BURNER MANAGEMENT SYSTEM
PRODUCT OVERVIEW
The PF2100 BMS (Burner Management System) is an advanced electronic
control and monitoring system designed for use on a wide variety of natural
draft burner industrial applications up to 12.5MM BTU/h including:
•
•
•
•
•
•
•
•
Amine Reboilers
Combustors
Dehydrators
Gas Production Units
Heated Seperators
Incinerators
Line Heaters
Treaters
SAFETY AND PROTECTION
•
•
•
Designed to protect personnel and equipment
Integrated critical safety shutdown inputs
Risk management of workplace hazards
KEY FEATURES
CONVENIENCE
FLEXIBILITY
RELIABILITY
Integrated
• High temperature shutdown
• Temperature control
• History and event log
• 4-20 output
Auto ignition and re-light with proven spark
■
■
USER FRIENDLY DISPLAY AND INTERFACE
Temperature out
Valve control
Advanced flame detection circuit
Approved temperature range
• -40°C to 55°C
• -40°F to 131°F
Low power requirement
Strict manufacturing and Quality Assurance
Stackable Expansion cards available
• Modbus RS485
• 4-20 input for pressure and tank level
processes provide consistency and dependability
Dual processors for failsafe operation
APPROVALS
Class 1, Division 2, Grp ABCD; T4A
CSA Type 4X
CSA 22.2 No. 199-2007
ANSI Z21.20-2007
UL1998-2004
1 855 PRO FIRE
www.profireenergy.com
CSA C22.2 No. 0-M91
CSA C22.2 No. 0.4-04
CSA C22.2 No. 94-91
CSA C22.2 No. 142-M1987
CSA C22.2 No. 213-M1987
CSA E60730-1:02
PROFIRE ENERGY INC.
Bay 12, 55 Alberta Ave
Spruce Grove, AB T7X 3A6
Canada
CSA E60079-0:2007
CSA E60079-15:2005
UL 508, 17th Edition
ANSI-ISA-12.12.01-2007
UL 60079-0:2005
UL 60079-15:2002
PROFIRE ENERGY INC.
321 South 1250 West
Lindon, UT 84042
USA
PROFIRE ENERGY INC.
19407 Park Row, Suite 100
Houston, TX 77084
USA
VM80
C O N T R O L V A LV E A C T U AT O R
PRODUCT OVERVIEW
The Profire VM80 is an industrial grade actuator designed for fuel gas systems,
providing precision, consistency and repeatability.
The VM80 Actuator uses a 4-20mA control signal to accurately position the
valve. Designed to provide precision and repeatable flow control performance,
the VM80 is ideal for applications wherein modulation and tighter temperature
control is desired, such as:
•
•
•
•
•
•
Glycol Treaters & FWKOs
Glycol and Amine Reboilers
Line and Utility Heaters
Combusters and Incinerators
GPU’s
Salt Baths and Hot Oilers
KEY FEATURES
•
•
•
•
•
Simple installation, no local programming required
Class 1, Division 1 - Hazardous location approvals
Replaces the need for I2P, Instrument Air and related devices
Easy to see visual position indicator
Non venting
SPECIFICATIONS
PF VM80
MATERIAL SPECIFICATIONS
5.25
5.25
6.62
13.94
4.06
3.26
OPERATION SPECIFICATIONS
Enclosure material:
Yoke:
Cover:
Aluminum
6061-T6
A356-T6
Operating Temp:
-40 to 55 °C
(-40 to 131°F)
Supply Voltage:
12 or 24 V DC
Springs / Retaining Rings:
Alloy X750
Current Draw:
2.3 A Max, 90 mA Idle
Elastomers:
FKM
Control Signal:
4-20 mA
Conduit Connections:
One 1/2” NPT
Travel (Nominal):
12.7 mm (0.5 inch)
Class 1, Division 1
4.45
.40
3.25
Operating Thrust: 355 N (80 lbf) at 12 V DC
387 N (87 lbf) at 24 V DC
2.00
APPROVALS
CSA Hazardous Locations Approvals
General: CSA 60079-0 ISA 60079-0 FM 3600
Explosion Proof: CSA C22.2 No. 30 UL 1203
Flame Proof: CSA 60079-1 ISA 60079-1
Markings: Class 1, Division 1, T6 Class 1, Zone 1
AEx dIIC T6, Groups B, C, and D
1 855 PRO FIRE
www.profireenergy.com
PROFIRE ENERGY INC.
Bay 12, 55 Alberta Ave
Spruce Grove, AB T7X 3A6
Canada
Enclosure Ratings and Standards
IP66: C22.2 No. 60529 IEC 60529
Type 4, 4X: CSA C22.2 No. 94.1 UL 50
MMX-J-235/1-ANCE CSA C22.2 No. 94.2
UL 50E MMX-J-235/2-ANCE NEMA 250
PROFIRE ENERGY INC.
321 South 1250 West
Lindon, UT 84042
USA
PROFIRE ENERGY INC.
19407 Park Row, Suite 100
Houston, TX 77084
USA
1800
BURNER MANAGEMENT SYSTEM
PRODUCT OVERVIEW
The PF1800 provides basic Burner Management System functionality, with
integrated critical system shutdown inputs. It has been specifically designed
for natural draft heaters operating at less than 3.5 MM BTU/h, with industry
applications in:
•
•
•
•
•
•
•
Combustors
Dehydrators
Gas Production Units
Heated Seperators Incinerators
Line Heaters
Treaters
SAFETY AND PROTECTION
•
•
•
Designed to protect personnel and equipment
Integrated critical safety shutdown inputs
Risk management of workplace hazards
KEY FEATURES
CONVENIENCE
ST
RU
NN
IN
OP
G
PE
D
OK
OFF
RELIABILITY
Integrated
• High temperature shutdown
• On / Off temperature control
• Level and pressure inputs
• Remote Start / Stop
Advanced flame detection circuit
SERIAL NO.
MC#248705
1101-029-S0000 Rev 1.0
USER FRIENDLY DISPLAY AND INTERFACE
Auto ignition and re-light with proven spark
Live process setpoint adjustment
Approved temperature range
• -40°C to 55°C
• -40°F to 131°F
Internal or external coil (optional)
Strict manufacturing and Quality Assurance
Easy setup and operation
processes provide consistency and dependability
Low power design
Dual processors for failsafe operation
ON
BURNER
MANAGEMENT SYSTEM
8
1PS18-S0000
1 855 PRO FIRE
12VDC, 2.6W Display ON
12VDC, 1.1W Display OFF
24VDC, 2.9W Display ON
24VDC, 1.2W Display OFF
12VDC, 5A max INDUCTIVE
24VDC, 5A max INDUCTIVE
AMBIENT: -40˚C - +55˚C
OUTPUT:
INPUT:
WARNING: EXPLOSION HAZARD
DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS
AREA IS KNOWN
TO BE NON-HAZARDOUS OR EQUIVALENT
AVERTISSEMENT: RISQUE D’EXPLOSION
NE PAS DEBRANCHER TANT QUE LE CIRCUIT EST SOUS
TENSION, A
MOUNS QU’IL NE S’AGISSE D’UN EMPLACEMENT
NON DANGEREAUX
WARNING: EXPLOSION HAZARD
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY
FOR
CLASS I, DIVISION 2.
AVERTISSEMENT: RISQUE D’EXPLOSION
LA SUBSTITUTION DE COMPOSANTS PEUT RENDURE
CE MATERIEL
INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE
I, DIVISION 2
THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I,
DIVISION 2,
GROUPS ABCD OR NON-HAZARDOUS LOCATIONS
ONLY.
UL1998-2004
CSA 22.2 No. 199-2007
ANSI Z21.20-2007
Class I, Div 2, Grp ABCD; T4A
CSA Type 4
1800
MODEL NO.
FLEXIBILITY
APPROVALS
Class 1, Division 2, Grp ABCD; T4A
CSA Type 4
CSA 22.2 No. 199-2007
ANSI Z21.20-2007
UL1998-2004
1 855 PRO FIRE
www.profireenergy.com
CSA C22.2 No. 0-M91
CSA C22.2 No. 0.4-04
CSA C22.2 No. 94-91
CSA C22.2 No. 142-M1987
CSA C22.2 No. 213-M1987
CSA E60730-1:02
PROFIRE ENERGY INC.
Bay 12, 55 Alberta Ave
Spruce Grove, AB T7X 3A6
Canada
CSA E60079-0:2007
CSA E60079-15:2005
UL 508, 17th Edition
ANSI-ISA-12.12.01-2007
UL 60079-0:2005
UL 60079-15:2002
PROFIRE ENERGY INC.
321 South 1250 West
Lindon, UT 84042
USA
PROFIRE ENERGY INC.
19407 Park Row, Suite 100
Houston, TX 77084
USA
Download