New Multi-Standard wiring cable UL(MTW)-CSA-HAR The “international” approved single core Style 1015 Application Products with approvals for several markets (“MultiStandard”) make it possible to cover different national requirements with only one product. The multi standard wiring cable UL(MTW)-CSA-HAR fulfills the European Harmonisation Standards (HAR) as well as the US and Canadian Standards (UL, CSA) and can therefore be used in the most important global markets. Thereby the economic efficiency in production can be increased and the technical documentation as well as the storage will be significantly simplified. By using the multi standard wiring cable the international operating or export-oriented producer of machines, equipments and installations can work more efficient and avoid acceptance problems with local inspectors/ authorities or customers abroad. Special Feature In addition to the AWG (appliance wiring material)recognition this product is also UL(MTW)listed. Its MTW-listing (Machine Tool Wire) allows the use of this cable in the complete machine tool industry (not only in appliances). Another benefit of a UL-Listed product is its highest acceptance because uses of UL-Listing products are published by National Electric Code and NFPA 79 in USA. These standards are available for any safety inspector. UL (MTW)-listed, oil resistant, +105°C AWM 600V Note The multi standard wiring cable is conform to EEC directive 73/ 23 (Low Voltage Directive) CE. Please note: mm² and AWG/ MCM conductor sizes of multinorm cables do have special conductor strands, so one of both of the conductor sizes is typically oversized regarding to its nominal cross section. Cable Make-up Stranded conductor of tinned copper wires acc. with UL-CSA, fine wire in acc. with VDE 0295 Cl.5/IEC 60228 Cl.5, insulation of special PVC compound to IEC 60227/VDE 0207, UL 1581 class 12 and 43; oil-resistant, flame-retardant and selfextinguishing in acc. to IEC 60332.1/HD 405.2 and CSA FT1. UL(MTW)-CSA-HAR Style 1015 as special version “bare copper strands” on request. UL-CSA-HAR Style 1007+1569 not MTW listed Technical Data T g Temperatur range: fixed: HAR/IEC: -40°C up to +70°C UL-CSA: -40°C up to +105°C Conductor stranding: fine wire stand acc. with VDE 0295, Class 5 / IEC 60228 Cl.5 Part number 41804 . . 41805 . . 41806 . . 4.6 b Nominal voltage U0/U: H05V-K: 300/500 V UL+CSA: U: 300V W B Insulation: specific insulation resistance: > 10 GOhm x cm Cross section mm2 D Approval: UL: AWM Style 1007, 1569 CSA: TEW HAR: H05V-K (VDE 0281/HD 21) Test voltage: 2500 V Cross section in AWG UL AWM Style 1007 + 1569, CSA TEW, H05V-K 0,5 22 0,75 20 1,0 18 Approx. outer diameter in mm 2,2 2,4 2,5 Copper weight kg/km 4,8 7,2 9,6 Approx. weight kg/km 8,6 11,2 13,6