CONTRACT 2013-24B DOVER WELL PUMP STATION OCTOBER, 2015 N N PROJECT LOCATION PROJECT LOCATION 9 1 CITY OF PITTSBURG 10/20/15 BID SET CONTRACT 2013-24B 10/20/15 DOVER PRODUCTION WELL ELECTRICAL LOG DOVER PRODUCTION WELL PROFILE Description Depth CONTRACT 2013-24B DOVER TEST HOLE LITHLOGY N THE DATA PROVIDED ON THIS SHEET IS FOR INFORMATION PURPOSES. SEE SHEET M-4 FOR INFORMATION REGARDING THE PUMP AND PEDESTAL INSTALLATION. 10/20/15 ACCESSORY PIPE ORIENTATION 10/20/15 CONTRACT 2013-24B 10/20/15 CONTRACT 2013-24B 10/20/15 CONTRACT 2013-24B 10/20/15 CONTRACT 2013-24B 10/20/15 CONTRACT 2013-24B 10/20/15 CONTRACT 2013-24B 10/20/15 CONTRACT 2013-24B CONTRACT 2013-24B PRESSURE GAUGE DETAIL AIR RELEASE AND VACUUM VALVE DETAIL A TIE-ROD ASSEMBLY DETAIL D B SAMPLE TAP DETAIL E M-1 10/20/15 CONTRACT 2013-24B 10/20/15 PRODUCTION CASING AIR VENT PUMP PEDESTAL - MECHANICAL A M-1 PRESSURE TRANSMITTER E M-1 B M-1 CONTRACT 2013-24B 10/20/15 LEVEL TRANSDUCER HOSE RACK C M-1 A M-1 10/20/15 10/20/15 10/20/15 10/20/15 = = DUPLEX OUTLET, 20A, 120V, GROUNDED; +15'' MIN. CONDUIT, EXPOSED; OR CONCEALED IN WALL OR CEILING = CONDUIT, UNDERGROUND = CONDUIT, EXISTING = GROUND WIRE = PANELBOARD = MOTOR, FRACTIONAL HP = MOTOR STARTER - MAGNETIC PB = CHART RECORDER = DUPLEX OUTLET, ISOLATED GROUND, 20A 120V, GROUNDED; +15'' MIN. CIT = CHLORINE INDICATING TRANSMITTER = FOURPLEX OUTLET, 20A, 120V, GROUNDED; +15'' MIN. CMP = CHLORINE METERING PUMP CRT = CHLORINE RESIDUAL TRANSMITTER = JUNCTION BOX; CEILING OR WALL = TRANSFORMER = MOTOR, 1HP OR ABOVE CR = SPECIAL OUTLET, AS NOTED = POINT OF INTERCEPTION SENSORS AND INSTRUMENTS: = DUPLEX OUTLET, GFI PROTECTED, 20A, 120V, GROUNDED; +15'' MIN. J = BRANCH CIRCUIT HOMERUN FRT = FLOURIDE RESIDUAL TRANSMITTER DPS = DIFFERENTIAL PRESSURE SWITCH FIT = FLOW INDICATING TRANSMITTER = THERMOSTAT; +60'' U.O.N. = DISCONNECT SWITCH, FUSED U.O.N = MECHANICAL EQUIPMENT DESIGNATION = COMBINATION STARTER DISCONNECT = CIRCUIT BREAKER = PULLBOX (PB) OR MANHOLE (MH) = CONTACTOR OR RELAY COIL FLS HPS = FLOW SWITCH = HIGH PRESSURE SWITCH = SMOKE DETECTOR = FLUORESCENT FIXTURE, RECESSED = FLUORESCENT FIXTURE, SURFACE = WALLPACK FIXTURE = SPOT OR FLOOD LIGHT = INTRUSION SWITCH = INTRUSION RESET BUTTON LPS LCV = LOW PRESSURE SWITCH = LIMIT CONTROL VALVE LFS = LEVEL FLOAT SWITCH LIT = LEVEL INDICATING TRANSMITTER LLS = LOW LEVEL SWITCH PCV = PUMP CONTROL VALVE = EXIT & EMERGENCY = FIXTURE DESIGNATION = CONDUIT TURNS DOWN OR DOWN = UTILITY REVENUE METER = SWITCH, S.P.S.T.; +48'' MAX. 3 = SWITCH, 3-WAY; +48'' MAX. P = SWITCH, W/ PILOT LIGHT; +48'' MAX. TS = SWITCH, THERMAL; +48'' MAX. K = SWITCH, KEY OPERATED; +48'' MAX. M m BT a PIT = PRESSURE INDICATING TRANSMITTER SOL = SOLENOID VALVE TSH = TEMPERATURE SWITCH HIGH = SWITCH, MOTOR RATED; MOUNTED AT UNIT U.O.N. = SWITCH, MOTION; +48'' MAX. ULT = TIMER SWITCH; +48'' MAX. = ULTRASONIC LEVEL TRANSMITTER = ULTRASONIC LEVEL SESNOR = SUBSCRIPT LETTER ADJACENT TO SYMBOL INDICATES CONTROL = OCCUPANCY SENSOR = ANTENNA YAGI OTHER: = INDICATES CONDUIT SCHEDULE NUMBER = INDICATES REVISON NUMBER = INDICATES REFERENCE NUMBER OF SHEET NOTE 3 I&C = NUMBER ADJACENT TO SYMBOL INDICATES CIRCUIT NUMBER ON PANELBOARD = INSTALL & CONNECT F&I = FURNISH AND INSTALL +24" = INDICATES MOUNTING HEIGHT TO CENTER OF DEVICE A.F.F. ATS = AUTOMATIC TRANSFER SWITCH AFF = ABOVE FINISH FLOOR (OR A.F.F.) AFG = ABOVE FINISHED GRADE (OR A.F.G.) CKT = CIRCUIT E.C. = ELECTRICAL CONTRACTOR GFI = GROUND FAULT PROTECTED CIRCUIT OR OUTLET MAX. = MAXIMUM MIN. = MINIMUM NIC = NOT IN CONTRACT WP = ADJACENT TO SYMBOL INDICATES WEATHER PROOF DEVICE (OR W.P.) WPIUC = ADJACENT TO SYMBOL INDICATES WEATHER PROOF DEVICE W/ IN-USE COVER U.O.N. = UNLESS OTHERWISE NOTED PDP = POWER DISTRIBUTION PANEL HP = HORSE POWER MS = MOTOR STARTER A/C = AIR CONDITIONER LP = LIGHTING PANEL (N) = NEW (E) = EXISTING TVSS = TRANSIENT VOLTAGE SURGE SUPRESSION SSRV = SOLID STATE REDUCED VOLTAGE STARTER VFD = VARIABLE FREQUENCY DRIVE = MOTION SENSOR - ONE WAY = MOTION SENSOR - TWO WAY CAM = (F) CAMERA (NOT IN CONTRACT) IN GENERAL - DASHED SYMBOLS DENOTE EXISTING SYMBOLS INDICATED ABOVE MAY NOT NECESSARILY APPEAR AS PART OF THESE DRAWINGS IF NOT REQUIRED. = SWITCH PACK = PHOTO CELL JOE PREVENDAR P.E. CA EE 16581 joe@epsfresno.com 10/20/15 Know what's below. Call before you dig. GARY OLSEN P.E. CA EE 8283 gary@epsfresno.com JOB: LS-13-160 DATE: AUG 2015 FILE: LS160-01SYM PLOT: 9/11/2015 1:36 PM / 0.5:1 DSGN: JPP DRWN: AVS EPS IS RESPONSIBLE FOR ELECTRICAL SYSTEMS DESIGN ONLY. EPS IS NOT RESPONSIBLE FOR ELECTRICAL SAFETY WORK PROCEDURES AND/OR USE OF REQUIRED PERSONAL PROTECTIVE EQUIPMENT, SEE NFPA 70E "STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE'' AND OSHA 29 CFR. CONTRACTOR MUST READ SPECIFICATIONS AND INSTALL MATERIAL AS PER SPECIFICATIONS AND/OR PLANS OR AS PER E.P.S. APPROVAL. PLANS AND SPECIFICATIONS ONLY APPLY TO THE PROJECT FOR WHICH THEY WERE CREATED. PROFESSIONAL AND CONSULTING ELECTRICAL ENGINEERING 4049 N FRESNO ST, FRESNO , CA 93726 P: (559) 221-7230 F: (559) 221-0507 ABOVE GRADE - HOT DIPPED GALVANIZED RIGID STEEL CONDUIT TO BE USED FOR ALL EXTERIOR AND INTERIOR LOCATIONS ABOVE GRADE OR ELSEWHERE SHOWN ON PLANS. ALL RIGID CONDUIT AND FITTINGS TO BE THREADED. USE OF SET SCREW OR COMPRESSION TYPE CONNECTOR IS PROHIBITED. MEYERS HUBS TO BE USED ON ALL EXTERIOR PANEL CONNECTIONS. BELOW GRADE - RIGID PVC NONMETALLIC CONDUIT SCHEDULE 40 TO BE USED FOR ALL UNDERGROUND LOCATIONS AND BELOW VAPOR BARRIER OF SLAB. NO CONDUITS SHALL BE INSTALLED TO REDUCE THE STRUCTURAL INTEGRITY OF FOOTINGS. CHEMICAL BUILDINGS AND CORROSIVE ATMOSPHERES - RIGID PVC NONMETALLIC CONDUIT SCHEDULE 80 TO BE USED FOR ALL INTERIOR LOCATIONS ABOVE GRADE IN CHEMICAL BUILDINGS AND CORROSIVE ENVIRONMENTS. 0 1 2 THROUGH CONCRETE SLABS AND EXTERIOR CORROSIVE ATMOSPHERES PVC COATED GALVANIZED RIGID STEEL CONDUIT MINIMUM 40 MIL FACTORY COATING TO BE USED FOR ALL EXPOSED CONDUITS THROUGH CONCRETE SLABS (MINIMUM 12'' ABOVE AND BELOW SLAB) AND ALL EXTERIOR LOCATION CORROSIVE ATMOSPHERES. USE MANUFACTURERS' SPECIFIED TOOLS AND PROCEDURES FOR INSTALLATION. 4 MOTOR OR SENSOR CONNECTIONS - LIQUID TIGHT FLEXIBLE METAL CONDUIT (UV RESISTANT) TO ONLY BE USED ON CONNECTIONS TO MOTORS OR SENSORS. MAXIMUM LENGTH TO BE 30''. JUNCTION BOXES - MINIMUM SIZE PER NEC. EXPOSED LOCATION, 1 AND 2 GANG TO BE CAST IRON DEVICE BOXES TYPE FS/FD SUITABLE FOR WET LOCATIONS. EXPOSED LOCATION EXTERIOR LARGER SIZES CONTINUOUS HINGE TYPE 4, CORROSIVE LOCATIONS CONTINUOUS HINGE TYPE 4X STAINLESS STEEL. GROUND CONNECTIONS - GROUND CONNECTIONS TO BE EXOTHERMIC CADWELD (ALL 600 AMP OR LARGER SERVICE) OR BURNDY HYDRAULIC COMPRESSION CONNECTORS. GROUND BUS CONNECTIONS TO BE CRIMP LUG TYPE WITH BOLTED CONNECTION TO GROUND BUS. 480 VOLT AND BELOW POWER WIRING TO BE THWN-2 600 VOLT, ALL POWER CONNECTIONS TO BE TREATED WITH ANTIOXIDANT COMPOUND. *** CONTACT EPS TO SCHEDULE AN ELECTRICAL PRECONSTRUCTION MEETING PRIOR TO COMMENCING CONSTRUCTION *** JOE PREVENDAR P.E. CA EE 16581 joe@epsfresno.com 10/20/15 Know what's below. Call before you dig. GARY OLSEN P.E. CA EE 8283 gary@epsfresno.com JOB: LS-13-160 DATE: AUG 2015 FILE: LS160-02SP PLOT: 9/11/2015 1:35 PM / 0.5:1 DSGN: JPP DRWN: AVS EPS IS RESPONSIBLE FOR ELECTRICAL SYSTEMS DESIGN ONLY. EPS IS NOT RESPONSIBLE FOR ELECTRICAL SAFETY WORK PROCEDURES AND/OR USE OF REQUIRED PERSONAL PROTECTIVE EQUIPMENT, SEE NFPA 70E "STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE'' AND OSHA 29 CFR. CONTRACTOR MUST READ SPECIFICATIONS AND INSTALL MATERIAL AS PER SPECIFICATIONS AND/OR PLANS OR AS PER E.P.S. APPROVAL. PLANS AND SPECIFICATIONS ONLY APPLY TO THE PROJECT FOR WHICH THEY WERE CREATED. PROFESSIONAL AND CONSULTING ELECTRICAL ENGINEERING 4049 N FRESNO ST, FRESNO , CA 93726 P: (559) 221-7230 F: (559) 221-0507 ABOVE GRADE - HOT DIPPED GALVANIZED RIGID STEEL CONDUIT TO BE USED FOR ALL EXTERIOR AND INTERIOR LOCATIONS ABOVE GRADE OR ELSEWHERE SHOWN ON PLANS. ALL RIGID CONDUIT AND FITTINGS TO BE THREADED. USE OF SET SCREW OR COMPRESSION TYPE CONNECTOR IS PROHIBITED. MEYERS HUBS TO BE USED ON ALL EXTERIOR PANEL CONNECTIONS. BELOW GRADE - RIGID PVC NONMETALLIC CONDUIT SCHEDULE 40 TO BE USED FOR ALL UNDERGROUND LOCATIONS AND BELOW VAPOR BARRIER OF SLAB. NO CONDUITS SHALL BE INSTALLED TO REDUCE THE STRUCTURAL INTEGRITY OF FOOTINGS. CHEMICAL BUILDINGS AND CORROSIVE ATMOSPHERES - RIGID PVC NONMETALLIC CONDUIT SCHEDULE 80 TO BE USED FOR ALL INTERIOR LOCATIONS ABOVE GRADE IN CHEMICAL BUILDINGS AND CORROSIVE ENVIRONMENTS. THROUGH CONCRETE SLABS AND EXTERIOR CORROSIVE ATMOSPHERES PVC COATED GALVANIZED RIGID STEEL CONDUIT MINIMUM 40 MIL FACTORY COATING TO BE USED FOR ALL EXPOSED CONDUITS THROUGH CONCRETE SLABS (MINIMUM 12'' ABOVE AND BELOW SLAB) AND ALL EXTERIOR LOCATION CORROSIVE ATMOSPHERES. USE MANUFACTURERS' SPECIFIED TOOLS AND PROCEDURES FOR INSTALLATION. MOTOR OR SENSOR CONNECTIONS - LIQUID TIGHT FLEXIBLE METAL CONDUIT (UV RESISTANT) TO ONLY BE USED ON CONNECTIONS TO MOTORS OR SENSORS. MAXIMUM LENGTH TO BE 30''. 0 1 2 JUNCTION BOXES - MINIMUM SIZE PER NEC. EXPOSED LOCATION, 1 AND 2 GANG TO BE CAST IRON DEVICE BOXES TYPE FS/FD SUITABLE FOR WET LOCATIONS. EXPOSED LOCATION EXTERIOR LARGER SIZES CONTINUOUS HINGE TYPE 4, CORROSIVE LOCATIONS CONTINUOUS HINGE TYPE 4X STAINLESS STEEL. 4 GROUND CONNECTIONS - GROUND CONNECTIONS TO BE EXOTHERMIC CADWELD (ALL 600 AMP OR LARGER SERVICE) OR BURNDY HYDRAULIC COMPRESSION CONNECTORS. GROUND BUS CONNECTIONS TO BE CRIMP LUG TYPE WITH BOLTED CONNECTION TO GROUND BUS. 480 VOLT AND BELOW POWER WIRING TO BE THWN-2 600 VOLT, ALL POWER CONNECTIONS TO BE TREATED WITH ANTIOXIDANT COMPOUND. *** CONTACT EPS TO SCHEDULE AN ELECTRICAL PRECONSTRUCTION MEETING PRIOR TO COMMENCING CONSTRUCTION *** (B) - 8' LED STRIP - DUST AND MOISTURE TIGHT, RAPID START, ANY TEMPERATURE, 120V ELECTRONIC BALLAST 8' LITHONIA FEM8LED LINEAR ROUGH SERVICE, ACRYLIC CLEAR DEEP LENS, 78 WATTS, 4100K, WITH MOUNTING BRACKETS OR EQUAL; HOLOPHANE EMS8LED 9L IMAFL, LINEAR INDUSTRIAL LED, LENS & GASKETED WITH STAINLESS STEEL CLIPS, MVOLT, FROSTED ACRYLIC LENS, 4100K. (C1) - LED WALL PACK INDOOR/OUTDOOR W/ PE, MOTION DETECTOR & OVERRIDE SWITCH HOLOPHANE WALLPACK IV W4GLED-10C-1000-40K-T3M-MVOLT-PE-BZ, LITHONIA TWH LED 10C 1000 40K T3M MVOLT OR EQUAL OUTDOOR WEATHERPROOF MOTION DETECTOR WATTSTOPPER EW OR EQUAL Know what's below. Call before you dig. JOE PREVENDAR P.E. CA EE 16581 joe@epsfresno.com 10/20/15 GARY OLSEN P.E. CA EE 8283 gary@epsfresno.com JOB: LS-13-160 DATE: AUG 2015 FILE: LS160-03BP PLOT: 9/11/2015 1:33 PM / 0.5:1 DSGN: JPP DRWN: AVS EPS IS RESPONSIBLE FOR ELECTRICAL SYSTEMS DESIGN ONLY. EPS IS NOT RESPONSIBLE FOR ELECTRICAL SAFETY WORK PROCEDURES AND/OR USE OF REQUIRED PERSONAL PROTECTIVE EQUIPMENT, SEE NFPA 70E "STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE'' AND OSHA 29 CFR. CONTRACTOR MUST READ SPECIFICATIONS AND INSTALL MATERIAL AS PER SPECIFICATIONS AND/OR PLANS OR AS PER E.P.S. APPROVAL. PLANS AND SPECIFICATIONS ONLY APPLY TO THE PROJECT FOR WHICH THEY WERE CREATED. PROFESSIONAL AND CONSULTING ELECTRICAL ENGINEERING 4049 N FRESNO ST, FRESNO , CA 93726 P: (559) 221-7230 F: (559) 221-0507 METER SECTION METER SOCKET PER PG&E STANDARDS LIGHT 60'' PORTABLE GENERATOR BY OTHERS MECHANICAL INTERLOCK CB GENERATOR PLUG ARKTITE RECEPTACLE CAT AR4041 400A (MALE) 4W-4P LIGHT SWITCH CB LOCKABLE 120V 20A GFI OUTDOOR RECEPTACLE 400A RECEPTACLE PER CITY SPEC REVERSE SERVICE STYLE 2 400/3 UTILITY METERING M ALL SECTIONS ARE 20'' DEEP SURGE PROTECTION DEVICE 240kA/ POWER MONITOR I.L. 400A-3P SERVICE DISCONNECT SHIPPING SPLIT 24'' 20'' 20'' 20'' 20'' SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 400A-3P GENERATOR DISCONNECT TESCO SERVICE PEDESTAL OR APPROVED EQUAL 30/3 400A-480/277V-42kAIC-CU 30'' 400/3 5 40/2 250/3 HMCP 26'' 9 1 15KVA XFMR 480-120/240V 400A-3P TM 8 VFD OID 15 20 100/2 12 10 LINE CONDUIT AREA 11 PANEL `LP' VFD 16 SSRV 21 14 2 dV/dT 90'' 11 7 17 6 VFD 150 HP 50°C TVSS SSRV NOTE: PLC ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL A SECOND ARKTITE RECEPTACLE (MALE) TO REPLACE (E) MALE GENERATOR PLUG ON THE BODEGA WELL. I.L. NOTES: 12'' 9.5'' A 6 REACTOR LOAD CONDUIT AREA 10 3 1) VFD - RATED 150% FLA FOR 60 SECONDS 4 2) POWER METER - ELECTRO-IND SHARK 200 W/ ETHERNET OR EQUAL 3) SSRV RATED 125% FLA 150 40A-2P TM 100A-2P TM WELL 15kVA TRANSFORMER HEATER HEATER HEATER HEATER NOTES: 1) NEMA 1G ENCLOSURE 2) OPERATOR CONTROLS BETWEEN 46" AND 66" 3) VFD RATED 150% FLA FOR 60 SECONDS - HEAVY DUTY 4) REDUNDANT COOLING FANS JOE PREVENDAR P.E. CA EE 16581 joe@epsfresno.com 10/20/15 GARY OLSEN P.E. CA EE 8283 gary@epsfresno.com DATE: AUG 2015 JOB: LS-13-160 FILE: LS160-04SL PLOT: 9/11/2015 1:31 PM / 0.5:1 DSGN: JPP DRWN: AVS EPS IS RESPONSIBLE FOR ELECTRICAL SYSTEMS DESIGN ONLY. EPS IS NOT RESPONSIBLE FOR ELECTRICAL SAFETY WORK PROCEDURES AND/OR USE OF REQUIRED PERSONAL PROTECTIVE EQUIPMENT, SEE NFPA 70E "STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE'' AND OSHA 29 CFR. CONTRACTOR MUST READ SPECIFICATIONS AND INSTALL MATERIAL AS PER SPECIFICATIONS AND/OR PLANS OR AS PER E.P.S. APPROVAL. PLANS AND SPECIFICATIONS ONLY APPLY TO THE PROJECT FOR WHICH THEY WERE CREATED. PROFESSIONAL AND CONSULTING ELECTRICAL ENGINEERING 4049 N FRESNO ST, FRESNO , CA 93726 P: (559) 221-7230 F: (559) 221-0507 480V 3Ø 18 PULSE CPT N 120VAC CONTROL POWER AVAILABLE PUMP CALL DELAY `PLC' `DI' PUMP IN: HAND CONTROL POWER H-O-A H xoo TE oox H xoo TE oox CONTROL POWER ON PUMP CALL A xo CALL DOOR MOUNT DISPLAY H VFD VFD FAULT ox VFD RUN PRE-LUBE SOLENOID `PLC' `DO' PUMP CALL CR TELEMETRY MTS - MOTOR THERMOSTAT SWITCH ADJUSTIBLE SPEED DRIVE AC CONTROLLER 150% FLA FOR 1 MIN. `PLC' `DI' START ON DELAY 0-5 MIN. VFD RUN MANUAL SPEED POTENTIOMETER PRE-LUBE START DELAY ONE SHOT TIMER BST - BACKSPIN TIMER ONE SHOT PULSE AFTER PUMP SHUTDOWN VFD FAULT `PLC' `AO' FAULT SPEED REFERENCE PUMP TO WASTE TIMER 4-20mA FREEZE ETHERNET COM LINK TO PLC PUMP TO WASTE SOLENOID VALVE SOLENOID DEENERGIZED VALVE OPENS TO WASTE SSRV START SSRV `PUMP CONTROL VALVE' RUN VFD RUNNING NC C NO CHLORINE CHEMICAL PUMP CONTROL FLUORIDE CHEMICAL PUMP CONTROL I.L. UL APPROVED OL ALGORITHM `PLC' `DI' HPS ON PUMP HIGH PRESSURE TRIP TDON 0-5 MIN. 240V, 20A RATED CL CHEM PUMP ON FAULT WELL MOTOR 120V FROM `LP' PUMP FAIL DOOR MOUNT DISPLAY VALVE LIMIT SWITCH NORMALLY CLOSED HELD OPEN BY TELLTALE CAM WHEN VALVE FULLY OPEN 2CR KEEPS PUMP ON UNTIL VALVE FULLY OPEN ON SHUTDOWN 3CR KEEPS PUMP FROM STARTING IF VALVE NOT OPEN AFTER POWER FAIL CHEMICAL PUMP(S) ON TO CPP 120V, 20A RATED FL CHEM PUMP ON JOE PREVENDAR P.E. CA EE 16581 joe@epsfresno.com 10/20/15 Know what's below. Call before you dig. GARY OLSEN P.E. CA EE 8283 gary@epsfresno.com JOB: LS-13-160 DATE: AUG 2015 FILE: LS160-05CD PLOT: 9/11/2015 1:30 PM / 0.5:1 DSGN: JPP DRWN: AVS EPS IS RESPONSIBLE FOR ELECTRICAL SYSTEMS DESIGN ONLY. EPS IS NOT RESPONSIBLE FOR ELECTRICAL SAFETY WORK PROCEDURES AND/OR USE OF REQUIRED PERSONAL PROTECTIVE EQUIPMENT, SEE NFPA 70E "STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE'' AND OSHA 29 CFR. CONTRACTOR MUST READ SPECIFICATIONS AND INSTALL MATERIAL AS PER SPECIFICATIONS AND/OR PLANS OR AS PER E.P.S. APPROVAL. PLANS AND SPECIFICATIONS ONLY APPLY TO THE PROJECT FOR WHICH THEY WERE CREATED. PROFESSIONAL AND CONSULTING ELECTRICAL ENGINEERING 4049 N FRESNO ST, FRESNO , CA 93726 P: (559) 221-7230 F: (559) 221-0507 PLC GE 90/30 OR PAC R31 ELECTRICAL CONTRACTOR TO VERIFY HEIGHT AND DIRECTION W/ RADIO SURVEY LIGHTNING ARRESTER MDS iNET SERIES II 2900 RADIO 120VAC UPS 240 MINUTE BATTERY BACKUP, APC OR EQUAL NOTE: RADIO FREQUENCY & PROTOCOL PER CITY STANDARD 24VDC POWER SUPPLY PORT EXPANDER 15" COLOR LCD KEYPAD & TOUCHSCREEN GE 1C754V5115CTD QUICK PANEL A. GENERAL THE WELL PUMP HAS 3 MODES OF OPERATION: REMOTE RATIO, AUTO FLOW AND HAND. THESE MODES ARE SELECTED BY A SELECTOR SWITCH ON THE PUMP STARTER. THE PUMP STARTER IS A VARIABLE FREQUENCY DRIVE WHICH VARIES PUMP SPEED TO MAINTAIN A FLOW SET POINT. THE INTENT IS TO MAINTAIN POTABLE WATER TDS (TOTAL DISSOLVED SOLIDS) BELOW STATE REQUIREMENTS. THE STARTUP SEQUENCE IS AS FOLLOWS: 1. WELL IS CALLED BY WTP SCADA OPERATOR OR TIME OF DAY CLOCK 2. WELL PUMP VFD STARTS. 3. THE PUMP RAMPS UP TO PUMP TO A FLOW SET POINT. PUMP SPEED IS MODULATED THROUGH A PI CONTROLLER TO MAINTAIN FLOW. THE WELL LEVEL IS MONITORED. AT A LOW WELL LEVEL SET POINT THE MOTOR SPEED WILL AUTOMATICALLY BE REDUCED TO ENSURE THE WELL DOES NOT BREAK SUCTION. A PRESSURE AND LEVEL SET POINTS ARE USER ADJUSTABLE. THE SHUTDOWN SEQUENCE IS AS FOLLOWS: 4. PUMP WILL RUN UNTIL AN ADJUSTABLE LOW FLOW RATE IS RUN AT FOR AN ADJUSTABLE TIME PERIOD OR IF THE HIGH PRESSURE SWITCH SENSES HIGH PRESSURE OR IF LOW WELL LEVEL CUTOFF IS REACHED. 5. AN ADJUSTABLE BACKSPIN TIMER STARTS TIMING ON PUMP SHUTDOWN PREVENTING PUMP RESTART UNTIL THE WATER COLUMN HAS SETTLED. B. MODES OF OPERATION 1. REMOTE RATIO MODE: A FLOW SET POINT IS SENT VIA RADIO TELEMETRY TO RATIO WELL FLOW TO WATER TREATMENT PLANT FLOW. 2. AUTO FLOW MODE: THE AUTO MODE IS CONTROLLED USING TIME OF DAY TO START THE PUMP AND THEN MODULATING SPEED TO CONTROL TO A FLOW SET POINT. 3. HAND MODE: THE HAND MODE IS A MAINTENANCE TEST MODE TO RUN THE PUMP LOCALLY WITH THE MANUAL POTENTIOMETER CONTROLLING SPEED. C. CHLORINATION INJECTION (FUTURE) 1. AUTO FLOW MODE: AUTO INJECTS CHEMICAL WHENEVER THE WELL PUMP MOTOR IS RUNNING. THE RATE IS RATIOED TO MEASURED WELL FLOW. 2. AUTO FIXED MODE: AUTO INJECTS CHEMICAL WHENEVER THE WELL PUMP MOTOR IS RUNNING. THE RATE IS MANUALLY SET. 3. JOG MODE: JOG OPERATION IS A MAINTENANCE TEST MODE THAT RUNS THE CHEMICAL PUMP WHEN THE BUTTON IS PRESSED. JOE PREVENDAR P.E. CA EE 16581 joe@epsfresno.com 10/20/15 Know what's below. Call before you dig. GARY OLSEN P.E. CA EE 8283 gary@epsfresno.com JOB: LS-13-160 DATE: AUG 2015 FILE: LS160-06PLC PLOT: 9/11/2015 1:29 PM / 0.5:1 DSGN: JPP DRWN: AVS EPS IS RESPONSIBLE FOR ELECTRICAL SYSTEMS DESIGN ONLY. EPS IS NOT RESPONSIBLE FOR ELECTRICAL SAFETY WORK PROCEDURES AND/OR USE OF REQUIRED PERSONAL PROTECTIVE EQUIPMENT, SEE NFPA 70E "STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE'' AND OSHA 29 CFR. CONTRACTOR MUST READ SPECIFICATIONS AND INSTALL MATERIAL AS PER SPECIFICATIONS AND/OR PLANS OR AS PER E.P.S. APPROVAL. PLANS AND SPECIFICATIONS ONLY APPLY TO THE PROJECT FOR WHICH THEY WERE CREATED. PROFESSIONAL AND CONSULTING ELECTRICAL ENGINEERING 4049 N FRESNO ST, FRESNO , CA 93726 P: (559) 221-7230 F: (559) 221-0507 CONCRETE CONDITION: SAW CUT EXISTING (FLUSH) AND PATCH BACK W/ MIN 5'' THICK CONCRETE SLAB (MIN 6 STACK MIX), MATCH EXISTING FINISH LEGEND TYPICAL 3 4 "x10' COPPER CLAD GROUND ROD, MIN. 12" FROM EDGE OF SLAB AND 10' FROM GROUND ROD IN SERVICE SECTION NEUTRAL BUS TO GROUND BUS BOND CONNECTION GROUND ROD COMPRESSION LUG CONNECTION BOLTED TO GROUND BUS 3 " 2-HOLE BOLTED CONNECTION 8 USING BELLEVILLE WASHER GROUND CLAMP THERMO WELD OR BURNDY COMPRESSION UNPAVED CONDITION: EARTH BACKFILL PER SPECS. 12" MIN WARNING! GFI 36" MIN BOND TO INCOMING METAL COLD WATER PIPE IF AVAILABLE BOND TO REBAR FIXED GUARD POSTS PER PG&E REQUIREMENTS. SEE DETAIL THIS SHEET. SPACE PER RULE 16 24" 24" EARTH BACKFILL PER SPECS. GR UNDERGROUND CONDUITS (ELEC., COMM., EMS, ETC.) NUMBER AND SIZE OF CONDUITS AS INDICATED ON PLANS #4/0 BARE CU UFER GROUND, MINIMUM LENGTH 25', MINIMUM 3" CONCRETE ENCASEMENT #4/0 CU PRECAST CONCRETE PAD PER PG&E REQUIREMENTS WARNING TAPE GROUND BUS #4/0 CU TRANSFORMER PER PG&E REQUIREMENTS 24" FINISHED GRADE "REMOVAL OF THIS LINK REMOVES CUSTOMER GROUNDING TO NEUTRAL OF SUPPLY" #4/0 BARE CU GR ASPHALT CONDITION: SAW CUT EXISTING (6" SPACING BOTH SIDES) AND PATCH BACK W/ MIN 5'' ASPHALT (TYPE B) PLACE IN TWO LIFTS OF 2'' OVER 3'', 3 8"Ø MAX AGGREGATE SIZE (BY PAVING CONTRACTOR), APPLY ASPHALT BINDER AT EXISTING PAVEMENT EDGES IMMEDIATELY PRIOR TO PLACING TRENCH RESURFACING 6" UTILITY DISCONNECT LINK, READILY ACCESSIBLE. MARKED: N GROUND ROD (TYPICAL OF 2) PRECAST PAD OPENINGS 36" SAND BACKFILL OR CONCRETE SLURRY PER SPECS. EXCEPT FOR UNDERGROUND POWER RUNS OF GREATER THAN 600 VOLTS TO GROUND WHICH SHALL BE CONCRETE SLURRY ENCASED. 6" 3" 11 2" 11 2 " REMOVABLE GUARD POST PER PG&E REQUIREMENTS. SEE DETAIL THIS SHEET. SPACE PER RULE 16 CONCRETE ENCASEMENT: 2000 PSI SLURRY, TYPICAL ALL UNDERGROUND CONDUITS, 3 8 "Ø MAX AGGREGATE SIZE TOP VIEW 2" APPROVED GROUND CLAMP 3" #2 SOLID/STRANDED AWG CU GROUND WIRE 8" MIN FINISH GRADE NOTE: SERVICE GROUND SIZE AS SHOWN OR AS PER TABLE 250-94-CEC (CURRENT). ALL GROUND CONDUCTORS TO BE COPPER. GROUND CLAMP 2" 6'' ABOVE SLAB GROUND CLAMP 5 "x8' GROUND ROD, 8 COPPERCLAD WITH MIN 6' BETWEEN RODS 1 "x3"x3"x1 1 " ANGLE 4 2 BRACKET - SEE NOTE 4 VERIFY NUMBER OF SECTION(S) ON PLAN(S)/ELEVATION(S) SEE NOTES 3 & 5 SIDE VIEW (CUT THROUGH AT CONDUIT OPENINGS) INCOMING AND OUT GOING CONDUITS A A 3 " BOLT, WASHERS, 8 LOCK WASHERS & NUT - SEE NOTE 4 SET BRANCH CONDUITS OPPOSITE EACH OTHER NOTES: 1) DRAIN PLAN VIEW HILTI KWIK - BOLT ANCHOR (TYPICAL) SEE NOTE 3 TRANSFORMER PAD SIZE & QUANTITY OF GUARD POSTS PER PG&E RULE 16. 2) ALL PG&E RULE 16 APPLY. = FIXED LOCKING STEEL LID LOCKJAW TYPE SEAL CONDUITS WITH DUCT SEAL = REMOVABLE FINISH GRADE GROUT SEE NOTES 1 & 2 CONCRETE PULLBOX WITH EXTENSION 3 "x3 3 " SS HILTI 4 8 KWIK-BOLT AT EACH CORNER OF ENCLOSURE AS SHOWN ABOVE CLAMP TO MOTOR FEED TACK WELD CLAMP TO STAINLESS STEEL LABEL MOUNT 3" PVC 12 GAUGE STAINLESS STEEL 6" MIN INSTALL TAR PAPER BETWEEN ROCK & GROUT & UP 1 1 4 " ON ALL SIDES & SLOPED DOWN TOWARD DRAIN IN CENTER OF BOX 1 1 2" 3 4" CRUSHED ROCK BASE (TYPICAL) (SEE LABEL ABOVE) 1"x3" PVC SLEEVE FOR DRAIN STUB INTO ROCK 3" SIDE VIEW A-A AT MOTOR STAINLESS STEEL BOLTS OR SCREWS MCC-______________ (MOTOR CONTROL CENTER) PUMP _____________ (MOTOR DESCRIPTION) ____ HP (HORSEPOWER) WHITE LAMICOID W/ BLACK LETTERS AT STARTER CHRISTY N9 (#3 1/2), N30 (#5), N36 (#6) OR LARGER PULLBOXES SIMILAR NOTES: Know what's below. Call before you dig. 1) FOR INDOORS - 1 1 2 " HIGH HOUSEKEEPING PAD. 2" WIDE ALONG BACK, BOTH SIDES AND FRONT. 2) FOR OUTDOORS - 3 1 2" HIGH HOUSEKEEPING PAD. 2" WIDE ALONG BACK, BOTH SIDES AND AS SHOWN ON PLANS FOR FRONT. 3) 4 ANCHORS FOR 1ST SECTION AND 2 ANCHORS FOR EACH OTHER SECTION. 4) 2 FOR 1ST SECTION AND 1 FOR EACH OTHER SECTION. 5) FOR CONCRETE WALL. USE 3 8"x3 3 4" HILTI KWIK-BOLT. FOR STUD WALL. USE 3 8"x3" LAG BOLTS. JOE PREVENDAR P.E. CA EE 16581 joe@epsfresno.com 10/20/15 GARY OLSEN P.E. CA EE 8283 gary@epsfresno.com JOB: LS-13-160 DATE: AUG 2015 FILE: LS160-07DT PLOT: 9/11/2015 1:27 PM / 0.5:1 DSGN: JPP DRWN: AVS EPS IS RESPONSIBLE FOR ELECTRICAL SYSTEMS DESIGN ONLY. EPS IS NOT RESPONSIBLE FOR ELECTRICAL SAFETY WORK PROCEDURES AND/OR USE OF REQUIRED PERSONAL PROTECTIVE EQUIPMENT, SEE NFPA 70E "STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE'' AND OSHA 29 CFR. CONTRACTOR MUST READ SPECIFICATIONS AND INSTALL MATERIAL AS PER SPECIFICATIONS AND/OR PLANS OR AS PER E.P.S. APPROVAL. PLANS AND SPECIFICATIONS ONLY APPLY TO THE PROJECT FOR WHICH THEY WERE CREATED. PROFESSIONAL AND CONSULTING ELECTRICAL ENGINEERING 4049 N FRESNO ST, FRESNO , CA 93726 P: (559) 221-7230 F: (559) 221-0507 ROSEMOUNT 3051TG PRESSURE TRANSMITTER W/ LCD DISPLAY 0-100 PSI OR EQUAL PELCO PENDANT CAMERA AND ENCLOSURE OR EQUAL ROOF FIELD SENSOR DEVICE (TR-16 4-20mA) CABLE OR CONDUIT - SEE NOTES BELOW 90° CONNECTOR ROSEMOUNT SINGLE GANG WEATHERPROOF OUTLET BOX W/ BLANK COVER 1 FIELD TERMINALS 2" STEEL CONDULET 3 306RT2 THREADED STYLE MANIFOLD TWO-VALV E (FUTURE) PELCO DIGITAL RECORDER OR EQUAL (NOT IN CONTRACT) SEE NOTE 4 LFMC CONNECTOR W/ 3 4" TO 1 " RE 2 BUSHING 4" MIN 1''C W/ CAT 5E-POE ROOF FASCIA 4 "RMC #18 TSP GUTTER & DOWNSPOUT 3" GALVANIZED STEEL CHANNEL PIPE FINISH GRADE W/ TO CONTROL PANEL 36" MIN 30" PELCO PENDANT CAMERA AND ENCLOSURE OR EQUAL 12"DIAx36" CONCRETE FOUNDATION 21'' COLOR MONITOR PVC COATED RMC CAT-5E TO ETHERNET SWITCH AT PLC SITE CONTROL ROOM PVC NOTES: NOTE: 1) IF FIELD SENSOR DEVICE IS FURNISHED W/ CONDUIT CONNECTION PROVISIONS, CONNECT WITH LFMC. NOTES: 2) IF FIELD SENSOR DEVICE IS EQUIPPED ONLY W/ LIQUIDTIGHT CABLE, RUN INTO WEATHERPROOF OUTLET BOX THROUGH LIQUIDTIGHT CABLE CONNECTOR. 1) ELECTRICAL CONTRACTOR TO PROVIDE CONDUITS FOR CAMERAS AS SHOWN. ALL CAMERA EQUIPMENT AND ENCLOSURES TO BE SUPPLIED AND INSTALLED BY CITY. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH CAMERA INSTALLER. 1) PELCO SARIX IME SERIES VANDAL RESISTANT PENDANT NETWORK MINI-DOME (NOT IN CONTRACT) 2) PELCO SWM CORNER 3 PART PENDANT MOUNT (NOT IN CONTRACT) 3) PELCO DX 4700 VIDEO RECORDER (NOT IN CONTRACT) 4) PROVIDE WALL MOUNT VENTED NEMA 1 ENCLOSURE W/ SEE THRU DOOR (FUTURE) SEE NOTE 1 RUN OIT FAULT 3/4" FLEXTITE MAXIMUM 12" TO 3/4"C SEE NOTE 2 HOA MANUAL SPEED POT VENTS POWER HEATSINK THRU BACK WITH WEATHERPROOF SHROUD VFD ELECTRONICS REDUNDANT COOLING FANS SEE NOTE 1 FRONT NOTES: 1) PMC/BETA VL4513 W/ TE-10 DRY BOX AND MP-11 CABLE TERMINATOR SEALED REFERENCE VOLUME FILLED WITH DRY NITROGEN OR EQUAL 2) THIS IS THE 2-WIRE TWISTED PAIR THAT SUPPLIES THE 9-30VDV EXCITATION AND RETURNS THE 4-20MA CURRENT PROPORTIONAL TO PRESSURE/LEVEL, 4MA - THE MINIMUM AND 20MA = THE MAXIMUM JOE PREVENDAR P.E. CA EE 16581 joe@epsfresno.com 10/20/15 Know what's below. Call before you dig. GARY OLSEN P.E. CA EE 8283 gary@epsfresno.com JOB: LS-13-160 DATE: AUG 2015 FILE: LS160-08DTA PLOT: 9/11/2015 1:25 PM / 0.5:1 DSGN: JPP DRWN: AVS EPS IS RESPONSIBLE FOR ELECTRICAL SYSTEMS DESIGN ONLY. EPS IS NOT RESPONSIBLE FOR ELECTRICAL SAFETY WORK PROCEDURES AND/OR USE OF REQUIRED PERSONAL PROTECTIVE EQUIPMENT, SEE NFPA 70E "STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE'' AND OSHA 29 CFR. CONTRACTOR MUST READ SPECIFICATIONS AND INSTALL MATERIAL AS PER SPECIFICATIONS AND/OR PLANS OR AS PER E.P.S. APPROVAL. PLANS AND SPECIFICATIONS ONLY APPLY TO THE PROJECT FOR WHICH THEY WERE CREATED. PROFESSIONAL AND CONSULTING ELECTRICAL ENGINEERING 4049 N FRESNO ST, FRESNO , CA 93726 P: (559) 221-7230 F: (559) 221-0507