AC Power Solutions Outdoor Uninterruptible Power Supplies Indoor Uninterruptible Power Supplies Backup Power Solutions Enclosures Batteries Generators Accessories Custom Solutions About Alpha Alpha Technologies Ltd. Alpha Technologies Ltd. develops, manufactures and markets indoor and outdoor UPS and AC Backup Power solutions and provides market specific products for the Telecom, DataComm, Traffic, Parking, Medical, and Security markets. Alpha also works in partnership with globally recognized companies to provide customized OEM solutions. Alpha products and solutions are known for their high-quality, feature-rich systems that are engineered to meet industry requirements and withstand harsh environmental conditions. Sales, service, and maintenance is available through a network of dedicated centers worldwide 24/7. Alpha Technologies Ltd. is a member of The Alpha Group. The Alpha Group The Alpha Group represents an alliance of independent companies who share a common philosophy – to create world class Total Power Solutions. Collectively, The Alpha Group is a leader in the power industry with thirty years of outdoor power expertise, and over two million systems installed globally. Its members develop and manufacture AC and DC power conversion, protection, and standby products. Applications for these products include broadband, telecom, AC/UPS, commercial, industrial, and distributed generation, for a worldwide customer base. Alpha Group companies also provide a range of installation, service and maintenance services. Members of The Alpha Group include Alpha Technologies Inc., Alpha Technologies Ltd., Alpha Energy, Alpha Industrial Power, Argus Technologies, and G.B. Enterprises. Table of Contents Power Solutions for Outdoor and Harsh Environments.......................................... 3 Novus FXM.................................................................................................................. 4 Communications and Monitoring................................................................................. 5 Novus Micro Secure 100.............................................................................................. 6 Alpha Novus Micro, Micro XL, Micro XL3.................................................................... 7 Transfer and Bypass Switches..................................................................................... 8 Batteries and Accessories....................................................................................... 9 AlphaCell™ Gold and GXL......................................................................................... 10 AlphaCell™ AGM....................................................................................................... 12 AlphaCell™ FT........................................................................................................... 13 AlphaCell™ SMU HR................................................................................................. 14 Battery Accessories................................................................................................... 15 Generators............................................................................................................. 17 AlphaGen™ DCX 3000.............................................................................................. 18 AlphaGen™ Curbside................................................................................................ 19 Enclosures............................................................................................................. 21 Alpha Outdoor Enclosure Side Mount 6.................................................................... 22 Alpha B4.................................................................................................................... 23 Flextra P Series.......................................................................................................... 24 Flextra U Series.......................................................................................................... 25 Flextra Z Series.......................................................................................................... 26 Flextra Node.............................................................................................................. 27 Radium Mini Bay........................................................................................................ 28 Indoor Solutions.................................................................................................... 29 Indoor UPS Topology................................................................................................. 30 ALI Elite...................................................................................................................... 32 ALI Elite XL................................................................................................................. 34 ALI Elite Extended Run Time Battery Pack................................................................ 35 Pinnacle Plus............................................................................................................. 36 Pinnacle Plus High Power.......................................................................................... 38 CFR............................................................................................................................ 40 AlphaMED®............................................................................................................... 43 Comet........................................................................................................................ 45 Galaxy 4000............................................................................................................... 47 Galaxy 3000............................................................................................................... 49 Electrical Receptacles........................................................................................... 51 Service................................................................................................................... 52 Uninterruptible Power Supply Selection Guide..................................................... 53 Alpha AC Catalogue 2008 For Prin1 1 7/30/2008 3:02:14 PM Alpha AC Catalogue 2008 For Prin2 2 7/30/2008 3:02:14 PM Power Solutions for Outdoor and Harsh Environments Alpha Technologies Ltd. specializes in providing AC power solutions for harsh environments. With over 30 years of experience in the global outdoor market, Alpha is positioned as the leader in providing rugged AC powering solutions, including hardened outdoor enclosures, uninterruptible power supply (UPS) modules, specialty batteries, battery accessories and generators to a large and recognizable customer base. A truly rugged UPS system has many unique characteristics including conformal coated PCBs which protect against exposure to moisture, high levels of humidity and dust, carefully selected components to operate fully in extreme temperatures and boards designed to minimize environmental impact. In addition, products and solutions are designed to meet, outdoor installation, shock and vibration, standards. Systems must be designed to operate under extreme temperature conditions. Because Alpha understands these requirements, the Novus line of outdoor products is capable of withstanding extreme temperatures. Alpha’s powering solutions also offer superior communications capabilities including remote monitoring via SNMP web-based communication. Real-time alerts and reports on UPS status can be sent to four different email addresses, or can be monitored from your PC, Internet-connected mobile phone or PDA, each with selectable event severity levels to trigger different notifications of events, faults and alarms. Alpha’s power solutions for harsh environments have been used across the world for the last 30 years, operating with great reliability to ensure that mission-critical applications remain working even in times of unstable and unreliable power. Alpha AC Catalogue 2008 For Prin3 3 7/30/2008 3:02:14 PM Outdoor Solutions Novus FXM 650, 1100, 2000 Clean, uninterruptible backup power ensures your system will remain running during power outages Wide range Automatic Voltage Regulation without going to batteries lengthens battery life, even during periods of surge or sag in the line voltage External communications via RS-232 port or (optional) Ethernet SNMP interface provides local or remote monitoring and control Independently programmable and dry contact relays allow tracking and controlling of key functions Alpha Novus FXM Event and alarm logging with time and date stamping simplifies and accelerates troubleshooting A wide operating temperature range of -40º to 74ºC (-40º to 165ºF) is suitable for the most extreme operating environments Control and power connection panels can be rotated for mounting and display in any orientation for viewing convenience Temperature compensated battery charging protects batteries from over charging at extreme temperatures, extending the life of the battery Outdoor Solutions Novus FXM power modules provide constant, reliable UPS grade backup power management for Traffic, Security, Telecommunications and other applications. The FXM can operate in temperatures of -40°C to 74°C (-40°F to 165°F) supporting your mission critical applications with clean, uninterruptible power. The FXM modules are CSA and UL approved and are adaptable for vertical1 or horizontal orientations as well as rack mounting. Double buck and Double boost is designed into the module to accept a wider input range, providing constant output voltage without switching to system batteries. The FXM’s built-in communications intelligence software reports UPS event status, collects valuable planning and maintenance data, and monitors your site, through a Windows-based GUI. It also offers a real-time clock for statistical analysis and event diagnostics. An optional SNMP Ethernet interface is available for remote monitoring from virtually any internet-supported location. Specifications Power Module: FXM 650 FXM 1100 FXM 2000 North America International North America International North America International Battery String Voltage: 24VDC/48VDC 24VDC 48VDC 48VDC 48VDC 48VDC Nominal Voltage: 120VAC 230VAC 120VAC 230VAC 120VAC 230VAC Nominal Frequency: auto-sensing Input Current: 8.7A 4.5A 15.5A 8.0A 20.0A 32A Input Voltage Range: 85-175VAC 150-328VAC 85-175VAC 150-328VAC 85-150VAC 150-281VAC Output Current: 5.8A 3.0A 9.9A 5.1A 17.9A 9.4A 650W/VA 650W/VA 1100W/VA 2000W/VA 2000W/VA Output Voltage Regulation +/- 10% over input voltage range Output power at 50°C: WxHxD Weight 1100W/VA 17”x3.47”x9” 15.5”x5.22”x8.75” 15.5”x5.22”x8.75” 432x88x229mm 394x133x222mm 394x133x222mm 25lb/30lb for 48V 35lb 35lb 11kg 16kg 16kg Agency Compliance Electrical safety: UL1778, CSA 22.2 No 107.3-03 Marks: C CSAUS /CE* EMI: Class A FCC/CISPR [EN 50091-2:1995] Alpha AC Catalogue 2008 For Prin4 4 *CE applies to 230 VAC version only 7/30/2008 3:02:14 PM Outdoor Solutions Communications and Monitoring Ethernet/SNMP Card Option Novus FXM, Novus Micro, Novus Micro Secure For greater effectiveness, control and communication over your UPS system, choose the Ethernet/SNMP card option that is available for our Novus FXM, Novus Micro and Novus Micro Secure products. The Ethernet/ SNMP card is factory installed allowing for communication with the Alpha UPS remotely through a web based interface. The Ethernet/SNMP card is powered by the UPS batteries eliminating the need for an external power source. The communication card is capable of providing notifications to four different email addresses and to devices such as your PC, a mobile phone or PDA. Outgoing notifications can be customized with selectable severity levels and triggered by events, faults and/or alarms. Novus User Software Outdoor Solutions User’s PC (using Web browser) SNMP Server Internet Intranet On-Site Ethernet Connection Crossover Cable User’s PC (using Web browser for Ethernet connection to on-site computer) Ethernet Port FXM Monitor Card FXM UPS Novus User Software is a graphical user interface (GUI) designed to help Alpha UPS users monitor, control and set various parameters for their UPS systems through a computer using a standard RS-232 connection or through the internet when the UPS is equipped with an Ethernet/SNMP card. Users are able to read and display UPS events, warnings, date, time and relay configurations through this Windows-based environment. The software is an excellent maintenance and troubleshooting tool that automatically updates information every five seconds and records events and warnings with time/date stamps. Get real-time notification of every alarm and fault that occurs so that you are immediately in a position to take action. Easy to customize to your exact needs, the Ethernet edition allows you to set your own notification preferences via PC and receive notifications to any PC, mobile phone, PDA, or any device that accepts email. Alpha AC Catalogue 2008 For Prin5 5 7/30/2008 3:02:15 PM Outdoor Solutions Novus Micro Secure 100 All weather protection with durable outdoor NEMA 3R rated plastic enclosure Enhanced battery life with wide-range Automatic Voltage Regulation Local or remote monitoring and control through RS-232 port or (optional) SNMP Ethernet interface Tracking and controlling of key functions through independently programmable relays Alpha Novus Micro Secure 100 Simplified troubleshooting through event and alarm logging with time and date stamping Maximum mounting flexibility for accommodation of space requirements1 The Novus Micro Secure provides constant, reliable backup power for small critical load applications such as security cameras, surveillance systems, WiFi equipment and outdoor lighting. With its NEMA 3R enclosure, this easy-to-install solution includes a UPS power module and battery bank for an all-in-one out-of-the box solution: just wire the inputs, your load and communications (if ordered), and it’s ready for operation. Due to its compact design and light weight, the Micro Secure can be wall or pole mounted (when using the optional pole mounting bracket). The Micro Secure can also be used as a power supply for security camera applications. An optional Ethernet/SNMP interface is available. 1 Mounting brackets sold separately Novus Micro Secure Electrical safety: North America International Battery String Voltage 24VDC 24VDC Marks: EMI: EN60950 Nominal Voltage 120VAC 230VAC Nominal Frequency 60Hz 50Hz Input Current 2.0A 1.0A Input Voltage Range 85 – 150VAC 154 – 323VAC Output Current 0.83A @ 120VAC 4.2A @ 24VAC 0.43A @ 230VAC 230VAC 4.2A @ 24VAC 60Hz 50Hz WxHxD 15”x11.5”x6” Power Module Outdoor Solutions Agency Compliance Nominal Specifications UL1778, CSA 22.2 No. 107.1 CSAUS , CE* Class A FCC/CISPR, EN50091-1-2, C *CE applies to 230VAC version only 381x292x152mm Weight (with 4 9Ah batteries) 45lb / 20.4kg Run Time* 2 hrs 15 mins * Run time on battery power can vary based on loads, temperature and battery. Other battery options are available. Alpha AC Catalogue 2008 For Prin6 6 7/30/2008 3:02:19 PM Outdoor Solutions Alpha Novus Micro, Micro XL, Micro XL3 Clean, uninterruptible backup power ensures your system will remain up and running during power outages Wide range Automatic Voltage Regulation without going to batteries extends battery life, even during periods of surge or sag in voltage from utility power External communications via RS-232 port or (optional) Ethernet SNMP interface provides local or remote monitoring control Independently programmable control and report relays allow tracking and controlling of key functions1 User-friendly LCD display allows "at-a-glance" monitoring and troubleshooting2 Event and alarm logging with time and date stamping simplifies and accelerates troubleshooting Alpha Novus Micro 1000 A wide operating temperature range of -40º to 74ºC (-40º to 165ºF)3 is suitable for most extreme operating environments Temperature compensated battery charging protects batteries from over charging at extreme temperatures The Alpha Novus Micro line provides constant reliable backup power in 300VA or 1000VA models for use in Access Control, Security, Parking, Public Utility and Telecommunications applications. This all-in-one solution is comprised of a NEMA 3R outdoor rated enclosure, an uninterruptible power supply module and battery bank. Batteries selection is based on the application and run time requirements. Be sure to order the appropriate battery connector kit for your specific application. The Novus Micro can withstand harsh outdoor conditions operating in temperatures of -40°C to 74°C (-40°F to 165°F) to support your mission critical applications with clean, uninterruptible power. Optional Battery Heater Mats provide heat to the batteries and are recommended for optimal performance in cold climates. For extended run time applications, the XL or XL3 provide space to accommodate additional batteries. 1 This feature is available on the Novus Micro 300 model only 2 This feature is optional for the Novus Micro 300 model 3 This applies to the UPS module only. Batteries may require a heater mat at lower temperatures. Output power derates after 50ºC Power Module: Novus Micro 300 Novus Micro 1000 North America International North America International Battery String Voltage 24VDC 24VDC 48VDC 48VDC Nominal Voltage 120 VAC 230VAC 120VAC 230VAC Nominal Frequency 60Hz 50Hz 60Hz 50Hz Input Current 5.4A 2.8A 14A 7.3A Input Voltage Range 85-175VAC 150- 328VAC 85-175VAC 150- 328VAC Output Current 2.5A 1.3A 8.3A 4.3A 300W/VA 300W/VA Output Voltage Regulation Outdoor Solutions Nominal Specifications +/- 10% over input voltage range Output Power @50°C Run Time* 1000W/VA 2 x 50Ah batteries - 2 hrs 12 mins 1000W/VA 4 x 18Ah batteries - 26 mins * Run time on battery power can vary based on loads, temperature and battery. Other battery options are available. Dimensions (W x H x D) Novus Micro 14.1” x 19.7” x 11.6” 358 x 500 x 294 mm Novus Micro XL 14.1” x 30.6” x 11.6” 358 x 776 x 294 mm Novus Micro XL3 14.1” x 52.4” x 11.6” 358 x 1330 x 294 mm Weight (without batteries) 43.4 lb / 19.7 kg 49.8 lb / 19.7 kg 69.2 lb / 22.6 kg Agency Compliance Electrical safety: UL1778, CSA 22.2 No. 107.3, EN50091-1-2, EN60950 EMI: Level A FCC, CISPR22, EN55022 Marks: CSAUS , CE* C *CE applies to 230VAC version only Novus Micro Alpha AC Catalogue 2008 For Prin7 7 Novus Micro XL Novus Micro XL3 7/30/2008 3:02:23 PM Outdoor Solutions Transfer and Bypass Switches Alpha offers a range of transfer and bypass switches as part of its total power solutions package. These switches allow for power to be seamlessly migrated between utility line to battery backup or generator. Alpha Automatic Transfer Switch 120V/30A 230V/16A Alpha’s Automatic Transfer Switch acts as a fail-safe device by switching the critical load to the utility line should a fault occur in the UPS. The ATS ensures that clean power is always provided to the critical load, ensuring that your mission-critical equipment always remains running in the event of an outage. This transfer switch also includes a standard manual bypass switch which eliminates costly equipment downtime while servicing the UPS or replacing the batteries. Automatic Transfer Switch Alpha Automatic Generator Transfer Switch Outdoor Solutions 120V/30A 230V/16A Alpha’s Automatic Generator Transfer Switch automatically transfers the input to the UPS from the utility line to a portable AC generator. The GTS allows the generator to recharge the batteries and ensure your applications remain in operation during extended power outages. For manually connecting or disconnecting a generator, a standard switch is included. Automatic Generator Transfer Switch Alpha Maintenance Bypass Switch 120V 230V Option not available Alpha’s Maintenance Bypass Switch allows the user to manually bypass the UPS system for service or routine maintenance. Other Mounting Options Alpha Maintenance Bypass Switch Wall mount kit – Part number 740-756-21 Rack mount kit – Part number 593-364-P4 Mounting Options Alpha AC Catalogue 2008 For Prin8 8 7/30/2008 3:02:35 PM Batteries & Accessories Alpha offers a comprehensive line of AlphaCellTM batteries in a number of sizes and technologies to support your outdoor applications. Included in our battery line are AGM and Gel batteries that offer extended runtime and warranty configurations. Our Gel Cell batteries last longer and are more reliable because of their excellent heat displacement characteristics. Independently tested, AlphaCellTM GXL batteries come with a full replacement non-prorated warranty. These batteries have seven to eight years of expected life and trouble free performance offering reduced maintenance costs. Our AGM batteries are also available to support a variety of applications. Both models are ready with 100% out of the box capacity. In addition to our battery offerings, Alpha also has accessories to complement your battery installation or support your battery testing needs. Alpha AC Catalogue 2008 For Prin9 9 7/30/2008 3:02:35 PM Batteries AlphaCellTM Gold & GXL Valve Regulated Lead Acid (sealed) batteries Designed for indoor, outdoor standby applications 100% out-of-box runtime capacity Maintenance-free threaded inserts 100% replacement warranty Alpha offers a wide selection of sealed VRLA-AGM and VRLA-Gel batteries to provide power to a number of applications. Gel batteries provide good thermal dissipation to help ensure the best performance for you application. Alpha’s standby battery offering includes six different models incorporating four unique battery technologies, ensuring optimal performance for all outdoor powering applications. These batteries provide improved performance, longer runtimes and extended service life. AlphaCell™ Gold & GXL Batteries and Accessories 10 Alpha AC Catalogue 2008 For Prin10 10 7/30/2008 3:02:41 PM Batteries AlphaCellTM Gold & GXL General Specifications Model 215 GOLD-HP 190 GOLD-HP 210 GXL 180 GXL 165 GXL 85 GXL-HP Heat resistance Extreme Extreme High High High Extreme Terminals Threaded insert 1/4” - 20 UNC Threaded insert 1/4” - 20 UNC Threaded Insert 1/4” - 20 UNC Threaded Insert 1/4” - 20 UNC Typical Runtime (minutes) 215 190 210 180 165 85 Cells Per Unit 6 6 6 6 6 6 Voltage Per Unit 12.8 12.8 12.8 12.8 12.8 12.8 Conductance Value 1175 1100 1175 1100 1000 600 Max. Discharge Current (A) 900 900 900 900 800 600 Short Circuit Current (A) 2800 2600 2800 2600 2500 2200 10 Second Volts @ 100A 11.4 11.3 11.4 11.3 11.2 10.8 Impedance @ 60Hz (Ohms) 0.005 0.005 0.005 0.005 0.0055 0.0065 Capacity at 20hrs (to 1.75VPC) 107Ah 95Ah 106Ah 94Ah 86Ah 50Ah BCI Group Size 31 31 31 31 27 22 Mechanical Specifications Weight (lb/kg) 72/32.7 66/30 72/32.7 66/30 63/28.6 39.6/18 Height w/ Terminals (in/mm) 8.48/215.4 8.48/215.4 8.48/215.4 8.48/215.4 9.05/229.8 8.09/205.6 Width (in/mm)* 13.42/340.9 13.42/340.09 13.42/340.09 13.42/340.09 12.5/317.8 8.99/228.3 Depth (in/mm)* 6.80/172.7 6.80/172.7 6.80/172.7 6.80/172.7 6.83/173.4 5.47/138.9 Operating Temperature Range Discharge -40 to 71°C (-40 to 160°F) -40 to 71°C (-40 to 160°F) -40 to 71°C (-40 to 160°F) -40 to 71°C (-40 to 160°F) -40 to 71°C (-40 to 160°F) -40 to 71°C (-40 to 160°F) Charge (with temp compensation) -23 to 60°C (-9.4 to 140°F) -23 to 60°C (-9.4 to 140°F) -23 to 60°C (-9.4 to 140°F) -23 to 60°C (-9.4 to 140°F) -23 to 60°C (-9.4 to 140°F) -23 to 60°C (-9.4 to 140°F) Float Charging Voltage (VDC) 13.5 to 13.8 13.5 to 13.8 13.5 to 13.8VDC 13.5 to 13.8VDC 13.5 to 13.8VDC 13.5 to 13.8VDC AC Ripple Charger 0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4% P-P Threaded Insert 10-32 UNF 11 Batteries and Accessories *: Dimensions at top of battery For information on the warranties please contact your sales rep. Current Discharge Ratings Table in Amps (end Voltage 1.75VPC) Hours 1 2 3 4 6 8 10 12 20 24 48 72 100 215 Gold 67.8 40.5 29.1 22.9 16.1 12.6 10.2 8.7 5.46 4.61 Call Call Call 210 GXL 66.3 39.6 28.5 22.4 15.8 12.3 10 8.54 5.34 4.51 Call Call Call 190 Gold 64.5 37.1 26.6 20.8 14.6 11.4 9.4 7.9 4.96 4.2 2.2 1.5 1.08 180 GXL 61.2 35.2 25.2 19.7 13.9 10.8 8.9 7.5 4.7 4 2.1 1.4 1.03 85 GXL-HP 33.2 18.8 13.3 10.4 7.34 5.7 4.68 3.97 2.5 2.12 1.11 0.76 0.56 165 GXL 55.9 32.8 23.5 18.4 12.9 10.0 8.2 6.9 4.3 3.7 1.9 1.29 0.94 Alpha AC Catalogue 2008 For Prin11 11 7/30/2008 3:02:42 PM Batteries AlphaCell™ AGM Designed for indoor, outdoor standby applications 100% out-of-box runtime capacity Maintenance-free threaded inserts 100% replacement warranty Convenient carrying handle standard on all models AlphaCell™ AGM Specifications Model: 135 AGM-P 160 AGM Silver Alloy: AGM-P N/A CA/SN Alloy: N/A N/A Typical Runtime (minutes) : 135 160 Cells Per Unit: 6 6 Voltage Per Unit: 12.8 12.8 Conductance Value: 1125 1300 Max. Discharge Current (A): 800 800 Short Circuit Current (A): 3100 3300 10 Second Volts @ 100A: 11.5 11.6 Ohms Impedance 60Hz: 0.005 0.004 Capacity at 20hrs: (to 1.75VPC) 75Ah 88Ah BCI Group size: 24 27 Weight (lb/kg): 54.8/24.9 62/28 Height w/ terminals (in/mm): 8.02/203.6 9.05/229.8 4 10.26/260.5 12.57/317.8 4 6.83/173.4 6.83/173.4 -40 to 71˚C -40 to 71˚C (-40 to 160˚F) (-40 to 160˚F) 2 Batteries and Accessories 12 Width (in/mm) : Depth (in/mm) : Operating Temperature Range Discharge: Charge (with temp compensation): -23 to 60˚C (-9.4 to 140˚F) Float Charging Voltage (VDC): 13.5 to 13.8 AC Ripple Charger: -23 to 60˚C (-9.4 to 140˚F) 13.5 to 13.8 0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4% 1 2 Warranty varies by country and region. Consult your sales person for details. Runtimes calculated using a 25A DC constant current load with voltage discharge to 1.75V/cell @ 25˚C. 3 L-Type: applies to 210/180/165 GXL and AGM models. Copper Alloy 10-32 Insert: applies to 85 GXL only. Copper Alloy 1/4" insert applies to 135 GXL only. 4 Dimensions at top of battery. Alpha AC Catalogue 2008 For Prin12 12 7/30/2008 3:02:44 PM Batteries AlphaCell™ FT Front terminals with protective covers Valve regulated lead acid batteries Long life gel batteries can be used outdoors Ideal for telecom and cable applications Alpha enhances its AlphaCellTM battery family to include the sealed FT series of front terminal batteries for cable television and telecommunication applications. The AlphaCellTM FT series are designed for long life. Benefits of these new batteries include: central gassing system, hinged front covers, integral flame arrestor, recyclable lead and plastics and low self-discharge rates. These batteries come with a handle for carrying convenience. AlphaCell™ FT General Specifications Model 195 GXL-FT 225 AGM-FK Service Life Extended Extended Sealed VRLA Valve Regulated Lead acid Valve Regulated Lead acid Heat resistant High Moderate Hydrogen Emission Low Low Terminals 16mm Insert M6 thread 16mm Insert M6 thread Typical Runtime (minutes) 195 225 Cells Per Unit 6 6 Voltage Per Unit 12.8 12.8 Conductance Value 1200 1400 Max. Discharge Current (A) 400 400 Short Circuit Current (A) 3000 3100 10 Second Volts @ 100A 10.8 11.2 Impedance @ 60Hz (Ohms) 0.0041 0.0045 Capacity at 20hrs (to 1.75VPC) 110Ah 88Ah Mechanical Specifications Weight (lb/kg) 76.29/34.52 75.14/34 Height w/ Terminals (in/mm) 11.22/285 11.22/285 Width (in/mm)* 4.33/110 4.33/110 Depth (in/mm)* 15.55/395 15.55/395 Discharge -40 to 71°C (-40 to 160°F) -40 to 71°C (-40 to 160°F) Charge (with temp compensation) -20 to 50°C (-4 to 122°F) -20 to 50°C (-4 to 122°F) Float Charging Voltage (VDC) Float 2.27 to 2.30VPC @25°C cycling 2.35VPC@25°C Float 2.27 to 2.30VPC @25°C cycling 2.35VPC@25°C AC Ripple Charger 0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4% P-P 13 Batteries and Accessories Operating Temperature Range *: Dimensions at top of battery For information on the warranties please contact your sales rep. Current Discharge Ratings Table in Amps (end Voltage 1.75VPC) Hours 1 2 3 4 6 8 10 12 20 24 48 72 100 195 GXL-FT 71.1 38.0 26.8 21.1 15.2 12.0 9.92 8.48 5.50 4.60 2.31 1.56 1.13 225 AGM-FT 81.00 43.10 30.30 23.70 16.70 12.90 10.40 8.90 5.70 4.80 2.43 1.62 1.18 Alpha AC Catalogue 2008 For Prin13 13 7/30/2008 3:02:45 PM Batteries AlphaCell™ SMU-HR High Rate Discharge VRLA Battery Power range available in 12V with capacities from 9 to 135Ah Optimized grid for high power density Upright, side or end mounting Thermally welded case to cover bond eliminates leakage Optional flame retardant ABS casing to UL94-VO AlphaCell™ SMU-HR 100% replacement warranty The AlphaCell™ SMU-HR, with Absorbed Glass Mat (AGM) technology, is a high discharge rate VRLA battery specifically designed for uninterruptible power supplies, power generation, and switchgear applications. Low calcium grid alloy reduces gassing to extend battery life. This high rate discharge cycle battery is available in 12V with capacities from 9 to 135Ah. General Specifications Type Batteries and Accessories 14 Valve Regulated Lead Acid Range of Capacity 9 to 35Ah Recommended Float Voltage 13.5VPC @ 20°C (68°F) Operating Temperature Nominal 25°C (77°F) NOTE: can operate at higher temperature up to 74°C (165°F) but degrades life of battery Terminal Type Threaded Copper Insert Optional UL 94 VO Flame Retardants Casing For information on warranties please contact your sales rep. Alpha AC Catalogue 2008 For Prin14 14 7/30/2008 3:02:47 PM Battery Accessories Battery Heater Mats Low temperatures can compromise battery performance by reducing runtimes and slowing down the recharge rate. Battery Heater Mats combat these negative effects for better battery performance in cold conditions. In extreme environments, battery damage can result if battery heater mats are not used. Thermostat Specifications: Turns on when temperature falls below 5°C/41°F Turns off when temperature rises above 15°C/59°F Battery Heater Mats AlphaGuard™ Battery Charge Management System AlphaGuard™ Battery Charge Management System 15 Batteries and Accessories AG-CMT-4 AlphaGuard™ Charge Management SC, 48V String – including Battery interface cable The AlphaGuard is a battery charge management system that monitors and protects your batteries for runtime optimization and longer battery life. CSA and UL approved, AlphaGuard allows you to replace single batteries rather than the whole string. It spreads charge voltage equally across batteries to maximize battery life and compensates for battery differences as they age. Also available: AlphaGuard Potted Version for Below Grade Applications. The potted version is ideal for applications where batteries are installed under ground or subject to damp conditions or possible immersion. Note: For some applications Alpha offers an extended battery warranty when AlphaGuard is used. Contact your Alpha representative for complete details. Battery Testing Equipment Alpha’s battery testing equipment provides accurate information about the status of installed standby batteries allowing you to budget for early detection of failed or degraded batteries and for replacements with confidence. A fast, reliable and affordable testing process. Conductance testing is coupled with a simple utility load test – arms the operator with the quality of data necessary to know the status of installed standby batteries, allowing for detection and replacement before failure occurs and puts backup during an outage at risk. Alpha AC Catalogue 2008 For Prin15 15 AlphaGuard™ Potted version Celltron Essential Battery Testing Equipment 7/30/2008 3:02:52 PM Alpha AC Catalogue 2008 For Prin16 16 7/30/2008 3:02:52 PM Generators Alpha offers portable and stationary DC generators for extra long back up power runtimes. Completely enclosed and water resistant for safe operation in the field, the AlphaGen™ is quiet, convenient, and extremely economical. Its oversized metal gas tank can provide extended runtimes of up to 20 hours. Alpha AC Catalogue 2008 For Prin17 17 7/30/2008 3:02:52 PM Generators AlphaGenTM DCX 3000 Portable DC technology generator Automatic Transfer Switch (ATS) not required No need to disconnect or reconnect power supply to utility power Selectable output for 36 or 48VDC operation up to 3000W Super quiet operation only 58dBA @ 7m/22ft Alpha expands its generator line to include a portable 3.0kW DC gasoline generator. The compact, lightweight AlphaGen generator is designed specifically for powering cable television, telecommunications, broadband and traffic applications that do not have integrated generators as a primary component of the power system. DCX 3000 The portable generator incorporates several technological advantages including: 36 or 48V selectable dual voltage output based on Permanent Magnet Generator (PMG) technology, 3000W of power, and oversized fuel tank for up to 20hrs of runtime at 25% load or 7.2hrs at 100% load. Additional features include a convenient front panel with a keyed on/off switch, output connector, output indicators, voltmeter, fuel valve and engine choke. 18 General Specifications Part Number: Engine: Generators Rated Power: Alternator: 041-028-10 Honda GX 200 6.5hp, Air-cooled, OHV, Single cylinder, Manual recoil starting, Manual choke 2800W continuous, 3000W max. Permanent Magnet, brushless, bearingless Dual range selector Cable Interface: 39.5Vdc nominal at generator output connector 52.5Vdc nominal at generator output connector 1Vdc Automatic Voltage Regulation Electronic Governor Over current Protection Analog voltmeter with back light Anderson type SBE-80 connector Fuel Tank: 3.4 gallon metal tank with level gauge 36V: 48V: Output Regulation: Control Features: Runtime @ 25% Load: 20 hrs @ 80% Load: 10 hrs @ 100% Load: 7.2 hrs Noise: Approx. 58dBA @ 7m under full load Frame: Fully Enclosed Dry Weight: Less than 118lb (53.5kg) 22.4H x 18.9W x 25.8D / 569H x 480W x 655D CSA C22.2 No. 100-95, 107.1-01, 107.2M89, 0.4 FCC part 15B Class A Dimensions (in/mm): Agency: Accessories 30’ Output Interface 10’ P/N 875-324-22 30’ P/N 875-324-20 50’ P/N 875-324-21 Ring Lug Battery Interface Alligator Clamp Battery Interface P/N 874-946-20 Y-Adaptor Battery P/N 874-946-22 DCX 3000 (front view) DCX 3000 with optional Wheel Kit and Locking Handle P/N 874-946-21 Required Accessories Output Interface Cable: Battery Interface Cable: Available in 10’, 30’ or 50’ lengths Choose Ring Lung, Heavy-Duty Alligator Clamp, or Y-adapter* * Connects the power supply’s battery input directly to the generator Alpha AC Catalogue 2008 For Prin18 18 7/30/2008 3:03:02 PM Generators AlphaGen™ Curbside Cost effective extended runtime solution Quiet operation, small size, and low profile Designed for stand-alone or collocated applications Meets UL2200, NFPA 37, 54, 58 & 70 standards The AlphaGen Curbside generator system incorporates industry leading power technology to provide a stand-along power solution for curbside or remote applications. The Curbside line offers natural gas or propane powered generators, exclusive audible noise baffling, remote status monitoring features, and durable weather resistant enclosures. An optional cold start kit for extreme cold temperature is available as are enclosures for propane storage. CE-3XL General Specifications Output Rating: 3.5kW 5.0kW 7.5kW DC Output Voltage: 39.0V ±0.5V @ no load 36V config 52.0V ±0.5V @ no load 48V config 39.0V ±0.5V @ no load 36V config 52.0V ±0.5V @ no load 48V config 52.0V ±0.5V @ no load 48V config 104.0V ±0.5V @ no load 96V config 0.5V 0.5V 0.5V DC Output Load Regulation: Output Current: Engine: RPM: (Variable Speed): 39.0V @ 90A max. / 39.0V @ 128A max. / 52.0V @ 67A max. 52.0V @ 96A max. 398cc, Air cooled, Single OHV 10.5hp (using natural gas fuel) 2800 to 3600RPM 2800 to 3600RPM 52.0V @ 144A max. / 104V @ 72A max. 19 2800 to 3600RPM CE-3x2 CE-9x2 CE-3x2 CE-9x2 PN-6x Height (in/cm): Width (in/cm): Depth (in/cm): Weight (lb/kg): 44/111.2 26/66 24/61 383/174 52/132.1 52/132.1 24/61 413/187 44/111.2 26/66 24/61 383/174 52/132.1 52/132.1 24/61 413/187 39/99 (57/144 with optional pedestal) 39.25/100 24/61 338/174 (370/168 with optional pedestal) All Models Configuration Options: Gas Inlet Pressure: 0.5 to 2 PSI Inlet Pressure (Contact Alpha Engineering for additional supply resources) Ign Charger Voltage: Ign Charger Current: 13.5Vdc 6A max. Remote Interface Length: 75ft typical. Distance depends upon installation, derating and wire gauge. Agency Compliance: UL1778, UL2200, NFPA 37/54/58 and 70, CSA C22.2 No.107.1, EMC/FCC Part 15 Class A Fuel System, Controls & Monitoring: Sensors: Safety Shutdowns: Optional Feature: CE-3x2 3.5 or 5kW Generators Model: CE-9x2 3.5 or 5kW The controls and fuel system meet applicable sections of NFPA 37, 54 and 58 for automatic unattended operation of remotely located generators. Full System Control and Status Monitoring included. Gas Hazard, Pad Shear, Water Intrusion & Tamper • Low Oil Pressure • Over Temp • Low Fuel Pressure Shutdown (Propane only) • Water Intrusion • Pad Shear • Gas Hazard (Propane or Natural Gas) • OverSpeed • Over-Crank Cold Start Kit: Provides additional starting capability at temperatures below -18°C / 0°F. CE-3/9G Propane Storage for Generator (For 3.5 and 5kW) PN-6x 7.5kW (PN-6x is not compatible with CE-3/9G) Optional Accessories DCX-PG-WK: Portable Generator Wheel Kit (P/N 745-793-20) DCX-PG-HANDLE: Locking Handle (P/N 745-792-20) AG-PG-TOOL: Punch Tool Kit For Enclosures (P/N 745-131-20) AG-PG-UK: Enclosure Upgrade Kit (P/n 745-131-21) Cable Bag With Cable And Key Lanyard (P/N 745-76421-001) AG-CAB-KIT: Alpha AC Catalogue 2008 For Prin19 19 7/30/2008 3:03:09 PM Alpha AC Catalogue 2008 For Prin20 20 7/30/2008 3:03:09 PM Enclosures Alpha’s hardened outdoor enclosures protect power modules, batteries, and components from harsh environmental conditions and unauthorized access. Our enclosures come in a variety of configurations including side mount, ground mount, or pole mount designs. Alpha can also custom design and manufacture enclosures with specific features for unique applications. Alpha AC Catalogue 2008 For Prin21 21 7/30/2008 3:03:09 PM Enclosures Alpha Outdoor Enclosure Side Mount 6 Stand Alone or Side Mount enclosure Can be installed on any existing ground/pad mount enclosure Engineered to minimize temperature differential between batteries Powder coat finish provides excellent corrosion protection Available in clear coat, sea foam green, pine green and gray Alpha’s Flextra Special Purpose side mount outdoor rated enclosures provide secure and cost effective method of adding standby capacity to any installed ground/pad mount enclosure. For optimum battery life, Flextra Side Mount enclosures have been engineered to minimize the temperature differential between batteries located within the existing enclosure and batteries in the side mount enclosure. The Flextra B4 can be mounted on either the right or the left side of the existing enclosure and has room for 4 x 210Ah AlphaCell™ Batteries. The Flextra B4 kit includes the enclosure and door, key set, and all necessary mounting hardware and installation instructions. Alpha Outdoor Enclosure Side Mount 6 Dimensions (in/mm): 19.5W x 48H x 8.75D/495W x 219H x 222W Enclosures 22 Alpha AC Catalogue 2008 For Prin22 22 7/30/2008 3:03:17 PM Enclosures Alpha B4 Side Mount enclosure Can be installed on any existing ground/pad mount enclosure Engineered to minimize temperature differential between batteries Powder coat finish provides excellent corrosion protection Available in clear coat, sea foam green, pine green and gray Alpha’s B4 side mount outdoor rated enclosure provide secure and cost effective method of adding standby capacity to any installed ground/pad mount enclosure. For optimum battery life, the Side Mount enclosure has been engineered to minimize the temperature differential between batteries located within the existing enclosure and batteries in the side mount enclosure. The B4 can be mounted on either the right or the left side of the existing enclosure and has room for 4 x 210Ah AlphaCell™ Batteries. The B4 kit includes the enclosure and door, key set, and all necessary mounting hardware and installation instructions. B4 Dimensions (in/mm): 19.5W x 48H x 8.75D/495W x 219H x 222W 23 Enclosures Alpha AC Catalogue 2008 For Prin23 23 7/30/2008 3:03:18 PM Enclosures Flextra P Series Universal Mount enclosure Aluminum welded construction Pole mounting brackets included Removable, lockable doors and easy open lids Durable, powder coat finish Slide trays for batteries The P Series is a single power supply enclosure supporting distributed power architectures and used for pole or wall mount installations. The power supply is positioned in a compartment separate from and above the batteries to maximize convection cooling. Ideal for use in all climates, each enclosure includes a high magnetic circuit breaker, studs to mount optional Maintenance Bypass Switch and a cooling fan. Flextra Universal Mount Enclosures Dimensions (in/mm): 24 Weight (lb/kg) Battery Capacity P4 Extended Standby P4 P6 P8 30.25W x 24.75H x 16.0D 768W x 629H x 406D 24.25W x 36.75H x 14.0D 615W x 933H x 355D 30.25W x 36.88H x 16.0D 768W x 937H x 406D 57/26 68/31 121/55 4 6 8 1 2 2 Pole Mount Bracket Enclosures Powder Coat Finish All Aluminum Const. Removable Door/Lid Door Prop Rod Battery Slide Tray 120V 20A or 240V 15A Breaker Duplex/Quad AC Local Remote Indicator Light Enclosure Cooling Fan Storm Hood Battery Heater Mat Internal Service Entrance Breaker Box Factory Installed Breaker Box LA-P+ Standard Features Available Options Note: Color options available. *P6 is only pole or wall mountable P6 Alpha AC Catalogue 2008 For Prin24 24 P8 7/30/2008 3:03:20 PM Enclosures Flextra U Series Ground/Pad Mount enclosure Aluminum welded construction Removable, lockable doors and easy open lids Durable, powder coat finish Slide trays for batteries The U Series is a single power supply enclosure supporting distributed power architectures and used for ground or pad mount installations. The power supply is positioned in a compartment separate from and above the batteries to maximize convection cooling. Ideal for use in all climates, each enclosure includes a high magnetic circuit breaker, studs to mount optional Maintenance Bypass Switch and a cooling fan. U4 Flextra Ground/Pad Mount Enclosures Dimensions (in/mm): Weight (lb/kg) Battery Capacity U4 U6 U8 30.25W x 24.75H x 16.0D 768W x 629H x 406D 24.25W x 36.75H x 14.0D 615W x 933H x 355D 30.25W x 36.88H x 16.0D 768W x 937H x 406D 57/26 68/31 121/55 4 6 8 1 2 2 25 Powder Coat Finish Removable Door/Lid Battery Slide Tray 120V 20A or 240V 15A Breaker Enclosures All Aluminum Const. Duplex/Quad AC Recept. Local Remote Indicator Light Enclosure Cooling Fan Battery Heater Mat LA-P+ AC Output Indicator Light Pedestal Extension External Meter Base Internal Breaker Box External Breaker Box Security Bar Kit Standard Features Available Options U6 Alpha AC Catalogue 2008 For Prin25 25 U8 7/30/2008 3:03:24 PM Enclosures Flextra Z Series Extreme conditions enclosure Meets Telcordia Seismic Zone-4 standard NEMA 3R outdoor rated enclosure Simple, flexible options for pole, wall, ground or pedestal installations Wide temperature range -40˚C to +50˚C Alpha’s Flextra Extreme enclosures provide protection to outdoor UPS systems used in extreme climates. Four and eight battery configurations are available and an optional generator can be used for extended runtimes. Flexible power, runtime and voltage configurations make the Flextra Extreme the best choice for powering outdoor applications around the world. An optional maintenance bypass feature allows for easy and efficient battery and UPS replacement. Flextra Z Standard Features Enclosures 26 Input/Output Surge Protection Intelligent buck/boost operation for greater protection Hot swappable UPS and batteries Noise suppression, FCC Class B Multiple mounting configurations Rugged, outdoor weather resistant construction Lockable enclosure NRTL/CSA/CE approved 8 Battery System also includes: Telcordia Zone 4 approved with Battery Retention Bar Telcordia salt fog tested, 14 day operational Telcordia approved Door Restraint Enclosure Specifications Dimensions 4 Battery Width (in/mm): Height (in/mm): Depth (in/mm): Weight (lb/kg)**: Finish: 24/610 31/788 36/914 37/956 14/56 16/407 350/158 812/368 Powder coat white over aluminum 8 Battery * Backup time depends on load, battery, and operating temperature. Optional DC Generator provides up to 100hrs backup. ** Weight dependent upon internal battery choice. Note: The W8 enclosure is resistant to the harshest weather conditions. Alpha AC Catalogue 2008 For Prin26 26 7/30/2008 3:03:26 PM Enclosures Flextra Node Ground/Pad Mount node Rugged outdoor enclosure available in 3.0 and 5.0kVA configurations Incorporates Alpha CFR power module, Alpha bypass switch and batteries Provides complete input to output isolation with superior surge and lightning protection Additional battery and generators cabinets available Alpha’s Flextra Node Ground/Pad Mount Enclosures provide superior backup power protection for outdoor mission critical applications. Designed to meet or exceed the safety standards established by UL, CSA, CE and VDE, the enclosures set the standard for effective outdoor powering. The input power factor correction brings low power-factor loads to near unity, reducing electric utility costs. Fully compatible with AlphaGenTM Curbside, Alpha’s outdoor line of natural gas or propane generators, to provide longer runtimes. N3 27 Enclosure Configurations Enclosures N3 Dual N3 1 power module 1 bypass switch 1 battery string 1 power module 1 bypass switch 4 battery strings Options: Battery Heater Mat (BHM) Manual Transfer Switch (MTS) Meter Head Standby Generator Propane Storage Cabinet Remote Generator Interface Kit Alpha AC Catalogue 2008 For Prin27 27 7/30/2008 3:03:29 PM Enclosures Radium MiniBay Integrated Telecom grade environmentally controlled UPS system Front and rear accessible 19’” or 23” equipment racks 46 RMU capacity High capacity AC or DC air conditioner options Field replaceable fans NEMA 3R and 4X configurations available Agency certified Radium MiniBay As advanced voice, video and data fiber based services are deployed deeper into the broadband network, the need for reliable, attractive, modular transition nodes increases. The Radium MiniBay supports a wide range of applications including bulk power to CATV hub and secondary hub requirements. Also ideal for remote optical transition applications including optical amplification, downstream DWDM demultiplexing, narrowcast combining and return path aggregation providing services to remote communities. The MiniBay reduces operational costs by locating the electronics where needed and avoids the recurring costs of maintaining a real-estate intensive building. Alpha’s field power services group provides turnkey installations, turn-up and test services. Specifications 28 Environmental Rating: Enclosures Seismic Rating: Design Standards: Compliance: Material: Finish: NEMA 3R when configured with door mounted fans and filter system. NEMA 4X when configured with heat exchanger or air conditioning system. Consult factory. A seismic rating is based on a set system configuration with defined mounting locations and equipment types. Following NEC & Telcordia Technologies (Bellcore) GR-487, GR-63 and GR-108 guidelines. Third party approval from National Recognized Testing laboratory (NRTL). High strength corrosion resistant aluminum Almond color powdercoat finish Equipment Enclosure: Battery Storage Module: 195/88.5 130/59 Dimensions (in/cm): 32D x 44H x 30W / 81.3D x 106.7H x 76.2W 32D x 14H x 30W / 81.3D x 35.6H x 76.2W 32D x 14H x 30W / 81.3D x 35.6H x 76.2W Riser Module: 102/46.3 Side Chamber SC1: 100/45.4 12D x 72H x 32W / 30.5D x 81.3H x 131.1W Side Chamber SC2: 89/40.4 12D x 72H x 32W / 30.5D x 81.3H x 131.1W Fans and Filters The most basic thermal management system supporting the MiniBay utilizes conformal-coated, variable speed and alarm monitored fans with electrostatic air filters providing up to 500W thermal dissipation. This configuration has a NEMA 3R rating. Variable speed controlled DC fans continue to operate during a utility outage Conformal-coated fans Electrostatic and washable air filters Field replaceable fans Alpha AC Catalogue 2008 For Prin28 28 Heat exchanger heat pipe technology provides efficient thermal transfer Minimizes internal temperature rise above external ambient Variable speed controlled DC fans continue to operate during a utility outage Field replaceable fans DC Air Conditioner Weight & Dimensions Weight (lb/kg) Heat Exchanger An airtight rear door and a heat exchanger equipped hinged front door providing over 500W thermal dissipation. With a 500W load, the internal ambient temperature will not exceed 15 to 27°F above external ambient. With a 250W load, the internal ambient temperature will not exceed 7°C or 12.6°F above external ambient. This configuration has a NEMA 4X rating. For applications requiring the most reliable below ambient cooling and dehumidifying system for supporting seamless performance through extended utility outages. Cooling capacity 878W dissipated at 43°C outdoor ambient allowing a Maximum* internal ambient of 40°C / 104°F. Variable speed brushless motor 24/48Vdc compressor system assures optimum efficiency over the full range of thermal loading and ambient temperatures 3,000BTU @ 43°C/110°F rating Redundant conformal-coated fans have >50,000hrs of life and low voltage disconnect circuitry AC Air Conditioner Ideal for applications requiring cooling and dehumidifying with little or no standby runtime performance. Cooling capacity 1464W dissipated at 43°C outdoor ambient allowing a Maximum* internal ambient of 40°C / 104°F. 5,000BTU @ 43°C/110°F rating Washable electrostatic filters 240Vac * Reducing the internal dissipated heat load reduces internal ambient. MiniBay with Fiber Management 7/30/2008 3:03:31 PM Indoor Solutions Alpha Technologies offers three lines of single phase indoor Uninterruptible Power Supplies (UPS), providing customers with a range of standard and optional features to meet their specific UPS needs. This includes entry level line interactive models, full featured double conversion products and controlled ferroresonant designs for the most robust applications. All lines are offered in tower and rack mount configurations. An additional indoor UPS family, part of our controlled ferroresonant line is designed specifically for medical and healthcare applications. We also offer three phase indoor UPS solutions. Alpha AC Catalogue 2008 For Prin29 29 7/30/2008 3:03:31 PM Indoor Solutions UPS Topology Diagrams below will help you understand the different topologies used in our indoor UPS products. Line Interactive 30 In normal operation, when AC line voltage is present, power is filtered for voltage spikes and output voltage is regulated. Some electricity is used to keep the batteries fully charged. When the AC line voltage is lost or falls outside the input range, AC power is supplied from the batteries through the inverter. Indoor Solutions Advantages of line-interactive topology: • Automatic Voltage Regulation (AVR) • Lower electricity consumption (less costly to operate) – More efficient because less power conversion is performed when acceptable AC input is present. • Higher reliability – Lower component count and lower operating temperatures. Double conversion In normal operation, all incoming AC power is rectified to DC power, supplying the DC bus. The output inverter then inverts the DC power to AC power to support the critical loads. When the AC input is lost or goes out of range, the UPS draws power from its battery so that AC output is not affected. Because the AC input with it’s spikes, voltage blips and anomalies is first converted to DC, there is less need for using the battery when these AC input variances occur. Less battery usage preserves battery capacity for extended outages, and preserves battery service life. Alpha AC Catalogue 2008 For Prin30 30 7/30/2008 3:03:31 PM Indoor Solutions UPS Topology Double conversion continued Reducing battery service life and the cost associated with it can offset the advantage of the lower initial purchase and operating costs of a line-interactive UPS thus making the overall cost similar. Situations that might call for a double-conversion on-line UPS are those that require power factor correction (PFC), small physical size, or some types of medical equipment or instrumentation. Advantages of double-conversion topology: • Operates less often from battery when the input voltage is highly distorted or wildly fluctuating • Power factor correction (PFC) provided, regardless of load type • More compact and lightweight, especially at higher power levels 31 Indoor Solutions Controlled Ferroresonant The Ferro Resonant Topology is similar to a Line Interactive topology with the addition of a ferro resonant transformer to offer constant output voltage regardless of the state of the input voltage. In both normal mode and battery mode, all output is first filtered through a ferro resonant transformer isolating the output. This also provides for a seamless transfer to UPS power and offers galvanic isolation to isolate charge carrying particles from functional section of the system. Auto Voltage Regulation (AVR) is managed through Buck & Boost Mode. Advantages of controlled ferro resonant topology: • Best spike & surge protection with output isolation • Zero transfer time • Good MTBF as inverter is used in Standby mode • Batteries are not used in a brown out condition Alpha AC Catalogue 2008 For Prin31 31 7/30/2008 3:03:31 PM Line Interactive ALI Elite 1000 VA to 3000 VA models Line interactive, pure sine wave technology High speed microprocessor controlled Advanced Automatic Voltage Regulation Smart battery management Hot swappable batteries XL models for longer run times The ALI Elite Uninterruptible Power Supply (UPS), in tower or rack mount configurations, is a microprocessor-controlled, pure sine wave, line interactive UPS featuring advanced Auto Voltage Regulation (AVR) with boost and buck. The AVR provides a wider input voltage operating range that results in fewer transfers to battery power thus extending battery life. All Alpha ALI Elite models include graphical interface, user-friendly software ALI Elite rack configuration capable of safe unattended PC shutdown. Additional features include: smart battery management programming to optimally charge a battery based on it’s specific charging sequence, automatic frequency selection, smart communication, a robust inverter that works with a variety of external battery packs for extended run time applications, a customizable graphical user interface displaying UPS status, TCP/IP based power management and an optional Ethernet/SNMP interface. The ALI Elite is designrd to work in applications supporting servers, telecom equipment, voice and data networks or where there is a need for indoor, line interactive backup power. Indoor Solutions 32 ALI Elite tower configuration Alpha AC Catalogue 2008 For Prin32 32 7/30/2008 3:03:34 PM Line Interactive ALI Elite Nominal Specifications Model Tower Part Number: Rack Mount: Part Number: ALI Elite 1000T ALI Elite 1500T ALI Elite 2000T ALI Elite 3000T 017-747-110 017-747-115 017-747-120 017-747-130 ALI Elite 1000RM ALI Elite 1500RM ALI Elite 2000RM ALI Elite 3000RM 017-747-61 017-747-65 017-747-62 017-747-63 Capacity (VA/W): 1000VA/600W 1500VA/900W 2000VA/1200W 3000VA/1800W Input Plug: NEMA 5-15P NEMA 5-15P NEMA L5-20P NEMA L5-30P Input Protection Fuse Fuse Breaker 20A Breaker 30A Audible Noise: <40dBA @ 1m <40dBA @ 1m <40dBA @ 1m <40dBA @ 1m Tower: 4 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-20R 4 NEMA 5-15R, 1 NEMA 5-30R Rack Mount: 4 NEMA 5-15R 4 NEMA 5-15R 4 NEMA 5-20R 4 NEMA 5-15R, 1 NEMA 5-30R 24V 36V 48V 48V Receptacles Battery DC Voltage: Battery Runtimes* Tower and Rack Runtime @ 100% Load: 3min 3min 3min 7min Runtime @ 50% Load: 13min 13min 13min 21min (in): 5.5W x 17.2D x 8.3H 6.7W x 17.7D x 8.9H 6.7W x 17.7D x 8.9H 6.7W x 22.8D x 16.9H (mm) 140W x 436D x 210H 170W x 450D x 226H 170W x 450D x 226H 170W x 580D x 430H Weight (lb/kg): 33.0/15 55.1/25 66.1/30 80/36 Approx. Ship Weight (lb/kg): 35.0/16 59.5/27 70.5/32 83.7/38 (in): 16.9W x 15.0D x 5.1H 16.9W x 15.0D x 5.1H 16.9W x 15.0D x 5.1 16.9W x 22.1D x 7.0H (mm): 429.3W x 381D x 130H 429.3W x 381D x 130H 429.3W x 381D x 130 429.3W x 560D x 178H Weight (lb/kg): 44/20 57.3/26 61.7/28 75/34 Approx. Ship Weight (lb/kg): 48/22 63.4/28.8 68.5/31.1 79.3/36 33 Mechanical Tower Indoor Solutions Rack Mount *rounded to the nearest minute General Specifications AC Input Voltage: 120V nominal Voltage Range: ±25% Frequency: 50/60Hz ±5% (auto sensing) AC Output Battery Recharge Time: Type: Interface <5hrs to 90% recharge of internal batteries only Valve Regulated Lead Acid (VRLA) No extended battery packs (available on XL models only) Front Panel Indicators: Audible Alarm: Communications: LED display–load level and battery capacity On battery–Slow beep, low battery–rapid beep, overload–continuous RS-232 with optional external SNMP Voltage (Selectable): 100/110/120V Frequency: 50 or 60Hz ±0.5% when on battery Regulation: Increase of 15% if input voltage is -9 to -25% from nominal Decrease of 15% if input is 9 to 25% from nominal Spike Protection: 320Joules, 2ms EMI/RFI Filtering: 10dB at 0.15MHz, 50dB at 30Mhz Operating Temperature: Storage Temperature: Altitude: Humidity: Safety: Overload Capacity: 110% for 20sec, 125% for 5sec Warranty Transfer Time: 2 to 4ms, including detection time Waveform: Sine wave UPS Module and Battery:Competitive warranties included. Contact your sales representative for further details. Alpha AC Catalogue 2008 For Prin33 33 Environment 0 to 40°C -20 to 48°C 3500m above sea level 0 to 95% non-condensing UL, CSA 7/30/2008 3:03:34 PM Line Interactive ALI Elite XL All the same features and benefits of the ALI Elite with the capability of longer run times. Nominal Specifications Model Tower: ALI Elite 1000TXL ALI Elite 1500TXL ALI Elite 2000TXL ALI Elite 3000TXL Part Number: 017-747-210 017-747-215 017-747-220 017-747-230 Rack Mount: ALI Elite 1000RMXL ALI Elite 1500RMXL ALI Elite 2000RMXL ALI Elite 3000RMXL Part Number: 017-747-81 017-747-85 017-747-82 017-747-83 Capacity VA/W: 1000VA/600W 1500VA/900W 2000VA/1200W 3000VA/1800W Input Plug: NEMA 5-15P NEMA 5-15P NEMA L5-20P NEMA L5-30P Input Protection: Fuse Fuse Breaker Breaker Audible Noise: <40dBA @ 1m <45dBA @ 1m <45dBA @ 1m <45dBA @ 1m Tower: 6 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-20R 4 NEMA 5-15R, 1 NEMA 5-30R Rack Mount: 6 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-20R 4 NEMA 5-15R, 1 NEMA 5-30R 24V 36V 48V 48V (in): 6.7W x 17.7D x 8.9H 6.7W x 18.9D x 16.9H 6.7W x 18.9 x 16.9H 6.7W x 21.6D x 16.9H (mm): 170.2W x 449.6D x 226.1H 170.2W x 480.1D x 429.3H 170.2W x 480.1D x 429.3H 170.2W x 548.6D x 429.3H Weight (lb/kg): 66/30 94.8/46 110.2/50 125.7/57 Approx. Ship Weight (lb/kg): 70.5/32 108/49 116/53 132/60 (in): 16.9W x 22.0D x 5.1H 16.9W x 22.0D x 5.1H 16.9W x 22.0D x 5.1H 16.9W x 22.0D x 7.0H (mm): 429.3W x 558.2D x 129.5H 429.3W x 558.2D x 129.5H 429.3W x 558.2D x 129.5H 429.3W x 558.2D x 177.8H Weight (lb/kg): 41.9/19 52.9/24 59.5/27 103.6/47 Approx. Ship Weight (lb/kg): 46.2/21 57.3/26 63.7/29 108/49 Receptacles Battery DC Voltage: 34 Mechanical Indoor Solutions Tower Rack Mount General Specifications 120V nominal ±25% 50/60 Hz ±5% (auto sensing) Interface Front Panel Indicators: LED display – load level and battery capacity. Audible Alarm: On battery – Slow beep, low battery – rapid beep, overload – continuous Communications: RS-232 with optional ethernet/SNMP. 100/110/120V 50 or 60Hz ±0.5% when on battery ±10% nominal 320 Joules, 2ms 10dB at 0.15MHz, 50dB at 30mHz 125% for 10min, 150% for 10sec 2 to 4ms, including detection time Sine wave Environment Operating Temperature: Storage Temperature: Altitude: Humidity: Safety: AC Input Voltage: Voltage Range: Frequency: AC Output Voltage (Selectable): Frequency: Regulation: Spike Protection: EMI/RFI Filtering: Overload Capacity: Transfer Time: Waveform: Battery Recharge Time: Type: Alpha AC Catalogue 2008 For Prin34 34 <5hrs to 90% recharge of internal batteries only Valve Regulated Lead Acid (VRLA) Extended battery connectors included Extended battery packs available Warranty UPS Module and Battery: 0 to 40°C -20 to 48°C 3500m above sea level 0 to 95% non-condensing UL, CSA Competitive warranties included. Contact your sales representative for further details. 7/30/2008 3:03:35 PM Line Interactive Ali Elite XL ALI Elite Extended Run Time Battery Pack The ALI Elite also has optional battery packs to further extend your run time during a power failure. Review the table below to find a solution to best fit your needs. ALI Elite XL Specifications Battery Pack: ALIBP700/1000T ALIBP1500T ALIBP2/3000T Alpha Part Number: 033-747-07 033-747-10 033-747-20 Dimensions (in): 6.7W x 18.9D x 8.5H 6.7W x 18.9D x 8.5H 6.7W x 18.9D x 8.5H 170.2W x 480.1D x 215.9H 170.2W x 480.1D x 215.9H 170.2W x 480.1D x 215.9H Weight (lb/kg): (mm): 69.4/31.5 56.2/25.5 69.4/31.5 Approx. Ship Weight (lb/kg): 73.9/33.5 60.6/27.5 73.9/33.5 Battery Pack: ALIBP700/1000RM ALIBP1500RM ALIBP2/3000RM Alpha Part Number: 033-747-08 033-747-12 033-747-22 Dimensions (in): 16.9W x 15.7D x 5.1H 16.9W x 15.7D x 5.1H 16.9W x 15.7D x 5.1H Specifications (mm): 429.3W x 398.8D x 129.5H 429.3W x 398.8D x 129.5H 64.5/29.65 64.5/29.65 64.5/29.65 Approx. Ship Weight (lb/kg): 72.6/32.95 72.6/32.95 72.6/32.95 Battery Runtimes* ALI Elite 1000 TXL/RMXL ALI Elite 1500 TXL/RMXL ALI Elite 2000 TXL/RMXL ALI Elite 2000 TXL/RMXL UPS: 36 min 53 min 53 min 29 min 1 EBP: 202 min 123 min 123 min 78 min 2 EBP: 369 min 202 min 202 min 123 min UPS: 12 min 19 min 19 min 9 min 1 EBP: 92 min 53 min 53 min 29 min 2 EBP: 163 min 92 min 92 min 53 min UPS: 36 min 16 min 16 min 15 min 1 EBP: 212 min 126 min 102 min 66 min 2 EBP: 416 min 248 min 189 min 120 min UPS: 13 min 6 min 6 min 5 min 1 EBP: 97 min 54 min 40 min 26 min 2 EBP: 179 min 111 min 86 min 52 min Indoor Solutions 429.3W x 398.8D x 129.5H Weight (lb/kg): 35 Tower at 50% Load Tower at 100% Load Rack at 50% Load Rack at 100% Load *rounded to the nearest minute Alpha AC Catalogue 2008 For Prin35 35 7/30/2008 3:03:36 PM Double Conversion Pinnacle Plus 1000VA to 3000VA models to meet your power needs True online, double conversion operation (zero transfer time) Internal Static Bypass: no extra parts to buy for complete operation Power factor correction: minimize energy consumption Optional Ethernet SNMP communications interface: monitor from anywhere Pinnacle Plus tower configuration Hot swappable batteries: no downtime Indoor Solutions 36 The Pinnacle Plus Uninterruptible Power Supply (UPS), in tower or rack mount configurations provides safe, clean, Pinnacle Plus reliable power protection to data and voice networking equipment, rack configuration telecommunication systems, servers and other mission-critical applications. The Pinnacle Plus offers an advanced fully microprocessor controlled technology that quickly reacts to varying output conditions and continually offers pure sine wave power to critical equipment with zero transfer time. The advanced, scalable battery charger shortens the battery recharge time while prolonging the life of the battery. With true RS-232 & USB two-way communication that sends signals to both the network and computer, the Pinnacle Plus can be monitored, shut down, or programmed with an on/off date, using its own software. Simplified control circuits make it light, easy to control, and reliable due to the reduction of internal components. General Specifications AC Input Interface Voltage Range: 80 to 144V at full load, 60 to 144V at 40% load (120V Units) Frequency: 50/60Hz ±5% (auto sensing) AC Output Voltage (selectable): 100/110/115/120/127V (PIN 1000 to 3K) Frequency: 50 or 60Hz ±0.5% when on battery Receptacle Segments: 2 – software controllable Front Panel Indicators: LCD display/input/output volts, frequency, load level, battery capacity, online/eco mode Audible Alarm: On Battery – 5 second interval, UPS fault – continuous Communications: RS-232, communications expansion slot, USB standard (Options: AS400 Card, UPS LAN Card) Voltage THD, Linear Load: <3% Environment Crest Factor: 3:1 Operating Temperature: 0 to 40°C Overload Capacity: 125% for 1min, 150% for 10sec Storage Temperature: -20 to 50°C Transfer Time: 0ms Altitude: 3500m above sea level Extended Battery Humidity: 0 to 95%, non-condensing Recharge Time: <4hrs to 90% recharge on internal battery Audible Noise: <40dBA at 1m Type: Valve Regulated Lead Acid (VRLA) Safety: UL, CSA Extended battery connection included. EMC (EMS/EMI): IEC 61000-4. FCC Part 15, CISPR22 Extended battery packs available High Efficiency Mode: >95% efficient when selected Alpha AC Catalogue 2008 For Prin36 36 7/30/2008 3:03:37 PM Double Conversion Pinnacle Plus Nominal Specifications PINNACLE Plus 1000T 017-751-10 PINNACLE Plus 1000RM 017-751-122 1000VA/700W NEMA 5-15P Circuit Breaker 12A PINNACLE Plus 1500T 017-751-15 PINNACLE Plus 1500RM 017-751-17 1500VA/1050W NEMA 5-15P Circuit Breaker 15A PINNACLE Plus 2000T 017-751-20 PINNACLE Plus 2000RM 017-751-22 2000VA/1400W NEMA L5-20P Circuit Breaker 20A PINNACLE Plus 3000T 017-751-30 PINNACLE Plus 3000RM 071-751-32 3000VA/2100W NEMA L5-30P Circuit Breaker 30A 6 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-15R 10 NEMA 5-20R, 1NEMA L5-20R 2 NEMA 5-20R, 1 NEMA L5-20R 10 NEMA 5-15R, 1 NEMA L5-30R 2 NEMA 5-15R, 1 NEMA L5-30R 36V 36V 72V 72V 6W x 16.5D x 9.4H 6W x 16.5D x 9.4H 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H 152.4W x 419.1D x 238.8H 152.4W x 419.1D x 238.8H 226.1W x 424.2D x 360.7H 226.1W x 424.2D x 360.7H 35.3/17.1 40/18.9 37.5/17.7 41.8/19.5 68.3/33.8 73.9/36 72.8/35.6 78.1/38 16.9W x 16.7D x 3.3H 16.9W x 16.7D x 3.3H 16.9W x 25D x 3.3H 16.9W x 25D x 3.3H 429.3W x 424.2D x 83.8H 429.3W x 424.2D x 83.8H 429.3W x 609.6D x 83.8H 429.3W x 609.6D x 83.8H 37.5/18.7 42.5/21.6 39.7/19.1 44.2/21.7 70.6/33.6 74.4/36.7 72.8/34.3 78.5/38.3 18min 148min 310min 14min 92min 205min 18min 80min 150min 14min 50min 93min 6min 69min 150min 5min 38min 80min 6min 33min 69min 5min 19min 40min 18min 148min 310min 14min 92min 205min 18min 80min 150min 14min 50min 93min 6min 69min 150min 5min 38min 80min 6min 33min 69min 5min 19min 40min 37 Indoor Solutions Model Tower: Part Number: Rack Mount 2U: Part Number: Capacity (VA/W): Input Plug: Input Protection: Receptacles Tower: Rack Mount: Battery DC Voltage: Mechanical Tower Dimensions (in): (mm): Net Weight (lb/kg): Approx. Ship Weight. (lb/kg): Rack Mount Dimensions (in): (mm): Net Weight (lb/kg): Approx. Ship Weight (lb/kg): Battery Runtimes* Tower at 50% Load UPS: 1 EBP: 2 EBP: Tower at 100% Load UPS: 1 EBP: 2 EBP: Rack at 50% Load UPS: 1 EBP: 2 EBP: Rack at 100% Load UPS: 1 EBP: 2 EBP: *rounded to the nearest minute Alpha AC Catalogue 2008 For Prin37 37 7/30/2008 3:03:38 PM Double Conversion Pinnacle Plus High Power 6000, 10,000 and 12,000W/VA models to meet every power need True online, double conversion operation (zero transfer time) Internal Static Bypass: no extra parts to buy for complete operation Power factor correction: minimize energy consumption Optional Ethernet SNMP communications interface: monitor from anywhere Hot swappable batteries: no downtime Pinnacle Plus High Power tower configuration (available Q4, 2008) The Pinnacle Plus Uninterruptible Power Supply (UPS), in tower or rack mount configurations provides safe, clean, reliable power protection to data and voice networking equipment, telecommunication systems, servers and other mission-critical applications. The Pinnacle Plus offers an advanced fully microprocessor controlled technology that quickly reacts to varying output conditions and continually offers pure sine wave power to critical equipment with zero transfer time. The advanced, scalable battery charger shortens the battery recharge time while prolonging the life of the battery. With true RS-232 two-way communication that sends signals to both the network and computer, the Pinnacle Plus can be monitored, shut down, or programmed with an on/off date, using its own software. Simplified control circuits make it light, easy to control, and reliable due to the reduction of internal components. 38 General Specifications Indoor Solutions AC Input Interface Voltage Range: 180 to 276 VAC Frequency: 50/60Hz ±5% (auto sensing) AC Output Voltage (selectable): 200/208/220/230/240 Frequency: 50 or 60Hz ±0.5% when on battery Receptacle Segments: 2 – software controllable Front Panel Indicators: LCD display/input/output volts, frequency, load level, battery capacity, online/eco mode Audible Alarm: On Battery – 5 second interval, UPS fault – continuous Communications: RS-232, communications expansion slot, USB standard (Options: AS400 Card, Voltage THD, Linear Load: <3% UPS LAN Card) Crest Factor: 3:1 Environment Overload Capacity: 125% for 1min, 150% for 10sec Operating Temperature: 0 to 40°C Transfer Time: 0ms Storage Temperature: -20 to 50°C Altitude: 3500m above sea level Extended Battery Recharge Time: <4hrs to 90% recharge on internal battery Humidity: 0 to 95%, non-condensing Type: Valve Regulated Lead Acid (VRLA) Audible Noise: <40dBA at 1m Extended battery connection included. Safety: UL, CSA Extended battery packs available EMC (EMS/EMI): IEC 61000-4. FCC Part 15, CISPR22 High Efficiency Mode: >95% efficient when selected Alpha AC Catalogue 2008 For Prin38 38 7/30/2008 3:03:38 PM Double Conversion Pinnacle Plus High Power Model Tower Part Number: Capacity (VA/W): Input Plug: Input Protection: Receptacles Tower: Battery DC Voltage: Mechanical Tower Dimensions (in): (mm): Net Weight (lb/kg): Approx. Ship Weight (lb/kg): Battery Runtimes Tower at 50% Load UPS: Tower at 100% Load UPS: PINNACLE Plus 6000T 017-751-400 6000VA/4200W Terminal Block Circuit Breaker PINNACLE Plus 10000T 017-751-300 10000VA/7000W Terminal Block Circuit Breaker PINNACLE Plus 12000T 017-751-580 12000VA/8400W Terminal Block Circuit Breaker Terminal Block Terminal Block Terminal Block 240V 240V 240V 10.1W x 23.2D x 22.4H 257.8W x 699.8D x 699.4H 209 / 95 Contact Alpha 10.1W x 27.2D x 28.2H 324.4W x 739.2D x 729.4 H 332 / 151 Contact Alpha 13.5W x 27.2D x 34.6H 342W x 690D x 903H 435 / 198 Contact Alpha 19min 37min 53min 6min 13min 19min Extended Run Time Battery Pack Specifications for Pinnacle Plus Tower PINBP1000/1500T PINBP2/3000T PINBP2/3000T PINBP6000T PINBP10000/12000T Alpha P.N.: 033-751-10 033-751-10 033-751-20 033-751-20 033-751-400 017-751-311 Dimensions (in): 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H 10.2W x 27.4D x 22.4H 13.5W x 24.1D x 25.9H/ 13.5W x 24.5D x 25.96H (mm): 226W x 424D x 360H 226W x 424D x 360H 226W x 424D x 360H 226W x 424D x 360H 258W x 697D x 570H 344W x 613D x 657H/ 344W x 623D x 657H Weight (lb/kg): 92.6/42 92.6/42 92.6/42 92.6/42 Contact Alpha Contact Alpha Approx. Ship Weight (lb/kg): 98.1/44.5 98.1/44.5 98.1/44.5 98.1/44.5 Contact Alpha Contact Alpha 39 Indoor Solutions Battery Pack: PINBP1000/1500T Extended Run Time Battery Pack Specifications for Pinnacle Plus Rack Mount Battery Pack: PINBP1000/1500RM PINBP1000/1500RM PINBP2/3000RM PINBP2/3000RM Alpha Part Number: 033-751-12 033-751-12 033-751-22 033-751-22 Dimensions (in): 16.9 x 25 x 3.3H 16.9 x 25 x 3.3H 16.9 x 25 x 3.3H 16.9 x 25 x 3.3H 429.3W x 635D x 83.8H 429.3W x 635D x 83.8H 429.3W x 635D x 83.8H 429.3W x 635D x 83.8H Weight (lb/kg): 95.9/43.5 95.9/43.5 95.9/43.5 95.9/43.5 Approx. Ship Weight (lb/kg): 101.4/46 101.4/46 101.4/46 101.4/46 (mm): Alpha AC Catalogue 2008 For Prin39 39 7/30/2008 3:03:38 PM Controlled Ferroresonant CFR® One of the highest MTBF in the UPS industry - lowers total cost of ownership Complete input to output isolation provides complete surge and lightning protection for sensitive loads The CFR’s microprocessor design provides efficiency ratings up to 92%, saving energy Features a RS-232 communication port and is SNMP and modem compatible for monitoring from any Internet connection location CFR Series Alpha CFR Uninterruptible Power Supplies (UPS) meet or exceed the safety standards established by UL, CSA, CE and VDE. The Alpha CFR UPS is one of the most reliable UPS systems available, with a wide variety of plug and receptacle options to meet your unique connection requirements. Input current waveform correction eliminates overheating effects of non-linear load current harmonics. Input power-factor correction brings low power-factor loads to near unity, reducing electric utility costs. The CFR Series sets the standard for the effective powering of non-linear or actively regulated loads, while providing superior surge and noise rejection. Power ratings of 1000VA to 15kVA available. Indoor Solutions 40 Alpha AC Catalogue 2008 For Prin40 40 7/30/2008 3:03:39 PM Controlled Ferroresonant CFR® Application Specific Models Common Specifications Input Frequency Operating Range: Operating Input Voltage Range: -23 to 10% ±1.4Hz CFR-NT: Specifically designed to be compatible with Northern Telecom Meridian telephone switches and other telephony products Input Power Factor 0.95 to 0.99 CFR-E: 50Hz configuration Input Current THD: 5% Typical Output Waveform: Pure sine wave ±1% Plug and Receptacle Diagram 5-15P 5-15R 5-30P 5-30R Output Voltage Regulation: Inverter Frequency Stability: Typical Output Voltage THD: <5% 600VA to 5kVA ±0.1% Spike Attenuation: 2000 to 1 Lightning & Surge Protection: ANSI C62.41-1980 (IEEE 587) Operating Temperature: 0 to 40°C (32 to 104°F) Audible Noise: 40dBA Typical @ 1m 5-20P 5-50P L5-15P L5-30P L6-30P 5-20R L5-15R L5-20R L5-30R L6-20R L6-30R CS6361 Terminal Block British Schuko Australian Communications All Alpha CFR products feature RS-232 communication ports and are SNMP and modem compatible. The following is a list of optional communication, monitoring and control products: SNMP Agent: Furnishes real time UPS/power status to Network Power Management Software. 41 Intelligent Interface Device (I2D): Front panel LCD readout provides vital UPS system information at the touch of a key. EBP Options Available for: CFR 1000 Available for: EBP 24A EPB 24C EBP 24E CFR 5000 Width (in/mm): 8.5/216 8.5/216 8.5/216 Height (in/mm): 4.5/114 21.5/546 Depth (in/mm): 15.5/394 10.5/267 24.0/610 Weight (lb/kg): Capacity (Ah): 39/18 17 127/58 66 312/141 176 Battery Pack 48V Width (in/mm): Height (in/mm): Depth (in/mm): Weight (lb/kg): Capacity (Ah): Battery Pack 24V Indoor Solutions Alpha’s plug-in External Battery Packs provide extended backup for all CFR models. All battery packs are shipped fully assembled and include interconnecting cables. Longer runtimes are obtained by cascading additional battery cabinets. 28.0/711 EBP 48M 8.5/216 21.5/564 28.0/711 312/141 88 EBP 1275-48B 22.0/660 30.3/770 31.5/800 905/411 264 Available for: CFR 1500, 2500, 3000 Battery Pack 48V Width (in/mm): Height (in/mm): Depth (in/mm): Weight (lb/kg): Capacity (Ah): Alpha AC Catalogue 2008 For Prin41 41 EBP 48A 8.5/216 10.5/267 10.5/267 127/58 33 EBP 48E 8.5/216 21.5/546 21.5/546 312/141 88 7/30/2008 3:03:41 PM Controlled Ferroresonant CFR® Nominal Specifications Model Number: Output Power Rating: Indoor Solutions 42 60Hz Models (CFR, CFR-NT & CFR-M) Input Voltage (VAC) Nominal: Output Voltage (VAC) Nominal: 50Hz Models (CFR-E) Input/Output Voltage (VAC) Nominal: Typical Efficiency -AC/AC 100% Load: Typical Heat Output - Line Mode: Mechanical Width (in/mm): Height (in/mm): Depth (in/mm): 60Hz Weight (lb/kg): 60Hz Ship Weight (lb/kg): 50Hz Weight (lb/kg): 50Hz Ship Weight (lb/kg): Internal Battery Runtime 100%*: Internal Battery Recharge Time: (To 80% of Capacity) Extended Battery Runtime Options* A. External Battery Pack (EBP): Total Runtime**: B. External Battery Pack (EBP): Total Runtime**: C. External Battery Pack (EBP): Total Runtime**: 60Hz Power Connector Options† Input: CFR, CFR-C, CFR-M, CFR-RM Models: CFR 1000 CFR 1000 E 1000VA 750W CFR 1500 CFR 1500 E CFR 1500 NT 1500VA 1000W CFR 2000 CFR 2000 E CFR 2000 NT 2000VA 1334W CFR 2500 CFR 2500 E CFR 2500 NT 2500VA 1667W CFR 3000 CFR 3000 E CFR 3000 NT 3000VA 2000W CFR 5000 CFR 5000 E CFR 5000 NT 5000VA 3750W 120 120 120/208/240 120/208/240 120/208/240 120/208/240 120/208/240 120/208/240 120/208/240 120/208/240 120/208/240 120/208/240 230 90% 284 BTU/h 230 90% 427 BTU/h 230 90% 398 BTU/h 230 90% 636 BTU/h 230 90% 758 BTU/h 230 90% 1425 BTU/h 8.5/216 10/254 20/508 92/42 97/44 93.42 98/44 12min 8.5/216 21/533 22.5/571 151/69 162/73 163/74 174/79 18min 8.5/216 21/533 22.5/571 171/78 182/83 181/82 192/87 15min 8.5/216 21/533 22.5/571 185/84 200/91 190/86 205/93 10min 8.5/216 21/533 29.5/749 283/128 312/142 313/142 332/151 27min 12/305 22.5 /569 29.4/747 375/170 453/206 381/173 477/216 12min 5hrs typical 5hrs typical 5hrs typical 5hrs typical 5hrs typical 5hrs typical EBP 24A 32min EBP 24C 2hrs 12min EBP 24E 5hrs 12min EBP 48A 1hr 39min EBP 48E 3hrs 45min EBP 48A 1hr 10min EBP 48E 2hrs 48min EBP 48A 52min EBP 48E 2hrs 10min EBP 48A 1hr 15min EBP 48E 2hrs 30min EBP 48M 1hr 15min EBP 1275-48B 3hrs 44min 5-15P L5-15P T. B. 5-20P L5-20P T. B. L6-30R 5-15R 5-20R 6-20R L5-15R L5-20R L5-30R L6-20R 5-30R L6-30R T. B. 5-15R 2-L6-30R L6-30R 5-15R 5-20R 6-20R L5-15R L5-20R L5-30R L6-20R 5-30R L6-30R T. B. 5-15R 2-L6-30R 5-30P L5-30P L6-30P T. B. L6-30R 5-15R 5-20R 6-20R L5-15R L5-20R L5-30R L6-20R 5-30R L6-30R T. B. 5-15R 2-L6-30R 5-30P L5-30P L6-30P Terminal Block L6-30 5-15R 5-20R 6-20R L5-15R L5-20R L5-30R L6-20R 5-30R L6-30R Terminal Block 5-15R 2-L6-30R 5-50P CS6361 L6-30P*** Terminal Block L6-30 5-15R 5-20R 6-20R L5-15R L5-20R L5-30R L6-20R 5-30R L6-30R Terminal Block 5-15R 3-L6-30R British Schuko Australian British Schuko Australian British Schuko Australian British Schuko Australian British Schuko Australian T.B. T.B. T.B. 5-15P CFR-NT Models: Output: CFR, CFR-C, CFR-M, CFR-RM Models: N/A 5-15R CFR-NT Models: N/A 50Hz Power Connector Options† Input /Output: CFR-E Models: L5-15R British Schuko Australian Output Power Connector Configuration Options: 1) Any 2 single or 2 duplex receptacles UPS Warranty: 24 month limited warranty Battery: 24 month limited warranty 1) Any combination of 3 or less duplex receptacles 2) Any combination of 2 or less single receptacles 3) Any duplex receptacle with any single receptacle 4) Single terminal block * Battery runtimes are calculated at 100% rated loads and will vary according to battery age, loads, temperature and other factors. ** Total runtime include the internal batteries and the External Battery Pack (EBP) at 100% load. † Refer to Plug and Receptacle Diagram on last page. Alpha AC Catalogue 2008 For Prin42 42 7/30/2008 3:03:42 PM Controlled Ferroresonant - Health Care AlphaMED® Maximum power protection for complete isolation and uninterruptible power, assuring the ongoing performance of sensitive medical equipment Meets demanding UL 60601-1 medical safety standards, allowing use in most medical and healthcare environments Low current leakage supports patient vicinity equipment Optional external battery packs greatly extend backup time AlphaMED Generator compatibility meets even the longest runtime requirements !LPHA-%$"ACK0ANEL Clean, safe reliable power is critical to the health care industry. The AlphaMED® is the answer. The AlphaMED® ensures clean, reliable power, pure sine wave output power to within one percent of the nominal voltage requirement and meets the most stringent lowest leakage current requirements in the industry. Sophisticated medical equipment such as ultrasound systems, film processors, laboratory systems, and other health care devices need optimal power protection, as well as a low audible noise level. The AlphaMED® external battery packs greatly extend the backup time (up to 8 hours) allowing users to work through power outages and disturbances without interruption, rather than shutting down critical medical equipment. `iÊ*ÀÌ ,-ÓÎÓÊ -iÀ>Ê *ÀÌ "ÕÌ«ÕÌÊÀi>iÀ 43 ëÌ>ÊÀ>`iÊ "ÕÌ«ÕÌÊ ,iVi«Ì>Vià Indoor Solutions Featuring an intelligent user interface, the AlphaMED® provides information and power management capacity on stand-alone or network configuration. RS-232 port, Ethernet/SNMP compatibility and remote call-out paging adds to the UPS’s advanced communications functions. Each unit comes with an automatic self-test capability and can provide an orderly, unattended shutdown of medical systems in the event of an extended power outage. Ìi}iÌÊ ÌiÀv>ViÊ iÛVi ÕV>ÌÃÊ*ÀÌ "ÕÌ«ÕÌÊÀi>iÀ «ÕÌÊ Ài>iÀ AlphaMED back panel £x½ÊëÌ>ÊÀ>`iÊiÊ À` ëÌ>ÊÀ>`iÊ«ÕÌÊ *Õ} Alpha AC Catalogue 2008 For Prin43 43 7/30/2008 3:03:43 PM Controlled Ferroresonant - Health Care AlphaMED® Nominal Specifications Model Number: AlphaMED® 1000 AlphaMED® 1000E AlphaMED® 1500 AlphaMED® 1500E AlphaMED® 2000 AlphaMED® 2000E AlphaMED® 2500 AlphaMED® 2500E AlphaMED® 3000 Output Power Rating: Input/Output Voltage (VAC) Nominal: Typical Efficiency - AC/AC 100% Load: Typical THD: Typical Heat Output - Line Mode: Audible Noise at 1m: Waveform: 1000VA / 750W 120 230 90% 1500VA / 1000W 120/208/240* 230 90% 2000VA / 1334W 120/208/240* 230 90% 2500VA / 1667W 120/208/240* 230 90% AlphaMED® 3000E 3000VA / 2000W 120/208/240* 230 90% 5% 5% 427BTU/h 5% 398BTU/h 5% 636BTU/h 5% 758BTU/h <38dBA sine <38dBA sine <39dBA sine <39dBA sine <39dBA Common Mode (100k to 1MHz): Normal Mode (100k to 1MHz): Operation Temperature (˚F/˚C): Mechanical -120dB -120dB -120dB -120dB -120dB -60 dB 32 to 104/0 to 40 -60dB 32 to 104/0 to 40 -60dB 32 to 104/0 to 40 -60dB 32 to 104/0 to 40 -60dB 32 to 104/0 to 40 Width (in/mm): Height (in/mm): Depth (in/mm): Weight (lb/kg): Internal Battery Runtime**: Max. Battery Charger Current: Battery Recharge Time: Extended Battery Run Time Options* A. External Battery Pack (EBP): Total Runtime***: B. External Battery Pack (EBP): Total Runtime***: 8.5/216 10/254 20/508 92/42 8.5/216 21/533 22.5/571 151/69 18min 3A 5hrs typical 8.5/216 21/533 22.5/571 171/78 15min 3A 5hrs typical 8.5/216 21/533 22.5/571 185/84 10min 3A 5hrs typical 8.5/216 21/533 29.5/749 283/128 27min 3A 5hrs typical EBP 48A 1hr 39min EBP 48E 3hrs 45min EBP 48A 1hr 10min EBP 48E 2hrs 48min EBP 48A 52min EBP 48E 2hrs 10min EBP 48A 1hr 15min EBP 48E 2hrs 30min Noise Attenuation Indoor Solutions 44 3A 5 hrs typical EBPA EBPA * Factory configured ** Battery runtimes are calculated at 100% load and will vary according to battery age, loads, temperature and other factors. ***Total runtime include the internal batteries and the External Battery Pack (EBP). Agency Compliance EBP Options Marks: CSA 107.1-01, CAN/CSA 601.1-M90 Alpha’s plug-in External Battery Packs provide extended backup for all CFR models. Safety: UL 1778 (2nd Edition), UL Std No 60601-1 (1st Edition) Power Connector Options Longer runtimes are obtained by cascading additional battery cabinets. Input: Hospital Grade NEMA STD: x£x* x£x* xÓä* xÎä* x£x* xÓä* È£x* /iÊÀ>Ê ÊÊÊV È£x* ÈÓä* ÈÓä* /iÊÀ>Ê ÊÊÊV Available for: CFR 1500, 2500, 3000 Output: Hospital Grade NEMA STD: /iÊÀ>Ê ÊÊÊV x£x, x£x, xÓä, ÈÓä, x£x, x£x, xÓä, ÈÓä, Output Power Connector Configuration Options 1) 2) 3) 4) All battery packs are shipped fully assembled and include interconnecting cables. Battery Pack 48V Width (in/mm): Height (in/mm): Depth (in/mm): Weight (lb/kg): Capacity (Ah): EBP 48A 8.5/216 10.5/267 10.5/267 127/58 33 EBP 48E 8.5/216 21.5/546 21.5/546 312/141 88 EBP 1275-48R 22.0/660 30.3/770 31.5/800 905/411 264 Any combination of 3 or less duplex receptacles. Any combination of 2 or less single receptacles. Any duplex receptacle with any single receptacle. Single terminal block. (Other Configurations may be available) Alpha AC Catalogue 2008 For Prin44 44 7/30/2008 3:03:45 PM Three Phase Comet True on-line topology Very high efficiency Transformerless technology Dual input power sources for optimum reliability Digital Power Quality IGBT inverter technology Advanced battery management for maximum battery life Generator friendly Compact footprint Comet Network based software for multi-server control SNMP manageable Graphical User Interface with color touch screen Scalable power levels Whether you are protecting a large server farm or air traffic control tower, the COMET UPS has proven to be the most reliable solution for mid-range power protection applications. The COMET uses a true on-line topology regenerating 100% of the output power to guarantee complete isolation and protection from all utility power problems. Combined with features like 95% efficiency, less than 3.5% output distortion and unique Digital Power Quality IGBT inverter technology the COMET also boasts some of the most favorable specifications of any UPS. Trusted by IT professionals as the industry standard solution, COMET has now become one of the best selling UPSs in its class. 45 Indoor Solutions Alpha AC Catalogue 2008 For Prin45 45 7/30/2008 3:03:46 PM Three Phase Comet Nominal Specifications Model: Output Power: 50 Series 40kVA/32kW Input Voltage (VAC L-L): 208 480 480 600 208 480 480 600 208 480 480 600 208 480 480 600 208 480 480 600 208 480 480 600 208 480 480 600 Output Voltage (VAC L-L): 208 208 480 208 208 208 480 208 208 208 480 208 208 208 480 208 208 208 480 208 208 208 480 280 208 208 480 208 50kVA/40kW 80 Series 65kVA/52kW 150 Series 100kVA/80kW 80kVA/64kW 125kVA/100kW 150kVA/120kW AC Input (With Standard Input Filter) Max. Current (A): 131 57 57 45 164 71 71 56 212 92 92 74 261 113 113 91 301 128 125 107 371 158 154 129 444 182 182 154 111 48 48 39 139 60 60 48 180 78 78 63 222 96 256 109 106 91 ByPass Input Nominal Current (A): 96 77 316 134 130 109 378 160 155 131 AC Output Nominal Current (A): 111 111 48 111 139 139 60 139 180 180 78 180 222 222 96 222 278 278 120 278 347 347 150 347 416 416 180 416 DC Line Nominal Voltage (VDC) @ 25°C: 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 Float Voltage (VDC) @ 25°C: 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 End of Discharge (VDC) @ 25°C: 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 Max. Amps (VDC) @ Cutoff: 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 UPS Mechanical Specifications Depth (in): 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 Depth (cm): 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 Height (in): 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 Height (cm): 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 Single Input1 46 Installed Weight (lb): 1760 1360 880 2460 1760 1360 880 2460 2115 1590 970 2690 2115 1590 970 2690 3400 2450 1450 3400 3400 2450 1450 3400 3400 2450 1450 3400 Installed Weight (kg): 798 617 399 1274 798 617 399 1274 964 721 440 1503 959 721 440 1503 1542 1111 658 1542 1542 1111 658 1542 1542 1111 658 1542 Installed Width (in): 33 33 33 59 33 33 33 59 33 33 33 59 33 33 33 59 Installed Width (cm): 84 84 84 150 84 84 84 150 84 84 84 150 84 84 84 150 175 109 109 175 175 109 109 175 175 109 109 175 Added Installed Weight (lb): 1110 — — 1650 1100 — — 1650 1100 — — 1650 1100 — — 1650 1100 — — 1650 1100 — — 1650 1100 — — 1650 Added Installed Weight (kg): 499 — — 748 499 — — 748 499 — — 748 499 — — 748 726 — — 748 726 — — 748 726 — — 748 Total Installed Width (in): 59 33 33 85 33 33 85 33 33 85 33 33 85 43 95 43 95 43 95 Total Installed Width (cm): 150 84 84 216 150 84 84 216 150 84 84 216 150 84 84 216 241 109 109 241 241 109 109 241 241 109 109 241 @ 100% Load (%): 90 90 93 90 90 90 93 90 91 92 94 91 91 91 94 91 91 93 95 91 90 92 95 90 90 92 94 90 @ 75% Load (%): 90 91 94 90 90 91 94 90 91 92 94 91 91 91 94 91 91 93 95 91 91 93 95 91 90 92 95 90 @ 50% Load (%): 89 90 93 89 89 90 93 89 91 92 94 91 91 91 94 91 89 91 94 89 90 92 94 90 90 93 95 90 69 43 43 69 69 43 43 69 69 43 43 69 Indoor Solutions Dual Input2 59 59 59 95 43 95 43 95 43 System Efficiencies Full Load Heat Dissipation BTU/hr. (x 1000): 16.9 15.2 10.3 16.9 16.9 15.2 10.3 16.9 17.6 15.4 11.3 17.6 21.6 18.9 13.9 21.6 28.3 22.3 15.4 28.3 38.2 30.7 20.8 38.2 50.7 41.6 26.3 50.7 Watts (x 1000): 4.9 4.4 3 4.9 4.9 4.4 3 4.9 5.2 4.5 3.3 5.2 6.3 5.5 4 6.3 8.3 6.5 4.5 8.3 11.2 8.9 6.1 11.2 14.9 12.2 7.7 14.9 Note: Adjacent battery pack width not included with UPS. 1. Single Input feeds both the Bypass and the Inverter. 2. Dual input has separate feed for both the Bypass and the Inverter. Weight to be added. Auxiliary cabinet included where required. Battery Pack Options Runtimes Battery Type NPX 150R: UPS 12-270F: UPS 12-370F: UPS 12-475F: UPS 12-270F: UPS 12-370F: UPS 12-270F: UPS 12-475F: UPS 12-370F: UPS 12-475F: Qty. per Cabinet 36 36 36 36 72 72 108 72 108 108 40kVA (min) 12 28 45 65 73 100 110 150 195 250 50kVA (min) 10 23 36 52 60 80 90 120 156 198 65kVA (min) 6 17 25 36 45 60 72 94 115 145 80kVA (min) — 12 20 28 31 46 56 60 76 92 100kVA (min) — 8 15 19 25 36 42 56 60 69 125kVA (min) — 5 10 13 18 26 31 37 46 60 150kVA (min) — — 7 9 13.5 21 25 30 36 51 Note: Runtimes are listed at full load. Battery Mechanical Specifications: Weight (lb/kg): Width (in/cm): NPX 150R 1878/852 26/66 UPS 12-270F 2750/1247 32/81 UPS 12-30F 3380/1533 48/122 UPS 12-475F 4100/1860 48/122 For additional information about the AlphaSource 6000 (225 to 800kVA) please contact your local sales representative. Alpha AC Catalogue 2008 For Prin46 46 7/30/2008 3:03:48 PM Three Phase Galaxy 4000 Power ranges 40, 50, 65 and 75kVA True online double conversion technology IGBT rectifier Low UPS to generator sizing Power surge stabilization system SNMP and network based power management options Power factor corrected input SNMP and network based power management options The Galaxy 4000 is designed for data center grade power protection in critical environments. Features include fault tolerant architecture to protect loads and the UPS unit during unintended faults, easy and quick to install, user-friendly graphical interface, web Galaxy 4000 based monitoring options, and front only access. The IGBT rectifier minimizes input harmonics and power factor corrected input reduces installation costs due to smaller cabling and generator costs. The Galaxy 4000’s unique fault tolerant architecture safely manager output faults without compromising the UPS, while the Digital Power Quality Management System provides precision voltage regulation on a consistent bases. The UPS is also available as a UL 924 system for emergency lighting applications. 47 RS232/RS485 serial interface Ethernet/SNMP web card connection kit External maintenance bypass with interlock Internal maintenance bypass Seismic brackets Indoor Solutions Optional Features 42 pole distribution Alpha AC Catalogue 2008 For Prin47 47 7/30/2008 3:03:51 PM Three Phase Galaxy 4000 Nominal Specifications Output Power Rating: 40kVA 50kVA 65kVA 75kVA Voltage: 208V 208V 208V 208V Frequency: 60Hz (±5%) 60Hz (±5%) 60Hz (±5%) 60Hz (±5%) Power Factor: >0.98 >0.98 >0.98 >0.98 Current Distortion (THD): >3% >3% >3% >3% Current (A @ 208V): 102 127 166 191 Voltage: 208V 208V 208V 208V Frequency: 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) Transient Response: ±5% for 0 to 100% to 0% ±5% for 0 to 100% to 0% ±5% for 0 to 100% to 0% ±5% for 0 to 100% to 0% Voltage Distortion THD: <1% L-L and L-N <1% L-L and L-N <1% L-L and L-N <1% L-L and L-N Inverter Overload: 130% for 1min 145% for 45sec 130% for 1min 145% for 45sec 130% for 1min 145% for 45sec 130% for 1min 145% for 45sec Bypass Overload: 10x nominal current 10x nominal current 10x nominal current 10x nominal current Output Current (A @ 208V): 111 139 180 208 Heat Rejection (max. BTUs): 14900 18700 24200 28000 1 x 285W/Cell: 12 9 6 - 1 x 370W/Cell: 20 14 9 8 1 x 500W/Cell: 28 22 15 11 2 x 370W/Cell: 47 36 25 22 2 x 500W/Cell: 67 52 38 31 3 x 500W/Cell: 98 85 60 53 4 x 500W/Cell: 136 115 85 72 Dimensions (in): 33.5W x 72.1H x 35.6D 33.5W x 72.1H x 35.6D 33.5W x 72.1H x 35.6D 33.5W x 72.1H x 35.6D (mm): 851W x 1831H x 904D 851W x 1831H x 904D 851W x 1831H x 904D 851W x 1831H x 904D 1235/560 1235/560 1235/560 1235/560 Dimensions (in): 26.5W x 72.1H x 33.5D 26.5W x 72.1H x 33.5D 26.5W x 72.1H x 33.5D 26.5W x 72.1H x 33.5D (mm): 673W x 1831H x 851D 673W x 1831H x 851D 673W x 1831H x 851D 673W x 1831H x 851D 2045/928 2045/928 2045/928 2045/928 Dimensions (in): 33.5W x 72.1H x 33.5D 33.5W x 72.1H x 33.5D 33.5W x 72.1H x 33.5D 33.5W x 72.1H x 33.5D (mm): Input Output Indoor Solutions 48 Runtimes @ 100% Load Mechanical Specifications Standard Cabinet Weight (lb/kg): Battery Cabinet Weight (lb/kg): Second Battery Cabinet 851W x 1831H x 851D 851W x 1831H x 851D 851W x 1831H x 851D 851W x 1831H x 851D Weight (lb/kg): 2745/1245 2745/1245 2745/1245 2745/1245 Standards: ISO 9001, UL 1778, cUL , FCC Part 15, subpart J, Class A, NEMA PE 1, NEMA 250, NFPA 70, IEC 10000 (801) level 4, OSHA Alpha AC Catalogue 2008 For Prin48 48 7/30/2008 3:03:52 PM Three Phase Galaxy 3000 Power ranges 10, 15, 20 and 30kVA True online technology Network-based power management Input Power Factor Correction (PFC) All-in-one complete solution The Galaxy 3000 is the uninterruptible power supply design for mid-range data center enterprise level applications. The Galaxy 3000 delivers the optimum level of reliability, availability and scalability demanded by the new generation of critical enterprise applications. Clearly separated from the crowd by its robust Ultra High Availability Topology (UHAT), the Galaxy reacts to any circumstance in an inherently safe way to protect the critical load. Galaxy 3000 The true all-in-one design incorporates every feature into one compact cabinet, including animated graphical user interface, power factor corrected input, batteries and space for four communication cards. Combined with a scalable design, dual power feed option and generator friendly technology, the AlphaSource Galaxy is truly a quantum leap forward in critical power protection. 49 Optional Features Input distribution management Matching power distribution unit (84 circuits) Digital power quality management system (PWM/IGBT inverter) EIA232 / EIA485 serial interface Step load voltage stabilization Ethernet/SNMP network connection kit Intelligent battery management system Dual input Fault tolerant architecture External maintenance bypass Scalable architecture (10 & 20kVA models) Input isolation transformer No extra cabinet for isolation transformer Indoor Solutions Standard Features Integrated battery bank Low audible noise fans (<53dBA) Casters with leveling feet Network based software for multi-server control Dry contact i/o card SNMP manageable 4 color graphic display with multilingual user interface Bottom or top entry Integrated maintenance bypass Four communications ports 12 month warranty Alpha AC Catalogue 2008 For Prin49 49 7/30/2008 3:03:52 PM Three Phase Galaxy 3000 Nominal Specifications Output Power Rating: 10kVA 15kVA 20kVA 30kVA Voltage: 208/220/480/600 208/220/480/600 208/220/480/600 208/220/480/600 Frequency: 60Hz (-25 to 8%) 60Hz (-25 to 8%) 60Hz (-25 to 8%) 60Hz (-25 to 8%) Power Factor: >0.99 >0.99 >0.99 >0.99 Current Distortion (THD): >3% >3% >3% >3% Current (A @ 208V): 26 46 61 91 Breaker (@ 208): 40 60 80 125 Input Output 50 Voltage: 208 (220/480/600) 208 (220/480/600) 208 (220/480/600) 208 (220/480/600) Frequency; 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) Transient Response: ±3% for 0 to 100% to 0% ±3% for 0 to 100% to 0% ±3% for 0 to 100% to 0% ±3% for 0 to 100% to 0% Voltage Distortion THD: <3% L-L and L-N <3% L-L and L-N <3% L-L and L-N <3% L-L and L-N Inverter Overload: 120% for 1min 120% for 1min 120% for 1min 120% for 1min Bypass Overload: 10x nominal current 10x nominal current 10x nominal current 10x nominal current Output Current (A @ 208V): 28 42 56 83 Heat Rejection (max. BTUs): 4100 6100 8200 12200 11/39/60 7/22/35/55 15/24/38 8/12/21 32.8W x 62.4H x 35.5D 32.8W x 62.4H x 35.5D 32.8W x 62.4H x 35.5D 32.8W x 62.4H x 35.5D 83.8W x 158.5H x 90.2D 83.8W x 158.5H x 90.2D 83.8W x 158.5H x 90.2D 83.8W x 158.5H x 90.2D 2.065/0.94 2.065/0.94 2.065/0.94 2.065/0.94 23W x 48.5H x 33.5D 23 W x 48.5 H x 33.5 D — — 58.4W x 123.2H x 90.2D 58.4W x 123.2H x 90.2D — — 2.065/0.94 2.065/0.94 — — 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 780/353.8 780/353.8 780/353.8 Batteries Backup Time (minutes)1: Indoor Solutions Mechanical Specifications Standard Cabinet Dimensions (in): (cm): Weight (lb/kg): 2 Micro Cabinet3 Dimensions (in): (cm): Weight (lb/kg): Auxiliary Cabinets Maintenance Bypass Cabinet (in): (cm): Output Voltage Transformer (in): (cm): Distribution Cabinet (24 to 42 pole)(in): 23W x 62.4H x 35.5D (cm): 58.4W x 158.5H x 90.2D Weight (lb/kg): 780/353.8 Standards: UL 1778, cUL , FCC Class A parts, 15 sub part J Class A, IEC 1000 level 4, IEEE C62.41-B3, NEC, ISO 9001 11/7min battery times only applicable for micro cabinet. Weight will vary based on battery runtime and input volt options. Micro Cabinet only available in 208/208V. External maintenance bypass distribution options not available with micro cabinet. 1 2 3 Alpha AC Catalogue 2008 For Prin50 50 7/30/2008 3:03:52 PM Electrical Receptacles Receptacle Information Electrical receptacles, outlets, and wall sockets are used in a variety of residential, general-purpose, commercial, industrial, laboratory, and hospital applications. Several blade or pin types are available. Straight (non-locking) electrical receptacles are inserted at a right angle to the plane of the matching device face. By contrast, locking receptacles fix or lock a plug in place when the plug is inserted and then rotated. Electrical receptacles provide maximum voltage and maximum current ratings. Typically, devices are designed for either single-phase or three-phase power. Below are diagrams to help identify plugs and receptacles for your electrical applications NEMA CONFIGURATIONS FOR PLUGS AND RECEPTACLES Non-Locking Plugs and Receptacles 15 Ampere Receptacle Receptacle 50 Ampere 30 Ampere 20 Ampere Plug Plug Receptacle Plug Receptacle Plug 125 V Alpha P/N 5-15R 531-003-10 531-002-10 531-013-10 5-15P 530-001-10 5-20R 531-006-10 5-30R 531-009-10 5-30P 530-005-10 5-50R 531-011-10 5-50P 530-007-10 6-30P 530-006-10 6-50R 531-012-10 6-50P 530-008-10 51 EEMAC Configuration Electrical Receptacles For Canadian Customers Only 5-20P 530-003-10 5-20R 531-005-10 250 V Alpha P/N 6-15R 531-004-10 6-15P 530-002-10 6-20R 531-008-10 For Canadian Customers Only 6-20P 530-004-10 6-30R 531-010-10 EEMAC Configuration 6-20R 531-007-10 Locking Plugs and Receptacles 15 Ampere Receptacle Receptacle 50 Ampere 30 Ampere 20 Ampere Plug Plug Receptacle Plug Receptacle Plug 125 V Alpha P/N L5-15R 531-201-10 L5-15P 530-201-10 X 250 V Alpha P/N 125 / 250 V Alpha P/N Alpha AC Catalogue 2008 For Prin51 51 G L5-20R 531-203-10 X Y L6-15R 531-202-10 Y L5-20P 530-204-10 X G L6-15P 530-202-10 531-203-10 X Y G L6-20R 531-205-10 X Y L5-30P 530-207-10 X G L6-20P 530-206-10 G (Not NEMA Config) 531-208-10 530-209-10 X X Y L6-30R 531-207-10 Y W/Y G L6-30P 530-208-10 X G G W/Y (Not NEMA Config) 531-209-10 530-210-10 X G Y L5-30R 531-206-10 G W L14-20R W Y L14-20P 530-205-10 7/30/2008 3:03:53 PM Service Building upon its suite of products, Alpha now offers a range of service solutions designed to meet your needs. Extended Warranty: Alpha extended warranties are available from the time of initial purchase through to the expiry of the product’s original warranty period. One or three year extensions offer all the terms and conditions of the original equipment warranty, for both the UPS and batteries in your system, with battery coverage offered on a prorated basis due to the nature of wear they sustain over time. To purchase an extended warranty, or to make a claim against the initial product warranty, you will first need to ensure your products are registered. Additionally, product registration automatically extends your initial warranty period for an additional three months. Please note extended warranties are only available to the original registered purchaser. Register your products at www. alpha.com/productregistration Field Service Contracts: Enjoy convenience and peace-of-mind with an annual, prepaid, on site service plan and ensure all your service needs throughout the year are covered. Alpha offers two levels of service plans: 52 Alpha Basic Plan: A trained Alpha field service representative is available to you during regular business hours and will respond to service requests at your location by the next business day. Service Alpha Emergency Plan: An Alpha field service representative is available to you during regular business hours and will respond to service requests at your location within four hours (not available in all areas). Whether you choose the Alpha Basic Plan or the Alpha Emergency Plan you can rest assured you are covered. Alpha service plans ensure the people and parts will always be on hand. to provide the services you need when you need them most (not available in all areas). Both service plans include: • Unlimited technical phone support • All parts and labor • Travel expenses • All costs associated with equipment service * battery replacement is offered on a prorated basis due to the nature of wear they sustain over time Optional Coverage: The purchase of an extended warranty or field service contract also enables you to benefit from valuable service options. Scheduled Preventative Maintenance ensures your backup solutions are always operating at optimum levels. An annual preventative maintenance visit from an Alpha representative includes: • Confirm proper installation of UPS • Clean or replace air filters • Test individual cells for voltage and impedance • Clean, inspect and test complete solution (inverters, transformers, switches and other components) • Perform thermal scan of solution using IR thermographs Battery Renewal allows you to budget for battery replacement. When your batteries need replacing, Alpha will cover the cost. Our Commitment: Alpha Technologies is committed to providing service programs that ensure power integrity throughout the service life of you Alpha product. Alpha AC Catalogue 2008 For Prin52 52 7/30/2008 3:03:53 PM Selection Guide Uninterruptible Power Supply Selection Guide To help us design an Uninterruptible Power Supply (UPS) solution for your specific application, please review the following questions prior to contacting your Alpha representative. Type of Application: PBX, Cell Site, Server, Traffic, Parking, Security, Medical or other. Environment: Indoor: Controlled environment, air conditioned, dust free Outdoor: Non-controlled environment Minimum ambient temperature surrounding the UPS Maximum ambient temperature surrounding the UPS Geographic Location where the UPS is located (Country, City/Town) Power Requirements: Volt-amps (VA) or Watts required by load Input voltage to UPS and Output voltage(s) to load Frequency (Hz) 50 or 60 Backup Time Required: The amount of time in hours or minutes the UPS will operate on batteries when the utility power fails Mounting Configuration: For Indoor Applications: Rack, Tower For Outdoor Applications: Pole, Ground (Is a pedestal required?), or Wall Configuration Requirements: Input plug type or terminal block Output receptacle types or terminal block Accessories: Bypass Switch (Auto/Manual), Ethernet/SNMP, Battery Heater Mats, Battery Management System Warranty: Is extended warranty required? Special servicing needs? Quantities: Number of units required and when Alpha Technologies Ltd. 4084 McConnell Court Burnaby BC V5A 3N7 Canada + 1 800 667 8743 (toll free) + 1 604 430 1476 (Canada) + 1 360 647 2360 (USA) www.alpha.com member of The Argus Technologies USA/Canada + 1 604 436 5900 Alpha Technologies Europe Ltd. Alpha Technologies GmbH AlphaTec Ltd. United Kingdom Germany Republic of Cyprus +44 1279 501110 + 49 9122 79889 0 +357 25 375675 Alphatec Baltics Lithuania +370 5 213 8822 Visit www.alpha.com for additional information. Alpha Technologies Due to continuing product development, Alpha reserves the right to change specifications without notice. Copyright © 2008 Alpha Technologies Inc. All Rights Reserved. Alpha is a registered trademark of Alpha Technologies. 048-160-10 (07/2008) Alpha Technologies France +33 141 900 707 Group™ AlphaTEK ooo Russia +7 495 916 1854 Alpha Technologies PR China +852 2736 8663