EXTERNAL METAL LINER
INTERNAL METAL LINER
FACTORY APPLIED
WEATHER SEAL FACTORY APPLIED
WEATHER SEAL
System
INSULATED WALL PANEL (VERTICAL)
Detail
IWP MICROLINE DIMENSIONS
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Drawing No.
RL IWP.V-01
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com
EXTERNAL METAL LINER
INTERNAL METAL LINER
FACTORY APPLIED
WEATHER SEAL
FACTORY APPLIED
WEATHER SEAL
System
INSULATED WALL PANEL (VERTICAL)
Detail
IWP STANDARD
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Drawing No.
RL IWP.V-02
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com
EXTERNAL METAL LINER
INTERNAL METAL LINER
FACTORY APPLIED
WEATHER SEAL
FACTORY APPLIED
WEATHER SEAL
System
INSULATED WALL PANEL (VERTICAL)
Detail
IWP FLAT
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Drawing No.
RL IWP.V-03
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com
FACTORY APPLIED
WEATHER SEAL
EXTERNAL METAL LINER
INTERNAL METAL LINER
FACTORY APPLIED
WEATHER SEAL
System
INSULATED WALL PANEL (VERTICAL)
Detail
IWP PLANK
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Drawing No.
RL IWP.V-04
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com
VERTICAL PANEL JOINT & FASTENER LOCATIONS
DIRECTION OF
PREVAILING WIND
DIRECTION OF
INSTALLATION
CONCEALED MECHANICAL
FASTENER
PROJECT SPECIFIC CALCULATIONS AS
TO DESIGN WIND SPEEDS
System
INSULATED WALL PANEL (VERTICAL)
Detail
IWP PANEL JOINT AND FASTENER
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Drawing No.
RL IWP.V-05
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com
RL IWP 1150
VERTICALLY INSTALLED
CLOSER FLASHING
WITH CONTINUOUS
BUTYL BACK SEAL
0.55 COLOUR
COATED FLASHING
(ENSURE MATERIAL
COMPATIBILITY WITH
PANEL AND
SUBSTRATE)
CONTINUOUS RUN OF BUTYL
SEALANT
INTERNAL CLOSER FLASHING
CONTINUOUS RUN OF BUTYL
SEALANT
COMPRESSIBLE FOAM SEALING
BLOCK
RL 101 SEALANT ACROSS
JOIN
CLOSER FLASHING
WITH CONTINUOUS
BUTYL BACK SEAL
0.55 COLOUR COATED
FLASHING
RL IWP 1150
VERTICALLY INSTALLED
CONTINUOUS
BUTYL BACK SEAL
GALVANISED STEEL
BASE SUPPORT (CONTINUOUS)
BED BASE SUPPORT ON
2 RUNS OF RL101 SEALANT
COMPRESSIBLE FOAM SEALING
BLOCK
RL 101 SEALANT ACROSS
JOIN
System
INSULATED WALL PANEL (VERTICAL)
Detail
IWP BASE DETAIL
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Drawing No.
RL IWP.V-06
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com
CLOSER FLASHING, BACK
SEALED AND MECHANICALLY
ATTACHED ( ONE SIDE ONLY)
RL IWP 1150 WALL PANEL
VERTICALLY INSTALLED
0.55 COLOUR COATED AZ FLASHING INSTALLED WITH
SUFFICIENT FLASHING OVERLAP. FLASHING TO BE
BACK SEALED AT PANEL JUNCTION AND OVERLAPS
AND MECHANICALLY ATTACHED
INSTALLATION DIRECTION
System
INSULATED WALL PANEL (VERTICAL)
Detail
IWP EXTERNAL CORNER
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Drawing No.
RL IWP.V-07
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com
0.55mm COLOUR COATED AZ FLASHING INSTALLED
WITH SUFFICIENT FLASHING OVERLAP. FLASHING TO
BE BACK SEALED AT PANEL JUNCTION AND OVERLAPS
AND MECHANICALLY ATTACHED
CLOSER FLASHING, BACK
SEALED AND MECHANICALLY
ATTACHED ( ONE SIDE ONLY)
RL IWP 1150 WALL PANEL
INSTALLED VERTICALLY
INSTALLATION DIRECTION
System
INSULATED WALL PANEL (VERTICAL)
Detail
IWP INTERNAL CORNER
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Drawing No.
RL IWP.V-08
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com
PEF ROD WITH RL101 SEALANT
20MM WIDE
PIR BLOCK
0.55mm COLOUR COATED AZ FLASHING INSTALLED
WITH SUFFICIENT FLASHING OVERLAP, MECHANICALLY
ATTACHED AND SEALED.
RL IWP INSTALLED VERTICALLY
BACK SEAL WITH RL101 SEALANT
CLOSER FLASHING TO PANEL END
CONTINUOUS STEEL
BRACKET SUPPORT
0.55mm COLOUR COATED AZ FLASHING
INSTALLED WITH SUFFICIENT FLASHING OVERLAP,
MECHANICALLY ATTACHED AND SEALED.
RL IWP INSTALLED VERTICALLY
PEF ROD WITH RL101 SEALANT
20MM WIDE
PIR BLOCK
BACK SEAL WITH RL101 SEALANT
CLOSER FLASHING TO PANEL END
CONTINUOUS STEEL
BRACKET SUPPORT
System
INSULATED WALL PANEL (VERTICAL)
Detail
IWP JUNCTION WITH CONCRETE WALL (RECESSED)
Drawing No.
RL IWP.V-09
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com
CLOSURE FLASHING TO PANEL END
0.55mm COLOUR COATED AZ FLASHING INSTALLED
WITH SUFFICIENT FLASHING OVERLAP, MECHANICALLY
ATTACHED AND SEALED.
RL IWP INSTALLED VERTICALLY
BACK SEAL WITH RL101 SEALANT
CLOSURE FLASHING TO PANEL END
System
INSULATED WALL PANEL (VERTICAL)
Detail
IWP JUNCTION WITH CONCRETE WALL (EXPRESSED)
Drawing No.
RL IWP.V-10
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com
TYPICAL LAYOUT FOR STRUCTURAL
ATTACHMENT OF VERTICALLY INSTALLED
IWP PANELS
HORIZONTAL DHS PURLIN (OR SIMILAR)
AT EAVES LEVEL FOR MECHANICAL
ATTACHMENT OF PANEL
INTERMEDIATE POST
(IF REQUIRED)
HORIZONTAL RAIL
VERTICALLY
INSTALLED
IWP PANELS
PRIMARY STEEL
STRUCTURE
STEELWORK AT WIDTH
REQUIRED TO SUIT
PANEL INSTALLATION
HORIZONTAL DHS PURLIN (OR SIMILAR)
AT BASE OF WALL FOR ATTACHMENT
OF PANEL
System
INSULATED WALL PANEL (VERTICAL)
Detail
WALL FRAMING SET-OUT
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Drawing No.
RL IWP.V-11
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com
EXTENDED 30X5mm FLAT GALV GUTTER
BRACKET FIXED AT 750crs LAID TO FALL
WITH 2 SCREW FIXINGS IN PAN
50mm OVERHANG TO RL TOP DECK
DOWNTURN TO FORN EDGE
METAL ROOFING SCREW WITH
WASHER TO DESIGN SPECIFICATION
FOAM CLOSURE STRIP
RL TRAPEZOIDAL LONG RUN ROOFING
VAPOUR BARRIER
RL PIR RIGID INSULATION THICKNESS
DEPENDENT ON REQUIRED THERMAL
PERFORMANCE
RL VAPOUR RETRADER
RL BASE DECK
STEEL PURLIN
TOP EDGE OF RAFTER/PORTAL
TO DESIGN SPECIFICATION
System
INSULATED WALL PANEL (VERTICAL)
Detail
VERTICAL WALL/ROOF/GUTTER JUNCTION
This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.
Drawing No.
RL IWP.V-12
Scale
1:5
Date
May15
Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com