168 85 915 3,000 Print Legend 3 26.7 7 6.60 260 1.52 60 9.8 386 306 206 100 915 3,000 E96723 (UL) SIZE 600V THW VW-1 (14AWG~1AWG) E96723 (UL) SIZE 600V THW OR SUNLIGHT RESISTANT VW-1 (1/0AWG and larger) 2 33.6 7 7.42 292 1.52 60 10.6 418 377 253 115 915 3,000 1 42.4 19 8.43 332 2.03 80 12.7 501 492 331 130 457 1,500 1/0 53.5 19 9.45 372 2.03 80 13.7 539 600 403 150 457 1,500 2/0 67.4 19 10.62 418 2.03 80 14.9 587 744 500 175 457 1,500 85.0 3/0 8.37 19 11.94 470 2.03 80 16.2 638 917 616 200 457 1,500 4/0 107 19 13.41 528 2.03 80 17.7 697 1,133 761 230 457 1,500 250 127 37 14.61 575 2.41 95 19.7 776 1,357 912 255 457 1,500 300 152 37 16.00 630 2.41 95 21.1 831 1,606 1,079 285 457 1,500 350 177 37 17.30 681 2.41 95 22.4 882 1,849 1,242 310 457 1,500 400 203 37 18.49 728 2.41 95 23.6 929 2,094 1,407 335 457 1,500 500 253 37 20.65 813 2.41 95 25.7 1,012 2,580 1,734 380 305 1,000 600 304 61 22.68 893 2.79 110 28.6 1,126 3,126 2,101 420 305 1,000 750 380 61 25.35 998 2.79 110 31.3 1,232 3,866 2,598 475 305 1,000 1,000 507 61 29.26 1,152 2.79 110 35.1 1,382 5,065 3,404 545 305 1,000 � : Per Table 310-16 of the National Electrical Code, 1996 edition. Conditions : Not more than three conductors in raceway or cable or earth(directly buried), based on ambient temperature of 30℃. Building Wire 08 09 Building Wire THW TYPE 600V THW PVC Insulation, 600 Volts, 75°C THW is used for general purpose of wiring in residential, commercial and industrial installations. Copper Conductor Heat-resistant PVC Insulation APPLICATION STANDARD Generally used for wiring for the supply of electrical power of residential, commercial, industrial buildings in accordance with the National Electrical Code, maximum continuous conductor temperature of 75℃ in wet or dry locations. UL 83 : Thermoplastic insulated wires and cables Conductor Size PRODUCT CONSTRUCTION AWG or MCM mm2 No. of Strands Diameter mm mils Insulation Thickness mm Approx. Overall Diameter mils mm mils Approx. Weight Standard Length � Ampacity kg/km lbs/ 1000ft Dry & Wet m ft Conductor 14 2.08 1 1.63 64.1 0.76 30 3.2 126 27 18 15 915 3,000 Bare annealed solid or stranded conductor 14 2.08 7 1.85 72.7 0.76 30 3.5 138 29 19 15 915 3,000 12 3.31 1 2.05 80.8 0.76 30 3.7 146 39 26 20 915 3,000 12 3.31 7 2.32 91.5 0.76 30 3.9 155 42 28 20 915 3,000 10 5.26 1 2.588 101.9 0.76 30 4.2 165 59 40 30 915 3,000 10 5.26 7 2.95 116 0.76 30 4.5 178 62 42 30 915 3,000 Insulation Abrasion, moisture, and heat-resistant PVC(Polyvinyl chloride) Identification Color 8 7 3.71 146 1.14 45 6.1 240 104 70 50 915 3,000 Black, White, Red, Green, Yellow, Brown, Blue, Orange, Gray, Purple, Pink 6 13.3 7 4.67 184 1.52 60 7.9 310 169 114 65 915 3,000 4 21.2 7 5.89 232 1.52 60 9.1 357 250 168 85 915 3,000 Print Legend 3 26.7 7 6.60 260 1.52 60 9.8 386 306 206 100 915 3,000 E96723 (UL) SIZE 600V THW VW-1 (14AWG~1AWG) E96723 (UL) SIZE 600V THW OR SUNLIGHT RESISTANT VW-1 (1/0AWG and larger) 2 33.6 7 7.42 292 1.52 60 10.6 418 377 253 115 915 3,000 1 42.4 19 8.43 332 2.03 80 12.7 501 492 331 130 457 1,500 1/0 53.5 19 9.45 372 2.03 80 13.7 539 600 403 150 457 1,500 2/0 67.4 19 10.62 418 2.03 80 14.9 587 744 500 175 457 1,500 85.0 3/0 8.37 19 11.94 470 2.03 80 16.2 638 917 616 200 457 1,500 4/0 107 19 13.41 528 2.03 80 17.7 697 1,133 761 230 457 1,500 250 127 37 14.61 575 2.41 95 19.7 776 1,357 912 255 457 1,500 300 152 37 16.00 630 2.41 95 21.1 831 1,606 1,079 285 457 1,500 350 177 37 17.30 681 2.41 95 22.4 882 1,849 1,242 310 457 1,500 400 203 37 18.49 728 2.41 95 23.6 929 2,094 1,407 335 457 1,500 500 253 37 20.65 813 2.41 95 25.7 1,012 2,580 1,734 380 305 1,000 600 304 61 22.68 893 2.79 110 28.6 1,126 3,126 2,101 420 305 1,000 750 380 61 25.35 998 2.79 110 31.3 1,232 3,866 2,598 475 305 1,000 1,000 507 61 29.26 1,152 2.79 110 35.1 1,382 5,065 3,404 545 305 1,000 � : Per Table 310-16 of the National Electrical Code, 1996 edition. Conditions : Not more than three conductors in raceway or cable or earth(directly buried), based on ambient temperature of 30℃. Building Wire 08 09 Building Wire THHN / THWN TYPE 600V THHN / THWN PVC Insulation and Nylon Jacket, 600 Volts, 90°C Dry, 75°C Wet For commercial and industrial projects, THHN/THWN is widely used for power distribution. From service entrance and feeders to branch circuits, it can handle electrical wiring needs most properly . Copper Conductor PVC Insulation Nylon Jacket APPLICATION PRODUCT CONSTRUCTION General purpose for building wiring insulated with polyvinyl chloride(PVC) and covered with a tough protective sheath of nylon intended for lighting and power circuits wiring as specified in the National Electrical Code. The wire may be operated at 90℃ maximum continuous temperature in dry locations and in wet locations. Conductor STANDARDS UL 83 : Thermoplastic insulated wires and cables TYPE THHN : 90℃ dry TYPE THWN : 75℃ wet or dry Conductor Bare annealed solid or stranded conductor Insulation Flame-retardant, heat, abrasion and moisture-resistant PVC with polyamide nylon Size AWG or MCM Identification Color Black, White, Red, Green, Yellow, Blue, Orange, Gray, Purple, Pink Print Legend mm 1.63 mils 64.1 Approx. Overall Diameter mm mils mm mils mm 0.38 15 0.1 4 2.7 mils 106 Approx. Weight �Ampacity kg/km lbs/ 1000ft THWN (75˚C) THHN (90˚C) 24 16 15 15 14 2.08 1 14 2.08 19 1.85 72.7 0.38 15 0.1 4 2.9 114 24 16 15 15 12 3.31 1 2.05 80.8 0.38 15 0.1 4 3.2 126 36 24 20 20 12 3.31 19 2.32 91.5 0.38 15 0.1 4 3.4 134 37 25 20 20 10 5.26 1 2.588 101.9 0.51 20 0.1 4 3.9 154 57 38 30 30 10 5.26 19 2.95 116 0.51 20 0.1 4 4.3 169 58 39 30 30 8 8.37 1 3.264 128.5 0.76 30 0.13 5 5.3 209 91 61 50 55 8 8.37 19 3.71 146 0.76 30 0.13 5 5.6 220 98 66 50 55 6 13.3 19 4.67 184 0.76 30 0.13 5 6.6 260 146 98 65 75 14AWG through 1AWG stranded : E109010 (UL) SIZE 600V TYPE MTW OR THHN OR THWN OR GASOLINE AND OIL RESISTANT Ⅱ VW-1 OR AWM 4 21.2 19 5.89 232 1.02 40 0.15 6 8.9 350 237 159 85 95 2 33.6 19 6.60 260 1.02 40 0.15 6 10.0 394 357 240 115 130 1 42.4 19 8.43 332 1.27 50 0.18 7 11.4 449 455 306 130 150 1/0 42.4 19 9.45 372 1.27 50 0.18 7 12.5 492 558 375 150 170 2/0 67.4 19 10.62 418 1.27 50 0.18 7 13.6 535 696 468 175 195 3/0 85.0 19 11.94 470 1.27 50 0.18 7 14.8 583 865 581 200 225 1/0 AWG and larger : E109010 (UL) SIZE 600V TYPE MTW OR THHN OR THWN OR GASOLINE AND OIL RESISTANT Ⅱ SUNLIGHT RESISTANT VW-1 OR AWM 4/0 107 19 13.41 528 1.27 50 0.18 7 16.2 638 1,071 720 230 260 250 127 37 14.61 575 1.52 60 0.2 8 18.0 709 1,280 860 255 290 Packaging 300 152 37 16.00 630 1.52 60 0.2 8 19.3 760 1,518 1,020 285 320 350 177 37 17.30 681 1.52 60 0.2 8 20.6 811 1,759 1,182 310 350 400 203 37 18.49 728 1.52 60 0.2 8 21.7 854 1,994 1,340 335 380 500 253 37 20.65 813 1.52 60 0.2 8 23.9 941 2,470 1,660 380 430 � 10 No. of Strands Jacket Thickness 14AWG through 10AWG solid : E96723 (UL) SIZE 600V THHN OR THWN OR GASOLINE AND OIL RESISTANT Ⅱ VW-1 OR AWM 14AWG and 12AWG : 4×500′in a carton, or 2500′reel 10AWG : 2×500′in a carton or 2500′reel 8AWG through 2AWG : 500′, 1000′, 2500′reel, and cut to order 1AWG and larger : cut to order Building Wire mm2 Insulation Thickness Diameter 750 380 61 25.35 998 1.78 70 0.23 9 28.9 1,138 3,706 2,490 475 535 1,000 507 61 29.26 1,152 1.78 70 0.23 9 32.7 1,289 4,821 3,240 545 615 : Per Table 310-16 of the National Electrical Code, 1996 edition. Conditions : Not more than three conductors in raceway or cable or earth(directly buried), based on ambient temperature of 30℃. 11 Building Wire THHN / THWN TYPE 600V THHN / THWN PVC Insulation and Nylon Jacket, 600 Volts, 90°C Dry, 75°C Wet For commercial and industrial projects, THHN/THWN is widely used for power distribution. From service entrance and feeders to branch circuits, it can handle electrical wiring needs most properly . Copper Conductor PVC Insulation Nylon Jacket APPLICATION PRODUCT CONSTRUCTION General purpose for building wiring insulated with polyvinyl chloride(PVC) and covered with a tough protective sheath of nylon intended for lighting and power circuits wiring as specified in the National Electrical Code. The wire may be operated at 90℃ maximum continuous temperature in dry locations and in wet locations. Conductor STANDARDS UL 83 : Thermoplastic insulated wires and cables TYPE THHN : 90℃ dry TYPE THWN : 75℃ wet or dry Conductor Bare annealed solid or stranded conductor Insulation Flame-retardant, heat, abrasion and moisture-resistant PVC with polyamide nylon Size AWG or MCM Identification Color Black, White, Red, Green, Yellow, Blue, Orange, Gray, Purple, Pink Print Legend mm 1.63 mils 64.1 Approx. Overall Diameter mm mils mm mils mm 0.38 15 0.1 4 2.7 mils 106 Approx. Weight �Ampacity kg/km lbs/ 1000ft THWN (75˚C) THHN (90˚C) 24 16 15 15 14 2.08 1 14 2.08 19 1.85 72.7 0.38 15 0.1 4 2.9 114 24 16 15 15 12 3.31 1 2.05 80.8 0.38 15 0.1 4 3.2 126 36 24 20 20 12 3.31 19 2.32 91.5 0.38 15 0.1 4 3.4 134 37 25 20 20 10 5.26 1 2.588 101.9 0.51 20 0.1 4 3.9 154 57 38 30 30 10 5.26 19 2.95 116 0.51 20 0.1 4 4.3 169 58 39 30 30 8 8.37 1 3.264 128.5 0.76 30 0.13 5 5.3 209 91 61 50 55 8 8.37 19 3.71 146 0.76 30 0.13 5 5.6 220 98 66 50 55 6 13.3 19 4.67 184 0.76 30 0.13 5 6.6 260 146 98 65 75 14AWG through 1AWG stranded : E109010 (UL) SIZE 600V TYPE MTW OR THHN OR THWN OR GASOLINE AND OIL RESISTANT Ⅱ VW-1 OR AWM 4 21.2 19 5.89 232 1.02 40 0.15 6 8.9 350 237 159 85 95 2 33.6 19 6.60 260 1.02 40 0.15 6 10.0 394 357 240 115 130 1 42.4 19 8.43 332 1.27 50 0.18 7 11.4 449 455 306 130 150 1/0 42.4 19 9.45 372 1.27 50 0.18 7 12.5 492 558 375 150 170 2/0 67.4 19 10.62 418 1.27 50 0.18 7 13.6 535 696 468 175 195 3/0 85.0 19 11.94 470 1.27 50 0.18 7 14.8 583 865 581 200 225 1/0 AWG and larger : E109010 (UL) SIZE 600V TYPE MTW OR THHN OR THWN OR GASOLINE AND OIL RESISTANT Ⅱ SUNLIGHT RESISTANT VW-1 OR AWM 4/0 107 19 13.41 528 1.27 50 0.18 7 16.2 638 1,071 720 230 260 250 127 37 14.61 575 1.52 60 0.2 8 18.0 709 1,280 860 255 290 Packaging 300 152 37 16.00 630 1.52 60 0.2 8 19.3 760 1,518 1,020 285 320 350 177 37 17.30 681 1.52 60 0.2 8 20.6 811 1,759 1,182 310 350 400 203 37 18.49 728 1.52 60 0.2 8 21.7 854 1,994 1,340 335 380 500 253 37 20.65 813 1.52 60 0.2 8 23.9 941 2,470 1,660 380 430 � 10 No. of Strands Jacket Thickness 14AWG through 10AWG solid : E96723 (UL) SIZE 600V THHN OR THWN OR GASOLINE AND OIL RESISTANT Ⅱ VW-1 OR AWM 14AWG and 12AWG : 4×500′in a carton, or 2500′reel 10AWG : 2×500′in a carton or 2500′reel 8AWG through 2AWG : 500′, 1000′, 2500′reel, and cut to order 1AWG and larger : cut to order Building Wire mm2 Insulation Thickness Diameter 750 380 61 25.35 998 1.78 70 0.23 9 28.9 1,138 3,706 2,490 475 535 1,000 507 61 29.26 1,152 1.78 70 0.23 9 32.7 1,289 4,821 3,240 545 615 : Per Table 310-16 of the National Electrical Code, 1996 edition. Conditions : Not more than three conductors in raceway or cable or earth(directly buried), based on ambient temperature of 30℃. 11 Building Wire XHHW-2 TYPE 600V XHHW-2 XLPE Insulation, 600 Volts, 90°C Wet or Dry XLPE insulated XHHW-2 is an ideal wiring solution. Type XHHW-2 is well suited for building wire for power distribution. It offers excellent dielectric, tensile strength and cut resistance properties. Copper Conductor XLPE Insulation APPLICATION PRODUCT CONSTRUCTION General purpose for building wiring insulated with crosslinked polyethylene(XLPE) for lighting and power circuit wiring as specified in the National Electrical Code. The wire may be operated at 90℃ maximum continuous conductor temperature in wet or dry locations. Conductor Conductor Conductors shall be class B stranded annealed bare conductor Size AWG or MCM Insulation XLPE(cross-linked polyethylene) Abrasion, heat and moisture resistant mm 2 Insulation Thickness ��Diameter No. of Strands mm mils mm mils Approx. Overall Diameter mm mils Approx. Weight kg/km lbs/ 1000ft � Ampacity 14 2.08 1 1.63 64.1 0.76 30 3.3 132 25 17 15 14 2.08 7 1.85 72.7 0.76 30 3.5 140 25 17 15 12 3.31 1 2.05 80.8 0.76 30 3.7 148 35 24 20 STANDARD Identification Color 12 3.31 7 2.32 0.76 30 4.0 160 40 27 20 5.26 1 2.588 102 0.76 30 4.2 168 55 37 30 UL 44 : Thermoplastic insulated wires and cables Black, White, Red, Green, Yellow, Brown, Blue, Orange, Gray 10 10 5.26 7 2.95 116 0.76 30 4.5 180 60 40 30 8 8.37 1 3.264 129 1.14 45 5.7 228 95 64 55 8.37 91.5 Print Legend 8 7 3.71 146 1.14 45 6.2 248 100 67 55 E113293 (UL) SIZE 600V TYPE XHHW-2 6 13.3 7 4.67 184 1.14 45 7.1 284 150 100 75 4 21.2 7 5.89 232 1.14 45 8.3 332 220 150 95 3 26.7 7 6.60 260 1.14 45 9.1 364 280 190 110 2 33.6 7 7.42 292 1.14 45 9.9 396 350 240 130 1 42.4 19 8.43 332 1.40 55 11.5 460 440 300 150 1/0 53.5 19 9.45 372 1.40 55 12.5 500 550 370 170 2/0 67.4 19 10.62 418 1.40 55 13.7 548 690 460 195 85.0 Packaging 14AWG and 12AWG : 2×500′in a carton, or 2500′reel 10AWG : 1×500′in a carton, or 2500′reel 8AWG and larger : cut to order 3/0 19 11.94 470 1.40 55 15.0 600 850 570 225 4/0 107 19 13.41 528 1.40 55 16.4 656 1,060 710 260 250 127 37 14.61 575 1.65 65 18.3 732 1,270 850 290 300 152 37 16.00 630 1.65 65 19.8 792 1,520 1,020 320 350 177 37 17.30 681 1.65 65 21.0 840 1,750 1,180 350 400 203 37 18.49 728 1.65 65 22.2 888 1,990 1,340 380 500 253 37 20.65 813 1.65 65 24.3 972 2,470 1,660 430 600 304 61 22.68 893 2.03 80 27.3 1,092 3,000 2,020 475 750 380 61 25.35 998 2.03 80 30.0 1,200 3,730 2,510 535 1,000 507 61 29.26 1,152 2.03 80 33.9 1,356 4,900 3,290 615 : Per Table 310-16 of the National Electrical Code, 1996 edition. Conditions : Not more than three conductors in raceway or cable or earth(directly buried), based on ambient temperature of 30℃. �� : These values are the outer diameter of the solid or concentric stranded class B conductor. For stranded conductor, the compress stranding may be available to reduce the conductor diameter. � Building Wire 12 13 Building Wire XHHW-2 TYPE 600V XHHW-2 XLPE Insulation, 600 Volts, 90°C Wet or Dry XLPE insulated XHHW-2 is an ideal wiring solution. Type XHHW-2 is well suited for building wire for power distribution. It offers excellent dielectric, tensile strength and cut resistance properties. Copper Conductor XLPE Insulation APPLICATION PRODUCT CONSTRUCTION General purpose for building wiring insulated with crosslinked polyethylene(XLPE) for lighting and power circuit wiring as specified in the National Electrical Code. The wire may be operated at 90℃ maximum continuous conductor temperature in wet or dry locations. Conductor Conductor Conductors shall be class B stranded annealed bare conductor Size AWG or MCM Insulation XLPE(cross-linked polyethylene) Abrasion, heat and moisture resistant mm 2 Insulation Thickness ��Diameter No. of Strands mm mils mm mils Approx. Overall Diameter mm mils Approx. Weight kg/km lbs/ 1000ft � Ampacity 14 2.08 1 1.63 64.1 0.76 30 3.3 132 25 17 15 14 2.08 7 1.85 72.7 0.76 30 3.5 140 25 17 15 12 3.31 1 2.05 80.8 0.76 30 3.7 148 35 24 20 STANDARD Identification Color 12 3.31 7 2.32 0.76 30 4.0 160 40 27 20 5.26 1 2.588 102 0.76 30 4.2 168 55 37 30 UL 44 : Thermoplastic insulated wires and cables Black, White, Red, Green, Yellow, Brown, Blue, Orange, Gray 10 10 5.26 7 2.95 116 0.76 30 4.5 180 60 40 30 8 8.37 1 3.264 129 1.14 45 5.7 228 95 64 55 8.37 91.5 Print Legend 8 7 3.71 146 1.14 45 6.2 248 100 67 55 E113293 (UL) SIZE 600V TYPE XHHW-2 6 13.3 7 4.67 184 1.14 45 7.1 284 150 100 75 4 21.2 7 5.89 232 1.14 45 8.3 332 220 150 95 3 26.7 7 6.60 260 1.14 45 9.1 364 280 190 110 2 33.6 7 7.42 292 1.14 45 9.9 396 350 240 130 1 42.4 19 8.43 332 1.40 55 11.5 460 440 300 150 1/0 53.5 19 9.45 372 1.40 55 12.5 500 550 370 170 2/0 67.4 19 10.62 418 1.40 55 13.7 548 690 460 195 85.0 Packaging 14AWG and 12AWG : 2×500′in a carton, or 2500′reel 10AWG : 1×500′in a carton, or 2500′reel 8AWG and larger : cut to order 3/0 19 11.94 470 1.40 55 15.0 600 850 570 225 4/0 107 19 13.41 528 1.40 55 16.4 656 1,060 710 260 250 127 37 14.61 575 1.65 65 18.3 732 1,270 850 290 300 152 37 16.00 630 1.65 65 19.8 792 1,520 1,020 320 350 177 37 17.30 681 1.65 65 21.0 840 1,750 1,180 350 400 203 37 18.49 728 1.65 65 22.2 888 1,990 1,340 380 500 253 37 20.65 813 1.65 65 24.3 972 2,470 1,660 430 600 304 61 22.68 893 2.03 80 27.3 1,092 3,000 2,020 475 750 380 61 25.35 998 2.03 80 30.0 1,200 3,730 2,510 535 1,000 507 61 29.26 1,152 2.03 80 33.9 1,356 4,900 3,290 615 : Per Table 310-16 of the National Electrical Code, 1996 edition. Conditions : Not more than three conductors in raceway or cable or earth(directly buried), based on ambient temperature of 30℃. �� : These values are the outer diameter of the solid or concentric stranded class B conductor. For stranded conductor, the compress stranding may be available to reduce the conductor diameter. � Building Wire 12 13 Building Wire USE-2 / RHH / RHW-2 TYPE 600V USE-2 / RHH / RHW-2 XLPE Insulation, 600 Volts, 90°C Wet or Dry This wire provides an ideal wiring solution. Type USE-2/RHH/RHW-2 can be utilized as underground service entrance. It offers excellent dielectric, tensile strength and cut resistance properties. Copper Conductor XLPE Insulation APPLICATION STANDARDS General purpose for wiring for lighting and powerresidential commercial, industrial buildings. Suitable for use in circuits not exceeding 600 volts at conductortemperatures not exceeding 90℃ in wet or dry locations. UL Standard 854 for Type USE-2 UL Standard 44 for Type RHH/RHW-2 Conductor Size PRODUCT CONSTRUCTION AWG or MCM mm2 No. of Strands Insulation Thickness Diameter Approx. Overall Diameter Approx. Weight lbs/ 1000ft � Ampacity mm mils mm mils mm 91.5 1.14 45 4.3 169 30 20.2 20 mils kg/km Conductor 12 3.31 7 2.32 Conductors shall be class B stranded annealed bare conductor 10 5.26 7 2.95 116 1.14 45 5.1 201 48 32.1 30 8 8.37 7 3.71 146 1.52 60 6.9 272 76 51.0 55 Insulation 6 13.3 7 4.67 184 1.52 60 7.9 311 121 81.1 75 XLPE(cross-linked polyethylene) Abrasion, heat and moisture resistant 4 21.2 7 5.89 232 1.52 60 9.4 370 192 128.9 95 3 26.7 7 6.6 260 1.52 60 9.9 390 242 162.5 110 Identification Color 2 33.6 7 7.42 292 1.52 60 10.9 429 305 204.9 130 Black, White, Red, Green, Yellow, Brown, Blue, Orange, Gray 1 42.4 19 8.33 328 2.03 80 13 512 385 258.4 150 1/0 42.4 19 9.47 373 2.03 80 14.2 559 485 325.8 170 Print Legend 2/0 67.4 19 10.64 419 2.03 80 15.2 598 611 410.9 195 E111359 (UL) SIZE 600V TYPE USE-2 OR RHH OR RHW-2 3/0 85.4 19 11.94 470 2.03 80 16.8 661 771 518.1 225 4/0 107 19 13.41 528 2.03 80 18.3 720 972 653.3 260 Packaging 250 127 37 14.61 575 2.41 95 20.3 799 1,149 771.9 290 14AWG : 2×500′in a carton or 2500′reel 12AWG and 10AWG : 1×500′in a carton or 2500′reel 8AWG and larger : cut to order 300 152 37 16 630 2.41 95 21.8 858 1,379 926.3 320 350 177 37 17.3 681 2.41 95 23.1 909 1,609 1,081 350 400 203 37 18.49 728 2.41 95 23.9 941 1,838 1,235 380 500 253 37 20.65 813 2.41 95 26.7 1,051 2,298 1,544 430 750 380 61 25.35 998 2.79 110 32.3 1,272 3,447 2,316 535 �: Per Table 310-16 of the National Electrical Code, 1996 edition. Conditions : Not more than three conductors in raceway or cable or earth(directly buried), based on ambient temperature of 30℃. Building Wire 14 15 Building Wire USE-2 / RHH / RHW-2 TYPE 600V USE-2 / RHH / RHW-2 XLPE Insulation, 600 Volts, 90°C Wet or Dry This wire provides an ideal wiring solution. Type USE-2/RHH/RHW-2 can be utilized as underground service entrance. It offers excellent dielectric, tensile strength and cut resistance properties. Copper Conductor XLPE Insulation APPLICATION STANDARDS General purpose for wiring for lighting and powerresidential commercial, industrial buildings. Suitable for use in circuits not exceeding 600 volts at conductortemperatures not exceeding 90℃ in wet or dry locations. UL Standard 854 for Type USE-2 UL Standard 44 for Type RHH/RHW-2 Conductor Size PRODUCT CONSTRUCTION AWG or MCM mm2 No. of Strands Insulation Thickness Diameter Approx. Overall Diameter Approx. Weight lbs/ 1000ft � Ampacity mm mils mm mils mm 91.5 1.14 45 4.3 169 30 20.2 20 mils kg/km Conductor 12 3.31 7 2.32 Conductors shall be class B stranded annealed bare conductor 10 5.26 7 2.95 116 1.14 45 5.1 201 48 32.1 30 8 8.37 7 3.71 146 1.52 60 6.9 272 76 51.0 55 Insulation 6 13.3 7 4.67 184 1.52 60 7.9 311 121 81.1 75 XLPE(cross-linked polyethylene) Abrasion, heat and moisture resistant 4 21.2 7 5.89 232 1.52 60 9.4 370 192 128.9 95 3 26.7 7 6.6 260 1.52 60 9.9 390 242 162.5 110 Identification Color 2 33.6 7 7.42 292 1.52 60 10.9 429 305 204.9 130 Black, White, Red, Green, Yellow, Brown, Blue, Orange, Gray 1 42.4 19 8.33 328 2.03 80 13 512 385 258.4 150 1/0 42.4 19 9.47 373 2.03 80 14.2 559 485 325.8 170 Print Legend 2/0 67.4 19 10.64 419 2.03 80 15.2 598 611 410.9 195 E111359 (UL) SIZE 600V TYPE USE-2 OR RHH OR RHW-2 3/0 85.4 19 11.94 470 2.03 80 16.8 661 771 518.1 225 4/0 107 19 13.41 528 2.03 80 18.3 720 972 653.3 260 Packaging 250 127 37 14.61 575 2.41 95 20.3 799 1,149 771.9 290 14AWG : 2×500′in a carton or 2500′reel 12AWG and 10AWG : 1×500′in a carton or 2500′reel 8AWG and larger : cut to order 300 152 37 16 630 2.41 95 21.8 858 1,379 926.3 320 350 177 37 17.3 681 2.41 95 23.1 909 1,609 1,081 350 400 203 37 18.49 728 2.41 95 23.9 941 1,838 1,235 380 500 253 37 20.65 813 2.41 95 26.7 1,051 2,298 1,544 430 750 380 61 25.35 998 2.79 110 32.3 1,272 3,447 2,316 535 �: Per Table 310-16 of the National Electrical Code, 1996 edition. Conditions : Not more than three conductors in raceway or cable or earth(directly buried), based on ambient temperature of 30℃. Building Wire 14 15 Building Wire URD, Duplex TYPE 600V URD, Duplex XLPE Insulation, 600 Volts, 90°C The cables are recommended for directly buried or installed in ducts for 600 volt secondary distribution. Duplex cable is designed for application as a secondary in twowire, single-phase underground distribution systems operated at 600 volts or less. It can be installed in direct burial or in ducts. Aluminum Conductor XLPE Insulation APPLICATIONS �Underground distribution from a power supply source to the service entrance equipment of a building �Maximum operating temperature of 90℃ �Direct burial application or in ducts �600 volts STANDARDS ASTM B-230, B-231 and ICEA S-66-524 UL Standard 854 for Type USE Phase Conductor Code Name Size Strands AWG Neutral Insulation Thickness Size mils AWG Strands Single Phase Insulation Thickness Conductor Ampacity Approx. Overall Diameter Weight lbs/1000ft mils inches inches Direct Burial In Duct Bard 8 7/w 60 8 7/w 60 0.262 0.524 76 70 70 Claflin 6 7/w 60 6 7/w 60 0.299 0.606 104 95 70 Delgado 4 7/w 60 4 7/w 60 0.345 0.700 138 125 90 Everett 2 7/w 60 2 7/w 60 0.403 0.806 189 187 100 PRODUCT CONSTRUCTION Identification Color Black phase conductors Yellow striped neutral or numbering Packaging Master cutting lengths on non-returnable wooden reels Building Wire 16 17 Building Wire URD, Duplex TYPE 600V URD, Duplex XLPE Insulation, 600 Volts, 90°C The cables are recommended for directly buried or installed in ducts for 600 volt secondary distribution. Duplex cable is designed for application as a secondary in twowire, single-phase underground distribution systems operated at 600 volts or less. It can be installed in direct burial or in ducts. Aluminum Conductor XLPE Insulation APPLICATIONS �Underground distribution from a power supply source to the service entrance equipment of a building �Maximum operating temperature of 90℃ �Direct burial application or in ducts �600 volts STANDARDS ASTM B-230, B-231 and ICEA S-66-524 UL Standard 854 for Type USE Phase Conductor Code Name Size Strands AWG Neutral Insulation Thickness Size mils AWG Strands Single Phase Insulation Thickness Conductor Ampacity Approx. Overall Diameter Weight lbs/1000ft mils inches inches Direct Burial In Duct Bard 8 7/w 60 8 7/w 60 0.262 0.524 76 70 70 Claflin 6 7/w 60 6 7/w 60 0.299 0.606 104 95 70 Delgado 4 7/w 60 4 7/w 60 0.345 0.700 138 125 90 Everett 2 7/w 60 2 7/w 60 0.403 0.806 189 187 100 PRODUCT CONSTRUCTION Identification Color Black phase conductors Yellow striped neutral or numbering Packaging Master cutting lengths on non-returnable wooden reels Building Wire 16 17 Building Wire URD, Triplex TYPE 600V URD, Triplex XLPE Insulation, 600 Volts, 90°C The cables are recommended for directly buried or installed in ducts for 600 volt secondary distribution. Triplex cable is designed for application as a secondary in threewire, single-phase underground distribution systems operated at 600 volts or less. It can be installed in direct burial or in ducts. Aluminum Conductor XLPE Insulation APPLICATIONS �Underground distribution from a power supply source to the service entrance equipment of a building �Maximum operating temperature of 90℃ �Direct burial application or in ducts �600 volts Size Strands AWG Insulation Thickness Size mils AWG Strands Single Approx. Phase Overall Insulation Thickness Conductor Diameter mils inches inches Ampacity Weight In Duct Direct Burial lbs/1000ft 6 7/w 60 6 7/w 60 0.299 0.646 143 95 70 STANDARDS Vassar 4 7/w 60 4 7/w 60 0.345 0.754 203 125 90 ASTM B-230, B-231 and ICEA S-66-524 UL Standard 854 for Type USE Stephens 2 7/w 60 4 7/w 60 0.403 0.842 264 165 120 Ramapo 2 7/w 60 2 7/w 60 0.403 0.874 294 165 120 Brenau 1/0 19/w 80 2 7/w 60 0.522 1.064 408 215 160 Bergen 1/0 19/w 80 1/0 19/w 80 0.522 1.133 465 215 160 Converse 2/0 19/w 80 1 19/w 80 0.566 1.174 502 245 180 Hunter 2/0 19/w 80 2/0 19/w 80 0.566 1.228 560 245 180 Packaging Hollins 3/0 19/w 80 1/0 19/w 80 0.616 1.276 606 280 205 Master cutting lengths on non-returnable wooden reels Rockland 3/0 19/w 80 3/0 19/w 80 0.616 1.336 678 280 205 Sweetbriar 4/0 19/w 80 2/0 19/w 80 0.672 1.389 739 315 240 Monmouth 4/0 19/w 80 4/0 19/w 80 0.672 1.457 828 315 240 Pratt 250 37/w 95 3/0 19/w 80 0.748 1.538 893 345 265 Wesleyan 350 37/w 95 4/0 19/w 80 0.851 1.736 1,166 415 320 Holyoke 500 37/w 95 300 37/w 95 0.979 2.008 1,607 495 395 Rider 500 37/w 95 350 37/w 95 0.979 2.035 1,663 495 395 Fairfield 750 61/w 110 500 37/w 95 1.188 2.086 2,304 615 525 Identification Color Black phase conductors Yellow striped neutral or numbering 18 Code Name Neutral Erksine PRODUCT CONSTRUCTION Building Wire Phase Conductor 19 Building Wire URD, Triplex TYPE 600V URD, Triplex XLPE Insulation, 600 Volts, 90°C The cables are recommended for directly buried or installed in ducts for 600 volt secondary distribution. Triplex cable is designed for application as a secondary in threewire, single-phase underground distribution systems operated at 600 volts or less. It can be installed in direct burial or in ducts. Aluminum Conductor XLPE Insulation APPLICATIONS �Underground distribution from a power supply source to the service entrance equipment of a building �Maximum operating temperature of 90℃ �Direct burial application or in ducts �600 volts Size Strands AWG Insulation Thickness Size mils AWG Strands Single Approx. Phase Overall Insulation Thickness Conductor Diameter mils inches inches Ampacity Weight In Duct Direct Burial lbs/1000ft 6 7/w 60 6 7/w 60 0.299 0.646 143 95 70 STANDARDS Vassar 4 7/w 60 4 7/w 60 0.345 0.754 203 125 90 ASTM B-230, B-231 and ICEA S-66-524 UL Standard 854 for Type USE Stephens 2 7/w 60 4 7/w 60 0.403 0.842 264 165 120 Ramapo 2 7/w 60 2 7/w 60 0.403 0.874 294 165 120 Brenau 1/0 19/w 80 2 7/w 60 0.522 1.064 408 215 160 Bergen 1/0 19/w 80 1/0 19/w 80 0.522 1.133 465 215 160 Converse 2/0 19/w 80 1 19/w 80 0.566 1.174 502 245 180 Hunter 2/0 19/w 80 2/0 19/w 80 0.566 1.228 560 245 180 Packaging Hollins 3/0 19/w 80 1/0 19/w 80 0.616 1.276 606 280 205 Master cutting lengths on non-returnable wooden reels Rockland 3/0 19/w 80 3/0 19/w 80 0.616 1.336 678 280 205 Sweetbriar 4/0 19/w 80 2/0 19/w 80 0.672 1.389 739 315 240 Monmouth 4/0 19/w 80 4/0 19/w 80 0.672 1.457 828 315 240 Pratt 250 37/w 95 3/0 19/w 80 0.748 1.538 893 345 265 Wesleyan 350 37/w 95 4/0 19/w 80 0.851 1.736 1,166 415 320 Holyoke 500 37/w 95 300 37/w 95 0.979 2.008 1,607 495 395 Rider 500 37/w 95 350 37/w 95 0.979 2.035 1,663 495 395 Fairfield 750 61/w 110 500 37/w 95 1.188 2.086 2,304 615 525 Identification Color Black phase conductors Yellow striped neutral or numbering 18 Code Name Neutral Erksine PRODUCT CONSTRUCTION Building Wire Phase Conductor 19 Building Wire URD, Quadruplex TYPE 600V URD, Quadruplex XLPE Insulation, 600 Volts, 90°C The cables are recommended for directly buried or installed in ducts for 600 volt secondary distribution. Quadruplex cable is designed for application as a secondary in three-phase, four-wire, underground distribution systems operated at 600 volts or less. It can be installed in direct burial or in ducts. Aluminum Conductor XLPE Insulation APPLICATIONS �Underground distribution from a supply source to the service entrance equipment of a building �Maximum operating temperature of 90℃ �Direct burial application or in ducts �600 volts Size Strands AWG Insulation Thickness Size mils AWG Strands Single Approx. Phase Overall Insulation Thickness Conductor Diameter mils inches inches Ampacity Weight Direct Burial In Duct lbs/1000ft 4 7/w 60 4 7/w 60 0.345 0.845 270 120 85 Dyke 2 7/w 60 4 7/w 60 0.403 0.945 361 155 115 ASTM B-230, B-231 and ICEA S-66-524 UL Standard 854 for Type USE Wittenberg 2 7/w 60 2 7/w 60 0.403 0.985 391 155 115 Notre Dame 1/0 19/w 80 2 7/w 60 0.522 1.231 562 200 150 PRODUCT CONSTRUCTION Purdue 1/0 19/w 80 1/0 19/w 80 0.522 1.270 619 200 150 Syracuse 2/0 19/w 80 1 19/w 80 0.566 1.338 688 225 170 Black phase conductors Yellow striped neutral or numbering Lafayette 2/0 19/w 80 2/0 19/w 80 0.566 1.376 745 225 170 Swarthmore 3/0 19/w 80 1/0 19/w 80 0.616 1.449 832 250 195 Packaging Davidson 3/0 19/w 80 3/0 19/w 80 0.616 1.497 903 250 195 Wake Forest 4/0 19/w 80 2/0 19/w 80 1.622 1.587 1,014 290 225 Earlham 4/0 19/w 80 4/0 19/w 80 1.672 1.632 1,103 290 225 Slippery Rock 350 37/w 95 4/0 19/w 80 0.851 2.054 1,632 385 305 Wofford 500 37/w 95 350 37/w 95 0.851 2.348 2,174 467 420 Windham 750 61/w 110 500 37/w 95 0.979 2.850 2,542 615 492 Identification Color Master cutting lengths on non-returnable wooden reels 20 Code Name Neutral Tulsa STANDARDS Building Wire Phase Conductor 21 Building Wire URD, Quadruplex TYPE 600V URD, Quadruplex XLPE Insulation, 600 Volts, 90°C The cables are recommended for directly buried or installed in ducts for 600 volt secondary distribution. Quadruplex cable is designed for application as a secondary in three-phase, four-wire, underground distribution systems operated at 600 volts or less. It can be installed in direct burial or in ducts. Aluminum Conductor XLPE Insulation APPLICATIONS �Underground distribution from a supply source to the service entrance equipment of a building �Maximum operating temperature of 90℃ �Direct burial application or in ducts �600 volts Size Strands AWG Insulation Thickness Size mils AWG Strands Single Approx. Phase Overall Insulation Thickness Conductor Diameter mils inches inches Ampacity Weight Direct Burial In Duct lbs/1000ft 4 7/w 60 4 7/w 60 0.345 0.845 270 120 85 Dyke 2 7/w 60 4 7/w 60 0.403 0.945 361 155 115 ASTM B-230, B-231 and ICEA S-66-524 UL Standard 854 for Type USE Wittenberg 2 7/w 60 2 7/w 60 0.403 0.985 391 155 115 Notre Dame 1/0 19/w 80 2 7/w 60 0.522 1.231 562 200 150 PRODUCT CONSTRUCTION Purdue 1/0 19/w 80 1/0 19/w 80 0.522 1.270 619 200 150 Syracuse 2/0 19/w 80 1 19/w 80 0.566 1.338 688 225 170 Black phase conductors Yellow striped neutral or numbering Lafayette 2/0 19/w 80 2/0 19/w 80 0.566 1.376 745 225 170 Swarthmore 3/0 19/w 80 1/0 19/w 80 0.616 1.449 832 250 195 Packaging Davidson 3/0 19/w 80 3/0 19/w 80 0.616 1.497 903 250 195 Wake Forest 4/0 19/w 80 2/0 19/w 80 1.622 1.587 1,014 290 225 Earlham 4/0 19/w 80 4/0 19/w 80 1.672 1.632 1,103 290 225 Slippery Rock 350 37/w 95 4/0 19/w 80 0.851 2.054 1,632 385 305 Wofford 500 37/w 95 350 37/w 95 0.851 2.348 2,174 467 420 Windham 750 61/w 110 500 37/w 95 0.979 2.850 2,542 615 492 Identification Color Master cutting lengths on non-returnable wooden reels 20 Code Name Neutral Tulsa STANDARDS Building Wire Phase Conductor 21 Building Wire TC CONTROL CABLE TYPE 600V TC CONTROL CABLE TFFN, THWN or THHN Conductors, PVC Jacket, 600 Volts, 90°C Copper Conductors The cables are recommended for operation at 90°C maximum continuous conductor temperature in dry location and 75°C for wet locations. TFFN, THWN or THHN Conductors PVC Jacket APPLICATIONS STANDARDS �Industrial control, lighting and signal circuits where small diameter, flame retardant cables are required. �Primary installations in cable trays, raceways or outdoor locations where supported by a messenger wire �Approved for direct burial, Class 1, Div. 2 hazardous locations per NEC� Article 501 and Class 1 circuits per NEC� Article 725 UL Standard 1581 for CT use UL Standard 1277 for direct burial and sunlight resistance IEEE 383(70,000 Btu/hr) vertical cable tray flame tests PRODUCT CONSTRUCTION Conductor Bare annealed copper per ASTM B-3 Class B stranding per ASTM B-8 Insulation Heat resistant PVC with an oil and gasoline resistant nylon jacket per UL 83 for Type THHN/THWN and UL 62 for Type TFFN Jacket Heat, moisture and sunlight resistant PVC Color Code ICEA Method 1, K-2 18AWG (7 strands) TFFN/PVC No. of Conductors 2(Flat) 2(Round) 3 4 5 6 7 9 10 12 15 16 19 20 25 30 37 Identification Color ICEA S-66-524, Method 1, Table K-2 or numbering with black insulation Print Legend E111360 (UL) SIZE 600V TYPE TC THHN OR THWN {CDRS} SUNLIGHT RESISTANT DIRECT BURIAL Packaging Master cutting lengths on non-returnable wooden reels Building Wire 22 Nominal Nominal Jacket Outer Diameter Thickness 14AWG (7 strands) THHN-THWN/PVC mils inches Shipping Weight per mft 45 45 45 45 45 45 45 45 45 45 45 60 60 60 60 60 60 0.18X0.26 0.27 0.28 0.30 0.32 0.35 0.37 0.44 0.45 0.46 0.49 0.51 0.57 0.58 0.65 0.69 0.75 41 42 50 60 71 80 89 112 127 156 169 191 214 226 285 330 390 12AWG (7 strands) THHN-THWN/PVC 2(Flat) 2(Round) 3 4 5 6 7 9 10 12 15 16 19 20 25 30 37 45 45 45 45 45 45 60 60 60 60 60 60 60 80 80 80 80 0.23X0.36 0.36 0.38 0.41 0.45 0.49 0.53 0.60 0.64 0.67 0.74 0.76 0.80 0.82 0.96 1.03 1.12 75 86 109 135 165 191 220 295 318 375 452 484 565 630 768 895 1,089 Nominal Jacket Approx Overall Diameter Thickness mils inches Shipping Weight per mft 45 45 45 45 45 45 45 60 60 60 60 60 60 60 60 80 80 0.20X0.32 0.32 0.34 0.37 0.40 0.43 0.45 0.51 0.57 0.59 0.66 0.67 0.71 0.72 0.80 0.91 0.98 60 65 80 100 120 140 160 220 230 275 330 350 400 420 520 660 780 10AWG (7 strands) THHN-THWN/PVC 45 45 45 45 60 60 60 60 60 60 0.26X0.42 0.42 0.45 0.49 0.57 0.62 0.66 0.72 0.79 0.80 108 115 162 198 255 298 344 435 475 560 Conductor Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Tracer Stripe Base Color Black Red Blue Orange Yellow Brown Red Black Blue Black Orange Black Yellow Black Brown Black Black Red Blue Red Orange Red Yellow Red Brown Red Black Blue Red Blue Orange Blue Yellow Blue Brown Blue Black Orange Red Orange Blue Orange Yellow Orange Brown Orange Black Yellow Red Yellow Blue Yellow Orange Yellow Brown Yellow Black Brown Red Brown Blue Brown Orange Brown Yellow Brown Red Black-Blue 23 Building Wire TC CONTROL CABLE TYPE 600V TC CONTROL CABLE TFFN, THWN or THHN Conductors, PVC Jacket, 600 Volts, 90°C Copper Conductors The cables are recommended for operation at 90°C maximum continuous conductor temperature in dry location and 75°C for wet locations. TFFN, THWN or THHN Conductors PVC Jacket APPLICATIONS STANDARDS �Industrial control, lighting and signal circuits where small diameter, flame retardant cables are required. �Primary installations in cable trays, raceways or outdoor locations where supported by a messenger wire �Approved for direct burial, Class 1, Div. 2 hazardous locations per NEC� Article 501 and Class 1 circuits per NEC� Article 725 UL Standard 1581 for CT use UL Standard 1277 for direct burial and sunlight resistance IEEE 383(70,000 Btu/hr) vertical cable tray flame tests PRODUCT CONSTRUCTION Conductor Bare annealed copper per ASTM B-3 Class B stranding per ASTM B-8 Insulation Heat resistant PVC with an oil and gasoline resistant nylon jacket per UL 83 for Type THHN/THWN and UL 62 for Type TFFN Jacket Heat, moisture and sunlight resistant PVC Color Code ICEA Method 1, K-2 18AWG (7 strands) TFFN/PVC No. of Conductors 2(Flat) 2(Round) 3 4 5 6 7 9 10 12 15 16 19 20 25 30 37 Identification Color ICEA S-66-524, Method 1, Table K-2 or numbering with black insulation Print Legend E111360 (UL) SIZE 600V TYPE TC THHN OR THWN {CDRS} SUNLIGHT RESISTANT DIRECT BURIAL Packaging Master cutting lengths on non-returnable wooden reels Building Wire 22 Nominal Nominal Jacket Outer Diameter Thickness 14AWG (7 strands) THHN-THWN/PVC mils inches Shipping Weight per mft 45 45 45 45 45 45 45 45 45 45 45 60 60 60 60 60 60 0.18X0.26 0.27 0.28 0.30 0.32 0.35 0.37 0.44 0.45 0.46 0.49 0.51 0.57 0.58 0.65 0.69 0.75 41 42 50 60 71 80 89 112 127 156 169 191 214 226 285 330 390 12AWG (7 strands) THHN-THWN/PVC 2(Flat) 2(Round) 3 4 5 6 7 9 10 12 15 16 19 20 25 30 37 45 45 45 45 45 45 60 60 60 60 60 60 60 80 80 80 80 0.23X0.36 0.36 0.38 0.41 0.45 0.49 0.53 0.60 0.64 0.67 0.74 0.76 0.80 0.82 0.96 1.03 1.12 75 86 109 135 165 191 220 295 318 375 452 484 565 630 768 895 1,089 Nominal Jacket Approx Overall Diameter Thickness mils inches Shipping Weight per mft 45 45 45 45 45 45 45 60 60 60 60 60 60 60 60 80 80 0.20X0.32 0.32 0.34 0.37 0.40 0.43 0.45 0.51 0.57 0.59 0.66 0.67 0.71 0.72 0.80 0.91 0.98 60 65 80 100 120 140 160 220 230 275 330 350 400 420 520 660 780 10AWG (7 strands) THHN-THWN/PVC 45 45 45 45 60 60 60 60 60 60 0.26X0.42 0.42 0.45 0.49 0.57 0.62 0.66 0.72 0.79 0.80 108 115 162 198 255 298 344 435 475 560 Conductor Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Tracer Stripe Base Color Black Red Blue Orange Yellow Brown Red Black Blue Black Orange Black Yellow Black Brown Black Black Red Blue Red Orange Red Yellow Red Brown Red Black Blue Red Blue Orange Blue Yellow Blue Brown Blue Black Orange Red Orange Blue Orange Yellow Orange Brown Orange Black Yellow Red Yellow Blue Yellow Orange Yellow Brown Yellow Black Brown Red Brown Blue Brown Orange Brown Yellow Brown Red Black-Blue 23 Building Wire TC POWER CABLE TYPE 600V TC POWER CABLE THHN-THWN/PVC with Ground, 600 Volts, 90°C Dry, 75°C Wet Grounding Conductor The cables are recommended for operation at 90°C maximum continuous conductor temperature in dry location and 75°C for wet locations. Copper Conductor THWN-THHN Conductors PVC Jacket APPLICATIONS STANDARDS �Industrial power to motors and other electrical devices �Primary installations in cable trays, raceways or outdoor locations where supported by a messenger wire �Approved for direct burial, Class 1, Div. 2 hazardous locations per NEC� Article 501 and Class 1 circuits per NEC� Article 725 UL Standard 1581 for CT use UL Standard 1277 for direct burial and sunlight resistance IEEE 383(70,000 Btu/hr) vertical cable tray flame tests PRODUCT CONSTRUCTION Conductor Bare annealed copper per ASTM B-8 Class B stranding per ASTM B-8 or B-787 Insulation Heat resistant PVC with an oil and gasoline resistant nylon jacket per UL 83 for Type THHN/THWN Jacket Heat, moisture and sunlight resistant PVC Identification Color ICEA S-66-524, Method 4 Print Legend E111360 (UL) SIZE 600V TYPE TC THHN OR THWN {CDRS} SUNLIGHT RESISTANT DIRECT BURIAL Packaging Master cutting lengths on non-returnable wooden reels Conductor Size AWG/MCM No. of Strands No. of Conductor 8 8 6 6 4 4 2 2 1 1/0 2/0 3/0 4/0 8 8 6 6 4 4 2 1/0 2/0 3/0 4/0 7 7 7 7 7 7 7 7 19 19 19 19 19 7 7 7 7 7 7 7 19 19 19 19 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 1 2 3 4 24 Nominal Jacket Thickness Nominal Outer Diameter AWG mils inches 10 8 8 6 6 6 6 4 4 10 8 8 6 6 4 4 4 60 60 60 60 60 60 80 80 80 80 80 80 80 60 60 60 60 60 60 80 80 80 80 110 0.65 0.65 0.73 0.73 0.85 0.85 1.01 1.01 1.21 1.25 1.38 1.42 1.55 0.71 0.71 0.79 0.79 0.95 0.95 1.10 1.35 1.45 1.58 1.78 Shipping Weight per mft 315 285 430 380 705 655 990 910 1,205 1,460 1,840 2,190 2,750 385 352 543 492 825 757 1,230 1,810 2,450 2,665 3,500 Color Code - ICEA Method 4 Conductor Number Building Wire Ground Size Base Color Black Black Black Black Printed Surface 1-ONE 2-TWO 3-THREE 4-FOUR 25 Building Wire TC POWER CABLE TYPE 600V TC POWER CABLE THHN-THWN/PVC with Ground, 600 Volts, 90°C Dry, 75°C Wet Grounding Conductor The cables are recommended for operation at 90°C maximum continuous conductor temperature in dry location and 75°C for wet locations. Copper Conductor THWN-THHN Conductors PVC Jacket APPLICATIONS STANDARDS �Industrial power to motors and other electrical devices �Primary installations in cable trays, raceways or outdoor locations where supported by a messenger wire �Approved for direct burial, Class 1, Div. 2 hazardous locations per NEC� Article 501 and Class 1 circuits per NEC� Article 725 UL Standard 1581 for CT use UL Standard 1277 for direct burial and sunlight resistance IEEE 383(70,000 Btu/hr) vertical cable tray flame tests PRODUCT CONSTRUCTION Conductor Bare annealed copper per ASTM B-8 Class B stranding per ASTM B-8 or B-787 Insulation Heat resistant PVC with an oil and gasoline resistant nylon jacket per UL 83 for Type THHN/THWN Jacket Heat, moisture and sunlight resistant PVC Identification Color ICEA S-66-524, Method 4 Print Legend E111360 (UL) SIZE 600V TYPE TC THHN OR THWN {CDRS} SUNLIGHT RESISTANT DIRECT BURIAL Packaging Master cutting lengths on non-returnable wooden reels Conductor Size AWG/MCM No. of Strands No. of Conductor 8 8 6 6 4 4 2 2 1 1/0 2/0 3/0 4/0 8 8 6 6 4 4 2 1/0 2/0 3/0 4/0 7 7 7 7 7 7 7 7 19 19 19 19 19 7 7 7 7 7 7 7 19 19 19 19 3 3 3 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 1 2 3 4 24 Nominal Jacket Thickness Nominal Outer Diameter AWG mils inches 10 8 8 6 6 6 6 4 4 10 8 8 6 6 4 4 4 60 60 60 60 60 60 80 80 80 80 80 80 80 60 60 60 60 60 60 80 80 80 80 110 0.65 0.65 0.73 0.73 0.85 0.85 1.01 1.01 1.21 1.25 1.38 1.42 1.55 0.71 0.71 0.79 0.79 0.95 0.95 1.10 1.35 1.45 1.58 1.78 Shipping Weight per mft 315 285 430 380 705 655 990 910 1,205 1,460 1,840 2,190 2,750 385 352 543 492 825 757 1,230 1,810 2,450 2,665 3,500 Color Code - ICEA Method 4 Conductor Number Building Wire Ground Size Base Color Black Black Black Black Printed Surface 1-ONE 2-TWO 3-THREE 4-FOUR 25 Building Wire TC POWER CABLE TYPE 600V TC POWER CABLE XHHW-2/PVC with Ground, 600 Volts, 90°C Wet or Dry Uncoated Copper Ground Conductors The cables are recommended for operation at 90°C maximum continuous conductor temperature in wet or dry locations. Uncoated Copper Conductors XLPE Insulation Fillers Tape PVC Jacket APPLICATIONS STANDARDS �Industrial power to motors and other electrical devices �Primary installations in cable trays, raceways or outdoor locations where supported by a messenger wire �Approved for direct burial, Class 1, Div. 2 hazardous locations per NEC� Article 501 and Class 1 circuits per NEC� Article 725 UL Standard 1581 for CT use UL Standard 1277 for direct burial and sunlight resistance UL Standard 44 for rubber insulated wires and cables IEEE 383(70,000 Btu/hr) vertical cable tray flame tests Three Conductors with Grounding Conductor PRODUCT CONSTRUCTION Conductor Bare annealed copper per ASTM B-8 Insulation Conductor shall be insulated with cross-linked polyethylene, meeting the requirements Type XHHW-2 of UL 44 Identification Color Size Thickness (mils) No. of Strands AWG or kcmil 8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1,000 Insulation Jacket 45 45 45 45 55 55 55 55 55 65 65 65 80 80 60 60 80 80 80 80 80 80 80 110 110 110 110 140 7 7 7 7 19 19 19 19 19 37 37 37 61 61 Size Print Legend E111360 (UL) SIZE 600V TYPE TC XHHW-2 {CDRS} SUNLIGHT RESISTANT DIRECT BURIAL Packaging Master cutting lengths on non-returnable wooden reels Color Code - ICEA Method 4 26 � Grounding Conductor Size Approx. Net Weight inches AWG lbs/1000ft 0.66 0.74 0.88 1.00 1.13 1.22 1.31 1.42 1.55 1.76 1.98 2.26 2.71 3.10 10 8 8 6 6 6 6 4 4 4 3 2 1 1/0 325 450 655 960 1,170 1,425 1,720 2,140 2,635 3,180 4,285 5,940 9,010 11,700 55 75 95 130 150 170 195 225 260 290 350 430 535 615 Nominal Diameter �Grounding Conductor Size Approx. Net Weight �� Ampacity ��� Ampacity-tray 44 60 76 104 120 136 156 180 208 232 280 344 428 55 75 95 130 150 170 195 225 260 290 350 430 535 �� Ampacity Four Conductors with Grounding Conductors ICEA S-66-524, Method 4 Building Wire Nominal Diameter Conductor Number Base Color Printed Surface 1 2 3 4 Black Black Black Black 1-ONE 2-TWO 3-THREE 4-FOUR No. of Strands AWG or kcmil 8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 7 7 7 7 19 19 19 19 19 37 37 37 61 Thickness (mils) Insulation Jacket inches AWG lbs/1000ft 45 45 45 45 55 55 55 55 55 65 65 65 80 60 60 80 80 80 80 80 80 110 110 110 110 140 0.72 0.81 0.96 1.10 1.25 1.35 1.45 1.58 1.77 1.93 2.18 2.50 3.12 12 10 10 9 9 9 9 7 7 7 6 5 4 415 575 840 1,200 1,545 1,835 2,195 2,800 3,460 4,040 5,475 7,635 11,400 � : Grounding conductors per UL Standard 1277 for Type TC Tray Cable. �� : Ampacity in accordance with the National Electrical Code for cables in raceway or directly buried, at the conductor temperature indicated in wet or dry locations, 30℃ ambient temperature. ���: Ampacity in accordance with Art. 318-11 of the National Electrical Code for cables installed in uncovered cable tray with or without maintained spacing, at the conductor temperature indicated in wet or dry locations, 30℃ ambient temperature. Derating for more than three conductors per Note 8 is not required for cable in tray. 27 Building Wire TC POWER CABLE TYPE 600V TC POWER CABLE XHHW-2/PVC with Ground, 600 Volts, 90°C Wet or Dry Uncoated Copper Ground Conductors The cables are recommended for operation at 90°C maximum continuous conductor temperature in wet or dry locations. Uncoated Copper Conductors XLPE Insulation Fillers Tape PVC Jacket APPLICATIONS STANDARDS �Industrial power to motors and other electrical devices �Primary installations in cable trays, raceways or outdoor locations where supported by a messenger wire �Approved for direct burial, Class 1, Div. 2 hazardous locations per NEC� Article 501 and Class 1 circuits per NEC� Article 725 UL Standard 1581 for CT use UL Standard 1277 for direct burial and sunlight resistance UL Standard 44 for rubber insulated wires and cables IEEE 383(70,000 Btu/hr) vertical cable tray flame tests Three Conductors with Grounding Conductor PRODUCT CONSTRUCTION Conductor Bare annealed copper per ASTM B-8 Insulation Conductor shall be insulated with cross-linked polyethylene, meeting the requirements Type XHHW-2 of UL 44 Identification Color Size Thickness (mils) No. of Strands AWG or kcmil 8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 1,000 Insulation Jacket 45 45 45 45 55 55 55 55 55 65 65 65 80 80 60 60 80 80 80 80 80 80 80 110 110 110 110 140 7 7 7 7 19 19 19 19 19 37 37 37 61 61 Size Print Legend E111360 (UL) SIZE 600V TYPE TC XHHW-2 {CDRS} SUNLIGHT RESISTANT DIRECT BURIAL Packaging Master cutting lengths on non-returnable wooden reels Color Code - ICEA Method 4 26 � Grounding Conductor Size Approx. Net Weight inches AWG lbs/1000ft 0.66 0.74 0.88 1.00 1.13 1.22 1.31 1.42 1.55 1.76 1.98 2.26 2.71 3.10 10 8 8 6 6 6 6 4 4 4 3 2 1 1/0 325 450 655 960 1,170 1,425 1,720 2,140 2,635 3,180 4,285 5,940 9,010 11,700 55 75 95 130 150 170 195 225 260 290 350 430 535 615 Nominal Diameter �Grounding Conductor Size Approx. Net Weight �� Ampacity ��� Ampacity-tray 44 60 76 104 120 136 156 180 208 232 280 344 428 55 75 95 130 150 170 195 225 260 290 350 430 535 �� Ampacity Four Conductors with Grounding Conductors ICEA S-66-524, Method 4 Building Wire Nominal Diameter Conductor Number Base Color Printed Surface 1 2 3 4 Black Black Black Black 1-ONE 2-TWO 3-THREE 4-FOUR No. of Strands AWG or kcmil 8 6 4 2 1 1/0 2/0 3/0 4/0 250 350 500 750 7 7 7 7 19 19 19 19 19 37 37 37 61 Thickness (mils) Insulation Jacket inches AWG lbs/1000ft 45 45 45 45 55 55 55 55 55 65 65 65 80 60 60 80 80 80 80 80 80 110 110 110 110 140 0.72 0.81 0.96 1.10 1.25 1.35 1.45 1.58 1.77 1.93 2.18 2.50 3.12 12 10 10 9 9 9 9 7 7 7 6 5 4 415 575 840 1,200 1,545 1,835 2,195 2,800 3,460 4,040 5,475 7,635 11,400 � : Grounding conductors per UL Standard 1277 for Type TC Tray Cable. �� : Ampacity in accordance with the National Electrical Code for cables in raceway or directly buried, at the conductor temperature indicated in wet or dry locations, 30℃ ambient temperature. ���: Ampacity in accordance with Art. 318-11 of the National Electrical Code for cables installed in uncovered cable tray with or without maintained spacing, at the conductor temperature indicated in wet or dry locations, 30℃ ambient temperature. Derating for more than three conductors per Note 8 is not required for cable in tray. 27 Building Wire www.taihan.com Head Office Insong Bldg.194-15, 1-ga, Hoehyeon-dong, Jung-gu, Seoul, Korea Tel. 82-2-316-9114 Fax. 82-2-754-5493 Overseas Sales Team Tel. 82-2-316-9425, 9430 Fax. 82-2-754-5481 Domestic Sales Team Tel . 82-2-316-9267, 9310 Fax. 82-2-754-5493 R&D CENTER AND PLANTS OVERSEAS SUBSIDIARIES R & D Center 785, Gwanyang-dong, Dongan-ku, Anyang, Gyunggi-do, Korea Anyang Plant 785, Gwanyang-dong, Dongan-ku, Anyang, Gyunggi-do, Korea Shihung Plant 113-119, Shihung-dong, Kumchon-gu, Seoul, Korea Ansan Plant 603, Seonggok-dong, Danwon-ku, Ansan, Gyunggi-do, Korea Malesela Taihan Electric Cable(Pty) Ltd. Vereeniging 1930, Steel Road, Peacehaven Vereeniging 1939, Gauteng, South Africa Skytel Co., Ltd Skytel Plaza Building ChinggisKhan Ave-9, Ulaanbaatar 210603, Mongolia Tel. 82-31-420-9590 Fax. 82-31-423-2685 Tel. 82-31-420-9114 Fax. 82-31-423-2685 Tel. 82-2-890-9114 Fax. 82-2-892-9387 Tel. 82-31-490-5114 Fax. 82-31-491-3721 Tel. 27-16-450-8200 Fax. 27-16-423-3406 htth://www. m-tec.co.za Tel. 976-11-318488 Fax. 976-11-318487 htth://www.skytel.com OVERSEAS OFFICES Kuala Lumpur Office 15th Floor, Kenanga International, JL. Sultan Ismail, 50250 Kuala Lumpur, Malaysia Riyadh Office AI Akariyah Shopping Center 2, Room No. 726, Olaya Road, P.O.Box 201, Riyadh, Saudi Arabia Sanghai Office A410 Far EastInternational Plaza 319 Xian Xia Road Changning District, Shanghai, China Philippines Office 10A Queen’s Street Dona Rita Village Talamban Cebu City 6000 Dubai Office Flat no. 705, Al Safa Tower, Sheikh Zayed Road, Dubai, U.A.E P.O.Box117561 Tailand Office 253, 26th Floor Asoke, Sukhumvit 21 Road, Klongtoeynua, Wattana, Bangkok 10110, Thailand Tel. 65-6842-5069 Fax. 65-6842-5076 Tel. 60-3-2161-8017 Fax. 60-3-2161-3628 Tel. 966-1-419-0227 Fax. 966-1-419-0262 Tel. 86-21-6235-1263 Fax. 86-21-6235-1267 Tel. 63-32-346-8799 Fax. 63-32-346-8799 Tel. 97-14-331-7233 Fax. 97-14-331-7322 Tel. 66-2-664-1464 Fax. 66-2-664-4002 �Specifications are subject to improvement or change without notice. Please contact your local agent or TAIHAN to confirm the latest product information TPE-0701-0509 Singapore Office 629 Aljunied Road #05-19 Cititech Industrial Building, Singapore, 389838, Singapore