Rev. 14-02 - Tri-Ed

advertisement
Rev. 14-02
CABLE INDEX
Click to
Return to
Index Page
Click Model Number to See Spec
Coax Cables:
TRI-RG59SIAM1000BK | 500BK.................................................................. RG59U + 18/2 Zipped Bulk Cable.............. 3
TRI-RG59SIAM1000WH | 500WH.............................................................. RG59U + 18/2 Zipped Bulk Cable.............. 4
TRI-RG59182BCSIAM500BK | 500WH............................RG59U + Two Bare Copper 18AWG Conductors.............. 5
TRI-RG6QUAD1MWHBX | 5WHBX...................................................................RG 6/U Coaxial Cable – White.............. 6
TRI-RG6U1MBK.....................................................................................................RG 6/U Coaxial Cable – Black.............. 7
TRI-RG6UCMR1MBK............................................................................................RG 6/U Coaxial Cable – Black.............. 8
Cat5E | Cat6A Cables:
TRI-CAT5EBLUE | WHITE | YELLOW | GREY | GREEN..............................................................Cat5E Cable.........9-10
TRI-CAT5EDBRLBK......................................................................................................Cat5E Direct Burial Cable.......11-12
TRI-CAT6ABLUE | GN | GRAY | WH | YL.................23 AWG CAT6A CMR High-Performance Data Cable.......13-14
Multi Conductor Cables:
TRI-142SLDFPLRFT41MBXRD........................................................................................14/2 Solid FPLR Cable............15
TRI-142SLDFPLR5CBXRD................................................................................................14/2 Solid FPLR Cable............16
TRI-142SLDFPLP1MRLRD...............................................................................................14/2 Solid FPLP Cable............17
TRI-162SLDFPLRFT45CBXRD | 41MBXRD...................................................................16/2 Solid FPLR Cable............18
TRI-162SLDFPLR1MRLRD...............................................................................................16/2 Solid FPLR Cable............19
TRI-164SLDFPLR5CBXRD................................................................................................16/4 Solid FPLR Cable............20
TRI-162STRBL | YL.......................................................................................................16/2 Stranded CM Cable............ 21.
TRI-16265STRWH | PU | BL | YL.......................................................................16/2 Stranded CM/CL2 Cable............22
TRI-164STRBL................................................................................................................16/4 Stranded CM Cable............ 23.
TRI-182SLDFPLRFT41MBXRD | 45CRLRD...................................................................18/2 Solid FPLR Cable............24
TRI-184SLDFPLRFT41MBXRD | 45CBXRD...................................................................18/4 Solid FPLR Cable............25
TRI-182STRFT41MBXGRY | 45CBXGRY....................................................................18/2 Stranded CM Cable............26
TRI-182STRFT41MBXWH | 45CBXWH......................................................................18/2 Stranded CM Cable............27
TRI-182STRCMPFT61MBXBEI.................................................................................18/2 Stranded CMP Cable............28
TRI-184STRFT45CBXGRY............................................................................................18/4 Stranded CM Cable............29
TRI-222SLD1MBXWH | 5CBGWH....................................................................................22/2 Solid CM Cable............30
TRI-222STR1MBXWH...................................................................................................22/2 Stranded CM Cable............31
TRI-222STR5CRLWH | BL | GRN | OR | YL.............................................................22/2 Stranded CM Cable............32
TRI-224SLD1MBXWH | 5CBXWH.....................................................................................22/4 Solid CM Cable............33
TRI-224SLD5CRLBG | BR | GN | GR | OR | YE..............................................................22/4 Solid CM Cable............34
TRI-224SLDFPLRFT41MBXRD | 45CRLRD...................................................................24/4 Solid FPLR Cable............35
TRI-224STR1MBXWH | 5CBXWH..............................................................................22/4 Stranded CM Cable............36
TRI-224STR5CRLWH | BR | BG | YL.........................................................................22/4 Stranded CM Cable............37
TRI-224STRCMPFT61MBXWH................................................................................22/4 Stranded CMP Cable............38
TRI-226STRSHLDFT4BXGRY...................................................................... 22/6 Stranded Shielded CM Cable............39
TRI-226STRSIG5CGRY........................................................................................22/6 Stranded CM / CL3 Cable............40
TRI-2212STR5CBXGRY............................................................................................22/12 Stranded CMP Cable............41
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
COAX CABLES:
RG59U+18/2 Zipped Bulk Cable
Click to
Return to
Index Page
TRI-RG59SIAM1000BK (1000’ Black)
TRI-RG59SIAM500BK (500’ Black)
PRODUCT FEATURES:
DESCRIPTION:
RG59U + 18/2 Zipped Bulk Cable
CONSTRUCTION:
This cable consists of a single RG59U cable and two 18 gauge conductors in a single
jacket which can be easily separated.
APPROVALS:
UL / CM / CL2.
APPLICATION:
Designed for use with CCTV equipment. All wires are within one easy to separate PVC jacket.
This single, easy to install cable eliminates the need for two separate power and video cables,
saving you time during installation.
CONSTRUCTION PARAMETERS:
Conductor (Video)
20 AWG Bare Copper Conductor
Insulation Material (Video)
Gas Injected Foam Polyethylene Dielectric
Shielding (Video)
95%
Conductor (Power)
18 AWG
Number of Conductors (Power)
2
Jacket Material (Video/Power)
PVC
Nominal Impedance
75 OHMs
ELECTRICAL PROPERTIES:
Nominal Attenuation Mhz
ELECTRICAL
Db/1000
ft
1Mhz
PROPERTIES:
0.33
Velocity of Prop.
Nominal Attenuation
Mhz
10Mhz
0.88
50Mhz 100Mhz 200Mhz 400Mhz 700Mhz 900Mhz
1.85
2.51
3.58
5.29
7.45
8.7
1000Mhz
9.31
82%
16.19 Ohms/1000ft. Nominal
82%1000 ft
JACKET:
Overall
Color
VelocityJacket
of Prop.
Insulation Colors (Power)
Black
82%
Black and Red
JACKET:
Legend (Surface Ink Print):
***CCTV COMBO RG59/U CM BLACK 95% COPPER UL D-E311791 LOT # XXXXXXXX 1000FT
Packaging
TRI-RG59SIAM1000BK — Wooden Spool - In Box (1000’)
TRI-RG59SIAM500BK — Pull Box (500’)
TRI-RG59SIAM1000BK (37 lbs)
TRI-RG59SIAM500BK (20 lbs)
Weight
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
COAX CABLES:
RG59U+18/2 Zipped Bulk Cable
Click to
Return to
Index Page
TRI-RG59SIAM1000WH (1000’ White)
TRI-RG59SIAM500WH (500’ White)
PRODUCT FEATURES:
DESCRIPTION:
RG59U + 18/2 Zipped Bulk Cable
CONSTRUCTION:
This cable consists of a single RG59U cable and two 18 gauge conductors in a single
jacket which can be easily separated.
APPROVALS:
UL / CM / CL2.
APPLICATION:
Designed for use with CCTV equipment. All wires are within one easy to separate PVC jacket.
This single, easy to install cable eliminates the need for two separate power and video cables,
saving you time during installation.
CONSTRUCTION PARAMETERS:
Conductor (Video)
20 AWG Bare Copper Conductor
Insulation Material (Video)
Gas Injected Foam Polyethylene Dielectric
Shielding (Video)
95%
Conductor (Power)
18 AWG
Number of Conductors (Power)
2
Jacket Material (Video/Power)
PVC
Nominal Impedance
75 OHMs
ELECTRICAL PROPERTIES:
Nominal Attenuation Mhz
ELECTRICAL
Db/1000
ft
1Mhz
PROPERTIES:
0.33
10Mhz
0.88
50Mhz 100Mhz 200Mhz 400Mhz 700Mhz 900Mhz
1.85
2.51
3.58
Velocity of Prop.
5.29
7.45
8.7
1000Mhz
9.31
82%
JACKET:
Overall Jacket Color
White
Insulation Colors (Power)
Black and Red
Legend (Surface Ink Print):
***CCTV COMBO RG59/U CM WHITE 95% COPPER UL D-E311791 LOT # XXXXXXXX 1000FT
Packaging
TRI-RG59SIAM1000WH — Wooden Spool - In Box (1000’)
TRI-RG59SIAM500WH — Pull Box (500’)
TRI-RG59SIAM1000WH (37 lbs)
TRI-RG59SIAM500WH (20 lbs)
Weight
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
COAX CABLES:
RG59U Coaxial Cable + Two Bare Copper 18AWG Conductors
Click to
Return to
Index Page
TRI-RG59182BCSIAM500BK (500’ Black)
TRI-RG59182BCSIAM500WH (500’ White)
PRODUCT FEATURES:
DESCRIPTION:
RG59U Coaxial Cable + Two Bare Copper 18AWG Conductors
CONSTRUCTION:
This cable consists of a single RG59U cable and two 18 gauge conductors in a single
jacket which can be easily separated
APPROVALS:
NEC Article 725 and 820.
APPLICATION:
Designed for use with CCTV equipment. All wires are within one easy to separate PVC jacket.
This single, easy to install cable eliminates the need for two separate power and video cables,
saving you time during installation.
.
CONSTRUCTION PARAMETERS:
Conductor
RG59: 20 AWG(1/0.032”) BC 2×, 18AWG Conductor: 7/26 BareCopper
Dielectric
RG59: Foam PE 18AWG Conductor: PVC
Nom. Dielectric Wall Thickness
RG59: 0.057” 18AWG Conductor: 0.010”
Nom. Dielectric Diameter
RG59: 0.146” 18AWG Conductor: 0.068”
Shield / Nom. Shield Diameter
95% CCA Braid / 0.174
Jacket Material / Jacket Thickness
PVC / 0.034”
Nom. Overall Cable Diameter
0.236” * 0.493”
Flame Rating
UL1581 Vertical Tray Flame Test
ELECTRICAL PROPERTIES (RG 59):
Frequency (Mhz)
50
100
200
400
700
1000
Max. Attentuation
(dB/1000 ft) @ 20ºC
1.9
2.5
3.6
5.0
6.9
8.5
Impedence
(Ohms)
Velocity of
Propagation (%)
DC Resistance
(Ω/mft.) @ 20ºC
Nom. Capacitance
75 ± 3
78
10.2
16.3 pF/ft.
JACKET:
Overall Jacket Color / Insulation Colors (Power)
BK = Black or WH = White / Black and Red
Legend (Surface Ink Print):
Jacket is sequentially foot marked
CCTV RG59 20AWG SOL BC95% CCA BRD+18/2 CM UL C (UL) E354460 75C ROHS COMPLIANT DC 0413 ZONE 0 1 2 3 4 5 6 7 8 9
Packaging / Weight
Pull Box (500’) / 23 lbs
Max. Temperature Rating
60ºC
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
COAX CABLES:
RG 6/U COAXIAL CABLE – White
Click to
Return to
Index Page
TRI-RG6QUAD5WHBX (500’ White)
TRI-RG6QUAD1MWHBX (1000’ White)
PRODUCT FEATURES:
DESCRIPTION:
RG 6/U COAXIAL CABLE WITH TWO FOILS PLUS 40% AND 60% ALUMINUM BRAID
APPROVALS:
NEC Article 725 and 820
CONSTRUCTION PARAMETERS:
Conductor
18 AWG (1/0.040”) solid CCS
Dielectric
Foam PE
Nominal Dielectric Wall Thickness
0.070”
Nominal Dielectric Diameter
0.180”
Shielding 1 & 2
Bonded Polyester/Aluminum Tape and 60% Aluminum Braid
Shielding 3 & 4
Polyester/Aluminum Tape and 40% Aluminum Braid
Nominal Overall Shield Diameter
0.249”
Jacket Material
PVC
Jacket Thickness
0.032”
Nominal Overall Cable Diameter
0.300”
Approximate Cable Weight (lbs./1000ft)
26
Flame Rating
UL1581 Vertical Tray Flame Test
Max Temperature Rating
75° C
ELECTRICAL PROPERTIES:
Detailed
Electrical Properties Available
Frequency
55
250 300 350
MHz
Max Attenuation
(dB/100m) @ 20°C
1.6
3.36
3.7
4.01
450
500
750
4.58
4.84
6
Please See Chart on Page 2
1000 1200 1400 1500 1700 1900
7
7.5
8.1
8.4
8.9
9.6
2000
9.8
Impedance (Ohms)
Min. Velocity of Propagation (%)
DC Resistance (Ω/mft.) @ 20°C
Nominal Capacitance
75±3
78
33
16.2pF/ft.
JACKET:
Jacket Colors
White
Legend (Surface Ink Print):
***FT RG6/U 18 AWG QUAD SHIELD DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
COAX CABLES:
RG6/U COAXIAL CABLE – Black
Click to
Return to
Index Page
TRI-RG6U1MBK (1000’)
PRODUCT FEATURES:
DESCRIPTION:
RG-6/U 60% CM CATV 75 Ω Coaxial Cable
CONSTRUCTION:
This cable consists of an 18 AWG solid copper clad steel conductor (CCS).
Foamed polyethylene insulation; 60% Coverage Aluminum Wire Braid shield, PVC jacket.
STANDARDS:
Ref. SCTE IPS-SP-001 — UL 1655, UL 13, UL 444, ROHS Compliant
APPLICATION:
Designed for use with CCTV equipment.
PHYSICAL CHARACTERISTICS:
Conductor
Solid 18 AWG Copper Clad Steel, 0.04” dia.
Insulation Material
Foamed Polyethylene, Nom Thickness 0.073”, Dia. 0.186”
Braid Shield
Aluminum Wire 60% Coverage Area, 0.213” Braid Dia.
Jacket
PVC, 0.2716” Cable Dia., Nom. Thickness 0.0295
ELECTRICAL CHARACTERISTICS:
Temperature Rating
-20˚ ~ 60˚ C
Impedance
75 Ohms (±3.0 Ohms)
Capacitance
15.5 (pF/ft)
Conductor DCR@20˚ C
28.6 (Ohms/1000ft)
Velocity of Propagation
84%
ELECTRICAL PERFORMANCE:
Frequency
5
Mhz
55
Mhz
211
Mhz
250
Mhz
270
Mhz
300
Mhz
350
Mhz
400
Mhz
450
Mhz
500
Mhz
Nom. Attentuation
(Db/100 ft)
2.66
5.25
10.10
11.02
11.48
12.14
13.15
14.11
15.03
15.88
Frequency
550
Mhz
600
Mhz
750
Mhz
870
Mhz
1000
Mhz
1250
Mhz
1450
Mhz
2200
Mhz
2400
Mhz
3000
Mhz
16.70
17.52
19.69
21.33
22.97
25.00
26.37
31.16
32.83
37.88
Nom. Attentuation
(Db/100 ft)
JACKET:
Jacket / Insulation Colors
Black / White
Legend (Surface Ink Print):
RG6/U 18AWG CMR XXXXXXX VERIFIED TO C(ETL)US CATV SWEPT TO 3.0 GHZ XXXXFT
Packaging / Weight
Pull Box / 29 Lbs
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
COAX CABLES:
RG6/U COAXIAL CABLE – Black
Click to
Return to
Index Page
TRI-RG6UCMR1MBK (1000’)
PRODUCT FEATURES:
DESCRIPTION:
RG6U Bulk CoaxialCable
CONSTRUCTION:
This cable consists of an 18 AWG solid copper covered steel conductor (CCS).
foamed LDPE insulation; overall 100% poly/alum foil tape; overall 65% aluminum braid;
overall black sunlight resistant PVC jacket.
APPROVALS:
Type CL2 / NEC Article 725 / UL 1581
APPLICATION:
Designed for use with CCTV equipment.
CONSTRUCTION PARAMETERS:
Conductor
solid 18 AWG copper covered steel, Outer Dia. 0.180”
Insulation Material
Foamed LDPE, Nominal Wall Thickness 0.070”, white
Shielding
Jacket
100% Coverage Bonded Poly/Alum tape — 65% Coverage Aluminum braid
Sunlight Resistant PVC,0.032” Nominal Thickness, Outer Dia. 0.254”
ELECTRICAL PROPERTIES:
Maximum Attenuation (Mhz)
Db/100 ft
50Mhz
100Mhz
200Mhz
400Mhz
700Mhz
1000Mhz
1.46
2.05
2.83
4.15
5.60
6.70
Velocity of Prop.
84%
Temperature
-20° C ~ 75° C
Voltage
300 Volt
Capacitance
16.2 pF/ft. Nom.
Impedance
75 Ohms/M’
DC Resistance
7.5 Ohms/M’ @ 20° C
JACKET:
Overall Jacket Color
Black
Insulation Colors
White
Legend (Surface Ink Print):
UPG SR6FA RG6/U 18 AWG (UL) TYPE CMR SUNLIGHT RESISTANT UL Standard 13
Packaging
Pull Box
Weight
30 Lbs.
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
Cat5E CABLES:
Cat 5E 350MHz UTP PVC Cable
TRI-CAT5EBLUE
(1000’)
TRI-CAT5EYELLOW (1000’)
TRI-CAT5EGREEN (1000’)
[Page 1 of 2]
Click to
Return to
Index Page
TRI-CAT5EWHITE (1000’)
TRI-CAT5EGREY (1000’)
GENERAL SPECIFICATIONS:
Cable Type
SPECIFICATION:
Conductor Material
Solid Bare Copper
Jacket Material
Conductor Gauge, singles
24 AWG
Conductor Type, singles
Solid
8
Compliant
MECHANICAL CHARACTERISTICS:
0.483 mm | 0.019 in
Insulation
Blue|White|Yellow|Grey|Green
ISO 9001:2008
5.0 mm | 0.197 in
Conductor Dia.
4
Jacket Colors
RoHS 2002/95/EC
305 m | 1000 ft
Diameter Over Jacket (±0.2mm)
Pairs, quantity
Conductors, quantity
PVC
Cable Length
U/UTP (unshielded)
Polyethylene (PE)
Test Object
Jacket
Average Thickness(±0.03mm)
0.21 mm | 0.008 in
Test Material
Min. Point Thickness
0.2 mm | 0.007 in
Before Tensile Strength (Mpa)
Insulation Dia.(±0.03mm)
0.9 mm | 0.035 in
Aging Elongation (%)
>=100
Twisting Lay Length
30 mm | 1.181 in
Aging Condition ( xhrs)
100x240
Cabling Lay Length(±20mm)
(±20mm) 100 mm | 3.937 in
Min. Point Thickness
0.43 mm | 0.016 in
Rip Cord
PVC
>=13.8
After Tensile Strength (Mpa)
>=85% of unaged
Aging Elongation (%)
>=50% of unaged
Cold Bend(-20±2 x4hrs)
YES
No crack
ELECTRICAL SPECIFICATION:
ANSI/TIA Category
5E
Transmission Standards
ANSI/TIA-568-C.2 | ISO/IEC 11801 Class D
Reference Standard
YD/T1019-2001, UL Subject 444
Product Standard Certification
UL File E222804
1.0-100.0MHz Impedance (ohms)
100 ± 15
100-200MHz Impedance (ohms)
100 ± 25
200-350MHz Impedance (ohms)
100 ± 35
1.0-100.0MHz Delay Skew (ns/100m)
<=45
Pair-to-Ground Capacitance Unbalance (pF/100m)
<=330
Max. Conductor DC Resistance 20 (ohms/km)
93.8
Resistance Unbalance (%)
<=5
Installation Temperature
0 °C to +60 °C (+32 °F to +140 °F)
Operating Temperature
-20 °C to +60 °C (-4 °F to +140 °F)
Detailed Electrical Characteristics Continued
Connectivity
Please See Chart on Page 2
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
Cat5E CABLES:
Cat 5E 350MHz UTP PVC Cable
TRI-CAT5EBLUE
(1000’)
TRI-CAT5EYELLOW (1000’)
TRI-CAT5EGREEN (1000’)
[Page 2 of 2]
Click to
Return to
Index Page
TRI-CAT5EWHITE (1000’)
TRI-CAT5EGREY (1000’)
ELECTRICAL PROPERTIES:
Frequency Return Loss
Attentuation
NEXT
ACR
PSNEXT
(MHz)
(dB)
(dB/100m)
(dB)
(dB)
(dB)
0.772
19.4
1.8
67
65
64
66
63
575
1
20
2
65.3
63
62.3
63.8
60.8
570
4
23
4.1
56.3
52
53.3
51.7
48.7
552
8
24.5
5.8
51.8
46
48.8
45.7
42.7
546.7
10
25
6.5
50.3
44
47.3
43.8
40.8
545.4
16
25
8.2
47.3
39
44.3
39.7
36.7
543
20
25
9.3
45.8
37
42.8
37.7
34.7
542
25
24.3
10.4
44.3
34
41.3
35.8
32.8
541.2
31.25
23.6
11.7
42.9
31
39.9
33.9
30.9
540.4
62.5
21.5
17
38.4
21
35.4
27.8
24.8
538.6
100
20.1
22
35.3
13
32.3
23.8
20.8
537.6
250
17.6
36.8
29.3
-12.3
26.3
15.8
12.8
494.2
350
16.3
44.8
27.1
-18.5
24.1
12.9
9.9
472.4
Connectivity
•
Security
•
ELFEXT
PSELFEXT
Delay
(dB/100m) (dB/100m) (ns/100m)
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
Cat5E CABLES:
24 AWG / 4 PAIRS RISER CATEGORY 5e
PLUS UTP DATA CABLE
[Page 1 of 2]
Click to
Return to
Index Page
TRI-CAT5EDBRLBK
PRODUCT FEATURES:
DESCRIPTION:
24 AWG / 4 PAIRS RISER CATEGORY 5e PLUS UTP DATA CABLE
RATING:
UL LISTED CMR
APPROVALS:
NEC Article 800, ANSI/TIA/EIA-568-B.2 Category 5e and UL Verified to Category 5e
APPLICATION:
Direct Burial, designed for use with CCTV equipment.
CONSTRUCTION PARAMETERS:
Conductor
24 AWG solid bare copper
Insulation Material
PE
Nominal Insulation Thickness
0.008”
Insulated Conductor Diameter
0.036”
Pair Lays
Each pair has different lay length for cross-talk prevention
Jacket Material
PVC
Jacket Thickness
0.020”
Nominal Overall Cable Diameter
0.220”
Approximate Cable Weight (lbs./1000ft)
22
Flame Rating
UL 1666 riser
ELECTRICAL PROPERTIES:
Impedance(Ohms)
1~100MHZ
100±15
100~200MHz 200~350MHz
100±22
100±32
Delay Skew
Velocity of
Max. Cap.
Max. Cap.
(ns/100m)
Propagation
DC Resistance DC Resistance
(Ω/100m)
Unbalance (%)
@1000Hz
Unbalance
20
70(%)
9.2 @ 20°C
3
15 pF/ft.
300 pF/100m
Detailed Electrical Properties Continued
Please See Chart on Page 2
JACKET:
Insulation Colors
Blue/White with Blue, Orange/White with Orange,
Green/White with Green, Brown/White with Brown
Jacket Color
BLK = Black
Legend (Surface Ink Print):
***FT E164061 VERIFIED (UL) CAT 5e Plus 24AWG TYPE CMR TO TIA/EIA-568-B.2 UTP DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Reel
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
Cat5E CABLES:
24 AWG / 4 PAIRS RISER CATEGORY 5e
PLUS UTP DATA CABLE
Click to
Return to
Index Page
[Page 2 of 2]
TRI-CAT5EDBRLBK
ELECTRICAL PROPERTIES:
Frequency
MHz
Max Attenuation
(dB/100m) @ 20°C
Min NEXT
(dB/100m)
Min ELFEXT
(dB/100m)
Min PS-ELFEXT
(dB/100m)
1
1.9
68.3
66.3
20
64
61
4
3.8
59.3
57.3
23
52
49
8
5.5
54.8
52.8
24.5
46
43
10
6.1
53.3
51.3
25
44
41
16
7.8
50.3
48.3
25
40
37
20
8.8
48.8
46.8
25
38
35
25
9.9
47.3
45.3
24.3
36
33
31.25
11.1
45.9
43.9
23.6
34
31
62.5
16.1
41.4
39.4
21.5
28
25
100
20.9
38.3
36.3
20.1
24
21
155
26.7
35.5
33.5
18.8
20
17
200
30.8
29.8
27.8
18
12
11
250
35
28.3
26.3
17.3
10
9
300
38.9
27.2
25.2
16.8
8.2
7.2
350
42.6
26.2
24.2
16.3
7
6
Connectivity
Min PS-NEXT
Min Return
(dB/100m) Loss (dB/100m)
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
Cat6A CABLES:
23 AWG CAT6A CMR
HIGH-PERFORMANCE DATA CABLE
TRI-CAT6ABLUE (1000’–Blue)
TRI-CAT6AYL (1000’–Yellow)
TRI-CAT6AGN (1000’–Green)
Click to
Return to
Index Page
[Page 1 of 2]
TRI-CAT6AWH (1000’–White)
TRI-CAT6AGRAY (1000’–Grey)
Outer Aerated Jacket
23 AWG Conductor
T-Top Separator
Insulation
SPECIFICATION:
Number of Conductor Pairs
4
Size
23 AWG
Stranding
DESCRIPTION / STANDARDS:
Solid
Conductor Material
Solid Annealed Bare Copper
• 23 AWG CAT6A CMR, High-Performance Data Cable
Shield Material
• ETL Listed Type CMR
Rip Cord
• C(ETL) listed CMG FT4
Insulation Material
• TIA - 568-C.2, and ISO/IEC 11801
Insulation Overall Diameter
• ROHS Compliant
Insulation Average Thickness
• ATM 155 Mbps
Jacket
• Ethernet 10BASE-T, 100BASE-TX, 100BASE-VG, 100BASE-T4,
Outer Jacket Avg Wall Thickness
• 1000 Mbps 1000BASE-T Gigabit Ethernet™ (IEEE 802.3)
Outer Jacket Nominal O.D.
• 16 Mbps Token Ring™ (IEEE 802.5)
Nominal Weight
MECHANICAL CHARACTERISTICS:
COLOR CODE / CABLE MARKING:
Temperature Rating (Installation)
0 to + 60°C
Pair 1
White / Blue
Blue
Temperature Rating (Operating)
-20°C to + 75°C
Pair 2
White / Orange
Orange
Tensile Strength (Before Aging)
> = 13.8 Mpa
Pair 3
White / Green
Green
> = 100%
Pair 4
White / Brown
Brown
Elongation (Before Aging)
Aging Condition
100°C x 168 hours
Tensile Strength (After Aging)
> = 85% of unaged
Elongation (After Aging)
> = 50% of unaged
Unshielded
Yes
HDPE
0.04 in. ± 0.0002 in.
0.0086 in.
Flame Retardant PVC
0.022 in.
0.3 in. ± 0.008 in.
55 lbs.
Legend (Surface Ink Print):
E223070 23AWG 4PR UTP CMR 75C C(UL)US VERIFIED (UL)
CATEGORY 6A ANSI/TIA-568-C.2 XXXXFT
ELECTRICAL SPECIFICATION:
Maximum Conductor DC Resistance @ 20°C
6.85 Ω / 100 Meters
Maximum DC Resistance Unbalanced @ 20°C
5%
Maximum Pair-to-Pair Ground Capacitance Unbalanced
330 pF / 100 Meters
Characteristic Impedance
100 ± 15 Ω
Mutual Capacitance
5.6 nF / 100 Meters
Maximum Delay Skew
40 nS / 100 Meters
Detailed Electrical Characteristics Continued
Connectivity
Please See Chart on Page 2
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
Cat6A CABLES:
23 AWG CAT6A CMR
HIGH-PERFORMANCE DATA CABLE
TRI-CAT6ABLUE (1000’–Blue)
TRI-CAT6AYL (1000’–Yellow)
TRI-CAT6AGN (1000’–Green)
Click to
Return to
Index Page
[Page 2 of 2]
TRI-CAT6AWH (1000’–White)
TRI-CAT6AGRAY (1000’–Grey)
Outer Aerated Jacket
23 AWG Conductor
T-Top Separator
Insulation
ELECTRICAL PROPERTIES:
Frequency
Attentuation
Return Loss
NEXT
PS-NEXT
ELFEXT
PS-ELFEXT
Delay
(MHz)
Max. (dB/100m)
Min. (dB)
Min. (dB)
Min. (dB)
Min. (dB)
Min. (dB)
Min. (dB)
1
1.9
20
74.3
72.3
67.8
64.8
570
4
3.78
23.01
65.24
63.27
55.76
52.76
552
10
5.95
25
59.3
57.3
47.8
44.8
545
16
7.55
25
56.24
54.24
43.72
40.72
543
20
8.47
25
54.78
52.78
41.78
38.78
542
21.25
10.67
23.64
51.88
49.88
37.9
34.9
540
62.5
15.38
21.54
47.36
45.36
31.88
28.8
538
100
19.8
20.11
44.3
42.3
27.8
24.8
537
200
28.98
18
39.78
37.78
21.78
18.78
536
250
32.85
17.32
38.33
36.33
19.84
16.84
536
400
42.96
15.89
35.2
33.2
15.9
12.9
535
500
48.92
15.21
33.8
31.8
14.02
11.02
535
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
14/2 Solid FPLR Cable – Red
Click to
Return to
Index Page
TRI-142SLDFPLRFT41MBXRD (1000’)
PRODUCT FEATURES:
DESCRIPTION:
14/2 Solid FPLR Cable.
CONSTRUCTION:
This cable consists of two bare copper insulated conductors and an overall jacket.
APPROVALS:
UL Standard 1424 and NEC Article 760.
APPLICATION:
Power Limited Fire Alarm Circuit Cable for Riser Applications.
CONSTRUCTION PARAMETERS:
Conductor
14 AWG Bare Copper
Stranding
Solid
Insulation Material
PVC
Nominal Insulation Thickness
0.015”
Insulated Conductor Diameter
0.090”
Number of Conductors
2
Nominal Lay Length
5.5”
Jacket Material
PVC
Jacket Thickness
0.020”
Nominal Overall Cable Diameter
0.230”
Approximate Cable Weight (lbs./1000ft.)
40
Flame Rating
UL 1666 Riser Flame Test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
2.52 Ohms/1000ft. nominal
Capacitance Between Conductors @ 1 KHz
42 pF/ft. nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black and Red
Jacket Colors
Red
Legend (Surface Ink Print):
***FT E164182 (UL) 14AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
14/2 Solid FPLR Cable – Red
Click to
Return to
Index Page
TRI-142SLDFPLR5CBXRD (500’)
PRODUCT FEATURES:
DESCRIPTION:
14/2 Solid FPLR Cable.
CONSTRUCTION:
This cable consists of two bare copper insulated conductors and an overall jacket.
APPROVALS:
UL Standard 1424 and NEC Article 760.
APPLICATION:
Power Limited Fire Alarm Circuit Cable for Riser Applications.
CONSTRUCTION PARAMETERS:
Conductor
14 AWG Bare Copper
Stranding
Solid
Insulation Material
PVC
Nominal Insulation Thickness
0.015”
Insulated Conductor Diameter
0.090”
Number of Conductors
2
Nominal Lay Length
5.5”
Jacket Material
PVC
Jacket Thickness
0.020”
Nominal Overall Cable Diameter
0.230”
Approximate Cable Weight (lbs./1000ft.)
40
Flame Rating
UL 1666 Riser Flame Test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
2.52 Ohms/1000ft. nominal
Capacitance Between Conductors @ 1 KHz
42 pF/ft. nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black and Red
Jacket Colors
Red
Legend (Surface Ink Print):
***FT E164182 (UL) 14AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
14/2 Solid FPLP Cable – Red
Click to
Return to
Index Page
TRI-142SLDFPLP1MRLRD (1000’)
PRODUCT FEATURES:
DESCRIPTION:
14/2 Solid FPLP Cable
CONSTRUCTION:
This cable consists of two bare copper insulated conductors and an overall jacket.
APPROVALS:
UL Standard 1424 and NEC Article 760.
APPLICATION:
Power Limited Fire Alarm Circuit Cable Used in Plenum Applications..
CONSTRUCTION PARAMETERS:
Conductor
14 AWG bare copper
Stranding
Solid
Insulation Material
Low Smoke PVC
Nominal Insulation Thickness
0.013”
Insulated Conductor Diameter
0.090”
Number of Conductors
2
Nominal Lay Length
5.0”
Jacket Material
Low Smoke PVC
Jacket Thickness
0.015”
Nominal Overall Cable Diameter
0.210”
Approximate Cable Weight (lbs./1000ft)
37
Flame Rating
UL 910 Steiner Tunnel Smoke and Flame Test
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
2.52 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
42 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Red and Black
Jacket Colors
Red
Legend (Surface Ink Print):
***FT E164061 (UL) 14AWG TYPE FPLP DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Reel
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
16/2 Solid FPLR Cable – Red
Click to
Return to
Index Page
TRI-162SLDFPLRFT45CBXRD (500’)
TRI-162SLDFPLRFT41MBXRD (1000’)
PRODUCT FEATURES:
DESCRIPTION:
16/2 Solid FPLR Cable
CONSTRUCTION:
This cable consists of two bare copper insulated conductors and an overall jacket.
APPROVALS:
UL Standard 1424 and 444, NEC Articles 760 and 800.
APPLICATION:
Power Limited Fire Alarm Circuit Cable and Communication Cable.
CONSTRUCTION PARAMETERS:
Conductor
16 AWG bare copper
Stranding
Solid
Insulation Material
PVC
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.070”
Number of Conductors
2
Nominal Lay Length
5.0”
Jacket Material
PVC
Jacket Thickness
0.025”
Nominal Overall Cable Diameter
0.190”
Approximate Cable Weight (lbs./1000ft.)
30
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
4.02 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
40 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black, Red
Jacket Colors
Red
Legend (Surface Ink Print):
***FT E164182 (UL) 16AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
16/2 Solid FPLR Cable – Red
Click to
Return to
Index Page
TRI-162SLDFPLR1MRLRD (1000’)
PRODUCT FEATURES:
DESCRIPTION:
16/2 Solid FPLR Cable
CONSTRUCTION:
This cable consists of 2 conductors 16 AWG solid bare copper; color-coded PVC insulation;
overall red PVC jacket.
APPROVALS:
Type FPLR; UL Standard 1424; NEC Article 760; UL 1581.
APPLICATION:
Power Limited Fire Alarm Circuit Cable and Communication Cable.
CONSTRUCTION PARAMETERS:
Conductor
16 AWG solid bare copper
Insulation Material
PVC
Nominal Insulation Thickness
0.011”
Number of Conductors
2
Jacket Material
PVC
Jacket Thickness
0.020”
Nominal Overall Cable Diameter
0.186”
Approximate Cable Weight (lbs./1000ft.)
23 Lbs.
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
DC Resistance
4.2 Ohms/M’ @ 20° C
Capacitance Between Conductors
40.6 pF/ft. Nominal @ 1 MHz
Impedance
54 Ohms
Velocity of Propagation
46.6%
Operating Voltage
300 Volt
Temperature Rating
-20° to 75° C
JACKET:
Insulation Colors
Black, Red
Jacket Colors
Legend (Surface Ink Print):
Red
16/2C SOL FIRE FPLR (****) 75° c XXXXXX (***) ROHS COMPLIANT (**) (*)
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
16/4 Solid FPLR Cable – Red
Click to
Return to
Index Page
TRI-164SLDFPLR5CBXRD (500’)
PRODUCT FEATURES:
DESCRIPTION:
16/4 Solid FPLR Cable
CONSTRUCTION:
This cable consists of four bare copper insulated conductors and an overall jacket.
APPROVALS:
UL Standard 1424 and 444, NEC Articles 760 and 800.
APPLICATION:
Power Limited Fire Alarm Circuit Cable and Communication Cable.
CONSTRUCTION PARAMETERS:
Conductor
16 AWG bare copper
Stranding
Solid
Insulation Material
PVC
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.070”
Number of Conductors
4
Nominal Lay Length
6.0”
Jacket Material
PVC
Jacket Thickness
0.020”
Nominal Overall Cable Diameter
0.225”
Approximate Cable Weight (lbs./1000ft)
55
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
4.02 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
40 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black, Red, Blue and Yellow
Jacket Colors
Red
Legend (Surface Ink Print):
***FT E164182 (UL) 16AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
16/2 Stranded CM – Black or Yellow
Click to
Return to
Index Page
TRI-162STRBL (500’ Black)
TRI-162STRYL (500’ Yellow)
PRODUCT FEATURES:
DESCRIPTION:
16/2 Stranded CM
CONSTRUCTION:
This cable consists of two bare copper insulated conductors and an overall core wrap.
The overall assembly has an overall extruded jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
General Purpose Power Limited Circuit Cable and Communications Cable
Used in Audio Applications.
CONSTRUCTION PARAMETERS:
Conductor
16 AWG bare copper
Stranding
26/30
Insulation Material
FR-PVC
Nominal Insulation Thickness
0.012”
Insulated Conductor Diameter
0.080”
Number of Conductors
2
Nominal Lay Length
2.4”
Jacket Material
Extra Flexible FR-PVC
Core Wrap
Nonwoven
Jacket Thickness
0.026”
Nominal Overall Cable Diameter
0.212”
Approximate Cable Weight (lbs./1000ft)
29
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
4.02 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
30 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black and Red
Jacket Colors
BL = Black / YL = Yellow
Legend (Surface Ink Print):
***FT OXYGEN FREE COPPER E164061 (UL) 16AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
16/2 Stranded CM/CL2 – 500ft – White
TRI-16265STRWH(White)
TRI-16265STRBL (Blue)
Click to
Return to
Index Page
TRI-16265STRPU(Purple)
TRI-16265STRYL(Yellow)
PRODUCT FEATURES:
DESCRIPTION:
16/2 Stranded CM/CL2 Cable
CONSTRUCTION:
This cable consists of two Oxygen Free bare copper insulated conductors and an overall
core wrap. The overall assembly has an overall extruded jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
General Purpose Power Limited Circuit Cable and Communications Cable used
in Audio Applications.
CONSTRUCTION PARAMETERS:
Conductor
16 AWG Oxygen Free bare copper
Stranding
65/34
Insulation Material
FR-PVC
Nominal Insulation Thickness
0.012”
Insulated Conductor Diameter
0.080”
Number of Conductors
2
Nominal Lay Length
2.4”
Jacket Material
Extra Flexible FR-PVC
Core Wrap
Nonwoven
Jacket Thickness
0.026”
Nominal Overall Cable Diameter
0.212”
Approximate Cable Weight (lbs./1000ft.)
29
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
4.02 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
30 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black and Red
Jacket Colors
WH=White, PU=Purple, BL=Blue, YL=Yellow
Legend (Surface Ink Print):
UPG 1602 16/2 (65/34) OFC HI-FLEX AUDIO CM UL (C) UL E35460 75C ROHS COMPLIANT DC 0513 ZONE 1 2 3 4 5 6 7 8 9
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
16/4 STRANDED CM CABLE – Blue
Click to
Return to
Index Page
TRI-164STRBL (500’)
PRODUCT FEATURES:
DESCRIPTION:
16/4 Stranded CM Cable
CONSTRUCTION:
This cable consists of four bare copper insulated conductors and an overall core wrap.
The overall assembly has an overall extruded jacket..
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
General Purpose Power Limited Circuit Cable and Communications Cable
Used in Audio Applications.
CONSTRUCTION PARAMETERS:
Conductor
16 AWG bare copper
Stranding
26/30
Insulation Material
FR-PVC
Nominal Insulation Thickness
0.012”
Insulated Conductor Diameter
0.080”
Number of Conductors
4
Nominal Lay Length
5.1”
Jacket Material
Extra Flexible FR-PVC
Core Wrap
Nonwoven
Jacket Thickness
0.023”
Nominal Overall Cable Diameter
0.24”
Approximate Cable Weight (lbs./1000ft)
50
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
4.02 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
30 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black, Red, White and Green
Jacket Colors
Blue
Legend (Surface Ink Print):
***FT OXYGEN FREE COPPER E164061 (UL) 16AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
18/2 Solid FPL Cable – Red
Click to
Return to
Index Page
TRI-182SLDFPLRFT45CRLRD (500’)
TRI-182SLDFPLRFT41MBXRD (1000’)
PRODUCT FEATURES:
DESCRIPTION:
18/2 Solid FPL Cable
CONSTRUCTION:
This cable consists of two bare copper insulated conductors and an overall jacket.
APPROVALS:
UL Standard 1424 and 444, NEC Articles 760 and 800.
APPLICATION:
Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications.
CONSTRUCTION PARAMETERS:
Conductor
18 AWG bare copper
Stranding
Solid
Insulation Material
PVC
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.060”
Number of Conductors
2
Nominal Lay Length
4.5”
Jacket Material
PVC
Jacket Thickness
0.020”
Nominal Overall Cable Diameter
0.170”
Approximate Cable Weight (lbs./1000ft)
20
Flame Rating
UL 1666 riser flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
6.43 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
35 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Red and Black
Jacket Colors
Red
Legend (Surface Ink Print):
***FT E164182 (UL) 18AWG TYPE FPL DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
18/4 Solid FPLR Cable – Red
Click to
Return to
Index Page
TRI-184SLDFPLRFT45CBXRD (500’)
TRI-184SLDFPLRFT41MBXRD (1000’)
PRODUCT FEATURES:
DESCRIPTION:
18/4 Solid FPLR Cable
CONSTRUCTION:
This cable consists of four bare copper insulated conductors and an overall jacket.
APPROVALS:
UL Standard 1424 and NEC Article 760.
APPLICATION:
Fire Alarm Power Limited Circuit Cable for Addressable Fire Alarm Systems.
CONSTRUCTION PARAMETERS:
Conductor
18 AWG bare copper
Stranding
Solid
Insulation Material
PVC
Nominal Insulation Thickness
0.015”
Insulated Conductor Diameter
0.070”
Number of Conductors
4
Nominal Lay Length
5.0”
Jacket Material
PVC
Jacket Thickness
0.020”
Nominal Overall Cable Diameter
0.230”
Approximate Cable Weight (lbs./1000ft)
40
Flame Rating
UL 1666 riser flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
6.43 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
27 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black, Red, Yellow and Blue
Jacket Colors
Red
Legend (Surface Ink Print):
***FT E164182 (UL) 18AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
18/2 Stranded CM – Gray
Click to
Return to
Index Page
TRI-182STRFT45CBXGRY (500’)
TRI-182STRFT41MBXGRY (1000’)
PRODUCT FEATURES:
DESCRIPTION:
18/2 Stranded CM
CONSTRUCTION:
This cable consists of two bare copper insulated conductors and an overall jacket.
APPROVALS:
UL Standard 13 and UL 444, NEC Articles 725 and 800.
APPLICATION:
Class 3 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
18 AWG bare copper
Stranding
7/26
Insulation Material
PVC
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.066”
Number of Conductors
2
Nominal Lay Length
Parallel
Jacket Material
PVC
Jacket Thickness
0.018”
Nominal Overall Cable Diameter
0.170”
Approximate Cable Weight (lbs./1000ft.)
19
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
6.43 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
32 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black, Red
Jacket Colors
Legend (Surface Ink Print):
Gray
***FT E164061 (UL) 18AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
18/2 Stranded CM – White
Click to
Return to
Index Page
TRI-182STRFT45CBXWH (500’)
TRI-182STRFT41MBXWH (1000’)
PRODUCT FEATURES:
DESCRIPTION:
18/2 Stranded CM
CONSTRUCTION:
This cable consists of two bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and UL 444, NEC Articles 725 and 800.
APPLICATION:
Class 3 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
18 AWG bare copper
Stranding
7/26
Insulation Material
PVC
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.066”
Number of Conductors
2
Nominal Lay Length
Parallel
Jacket Material
PVC
Jacket Thickness
0.018”
Nominal Overall Cable Diameter
0.170”
Approximate Cable Weight (lbs./1000ft.)
19
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
6.43 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
32 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black and Red
Jacket Colors
White
Legend (Surface Ink Print):
***FT E164061 (UL) 18AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
18/2 Stranded CMP – Beige
Click to
Return to
Index Page
TRI-182STRCMPFT61MBXBEI (1000’)
PRODUCT FEATURES:
DESCRIPTION:
18/2 Stranded CMP
CONSTRUCTION:
This cable consists of two bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
Class 2 General Purpose Power Limited Circuit Cable and Communication Cable
for Plenum Applications.
CONSTRUCTION PARAMETERS:
Conductor
18 AWG bare copper
Stranding
7/26
Insulation Material
Low Smoke PVC
Nominal Insulation Thickness
0.008”
Insulated Conductor Diameter
0.065”
Number of Conductors
2
Nominal Lay Length
4.5”
Jacket Material
Low Smoke PVC
Jacket Thickness
0.015”
Nominal Overall Cable Diameter
0.165”
Approximate Cable Weight (lbs./1000ft)
25
Flame Rating
UL 910 Steiner Tunnel Smoke and Flame Test
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
6.43 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
33 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black, Red
Jacket Colors
Beige
Legend (Surface Ink Print):
***FT E164061 (UL) 18AWG TYPE CMP DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
18/4 Stranded CM – Gray
Click to
Return to
Index Page
TRI-184STRFT45CBXGRY (500’ Gray)
PRODUCT FEATURES:
DESCRIPTION:
18/4 Stranded CM
CONSTRUCTION:
This cable consists of four bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
Class 3 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
18 AWG bare copper
Stranding
7/26
Insulation Material
PVC
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.068”
Number of Conductors
4
Nominal Lay Length
5.0”
Jacket Material
PVC
Jacket Thickness
0.020”
Nominal Overall Cable Diameter
0.205”
Approximate Cable Weight (lbs./1000ft)
33
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
6.43 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
35 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black, Red, White and Green
Jacket Colors
Gray
Legend (Surface Ink Print):
***FT E164061 (UL) 18AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/2 Solid CM – White
Click to
Return to
Index Page
TRI-222SLD1MBXWH (1000’ White-Box)
TRI-222SLD5CBGWH (500’ White-Bag)
PRODUCT FEATURES:
DESCRIPTION:
22/2 Solid CM
CONSTRUCTION:
This cable consists of two bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and UL 444, NEC Articles 725 and 800.
APPLICATION:
Class 2 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG bare copper
Stranding
Solid
Insulation Material
PE
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.038”
Number of Conductors
2
Nominal Lay Length
Parallel
Jacket Material
PVC
Jacket Thickness
0.015”
Nominal Overall Cable Diameter
0.105”
Approximate Cable Weight (lbs./1000ft)
9
Flame Rating
UL 1581 vertical tray flame test
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
30 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black and Red
Jacket Colors
White
Legend (Surface Ink Print):
***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
TRI-222SLD1MBXWH (Box) / TRI-222SLD5CBGWH (Bag)
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/2 Stranded CM – 1000ft
Click to
Return to
Index Page
TRI-222STR1MBXWH (1,000’)
PRODUCT FEATURES:
DESCRIPTION:
22/2 Stranded CM
CONSTRUCTION:
This cable consists of two bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and UL 444, NEC Articles 725 and 800.
APPLICATION:
Class 2 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG bare copper
Stranding
7/30
Insulation Material
PE
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.046”
Number of Conductors
2
Nominal Lay Length
Parallel
Jacket Material
PVC
Jacket Thickness
0.015”
Nominal Overall Cable Diameter
0.120”
Approximate Cable Weight (lbs./1000ft.)
9
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
32 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black and Red.
Jacket Colors
WH = White
Legend (Surface Ink Print):
***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/2 Stranded CM – 500ft
Click to
Return to
Index Page
TRI-222STR5CRLWH(White) TRI-222STR5CRLBL(Black)
TRI-222STR5CRLGRN(Green) TRI-222STR5CRLOR(Orange)
TRI-222STR5CRLYL(Yellow)
PRODUCT FEATURES:
DESCRIPTION:
18/2 Stranded CM
CONSTRUCTION:
This cable consists of two bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and UL 444, NEC Articles 725 and 800.
APPLICATION:
Class 2 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG bare copper
Stranding
7/30
Insulation Material
PE
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.046”
Number of Conductors
2
Nominal Lay Length
Parallel
Jacket Material
PVC
Jacket Thickness
0.015”
Nominal Overall Cable Diameter
0.120”
Approximate Cable Weight (lbs./1000ft.)
9
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
32 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Jacket Colors
Black and Red.
WH = White / BL = Black / GRN = Green / OR = Orange / YL = Yellow
Legend (Surface Ink Print):
***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Coil
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/4 Solid CM – White
Click to
Return to
Index Page
TRI-224SLD1MBXWH (1000’-White)
TRI-224SLD5CBXWH (500’ White)
PRODUCT FEATURES:
DESCRIPTION:
22/4 Solid CM
CONSTRUCTION:
This cable consists of two bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
Class 2 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG bare copper
Stranding
Solid
Insulation Material
PE
Nominal Insulation Thickness
0.008”
Insulated Conductor Diameter
0.043”
Number of Conductors
4
Nominal Lay Length
4.5”
Jacket Material
PVC
Jacket Thickness
0.015”
Nominal Overall Cable Diameter
0.140”
Approximate Cable Weight (lbs./1000ft)
14
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
30 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black, Red, White and Green
Jacket Colors
White
Legend (Surface Ink Print):
***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/4 Solid CM – 500ft – Beige
Click to
Return to
Index Page
TRI-224SLD5CRLBG (Beige) TRI-224SLD5CRLBR(Brown)
TRI-224SLD5CRLGN (Green) TRI-224SLD5CRLGR(Gray)
TRI-224SLD5CRLOR(Orange)TRI-224SLD5CRLYE(Yellow)
PRODUCT FEATURES:
DESCRIPTION:
22/4 Solid CM
CONSTRUCTION:
This cable consists of four bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
Class 2 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG bare copper
Stranding
Solid
Insulation Material
PE
Nominal Insulation Thickness
0.008”
Insulated Conductor Diameter
0.043”
Number of Conductors
4
Nominal Lay Length
4.5”
Jacket Material
PVC
Jacket Thickness
0.015”
Nominal Overall Cable Diameter
0.140”
Approximate Cable Weight (lbs./1000ft.)
14
Flame Rating
UL 1581 vertical tray flame test
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
30 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Jacket Colors
Black, Red, White and Green.
BG = Beige / BR = Brown / GN = Green / GR = Gray / OR = Orange / WH = White / YE = Yellow
Legend (Surface Ink Print):
***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Coil
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/4 Solid FPLR Cable – Red
Click to
Return to
Index Page
TRI-224SLDFPLRFT45CRLRD (500’ Coil)
TRI-224SLDFPLRFT41MBXRD (1000’ Box)
PRODUCT FEATURES:
DESCRIPTION:
22/4 Solid FPLR Cable
CONSTRUCTION:
This cable consists of four bare copper insulated conductors and an overall jacket.
APPROVALS:
UL Standard 1424 and 444, NEC Articles 760 and 800.
APPLICATION:
Power Limited Fire Alarm Circuit Cable and Communication Cable.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG bare copper
Stranding
Solid
Insulation Material
PVE
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.045”
Number of Conductors
4
Nominal Lay Length
4.5”
Jacket Material
PVC
Jacket Thickness
0.020”
Nominal Overall Cable Diameter
0.155”
Approximate Cable Weight (lbs./1000ft)
20
Flame Rating
UL 1581 vertical tray flame test
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20°
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
30 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Red, Black, Yellow and Blue
Jacket Colors
Red
Legend (Surface Ink Print):
***FT E164182 (UL) 22AWG TYPE FPLR DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Packaging:
Yes - For Easy Jacket Removal
TRI-224SLDFPLRFT41MBXRD (1000’ Box) TRI-224SLDFPLRFT45CRLRD (500’ Coil)
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/4 Stranded CM – White
Click to
Return to
Index Page
TRI-224STR1MBXWH (1000’ White)
TRI-224STR5CBXWH (500’ White)
PRODUCT FEATURES:
DESCRIPTION:
22/4 Solid CM
CONSTRUCTION:
This cable consists of four bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
Class 2 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG bare copper
Stranding
7/30
Insulation Material
PE
Nominal Insulation Thickness
0.009”
Insulated Conductor Diameter
0.047”
Number of Conductors
4
Nominal Lay Length
4.5”
Jacket Material
PVC
Jacket Thickness
0.015”
Nominal Overall Cable Diameter
0.150”
Approximate Cable Weight (lbs./1000ft)
15
Flame Rating
UL 1581 vertical tray flame test
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
32 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black, Red, White and Green
Jacket Colors
White
Legend (Surface Ink Print):
***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/4 STRANDED CM – 500ft
Click to
Return to
Index Page
TRI-224STR5CRLWH (White) TRI-224STR5CRLBG(Beige)
TRI-224STR5CRLBR (Brown) TRI-224STR5CRLYL(Yellow)
PRODUCT FEATURES:
DESCRIPTION:
22/4 Stranded CM
CONSTRUCTION:
This cable consists of four bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
Class 2 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG bare copper
Stranding
7/30
Insulation Material
PE
Nominal Insulation Thickness
0.009”
Insulated Conductor Diameter
0.047”
Number of Conductors
4
Nominal Lay Length
4.5”
Jacket Material
PVC
Jacket Thickness
0.015”
Nominal Overall Cable Diameter
0.150”
Approximate Cable Weight (lbs./1000ft.)
15
Flame Rating
UL 1581 vertical tray flame test
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
32 pF/ft. Nominal
Operating Voltage
300 V RMS max
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Black, Red, White and Green
Jacket Colors
WH = White / BG = Beige / BR = Brown / YL = Yellow
Legend (Surface Ink Print):
***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Coil
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/4 Stranded CMP – White
Click to
Return to
Index Page
TRI-224STRCMPFT61MBXWH (1000’)
PRODUCT FEATURES:
DESCRIPTION:
22/4 Stranded CMP
CONSTRUCTION:
This cable consists of four tinned copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
Class 2 General Purpose Power Limited Circuit Cable and Communication Cable
for Plenum Applications.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG tinned copper
Stranding
7/30
Insulation Material
Low Smoke PVC
Nominal Insulation Thickness
0.008”
Insulated Conductor Diameter
0.045”
Number of Conductors
4
Nominal Lay Length
4.5”
Jacket Material
Low Smoke PVC
Jacket Thickness
0.015”
Nominal Overall Cable Diameter
0.138”
Approximate Cable Weight (lbs./1000ft)
15
Flame Rating
UL 910 Steiner Tunnel Smoke and Flame Test
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
25 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Red, Black, White and Green
Jacket Colors
White
Legend (Surface Ink Print):
***FT E164061 (UL) 22AWG TYPE CMP DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/6 Stranded Shielded CM Cable – Gray
Click to
Return to
Index Page
TRI-226STRSHLDFT4BXGRY (500’)
PRODUCT FEATURES:
DESCRIPTION:
22/6 Stranded FPL Cable
CONSTRUCTION:
This cable consists of six bare copper insulated conductors with an overall shield with a drain.
The overall assembly has an overall jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
Power Limited Fire Alarm Circuit Cable and Communication Cable for Riser Applications.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG bare copper
Stranding
7/30
Insulation Material
PVC
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.050”
Number of Conductors
6
Nominal Lay Length
4.0”
Shield Material
Aluminum/Mylar
Drain Wire
22 AWG 7/30 tinned copper
Jacket Material
PVC
Jacket Thickness
0.020”
Nominal Overall Cable Diameter
0.187”
Approximate Cable Weight (lbs./1000ft)
27
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
35 pF/ft. Nominal
Capacitance Between Conductors to Shield@ 1 KHz
63 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Red, Black, White, Green, Yellow and Blue
Jacket Colors
Gray
Legend (Surface Ink Print):
***FT E164061 (UL) 22AWG TYPE CM OR CL3 DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/6 Stranded CM / CL3 – Gray
Click to
Return to
Index Page
TRI-226STRSIG5CGRY (500’)
PRODUCT FEATURES:
DESCRIPTION:
22/6 Stranded CM / CL3
CONSTRUCTION:
This cable consists of six bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
Class 2 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG bare copper
Stranding
7/30
Insulation Material
PVC
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.050”
Number of Conductors
6
Nominal Lay Length
5.5”
Jacket Material
PVC
Jacket Thickness
0.015”
Nominal Overall Cable Diameter
0.180”
Approximate Cable Weight (lbs./1000ft)
24
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
32 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Insulation Colors
Red, Black, White, Green, Yellow and Blue
Jacket Colors
Gray
Legend (Surface Ink Print):
***FT E164061 (UL) 22AWG TYPE CM DEVICE A B C D E F ZONE 0 1 2 3 4 5 6 7 8 9
Ripcord
Yes - For Easy Jacket Removal
Packaging
Box
Connectivity
•
Security
•
Solutions
For orders, please call 888.874.3336 (Branch sales) or 800.366.4472 (Technical Sales) | Visit us on the web at www.tri-ed.com
MULTI CONDUCTOR CABLES:
22/12 Stranded CM – Gray
Click to
Return to
Index Page
TRI-2212STR5CBXGRY (1000’)
PRODUCT FEATURES:
DESCRIPTION:
22/12 Stranded CMP
CONSTRUCTION:
This cable consists of 12 bare copper insulated conductors with an overall extruded jacket.
APPROVALS:
UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION:
Class 2 General Purpose Power Limited Circuit Cable and Communications Cable.
CONSTRUCTION PARAMETERS:
Conductor
22 AWG bare copper
Stranding
7/30
Insulation Material
PVC
Nominal Insulation Thickness
0.010”
Insulated Conductor Diameter
0.047”
Number of Conductors
12
Nominal Lay Length
6.0”
Jacket Material
PVC
Jacket Thickness
0.018”
Nominal Overall Cable Diameter
0.220”
Approximate Cable Weight (lbs./1000ft)
43
Flame Rating
UL 1581 vertical tray flame test.
ELECTRICAL PROPERTIES:
Nominal DC Resistance per Conductor @ 20° C
16.19 Ohms/1000ft. Nominal
Capacitance Between Conductors @ 1 KHz
32 pF/ft. Nominal
Operating Voltage
300 V RMS max.
Temperature Rating
-20° to 60° C
JACKET:
Red, Black, White, Green, Brown, Blue,
Orange, Yellow, Purple, Gray, Pink and Beige
Insulation Colors
Jacket Colors