Technical Information Manual Revision n.1 29 January 2010 MOD. NV8020 NPO: 00109/09:CNMVM.MUTx/01 7U CRATE 6 SLOT VME64 5 SLOT NIM CAEN Technologies will repair or replace any product within the guarantee period if the Guarantor declares that the product is defective due to workmanship or materials and has not been caused by mishandling, negligence on behalf of the User, accident or any abnormal conditions or operations. CAEN Technologies declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on behalf of the User. It is strongly recommended to read thoroughly the CAEN User's Manual before any kind of operation. CAEN Technologies reserves the right to change partially or entirely the contents of this Manual at any time and without giving any notice. Disposal of the Product The product must never be dumped in the Municipal Waste. Please check your local regulations for disposal of electronics products. Document type: User's Manual (MUT) Title: NV8020 - VME/NIM 7U crate, 6 slot VME64 400W, 5 slot NIM 150W PRELIMINARY Revision date: Revision: 29/01/2010 1 TABLE OF CONTENTS 1. GENERAL DESCRIPTION.........................................................................................................................4 1.1 2. 3. TECHNICAL SPECIFICATIONS..............................................................................................................5 2.1 TECHNICAL SPECIFICATION TABLE ...........................................................................................................5 2.2 MAINS VOLTAGE AND CONNECTION ........................................................................................................5 VME SECTION.............................................................................................................................................8 3.1 BACKPLANE MECHANICAL DESIGN ..........................................................................................................8 3.1.1 Climatic Parameters........................................................................................................................8 3.1.2 Mechanical Parameters...................................................................................................................8 3.1.3 Electrical parameters ......................................................................................................................8 3.2 4. OVERVIEW ...............................................................................................................................................4 POWER SUPPLY SPECIFICATIONS ..............................................................................................................9 NIM SECTION............................................................................................................................................11 4.1 THE MOD. N8315 LINEAR POWER SUPPLY .............................................................................................11 4.1.1 Power supply installation ..............................................................................................................11 LIST OF FIGURES FIG. 1.1: THE MOD. NV8020 CRATE ....................................................................................................................4 FIG. 2.1: MOD. NV8020 TECHNICAL DRAWING (FRONT, NIM POWER SUPPLY NOT PRESENT)..............................6 FIG. 2.2: MOD. NV8020 TECHNICAL DRAWING (BACK).......................................................................................6 FIG. 2.3: MOD. NV8020 TECHNICAL DRAWING (SIDE).........................................................................................7 FIG. 2.4: MOD. NV8020 FRONT PANEL WITH ON/OFF SWITCH AND VME +5V / ±12V LEDS .............................7 FIG. 3.1: VME CPCI POWER SUPPLY ...................................................................................................................9 FIG. 4.1: MOD. N8315 LINEAR POWER SUPPLY ..................................................................................................11 FIG. 4.2: MOD. N8315 POWER SWITCH AND STATUS LED ...................................................................................11 FIG. 4.3: MOD. N8315 BACKPLANE NIM CONNECTORS .....................................................................................12 LIST OF TABLES TABLE 2.1: MOD. NV8020 TECHNICAL FEATURES ..............................................................................................5 TABLE 2.2: HIRSCHMANN CONNECTOR CABLING..................................................................................................5 TABLE 3.1: VME POWER SUPPLY TECHNICAL SPECIFICATIONS ...........................................................................9 TABLE 4.1: MOD. N8315 LINEAR POWER SUPPLY TECHNICAL SPECIFICATIONS ................................................12 NPO: 00109/09:CNMVM.MUTx/01 Filename: NV8020_REV1.DOC Number of pages: 12 Page: 3 Document type: User's Manual (MUT) Title: NV8020 - VME/NIM 7U crate, 6 slot VME64 400W, 5 slot NIM 150W PRELIMINARY Revision date: Revision: 29/01/2010 1 1. General description 1.1 Overview The CAEN Mod. NV8020 is a 19” x 7U 84TE mixed VME / NIM crate equipped with a 1U common fan unit. The VME section features 6 slots suitable for 6Ux160mm boards, with VME64/VME64x compliant backplane. The section is powered by universal AC input switching Power Supply (6U 8TE). The Power distribution is 50A@+5V, 1.5A@-12V, 7.5A@+12V. The NIM section consists of 7 NIM slots (5 free) provided with pluggable 150W power supply. The Unit is powered by 110 or 220 Vac, 50 ÷ 60 Hz. On the front panel the status of power supply is indicated by green/red LED. The Unit is powered by 220 Vac or 115 Vac, 50 ÷ 60 Hz.. Power supply must be disconnected any time the unit is serviced. The Mod. NV8020 is an equipment for BUILDING-IN. Fig. 1.1: The Mod. NV8020 crate NPO: 00109/09:CNMVM.MUTx/01 Filename: NV8020_REV1.DOC Number of pages: 12 Page: 4 Document type: User's Manual (MUT) Title: NV8020 - VME/NIM 7U crate, 6 slot VME64 400W, 5 slot NIM 150W PRELIMINARY Revision date: Revision: 29/01/2010 1 2. Technical specifications 2.1 Technical specification table Table 2.1: Mod. NV8020 Technical Features Mechanics 19” x 7U 84TE mixed crate VME64 (6 slots for 6Ux160mm boards) / NIM (5 free slots); 1U common fan unit Mains input 230 VAC or 115 VAC, 50-60 Hz Fuse 1 External 16 A, type B/C 1 External 2 A, class T (230 VAC) Isolation CE acc. to EN 61010 Efficiency 75% ÷ 85% @ 230 Vac configuration dependent Section VME64 NIM Backplane J1/J2, VME64X J1/J2 – J1/J0/J2 Automatic daisy chain, CBLT compliant Equipped with long-life NIM connectors Max Total Output Power 400W 150W Output power 50A@+5V, 1.5A@-12V, 7.5A@+12V 5 A @ ±6V 3 A @ ±12 V 1.5 A @ ±24 V Load Regulation < 10 mV for 0-100% load change @ +5 V, < 15 mV for 0-100% load change @ ±12 V < 0.5 % for 10-100% load change, < 0.02 % for ±10% line change Noise and ripple (backplane connector) +5V: 100 mVpp +3.3V: 60 mVpp ±12V: 120 mVpp ±6V < 5 mVpp ±12 V < 8 mVpp ±24 V < 10 mVpp Power supply type Telkoor Compact PCI 6U 8HP 400 Watt AC power supply (see § 3.2) CAEN Mod. N8315 (see § 4.1) 2.2 Mains Voltage and Connection The Power supplies are equipped with a “World”- mains input, which works properly form 94VAC up to 264VAC and within a frequency range of 47 to 63Hz. Before connecting to the mains please double-check correspondence. Mains input connection at the power supply side is done with a 3-pin “Hirschmann” 16 A connector or power terminals. Table 2.2: Hirschmann connector cabling Hirschmann pin nr. Signal Description Color of the Wire Pin 1 L Phase black or brown Pin 2 N Return, Neutral blue Pin 3 Earth not connected PE Protective Earth green/yellow In order to turn on the unit: • Connect mains plug to 150W NIM Linear Power Supply • Switch On the 150W NIM Linear Power Supply (see § 4.1) • Switch On the NV8020 crate via the front panel with ON/OFF switch NPO: 00109/09:CNMVM.MUTx/01 Filename: NV8020_REV1.DOC Number of pages: 12 Page: 5 Document type: User's Manual (MUT) Title: NV8020 - VME/NIM 7U crate, 6 slot VME64 400W, 5 slot NIM 150W PRELIMINARY Revision date: Revision: 29/01/2010 1 Fig. 2.1: Mod. NV8020 Technical Drawing (front, NIM power supply not present) Fig. 2.2: Mod. NV8020 Technical Drawing (back) NPO: 00109/09:CNMVM.MUTx/01 Filename: NV8020_REV1.DOC Number of pages: 12 Page: 6 Document type: User's Manual (MUT) Title: NV8020 - VME/NIM 7U crate, 6 slot VME64 400W, 5 slot NIM 150W PRELIMINARY Revision date: Revision: 29/01/2010 1 Fig. 2.3: Mod. NV8020 Technical Drawing (side) Fig. 2.4: Mod. NV8020 front panel with ON/OFF switch and VME +5V / ±12V LEDs NPO: 00109/09:CNMVM.MUTx/01 Filename: NV8020_REV1.DOC Number of pages: 12 Page: 7 Document type: User's Manual (MUT) Title: NV8020 - VME/NIM 7U crate, 6 slot VME64 400W, 5 slot NIM 150W PRELIMINARY Revision date: Revision: 29/01/2010 1 3. VME Section The VME section of the NV8020 Crate has 6 slots suitable for 6U boards, with VME64 or VME64x compliant backplane. The section is powered by universal AC input switching Power Supply (6U / 8TE). 3.1 Backplane Mechanical Design The VMEbus is designed for 19-inch rack technology and supports bus lengths of up to 21 slots. In this system, slot 1 is the leftmost, with the rest of the bus extending to the right. VME Backplane technical features - Monolithic (VME64 J1/J2, VME64X J1/J2, VME64X J1/J0/J2) - 6 slot - 10 layers - Strip line technology for maximum data rates (320Mbyte/s, 64bit) - Actively terminated - Electrical automatic daisy chain - CBLT Compliant 3.1.1 Climatic Parameters Operating temperature –40°C to +85°C Storage temperature –55°C to +85°C Climatic conditions according IEC 68/1: 25/085/21 3.1.2 Mechanical Parameters Flammability - PCB: UL 94 V-0 - Connectors: UL 94 V-0/–1 Vibration - According to DIN 41640 Part 15: 10 Hz ÷ 500 Hz 5 g rms - Impact (10 Impacts per axis x,y,z) 100 g, 6 ms Connectors DIN 41612, C96 type, class 2 with 400 connection cycles 3.1.3 Electrical parameters Compliant to VMEbus Specification ANSI/VITA 1-1994 Maximum data transfer rate 80 Mbyte/s for MBLTprotocol and 160 Mbyte/s for 2e-protocol Ohmic resistance of signal lines < 60 mOhm/Slot NPO: 00109/09:CNMVM.MUTx/01 Filename: NV8020_REV1.DOC Number of pages: 12 Page: 8 Document type: User's Manual (MUT) 3.2 Title: NV8020 - VME/NIM 7U crate, 6 slot VME64 400W, 5 slot NIM 150W PRELIMINARY Revision date: Revision: 29/01/2010 1 Power Supply specifications Fig. 3.1: VME CPCI Power Supply CPCI power supply delivering 400W continuous power. Compliant with the PICMG 2.11. using 2 converters in parallel – one for the 3.3V and one for the 5V enable max. current draw on the two outputs together. Table 3.1: VME Power Supply Technical specifications Input AC Input Voltage 85÷264 VAC, auto range, single phase Input Inrush Current 50A max @230 VAC Input Reflected Ripple EN55022 Class B with the use of an external line filter Active Power Factor Correction 0.98 typ. at 230Vac, full load 0.99 typ. at 115Vac, full load Efficiency @ 230VAC Full Load >80% typical at 230Vac, full load rated power Efficiency @ 115VAC Full Load >76% typical at 120Vac, full load rated power Input Line Protection Internal Line Fuse: IEC type, 8A 250Vac quick acting Hold-up Time 16mSec typical at full load and 220VAC input Output V1 / Current +5VDC / 50A V2 / Current +3.3VDC / 80A V3 / Current +12VDC / 7.5A V4 / Current -12VDC / 1.5A Total Output Power 400W with 250LFM forced air cooling Line Regulation ± 0.5% Hot-Swap Yes Current Share Single Wire – on V1 & V2 Remote Sense (Open sense lines protected) On +5VDC & +3.3VDC Over-Voltage Protection 110% - 130% of V1, V2 & V3 with Latched Shut Down Short Circuit Protection Available on all outputs Temperature Protection Excess Temp will shut down the unit – with Auto Recovery Load Regulation V1 & V2 ± 1% V3 ± 4% V4 ± 4% With minimum load on 10A on the 3.3V output Min. Load Requirement No Overshoot / Undershoot at Turn-on Less than 1% Turn-on Delay 1 Sec Max. Initial Setting Accuracy ± 1% NPO: 00109/09:CNMVM.MUTx/01 Filename: NV8020_REV1.DOC Number of pages: 12 Page: 9 Document type: User's Manual (MUT) Title: NV8020 - VME/NIM 7U crate, 6 slot VME64 400W, 5 slot NIM 150W Voltage Set Point (Internal trim-pot) V1 / V2 PRELIMINARY Revision date: Revision: 29/01/2010 1 ± 4% Ripple @ Noise with 20MHz Bandwidth across 120μF Load Cap. // with 1μF Ceramic Cap. V1 100mV p-p V2 60mV p-p V3 & V4 120mV p-p Overload Protection V1 & V2 130% Max. V3 & V4 200% Max. Environmental Temperature Operation -5ºC to +55ºC with 300LFM Forced Air Cooling Storage -40ºC to +85ºC Humidity Up to 95% RH Non-Condensing Shock & Vibration Shock: Peak acceleration 10GPK max. Vibration: Random vibration, 10Hz to 500Hz, 3 axis 1.9GRMS max. Conducted & Radiated Emission EN55022/CISPR22 Class B with an external TBD line filter EN61000-4-5 MTBF 400,000 Hours per Belcore Standard B332 Gb 30º Dielectric Isolation Input to Case 1500Vdc. Input to Output 3000Vdc. Output to Case 100Vdc. Safety, Regulations and EMI Specifications Safety Approvals UL60950, EN60950 & CE marking Dielectric Withstand Voltage 1500VDC Input to Output, 3000VDC Input to Chassis Ground ESD Susceptibility EN61000-4-2 level 4 8KV air Radiated Susceptibility EN61000-4-3 level 3 10V/m EFT / Burst EN61000-4-4 level 3 ±2KV Input Surge EN6100 -4-5 level 3 line-to-line 1KV line to chassis 2KV Conducted Disturbance EN61000-4-6 level 2 3Vrms Power frequency magnetic field EN61000-4-8 3A/m Monitoring Command & Control Inhibit TTL Compatible Power FAIL (Fit #) TTL Compatible Current Share On V1 & V2 Allows ± 10% Current Share with a Similar Unit DEG # Open Collector Activated LOW 10ºC before Thermal ShutDown Input AC Connector Standard PICMG 47 Pin Positronics Remote Sense On V1 & V2 for Cable Loss Correction of up to 200mV Output Connectors V1/ V2 Standard PICMG 47 Pin Positronics Output Connectors V3/ V4 Standard PICMG 47 Pin Positronics I²C Data Bus (optional) Yes for Pre-Programmed Static Parameters Front Panel Green LED Inputs OK Front Panel RED LED Output Failure Mechanical Dimensions Size 6U High 8HP wide 169.6 mm Deep Weight 1500 gr NPO: 00109/09:CNMVM.MUTx/01 Filename: NV8020_REV1.DOC Number of pages: 12 Page: 10 Document type: User's Manual (MUT) Title: NV8020 - VME/NIM 7U crate, 6 slot VME64 400W, 5 slot NIM 150W PRELIMINARY Revision date: Revision: 29/01/2010 1 4. NIM Section The NIM section of the NV8020 Crate consists of 7 NIM slots: five free and two reserved for the pluggable power supply. 4.1 The Mod. N8315 Linear Power supply Fig. 4.1: Mod. N8315 Linear Power Supply The Mod. N8315 is a 150W NIM Linear Power supply, suitable to any NIM crate. Safety features include: short circuit protection, Over/Undervoltage protection, Over temperature protection. The Unit is powered by 115 or 230 Vac, 50 ÷ 60 Hz. On the front panel the status of the power supply is indicated by green/red LED. In order to switch from 230 VAC to115 VAC, it is necessary to place the switches on the Crate from 230V to 115V position, and replace the External 2 A Fuse with an External 4A, class T (115VAC). This operation MUST be performed with the Crate disconnected from the Mains. Fig. 4.2: Mod. N8315 Power switch and Status led 4.1.1 Power supply installation The power supply unit has to be plugged frontally in the two slots at the right side (slot 6 and 7). The backplane is equipped with high-quality long-life NIM connectors, which are completely parallel-wired. The connector foreseen for the power supply unit (slot 7) has additional paralleled voltage pins. Before turning on the crate, it is necessary to verify that the power plug is connected to the N8315 Linear Power supply (see § 2.1). NPO: 00109/09:CNMVM.MUTx/01 Filename: NV8020_REV1.DOC Number of pages: 12 Page: 11 Document type: User's Manual (MUT) Title: NV8020 - VME/NIM 7U crate, 6 slot VME64 400W, 5 slot NIM 150W PRELIMINARY Revision date: Revision: 29/01/2010 1 0V=POWER SUPPLIES RETURN (GND) E=HIGH QUALITY GND (EARTH) Fig. 4.3: Mod. N8315 Backplane NIM connectors Table 4.1: Mod. N8315 Linear Power Supply Technical Specifications Mechanics 2 unit NIM module Mains input 230 VAC or 115 VAC, 50-60 Hz Max Total Output Power 150 W Fuse External External 2 A, class T (230 VAC) Output power 5 A @ ±6V ; 3 A @ ±12 V ; 1.5 A @ ±24 V Load Regulation < 0.5 % for 10-100% load change, < 0.02 % for ±10% line change; ±6V: <30 mV for 10-100% load change, <1mV for ±10% line change; ±12 V: <60 mV for 10-100% load change, <2mV for ±10% line change;±24V: <120 mV for 10-100% load change, <5mV for ±10% line change Isolation CE acc. to EN 61010 Ripple ±6V < 5 mVpp ; ±12 V < 8 mVpp ; ±24 V < 10 mVpp Transient response recovery 0.15 ms for recovery to ±1% of voltage for 10-100% load change Output Impedance 0.6 mohm static Output Voltage Characteristic dual tracking for all ±DC outputs; Soft start; DC output calibration (manually) Output Current Characteristic OVC protection / Trip Off Over Voltage Protection Trip Off when the output voltage > 130% of nominal voltage Under Voltage Protection Trip Off when the output voltage < 70% of nominal voltage Over Current Protection Trip Off when current: > 2 A @ ±24 V, > 4 A @ +12 V, > 3.5 A @ -12 V, > 6 A @ ±6V Over Temperature Protection Trip Off when temperature > 75° C Temperature sensors nr.1 Status control Fail/Status LED signal Switches Power 1 (On) / 0 (Off) Operation 0÷45°C without derating NPO: 00109/09:CNMVM.MUTx/01 Filename: NV8020_REV1.DOC Number of pages: 12 Page: 12