Application
Products with approvals for
several markets (“MultiStandard”) make it possible to
cover different national
requirements with only one
product. The multi standard
wiring cable UL(MTW)-CSA-HAR
fulfills the European Harmonisation Standards (HAR) as well
as the US and Canadian
Standards (UL, CSA) and can
therefore be used in the most
important global markets.
Thereby the economic
efficiency in production can be
increased and the technical
documentation as well as the
storage will be significantly
simplified. By using the multi
standard wiring cable the
international operating or
export-oriented producer of
machines, equipments and
installations can work more
efficient and avoid acceptance
problems with local inspectors/
authorities or customers
abroad.
Special Feature
In addition to the AWG
(appliance wiring material)recognition this product is also
UL(MTW)listed. Its MTW-listing
(Machine Tool Wire) allows the
use of this cable in the
complete machine tool industry
(not only in appliances).
Another benefit of a UL-Listed
product is its highest acceptance because uses of
UL-Listing products are
published by National Electric
Code and NFPA 79 in USA.
These standards are available
for any safety inspector.
UL (MTW)-listed,
oil resistant,
+105°C
AWM 600V
Note
The multi standard wiring cable
is conform to EEC directive 73/
23 (Low Voltage Directive) CE.
Please note: mm² and AWG/
MCM conductor sizes of
multinorm cables do have
special conductor strands, so
one of both of the conductor
sizes is typically oversized
regarding to its nominal cross
section.
Cable Make-up
Stranded conductor of tinned
copper wires acc. with UL-CSA,
fine wire in acc. with VDE 0295
Cl.5/IEC 60228 Cl.5, insulation
of special PVC compound to
IEC 60227/VDE 0207, UL 1581
class 12 and 43; oil-resistant,
flame-retardant and selfextinguishing in acc. to IEC
60332.1/HD 405.2 and CSA
FT1.
UL(MTW)-CSA-HAR Style 1015
as special version “bare copper
strands” on request.
UL-CSA-HAR Style 1007+1569 not MTW listed
Technical Data
T
g
Temperatur range:
fixed:
HAR/IEC: -40°C up to
+70°C
UL-CSA: -40°C up to +105°C
Conductor stranding:
fine wire stand acc. with
VDE 0295,
Class 5 / IEC 60228 Cl.5
Part number
41804 . .
41805 . .
41806 . .
4.6
b
Nominal voltage U0/U:
H05V-K: 300/500 V
UL+CSA: U: 300V
W
B
Insulation: specific insulation
resistance: > 10 GOhm x cm
Cross section
mm2
D
Approval:
UL: AWM Style 1007, 1569
CSA: TEW
HAR: H05V-K
(VDE 0281/HD 21)
Test voltage: 2500 V
Cross section
in AWG
UL AWM Style 1007 + 1569, CSA TEW, H05V-K
0,5
22
0,75
20
1,0
18
Approx. outer diameter
in mm
2,2
2,4
2,5
Copper weight
kg/km
4,8
7,2
9,6
Approx. weight kg/km
8,6
11,2
13,6