Rev. 14-02 CABLE INDEX Click to Return to Index Page Click Model Number to See Spec Coax Cables: TRI-RG59SIAM1000BK | 500BK.................................................................. RG59U + 18/2 Zipped Bulk Cable.............. 3 TRI-RG59SIAM1000WH | 500WH.............................................................. RG59U + 18/2 Zipped Bulk Cable.............. 4 TRI-RG59182BCSIAM500BK | 500WH............................RG59U + Two Bare Copper 18AWG Conductors.............. 5 TRI-RG6QUAD1MWHBX | 5WHBX...................................................................RG 6/U Coaxial Cable – White.............. 6 TRI-RG6U1MBK.....................................................................................................RG 6/U Coaxial Cable – Black.............. 7 TRI-RG6UCMR1MBK............................................................................................RG 6/U Coaxial Cable – Black.............. 8 Cat5E | Cat6A Cables: TRI-CAT5EBLUE | WHITE | YELLOW | GREY | GREEN..............................................................Cat5E Cable.........9-10 TRI-CAT5EDBRLBK......................................................................................................Cat5E Direct Burial Cable.......11-12 TRI-CAT6ABLUE | GN | GRAY | WH | YL.................23 AWG CAT6A CMR High-Performance Data Cable.......13-14 Multi Conductor Cables: TRI-142SLDFPLRFT41MBXRD........................................................................................14/2 Solid FPLR Cable............15 TRI-142SLDFPLR5CBXRD................................................................................................14/2 Solid FPLR Cable............16 TRI-142SLDFPLP1MRLRD...............................................................................................14/2 Solid FPLP Cable............17 TRI-162SLDFPLRFT45CBXRD | 41MBXRD...................................................................16/2 Solid FPLR Cable............18 TRI-162SLDFPLR1MRLRD...............................................................................................16/2 Solid FPLR Cable............19 TRI-164SLDFPLR5CBXRD................................................................................................16/4 Solid FPLR Cable............20 TRI-162STRBL | YL.......................................................................................................16/2 Stranded CM Cable............ 21. TRI-16265STRWH | PU | BL | YL.......................................................................16/2 Stranded CM/CL2 Cable............22 TRI-164STRBL................................................................................................................16/4 Stranded CM Cable............ 23. TRI-182SLDFPLRFT41MBXRD | 45CRLRD...................................................................18/2 Solid FPLR Cable............24 TRI-184SLDFPLRFT41MBXRD | 45CBXRD...................................................................18/4 Solid FPLR Cable............25 TRI-182STRFT41MBXGRY | 45CBXGRY....................................................................18/2 Stranded CM Cable............26 TRI-182STRFT41MBXWH | 45CBXWH......................................................................18/2 Stranded CM Cable............27 TRI-182STRCMPFT61MBXBEI.................................................................................18/2 Stranded CMP Cable............28 TRI-184STRFT45CBXGRY............................................................................................18/4 Stranded CM Cable............29 TRI-222SLD1MBXWH | 5CBGWH....................................................................................22/2 Solid CM Cable............30 TRI-222STR1MBXWH...................................................................................................22/2 Stranded CM Cable............31 TRI-222STR5CRLWH | BL | GRN | OR | YL.............................................................22/2 Stranded CM Cable............32 TRI-224SLD1MBXWH | 5CBXWH.....................................................................................22/4 Solid CM Cable............33 TRI-224SLD5CRLBG | BR | GN | GR | OR | YE..............................................................22/4 Solid CM Cable............34 TRI-224SLDFPLRFT41MBXRD | 45CRLRD...................................................................24/4 Solid FPLR Cable............35 TRI-224STR1MBXWH | 5CBXWH..............................................................................22/4 Stranded CM Cable............36 TRI-224STR5CRLWH | BR | BG | YL.........................................................................22/4 Stranded CM Cable............37 TRI-224STRCMPFT61MBXWH................................................................................22/4 Stranded CMP Cable............38 TRI-226STRSHLDFT4BXGRY...................................................................... 22/6 Stranded Shielded CM Cable............39 TRI-226STRSIG5CGRY........................................................................................22/6 Stranded CM / CL3 Cable............40 TRI-2212STR5CBXGRY............................................................................................22/12 Stranded CMP Cable............41 Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com COAX CABLES: RG59U+18/2 Zipped Bulk Cable Click to Return to Index Page TRI-RG59SIAM1000BK (1000’ Black) TRI-RG59SIAM500BK (500’ Black) PRODUCT FEATURES: DESCRIPTION: RG59U + 18/2 Zipped Bulk Cable CONSTRUCTION: This cable consists of a single RG59U cable and two 18 gauge conductors in a single jacket which can be easily separated. APPROVALS: UL / CM / CL2. APPLICATION: Designed for use with CCTV equipment. All wires are within one easy to separate PVC jacket. This single, easy to install cable eliminates the need for two separate power and video cables, saving you time during installation. CONSTRUCTION PARAMETERS: Conductor (Video) 20 AWG Bare Copper Conductor Insulation Material (Video) Gas Injected Foam Polyethylene Dielectric Shielding (Video) 95% Conductor (Power) 18 AWG Number of Conductors (Power) 2 Jacket Material (Video/Power) PVC Nominal Impedance 75 OHMs ELECTRICAL PROPERTIES: Nominal Attenuation Mhz ELECTRICAL Db/1000 ft 1Mhz PROPERTIES: 0.33 Velocity of Prop. Nominal Attenuation Mhz 10Mhz 0.88 50Mhz 100Mhz 200Mhz 400Mhz 700Mhz 900Mhz 1.85 2.51 3.58 5.29 7.45 8.7 1000Mhz 9.31 82% 16.19 Ohms/1000ft. Nominal 82%1000 ft JACKET: Overall Color VelocityJacket of Prop. Insulation Colors (Power) Black 82% Black and Red JACKET: Legend (Surface Ink Print): ***CCTV COMBO RG59/U CM BLACK 95% COPPER UL D-E311791 LOT # XXXXXXXX 1000FT Packaging TRI-RG59SIAM1000BK — Wooden Spool - In Box (1000’) TRI-RG59SIAM500BK — Pull Box (500’) TRI-RG59SIAM1000BK (37 lbs) TRI-RG59SIAM500BK (20 lbs) Weight Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com COAX CABLES: RG59U+18/2 Zipped Bulk Cable Click to Return to Index Page TRI-RG59SIAM1000WH (1000’ White) TRI-RG59SIAM500WH (500’ White) PRODUCT FEATURES: DESCRIPTION: RG59U + 18/2 Zipped Bulk Cable CONSTRUCTION: This cable consists of a single RG59U cable and two 18 gauge conductors in a single jacket which can be easily separated. APPROVALS: UL / CM / CL2. APPLICATION: Designed for use with CCTV equipment. All wires are within one easy to separate PVC jacket. This single, easy to install cable eliminates the need for two separate power and video cables, saving you time during installation. CONSTRUCTION PARAMETERS: Conductor (Video) 20 AWG Bare Copper Conductor Insulation Material (Video) Gas Injected Foam Polyethylene Dielectric Shielding (Video) 95% Conductor (Power) 18 AWG Number of Conductors (Power) 2 Jacket Material (Video/Power) PVC Nominal Impedance 75 OHMs ELECTRICAL PROPERTIES: Nominal Attenuation Mhz ELECTRICAL Db/1000 ft 1Mhz PROPERTIES: 0.33 10Mhz 0.88 50Mhz 100Mhz 200Mhz 400Mhz 700Mhz 900Mhz 1.85 2.51 3.58 Velocity of Prop. 5.29 7.45 8.7 1000Mhz 9.31 82% JACKET: Overall Jacket Color White Insulation Colors (Power) Black and Red Legend (Surface Ink Print): ***CCTV COMBO RG59/U CM WHITE 95% COPPER UL D-E311791 LOT # XXXXXXXX 1000FT Packaging TRI-RG59SIAM1000WH — Wooden Spool - In Box (1000’) TRI-RG59SIAM500WH — Pull Box (500’) TRI-RG59SIAM1000WH (37 lbs) TRI-RG59SIAM500WH (20 lbs) Weight Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com COAX CABLES: RG59U Coaxial Cable + Two Bare Copper 18AWG Conductors Click to Return to Index Page TRI-RG59182BCSIAM500BK (500’ Black) TRI-RG59182BCSIAM500WH (500’ White) PRODUCT FEATURES: DESCRIPTION: RG59U Coaxial Cable + Two Bare Copper 18AWG Conductors CONSTRUCTION: This cable consists of a single RG59U cable and two 18 gauge conductors in a single jacket which can be easily separated APPROVALS: NEC Article 725 and 820. APPLICATION: Designed for use with CCTV equipment. All wires are within one easy to separate PVC jacket. This single, easy to install cable eliminates the need for two separate power and video cables, saving you time during installation. . CONSTRUCTION PARAMETERS: Conductor RG59: 20 AWG(1/0.032”) BC 2×, 18AWG Conductor: 7/26 BareCopper Dielectric RG59: Foam PE 18AWG Conductor: PVC Nom. Dielectric Wall Thickness RG59: 0.057” 18AWG Conductor: 0.010” Nom. Dielectric Diameter RG59: 0.146” 18AWG Conductor: 0.068” Shield / Nom. Shield Diameter 95% CCA Braid / 0.174 Jacket Material / Jacket Thickness PVC / 0.034” Nom. Overall Cable Diameter 0.236” * 0.493” Flame Rating UL1581 Vertical Tray Flame Test ELECTRICAL PROPERTIES (RG 59): Frequency (Mhz) 50 100 200 400 700 1000 Max. Attentuation (dB/1000 ft) @ 20ºC 1.9 2.5 3.6 5.0 6.9 8.5 Impedence (Ohms) Velocity of Propagation (%) DC Resistance (Ω/mft.) @ 20ºC Nom. Capacitance 75 ± 3 78 10.2 16.3 pF/ft. JACKET: Overall Jacket Color / Insulation Colors (Power) BK = Black or WH = White / Black and Red Legend (Surface Ink Print): Jacket is sequentially foot marked CCTV RG59 20AWG SOL BC95% CCA BRD+18/2 CM UL C (UL) E354460 75C ROHS COMPLIANT DC 0413 ZONE 0 1 2 3 4 5 6 7 8 9 Packaging / Weight Pull Box (500’) / 23 lbs Max. Temperature Rating 60ºC Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com COAX CABLES: RG 6/U COAXIAL CABLE – White Click to Return to Index Page TRI-RG6QUAD5WHBX (500’ White) TRI-RG6QUAD1MWHBX (1000’ White) PRODUCT FEATURES: DESCRIPTION: RG 6/U COAXIAL CABLE WITH TWO FOILS PLUS 40% AND 60% ALUMINUM BRAID APPROVALS: NEC Article 725 and 820 CONSTRUCTION PARAMETERS: Conductor 18 AWG (1/0.040”) solid CCS Dielectric Foam PE Nominal Dielectric Wall Thickness 0.070” Nominal Dielectric Diameter 0.180” Shielding 1 & 2 Bonded Polyester/Aluminum Tape and 60% Aluminum Braid Shielding 3 & 4 Polyester/Aluminum Tape and 40% Aluminum Braid Nominal Overall Shield Diameter 0.249” Jacket Material PVC Jacket Thickness 0.032” Nominal Overall Cable Diameter 0.300” Approximate Cable Weight (lbs./1000ft) 26 Flame Rating UL1581 Vertical Tray Flame Test Max Temperature Rating 75° C ELECTRICAL PROPERTIES: Detailed Electrical Properties Available Frequency 55 250 300 350 MHz Max Attenuation (dB/100m) @ 20°C 1.6 3.36 3.7 4.01 450 500 750 4.58 4.84 6 Please See Chart on Page 2 1000 1200 1400 1500 1700 1900 7 7.5 8.1 8.4 8.9 9.6 2000 9.8 Impedance (Ohms) Min. Velocity of Propagation (%) DC Resistance (Ω/mft.) @ 20°C Nominal Capacitance 75±3 78 33 16.2pF/ft. JACKET: Jacket Colors White Legend (Surface Ink Print): ***FT RG6/U 18 AWG QUAD SHIELD DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com COAX CABLES: RG6/U COAXIAL CABLE – Black Click to Return to Index Page TRI-RG6U1MBK (1000’) PRODUCT FEATURES: DESCRIPTION: RG-6/U 60% CM CATV 75 Ω Coaxial Cable CONSTRUCTION: This cable consists of an 18 AWG solid copper clad steel conductor (CCS). Foamed polyethylene insulation; 60% Coverage Aluminum Wire Braid shield, PVC jacket. STANDARDS: Ref. SCTE IPS-SP-001 — UL 1655, UL 13, UL 444, ROHS Compliant APPLICATION: Designed for use with CCTV equipment. PHYSICAL CHARACTERISTICS: Conductor Solid 18 AWG Copper Clad Steel, 0.04” dia. Insulation Material Foamed Polyethylene, Nom Thickness 0.073”, Dia. 0.186” Braid Shield Aluminum Wire 60% Coverage Area, 0.213” Braid Dia. Jacket PVC, 0.2716” Cable Dia., Nom. Thickness 0.0295 ELECTRICAL CHARACTERISTICS: Temperature Rating -20˚ ~ 60˚ C Impedance 75 Ohms (±3.0 Ohms) Capacitance 15.5 (pF/ft) Conductor DCR@20˚ C 28.6 (Ohms/1000ft) Velocity of Propagation 84% ELECTRICAL PERFORMANCE: Frequency 5 Mhz 55 Mhz 211 Mhz 250 Mhz 270 Mhz 300 Mhz 350 Mhz 400 Mhz 450 Mhz 500 Mhz Nom. Attentuation (Db/100 ft) 2.66 5.25 10.10 11.02 11.48 12.14 13.15 14.11 15.03 15.88 Frequency 550 Mhz 600 Mhz 750 Mhz 870 Mhz 1000 Mhz 1250 Mhz 1450 Mhz 2200 Mhz 2400 Mhz 3000 Mhz 16.70 17.52 19.69 21.33 22.97 25.00 26.37 31.16 32.83 37.88 Nom. Attentuation (Db/100 ft) JACKET: Jacket / Insulation Colors Black / White Legend (Surface Ink Print): RG6/U 18AWG CMR XXXXXXX VERIFIED TO C(ETL)US CATV SWEPT TO 3.0 GHZ XXXXFT Packaging / Weight Pull Box / 29 Lbs Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com COAX CABLES: RG6/U COAXIAL CABLE – Black Click to Return to Index Page TRI-RG6UCMR1MBK (1000’) PRODUCT FEATURES: DESCRIPTION: RG6U Bulk CoaxialCable CONSTRUCTION: This cable consists of an 18 AWG solid copper covered steel conductor (CCS). foamed LDPE insulation; overall 100% poly/alum foil tape; overall 65% aluminum braid; overall black sunlight resistant PVC jacket. APPROVALS: Type CL2 / NEC Article 725 / UL 1581 APPLICATION: Designed for use with CCTV equipment. CONSTRUCTION PARAMETERS: Conductor solid 18 AWG copper covered steel, Outer Dia. 0.180” Insulation Material Foamed LDPE, Nominal Wall Thickness 0.070”, white Shielding Jacket 100% Coverage Bonded Poly/Alum tape — 65% Coverage Aluminum braid Sunlight Resistant PVC,0.032” Nominal Thickness, Outer Dia. 0.254” ELECTRICAL PROPERTIES: Maximum Attenuation (Mhz) Db/100 ft 50Mhz 100Mhz 200Mhz 400Mhz 700Mhz 1000Mhz 1.46 2.05 2.83 4.15 5.60 6.70 Velocity of Prop. 84% Temperature -20° C ~ 75° C Voltage 300 Volt Capacitance 16.2 pF/ft. Nom. Impedance 75 Ohms/M’ DC Resistance 7.5 Ohms/M’ @ 20° C JACKET: Overall Jacket Color Black Insulation Colors White Legend (Surface Ink Print): UPG SR6FA RG6/U 18 AWG (UL) TYPE CMR SUNLIGHT RESISTANT UL Standard 13 Packaging Pull Box Weight 30 Lbs. Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com Cat5E CABLES: Cat 5E 350MHz UTP PVC Cable TRI-CAT5EBLUE (1000’) TRI-CAT5EYELLOW (1000’) TRI-CAT5EGREEN (1000’) [Page 1 of 2] Click to Return to Index Page TRI-CAT5EWHITE (1000’) TRI-CAT5EGREY (1000’) GENERAL SPECIFICATIONS: Cable Type SPECIFICATION: Conductor Material Solid Bare Copper Jacket Material Conductor Gauge, singles 24 AWG Conductor Type, singles Solid 8 Compliant MECHANICAL CHARACTERISTICS: 0.483 mm | 0.019 in Insulation Blue|White|Yellow|Grey|Green ISO 9001:2008 5.0 mm | 0.197 in Conductor Dia. 4 Jacket Colors RoHS 2002/95/EC 305 m | 1000 ft Diameter Over Jacket (±0.2mm) Pairs, quantity Conductors, quantity PVC Cable Length U/UTP (unshielded) Polyethylene (PE) Test Object Jacket Average Thickness(±0.03mm) 0.21 mm | 0.008 in Test Material Min. Point Thickness 0.2 mm | 0.007 in Before Tensile Strength (Mpa) Insulation Dia.(±0.03mm) 0.9 mm | 0.035 in Aging Elongation (%) >=100 Twisting Lay Length 30 mm | 1.181 in Aging Condition ( xhrs) 100x240 Cabling Lay Length(±20mm) (±20mm) 100 mm | 3.937 in Min. Point Thickness 0.43 mm | 0.016 in Rip Cord PVC >=13.8 After Tensile Strength (Mpa) >=85% of unaged Aging Elongation (%) >=50% of unaged Cold Bend(-20±2 x4hrs) YES No crack ELECTRICAL SPECIFICATION: ANSI/TIA Category 5E Transmission Standards ANSI/TIA-568-C.2 | ISO/IEC 11801 Class D Reference Standard YD/T1019-2001, UL Subject 444 Product Standard Certification UL File E222804 1.0-100.0MHz Impedance (ohms) 100 ± 15 100-200MHz Impedance (ohms) 100 ± 25 200-350MHz Impedance (ohms) 100 ± 35 1.0-100.0MHz Delay Skew (ns/100m) <=45 Pair-to-Ground Capacitance Unbalance (pF/100m) <=330 Max. Conductor DC Resistance 20 (ohms/km) 93.8 Resistance Unbalance (%) <=5 Installation Temperature 0 °C to +60 °C (+32 °F to +140 °F) Operating Temperature -20 °C to +60 °C (-4 °F to +140 °F) Detailed Electrical Characteristics Continued Connectivity Please See Chart on Page 2 • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com Cat5E CABLES: Cat 5E 350MHz UTP PVC Cable TRI-CAT5EBLUE (1000’) TRI-CAT5EYELLOW (1000’) TRI-CAT5EGREEN (1000’) [Page 2 of 2] Click to Return to Index Page TRI-CAT5EWHITE (1000’) TRI-CAT5EGREY (1000’) ELECTRICAL PROPERTIES: Frequency Return Loss Attentuation NEXT ACR PSNEXT (MHz) (dB) (dB/100m) (dB) (dB) (dB) 0.772 19.4 1.8 67 65 64 66 63 575 1 20 2 65.3 63 62.3 63.8 60.8 570 4 23 4.1 56.3 52 53.3 51.7 48.7 552 8 24.5 5.8 51.8 46 48.8 45.7 42.7 546.7 10 25 6.5 50.3 44 47.3 43.8 40.8 545.4 16 25 8.2 47.3 39 44.3 39.7 36.7 543 20 25 9.3 45.8 37 42.8 37.7 34.7 542 25 24.3 10.4 44.3 34 41.3 35.8 32.8 541.2 31.25 23.6 11.7 42.9 31 39.9 33.9 30.9 540.4 62.5 21.5 17 38.4 21 35.4 27.8 24.8 538.6 100 20.1 22 35.3 13 32.3 23.8 20.8 537.6 250 17.6 36.8 29.3 -12.3 26.3 15.8 12.8 494.2 350 16.3 44.8 27.1 -18.5 24.1 12.9 9.9 472.4 Connectivity • Security • ELFEXT PSELFEXT Delay (dB/100m) (dB/100m) (ns/100m) Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com Cat5E CABLES: 24 AWG / 4 PAIRS RISER CATEGORY 5e PLUS UTP DATA CABLE [Page 1 of 2] Click to Return to Index Page TRI-CAT5EDBRLBK PRODUCT FEATURES: DESCRIPTION: 24 AWG / 4 PAIRS RISER CATEGORY 5e PLUS UTP DATA CABLE RATING: UL LISTED CMR APPROVALS: NEC Article 800, ANSI/TIA/EIA-568-B.2 Category 5e and UL Verified to Category 5e APPLICATION: Direct Burial, designed for use with CCTV equipment. CONSTRUCTION PARAMETERS: Conductor 24 AWG solid bare copper Insulation Material PE Nominal Insulation Thickness 0.008” Insulated Conductor Diameter 0.036” Pair Lays Each pair has different lay length for cross-talk prevention Jacket Material PVC Jacket Thickness 0.020” Nominal Overall Cable Diameter 0.220” Approximate Cable Weight (lbs./1000ft) 22 Flame Rating UL 1666 riser ELECTRICAL PROPERTIES: Impedance(Ohms) 1~100MHZ 100±15 100~200MHz 200~350MHz 100±22 100±32 Delay Skew Velocity of Max. Cap. Max. Cap. (ns/100m) Propagation DC Resistance DC Resistance (Ω/100m) Unbalance (%) @1000Hz Unbalance 20 70(%) 9.2 @ 20°C 3 15 pF/ft. 300 pF/100m Detailed Electrical Properties Continued Please See Chart on Page 2 JACKET: Insulation Colors Blue/White with Blue, Orange/White with Orange, Green/White with Green, Brown/White with Brown Jacket Color BLK = Black Legend (Surface Ink Print): ***FT E164061 VERIFIED (UL) CAT 5e Plus 24AWG TYPE CMR TO TIA/EIA-568-B.2 UTP DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Reel Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com Cat5E CABLES: 24 AWG / 4 PAIRS RISER CATEGORY 5e PLUS UTP DATA CABLE Click to Return to Index Page [Page 2 of 2] TRI-CAT5EDBRLBK ELECTRICAL PROPERTIES: Frequency MHz Max Attenuation (dB/100m) @ 20°C Min NEXT (dB/100m) Min ELFEXT (dB/100m) Min PS-ELFEXT (dB/100m) 1 1.9 68.3 66.3 20 64 61 4 3.8 59.3 57.3 23 52 49 8 5.5 54.8 52.8 24.5 46 43 10 6.1 53.3 51.3 25 44 41 16 7.8 50.3 48.3 25 40 37 20 8.8 48.8 46.8 25 38 35 25 9.9 47.3 45.3 24.3 36 33 31.25 11.1 45.9 43.9 23.6 34 31 62.5 16.1 41.4 39.4 21.5 28 25 100 20.9 38.3 36.3 20.1 24 21 155 26.7 35.5 33.5 18.8 20 17 200 30.8 29.8 27.8 18 12 11 250 35 28.3 26.3 17.3 10 9 300 38.9 27.2 25.2 16.8 8.2 7.2 350 42.6 26.2 24.2 16.3 7 6 Connectivity Min PS-NEXT Min Return (dB/100m) Loss (dB/100m) • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com Cat6A CABLES: 23 AWG CAT6A CMR HIGH-PERFORMANCE DATA CABLE TRI-CAT6ABLUE (1000’–Blue) TRI-CAT6AYL (1000’–Yellow) TRI-CAT6AGN (1000’–Green) Click to Return to Index Page [Page 1 of 2] TRI-CAT6AWH (1000’–White) TRI-CAT6AGRAY (1000’–Grey) Outer Aerated Jacket 23 AWG Conductor T-Top Separator Insulation SPECIFICATION: Number of Conductor Pairs 4 Size 23 AWG Stranding DESCRIPTION / STANDARDS: Solid Conductor Material Solid Annealed Bare Copper • 23 AWG CAT6A CMR, High-Performance Data Cable Shield Material • ETL Listed Type CMR Rip Cord • C(ETL) listed CMG FT4 Insulation Material • TIA - 568-C.2, and ISO/IEC 11801 Insulation Overall Diameter • ROHS Compliant Insulation Average Thickness • ATM 155 Mbps Jacket • Ethernet 10BASE-T, 100BASE-TX, 100BASE-VG, 100BASE-T4, Outer Jacket Avg Wall Thickness • 1000 Mbps 1000BASE-T Gigabit Ethernet™ (IEEE 802.3) Outer Jacket Nominal O.D. • 16 Mbps Token Ring™ (IEEE 802.5) Nominal Weight MECHANICAL CHARACTERISTICS: COLOR CODE / CABLE MARKING: Temperature Rating (Installation) 0 to + 60°C Pair 1 White / Blue Blue Temperature Rating (Operating) -20°C to + 75°C Pair 2 White / Orange Orange Tensile Strength (Before Aging) > = 13.8 Mpa Pair 3 White / Green Green > = 100% Pair 4 White / Brown Brown Elongation (Before Aging) Aging Condition 100°C x 168 hours Tensile Strength (After Aging) > = 85% of unaged Elongation (After Aging) > = 50% of unaged Unshielded Yes HDPE 0.04 in. ± 0.0002 in. 0.0086 in. Flame Retardant PVC 0.022 in. 0.3 in. ± 0.008 in. 55 lbs. Legend (Surface Ink Print): E223070 23AWG 4PR UTP CMR 75C C(UL)US VERIFIED (UL) CATEGORY 6A ANSI/TIA-568-C.2 XXXXFT ELECTRICAL SPECIFICATION: Maximum Conductor DC Resistance @ 20°C 6.85 Ω / 100 Meters Maximum DC Resistance Unbalanced @ 20°C 5% Maximum Pair-to-Pair Ground Capacitance Unbalanced 330 pF / 100 Meters Characteristic Impedance 100 ± 15 Ω Mutual Capacitance 5.6 nF / 100 Meters Maximum Delay Skew 40 nS / 100 Meters Detailed Electrical Characteristics Continued Connectivity Please See Chart on Page 2 • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com Cat6A CABLES: 23 AWG CAT6A CMR HIGH-PERFORMANCE DATA CABLE TRI-CAT6ABLUE (1000’–Blue) TRI-CAT6AYL (1000’–Yellow) TRI-CAT6AGN (1000’–Green) Click to Return to Index Page [Page 2 of 2] TRI-CAT6AWH (1000’–White) TRI-CAT6AGRAY (1000’–Grey) Outer Aerated Jacket 23 AWG Conductor T-Top Separator Insulation ELECTRICAL PROPERTIES: Frequency Attentuation Return Loss NEXT PS-NEXT ELFEXT PS-ELFEXT Delay (MHz) Max. (dB/100m) Min. (dB) Min. (dB) Min. (dB) Min. (dB) Min. (dB) Min. (dB) 1 1.9 20 74.3 72.3 67.8 64.8 570 4 3.78 23.01 65.24 63.27 55.76 52.76 552 10 5.95 25 59.3 57.3 47.8 44.8 545 16 7.55 25 56.24 54.24 43.72 40.72 543 20 8.47 25 54.78 52.78 41.78 38.78 542 21.25 10.67 23.64 51.88 49.88 37.9 34.9 540 62.5 15.38 21.54 47.36 45.36 31.88 28.8 538 100 19.8 20.11 44.3 42.3 27.8 24.8 537 200 28.98 18 39.78 37.78 21.78 18.78 536 250 32.85 17.32 38.33 36.33 19.84 16.84 536 400 42.96 15.89 35.2 33.2 15.9 12.9 535 500 48.92 15.21 33.8 31.8 14.02 11.02 535 Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 14/2 Solid FPLR Cable – Red Click to Return to Index Page TRI-142SLDFPLRFT41MBXRD (1000’) PRODUCT FEATURES: DESCRIPTION: 14/2 Solid FPLR Cable. CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and NEC Article 760. APPLICATION: Power Limited Fire Alarm Circuit Cable for Riser Applications. CONSTRUCTION PARAMETERS: Conductor 14 AWG Bare Copper Stranding Solid Insulation Material PVC Nominal Insulation Thickness 0.015” Insulated Conductor Diameter 0.090” Number of Conductors 2 Nominal Lay Length 5.5” Jacket Material PVC Jacket Thickness 0.020” Nominal Overall Cable Diameter 0.230” Approximate Cable Weight (lbs./1000ft.) 40 Flame Rating UL 1666 Riser Flame Test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 2.52 Ohms/1000ft. nominal Capacitance Between Conductors @ 1 KHz 42 pF/ft. nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black and Red Jacket Colors Red Legend (Surface Ink Print): ***FT E164182 (UL) 14AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 14/2 Solid FPLR Cable – Red Click to Return to Index Page TRI-142SLDFPLR5CBXRD (500’) PRODUCT FEATURES: DESCRIPTION: 14/2 Solid FPLR Cable. CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and NEC Article 760. APPLICATION: Power Limited Fire Alarm Circuit Cable for Riser Applications. CONSTRUCTION PARAMETERS: Conductor 14 AWG Bare Copper Stranding Solid Insulation Material PVC Nominal Insulation Thickness 0.015” Insulated Conductor Diameter 0.090” Number of Conductors 2 Nominal Lay Length 5.5” Jacket Material PVC Jacket Thickness 0.020” Nominal Overall Cable Diameter 0.230” Approximate Cable Weight (lbs./1000ft.) 40 Flame Rating UL 1666 Riser Flame Test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 2.52 Ohms/1000ft. nominal Capacitance Between Conductors @ 1 KHz 42 pF/ft. nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black and Red Jacket Colors Red Legend (Surface Ink Print): ***FT E164182 (UL) 14AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 14/2 Solid FPLP Cable – Red Click to Return to Index Page TRI-142SLDFPLP1MRLRD (1000’) PRODUCT FEATURES: DESCRIPTION: 14/2 Solid FPLP Cable CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and NEC Article 760. APPLICATION: Power Limited Fire Alarm Circuit Cable Used in Plenum Applications.. CONSTRUCTION PARAMETERS: Conductor 14 AWG bare copper Stranding Solid Insulation Material Low Smoke PVC Nominal Insulation Thickness 0.013” Insulated Conductor Diameter 0.090” Number of Conductors 2 Nominal Lay Length 5.0” Jacket Material Low Smoke PVC Jacket Thickness 0.015” Nominal Overall Cable Diameter 0.210” Approximate Cable Weight (lbs./1000ft) 37 Flame Rating UL 910 Steiner Tunnel Smoke and Flame Test ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 2.52 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 42 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Red and Black Jacket Colors Red Legend (Surface Ink Print): ***FT E164061 (UL) 14AWG TYPE FPLP DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Reel Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 16/2 Solid FPLR Cable – Red Click to Return to Index Page TRI-162SLDFPLRFT45CBXRD (500’) TRI-162SLDFPLRFT41MBXRD (1000’) PRODUCT FEATURES: DESCRIPTION: 16/2 Solid FPLR Cable CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable. CONSTRUCTION PARAMETERS: Conductor 16 AWG bare copper Stranding Solid Insulation Material PVC Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.070” Number of Conductors 2 Nominal Lay Length 5.0” Jacket Material PVC Jacket Thickness 0.025” Nominal Overall Cable Diameter 0.190” Approximate Cable Weight (lbs./1000ft.) 30 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 4.02 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 40 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black, Red Jacket Colors Red Legend (Surface Ink Print): ***FT E164182 (UL) 16AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 16/2 Solid FPLR Cable – Red Click to Return to Index Page TRI-162SLDFPLR1MRLRD (1000’) PRODUCT FEATURES: DESCRIPTION: 16/2 Solid FPLR Cable CONSTRUCTION: This cable consists of 2 conductors 16 AWG solid bare copper; color-coded PVC insulation; overall red PVC jacket. APPROVALS: Type FPLR; UL Standard 1424; NEC Article 760; UL 1581. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable. CONSTRUCTION PARAMETERS: Conductor 16 AWG solid bare copper Insulation Material PVC Nominal Insulation Thickness 0.011” Number of Conductors 2 Jacket Material PVC Jacket Thickness 0.020” Nominal Overall Cable Diameter 0.186” Approximate Cable Weight (lbs./1000ft.) 23 Lbs. Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: DC Resistance 4.2 Ohms/M’ @ 20° C Capacitance Between Conductors 40.6 pF/ft. Nominal @ 1 MHz Impedance 54 Ohms Velocity of Propagation 46.6% Operating Voltage 300 Volt Temperature Rating -20° to 75° C JACKET: Insulation Colors Black, Red Jacket Colors Legend (Surface Ink Print): Red 16/2C SOL FIRE FPLR (****) 75° c XXXXXX (***) ROHS COMPLIANT (**) (*) Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 16/4 Solid FPLR Cable – Red Click to Return to Index Page TRI-164SLDFPLR5CBXRD (500’) PRODUCT FEATURES: DESCRIPTION: 16/4 Solid FPLR Cable CONSTRUCTION: This cable consists of four bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable. CONSTRUCTION PARAMETERS: Conductor 16 AWG bare copper Stranding Solid Insulation Material PVC Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.070” Number of Conductors 4 Nominal Lay Length 6.0” Jacket Material PVC Jacket Thickness 0.020” Nominal Overall Cable Diameter 0.225” Approximate Cable Weight (lbs./1000ft) 55 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 4.02 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 40 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black, Red, Blue and Yellow Jacket Colors Red Legend (Surface Ink Print): ***FT E164182 (UL) 16AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 16/2 Stranded CM – Black or Yellow Click to Return to Index Page TRI-162STRBL (500’ Black) TRI-162STRYL (500’ Yellow) PRODUCT FEATURES: DESCRIPTION: 16/2 Stranded CM CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall core wrap. The overall assembly has an overall extruded jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: General Purpose Power Limited Circuit Cable and Communications Cable Used in Audio Applications. CONSTRUCTION PARAMETERS: Conductor 16 AWG bare copper Stranding 26/30 Insulation Material FR-PVC Nominal Insulation Thickness 0.012” Insulated Conductor Diameter 0.080” Number of Conductors 2 Nominal Lay Length 2.4” Jacket Material Extra Flexible FR-PVC Core Wrap Nonwoven Jacket Thickness 0.026” Nominal Overall Cable Diameter 0.212” Approximate Cable Weight (lbs./1000ft) 29 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 4.02 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 30 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black and Red Jacket Colors BL = Black / YL = Yellow Legend (Surface Ink Print): ***FT OXYGEN FREE COPPER E164061 (UL) 16AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 16/2 Stranded CM/CL2 – 500ft – White TRI-16265STRWH(White) TRI-16265STRBL (Blue) Click to Return to Index Page TRI-16265STRPU(Purple) TRI-16265STRYL(Yellow) PRODUCT FEATURES: DESCRIPTION: 16/2 Stranded CM/CL2 Cable CONSTRUCTION: This cable consists of two Oxygen Free bare copper insulated conductors and an overall core wrap. The overall assembly has an overall extruded jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: General Purpose Power Limited Circuit Cable and Communications Cable used in Audio Applications. CONSTRUCTION PARAMETERS: Conductor 16 AWG Oxygen Free bare copper Stranding 65/34 Insulation Material FR-PVC Nominal Insulation Thickness 0.012” Insulated Conductor Diameter 0.080” Number of Conductors 2 Nominal Lay Length 2.4” Jacket Material Extra Flexible FR-PVC Core Wrap Nonwoven Jacket Thickness 0.026” Nominal Overall Cable Diameter 0.212” Approximate Cable Weight (lbs./1000ft.) 29 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 4.02 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 30 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black and Red Jacket Colors WH=White, PU=Purple, BL=Blue, YL=Yellow Legend (Surface Ink Print): UPG 1602 16/2 (65/34) OFC HI-FLEX AUDIO CM UL (C) UL E35460 75C ROHS COMPLIANT DC 0513 ZONE 1 2 3 4 5 6 7 8 9 Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 16/4 STRANDED CM CABLE – Blue Click to Return to Index Page TRI-164STRBL (500’) PRODUCT FEATURES: DESCRIPTION: 16/4 Stranded CM Cable CONSTRUCTION: This cable consists of four bare copper insulated conductors and an overall core wrap. The overall assembly has an overall extruded jacket.. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: General Purpose Power Limited Circuit Cable and Communications Cable Used in Audio Applications. CONSTRUCTION PARAMETERS: Conductor 16 AWG bare copper Stranding 26/30 Insulation Material FR-PVC Nominal Insulation Thickness 0.012” Insulated Conductor Diameter 0.080” Number of Conductors 4 Nominal Lay Length 5.1” Jacket Material Extra Flexible FR-PVC Core Wrap Nonwoven Jacket Thickness 0.023” Nominal Overall Cable Diameter 0.24” Approximate Cable Weight (lbs./1000ft) 50 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 4.02 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 30 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black, Red, White and Green Jacket Colors Blue Legend (Surface Ink Print): ***FT OXYGEN FREE COPPER E164061 (UL) 16AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 18/2 Solid FPL Cable – Red Click to Return to Index Page TRI-182SLDFPLRFT45CRLRD (500’) TRI-182SLDFPLRFT41MBXRD (1000’) PRODUCT FEATURES: DESCRIPTION: 18/2 Solid FPL Cable CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications. CONSTRUCTION PARAMETERS: Conductor 18 AWG bare copper Stranding Solid Insulation Material PVC Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.060” Number of Conductors 2 Nominal Lay Length 4.5” Jacket Material PVC Jacket Thickness 0.020” Nominal Overall Cable Diameter 0.170” Approximate Cable Weight (lbs./1000ft) 20 Flame Rating UL 1666 riser flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 6.43 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 35 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Red and Black Jacket Colors Red Legend (Surface Ink Print): ***FT E164182 (UL) 18AWG TYPE FPL DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 18/4 Solid FPLR Cable – Red Click to Return to Index Page TRI-184SLDFPLRFT45CBXRD (500’) TRI-184SLDFPLRFT41MBXRD (1000’) PRODUCT FEATURES: DESCRIPTION: 18/4 Solid FPLR Cable CONSTRUCTION: This cable consists of four bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and NEC Article 760. APPLICATION: Fire Alarm Power Limited Circuit Cable for Addressable Fire Alarm Systems. CONSTRUCTION PARAMETERS: Conductor 18 AWG bare copper Stranding Solid Insulation Material PVC Nominal Insulation Thickness 0.015” Insulated Conductor Diameter 0.070” Number of Conductors 4 Nominal Lay Length 5.0” Jacket Material PVC Jacket Thickness 0.020” Nominal Overall Cable Diameter 0.230” Approximate Cable Weight (lbs./1000ft) 40 Flame Rating UL 1666 riser flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 6.43 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 27 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black, Red, Yellow and Blue Jacket Colors Red Legend (Surface Ink Print): ***FT E164182 (UL) 18AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 18/2 Stranded CM – Gray Click to Return to Index Page TRI-182STRFT45CBXGRY (500’) TRI-182STRFT41MBXGRY (1000’) PRODUCT FEATURES: DESCRIPTION: 18/2 Stranded CM CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 13 and UL 444, NEC Articles 725 and 800. APPLICATION: Class 3 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 18 AWG bare copper Stranding 7/26 Insulation Material PVC Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.066” Number of Conductors 2 Nominal Lay Length Parallel Jacket Material PVC Jacket Thickness 0.018” Nominal Overall Cable Diameter 0.170” Approximate Cable Weight (lbs./1000ft.) 19 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 6.43 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 32 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black, Red Jacket Colors Legend (Surface Ink Print): Gray ***FT E164061 (UL) 18AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 18/2 Stranded CM – White Click to Return to Index Page TRI-182STRFT45CBXWH (500’) TRI-182STRFT41MBXWH (1000’) PRODUCT FEATURES: DESCRIPTION: 18/2 Stranded CM CONSTRUCTION: This cable consists of two bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and UL 444, NEC Articles 725 and 800. APPLICATION: Class 3 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 18 AWG bare copper Stranding 7/26 Insulation Material PVC Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.066” Number of Conductors 2 Nominal Lay Length Parallel Jacket Material PVC Jacket Thickness 0.018” Nominal Overall Cable Diameter 0.170” Approximate Cable Weight (lbs./1000ft.) 19 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 6.43 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 32 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black and Red Jacket Colors White Legend (Surface Ink Print): ***FT E164061 (UL) 18AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 18/2 Stranded CMP – Beige Click to Return to Index Page TRI-182STRCMPFT61MBXBEI (1000’) PRODUCT FEATURES: DESCRIPTION: 18/2 Stranded CMP CONSTRUCTION: This cable consists of two bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: Class 2 General Purpose Power Limited Circuit Cable and Communication Cable for Plenum Applications. CONSTRUCTION PARAMETERS: Conductor 18 AWG bare copper Stranding 7/26 Insulation Material Low Smoke PVC Nominal Insulation Thickness 0.008” Insulated Conductor Diameter 0.065” Number of Conductors 2 Nominal Lay Length 4.5” Jacket Material Low Smoke PVC Jacket Thickness 0.015” Nominal Overall Cable Diameter 0.165” Approximate Cable Weight (lbs./1000ft) 25 Flame Rating UL 910 Steiner Tunnel Smoke and Flame Test ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 6.43 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 33 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black, Red Jacket Colors Beige Legend (Surface Ink Print): ***FT E164061 (UL) 18AWG TYPE CMP DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 18/4 Stranded CM – Gray Click to Return to Index Page TRI-184STRFT45CBXGRY (500’ Gray) PRODUCT FEATURES: DESCRIPTION: 18/4 Stranded CM CONSTRUCTION: This cable consists of four bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: Class 3 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 18 AWG bare copper Stranding 7/26 Insulation Material PVC Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.068” Number of Conductors 4 Nominal Lay Length 5.0” Jacket Material PVC Jacket Thickness 0.020” Nominal Overall Cable Diameter 0.205” Approximate Cable Weight (lbs./1000ft) 33 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 6.43 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 35 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black, Red, White and Green Jacket Colors Gray Legend (Surface Ink Print): ***FT E164061 (UL) 18AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/2 Solid CM – White Click to Return to Index Page TRI-222SLD1MBXWH (1000’ White-Box) TRI-222SLD5CBGWH (500’ White-Bag) PRODUCT FEATURES: DESCRIPTION: 22/2 Solid CM CONSTRUCTION: This cable consists of two bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and UL 444, NEC Articles 725 and 800. APPLICATION: Class 2 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 22 AWG bare copper Stranding Solid Insulation Material PE Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.038” Number of Conductors 2 Nominal Lay Length Parallel Jacket Material PVC Jacket Thickness 0.015” Nominal Overall Cable Diameter 0.105” Approximate Cable Weight (lbs./1000ft) 9 Flame Rating UL 1581 vertical tray flame test ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 30 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black and Red Jacket Colors White Legend (Surface Ink Print): ***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging TRI-222SLD1MBXWH (Box) / TRI-222SLD5CBGWH (Bag) Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/2 Stranded CM – 1000ft Click to Return to Index Page TRI-222STR1MBXWH (1,000’) PRODUCT FEATURES: DESCRIPTION: 22/2 Stranded CM CONSTRUCTION: This cable consists of two bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and UL 444, NEC Articles 725 and 800. APPLICATION: Class 2 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 22 AWG bare copper Stranding 7/30 Insulation Material PE Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.046” Number of Conductors 2 Nominal Lay Length Parallel Jacket Material PVC Jacket Thickness 0.015” Nominal Overall Cable Diameter 0.120” Approximate Cable Weight (lbs./1000ft.) 9 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 32 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black and Red. Jacket Colors WH = White Legend (Surface Ink Print): ***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/2 Stranded CM – 500ft Click to Return to Index Page TRI-222STR5CRLWH(White) TRI-222STR5CRLBL(Black) TRI-222STR5CRLGRN(Green) TRI-222STR5CRLOR(Orange) TRI-222STR5CRLYL(Yellow) PRODUCT FEATURES: DESCRIPTION: 18/2 Stranded CM CONSTRUCTION: This cable consists of two bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and UL 444, NEC Articles 725 and 800. APPLICATION: Class 2 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 22 AWG bare copper Stranding 7/30 Insulation Material PE Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.046” Number of Conductors 2 Nominal Lay Length Parallel Jacket Material PVC Jacket Thickness 0.015” Nominal Overall Cable Diameter 0.120” Approximate Cable Weight (lbs./1000ft.) 9 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 32 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Jacket Colors Black and Red. WH = White / BL = Black / GRN = Green / OR = Orange / YL = Yellow Legend (Surface Ink Print): ***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Coil Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/4 Solid CM – White Click to Return to Index Page TRI-224SLD1MBXWH (1000’-White) TRI-224SLD5CBXWH (500’ White) PRODUCT FEATURES: DESCRIPTION: 22/4 Solid CM CONSTRUCTION: This cable consists of two bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: Class 2 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 22 AWG bare copper Stranding Solid Insulation Material PE Nominal Insulation Thickness 0.008” Insulated Conductor Diameter 0.043” Number of Conductors 4 Nominal Lay Length 4.5” Jacket Material PVC Jacket Thickness 0.015” Nominal Overall Cable Diameter 0.140” Approximate Cable Weight (lbs./1000ft) 14 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 30 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black, Red, White and Green Jacket Colors White Legend (Surface Ink Print): ***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/4 Solid CM – 500ft – Beige Click to Return to Index Page TRI-224SLD5CRLBG (Beige) TRI-224SLD5CRLBR(Brown) TRI-224SLD5CRLGN (Green) TRI-224SLD5CRLGR(Gray) TRI-224SLD5CRLOR(Orange)TRI-224SLD5CRLYE(Yellow) PRODUCT FEATURES: DESCRIPTION: 22/4 Solid CM CONSTRUCTION: This cable consists of four bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: Class 2 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 22 AWG bare copper Stranding Solid Insulation Material PE Nominal Insulation Thickness 0.008” Insulated Conductor Diameter 0.043” Number of Conductors 4 Nominal Lay Length 4.5” Jacket Material PVC Jacket Thickness 0.015” Nominal Overall Cable Diameter 0.140” Approximate Cable Weight (lbs./1000ft.) 14 Flame Rating UL 1581 vertical tray flame test ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 30 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Jacket Colors Black, Red, White and Green. BG = Beige / BR = Brown / GN = Green / GR = Gray / OR = Orange / WH = White / YE = Yellow Legend (Surface Ink Print): ***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Coil Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/4 Solid FPLR Cable – Red Click to Return to Index Page TRI-224SLDFPLRFT45CRLRD (500’ Coil) TRI-224SLDFPLRFT41MBXRD (1000’ Box) PRODUCT FEATURES: DESCRIPTION: 22/4 Solid FPLR Cable CONSTRUCTION: This cable consists of four bare copper insulated conductors and an overall jacket. APPROVALS: UL Standard 1424 and 444, NEC Articles 760 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable. CONSTRUCTION PARAMETERS: Conductor 22 AWG bare copper Stranding Solid Insulation Material PVE Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.045” Number of Conductors 4 Nominal Lay Length 4.5” Jacket Material PVC Jacket Thickness 0.020” Nominal Overall Cable Diameter 0.155” Approximate Cable Weight (lbs./1000ft) 20 Flame Rating UL 1581 vertical tray flame test ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 30 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Red, Black, Yellow and Blue Jacket Colors Red Legend (Surface Ink Print): ***FT E164182 (UL) 22AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Packaging: Yes - For Easy Jacket Removal TRI-224SLDFPLRFT41MBXRD (1000’ Box) TRI-224SLDFPLRFT45CRLRD (500’ Coil) Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/4 Stranded CM – White Click to Return to Index Page TRI-224STR1MBXWH (1000’ White) TRI-224STR5CBXWH (500’ White) PRODUCT FEATURES: DESCRIPTION: 22/4 Solid CM CONSTRUCTION: This cable consists of four bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: Class 2 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 22 AWG bare copper Stranding 7/30 Insulation Material PE Nominal Insulation Thickness 0.009” Insulated Conductor Diameter 0.047” Number of Conductors 4 Nominal Lay Length 4.5” Jacket Material PVC Jacket Thickness 0.015” Nominal Overall Cable Diameter 0.150” Approximate Cable Weight (lbs./1000ft) 15 Flame Rating UL 1581 vertical tray flame test ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 32 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Black, Red, White and Green Jacket Colors White Legend (Surface Ink Print): ***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/4 STRANDED CM – 500ft Click to Return to Index Page TRI-224STR5CRLWH (White) TRI-224STR5CRLBG(Beige) TRI-224STR5CRLBR (Brown) TRI-224STR5CRLYL(Yellow) PRODUCT FEATURES: DESCRIPTION: 22/4 Stranded CM CONSTRUCTION: This cable consists of four bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: Class 2 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 22 AWG bare copper Stranding 7/30 Insulation Material PE Nominal Insulation Thickness 0.009” Insulated Conductor Diameter 0.047” Number of Conductors 4 Nominal Lay Length 4.5” Jacket Material PVC Jacket Thickness 0.015” Nominal Overall Cable Diameter 0.150” Approximate Cable Weight (lbs./1000ft.) 15 Flame Rating UL 1581 vertical tray flame test ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 32 pF/ft. Nominal Operating Voltage 300 V RMS max Temperature Rating -20° to 60° C JACKET: Insulation Colors Black, Red, White and Green Jacket Colors WH = White / BG = Beige / BR = Brown / YL = Yellow Legend (Surface Ink Print): ***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Coil Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/4 Stranded CMP – White Click to Return to Index Page TRI-224STRCMPFT61MBXWH (1000’) PRODUCT FEATURES: DESCRIPTION: 22/4 Stranded CMP CONSTRUCTION: This cable consists of four tinned copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: Class 2 General Purpose Power Limited Circuit Cable and Communication Cable for Plenum Applications. CONSTRUCTION PARAMETERS: Conductor 22 AWG tinned copper Stranding 7/30 Insulation Material Low Smoke PVC Nominal Insulation Thickness 0.008” Insulated Conductor Diameter 0.045” Number of Conductors 4 Nominal Lay Length 4.5” Jacket Material Low Smoke PVC Jacket Thickness 0.015” Nominal Overall Cable Diameter 0.138” Approximate Cable Weight (lbs./1000ft) 15 Flame Rating UL 910 Steiner Tunnel Smoke and Flame Test ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 25 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Red, Black, White and Green Jacket Colors White Legend (Surface Ink Print): ***FT E164061 (UL) 22AWG TYPE CMP DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/6 Stranded Shielded CM Cable – Gray Click to Return to Index Page TRI-226STRSHLDFT4BXGRY (500’) PRODUCT FEATURES: DESCRIPTION: 22/6 Stranded FPL Cable CONSTRUCTION: This cable consists of six bare copper insulated conductors with an overall shield with a drain. The overall assembly has an overall jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications. CONSTRUCTION PARAMETERS: Conductor 22 AWG bare copper Stranding 7/30 Insulation Material PVC Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.050” Number of Conductors 6 Nominal Lay Length 4.0” Shield Material Aluminum/Mylar Drain Wire 22 AWG 7/30 tinned copper Jacket Material PVC Jacket Thickness 0.020” Nominal Overall Cable Diameter 0.187” Approximate Cable Weight (lbs./1000ft) 27 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 35 pF/ft. Nominal Capacitance Between Conductors to Shield@ 1 KHz 63 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Red, Black, White, Green, Yellow and Blue Jacket Colors Gray Legend (Surface Ink Print): ***FT E164061 (UL) 22AWG TYPE CM OR CL3 DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/6 Stranded CM / CL3 – Gray Click to Return to Index Page TRI-226STRSIG5CGRY (500’) PRODUCT FEATURES: DESCRIPTION: 22/6 Stranded CM / CL3 CONSTRUCTION: This cable consists of six bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: Class 2 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 22 AWG bare copper Stranding 7/30 Insulation Material PVC Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.050” Number of Conductors 6 Nominal Lay Length 5.5” Jacket Material PVC Jacket Thickness 0.015” Nominal Overall Cable Diameter 0.180” Approximate Cable Weight (lbs./1000ft) 24 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 32 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Insulation Colors Red, Black, White, Green, Yellow and Blue Jacket Colors Gray Legend (Surface Ink Print): ***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com MULTI CONDUCTOR CABLES: 22/12 Stranded CM – Gray Click to Return to Index Page TRI-2212STR5CBXGRY (1000’) PRODUCT FEATURES: DESCRIPTION: 22/12 Stranded CMP CONSTRUCTION: This cable consists of 12 bare copper insulated conductors with an overall extruded jacket. APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800. APPLICATION: Class 2 General Purpose Power Limited Circuit Cable and Communications Cable. CONSTRUCTION PARAMETERS: Conductor 22 AWG bare copper Stranding 7/30 Insulation Material PVC Nominal Insulation Thickness 0.010” Insulated Conductor Diameter 0.047” Number of Conductors 12 Nominal Lay Length 6.0” Jacket Material PVC Jacket Thickness 0.018” Nominal Overall Cable Diameter 0.220” Approximate Cable Weight (lbs./1000ft) 43 Flame Rating UL 1581 vertical tray flame test. ELECTRICAL PROPERTIES: Nominal DC Resistance per Conductor @ 20° C 16.19 Ohms/1000ft. Nominal Capacitance Between Conductors @ 1 KHz 32 pF/ft. Nominal Operating Voltage 300 V RMS max. Temperature Rating -20° to 60° C JACKET: Red, Black, White, Green, Brown, Blue, Orange, Yellow, Purple, Gray, Pink and Beige Insulation Colors Jacket Colors Gray Legend (Surface Ink Print): ***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9 Ripcord Yes - For Easy Jacket Removal Packaging Box Connectivity • Security • Solutions For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com