combination reversing starter/wall-mounted starter

COMBINATION REVERSING
STARTER/WALL-MOUNTED
STARTER
WARNING
WARNING
WALL MOUNTED STARTER APPLICATION:
CAUTION
The wall-mounted starter modification provides all control
equipment that is not mechanically connected to the
operator powerhead in a separate wall mounted enclosure.
The limit switches and brake solenoid (when present)
remain on the operator. The starter, control transformer,
control relays, and other optional components are pre-wired
in the wall mounted enclosure. Terminal points are provided
for both the inter-wiring between operator/starter and for
the connection of control stations and safety equipment.
COMBINATION REVERSING STARTER
APPLICATION:
The combination reversing starter with disconnect switch or
circuit breaker modification provides all control equipment
that is not mechanically connected to the operator
powerhead in a separate wall mounted enclosure. The limit
switches and brake solenoid (when present) remain on the
operator. A fusible, nonfusible, or circuit breaker with
external handle is supplied which shuts off main power to
the unit (and operator) when the cover is opened. The
starter itself is an industrial size 0 but may be upgraded to
size 1 and the control transformer rated 50VA but may be
upgraded to 100VA. Terminal points are provided for both
the inter-wiring between operator/starter and for the
connection of control stations and safety equipment.
Includes an automatically resettable overload relay which
may be converted to manual reset, but cover of starter must
be open to reset.
See to the right for enclosure, disconnect type, and voltage
variations.
01-12782C
ADDENDUM
WARNING
It is strongly recommended that safety equipment be
used in conjunction with this operator.
WALL-MOUNTED STARTERS
PART NUMBER
90-3001
90-3002
90-3004
90-3012
ENCLOSURE TYPE
NEMA 1 Screw Cover Enclosure
NEMA 1 Hinged Cover Enclosure
NEMA 4 Hinged Cover Enclosure
NEMA 12 Hinged Cover Enclosure
COMBINATION REVERSING STARTERS
PART NUMBER
90-6002
90-6004
90-6012
90-70001
90-7004
90-7012
90-80012
90-80014
90-80016
90-80042
90-80044
90-80046
90-80122
90-80124
90-80126
© 2007, The Chamberlain Group, Inc.
All Rights Reserved
ENCLOSURE TYPE
NEMA 1 with NFDS
NEMA 4 with NFDS
NEMA 12 with NFDS
NEMA 1 with FDS
NEMA 4 with FDS
NEMA 12 with FDS
NEMA 1, 250V with CB
NEMA 1, 480V with CB
NEMA 1, 600V with CB
NEMA 4, 250V with CB
NEMA 4, 480V with CB
NEMA 4, 600V with CB
NEMA 12, 250V with CB
NEMA 12, 480V with CB
NEMA 12, 600V with CB