EVA A6 20W LED underwater light

advertisement
Installation Instructions|
A6 & A12 Mono/RGBW underwaterlight
EVA-A12-XX
EVA-A6-XX
IMPORTANT SAFETY INSTRUCTIONS. READ AND FOLLOW
ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS
Index
1. Safety and installation instructions..............................................................4
2. Chart of parts...............................................................................................5
3. Mounting instructions..................................................................................7
3.1 Mounting Instructions Surface mounting............................................8
3.2 Mounting Instructions Polyester/Liner Pools.......................................9
3.3 Mounting Instructions Concrete Pools...............................................10
3.4 Mounting Instructions Myrtha Pools ................................................11
4. Electrical Installation Instructions...............................................................12
4.1 Electrical Installation Instructions Mono Driver A-6..........................13
4.2 Electrical Installation Instructions Mono Driver A-12.........................15
4.3 Electrical Installation Instructions RGBW driver.................................17
5. Wiring Diagram...........................................................................................18
5.1 Wiring diagram Architech EVO DMX Control.....................................18
5.2 Wiring diagram RGBW Remote control..............................................19
5.3 Wiring diagram Dimming Pack...........................................................20
6. Extra information.......................................................................................21
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
3
1. Safety & Installation Instructions| Underwater Light A6/A12
1.
2.
3.
4.
5.
6.
SUBMERGE BEFORE OPERATING LIGHT
RISK OF ELECTRIC SHOCK OR INJURY
WARNING - NEVER ATTEMPT TO OPEN
FIXTURE.
Serious and permanent damage may
occur to the unit if light is not
submerged during operation
This underwater light must be installed
by a certified electrician in accordance
with applicable local rules and regulations. Improper installation may cause
electrical hazards, which may cause
serious or fatal injury to pool users or
property damage.
There are no serviceable parts in the fixture and any attempt to open the valve
can cause permanent and irreparable
damage. Any form of guarantee expires
immediately upon any attempt to open
the fixture.
Follow the instructions in this guide carefully. For questions or queries, please contact your
distributor / reseller or visit www.evaoptic.com.
This lighting system must be installed by a certified electrician in accordance with applicable local
rules and regulations. Improper installation can cause electrical hazards.
Switch off all relevant live electrical wiring before starting the installation.
Please retain these instructions for the user.
EVA Optic BV warrants its products to be free from defects in material and / or workmanship, under
normal conditions, operation and maintenance for a period of two (2) years from the original
invoice date for LED luminaires and two (2) years for drivers / power supplies and electrical
components. Visit www.evaoptic.com for datasheets and our full warranty.
Technical specifications (download the full datasheet on www.evaoptic.com):
Type luminaire
Type of water
Cooling
Max. water temperature
Max. installation depth
Max. Cable length
A6
IP68/IPX8
Fresh water, chlorinated water
Water cooling (Only use in water)
50°C
25 m
100 m (5x4mm²)
A12
IP68/IPX8
Fresh water, chlorinated water
Water cooling (Only use in water)
40°C
25 m
100 m (5x4mm²)
Use of materials
1.
Please check the delivery before assembly for accuracy and completeness. Also adhere to
numbering of parts in project deliveries.
2.
Note that any used materials meet the requirements and guidelines that apply to your specific
application.
3.
Use only the EVA Optic gaskets / bolts / screws / nuts.
4.
Use only original EVA Optic mounting accessories. Warranty will expire irrevocably when using
other materials.
5.
When indicated in the installation manual, always use the supplied EPDM rings to prevent strain on
the luminaire.
4
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
2. Chart of parts| Niche A6 & A12
EVA-A6-XX | EVA-A12-XX
No
Part description
Part No.
Quantity
1
A6 underwater luminaire
ULA6
1
2
A12 underwater luminaire ULA12
1
3
DIN 7991 M5X20
UL03
3
4
Bolt M3
UL04
3
5
EPDM rubber
UL05
3
3
4
1/2
5
EVA-AA-30| for surface mounting
No. Part description
Part No.
Quantity
6
SS316 Backside
AA-S1
1X
7
Rubber ring
AA-S2
1X
8
Rubber ring small
AA-S3
1X
9
Iron ring
AA-S4
1X
10
SS316 Lock nut
AA-S5
1X
11
Cable gland
AA-S6
1X
12
Washer
AA-S7
1X
13
Seal
AA-S8
1X
EVA-AA-35
1X
99* Extension kit
for 6-40cm wall thickness
(prod. not shown)
10
8
7
6
12
13
11
9
* Extension kit for surface mounting. Sold separately.
EVA-AA-10| Installation Housing ABS for concrete pools
No
Part description
Part No.
Quantity
14
Installation Housing
AA-C1
1X
15
Plastic M6X25
AA-C2
4X
16
Cable gland
AA-C3
1X
17
Washer
AA-C4
1X
18
Seal
AA-C5
1X
19
Hose
AA-C6
1X
20
Hose barb
AA-C7
1X
14
16
20
17
18
15
19
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
5
2. Chart of parts| Niche A6 & A12
EVA-AA-09| Installation Housing ABS for poly pools
No. Part description
Part No.
Quantity
21
Installation housing
AA-P1
1X
22
23
24
25
26
27
Rubber ring 2mm
Ring 3mm
Cover ring
Cable-gland
Washer
Seal
AA-P2
AA-P3
AA-P4
AA-P5
AA-P6
AA-P7
1X
1X
1X
1X
1X
1X
28
29
30
Hose barb
Hose
M5x25
AA-P8
AA-P9
AA-P10
1X
1X
6X
22
28
25
23
21
27
26
29
24
30
EVA-AA-13| SS316 Installation housing for Myrtha Pools
No. Part description
Part No.
Quantity
31
316SS Niche
AA-M1
1X
32
Luminaire attachment
AA-M2
2X
33
Sealing ring
AA-M3
3X
34
Cover ring
AA-M4
1X
35
Cable-gland NPT 1/2
AA-M5
2X
36
Washer
AA-M6
2X
37
Seal
AA-M7
2X
38
DIN 7991 M5X25
AA-M8
3X
39
Bolt M5
AA-M9
9X
40
Fender washer
AA-M10
9X
31
32
EVA-AA-11/12| EVA Cover plates
No. Part description
Size
Part No.
Quantity
41
Cover plate RVS 316 For
EVA niche in concrete pools
ø 194 mm
AA-D1
1X
41
Cover plate RVS 316 For
EVA niche in Polyester/Liner
and replacement PAR56
ø 174 mm
AA-D2
1X
Cover plate RVS 316
ø 265 mm hole distance
169mm
AA-D3
1x
Cover plate RVS 316
ø 265 mm hole distance
234mm
AA-D4
1x
Cover plate RVS 316
ø 269,5 mm hole distance
254mm
AA-D5
1x
Cover plate RVS 316
ø 227 mm hole distance
213,5mm
AA-D6
1x
AA-D7
2X
41
41
41
41
42
6
For replacement Wibre
For replacement Bega
For replacement Astral
For replacement MTS
M4X50
34
33
35
37
38
36
39
40
41 - EVA cover plates:
EVA-AA-11
EVA-AA-21
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
EVA-AA-20
EVA-AA-12
EVA-AA-23
EVA-AA-22
42
3. Mounting instructions| Underwater Light A6 & A12
Mounting of underwater light
1.
2.
3.
4.
5.
6.
7.
Install underwater luminaire on a flat, level surface. There should be no tension on the
luminaire or cover plate.
Keep at least 5 cm of free space behind the lamp for effective water cooling.
The front of the underwater lights should always be free of obstacles. By
placing movable bottom, play objects or other obstacles immediately in front of
the luminaire, the luminaire does not get enough cooling
Tighten bolts / nuts not tighter than finger-tight.
Always immerse the fittings before use to avoid serious and permanent damage
to the fixture.
Never clean the lamp with concentrated detergents
Never attempt to open the luminaire. There are no user replaceable parts in the fixture
and any attempt to open the fixture will lead to permanent and irreversible damage.
Warranty expires immediately after any attempt to open the fixture.
3.1 Mounting instructions surface mounting, go to page 8
Required products:
- EVA-A6-XX| Luminaire A6 & power supply box or
- EVA-A12-XX| Luminaire A12 & power supply box
- EVA-AA-30| for surface mounting set
- EVA-AA-35| Extension kit for surface mounting
3.2 Mounting instructions concrete pools, go to page 9
Required products:
- EVA-A6-XX| Luminaire A6 & power supply box or
- EVA-A12-XX| Luminaire A12 & power supply box
- EVA-AA-10| Installation Housing ABS for concrete pools
- EVA-AA-11| Stainless steel cover plate for concrete pools
3.3 Mounting instructions polyester, go to page 10
Required products:
- EVA-A6-XX| Luminaire A6 & power supply box or
- EVA-A12-XX| Luminaire A12 & power supply box
- EVA-AA-09| Installation Housing ABS for polyester/liner pools
- EVA-AA-11/12| Stainless steel cover plate for polyester pools
3.4 Mounting instructions Myrtha, go to page 11
Required products:
- EVA-A6-XX| Luminaire A6 & power supply box or
- EVA-A12-XX| Luminaire A12 & power supply box
- EVA-AA-13| SS316 Installation housing for Myrtha Pools
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
7
3.1 Mounting instructions surface mounting| Underwater Light A6 & A12
9
11
12
13
8
7
10
1/2
6
4
5
13
Assembly Cable gland
Polyester/Liner
Extension kit for mounting
Polyester/Liner
99
Concrete
40 mm
Swivel M25 X1,5
Min. 60 mm
Max. 400 mm
8
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
3.2 Mounting instructions Concrete pools| Underwater Light A6 & A12
Assambly
Cable-gland
17
40
1/2
19
20
4
41
3
5
18
17
16
14
Concrete
Concrete
Concrete
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
9
3.3 Mounting instructions Polyester/liner pools| Underwater Light A6/12
22
23
24
30
40
5
41
3
28
26
25
21
26
27
Assembly Cable gland
Polyester/Liner
10
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
4
3.4 Mounting instructions Myrtha pools| Underwater Light A6 & A12
39 34 33
40
35
38
36 35
36
39
32
1/2
38
36
Assembly Cable gland
31
Polyester/Liner
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
11
4. Electrical Installation instructions| Underwater Light Q2
Connecting Power supply unit
PAY ATTENTION! Turn off all relevant live wiring before starting the installation.
1. Always use one power supply per luminaire.
2. Mount the power supply box in a dry, cool area.
3. Allow at least 5 cm of space around the power supply box for efficient
thermal management.
4. Mount the power supply box always with cable glands downwards
5. Electrical connection according to the supplied wiring diagram
- For connecting a A6 Mono driver go to page 13
- For connecting a A12 Mono driver go to page 14
- For connecting a A6/A12 RGBW driver go to page 15
12
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
4.1 Electrical Installation Instructions| Underwater Light A6 Mono
PAY ATTENTION! Turn off all relevant live wiring before starting the installation.
A. Connecting the PSU to AC
Step 1
- Open the PSU and mount the included cable
glands in the pre-drilled holes.
Step 2
- Remove side-covers from the power supply,
with a screwdriver.
Step 3
- Connect the Live wire (AC) with the power supply
- Connect phase (Black) to ACL/DC+ (1th connection)
- Connect Null (Blue) to ACN/DC- (2th connection)
L
N
- Place the blue side caps back on the original position
en screw them back on.
B. Connecting the luminaire
Step 4
- Connect the black wire from the light unit, to the
V- (4th slot) on the driver.
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
13
4.1 Electrical Installation Instructions| Underwater Light A6 Mono
Step 5
- Choose the desired light colour (see images of colour
options below)
- Connect the corresponding wire(s) to V+ (5th slot)
- When using 2 coloured wires, tighten both wires
together before inserting them into the slot
Colour Options:
Light Colour:
White
Connect wire to V+:
White
Light Colour:
Blue
Connect wire to V+:
Blue
Light Colour:
Red
Connect wire to V+:
Red
Light Color:
Green
Connect wire to V+:
Green
Light Colour:
Mediterranean Blue
Connect wire to V+:
Green & Blue
Light Colour:
Sky Blue
Connect wire to V+:
White & Blue
NOTE: only use above colours. Any other combination may harm the luminaire!
Step 6
- After connecting the V- (black wire) and the V+
(coloured wire), cut the remaining unused wires at the
cable base and close the PSU
14
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
4.2 Electrical Installation Instructions| Underwater Light A12 Mono
PAY ATTENTION! Turn off all relevant live wiring before starting the installation.
A. Connecting power (AC)
Step 1
- Open the PSU
- Install cable glands in the pre drilled holes
Step 2
- Connect AC with the input cable of the driver
(connect with Wago connector, see image below)
Power input
(AC)
Power output
(DC)
Connecting Wago
2. Open clamping unit
using lever and insert
conductor
1. Strip the conductor
9-10mm
3. Lower the lever to
close the clamp to
complete the connection
B. Connecting the luminaire
Step 4
- Connect the black wire of the light unit to V- (3) in the 5th
slot.
VEVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
15
4.2 Electrical Installation Instructions| Underwater Light A12 Mono
Step 5
- Choose the desired light colour (see images of colour
options below)
- Connect the corresponding wire(s) to V+ (5th slot)
- When using 2 coloured wires, tighten both wires together
before inserting them into the slot
Step 6
- After connecting the V- (black wire) and V+ (coloured wire),
Cut the remaining unused wires at the cable base.
Colour Options:
Light Colour:
White
Connect wire to V+:
White
Light Colour:
Blue
Connect wire to V+:
Blue
Light Colour:
Red
Connect wire to V+:
Red
Light Colour:
Green
Connect wire to V+:
Green
Light Colour:
Mediterranean Blue
Connect wire to V+:
Green & Blue
Light Colour:
Sky Blue
Connect wire to V+:
White & Blue
NOTE: only use above colours. Any other combination may harm the luminaire!
16
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
4.3 Electrical Installation Instructions| Underwater Light A6/A12 RGBW
PAY ATTENTION! Turn off all relevant live wiring before starting the installation.
Step 1
- Open the PSU
- Install the cable glands in the pre-drilled holes
Step 2
- Connect Live wire with the driver. The most common way is by
connecting with Wago connectors (see page 15).
Step 3
- Connect the Aqua-cable from the lamp to the green PDTA
connector on the blue printed circuit in following order:
CH1= Red
CH2= Green
CH3= Blue
CH4= White
CH5= Black
After successful connecting, place the connector back on the blue
printed circuit
Step 4
- After connecting power input and output, close the power
supply unit.
Input
Output
V+
CH1 Red
CH2 Green
CH3 Blue
CH4 White
GND Black
V-
Blue printed Circuit. Left side is input, right side is output.
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
17
5.1 Wiring Diagram| ArchiTech EVO DMX Control
Important:
For addressing the lights use binary DMX count or use a DIP switch calculator
PoE!
(Power over
Ethernet)
First & Next Drivers
Use EVA
Optic
datacable
(green)
EVA-AA-96
EVA LED Driver
Do not
connect
DMX shield
to ground!
NTC
!
Master
Slave
Data-bus
terminator
1 2 4 8
16
32
64 128 256
ADDRESS
M E
Status S D
Use EVA
Optic
datacable
(green)
EVA-AA-96
Do not
connect
DMX shield
to ground!
!
EVA LED Driver
NTC
Master
Slave
Data-bus
terminator
18
1 2 4 8
16
32
ADDRESS
64 128 256
M E
Status S D
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
5.2 Wiring Diagram| RGBW Remote Control
Use this wiring diagram for connecting drivers to:
- Pulse Switch
- Remote Control
230V
L
Dimming
output
N
First Driver
EVA LED Driver
Use EVA Optic
datacable (green)
EVA-AA-96
Do not connect
DMX shield to
ground!
!
NTC
Master
Slave
Data-bus
terminator
1 2 4 8
16
32
64 128 256
ADDRESS
M E
Status S D
Dimming
output
Next Driver(s)
Use EVA Optic
datacable (green)
EVA-AA-96
EVA LED Driver
Do not connect
DMX shield to
ground!
NTC
!
Master
Slave
Data-bus
terminator
1 2 4 8
16
32
ADDRESS
64 128 256
M E
Status S D
Dimming
output
Use EVA Optic
datacable (green)
EVA-AA-96
Do not connect
DMX shield to
ground!
Last Driver
EVA LED Driver
!
NTC
Master
Slave
Data-bus
terminator
1 2 4 8
16
32
ADDRESS
64 128 256
M E
Status S D
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
19
5.3 Wiring Diagram| Dimming pack (only for mono colour luminaires)
+ - L
Dimming 10% - 100%
EVA Optic
Dimming pack
Wiring Diagram with
dimming pack:
! Maximum 28 Q2/ A6 lights per 1 dimming pack
! Maximum 14 A12 lights per 1 dimming pack
Connect to
100-270 VAC
Dimming
EVA Optic driver
Q2 /A6 /A12
GND (GRN)
1-10V (PUR)
10V (YLW)
Max. 100m
<50m 2X2,5 mm²
50-100m 2x4 mm²
Connect to
Q2/A6/A12
V+ (RED)
V- (BLK)
LED DC output
Connect to to driver
<50m 2X2,5 mm²
50-100m 2x4 mm²
V+ (RED)
V- (BLK)
ACL (BLK)
ACN (WHT)
Dimming
EVA Optic driver
Q2 /A6 /A12
Max. 100m
Connect to
Q2/A6/A12
LED DC output
AC input
GND (GRN)
1-10V (PUR)
10V (YLW)
ACL (BLK)
ACN (WHT)
AC input
Connect to next driver
Dimming 10% - 100% &
On/Off switch
Connect to
100-270 VAC
EVA Optic
Dimming pack
+ - L
Wiring diagram with
dimming pack:
! Maximum 28 Q2/ A6 lights per 1 dimming pack
! Maximum 14 A12 lights per 1 dimming pack
Dimming
EVA Optic driver
Q2 /A6 /A12
EVA Optic driver
Q2 /A6 /A12
LED DC output
Max. 100m
<50m 2X2,5 mm²
50-100m 2x4 mm²
Connect to
Q2/A6/A12
V+ (RED)
V- (BLK)
Connect to next driver
Dimming
<50m 2X2,5 mm²
50-100m 2x4 mm²
Connect to
Q2/A6/A12
GND (GRN)
1-10V (PUR)
10V (YLW)
ACL (BLK)
ACN (WHT)
AC input
Max. 100m
V+ (RED)
V- (BLK)
LED DC output
GND (GRN)
1-10V (PUR)
10V (YLW)
ACL (BLK)
ACN (WHT)
AC input
Connect to next driver
20
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
6. Additional accessories| Underwater Light Q2 RGBW
EVA-AA-78
EVA-AA-77
EVA-AA-76
EVA-AA-75
EVA-AA-74
EVA-AA-73
Accessories DMX & Dimming | for EVA Q2 RGBW and Mono
Product
Description
EVA-AA-78
EVA-AA-77
EVA-AA-76
EVA-AA-75
EVA-AA-74
EVA-AA-73
EVA-AA-96
EVA-AA-98
DMX control ArchiTech EVO
DMX control EVA ArchiTech PRO
DMX control EVA ArchiTech XL
DMX control EVA ArchiTech
Remote control Multicolour
Dimming pack (only for mono colour luminaires)
DMX cable
EVA optic Aquacable RGBW 5X0,5 mm2
For manuals and software for DMX controllers go visit the service page on our website dmx.evaoptic.nl
Contact information:
EVA Optic BV
De Velde 1
NL 8064 PH
ZWARTSLUIS
+31 (0)38-33 75 067
info@evaoptic.com
For product information and warranty, visit our website www.evaoptic.com
EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com
21