insulated wall panel

advertisement

EXTERNAL METAL LINER

INTERNAL METAL LINER

FACTORY APPLIED

WEATHER SEAL FACTORY APPLIED

WEATHER SEAL

System

INSULATED WALL PANEL (VERTICAL)

Detail

IWP MICROLINE DIMENSIONS

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Drawing No.

RL IWP.V-01

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com

EXTERNAL METAL LINER

INTERNAL METAL LINER

FACTORY APPLIED

WEATHER SEAL

FACTORY APPLIED

WEATHER SEAL

System

INSULATED WALL PANEL (VERTICAL)

Detail

IWP STANDARD

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Drawing No.

RL IWP.V-02

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com

EXTERNAL METAL LINER

INTERNAL METAL LINER

FACTORY APPLIED

WEATHER SEAL

FACTORY APPLIED

WEATHER SEAL

System

INSULATED WALL PANEL (VERTICAL)

Detail

IWP FLAT

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Drawing No.

RL IWP.V-03

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com

FACTORY APPLIED

WEATHER SEAL

EXTERNAL METAL LINER

INTERNAL METAL LINER

FACTORY APPLIED

WEATHER SEAL

System

INSULATED WALL PANEL (VERTICAL)

Detail

IWP PLANK

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Drawing No.

RL IWP.V-04

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com

VERTICAL PANEL JOINT & FASTENER LOCATIONS

DIRECTION OF

PREVAILING WIND

DIRECTION OF

INSTALLATION

CONCEALED MECHANICAL

FASTENER

PROJECT SPECIFIC CALCULATIONS AS

TO DESIGN WIND SPEEDS

System

INSULATED WALL PANEL (VERTICAL)

Detail

IWP PANEL JOINT AND FASTENER

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Drawing No.

RL IWP.V-05

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com

RL IWP 1150

VERTICALLY INSTALLED

CLOSER FLASHING

WITH CONTINUOUS

BUTYL BACK SEAL

0.55 COLOUR

COATED FLASHING

(ENSURE MATERIAL

COMPATIBILITY WITH

PANEL AND

SUBSTRATE)

CONTINUOUS RUN OF BUTYL

SEALANT

INTERNAL CLOSER FLASHING

CONTINUOUS RUN OF BUTYL

SEALANT

COMPRESSIBLE FOAM SEALING

BLOCK

RL 101 SEALANT ACROSS

JOIN

CLOSER FLASHING

WITH CONTINUOUS

BUTYL BACK SEAL

0.55 COLOUR COATED

FLASHING

RL IWP 1150

VERTICALLY INSTALLED

CONTINUOUS

BUTYL BACK SEAL

GALVANISED STEEL

BASE SUPPORT (CONTINUOUS)

BED BASE SUPPORT ON

2 RUNS OF RL101 SEALANT

COMPRESSIBLE FOAM SEALING

BLOCK

RL 101 SEALANT ACROSS

JOIN

System

INSULATED WALL PANEL (VERTICAL)

Detail

IWP BASE DETAIL

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Drawing No.

RL IWP.V-06

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com

CLOSER FLASHING, BACK

SEALED AND MECHANICALLY

ATTACHED ( ONE SIDE ONLY)

RL IWP 1150 WALL PANEL

VERTICALLY INSTALLED

0.55 COLOUR COATED AZ FLASHING INSTALLED WITH

SUFFICIENT FLASHING OVERLAP. FLASHING TO BE

BACK SEALED AT PANEL JUNCTION AND OVERLAPS

AND MECHANICALLY ATTACHED

INSTALLATION DIRECTION

System

INSULATED WALL PANEL (VERTICAL)

Detail

IWP EXTERNAL CORNER

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Drawing No.

RL IWP.V-07

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com

0.55mm COLOUR COATED AZ FLASHING INSTALLED

WITH SUFFICIENT FLASHING OVERLAP. FLASHING TO

BE BACK SEALED AT PANEL JUNCTION AND OVERLAPS

AND MECHANICALLY ATTACHED

CLOSER FLASHING, BACK

SEALED AND MECHANICALLY

ATTACHED ( ONE SIDE ONLY)

RL IWP 1150 WALL PANEL

INSTALLED VERTICALLY

INSTALLATION DIRECTION

System

INSULATED WALL PANEL (VERTICAL)

Detail

IWP INTERNAL CORNER

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Drawing No.

RL IWP.V-08

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com

PEF ROD WITH RL101 SEALANT

20MM WIDE

PIR BLOCK

0.55mm COLOUR COATED AZ FLASHING INSTALLED

WITH SUFFICIENT FLASHING OVERLAP, MECHANICALLY

ATTACHED AND SEALED.

RL IWP INSTALLED VERTICALLY

BACK SEAL WITH RL101 SEALANT

CLOSER FLASHING TO PANEL END

CONTINUOUS STEEL

BRACKET SUPPORT

0.55mm COLOUR COATED AZ FLASHING

INSTALLED WITH SUFFICIENT FLASHING OVERLAP,

MECHANICALLY ATTACHED AND SEALED.

RL IWP INSTALLED VERTICALLY

PEF ROD WITH RL101 SEALANT

20MM WIDE

PIR BLOCK

BACK SEAL WITH RL101 SEALANT

CLOSER FLASHING TO PANEL END

CONTINUOUS STEEL

BRACKET SUPPORT

System

INSULATED WALL PANEL (VERTICAL)

Detail

IWP JUNCTION WITH CONCRETE WALL (RECESSED)

Drawing No.

RL IWP.V-09

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com

CLOSURE FLASHING TO PANEL END

0.55mm COLOUR COATED AZ FLASHING INSTALLED

WITH SUFFICIENT FLASHING OVERLAP, MECHANICALLY

ATTACHED AND SEALED.

RL IWP INSTALLED VERTICALLY

BACK SEAL WITH RL101 SEALANT

CLOSURE FLASHING TO PANEL END

System

INSULATED WALL PANEL (VERTICAL)

Detail

IWP JUNCTION WITH CONCRETE WALL (EXPRESSED)

Drawing No.

RL IWP.V-10

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com

TYPICAL LAYOUT FOR STRUCTURAL

ATTACHMENT OF VERTICALLY INSTALLED

IWP PANELS

HORIZONTAL DHS PURLIN (OR SIMILAR)

AT EAVES LEVEL FOR MECHANICAL

ATTACHMENT OF PANEL

INTERMEDIATE POST

(IF REQUIRED)

HORIZONTAL RAIL

VERTICALLY

INSTALLED

IWP PANELS

PRIMARY STEEL

STRUCTURE

STEELWORK AT WIDTH

REQUIRED TO SUIT

PANEL INSTALLATION

HORIZONTAL DHS PURLIN (OR SIMILAR)

AT BASE OF WALL FOR ATTACHMENT

OF PANEL

System

INSULATED WALL PANEL (VERTICAL)

Detail

WALL FRAMING SET-OUT

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Drawing No.

RL IWP.V-11

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com

EXTENDED 30X5mm FLAT GALV GUTTER

BRACKET FIXED AT 750crs LAID TO FALL

WITH 2 SCREW FIXINGS IN PAN

50mm OVERHANG TO RL TOP DECK

DOWNTURN TO FORN EDGE

METAL ROOFING SCREW WITH

WASHER TO DESIGN SPECIFICATION

FOAM CLOSURE STRIP

RL TRAPEZOIDAL LONG RUN ROOFING

VAPOUR BARRIER

RL PIR RIGID INSULATION THICKNESS

DEPENDENT ON REQUIRED THERMAL

PERFORMANCE

RL VAPOUR RETRADER

RL BASE DECK

STEEL PURLIN

TOP EDGE OF RAFTER/PORTAL

TO DESIGN SPECIFICATION

System

INSULATED WALL PANEL (VERTICAL)

Detail

VERTICAL WALL/ROOF/GUTTER JUNCTION

This drawing is the copyright of Eagle Insulations. Modification of details for job specification requirements must be approved by Eagle Insulations. The building designer is ultimately responsible to ensure all building work is designed and constructed according to Building Code requirements, UK Standards and best code of practice industry guidelines. All components must be supplied by Eagle Insulations. Eagle Insulations reserves the right to alter or upgrade details at any time without prior notice.

Drawing No.

RL IWP.V-12

Scale

1:5

Date

May15

Eagle Insulations Ltd. 39 Alma Road, St. Albans, Herts AL1 3AT info@eagle-insulations.com www.eagle-insulations.com