Transformers PDF

advertisement
Transformers
SUBHEAD
ISOLATION
ACME
• Meets UL 1561, CSA, NEMA, ANSI & OSHA standards
• Full Capacity Taps
• Encapsulated Designs
• Quiet Reinforced Core Assemblies
• 1 Phase
• Ten year limited manufacturer warranty
• .25 KVA and larger shielded for cleaner power
Item Number
KVA
Dimensions in" (cm) HxWxD Weight in lbs. (kg)
Price
240 x 480 Primary Volts, 120/240 Secondary Volts, Four Windings, 1 Ø, 60 Hz.
T-2-53007-S
.25
8.68(22) x 4.08(10.4) x 3.88(9.9)
10(4.5)
$175.36
T-2-53008-S
.50
9.06(23) x 4.37(11.1) x 4.20(10.7)
15(6.8)
$203.79
T-2-53009-S
.75
9.68(24.6) x 4.75(11.4) x 4.50(11.4)
19(8.6)
$254.34
T-2-53010-S
1
10.5(26.7) x 5.5(14) x 5.13(13)
24(10.9)
$308.06
T-2-53012-S
2
13(33) x 5.50(14) x 5.13(13)
38(17.2)
$464.47
T-2-53014-4S 5
14.38(36.5) x 10.31(26.2) x 7.13(18.1)
75(34)
$851.53
T-2-53515-3S 7.5
15.19(38.6) x 13.50(34.3) x 10.84(27.5)
115(52.2)
$1,191.19
T-2-53516-3S 10
15.1938.6) x 13.50(34.3) x 10.84(27.5)
125(56.7)
$1,383.93
T-2-53517-3S 15
16.94(43) x 14.12(35.9) x 11.59(29.4)
170(77.1)
$1,829.42
T-2-53518-3S 25
18.44(46.8) x 16.13(41) x 13.34(33.9)
250(113)
$2,256.99
190/208/220/240 x 380/416/440/480 Primary Volts, 120/240 Secondary Volts, 1 Ø, 50/60 Hz.
TF-2-79260-S 1
10.50(26.7) x 5.50(14) x 5.13(13)
24(10.9)
$562.79
TF-2-79261-S 2
13(33) x 5.5(14) x 5.13(13)
38(17.2)
$865.28
TF-2-79263-S 5
14.38(36.5) x 10.31(26.2) x 7.13(18.1)
75(34)
$1,524.87
TF-2-79264-S 7.5
15.19(38.6) x 13.50(34.3) x 10.84(27.5)
115(52.2)
$2,215.91
TF-2-79266-S 15
16.94(43) x 14.12(35.9) x 11.59(29.4)
170(77.1)
$3,144.11
TF-2-79267-S 25
18.44(46.8) x 16.13(41) x 13.34(33.9)
300(136.1)
$4,434.85
Images are representative of products listed and may not be actual product.
274
www.wardsmarine.com
Transformers
ISOLATION/BOOST
SUBHEAD
Charles Marine Industries
Isolation
Isoboost
• Marine UL listing ensures durability and safety
• New European CE EMC Certification on 50Hz.
• Has both “regular” isolation mode and “boost”
• Permits operation of 240VAC systems
• Internal circuitry monitors shore and boat
• Fully encapsulated with full current
• Boost Mode increases output voltage by 15%
• Mechanically interlocked contactors switch the
• Meets all ABYC E-8.20.1 standards
• Convection cooled enclosure meets
models
• Fully encapsulated components and transformer
windings
• Full current carrying shield per ABYC E-8.20.1
• Uses terminal blocks
Dimensions in" (mm) HxWxD
carrying shield
voltages and then adjust output
output between “regular” and “boost” modes,
preventing shorts
ISOLATION
Item Number
from 208VAC dock supply
isolation mode
NMEA 3R requirements
• Marine UL Listed
ISOBOOST REMOTE
Weight in lbs. (kg)
Input Current
Input Voltage
Output Current
Output Voltage
Price
Isolation
93-IXFMR3/8I-A
12(304.8) x 12(304.8) x 10(254)
70(31.75)
32/16 A
120/240, 50/60Hz. 32/16A
120/240, 50/60 Hz.
$1,576.83
50A
167-255, 60Hz.
42.5/ 50A
192-255, 60Hz.
$5,637.36
100A
167-255, 60Hz.
85/100A
192-255, 60Hz.
$13,437.15
Isoboost
93-ISOBOOST50-B
12(304.8) x 15(381) x 18(457.2)
235(106.59)
93-ISOBOOST100-B
17(431.8) x 20.5(520.7) x 20.5(520.7) 575(260.82)
Item Number
Description
Price
93-ISOBREMOTE-A
Remote Panel
$292.85
97-001121-A
Strain Relief Kit ISO Boost 100
$281.14
97-001120-B
Strain Relief Kit ISO Boost 50
$141.10
97-001127-B
Strain Relief Kit for 3.6/3.8 KVA
Accessories
$45.09
Images are representative of products listed and may not be actual product.
www.wardsmarine.com
275
Transformers
SUBHEAD
BOOST
Ward’s Marine Electric
• 10% Fixed Boost
• Portable
• Compact Design
• 208/230 Primary Volt
• Single Phase
The WME Portable Boost Transformers is safe, powerful, and can protect
your 115/230 VAC equipment from many harmful low dock voltage
conditions. Both the 100 ampere and 50 ampere versions are equipped
with durable carrying handles and can be conveniently set next to your
dockside power pedestal. When connected, a static 10% voltage boost is
delivered to provide safer and more effective power to your boat. There
are no manual overrides on these units, so the voltage will be boosted
10% regardless of input voltage.
Not suitable for marinas where erratic voltage fluctuations occur.
Item Number
Description
Price
Portable Boost
BB208/230-50 50 AMP
$1,844.00
BB208/230-100 100 AMP
$3,687.40
*See also Shore Power Boost Equipment
Charles Marine Industries
Smartboost
Portable Boost
• Provides a 15% AC voltage boost
• Unique “portable” dockside boosting
to any existing 50 Amp straight
transformers when dockside power
drops below 210 VAC
• Rugged high quality construction
• Fully automatic operation with
manual 1:1 override
module that increases incoming
dockside power by 13%
• Designed for marinas where fluctu-
ating power is an issue, and for those
wired only for 208V
• Includes Soft Start Technology (SST)
• Low voltage, boost & power
LED indicators
Item Number
SMART BOOST
Dimensions in" (mm) HxWxD Weight in lbs. (kg)
Input Voltage
PORTABLE BOOST
Input Current
Output Voltage 50 A
200-250 VAC Price
Smart Boost
93-SMTBST50-A
9(228.6) x 12.72(323.09) x 12.69(322.33) 50(22.68)
Item Number
Input Voltage
177-240 VAC
Input Current
Output Voltage $2,444.44
Price
Portable Boost
93-SHOREBOOST-A
180-223 VAC
Item Number
50 A
208-223 VAC
Description
$2,888.89
Price
Accessories
93-SMTBREMOTE-A
SmartBoost Remote
$248.89
*See also Shore Power Boost Equipment
Images are representative of products listed and may not be actual product.
276
www.wardsmarine.com
Transformers
BUCK-BOOST
LIGHTING
ACME Buck-Boost
• Multiple Input/ Output Voltage Combinations
• Small and Compact
• UL Listed
• Raise Voltage from 5-20%
• Quiet Operation
T-1 SERIES
Item Number
KVA
Dimensions in" (cm) HxWxD Weight in lbs. (kg)
Secondary Volts 12v/24v
Price
120 x 240 Primary Volts, 12/24 Secondary Volts, 60 Hz.
T-1-81047
.05
6.41(16.3) x 3.14(8) x 3.05(7.7) 4(1.8)
4.16/2.08
$121.48
T-1-81048
.10
7.16(18.2) x 3.89(9.9) x 3.67(9.3)
5(2.3)
8.32/4.16
$141.47
T-1-81049
.15
7.16(18.2) x 3.89(9.9) x 3.67(9.3)
7(3.2)
12.52/6.25
$151.17
T-1-81050
.25
8.68(22) x 4.08(10.4) x 3.88(9.9)
10(4.5)
20.80/10.40
$172.93
T-1-81051
.50
9.06(23) x 4.37(11.1) x 4.2(10.7)
15(6.8)
41.60/20.80
$216.09
T-1-81052
.75
9.68(24.6) x 4.75(12.1) x 4.51(11.5)
19(8.6)
62.50/31.25
$306.89
T-1-11683
1
10.5(26.7) x 5.5(14) x 5.13(13)
24(10.9)
83.20/41.60
$359.92
T-1-11684
1.5
11.62(29.5) x 5.5(14) x 5.13(13)
30(13.6)
125/62.5
$432.49
T-1-11685
2
13(33) x 5.5(14) x 5.13(13)
38(17.2)
166/83.20
$564.52
T-1-11686
3
11.50(29.2) x 10.31(26.2) x 7.13(18.1) 55(24.9)
250/125
$856.83
Electronic: Halogen/Zenon
• UL Listed & CSA Certified
• Auto Reset thermal cut off 125˚C
• Aluminum Casing
• Dimmable
• Waterproof potting
• Designed to power low voltage
(12V or 24V) Halogen or Xenon lamps
LET75
Item Number
Dimensions in" (mm) LxWxD
Weight in oz.
Max Load
Output Volts
Price
LET75
2.09(53.08) x 1.29(32.76) x .78(19.81)
3
75W
11.75V, 40 kHz.
$24.00
LET75-24V
2.09(53.08) x 1.29(32.76) x .78(19.81)
3.5
75W
23.2, 40kHz.
$28.40
LET105
.88(22.35) x 1.375(34.92) x 3.125(79.37)
4.92
105W
11.8, 30kHz.
$33.00
LET151
1.375(26.92) x 1.5(38.10) x 6.5(165.10)
5.96
150W
11.8, 30kHz.
$52.00
LET151-24V
1.375(26.92) x 1.5(38.10) x 6.5(165.10)
6
150W
23.4, 30kHz.
$56.00
Input Volts 120, 60 Hz.
Images are representative of products listed and may not be actual product.
www.wardsmarine.com
277
Transformers
LIGHTING
Magnetic
• No RFI disturbances
• Double Insulated
• Internal thermal overload protection
• Current and short circuit protection
• High efficiency
Item Number
Input
Volts
• BT: Cylinder shaped transformer is encapsulated in
self extinguishing plastic case with removable cover
over four wire attachment lugs.
• CBX: Cylinder shaped transformer is encapsulated in
self extinguishing plastic case with four 6” wire leads
extending for easy hook up.
Output
Volts
Capacity
VA
Dimensions in" (mm) HxW
Weight in lbs. (kg)
Type
Price
60 Hz. Input and Output
130020-A
120
12
20
2-5/16(63.906) x 1-1/78(29.921)
1(.45)
CBX
$94.20
130050-A
120
12
50
2-7/16(68.986) x 2-3/8(60.452)
1.5(.68)
CBX
$106.80
130050-D
230
24
50
2-7/16(68.986) x 3-3/8(85.852)
1.5(.68)
CBX
$106.80
130080-A
120
12
80 3-3/16(84.226 x 2-3/4(59.436)
2.5(1.13)
CBX
$113.33
130100-D
230
24
100
3-1/8(80.772) x 2-9/16(74.066)
3(1.36)
CBX
$126.46
130105-E
120
12
105
3-1/4(79.756) x 3-5/8(90.932)
3(1.36)
BT
$128.70
130150-A
120
12
150 3-1/4(79.756) x 3-1/8(80.772)
3.25(1.47)
CBX
$146.55
130150-H
230
24
150
3-1/4(79.756) x 4-1/2(114.300)
3.25(1.47)
BT
$193.98
130200-A
120
12
200
3-7/8(96.012) x 3-1/4(79.756)
3.5(1.59)
CBX
$228.03
130200-D
230
24
200
3-7/8(96.012) x 3-1/4(79.756)
3.5(1.59)
CBX
$148.56
The following are guidelines from the American Boat and Yacht Council (ABYC) standard E-11.9
Isolation of Galvanic Current, Ward’s Marine Electric recommends installation to always be in
accordance with the ABYC standards and to be done by a certified licensed marine electrician.
11.7.1. Isolation Transformers - If used, an isolation transformer shall be of the encapsulated
type and shall meet the requirements of UL 1561, Dry Type General Purpose and Power
Transformers and the following additional requirements.
11.7.1.4. The transformer case is to be metallic with a grounding terminal provided.
11.7.1.5. The transformer shall be tested and labeled by an independent laboratory to
establish compliance with the requirements of ABYC E-11.7.1.
* Call for detailed information on our Service Products or to schedule an appointment.
Images are representative of products listed and may not be actual product.
278
www.wardsmarine.com
Download