Installation Instructions| A6 & A12 Mono/RGBW underwaterlight EVA-A12-XX EVA-A6-XX IMPORTANT SAFETY INSTRUCTIONS. READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS Index 1. Safety and installation instructions..............................................................4 2. Chart of parts...............................................................................................5 3. Mounting instructions..................................................................................7 3.1 Mounting Instructions Surface mounting............................................8 3.2 Mounting Instructions Polyester/Liner Pools.......................................9 3.3 Mounting Instructions Concrete Pools...............................................10 3.4 Mounting Instructions Myrtha Pools ................................................11 4. Electrical Installation Instructions...............................................................12 4.1 Electrical Installation Instructions Mono Driver A-6..........................13 4.2 Electrical Installation Instructions Mono Driver A-12.........................15 4.3 Electrical Installation Instructions RGBW driver.................................17 5. Wiring Diagram...........................................................................................18 5.1 Wiring diagram Architech EVO DMX Control.....................................18 5.2 Wiring diagram RGBW Remote control..............................................19 5.3 Wiring diagram Dimming Pack...........................................................20 6. Extra information.......................................................................................21 EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 3 1. Safety & Installation Instructions| Underwater Light A6/A12 1. 2. 3. 4. 5. 6. SUBMERGE BEFORE OPERATING LIGHT RISK OF ELECTRIC SHOCK OR INJURY WARNING - NEVER ATTEMPT TO OPEN FIXTURE. Serious and permanent damage may occur to the unit if light is not submerged during operation This underwater light must be installed by a certified electrician in accordance with applicable local rules and regulations. Improper installation may cause electrical hazards, which may cause serious or fatal injury to pool users or property damage. There are no serviceable parts in the fixture and any attempt to open the valve can cause permanent and irreparable damage. Any form of guarantee expires immediately upon any attempt to open the fixture. Follow the instructions in this guide carefully. For questions or queries, please contact your distributor / reseller or visit www.evaoptic.com. This lighting system must be installed by a certified electrician in accordance with applicable local rules and regulations. Improper installation can cause electrical hazards. Switch off all relevant live electrical wiring before starting the installation. Please retain these instructions for the user. EVA Optic BV warrants its products to be free from defects in material and / or workmanship, under normal conditions, operation and maintenance for a period of two (2) years from the original invoice date for LED luminaires and two (2) years for drivers / power supplies and electrical components. Visit www.evaoptic.com for datasheets and our full warranty. Technical specifications (download the full datasheet on www.evaoptic.com): Type luminaire Type of water Cooling Max. water temperature Max. installation depth Max. Cable length A6 IP68/IPX8 Fresh water, chlorinated water Water cooling (Only use in water) 50°C 25 m 100 m (5x4mm²) A12 IP68/IPX8 Fresh water, chlorinated water Water cooling (Only use in water) 40°C 25 m 100 m (5x4mm²) Use of materials 1. Please check the delivery before assembly for accuracy and completeness. Also adhere to numbering of parts in project deliveries. 2. Note that any used materials meet the requirements and guidelines that apply to your specific application. 3. Use only the EVA Optic gaskets / bolts / screws / nuts. 4. Use only original EVA Optic mounting accessories. Warranty will expire irrevocably when using other materials. 5. When indicated in the installation manual, always use the supplied EPDM rings to prevent strain on the luminaire. 4 EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 2. Chart of parts| Niche A6 & A12 EVA-A6-XX | EVA-A12-XX No Part description Part No. Quantity 1 A6 underwater luminaire ULA6 1 2 A12 underwater luminaire ULA12 1 3 DIN 7991 M5X20 UL03 3 4 Bolt M3 UL04 3 5 EPDM rubber UL05 3 3 4 1/2 5 EVA-AA-30| for surface mounting No. Part description Part No. Quantity 6 SS316 Backside AA-S1 1X 7 Rubber ring AA-S2 1X 8 Rubber ring small AA-S3 1X 9 Iron ring AA-S4 1X 10 SS316 Lock nut AA-S5 1X 11 Cable gland AA-S6 1X 12 Washer AA-S7 1X 13 Seal AA-S8 1X EVA-AA-35 1X 99* Extension kit for 6-40cm wall thickness (prod. not shown) 10 8 7 6 12 13 11 9 * Extension kit for surface mounting. Sold separately. EVA-AA-10| Installation Housing ABS for concrete pools No Part description Part No. Quantity 14 Installation Housing AA-C1 1X 15 Plastic M6X25 AA-C2 4X 16 Cable gland AA-C3 1X 17 Washer AA-C4 1X 18 Seal AA-C5 1X 19 Hose AA-C6 1X 20 Hose barb AA-C7 1X 14 16 20 17 18 15 19 EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 5 2. Chart of parts| Niche A6 & A12 EVA-AA-09| Installation Housing ABS for poly pools No. Part description Part No. Quantity 21 Installation housing AA-P1 1X 22 23 24 25 26 27 Rubber ring 2mm Ring 3mm Cover ring Cable-gland Washer Seal AA-P2 AA-P3 AA-P4 AA-P5 AA-P6 AA-P7 1X 1X 1X 1X 1X 1X 28 29 30 Hose barb Hose M5x25 AA-P8 AA-P9 AA-P10 1X 1X 6X 22 28 25 23 21 27 26 29 24 30 EVA-AA-13| SS316 Installation housing for Myrtha Pools No. Part description Part No. Quantity 31 316SS Niche AA-M1 1X 32 Luminaire attachment AA-M2 2X 33 Sealing ring AA-M3 3X 34 Cover ring AA-M4 1X 35 Cable-gland NPT 1/2 AA-M5 2X 36 Washer AA-M6 2X 37 Seal AA-M7 2X 38 DIN 7991 M5X25 AA-M8 3X 39 Bolt M5 AA-M9 9X 40 Fender washer AA-M10 9X 31 32 EVA-AA-11/12| EVA Cover plates No. Part description Size Part No. Quantity 41 Cover plate RVS 316 For EVA niche in concrete pools ø 194 mm AA-D1 1X 41 Cover plate RVS 316 For EVA niche in Polyester/Liner and replacement PAR56 ø 174 mm AA-D2 1X Cover plate RVS 316 ø 265 mm hole distance 169mm AA-D3 1x Cover plate RVS 316 ø 265 mm hole distance 234mm AA-D4 1x Cover plate RVS 316 ø 269,5 mm hole distance 254mm AA-D5 1x Cover plate RVS 316 ø 227 mm hole distance 213,5mm AA-D6 1x AA-D7 2X 41 41 41 41 42 6 For replacement Wibre For replacement Bega For replacement Astral For replacement MTS M4X50 34 33 35 37 38 36 39 40 41 - EVA cover plates: EVA-AA-11 EVA-AA-21 EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com EVA-AA-20 EVA-AA-12 EVA-AA-23 EVA-AA-22 42 3. Mounting instructions| Underwater Light A6 & A12 Mounting of underwater light 1. 2. 3. 4. 5. 6. 7. Install underwater luminaire on a flat, level surface. There should be no tension on the luminaire or cover plate. Keep at least 5 cm of free space behind the lamp for effective water cooling. The front of the underwater lights should always be free of obstacles. By placing movable bottom, play objects or other obstacles immediately in front of the luminaire, the luminaire does not get enough cooling Tighten bolts / nuts not tighter than finger-tight. Always immerse the fittings before use to avoid serious and permanent damage to the fixture. Never clean the lamp with concentrated detergents Never attempt to open the luminaire. There are no user replaceable parts in the fixture and any attempt to open the fixture will lead to permanent and irreversible damage. Warranty expires immediately after any attempt to open the fixture. 3.1 Mounting instructions surface mounting, go to page 8 Required products: - EVA-A6-XX| Luminaire A6 & power supply box or - EVA-A12-XX| Luminaire A12 & power supply box - EVA-AA-30| for surface mounting set - EVA-AA-35| Extension kit for surface mounting 3.2 Mounting instructions concrete pools, go to page 9 Required products: - EVA-A6-XX| Luminaire A6 & power supply box or - EVA-A12-XX| Luminaire A12 & power supply box - EVA-AA-10| Installation Housing ABS for concrete pools - EVA-AA-11| Stainless steel cover plate for concrete pools 3.3 Mounting instructions polyester, go to page 10 Required products: - EVA-A6-XX| Luminaire A6 & power supply box or - EVA-A12-XX| Luminaire A12 & power supply box - EVA-AA-09| Installation Housing ABS for polyester/liner pools - EVA-AA-11/12| Stainless steel cover plate for polyester pools 3.4 Mounting instructions Myrtha, go to page 11 Required products: - EVA-A6-XX| Luminaire A6 & power supply box or - EVA-A12-XX| Luminaire A12 & power supply box - EVA-AA-13| SS316 Installation housing for Myrtha Pools EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 7 3.1 Mounting instructions surface mounting| Underwater Light A6 & A12 9 11 12 13 8 7 10 1/2 6 4 5 13 Assembly Cable gland Polyester/Liner Extension kit for mounting Polyester/Liner 99 Concrete 40 mm Swivel M25 X1,5 Min. 60 mm Max. 400 mm 8 EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 3.2 Mounting instructions Concrete pools| Underwater Light A6 & A12 Assambly Cable-gland 17 40 1/2 19 20 4 41 3 5 18 17 16 14 Concrete Concrete Concrete EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 9 3.3 Mounting instructions Polyester/liner pools| Underwater Light A6/12 22 23 24 30 40 5 41 3 28 26 25 21 26 27 Assembly Cable gland Polyester/Liner 10 EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 4 3.4 Mounting instructions Myrtha pools| Underwater Light A6 & A12 39 34 33 40 35 38 36 35 36 39 32 1/2 38 36 Assembly Cable gland 31 Polyester/Liner EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 11 4. Electrical Installation instructions| Underwater Light Q2 Connecting Power supply unit PAY ATTENTION! Turn off all relevant live wiring before starting the installation. 1. Always use one power supply per luminaire. 2. Mount the power supply box in a dry, cool area. 3. Allow at least 5 cm of space around the power supply box for efficient thermal management. 4. Mount the power supply box always with cable glands downwards 5. Electrical connection according to the supplied wiring diagram - For connecting a A6 Mono driver go to page 13 - For connecting a A12 Mono driver go to page 14 - For connecting a A6/A12 RGBW driver go to page 15 12 EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 4.1 Electrical Installation Instructions| Underwater Light A6 Mono PAY ATTENTION! Turn off all relevant live wiring before starting the installation. A. Connecting the PSU to AC Step 1 - Open the PSU and mount the included cable glands in the pre-drilled holes. Step 2 - Remove side-covers from the power supply, with a screwdriver. Step 3 - Connect the Live wire (AC) with the power supply - Connect phase (Black) to ACL/DC+ (1th connection) - Connect Null (Blue) to ACN/DC- (2th connection) L N - Place the blue side caps back on the original position en screw them back on. B. Connecting the luminaire Step 4 - Connect the black wire from the light unit, to the V- (4th slot) on the driver. EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 13 4.1 Electrical Installation Instructions| Underwater Light A6 Mono Step 5 - Choose the desired light colour (see images of colour options below) - Connect the corresponding wire(s) to V+ (5th slot) - When using 2 coloured wires, tighten both wires together before inserting them into the slot Colour Options: Light Colour: White Connect wire to V+: White Light Colour: Blue Connect wire to V+: Blue Light Colour: Red Connect wire to V+: Red Light Color: Green Connect wire to V+: Green Light Colour: Mediterranean Blue Connect wire to V+: Green & Blue Light Colour: Sky Blue Connect wire to V+: White & Blue NOTE: only use above colours. Any other combination may harm the luminaire! Step 6 - After connecting the V- (black wire) and the V+ (coloured wire), cut the remaining unused wires at the cable base and close the PSU 14 EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 4.2 Electrical Installation Instructions| Underwater Light A12 Mono PAY ATTENTION! Turn off all relevant live wiring before starting the installation. A. Connecting power (AC) Step 1 - Open the PSU - Install cable glands in the pre drilled holes Step 2 - Connect AC with the input cable of the driver (connect with Wago connector, see image below) Power input (AC) Power output (DC) Connecting Wago 2. Open clamping unit using lever and insert conductor 1. Strip the conductor 9-10mm 3. Lower the lever to close the clamp to complete the connection B. Connecting the luminaire Step 4 - Connect the black wire of the light unit to V- (3) in the 5th slot. VEVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 15 4.2 Electrical Installation Instructions| Underwater Light A12 Mono Step 5 - Choose the desired light colour (see images of colour options below) - Connect the corresponding wire(s) to V+ (5th slot) - When using 2 coloured wires, tighten both wires together before inserting them into the slot Step 6 - After connecting the V- (black wire) and V+ (coloured wire), Cut the remaining unused wires at the cable base. Colour Options: Light Colour: White Connect wire to V+: White Light Colour: Blue Connect wire to V+: Blue Light Colour: Red Connect wire to V+: Red Light Colour: Green Connect wire to V+: Green Light Colour: Mediterranean Blue Connect wire to V+: Green & Blue Light Colour: Sky Blue Connect wire to V+: White & Blue NOTE: only use above colours. Any other combination may harm the luminaire! 16 EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 4.3 Electrical Installation Instructions| Underwater Light A6/A12 RGBW PAY ATTENTION! Turn off all relevant live wiring before starting the installation. Step 1 - Open the PSU - Install the cable glands in the pre-drilled holes Step 2 - Connect Live wire with the driver. The most common way is by connecting with Wago connectors (see page 15). Step 3 - Connect the Aqua-cable from the lamp to the green PDTA connector on the blue printed circuit in following order: CH1= Red CH2= Green CH3= Blue CH4= White CH5= Black After successful connecting, place the connector back on the blue printed circuit Step 4 - After connecting power input and output, close the power supply unit. Input Output V+ CH1 Red CH2 Green CH3 Blue CH4 White GND Black V- Blue printed Circuit. Left side is input, right side is output. EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 17 5.1 Wiring Diagram| ArchiTech EVO DMX Control Important: For addressing the lights use binary DMX count or use a DIP switch calculator PoE! (Power over Ethernet) First & Next Drivers Use EVA Optic datacable (green) EVA-AA-96 EVA LED Driver Do not connect DMX shield to ground! NTC ! Master Slave Data-bus terminator 1 2 4 8 16 32 64 128 256 ADDRESS M E Status S D Use EVA Optic datacable (green) EVA-AA-96 Do not connect DMX shield to ground! ! EVA LED Driver NTC Master Slave Data-bus terminator 18 1 2 4 8 16 32 ADDRESS 64 128 256 M E Status S D EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 5.2 Wiring Diagram| RGBW Remote Control Use this wiring diagram for connecting drivers to: - Pulse Switch - Remote Control 230V L Dimming output N First Driver EVA LED Driver Use EVA Optic datacable (green) EVA-AA-96 Do not connect DMX shield to ground! ! NTC Master Slave Data-bus terminator 1 2 4 8 16 32 64 128 256 ADDRESS M E Status S D Dimming output Next Driver(s) Use EVA Optic datacable (green) EVA-AA-96 EVA LED Driver Do not connect DMX shield to ground! NTC ! Master Slave Data-bus terminator 1 2 4 8 16 32 ADDRESS 64 128 256 M E Status S D Dimming output Use EVA Optic datacable (green) EVA-AA-96 Do not connect DMX shield to ground! Last Driver EVA LED Driver ! NTC Master Slave Data-bus terminator 1 2 4 8 16 32 ADDRESS 64 128 256 M E Status S D EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 19 5.3 Wiring Diagram| Dimming pack (only for mono colour luminaires) + - L Dimming 10% - 100% EVA Optic Dimming pack Wiring Diagram with dimming pack: ! Maximum 28 Q2/ A6 lights per 1 dimming pack ! Maximum 14 A12 lights per 1 dimming pack Connect to 100-270 VAC Dimming EVA Optic driver Q2 /A6 /A12 GND (GRN) 1-10V (PUR) 10V (YLW) Max. 100m <50m 2X2,5 mm² 50-100m 2x4 mm² Connect to Q2/A6/A12 V+ (RED) V- (BLK) LED DC output Connect to to driver <50m 2X2,5 mm² 50-100m 2x4 mm² V+ (RED) V- (BLK) ACL (BLK) ACN (WHT) Dimming EVA Optic driver Q2 /A6 /A12 Max. 100m Connect to Q2/A6/A12 LED DC output AC input GND (GRN) 1-10V (PUR) 10V (YLW) ACL (BLK) ACN (WHT) AC input Connect to next driver Dimming 10% - 100% & On/Off switch Connect to 100-270 VAC EVA Optic Dimming pack + - L Wiring diagram with dimming pack: ! Maximum 28 Q2/ A6 lights per 1 dimming pack ! Maximum 14 A12 lights per 1 dimming pack Dimming EVA Optic driver Q2 /A6 /A12 EVA Optic driver Q2 /A6 /A12 LED DC output Max. 100m <50m 2X2,5 mm² 50-100m 2x4 mm² Connect to Q2/A6/A12 V+ (RED) V- (BLK) Connect to next driver Dimming <50m 2X2,5 mm² 50-100m 2x4 mm² Connect to Q2/A6/A12 GND (GRN) 1-10V (PUR) 10V (YLW) ACL (BLK) ACN (WHT) AC input Max. 100m V+ (RED) V- (BLK) LED DC output GND (GRN) 1-10V (PUR) 10V (YLW) ACL (BLK) ACN (WHT) AC input Connect to next driver 20 EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 6. Additional accessories| Underwater Light Q2 RGBW EVA-AA-78 EVA-AA-77 EVA-AA-76 EVA-AA-75 EVA-AA-74 EVA-AA-73 Accessories DMX & Dimming | for EVA Q2 RGBW and Mono Product Description EVA-AA-78 EVA-AA-77 EVA-AA-76 EVA-AA-75 EVA-AA-74 EVA-AA-73 EVA-AA-96 EVA-AA-98 DMX control ArchiTech EVO DMX control EVA ArchiTech PRO DMX control EVA ArchiTech XL DMX control EVA ArchiTech Remote control Multicolour Dimming pack (only for mono colour luminaires) DMX cable EVA optic Aquacable RGBW 5X0,5 mm2 For manuals and software for DMX controllers go visit the service page on our website dmx.evaoptic.nl Contact information: EVA Optic BV De Velde 1 NL 8064 PH ZWARTSLUIS +31 (0)38-33 75 067 info@evaoptic.com For product information and warranty, visit our website www.evaoptic.com EVA Optic B.V. | www.evaoptic.com | info@evaoptic.com 21