ELECTRICAL SYMBOLS AND ABBREVIATIONS NOTE: NOT ALL SYMBOLS AND ABBREVIATIONS INDICATED HERE ARE USED IN THE DRAWINGS AND MAY NOT APPLY TO THIS PROJECT. ADDITIONAL SYMBOLS MAY BE INDICATED IN THE DRAWINGS. ONE POLE TWO POLE THREE POLE FOUR POLE ONE POLE, ONE WIRE ONE POLE, TWO WIRE TWO POLE, TWO WIRE TWO POLE, THREE WIRE THREE POLE, TWO WIRE THREE POLE, THREE WIRE THREE POLE, FOUR WIRE FOUR POLE, FOUR WIRE AMPERE ALTERNATING CURRENT AMP FRAME ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERE INTERRUPTING CAPACITY ALUMINUM AMP SWITCH AMP TRIP ARCHITECT AUTOMATIC TRANSFER SWITCH AUDIO VISUAL PEDESTAL MOUNTED ON BENCH TOP BELOW FLOOR BUILDING CONDUIT CATALOG CABLE TELEVISION CIRCUIT BREAKER CIRCUIT CEILING MOUNTED CURRENT TRANSFORMER COPPER CENTERLINE DEDICATED DEVICE DIRECT CURRENT DELTA DISC DISCONNECT DWG DRAWING E EMERGENCY EC ELECTRICAL CONTRACTOR EMT ELECTRIC METALLIC TUBING EWC ELECTRIC WATER COOLER EX EXISTING FLA FULL LOAD AMPS GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GFPE GROUND FAULT PROTECTION EQUIPMENT GND GROUND GRC GALVANIZED RIGID CONDUIT HP HORSEPOWER HVAC HEATING, VENTILATING AND AIR CONDITIONING Hz HERTZ (cycle) PER SECOND JB JUNCTION BOX KVA KILOVOLT AMPERE KVAR KILOVOLT AMPERE REACTIVE KW KILOWATT LP LIGHTING PANELBOARD LS LIMIT SWITCH LTG LIGHTING LV LOW VOLTAGE MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MISC MISCELLANEOUS MLO MAIN LUGS ONLY MTD MOUNTED MTG MOUNTING MTS MANUAL TRANSFER SWITCH N/A NOT APPLICABLE NC NORMALLY CLOSED NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NO NORMALLY OPEN # NUMBER NTS NOT TO SCALE OH OH P POLE PB PULL BOX PC PLUMBING SYSTEM CONTRACTOR PH PHASE PNL PANELBOARD PR PAIR PRI PRIMARY PVC POLYVINYL CHLORIDE CONDUIT R RELAY REC RECESSED RSC RIGID STEEL CONDUIT SEC SECONDARY SN SOLID NEUTRAL SP SPARE SS STAINLESS STEEL ST SHUNT TRIP STP SHIELDED TWISTED PAIR SUSP SUSPENDED SW SWITCH SWBD SWITCHBOARD T TAMPER RESISTANT SAFETY RECEPTACLE TC TELEPHONE CABINET TCI TELECOMMUNICATIONS CABLING INSTALLER TEL/DATA TELEPHONE/DATA TEL TELEPHONE TYP TYPICAL UG UNDERGROUND UTP UNSHIELDED TWISTED PAIR V VOLT UOI UNLESS OTHERWISE INDICATED Y WYE W WATT WP WEATHERPROOF XFMR TRANSFORMER ZAM ZONE ADAPTER MODULE +72 MOUNTING UNITS TO CENTERLINE ABOVE FINISHED FLOOR OR GRADE LIGHTING AND CONTROLS 1P 2P 3P 4P 1P1W 1P2W 2P2W 2P3W 3P2W 3P3W 3P4W 4P4W A AC AF AFF AFG AIC AL AS AT ARCH ATS A/V B BF BLDG C CAT CATV CB CKT CLG CT CU CL D DC SURFACE MOUNTED LIGHT FIXTURES POWER AND COMMUNICATIONS G HN GENERAL NOTES CIRCUIT HOME RUN WITH GROUND, HOT, NEUTRAL 1. CIRCUIT TO BE PULLED THROUGH DESIGNATED RELAY IN LIGHTING CONTROL PANEL (IF APPLICABLE) ALL WORK SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER AND AND SHALL COMPLY WITH ALL ADOPTED LOCAL, STATE, AND NATIONAL CODES. 2. ALL ELECTRICAL WORK REQUIRES CITY INSPECTION. ELECTRICAL WORK COVERED OR ENCLOSED PRIOR TO CITY INSPECTION SHALL BE UNCOVERED FOR INSPECTION AND REPLACED AT NO EXPENSE TO THE OWNER. 3. ALL CONDUITS MUST CONTAIN A GROUND WIRE. USE OF THE CONDUIT BODY AS A GROUNDING METHOD IS PROHIBITED. 4. ALL CONDUITS SHALL BE INSTALLED PARALLEL AND/OR PERPENDICULAR TO BUILDING LINES. 5. ALL CONDUCTORS SHALL BE COPPER UNLESS SPECIFIED OTHERWISE. 6. DO NOT SCALE THE DRAWINGS. 7. ELECTRICAL CONDUITS AND/OR CIRCUITS PENETRATING FIRE RATED CEILING AND WALLS TO BE SEALED FIRE AND SMOKE TIGHT AT THE PENETRATION. 8. THE CONTRACTOR SHALL REPLACE AND/OR REPAIR ALL WALLS, CEILINGS, DOORS, EQUIPMENT, WIRING, CONDUIT, ETC, WHICH ARE DAMAGED OR REMOVED BY CONTRACTOR TO THE SATISFACTIONS OF THE ARCHITECT/ENGINEER. 9. ALL MATERIALS SHALL BE NEW AND UNUSED, AND OF THE BEST QUALITY. ALL MATERIAL INSTALLED SHALL BE IL LISTED OR AS REQUIRED BY LOCAL BUILDING CODES. HA1-1,3,5/R1 RECESS MOUNTED LIGHT FIXTURES CIRCUITING INFORMATION FOR GROUPING PURPOSES ONLY. CONTRACTOR SHALL SELECT ACTUAL CIRCUIT BREAKERS AND BALANCE LOADS IN PANELBOARD. PANELBOARD INFORMATION. SEE SCHEDULING SHEETS FOR MORE INFORMATION. WALL MOUNTED LIGHT FIXTURES DUPLEX RECEPTACLE - MOUNTED 18" AFF UNLESS OTHERWISE NOTED SUSPENDED, PENDENT, CHAIN STEM, OR CABLE HUNG LIGHT FIXTURES TAMPER PROOF DUPLEX RECEPTACLE - MOUNTED 18" AFF UNLESS OTHERWISE NOTED SHADING INDICATES FIXTURE FULLY WIRED TO EMERGENCY OR NIGHT LIGHTING CIRCUIT GFCI DUPLEX RECEPTACLE - MOUNTED 18" AFF UNLESS OTHERWISE NOTED DUPLEX RECEPTACLE - MOUNTED 6" ABOVE COUNTER BACKSPLASH UNLESS OTHERWISE NOTED PARTIAL SHADING INDICATES FIXTURE PARTIALLY WIRED TO EMERGENCY OR NIGHT LIGHTING CIRCUIT QUAD RECEPTACLE MOUNTED 18" AFF UNLESS OTHERWISE NOTED STRIP OR UNDER CABINET LIGHT FIXTURE DUPLEX RECEPTACLE MOUNTED FLUSH IN CEILING SINGLE HEAD SPOT LIGHT OR FLOOD LIGHT FIXTURE X DOUBLE HEAD SPOT LIGHT OR FLOOD LIGHT FIXTURE FLOOR MOUNTED ELECTRICAL BOX SEE DRAWINGS FOR TYPES OF OUTLETS REQUIRED AT EACH BOX (F) FLUSH TYPE (P) POKE THRU TYPE PUSHBUTTON EXIT LIGHT FIXTURE ARROWS AND FACE AS INDICATED ON DRAWINGS SPECIAL PURPOSE OUTLET - THIS ELECTRICAL CONNECTION REQUIRES ONSITE COORDINATION WITH OTHER CONTRACTORS AND/OR VENDORS PRIOR TO INSTALLATION. PROVIDE ALL CONNECTIONS, MOTOR STARTERS, AND DISCONNECTS REQUIRED BY CODE AND FINAL SUGGESTED MANUFACTURER REQUIREMENTS. CONTACT ENGINEER WITH ANY REQUIRED CHANGES TO ELECTRICAL DESIGN. LIGHTING TRACK LENGTH AS INDICATED ON DRAWING NUMBER OF FIXTURES AS INDICATED ON DRAWING AND/OR LIGHT FIXTURE SCHEDULE EMERGENCY BATTERY REMOTE LIGHTING HEADS 2 EMERGENCY BATTERY UNIT WITH LIGHTING HEADS PANELBOARD - FLUSH MOUNTED SURFACE MOUNTED ACCENT LIGHT PANELBOARD - SURFACE MOUNTED RECESS MOUNTED ACCENT LIGHT TRANSFORMER MOUNT ON 4" PAD UNLESS OTHERWISE NOTED HT S K SINGLE POLE SWITCH MOUNT 44" AFF UNLESS OTHERWISE NOTED SWITCH DESIGNATION SWITCH TYPE (2) DOUBLE POLE (3) 3 WAY (4) 4 WAY (K) KEY OPERATED (P) WITH PILOT LIGHT INDICATION (DL) DUAL LEVEL SWITCH (VC) VACANCY SENSOR LUTRON MS-OPS6M2-DV-WH (D) LUTRON MAESTRO WIRELESS DIMMER R1 MOTOR CONNECTION (2) MOTOR IDENTIFICATION PB 10. VERIFY VOLTAGE, CURRENT AND PHASES FOR ALL EQUIPMENT TO BE INSTALLED INCLUDING BY OWNER. 11. THE CONTRACTOR SHALL PROVIDE ALL FUSES AND CIRCUIT BREAKERS WHERE REQUIRED BY THE NEW CONSTRUCTION DOCUMENTS. 12. ALL ELECTRICAL CABINETS, PANELS, DISCONNECTS, TRANSFORMERS, CONTROLS, RECEPTACLES, J-BOXES, ETC., SHALL BE MARKED, TAGGED AND IDENTIFIED. NOTE FEEDER SOURCE WHERE APPLICABLE. 13. CONTRACTOR SHALL PROVIDE ALL MATERIALS EXCEPT AS NOTED AND MAKE ALL NECESSARY CONNECTIONS TO NEWLY INSTALLED EQUIPMENT. 14. UPON COMPLETION OF THE PROJECT, ALL CHANGES SHALL BE DOCUMENTED, AND REDLINED. AS-BUILT DRAWINGS SHALL BE TURNED OVER TO THE OWNER BY THE CONTRACTOR. 15. 4" HOUSEKEEPING CONCRETE PADS SHALL BE FURNISHED FOR ALL FLOOR MOUNTED EQUIPMENT, BY OTHERS. 16. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID TO VERIFY EXISTING CONDITIONS. BY SUBMITTING A BID THE CONTRACTOR ACKNOWLEDGES THAT HE HAS VISITED THE SITE AND THE BID IS ADEQUATE TO PERFORM WORK NECESSARY TO MAKE THE SYSTEMS COMPLETE AND OPERATIONAL. IF THE CONDITIONS AT THE SITE ARE NOT SUCH THAT THE WORK CAN BE INSTALLED AS SHOWN, CONTRACTOR'S BID SHALL INCLUDE COST, TO COVER NECESSARY ADJUSTMENTS AND ADDITIONS, (BASED ON SITE CONDITIONS) TO MAKE THE SYSTEMS COMPLETE AND OPERATIONAL. CONTRACTOR TO CONTACT ARCHITECT/ENGINEER WITH ANY FIELD DISCREPANCIES. IN-GRADE PULLBOX DISCONNECT SWITCH FUSED DISCONNECT SWITCH COMBINATION MOTOR STARTER LOW VOLTAGE SWITCH OVERIDE HOUSTON, TX 77XXX ELECTRICAL ABBREVIATIONS MOTOR RATED SWITCH RELAY DESIGNATION VC LIGHTING CONTROL VACANCY SENSOR-CEILING MOUNTED LUTRON LRF2-OCR2B-P-WH T TIME CLOCK - SEE SCHEDULE ON SHEET# C CONTACTOR - SEE SCHEDULE ON SHEET# PC J EPO DOUBLE ACTION MUSHROOM HEAD EMERGENCY POWER OFF BUTTON. THIS BUTTON SHALL PROVIDE A SIGNAL TO SHUNT TRIP ALL CIRCUIT BREAKERS WHICH FEED POWER TO THIS ROOM. ALL CIRCUIT BREAKERS FEEDING THIS ROOM SHALL BE SHUNT TRIP TYPE. SHEET: ELECTRICAL SYMBOLS & ABBREVIATIONS PHOTO CELL LCP/1 DESIGNATION REVISIONS: TELEPHONE/DATA OUTLET - PROVIDE SINGLE GANG BOX AND 1" CONDUIT WITH PULL STRING TO NEAREST ACCESSIBLE CEILING. LIGHTING CONTROLLER PANEL LCP 1 JUNCTION BOX PNL PANELBOARD DESIGNATION 11/21/14 PM: / PC: DATE: 09-24-14 PROJECT: CIVIL STRUCTURAL MEP TECHNOLOGY 1250 Wood Branch Park, Suite 210, HOUSTON TX 77079 office: 281-293-7500 www.dvoeng.com REGISTRATION NO. F-8334 SHEET: E.0 LB-1 HB-1 ELECTRICAL SERVICE LOCATION TLB HB LB WP THRU LIGHTING CONTROLS B B KE B B C CE C B HOUSTON, TX 77XXX C CE B SHEET: ELECTRICAL FLOOR PLAN REVISIONS: FLOOR PLAN - ELECTRICAL SCALE 1/8"= 1'0" 11/21/14 PM: / PC: DATE: 09-24-14 PROJECT: CIVIL STRUCTURAL MEP TECHNOLOGY 1250 Wood Branch Park, Suite 210, HOUSTON TX 77079 office: 281-293-7500 www.dvoeng.com REGISTRATION NO. F-8334 SHEET: E.1 SERVICE FEEDERS UNDERGROUND TO POWER COMPANY XFMR 2 SETS OF 3"C WITH 4 - 350MCM THWN COPPER LETTER (FILL) COLOR: NORMAL = WHITE EQUIPMENT DESIGNATION NAMEPLATE COLOR: NORMAL = BLACK INDICATE VOLTAGE, # OF PHASES, # OF WIRES SHORT CIRCUIT RATINGS ARE CALCULATED USING POINT TO POINT METHOD. M A PERMANENTLY AFFIXED LABEL SHALL BE APPLIED WITH THE AVAILABLE FAULT CURRENT AT THE TIME OF THE CALCULATION. THE LABEL SHALL BE 2" X 3" IN SIZE AND SHALL BE BLUE LETTERING ON A CONTRASTING BACKGROUND. THIS LABEL SHALL ALSO INCLUDE THE DATE OF CALCULATION PER 2011 COH ELECTRICAL CODE 504.1.1. CT CAN PT 600A FUSED DISC HOUSE PANEL XXX XXX / XXXV, XXXPH, XXXW FED FROM XXX, BREAKER XXX ATTACH NAMEPLATE WITH (2) SCREWS INDICATE WHERE EQUIPMENT IS FED FROM LETTERING SHALL BE 1/4" HIGH AVAILABLE AIC: 20936 PANELBOARD NAMEPLATE DETAIL NTS N G #4/0 MAIN BONDING JUMPER PER NEC 250.28 #1/0 THWN COPPER GROUNDING ELECTRODE CONDUCTOR PER TABLE 250.66 NEC PROVIDE ADDITIONAL GROUNDING AS REQUIRED BY ARTICLE 250.30 NEC 2 SETS OF 3"C WITH 4 - 350MCM, 1 - #1 GND THWN COPPER ASTRONOMICAL TIME SWITCH, PHOTO CELL & CONTACTOR CABINET AVAILABLE AIC: 20833 HB STEEL BUILDING, SEE NEC 250-81(b) GROUND BUS IN MDP 1 1/2"C WITH 3 - #1, 1 - #6 GND THWN COPPER 1 COLUMN FOOTING WATER SERVICE PIPE, SEE NEC 250-81(a) 3 INSTALL CONDUCTOR PER NEC ARTICLE 250-81(c) NEUTRAL BUS IN MDP 3 AVAILABLE AIC: 20208 3 TLB 75KVA 480V, 3PH, 3W PRI 208Y / 120V, 3PH, 4W SEC Y 10" x 3/4" GROUND ROD, SEE NEC 250-83(c) KEYED NOTES: 2 1/2"C WITH 4 - 4/0, 1 - #2 GND THWN COPPER 1 2 AVAILABLE AIC: 3743 3 LB DETAIL NOTES: BARE COPPER MAIN BONDING JUMPER PER NEC 250-53(b). 1. BARE COPPER GROUNDING ELECTRODE CONDUCTOR PER NEC 250-23(a). 2. BARE COPPER GROUNDING ELECTRODE BONDING JUMPER PER NEC 250-81. COLUMN FOOTING 3. INSTALL CONDUCTORS IN CONDUITS, CONDUIT TYPE SHALL BE PVC PER SPECIFICATIONS. SIZE ALL GROUND CONDUCTORS IN ACCORDANCE WITH NEC. EC SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF NEC ARTICLE 250. HOUSTON, TX 77XXX #2 CU 3 2 PROGRAMMABLE LIGHTING CONTROLLER GROUNDING ELECTRODE SYSTEM DETAIL NTS ELECTRICAL ONE-LINE DIAGRAM SHEET: NTS ELECTRICAL ONE-LINE AND DIAGRAMS REVISIONS: 11/21/14 PM: / PC: DATE: 09-24-14 PROJECT: CIVIL STRUCTURAL MEP TECHNOLOGY 1250 Wood Branch Park, Suite 210, HOUSTON TX 77079 office: 281-293-7500 www.dvoeng.com REGISTRATION NO. F-8334 SHEET: E.2 LIGHT FIXTURE SCHEDULE MARK MANUFACTURER AND MODEL VOLTAGE LAMPS INPUT WATTAGE MOUNTING B LUMARK MHWL 277 250W PSMH COATED 265 SURFACE OUTDOOR METAL HALIDE WALL LUMINAIRE KE HUBBELL - QSP-84FI-WT-BZ-BOC(4) 277 2/42W CFL 84 SURFACE OUTDOOR CFL EMERGENCY FIXTURE C HALO - PD6H142E-62HC 277 1/42W CFL 52 RECESSED 6" DIA., COMPACT (6 \" H), DOWNLIGHT WITH SPECULAR. ALL RECESSED CANS MUST BE 4100K COLOR TEMP. UL LISTED FOR DAMP LOCATION. INCLUDE COLD WEATHER BALLAST 1/42W CFL 52 RECESSED 6" DIA., COMPACT (6 \" H), DOWNLIGHT WITH SPECULAR. ALL RECESSED CANS MUST BE 4100K COLOR TEMP. UL LISTED FOR DAMP LOCATION. EMERGENCY BATTERY BACK UP AND COLD WEATHER BALLAST GENERAL NOTES SAME AS 'C' WITH EMERGENCY BATTERY BACKUP 277 1. CONFIRM BUILDING STANDARD LAMP COLOR TEMPERATURE WITH OWNER'S REPRESENTATIVE. HOUSTON, TX 77XXX CE DESCRIPTION SHEET: ELECTRICAL SCHEDULES & LOAD ANALYSIS REVISIONS: 11/21/14 PM: / PC: DATE: 09-24-14 PROJECT: CIVIL STRUCTURAL MEP TECHNOLOGY 1250 Wood Branch Park, Suite 210, HOUSTON TX 77079 office: 281-293-7500 www.dvoeng.com REGISTRATION NO. F-8334 SHEET: E.3 PLUMBING SYMBOLS AND ABBREVIATIONS NOTE: NOT ALL SYMBOLS AND ABBREVIATIONS INDICATED HERE ARE USED IN THE DRAWINGS AND MAY NOT APPLY TO THIS PROJECT. ADDITIONAL SYMBOLS MAY BE INDICATED IN THE DRAWINGS. AB ACC ADJ. AFF AFG ALT AP APPROX. ARCH ASSY AVG ABOVE ACCESS ADJUSTABLE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ALTERNATE ACCESS PANEL APPROXIMATELY ARCHITECTURAL ASSEMBLY AVERAGE BFF BLDG BOT BOP BT BTU BTUH BELOW FINISHED FLOOR BUILDING BOTTOM BOTTOM OF PIPE BATHTUB BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BETWEEN BTW CAP CFCI CTR CU CW CWFU CEILING ACCESS PANEL CONTRACTOR FURNISHED, CONTRACTOR INSTALLED CUBIC FEET PER MINUTE CUBIC FEET PER HOUR CENTERLINE CEILING CONCRETE MASONRY UNIT CLEANOUT CONDUCTOR CONTRACTOR COEFFICIENT OF PERFORMANCE CENTER COPPER COLD WATER COLD WATER FIXTURE UNITS DD DEG DET DFU DIA DIM DN DS DT DWG. DRAIN DECK DEGREES DETAIL DRAINAGE FIXTURE UNITS DIAMETER DIMENSION DOWN DOWNSPOUT DRAIN TILE DRAWING E EA EC EEW EFF. EJ ELEC ELEV EM EQUIP ES ET ETR EWC EWH EWT EXH EXP EXST EXT EXISTING EACH ELECTRICAL CONTRACTOR EMERGENCY EYEWASH EFFICIENCY EXPANSION JOINT ELECTRICAL ELEVATION EMERGENCY EQUIPMENT EMERGENCY SHOWER EXPANSION TANK EXISTING TO REMAIN ELECTRIC WATER COOLER ELECTRIC WATER HEATER ENTERING WATER TEMPERATURE EXHAUST EXPANSION EXISTING EXTERIOR F FCO FD FFE FLA FLR FM FP FPM FPS F&T FT FTG FU FUTURE FLOOR CLEANOUT FLOOR DRAIN FINISHED FLOOR ELEVATION FULL LOAD AMPS FLOOR FACTORY MUTUAL FIREPROOF FEET PER MINUTE FEET PER SECOND FLOAT AND THERMOSTATIC FEET FOOTING FIXTURE UNITS GA GAL GALV GC GPM GPH GAUGE GALLON GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GALLONS PER HOUR HB HD HP H.P. HVAC HW HWFU HOSE BIBB HUB DRAIN HORSE POWER HIGH POINT HEATING, VENTILATING & AIR CONDITIONING HOT WATER HOT WATER FIXTURE UNITS ID IE IN INSIDE DIAMETER INVERT ELEVATION INCHES KO KNOCK-OUT L LBS. LB/HR L.F. LP LTG LWT LAVATORY POUNDS POUNDS PER HOUR LINEAR FEET LOW POINT LIGHTING LEAVING WATER TEMPERATURE CFH CFM CL CLG CMU CO COND CONT COP MAX MB MBH MC MCA MCC MEP PIPING SYSTEMS LABELS MER MEZZ MFR MH MIN. MISC MTD MTG MAXIMUM MOP BASIN THOUSANDS OF BTU PER HOUR MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MECHANICAL, ELECTRICAL AND PIPING MECHANICAL EQUIPMENT ROOM MEZZANINE MANUFACTURER MANHOLE MINIMUM MISCELLANEOUS MOUNTED MOUNTING NA NIC NO NPS NPSH NPT NR NTS NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL PIPE SIZE NET POSITIVE SUCTION HEAD NATIONAL PIPE THREAD NEAR NOT TO SCALE OC OD OFCI OLP OV ON CENTER OUTSIDE DIAMETER OWNER FURNISHED, CONTRACTOR INSTALLED OWNER FURNISHED, OWNER INSTALLED OVERLOAD PROTECTION OUTLET VELOCITY P PC PCF PD PH PIV PLBG POC PP PPH PRV PSF PSI PSIA PSIG PVC PUMP PLUMBING CONTRACTOR POUNDS PER CUBIC FOOT PRESSURE DROP PHASE POST INDICATOR VALVE PLUMBING POINT OF CONNECTION POLYPROPYLENE POUNDS PER HOUR PRESSURE RELIEF VALVE POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH ABSOLUTE POUNDS PER SQUARE INCH GAUGE POLYVINYL CHLORIDE RAD RCP RD REC RECPT REQD RF RI RPM RPZ RV RADIUS REINFORCED CONCRETE PIPE ROOF DRAIN RECESSED RECEPTACLE REQUIRED ROOF ROUGH-IN REVOLUTIONS PER MINUTE REDUCED PRESSURE ZONE VALVE RELIEF VALVE S SCH SDR SH SHT SOG SPEC SQ SS S/S STD STRU SLOPE SCHEDULE STANDARD DIMENSION RATIO SHOWER SHEET SLAB ON GRADE SPECIFICATION SQUARE SERVICE SINK STAINLESS STEEL STANDARD STRUCTURAL T&P TBR TD TDFU TEMP TOB TOD TOJ TOP TOS T STAT TWFU TYP TEMPERATURE AND PRESSURE TO BE REMOVED TRENCH DRAIN TOTAL DRAIN FIXTURE UNITS TEMPERATURE TOP OF BEAM TOP OF DUCT/DECK TOP OF JOIST TOP OF PIPE TOP OF SLAB THERMOSTAT TOTAL WATER FIXTURE UNITS TYPICAL UNO UNLESS OTHERWISE NOTED V VEL VIB VOL VENT VELOCITY VALVE IN BOX VOLUME W W/ W/O WC WSFU WG WIDTH WITH WITHOUT WATER COLUMN WATER SUPPLY FIXTURE UNITS WATER GAUGE OFOI WATER PIPING SYSTEMS: SCW F PIPING VALVES AND SPECIALTIES GAS AND AIR PIPING SYSTEMS: COLD SOFT WATER A COLD WATER H2 HYDROGEN FIRE PROTECTION G NATURAL GAS HOT WATER N2 NITROGEN VAC HOT WATER RETURN NPW TW RO COMPRESSED AIR GENERAL NOTES ANGLE VALVE AIR VENT, AUTOMATIC BALANCING VALVE AIR VENT, MANUAL BALL VALVE BUTTERFLY VALVE BACKFLOW PREVENTER CONSTANT FLOW REGULATOR 1. ALL WORK SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER AND AND SHALL COMPLY WITH ALL ADOPTED LOCAL, STATE, AND NATIONAL CODES. 2. DO NOT SCALE THE DRAWINGS. 3. FIELD VERIFY EXACT LOCATION OF ALL CONNECTION POINTS PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL INSPECT SITE THOROUGHLY TO FAMILIARIZE THEMSELVES WITH THE AREA OF WORK. ANY DISCREPANCIES BETWEEN THESE DOCUMENTS AND ACTUAL CONDITIONS SHALL BE REPORTED TO THE ARCHICTECT/ENGINEER FOR RESOLUTIONS PRIOR TO BID PRICING. NO EXTRAS WILL BE ALLOWED DUE TO LACK OF KNOWLEDGE OF EXISTING OR NEW CONDITIONS. 5. PROVIDE BALL VALVES ON ALL BRANCH LINES FOR BUILDING ISOLATION WHETHER SHOWN OR NOT. 6. OFFSET ALL PIPING AS REQUIRED TO AVOID STRUCTURAL MEMBERS, CANTS, FLASHING, MECHANICAL OR ELECTRICAL EQUIPMENT. VACUUM (AIR) NON-POTABLE WATER CHECK VALVE DEMOLITION OF PIPING, DEVICE, ETC. DIAPHRAGM VALVE DIRECTION OF FLOW TEMPERED WATER REVERSE OSMOSIS WATER DRAIN VALVE DIRECTION OF PITCH RISE (R) OR DROP (D) FLOAT OPERATED VALVE WASTE AND VENT SYSTEMS: SITE PIPING SYSTEMS: CD CONDENSATE DRAIN F CWV CLEARWATER VENT FM CWW CLEARWATER WASTE SAN GAS SHUTOFF VALVE EXPANSION JOINT FIRE MAIN FORCE MAIN SANITARY SEWER FM FORCE MAIN ST STORM SEWER IW INDIRECT WASTE W WATER LINE OD OVERFLOW DRAIN LINE ST STORM SSD DRAIN PLUG GATE VALVE FLEXIBLE CONNECTION GLOBE VALVE FLOW SWITCH PLUG VALVE FLOW SENSING DEVICE POST INDICATOR VALVE GAS REGULATOR PRESSURE REDUCING VALVE GAS OUTLET SUBSOIL DRAIN LINE UNDERFLOOR FOR WASTE OR SOIL, SUBSOIL, STORM & FORCE MAIN VENT SAN WASTE OR SOIL LINE PRESSURE RELIEF VALVE NOTE: (E) PRIOR TO SYSTEM TYPE DENOTES EXISTING PIPING (F) PRIOR TO SYSTEM TYPE DENOTES FUTURE PIPING QUICK OPENING VALVE HOSE BIBB PETE'S PLUG SHUTOFF VALVE PRESSURE GAUGE PIPE FITTINGS SOLENOID VALVE PRESSURE SWITCH FLANGE ELBOW DOWN UNION ELBOW UP ANCHOR TEE DOWN PIPE GUIDE TEE UP ECCENTRIC REDUCER PIPE CAP CONCENTRIC REDUCER VALVE IN VERTICAL TEE BRANCH DOUBLE WYE TRIPLE DUTY VALVE STEAM TRAP 2-WAY CONTROL VALVE (VALVE BODY AS SPECIFIED) THERMOMETER LINE CONTINUATION BREAK PLUMBING FIXTURE STOPS WYE 3-WAY MIXING VALVE WALL HYDRANT 4-WAY VALVE WITH ARROW INDICATING FAIL POSITION WATER HAMMER ARRESTOR WYE WITH VENT UP VALVE IN BOX PIPELINE STRAINER DRAINS AND CLEANOUTS FLOOR DRAIN FIXTURE WASTE TRAP ROOF DRAIN CLEANOUT HUB DRAIN FLOOR CLEANOUT HOUSTON, TX 77XXX PLUMBING ABBREVIATIONS SHEET: PLUMBING SYMBOLS & ABBREVIATIONS REVISIONS: 11/21/14 PM: / PC: DATE: 09-24-14 PROJECT: CIVIL STRUCTURAL MEP TECHNOLOGY 1250 Wood Branch Park, Suite 210, HOUSTON TX 77079 office: 281-293-7500 www.dvoeng.com REGISTRATION NO. F-8334 SHEET: P.0 WALL HYDRANT WITH VACUUM BREAKER. 4" SS WITH DOUBLE GROUND CLEAN OUT, REFERENCE CIVIL. 2" CW REFERENCE CIVIL. 3" VTR, OFFSET AT ROOF. 2" COLD WATER STUB UP AND PROVIDE WITH SHUT-OFF VALVE IN HORIZONTAL. 4"SS SANITARY SEWER PIPE TO BE INSTALLED WITH A MINIMUM SLOPE OF 1/4" PER 1 FOOT SLOPE (2%). FCO 4"SS HOUSTON, TX 77XXX 3" VTR, OFFSET AT ROOF. GCO WALL HYDRANT WITH VACUUM BREAKER. SHEET: PLUMBING FLOOR PLAN REVISIONS: FLOOR PLAN - PLUMBING BUILDING 2 SCALE 1/8"= 1'0" 11/21/14 PM: / PC: DATE: 09-24-14 PROJECT: CIVIL STRUCTURAL MEP TECHNOLOGY 1250 Wood Branch Park, Suite 210, HOUSTON TX 77079 office: 281-293-7500 www.dvoeng.com REGISTRATION NO. F-8334 SHEET: P.1 EXTERIOR WALL BUILDING SERVICE WALL HYDRANT WP SLEEVE COLD WATER PIPING (UNDERGROUND) COLD WATER PIPING (ABOVE GROUND) HOT WATER PIPING SANITARY SEWER (UNDER GROUND) SANITARY SEWER (ABOVE GROUND) SANITARY VENT STORM PIPING COPPER TYPE "K" COPPER TYPE "L" MAIN SERVICE VALVE COPPER TYPE "L" SCHEDULE 40 DWV PVC SCHEDULE 40 DWV PVC SCHEDULE 40 DWV PVC SCHEDULE 40 DWV PVC FINISHED GRADE PROVIDE A DEDUCT ALTERNATE TO USE PVC PIPING FOR SANITARY SEWER ABOVE GROUND. (MUST MEET LOCAL CODES) PLUMBING FIXTURES MUST MEET WATER SAVINGS STANDARDS AS REQUIRED BY ANSI, CITY CODE AND SPECIFICATIONS. FROM WATER MAIN MINIMUM PIPE SIZES TO FIXTURE TAIL PIECE: WATER CLOSET URINAL LAVATORY SINK KITCHEN SINK DISH WASHER FLOOR DRAIN MOP SINK 2" VENT, 4" WASTE, 1-1/4" COLD WATER 2" VENT, 4" WASTE, 1-1/4" COLD WATER 2" VENT, 2" WASTE, 3/4" HOT & COLD WATER 2" VENT, 2" WASTE, 3/4" HOT & COLD WATER 2" VENT, 2" WASTE, 3/4" HOT & COLD WATER WASTE TO K SINK, 3/4" HOT & COLD WATER 2" VENT, 3" WASTE 2" VENT, 3" WASTE, 3/4" HOT & COLD WATER NOT TO SCALE MINIMUM PIPE SIZE TO TAIL PIECE IS 3/4". GPM KW TYP T.P. UG COLD WATER DOMESTIC CW HOT WATER 110 DEG F HW HOT WATER RETURN HWR GALLON PER MINUTE KILOWATT SANITARY SEWER SANITARY VENT TYPICAL TRAP PRIMER WH UNDERGROUND VALVE WALL HYDRANT FS FD FLOOR SINK FLOOR DRAIN EXTERIOR WALL ZURN WALL HYDRANT FREEZE PROOF WITH VACUUM BREAKER NOT TO SCALE 3"VTR P 2 3"VTR ROOF P 1 ROOF 2" CW WITH VALVE. 3"V HOUSTON, TX 77XXX 2" CW 3"V 1/2" CW TO W.H. 1/2" CW TO W.H. SHEET: PLUMBING SCHEDULES & DETAILS FCO GCO 1ST FLOOR REVISIONS: 3"W 4" SS 4" SS 3"W 4" SS 4" SS WITH DOUBLE GROUND CLEAN OUT, REFERENCE CIVIL. NOT TO SCALE 11/21/14 PM: / PC: DATE: 09-24-14 PROJECT: CIVIL STRUCTURAL MEP TECHNOLOGY 1250 Wood Branch Park, Suite 210, HOUSTON TX 77079 office: 281-293-7500 www.dvoeng.com REGISTRATION NO. F-8334 SHEET: P.2