AIRSYS-P-SC-GENERAL-E1408V01.5
AIRSYS
Expert in ICT Cooling
AIRSYS Refrigeration Engineering Technology (Beijing) Co.,Ltd
Brief Introduction
Airsys is a world major player in ICT cooling with a wide range of
product including Precision Air-conditioner for computer room and data
center, air-conditioner and Intelligent Free Cooling unit for BTS station,
air-conditioner and heat exchanger for various type of cabinets, chillers
for data center cooling source. All product is highly reliable and energy
efficient.
Airsys provide the full solution and service to its customer such as
product selection, design and development, manufacturing, installation,
after-sale service and contract operation.
1995
1999
2001
Founded in Beijing as the distributor
Introduced Airsys Brand chiller and
ISO9001 certified. Introduced
of a major European ICT cooling
become a HVAC manufacturer.
Airsys Brand Precision Air-
manufacturer, established the
conditioner.
national sales & distribution
network.
2007
2008
2009
Obtained the record making
New GuAnproduction facility
Became global s
shelter air-conditioner PO from
completed, 30,000 sqm of covered
supply various IC
Reliance Communication, an
plant and 80,000 sqm of total area,
Indian telecom operation.
became one of the leader in ICT
Became strategic partner of
cooling.
China Mobile to develop the high
“2008 Technology Innovation
energy efficient air-conditioner for
Award for Green Telecom China”
its green shelter project.
Became global supplier for
Siemens Healthcare.
2
2003
2004
2006
Elected as “Best Employer” by
New production facility in Beijing
Attended the ITU exhibition and
<Fortune> Chinese Edition.
completed.
started the strategic development of
Became global supplier for
the international market.
GE Healthcare and got the
“Technology Innovation Award” of
the year.
2010
2011
supplier of Vodafone,
The packaged outdoor shelter air-
Became the global supplier for
CT cooling products.
conditioner passed the quality audit
Phillips Healthcare and got well
and on site energy efficiency test of
acknowledged by the customer.
Verizon Wireless, became a part of
Became the global supplier of
their new shelter HVAC standard.
British Telecom, providing site
Became its first Chinese supplier and
survey, installation with the newly
start the bunch supply.
established Airsys UK.
3
Core Value
Reliability
Reliability means supplying reliable products and services and winning trusts
from happy customers in order to win the market.
Efficiency
Efficiency means optimizing resource distribution to ensure sustainable
business development and maximizing profit margins.
Responsibility
Responsibility means being responsible to shareholders, customers,
employees, suppliers, and the society in large.
Respect
Respect means respecting to shareholders, customers, employees,
suppliers and partners.
Social Responsibility
AIRSYS will always devote to fulfill the social responsibility of all aspects, providing
more environment friendly products, protecting the sustainable development of global
environment. Also,we contribute to the development of region and happiness, health
and sustainable development of employees and their families.
Vision
A major global supplier of product and service in ICT and related industries.
4
Manufacturing Facility
As the largest ICT cooling product manufacturing facility in Asia, Airsys GuAn has
a total area of 80,000 sqm among which 30,000 sqm are covered plant. Equipped
with production line for heat exchanger, sheet metal, powder painting, assembly line
and performance test chamber, this facility can produce different type of ICT cooling
product or more than 100,000 units a year.
Energy Saving
World is facing the challenge of energy shortage, especially in ICT industry,the revolution in
information storage, processing and transmission result more and more energy consumption.
Energy efficiency has always been the core value and responsibility of Airsys. We use various
kind of technologies, such as free cooling chiller, air-conditioner, independent free cooling unit, EC
fan, DC compressor, battery cooler, scroll compressor and displacement air distribution scheme,
to help our customer to cut their energy bill
High Reliability
ICT environment cooling requires high reliability. Airsys has always taken reliability
as the most important value and build into every aspect of our business process
and every employee’s mind. We assure every product produced is highly reliable by
selection of component, design validation, IE and QC, 100% test, process control on
installation and service. Our product meet various international standard such as CE,
UL, RoHS, CCC.
Research and Development
Our R&D team is formed by experienced HVAC AND electric engineers. Apart from the standard
products, we have rich experience in developing custom made products for our customer. We
can quickly deliver the technical proposal, prototype, laboratory performance test report and real
site test according to customer’s requirement.
Service Network
Airsys has a well established service network throughout China and major international
regions. Our team, call center and CRM platform provide fast and professional service
covering installation, emergency intervention, maintenance, contract operation, online
failure analysis, IAQ analysis.
5
Airsys and ICT Industry
Telecom Operator – China Mobile
Telecom Operator – Verizon Wireless
Major Cooling Supplier
Gone through 3 years of real site testing, highly recognized
Strategic Partner for “Green Action Plan”
by the customer for its reliability, energy efficiency and
Research and consulting service on shelter cooling energy
saving and related standard, developing the software for
energy saving calculation, product.
overall performance. Specified in the new Verizon Wireless
Shelter standard. Become its first Chinese supplier.
Supply CRAC for its large Data Center.
Telecom Equipment Supplier- ZTE
Telecom Operator – China Telecom
Major Cooling Supplier
Long Term Partner, supply CRAC for its large Data Center.
Telecom Operator – Vodafone
Global Cooling Supplier
Jointly develop various cooling product with significant
energy saving features.
Long Term Partner
Supply all range of product from Cabinet cooling to Data
Center cooling.
ICT Power Equipment Supplier-Delta, Eltek
Strategic Partner
Supply all range of cooling product from cabinet to data
center.
Help to improve both CAPEX and OPEX
Data Center Operator, Internet Companies
Telecom Operator – British Telecom
Global Cooling Supplier
Develop custom made cooling product.
Provide turnkey solution including site survey, installation,
and product supply.
Telecom Operator –Reliance Communication
Strategic Cooling Supplier
Completed Design, Prototype and Pilot order within 3
months, delivered 25,000 units within 12 months period.
The units have shown the best of its kind in terms of failure
rate, energy consumption in the market of India.
Won the Best Supplier Award in year 2007 and 2008.
6
Supply full solution for Data Center.
Sales and service network
Airsys Refrigeration Engineering Technology
(Beijing) Co.,Ltd
Gu'an Airsys Environmental Technology Co. Ltd
Shanghai Airserve HVAC Systerm Service Co., Ltd.
Technical Support and Logistic Center
EU-CIS-India
North America
Middle East & Africa
Airsys Group (HK) Co., Ltd.
Airsys (UK) Ltd.
Sales & Distribution
Asia Pacific: India, Pakistan, Nepal, Australia,
Singapore, Indonesia, Malaysia, Vietnam, Philipine
EMEA: Russia, France, UK, Romania, Spain, Czek,
Italy, Turkey, South Africa, Nigeria.
Americas: USA, Canada, Mexico, Ecuador.
7
Airsys product &solutions
Cabinet
TELECOOL
Cooling capacity:0.3~3kW
Telecom Shelter
MOBILECOOL-OUTDOOR
Cooling capacity:3.5~17.9 kW
Data Center
OPTIMA.DXA/DXW
Cooling capacity:17.6~106.7kW
OPTIMA-FC.DXA/DXW
Cooling capacity:17.6~106.7kW
OPTIMA-INV.DXA/DXW
Cooling capacity:16.3~115.4kW
OPTIMA-FC-INV.DXA/DXW
Cooling capacity:16.1~115.4kW
OPTIMA.CW/CWD
Cooling capacity:24.8~134.5kW
Air-
MOBILECOOL-INDOOR
Cooling capacity:3.4~13.3 kW
conditioner
OPTIMA-HD.CW/CWD
Cooling capacity:42.1~180.9 kW
DATACOOL
Cooling capacity:5.8~30.2 kW
DATACOOL-PACKAGE
Cooling capacity:9.1~48.6 kW
Outdoor condenser and dry cooler
Cooling capacity:9.3~83.1 kW
MOBILECOOL-SPLIT
Cooling capacity:5.5~14.9kW
METROCOOL
Cooling capacity:5.2~13.0kW
Chiller
CRITICOOL
Cooling capacity:115~1508 kW
HYDROCOOL
Cooling capacity:229.5~3641.2 kW
CRITICOOL-FC
Cooling capacity:114~1493 kW
Ventilation
& Heat
Exchanger
FREECOOL
Air flow: 1000~3450 m3/h
8
FREECOOL-HD
Air flow: 2400~21600 m3/h
OPTIMA/OPTIMA-INV
OPTIMA family includes standard series of OPTIMA and DC inverter series
of OPTIMA-INV, is applicable to large and medium-sized data center and
electronic equipment room. It has a wide range cooling capacity, high
operating reliability and stability. Equipped with EC fan, precise control of
temperature ±1℃, relative humidity ±5% which can assure the reliable and
stable environment of the data room.
Standard series of OPTIMA has various type of cooling system, direct
expansion with air-cooled condenser, direct expansion with water-cooled
condenser, chilled water with either single coil or double coil. DC inverter
series of OPTIMA-INV has two types of cooling schemes: direct expansion
with air-cooled condensers, direct expansion with water-cooled condenser.
There are up flow and down flow for supply air and up, down, front and back
for return air to meet the different needs of equipment room. All units can be
easily maintained from the front.
Direct expansion air-cooled (DXA) work with CME or AMAE air-cooled
condenser.
Direct expansion water-cooled (DXW) work with CMEH dry cooler or central
cooling tower and pumping group.
OPTIMA.DXA/DXW
Model
Supply air scheme
Power source
Cooling capacity
DXA(1)
DXW(2)
Compressor
Supply fan
Type
Qty. of fan
Air volume
Electric heater capacity
Humidification capacity
Air cooled
condenser(DXA)
Width*Depth*Height
DXA Weight
DXW Weight
16E1A1 20E1A1 26E1A2 30E1A2 35E1A2 40E2A3 50E2A3 60E2A4 70E2A4 80E2A4 90E2A5 100E2A5
O:Up flow; U:Down flow
380V-3Ph-50Hz
kW
kW
18.9
17.6
22.0
21.5
28.5
27.9
31.9
31.2
37.6
36.1
n.
m3/h
kW
Kg/h
1
5750
6
3
1
6320
6
3
1
8900
9
5
1
9600
9
5
1
9600
9
5
CME5*1
mm
Kg
Kg
46.6
55.1
65.3
45.8
57.2
62.1
Hermetic Scroll Type
EC Centrifugal Fan
2
2
3
12600 13600 17800
13.5
13.5
18
8
8
8
74.5
72.2
84.6
82.3
90.7
90.4
103.4
106.7
3
19200
18
8
3
21000
18
8
3
24600
18
8
3
27900
18
8
CME8*1 CME10*1 CME10* CME15*1 CME8*2 CME10*2 CME10*2 CME15*2 CME15*2 CME20*2 CME20*2
875*890*1960
310
360
322
374
1480*890*1960
370
410
415
385
423
431
1750*890*1960
620
670
656
709
2490*890*1960
930
980
1020
971
1013
1076
3095*890*2050
1210
1250
1256
1300
(1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃;
(2) Return air dry bulb temperature 24℃,RH50%,inlet condensing water temperature 30℃, standard water flow.
9
OPTIMA-INV.DXA/DXW
Model
Supply air scheme
Power source
Cooling capacity
DXA(1)
DXW(2)
Compressor
Supply fan
Type
Qty. of fan
Air volume
Electric heater capacity
Humidification capacity
Air cooled
condenser(DXA)
Dry cooler(DXW)
Width*Depth*Height
DXA Weight
DXW Weight
16E1A1 22E1A2 30E1A2 35E2A3 45E2A3 55E2A3 60E2A4 70E2A4 80E2A4 90E2A5 110E2A5
O:Up flow; U:Down flow
380V-3Ph-50Hz
kW
kW
16.3
17.2
22.3
23.5
30.2
32.1
36.9
36.8
47.2
55.2
61.6
70.8
48.1
56.4
63.5
73.5
Hermetic DC Inverter Scroll Type
n.
Kg/h
1
5750
6
3
1
8900
9
5
1
9600
9
5
2
12600
13.5
8
EC Centrifugal Fan
2
2
3
12600 13600 17800
13.5
13.5
18
8
8
8
112.8
115.4
3
21000
18
8
3
24600
18
8
3
27900
18
8
AMAE6*1
AMAE8*2 AMAE10*2 AMAE12*2 AMAE15*2 AMAE18*2
AMAE20*2
Model*n.
CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2
CMEH70*2
875*890*1960
348
395
1480*890*1960
440
490
475
510
AMAE8*2
92.3
93.7
Model*n.
mm
Kg
Kg
AMAE8*1 AMAE10*1 AMAE6*2
3
19200
18
8
80.3
82.3
1750*890*1960
710
750
750
810
2490*890*1960
790
860
960
1080
1010
1130
3095*890*2050
1150
1250
1270
1430
1350
1540
(1) Return air dry bulb temperature 24℃,RH50%,outdoor dry bulb temperature35℃, variable speed compressor is operating at
economicspeed;
(2) Return air dry bulb temperature 24℃,RH50%, inlet condensing water temperature 30℃, water flow under standard condition, variable
speed compressor is operating at economic speed .
OPTIMA.CW/CWD
Model
Supply air scheme
Power source
Cooling capacity(1)
Supply fan
Type
Qty. of fan
Air volume
Electric heater capacity
Humidification capacity
Width*Depth*Height
CW Weight
CWD Weight
kW
n.
m3/h
kW
Kg/h
mm
Kg
Kg
20A1
30A1
40A2
24.8
30.3
40.8
1
1
6750
6750
6
6
3
3
875*890*1960
310
335
327
356
45A2
55A3
65A3
80A4
O:Up flow; U:Down flow
380V-3Ph-50Hz
47.7
55.8
66.5
80.5
1
1
9600
9600
9
9
5
5
1480*890*1960
380
410
408
448
EC Centrifugal Fan
2
2
15300
15300
13.5
13.5
8
8
1750*890*1960
470
510
504
556
(1) Return air dry bulb temperature 24℃,RH50%,inlet/outlet chilled water temperature 7℃/12℃.
10
100A4
120A5
140A5
100.2
112.1
134.5
3
3
21600
21600
18
18
8
8
2490*890*1960
550
575
600
642
3
3
28900
28900
18
18
8
8
3095*890*2050
660
690
730
785
OPTIMA-FC/OPTIMA-FC-INV
OPTIMA-FC precision air conditioner integrated with free cooling for critical
application,including standard series of OPTIMA-FC and DC inverter series
of OPTIMA-FC-INV, is applicable to large and medium-sized data center
and electronic equipment room. It has a wide range cooling capacity, high
operating reliability and stability. Equipped with EC fan, precise control of
temperature±1℃, relative humidity ±5% which can assure the reliable and
stable environment of the data room.For double cooling source version, the
unit can provide cooling by either chilled water or direct expansion cooling,
providing higher reliability and flexibility for efficient operation. Free Cooling
version can greatly reduce the energy consumption and cut the energy bill.
OPTIMA-FC/OPTIMA-FC-INV has two direct expansion cooling type, aircooled and water-cooled. There are two schemes of supply air--up supply
and down supply can be provide to different needs of equipment room. Easily
maintain from the front of the product.
OPTIMA-FC/OPTIMA-FC-INV has three working mode:mechanical cooling,
partial free cooling and free cooling only.
OPTIMA-FC/OPTIMA-FC-INV series double cooling source version has three
working mode, mechanical cooling, chilled water cooling and double cooling
source.
Direct expansion air-cooled (DXA) work with CME or AMAE condenser.
Direct expansion water-cooled (DXW) work with CMEH dry cooler or central
cooling tower and pumping group.
Chilled water coil work with chiller plant, central cooling tower or CMEH dry
cooler and pumping group.
OPTIMA-FC.DXA/DXW
Model
Supply air scheme
Power source
Cooling capacity
DXA(1)
DXW(2)
Free cooling capacity(3)
DXA
DXW
Compressor
Supply fan
Type
Qty. of fan
Air volume
Electric heater capacity
Humidification capacity
Air cooled condenser(DXA)
Dry cooler(DXA)
Dry cooler(DXW)
Width*Depth*Height
DXA Weight
DXW Weight
16E1A1 20E1A1 26E1A2 30E1A2 35E1A2 40E2A3 50E2A3 60E2A4 70E2A4 80E2A4 90E2A5 100E2A5
O:Up flow; U:Down flow
380V-3Ph-50Hz
kW
kW
18.9
17.6
22
21.5
28.5
27.9
31.9
31.2
37.6
36.1
46.6
45.8
kW
kW
16.5
16.5
21.8
21.8
30.1
30.1
33.6
33.6
37.6
37.6
n.
m3/h
kW
Kg/h
1
5750
6
3
1
6320
6
3
1
8900
9
5
1
9600
9
5
1
9600
9
5
Model*n.
CME5*1
CME8*1
CME10*1
CME10*
CME15*1
55.1
57.2
65.3
62.1
74.5
72.2
84.6
82.3
90.7
90.4
103.4
106.7
42.4
50.3
55.9
42.4
50.3
55.9
Hermetic Scroll Type
67.3
67.3
78.5
78.5
93.4
93.4
104.6
104.6
3
19200
18
8
3
21000
18
8
3
24600
18
8
3
27900
18
8
CME10*2 CME10*2 CME15*2 CME15*2 CME20*2
CME20*2
EC Centrifugal Fan
2
2
3
12600 13600 17800
13.5
13.5
18
8
8
8
CME8*2
Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH40*1 CMEH50*1 CMEH50*1 CMEH60*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH60*2
Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2
mm
Kg
Kg
875*890*1960
315
366
348
405
1480*890*1960
375
413
420
423
464
476
1750*890*1960
630
680
708
770
2490*890*1960
940
980
1040
1037
1085
1157
3095*890*2050
1230
1270
1338
1392
(1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃;
(2) Return air dry bulb temperature 24℃,RH50%,inlet chilling water temperature 30℃, standard chilling water flow under standard condition;
(3) Return air dry bulb temperature 24℃,RH50%,Outdoor temperature 2℃, standard chilling water flow under standard condition.
11
OPTIMA-FC-INV.DXA/DXW
Model
Supply air scheme
Power source
Cooling capacity
DXA(1)
DXW(2)
Free cooling capacity(3)
DXA(3)
DXW(3)
Compressor
Supply fan
Type
Qty. of fan
Air volume
Electric heater capacity
Humidification capacity
Air cooled condenser(DXA)
Dry cooler(DXA)
Dry cooler(DXW)
Width*Depth*Height
DXA Weight
DXW Weight
16E1A1
22E1A2
30E1A2
35E2A3
45E2A3
55E2A3
60E2A4
70E2A4
80E2A4
90E2A5 110E2A5
O:Up flow; U:Down flow
380V-3Ph-50Hz
kW
kW
16.1
17.2
22.2
23.5
30.1
32.1
35.5
36.8
70.3
73.5
80.1
82.3
91.5
93.7
111.9
115.4
kW
kW
17.1
17.1
23.5
23.5
34.5
34.5
37.8
41.7
57.1
63.6
75.3
37.8
41.7
57.1
63.6
75.3
Hermetic DC Inverter Scroll Type
84.4
84.4
93.4
93.4
114.6
114.6
n.
m3/h
kW
Kg/h
Model*n.
Model*n.
Model*n.
mm
Kg
Kg
1
5750
6
3
1
8900
9
5
1
9600
9
5
3
21000
18
8
3
24600
18
8
3
27900
18
8
AMAE6*1
2
12600
13.5
8
AMAE8*1 AMAE10*1 AMAE6*2
46.7
48.1
55.2
56.4
61.2
63.5
EC Centrifugal Fan
2
2
3
12600 13600 17800
13.5
13.5
18
8
8
8
AMAE8*2
3
19200
18
8
AMAE8*2 AMAE10*2 AMAE12*2 AMAE15*2 AMAE18*2 AMAE20*2
CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2
CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2
875*890*1960
375
405
1480*890*1960
490
520
510
540
1750*890*1960
750
790
790
830
2490*890*1960
830
875
1080
1120
1130
1160
3095*890*2050
1220
1280
1420
1470
1510
1590
(1) Return air dry bulb temperature 24℃,RH50%,outdoor dry bulb temperature35℃, variable speed compressor is operating at economic speed;
(2) Return air dry bulb temperature 24℃,RH50%,inlet chilling water temperature 30℃, chilling water flow under standard condition, variable
speed compressor is operating at economic speed;
(3) Return air dry bulb temperature 24℃,RH50%,outdoor temperature 2℃, chilling water flow under standard condition.
12
OPTIMA-HD
OPTIMA-HD is one type of precision air conditioners with high density
cooling capacity by using chilled water, applicable to large and mediumsized data center and electronic equipment room. It has a wide range
cooling capacity, high operating reliability and stability, the density of cooling
capacity is up to 75kW/m2 which can save a lot of space in equipment room.
Equipped with EC fan, OPTIMA-HD has a high operating efficiency, precise
control of temperature +/- 1℃, relative humidity +/-5% which can assure the
reliable and stable environment of the data room.
There are three air flow schemes, up flow, down flow and front flow under
rise floor can be provide to different needs of equipment room. Easily
maintain from the front of the product.
OPTIMA-HD use chilled water as cooling resource for mechanical cooling or
free cooling. The system has the characteristics of simple structure, reliable
and save the operating expense .
OPTIMA-HD has two types: single circuit and dual circuits. Each circuit
of dual circuits can be redundancy each other or work simultaneously or
rotation between mechanical cooling and chilled water of free cooling.
Model
Circuit
Supply air scheme
Power source
Cooling capacity(1)
Water flow(1)
Water pressure drop(1)
Supply fan
Type
Qty. of fan
Air volume
Electric heater capacity
Humidification capacity
kW
m3/h
kPa
40B1
60B1
42.1
7.2
95
60.7
9.6
97
80B2 100B2 120B3 140B3 160B4 180B4 50D1 60D1 80D2 100D2 120D3 140D3
CW: single circuit
CWD: double circuit
O:Up flow; U:Down flow
U:Down flow
380V-3Ph-50Hz
380V-3Ph-50Hz
83.6 101.6 123.3 145.2 160.5 180.9 50.4 61.1 81.0 100.7 120.5 143.2
14.2 17.3 19.5 24.7 26.3 28.4
7.7
9.6
12.7 14.8 17.9 22.0
86
94
93.6 91.2 98.6 83.9 101.1 123.1 83.1 83.2 184.6 156.6
EC Centrifugal Fan
EC Centrifugal Fan
n.
1
1
2
2
3
3
3
3
1
1
2
2
3
3
m3/h 11700 12600 22600 23600 31800 32600 37200 37200 11600 12300 23600 22800 31200 33600
kW
9
9
13.5 13.5
18
18
18
18
9
9
13.5 13.5 13.5 13.5
Kg/h
8
8
8
8
8
8
8
8
8
8
8
8
8
8
1250*900*1900
1750*900*1900
2560*900*1900
Width*Depth*Height(O/U)(2) mm 900*900*1960/1730 1750*900*1960/1730 2490*900*1960/1730 2905*900*1960/1730
Weight
Kg
375
405
525
560
670
750
840
910
380
405
465
490
580
640
(1) Return air dry bulb temperature 24℃,RH50%,inlet/outlet chilled water temperature 7℃/12℃;
(2) Excluding the height of return air plenum of up flow unit and supply air plenum of down flow unit.
13
DATACOOL
DATACOOL Precision air conditioning units are widely applied in small/medium
data center and computer rooms. DADATCOOL unit adopts new technologies,
using efficient compressor and fans and optimizing refrigerating system
configuration, to achieve its high efficiency and reliability, realizing COP >2.9,
temperature control accuracy <±1℃ while humidity control accuracy <±5%.
The compact structure and light weight makes easy installation. The unit can be
fully maintained from the front, greatly reducing the maintenance cost.
DATACOOL unit is available in 4 different air flow scheme: front up flow, down flow,
displacement flow, top flow, offering more options for different customers.
Model
Supply air scheme
Power source
Cooling capacity(1)
Compressor
Supply fan
Qty. of fan
Air volume
Electric heater capacity
Humidification capacity
Air cooled condenser
Width*Depth*Height
Weight
5E1C0 7E1C0 13E1C0 7E1C1 10E1C1 13E1C1 15E1C2 18E1C2 22E1C3 25E1C3 30E1C3
O: up-front throw
O: up-front throw; U: Bottom Throw; DL: Replacement; TP: top throw
380V-3Ph-50Hz
5.8
7.4
13.2
7.6
10.7
13.6
15.4
18.3
22.2
25.4
30.2
Rotor
Hermetic Scroll
n.
m3/h
kW
Kg/h
1
1650
2.3
3
1
1650
2.3
3
1
2630
4.5
3
1
2450
2.3
3
1
2450
4.5
3
1
2950
4.5
3
1
3450
6
5
1
3450
6
5
2
5100
9
5
CMD3*1 CMD4*1 CMD5*1 CMD4*1 CMD4*1 CMD5*1 CME5*1 CME8*1 CME8*1
mm
Kg
650*580*1910
120
135
155
650*650*1910
142
165
180
900*750*1910
255
290
2
6500
9
8
2
6500
9
8
CME10*1
CME10*1
1300*750*1910
370
460
490
(1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃.
DATACOOL-PACKAGE
DATACOOL-PACKAGE air conditioner with built-in fresh air free cooling system
is specially designed for small/medium data center and electronic equipment
room. Due to its proper working logic and standard EC supply fan, DATACOOLPACKAGE can maximum works in free cooling mode with the lowest power
consumption, saving huge energy and lowering the operation cost.
DATACOOL-PACKAGE is a self-contained air conditioning unit which realizes
easy installation without any refrigeration piping connection. The unit can be fully
maintained from the front, greatly reducing the maintenance cost as well.
DATACOOL-PACKAG is available in 2 different air flow schemes: up flow and down
flow, offering more options for different customers to increase its application flexibility.
Model
Supply air scheme
Power source
Cooling capacity(1)
Free cooling capacity(2)
Compressor
Evaporator fan
Type
Qty. of fan
Air volume
Condenser fan
Type
Qty. of fan
Air volume
Electric heater capacity
Width*Depth*Height(packaged unit)
Width*Depth*Height(split unit)
Weight (packaged unit)
Weight (split unit)
14
8E1A1
kW
kW
9.1
13.1
n.
m3/h
1
4350
n.
m3/h
kW
mm
Kg
Kg
15E1A1
22E1A2
O:Up flow; U:Down flow
380V-3Ph-50Hz
16.5
23.9
18.5
25
Hermetic Scroll Type
EC Centrifugal Fan
1
1
6150
8320
30E2A2
45E2A3
33
27.5
48.6
50
1
9150
2
16640
EC Centrifugal Fan
1
1
1
2
4200
5100
5800
10200
4.5
4.5
4.5
6
1160*1050*2350
1460*1100*2350
1160*1050*2450
1460*1100*2450
450
520
610
660
500
570
680
730
(1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃;
(2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃.
4
14400
9
2920*1100*2350
2920*1100*2450
1280
1420
MOBILECOOL-OUTDOOR
MOBILECOOL-OUTDOOR is a package type telecommunication base station
special air conditioner and designed for telecommunication base station, small
electronic equipment room. The unit features including good structure, easy
maintenance, high sensible ratio, high efficiency, and high reliability. The air
supplied from the front lower portion of the unit, which conforms with the air
flow rules well, making the heat exchange more efficiency.
MOBILECOOL-OUTDOOR uses EC fan supplied with alternating current
(direct current is optional). The unit is available in single or dual-control,
supplying various running strategies. The free cooling function is standard
configuration, saving the energy consumption highly.
MOBILECOOL-OUTDOOR installed in the outside of the shelter. The
installation type can save the space of shelters.
Model
Supply air scheme
Power source
Cooling capacity(1)
Free cooling capacity(2)
Compressor
Evaporator fan
Type
Air volume
Condenser fan
Type
Air volume
Width*Depth*Height
Weight
3R1C1
5E1C1
kW
kW
3.5
3.4
Rotory
5
4.0
m3/h
1000
m3/h
mm
Kg
3400
1200
7E1C2 10E1C2
DL:Replacement
230V-1Ph-60Hz
8.1
10
7.1
8.2
Scroll
13E1C3
18E1C4
7E1C2
13.4
8.9
17.8
12.9
8.1
7.1
EC Centrifugal Fan
2120
2460
2650
3850
2120
10E1C2 13E1C3
DL:Replacement
230V-3Ph-60Hz
10
13.4
8.2
8.9
Scroll
EC Centrifugal Fan
2460
2650
Axial
3400
620*620*1930
135
145
5000
17.8
12.9
3850
Axial
6300
930*700*2139
235
18E1C4
240
6300
8200
1080*700*2139 1280*700*2139
280
320
5000
6300
930*700*2139
235
240
6300
8200
1080*700*2139 1280*700*2139
280
320
Model
3R1C1 5E1C1 7E1C2 10E1C2 13E1C3 18E1C4 5E1C1 7E1C2 10E1C2 13E1C3 18E1C4
Supply air scheme
DL:Replacement
DL:Replacement
Power source
220V-1Ph-50Hz
380V-3Ph-50Hz
Cooling capacity(1)
kW
3.5
5.2
7.5
10.8
13.4
17.5
5.2
7.5
10.8
13.4
17.9
Free cooling capacity(2) kW
3.4
4.0
7.1
8.2
8.9
12.9
4.0
7.1
8.2
8.9
12.9
Compressor
Rotory
Scroll
Scroll
Evaporator fan
Type
EC Centrifugal Fan
EC Centrifugal Fan
Air volume
m3/h 1000 1200
2120
2460
2650
3850
1200 2120
2460
2650
3850
Condenser fan
Type
Axial
Axial
Air volume
m3/h 3200
3200
4200
5800
5800
7500
3200
4200
5800
5800
7500
620*620*1930
930*700*2139
1080*700*2139 1280*700*2139 620*620*1930
930*700*2139
1080*700*2139 1280*700*2139
Width*Depth*Height
mm
Weight
Kg
135
145
235
240
280
320
145
235
240
280
320
(1) Return air dry bulb temperature 27℃、RH50%,Outdoor dry bulb temperature35℃;
(2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃.
15
MOBILECOOL-INDOOR
MOBILECOOL-INDOOR is a package type telecommunication base station
special air conditioner and designed for telecommunication base station,
small electronic equipment room. The unit features including good structure,
easy maintenance, high sensible ratio, high efficiency, and high reliability.
The air supplied from the front lower portion of the unit, which conforms with
the air flow rules well, making the heat exchange more efficiency.
MOBILECOOL-INDOOR uses EC fan supplied with alternating current
(direct current is optional). The unit is available in single or dual-control,
supplying various running strategies. The free cooling function is standard
configuration, saving the energy consumption highly.
MOBILECOOL-INDOOR installed in the inside of the shelter. The installation
type is anti-theft, protecting the air conditioner from bad environment.
Model
Supply air scheme
Power source
Cooling capacity(1)
kW
Free cooling
kW
capacity(2)
Compressor
Evaporator fan
Type
Air volume
m3/h
Condenser fan
Type
Air volume
m3/h
Width*Depth*Height mm
Weight
Kg
Model
Supply air scheme
Power source
Cooling capacity(1)
Free cooling
capacity(2)
Compressor
Evaporator fan
Type
Air volume
Condenser fan
Type
Air volume
Width*Depth*Height
Weight
3R1D0
5E1D1
3.4
5
3.4
4.0
7E1D2
10E1D3
DL:Replacement
230V-1Ph-60Hz
7.9
9.8
7.1
Rotory
8.2
7E1D2
13.2
7.9
8.9
7.1
10E1D3
13E1D4
DL:Replacement
230V-3Ph-60Hz
9.8
13.2
8.2
Scroll
EC Centrifugal Fan
2120
2460
1000
1200
2400
2800
Centrifugal Fan
2800
500*600*2000
600*600*2000
130
160
3R1D0
5E1D1
kW
3.4
5.2
kW
3.4
4.0
EC Centrifugal Fan
2460
2650
2650
2120
4200
5600
2800
Centrifugal Fan
4200
5600
750*650*2100
860*650*2100
1010*650*2100
750*650*2100
860*650*2100
1010*650*2100
200
255
290
200
255
290
7E1D2
10E1D3
DL:Replacement
220V-1Ph-50Hz
7.4
10.6
7.1
Rotory
8.2
13E1D4
5E1D1
13.3
5.2
8.9
4.0
7E1D2
10E1D3
DL:Replacement
380V-3Ph-50Hz
7.4
10.6
7.1
Scroll
8.2
1000
1200
EC Centrifugal Fan
2120
2460
2650
1200
EC Centrifugal Fan
2120
2460
m3/h
mm
Kg
2400
2800
Centrifugal Fan
2800
4200
5600
2800
Centrifugal Fan
2800
4200
500*600*2000 600*600*2000 750*650*2100 860*650*2100 1010*650*2100 600*600*2000 750*650*2100 860*650*2100
160
200
13E1D4
13.3
8.9
Scroll
m3/h
130
8.9
Scroll
255
290
(1) Return air dry bulb temperature 27℃,RH50%,Outdoor dry bulb temperature35℃;
(2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃.
16
13E1D4
160
200
255
2650
5600
1010*650*2100
290
MOBILECOOL-SPLIT
MOBILECOOL-SPLIT is a spilt type telecommunication base station special air
conditioner and designed for telecommunication base station, small electronic
equipment room. The unit features including good structure, easy maintenance,
high sensible ratio, high efficiency, and high reliability. The air supplied from the
front lower portion of the unit, which conforms with the air flow rules well, making
the heat exchange more efficiency.
MOBILECOOL-SPLIT uses AC fan supplied with alternating current (direct
current is optional). The unit is available in single or dual-control, supplying
various running strategies. The free cooling function is optional, saving the
energy consumption highly.
Model
Supply air scheme
Power source
Cooling capacity(1)
Free cooling capacity(2)
Compressor
Supply fan
Type
Air volume
Width*Depth*Height
Weight
Condenser unit
Model
Width*Depth*Height
Weight
5R1D1
kW
kW
7R1D1
220V-1Ph-50Hz
5.5
7.6
5.9
5.9
Hermetic Rotary Type
10E1D2
13E1D2
O:Up flow; DL: Replacement
380V-3Ph-50Hz
10.4
13.3
7.4
11.6
Hermetic Scroll Type
15E1D2
14.9
11.6
m3/h
mm
kg
1800
600*500*1700
70
AC Centrifugal Fan
1800
2250
600*500*1700
750*500*1700
80
150
3500
750*500*1700
160
750*500*1700
165
mm
kg
CMD3
808*509*789
29
CMD4
808*509*789
35
CMD5
1004*509*930
43
CMD6
1250*509*930
92
CMD4
808*509*789
35
3500
(1) Return air dry bulb temperature 27℃,RH50%,Outdoor dry bulb temperature35℃;
(2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃(only for DL air supply scheme unit).
17
METROCOOL
METROCOOL unit is specially designed for industry environment, standing
up to high temperature, heavy pollution and continuous working demand and
offering high efficiency, strict fire proofing, various power supplies and widely
working condition with high reliability.
METROCOOL is a split air conditioning unit with rational structure for
convenient maintenance.
Electrical heaters with different capacity are available for this unit as options
to satisfy different application requirement.
Model
Power source
Cooling capacity(1)
Unit max. operating power input
Unit max. operating current
Indoor unit
Fan type
Air volume
Width*Depth*Height
Weight
Outdoor unit
Compressor
Fan type
Width*Depth*Height
Weight
Piping connection
Condensing water drainage
Refrigerant liquid
Refrigerant gas
MTC.5
kW
kW
A
m3/h
mm
Kg
MTC.7 MTC.10 MTC.13 MTC.5 MTC.7 MTC.10 MTC.13 MTC.5 MTC.7 MTC.10 MTC.13
380V-3Ph-50Hz
220V-1Ph-50Hz
208~230V-1Ph-60Hz
7.3
10.0
13.0
5.2
7.3
10.0
13.0
5.0
6.8
10.7
13.0
3.9
5.3
6.5
3.4
4.0
5.5
6.5
2.9
3.8
5.3
6.8
9.5
12.2
16.5
14.7
18.9
27.0
24.6
13.1
16.6
24.8
31.2
5.2
3.2
8.0
Double Inlet Centrifugal Fan
1400
1400
1600
2000
Double inlet Centrifugal Fan
1400
1400
1600
2000
Double inlet Centrifugal Fan
1400
1400
1600
2000
1295*280*680
1295*310*870
1295*280*680
1295*310*870
1295*280*680
1295*310*870
52
64
52
64
52
64
54
67
Hermetic scroll type
Axial flow fan
54
67
Hermetic scroll type
Axial flow fan
54
67
Hermetic scroll type
Axial flow fan
mm
Kg
91
95
123
145
91
95
123
145
91
95
123
145
mm
in
in
16
3/8″
1/2″
16
1/2″
5/8″
16
1/2″
3/4″
16
1/2″
3/4″
16
1/2″
5/8″
16
1/2″
5/8″
16
1/2″
3/4″
16
1/2″
3/4″
16
1/2″
5/8″
16
1/2″
5/8″
16
1/2″
3/4″
16
1/2″
3/4″
1260*590*880
1440*590*1125 1305*590*1500
1260*590*880
1440*590*1125 1305*590*1500
1260*590*880
1440*590*1125 1305*590*1500
(1) Top grade air flow, return air dry bulb temperature 27℃,wet bulb temperature 19℃,outdoor dry bulb temperature35℃, wet bulb temperature 24℃.
18
TELECOOL
Cabinet air condition is actively cooling with compressor, and it will remove the
heat inside the cabinet to outside. It also can keep the dust and heat outside the
cabinet, avoiding problems from using fan. The inside cabinet can be maintained
at an ideal temperature for electrical components which effectively guarantees
the stability of the electronic equipment and improves the reliability of the whole
system. The products can be widely used for outdoor communication cabinets,
battery cabinets, electric cabinets, industry control cabinets etc.
Model
Cooling Capacity(L35/L35)
Rated Power
Working Voltage
Working Temperature
Refrigerant
Noise
Ambient Air Circuit
Cabinet Air Circuit
Width*Depth*Height(R134a)
Width*Depth*Height(R22)
TC.AC.300 TC.AC.400 TC.AC.600 TC.AC.800 TC.AC.1000
W
W
300
220
400
240
600
365
800
460
dB
m3/h
m3/h
mm
mm
55
280
160
R134a
55
56
280
450
160
200
58
450
230
353*165*583
455*155*692
TC.AC.1200 TC.AC.1500
TC.AC.2000 TC.AC.2500 TC.AC.3000
1000
1200
1500
2000
490
610
685
830
220VAC±15% 50/60Hz
-40~55℃
R134a/R22
60
62
64
68
540
580
780
950
250
360
450
560
482*187*781 497*188*897 460*188*1087
/
482*187*781
497*188*897
2500
1020
3000
1240
68
1150
640
70
1380
780
549*220*1208
569*220*1308
460*188*1087
549*220*1208
(1) Return air dry bulb temperature 35℃,outdoor dry bulb temperature35℃.
Model
Cooling Capacity(L35/L35)
Rated Power
Working Voltage
Working Temperature
Refrigerant
Noise
Ambient Air Circuit
Cabinet Air Circuit
Width*Depth*Height
W
W
TC.DC.400
400~600
240
TC.DC1000
800~1000
450
TC.DC.2000
1500~2000
725
TC.DC.3000
2500~3000
1120
64
780
450
497*188*897
68
1380
780
549*220*1208
DC 48V
-40~55℃
R134a
dB
m³/h
m³/h
mm
55
450
200
455*155*692
60
540
250
482*187*781
(1) Return air dry bulb temperature 35℃,outdoor dry bulb temperature35℃.
19
FREECOOL-HD
FREECOOL-HD intelligent ventilation unit is applied in small/medium data center
and electronic equipment room. The unit introduces outdoor fresh air with lower
temperature to cool equipment room.
By using the FREECOOL-HD unit, the running hours of other air conditioning units
can be highly reduced, achieving power energy saving around 30~90%.
The FREECOOL-HD unit using EC fans can adjust the air volume automatically
according to the temperature difference with the lowest power consumption.
FREECOOL-HD without refrigeration system realizes easy installation and
convenient maintenance. The unit is available in 2 different air flow schemes: up
flow and down flow, and 2 installation positions: outdoor and indoor, offering more
options for different customers.
Model
Supply air scheme
Air volume
Air volume
Cooling capacity
△t=5℃
△t=10℃
△t=12℃
Power source
Fan
Type
Qty. of fan
Input power
Current
Width*Depth*Heigh
Weight
20
m3/h
m3/s
kW
kW
kW
n.
kW
A
mm
kg
24F1
48F2
2400
0.67
4750
1.3
4.0
7.9
8.0
15.8
9.6
19
230V/1/(50/60Hz)
1
0.5
3.1
700*450*1320
65
72F1
O/U
7200
2.0
144F2
216F3
14400
4.0
21600
6.0
12.0
24.0
28.8
24.0
48.0
57.6
400V/3/(50/60Hz)
36.0
72.0
86.4
Single inlet backward curved centrifugal fan
2
1
2
1.0
2.1
4.2
6.1
3.2
6.4
1150*450*1320
850*800*1770
1650*800*1770
89
150
260
3
6.3
9.4
2450*800*1770
350
FREECOOL
FREECOOL intelligent ventilation unit is applied in shelters and small equipment
room. The unit introduces outdoor fresh air with lower temperature to cool
equipment room. By using the FREECOOL unit, the running hours of other air
conditioning units can be highly reduced, achieving power energy saving around
30~90%.The FREECOOL DC series using EC fans can adjust the air volume
automatically according to the temperature difference with the lowest power
consumption.
FREECOOL is able to control up to 2 air conditioners. The unit is available in
various installation positions: outdoor and indoor, packaged and split, offering
more options for different data centre.
Model
Structure type
Cooling capacity
△t=5℃
kW
△t=10℃
kW
△t=12℃
kW
Power source
Fan
Type
Qty. of fan
n.
Air volume
m3/h
Input power(48VDC)
kW
Input power(220VAC)
kW
Width*Depth*Height(ID) mm
Width*Depth*Height(OD) mm
Weight(ID)
Kg
Weight(OD)
Kg
12F1
18F1
24F1
30F2
ID/OD Package
35F2
1.7
2.4
3.4
4.4
5
3.1
4.8
6.8
8.7
9.9
3.8
5.7
8.1
10.5
11.9
48VDC;220VAC (Only available for ID installation unit)
Single inlet backward curved centrifugal fan
1
1
1
2
2
1000
1450
2050
2650
3000
0.06
0.19
0.22
0.3
0.4
0.13
0.18
0.39
0.36
0.5
650*500*1100
750*600*1400
650*500*1320
750*630*1620
60
60
65
85
85
65
65
68
115
115
12F1
18F1
24F1
ID/OD Split
30F1
35F1
1.7
2.9
3.4
5
5.7
3.3
5.8
6.8
10
11.4
4
6.9
8.1
12
13.7
48VDC;220VAC (Only available for ID installation unit)
Single inlet backward curved centrifugal fan
1
1
1
1
1
1000
1750
2050
3030
3450
0.06
0.19
0.23
0.26
0.39
0.13
0.18
0.39
0.38
0.57
550*450*700
600*500*900
550*550*600
610*610*630
40
40
42
48
50
38
38
40
45
45
21
Outdoor condenser and dry cooler
The covers of CME air-cooled condenser are produced by aluminum sheet,
which has characteristics of light weight, Anti-corrosion, anti-rust, etc. The
condenser is equipped with adjustable speed axial fan and high efficiency
heater exchanger. Vertical or horizontal installation of the condenser is
available.
The covers of AMAE air-cooled condenser are produced by aluminum sheet,
which has characteristics of light weight, anti-corrosion, anti-rust, etc. The
condenser is equipped with EC axial fan which has characteristics of big
air volume, lower power consumption and adjustable fan speed and high
efficiency heater exchanger. The condenser is suitable for high temperature
working conditions. Vertical or horizontal installation of the condenser is
available.
CMD air-cooled condenser is used for small precision air conditioner or
base station air conditioner. The covers of CMD condenser are produced
by coating sheet metal, which has characteristics of anti-corrosion, anti-rust,
etc. The condenser is equipped with adjustable speed axial fan and high
efficiency heater exchanger. Only vertical installation of the condenser is
available.
The covers of CMEH dry cooler are produced by aluminum sheet, which has
characteristics of light weight, Anti-corrosion, anti-rust, etc. The condenser
is equipped with adjustable speed axial fan and high efficiency heater
exchanger. Vertical or horizontal installation of the condenser is available.
CMD/CME
Model
Power source
Capacity (1)
Fan
Qty. of fan
Air volume
Input power
Input current
Gas pipe
Liquid pipe
Width*Depth*Height
Weight
CMD3
CMD4
CMD5
CMD6
CME4
kW
9.3
13.7
20.4
23.6
15.6
n.
m3/h
kW
A
ODF
ODF
mm
Kg
1
4400
0.28
1.3
5/8"
1/2"
1
4100
0.28
1.3
5/8"
1/2"
1
5600
0.37
1.7
5/8"
1/2"
1
5800
0.37
1.7
5/8"
1/2"
1
4400
0.28
1.3
16
12
808*509*789
29
35
CME5
CME8
220V-1Ph-50Hz
20.5
29.6
1
5600
0.37
1.7
19
12
1004*509*930 1250*509*930 840*475*770 1140*475*770
43
92
37
47
(1) Heat dissipating capacity @ inlet air temperature 35℃, condensation temperature 50℃.
22
1
10100
0.63
3
22
16
CME10
CME15
35.4
47.6
67.4
73.1
1
9700
0.63
3
22
16
2
11600
0.74
3.4
22
19
2
20100
1.26
6
28
19
2
19100
1.26
6
35
22
1340*620*1070
95
110
1540*620*1070
130
CME20 CME25
2400*630*1135
155
185
AMAE
Model
Power source
Capacity (1)
Fan
Qty. of fan
Air volume
Input power
Input current
Gas pipe
Liquid pipe
Width*Depth*Height
Weight
AMAE5
AMAE6
AMAE8
kW
24.2
29.7
36.2
n.
m3/h
kW
A
ODF
ODF
mm
Kg
1
12500
0.63
2.8
19
16
1
11600
0.63
2.8
19
16
1
11800
0.63
2.8
19
16
1365*620*1080
103
116
AMAE10
AMAE12
220V/1Ph/50Hz
41.3
50.7
1
11500
0.63
2.8
22
16
2
23500
1.26
5.6
22
16
1665*620*1080
135
AMAE15
AMAE18
AMAE20
57.2
62.4
74.3
2
22000
1.26
5.6
22
16
2
23400
1.26
5.6
22
19
2
22600
1.26
5.6
28
19
1985*620*1080
152
173
182
2790*620*1080
206
220
(1) Heat dissipating capacity @ inlet air temperature 35℃, condensation temperature 50℃.
CMEH
Model
Power source
Capacity
Heat exchange coil
Water flow
Pressure drop
Fan
Qty. of fan
Air volume
Nominal mechanical power
Max electric absorption
Width*Depth*Height
Weight
CMEH20
CMEH30
kW
23.2
31.2
m3/h
3.5
71.1
5.2
68.2
kPa
n.
m3/h
kW
A
mm
Kg
1
1
12100
11200
0.75
0.75
3.3
3.3
1350*620*1070
95
115
CMEH40
CMEH50
220V/1Ph/50Hz
45.3
56.7
6.2
58.7
2
22800
1.5
6.6
1980*620*1120
145
9.3
57.6
CMEH60
CMEH70
CMEH80
61.5
75.2
83.1
10.2
69.1
10.6
72.3
11.8
78.5
2
2
23200
21800
1.5
1.5
6.6
6.6
2700*620*1120
175
195
3
3
33600
32400
2.3
2.3
10.1
10.1
3580*620*1120
235
255
(1) Heat dissipating capacity @ inlet air temperature 35℃, inlet water temperature 45℃.
23
CRITICOOL/CRITICOOL-FC
CRITICOOL series is applicable to large-sized data center and all kinds of
industrial technology place. It has a wide range cooling capacity, high operating
reliability and stability. CRITICOOL-FC is equipped with additional chilled water
coil, free cooling system will be used when outdoor temperature is low enough,
minimize the run time of mechanical cooling and save huge energy and lowering
the operation cost.
CRITICOOL adopts screw compressor, offer built-in pump group as option, the
customer only need to connect water pipe and power supply cable on the site.
Outdoor installation, no room occupied.
Standard
Model
Cooling capacity(1)
Heating capacity(2)
Qty of compressor
Heating capacity of partial heat
recycle(Option)(3)
Length
Width
Height
Weight (4)
(1)
(2)
(3)
(4)
kW
kW
n.
130V1
115
128.8
1
150V1
138
154.6
1
200V1
178
199.4
1
250V1
245
274.4
1
350V1
315
356
1
400V1
377
422.2
1
450V1
408
457
1
500V1
475
532
1
400V2
370
414.4
2
450V2
420
470.4
2
700V2
630
711.9
2
800V2
754
844.5
2
kW
34
41
56.8
80.5
103.7
120.3
122.4
142.5
118
126
198
216.7
mm
mm
mm
kg
3600
1290
2280
1640
3600
1290
2280
1780
4335
1290
2280
1910
5170
1290
2280
2350
4980
2130
2540
3425
4980
2130
2540
3800
4980
2130
2540
3880
6490
2130
2540
4850
4980
2130
2540
3960
6490
2130
2540
4900
7480
2130
2540
6250
8470
2130
2540
7000
Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃;
Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃;
The inlet temperature of heat recycle 40℃;
Exclude the weight of option.
Compact type
Model
Cooling capacity(1)
Heating capacity(2)
Qty of compressor
Heating capacity of partial
heat recycle(Option)(3)
Length
Width
Height
Weight (4)
(1)
(2)
(3)
(4)
24
kW
kW
n.
700V2 750V2 800V2 890V2 950V2 1000V2 1100V2 1200V2 900V3 1000V4 1200V4 1400V4 1500V4 1600V4
630
692
754
816
883
942
1033
1124
880
996
1126
1256
1390
1508
712
778
844
914
991
1066
986
1118
1261
1407
1557
1689
2
2
2
2
2
2
2
2
3
4
4
4
4
4
kW
189
207.6
226.2
244.8
264.9
282.6
309.9
337.2
264
320.4
396
396
448
481.2
mm
mm
mm
kg
6450
2350
2600
6760
6750
2350
2600
7080
7050
2350
2600
7400
7050
2350
2600
7650
8130
2350
2600
8190
9210
2350
2600
9260
10290
2350
2600
10280
11370
2350
2600
11300
8710
2350
2600
9520
10780
2350
2600
11920
11340
2350
2600
12740
12900
2350
2600
13520
13500
2350
2600
14160
14100
2350
2600
14800
Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃;
Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃;
The inlet temperature of heat recycle 40℃;
Exclude the weight of option.
Standard free cooling type
Model Cooling capacity(1)
Cooling capacity(2)
Free cooling capacity(3)
Qty. of compressors
Length
Width
Height
Weight
Model
Cooling capacity(1)
Cooling capacity(2)
Free cooling capacity(3)
Qty. of compressors
Length
Width
Height
Weight
(1)
(2)
(3)
(4)
kW
kW
kW
n.
mm
mm
mm
kg
kW
kW
kW
n.
mm
mm
mm
kg
350V1
312
346
348
1
3410
2350
2600
3780
800V2
746
829
833
2
7050
2350
2600
8350
400V1
373
414
416
1
3710
2350
2600
4140
890V2
808
897
901
2
7050
2350
2600
8590
450V1
404
448
451
1
3710
2350
2600
4305
950V2
874
970
975
2
8130
2350
2600
9270
500V1
470
522
525
1
4790
2350
2600
5130
1000V2
931
1034
1039
2
9210
2350
2600
11320
600V1
557
619
622
1
5870
2350
2600
6240
1200V2
1115
1237
1244
2
10290
2350
2600
13300
700V2
624
692
696
2
6450
2350
2600
7560
1400V2
1271
1411
1418
2
11370
2350
2600
14100
750V2
685
760
764
2
6750
2350
2600
7880
1600V2
1493
1657
1665
2
14100
2350
2600
16000
Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃;
Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃;
The inlet temperature of heat recycle 40℃;
Exclude the weight of option.
Low noise free cooling type
Model Cooling capacity(1)
Cooling capacity(2)
Free cooling capacity(3)
Qty. of compressors
Length
Width
Height
Weight
kW
kW
kW
n.
mm
mm
mm
kg
Model Cooling capacity(1)
Cooling capacity(2)
Free cooling capacity(3)
Qty. of compressors
Length
Width
Height
Weight
kW
kW
kW
n.
mm
mm
mm
kg
(1)
(2)
(3)
(4)
130V1
114
126
127
1
3600
1420
2280
1840
400V2
366
407
409
2
4980
2370
2540
4760
150V1
137
152
152
1
3600
1420
2280
1980
450V2
416
462
464
2
6490
2370
2540
5900
200V1
176
196
197
1
4355
1420
2280
2210
500V2
497
552
554
2
6490
2370
2540
6160
250V1
243
269
271
1
5170
1420
2280
2550
600V2
557
619
622
2
7480
2370
2540
7260
350V1
312
346
348
1
4980
2370
2540
3725
700V2
624
692
696
2
7480
2370
2540
7550
400V1
373
414
416
1
4980
2370
2540
4250
450V1
404
448
451
1
4980
2370
2540
5400
800V2
746
829
833
2
8470
2370
2540
8500
500V1
470
522
525
1
6490
2370
2540
5660
1000V2
941
1044
1049
2
13780
2370
2540
11320
600V1
557
619
622
1
7480
2370
2540
6650
1200V2
1115
1237
1244
2
15760
2370
2540
13300
700V1
636
705
709
1
7480
2370
2540
7050
1400V2
1271
1411
1418
2
15760
2370
2540
14100
800V1
746
829
833
1
8470
2370
2540
8000
1600V2
1493
1657
1665
2
18440
2370
2540
16000
Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃;
Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃;
The inlet temperature of heat recycle 40℃;
Exclude the weight of option.
25
HYDROCOOL
HYDRCOOL/HYDROCOO-HE series is applicable to large-sized data
center and all kinds of industrial technology place. It has a wide range
cooling capacity, high operating reliability and stability. HYDROCOO-HE
is equipped with flooded evaporator, to achieve higher EER, save huge
energy and lowering the operation cost.
This series adopts screw compressor and flooded evaporator, minimized
the unit size and footprint.
Standard
Model
Cooling capacity (1)
Cooling capacity (2)
Heating capacity (3)
Qty of compressor
Heating capacity of
partial heat recycle
Length
Width
Height
Weight (4)
Model
Cooling capacity (1)
Cooling capacity (2)
Heating capacity (3)
Qty of compressor
Heating capacity of
partial heat recycle
Length
Width
Height
Weight (4)
250V1
229.5
238.2
237.5
1
kW
kW
kW
n.
400V1
406.7
422.2
421.6
1
500V1
495.1
513.9
511.3
1
600V1
589.7
612.1
611
1
700V1
736.5
764.5
763
1
500V2
459
476.4
475
2
800V2
804.6
835.2
835.8
2
900V2 1000V2 1100V2
894.7
989.8
1076
928.7 1027.4 1116.9
927.1 1021.6 1115.5
2
2
2
1200V2 1300V2
1175.6 1320
1220.3 1370.2
1218.7 1369.1
2
2
kw
52.9
86.1
104.1
134.1
160
103.9
172.5
192.1
209.4
227.6
248.7
279.3
mm
mm
mm
kg
3385
970
2000
1380
3385
970
2000
2000
3385
1060
2000
2320
3415
1060
2000
3110
3475
1060
2000
3280
3900
1160
1940
2400
4100
1160
2100
3610
4160
1160
2100
3740
4160
1160
2100
3820
4160
1300
2160
4100
4160
1540
2160
4600
4450
1540
2214
4750
kW
kW
kW
n.
1400V2
1470.5
1526.4
1523.1
2
1600V2
1612.3
1673.6
1669.8
2
1800V2
1820.6
1889.8
1888.1
2
1600V4
1609.2
1670.3
1671.5
4
1800V4
1789.4
1857.4
1854.1
4
3200V4
3224.6
3347.1
3339.6
4
3600V4
3641.2
3779.6
3776.1
4
kW
311
338.6
382.3
345
381.7
418.9
455.2
535.6
582.9
635.1
677.2
764.6
mm
mm
mm
kg
4510
1540
2214
4900
4510
1540
2214
5300
4510
1540
2214
5500
4100
2560
2100
7220
4160
2560
2100
7480
4160
2560
2100
7640
4160
2840
2160
8100
4160
3320
2160
9000
4450
3320
2214
9305
4510
3320
2214
9600
4510
3320
2214
10600
4510
3320
2214
11000
2000V4 2200V4 2400V4 2600V4 2800V4
1979.6 2125 2357.9 2644.5 2938
2054.8 2233.8 2447.5 2745 3049.6
2043.1 2231 2442.7 2740.3 3043.7
4
4
4
4
4
Full liquid Type
Model
Cooling capacity (1)
Cooling capacity (2)
Heating capacity (3)
Qty of compressor
Heating capacity of
partial heat recycle
Length
Width
Height
Weight (4)
Model
Cooling capacity (1)
Cooling capacity (2)
Heating capacity (3)
Qty of compressor
Heating capacity of
partial heat recycle
Length
Width
Height
Weight (4)
300V1 340V1 400V1
kW 274.3 321.8 379.3
kW 289.6 339.6 400.3
kW 296.2 348.1 409.9
n.
1
1
1
450V1
443.3
468.4
475.7
1
500V1 550V1 600V1 650V1 700V1 800V1 600V2 700V2
502.1 556 581.9 656
720 757.8 548.5 643.5
530.4 587.6 614.7 692.9 761.4 801.4 579.1 679.3
537.7 596.6 624.3 702
755 793.5 592.4 696.3
1
1
1
1
1
1
2
2
kw
68.6
80.4
94.8
110.8 125.5
139
145.5
164
180
189.5 137.1 160.9 189.7 221.7
251.1
mm
mm
mm
kg
3555
1160
1630
2350
3555
1160
1630
2500
3555
1160
1630
2780
3570
1240
1880
3060
3970
1240
1880
3435
3985
1280
1880
3740
3985
1320
2070
3940
3995
1380
2070
4060
3995
1380
2070
4210
4470
1440
1990
6260
kw
kw
kw
n.
1100V2
1111.9
1175.1
1193.1
2
kw
278
290.9
328
360
378.9
443.3
502.1
556
581.9
656
720
757.8
mm
mm
mm
kg
4485
1540
2040
6950
4485
1540
2040
7410
4485
1590
2180
7810
4495
1640
2230
8020
4495
1640
2230
8350
4470
2950
2480
11900
4470
2950
2540
12520
4485
2950
2640
13900
4485
2950
2710
14820
4495
2950
2760
15620
4495
2950
2780
16040
4495
2950
2780
16700
3770
1240
1880
3200
4445
1240
1670
4435
4445
1240
1670
4720
800V2
758.6
800.6
819.7
2
4460
1320
1720
5530
900V2
886.7
936.9
951.5
2
4460
1380
1930
5950
1000V2
1004.3
1060.7
1075.4
2
1200V2 1300V2 1400V2 1600V2 1800V2 2000V4 2200V4 2400V4 2600V4 2800V4 2000V4
1163.7
1312
1440
1515.6 1773.3 2008.5 2223.8 2327.5
2624
2880
3031.2
1229.3 1385.8 1522.8 1602.8 1873.7 2121.5 2350.2 2458.7 2771.6 3045.6 3205.6
1248.7 1404.1
1510
1587
1902.9 2150.8 2386.2 2497.3 2808.1
3020
3174
2
2
2
2
4
4
4
4
4
4
4
(1) Cooling capacity @ evaporator water inlet and outlet temperature 12/7℃, condenser water inlet and outlet temperature 30/35℃;
(2) Water source heating pump cooling capacity @ evaporator water inlet and outlet temperature 12/7℃, condenser water inlet and outlet temperature 15/30℃;
(3) Water source heating pump heating capacity @ evaporator water inlet and outlet temperature 15/6℃, condenser water inlet and outlet temperature 40/45℃;
26
(4) Exclude the weight of option.
Control system
All AIRSYS products are equipped with AIRSYS advanced
By running status and time records, you can keep
microcomputer control system. Hardware meets industrial /
abreast of the operational status of the unit, part of the
ICT environment requirements, high reliability, anti-jamming.
on / off status, running time and other information.
Control program embodies AIRSY many years’ experience
in ICT environment-air conditioner produce, fully consider
reliable, energy saving, convenient needs, are the core
values embodied AIRSYS products.
Alarm and security alarm information and provide
numerous security protection, including restart, current
and voltage, phase sequence protection, pressure
protection, thermal protection, and so on.
By micro-controller, a large number of parameters can
be set flexibly, including automatic / manual, operating
logic selection, parameter calibration, the ON / OFF the
designated member.
There are several ways to achieve remote monitoring,
remote setting parameters, upload programs, remote
on / off, remote alarm, etc.
Remote Control And Monitoring Network
The unit can be remote controlled or monitored by many
kinds of methods as follows:
3 kinds of local direct cable connection
3 kinds of LAN network connection
4 kinds of wireless network connection
Local area network connection type
Wireless connection types
Cooling unit & Comm. card
LAN connection 1
wireless communication network
Wireless connection 1
N1
RS485 card
MODBUS protocol
345$1*1wireless router
RS485-TCP/IP converter with 16 ports
Ethernet network cable
RS485 Bus
N2
Wireless connection 2
Wireless router
Mobile phone
Wireless connection 3
The computer is installed with
TCP/IP cardˈRS485 cardˈ
RS232 card and IntelliVision plus
software
GSM Mobile communication network
N16
GSM module
N1
LAN connection 2
Wireless connection 4
Mobile phone
GSM module
&UIFSOFUOFUXPSLDBCMF
RS485 Bus
N2
Monitoring Computer
GSM communication network
N16
Single unit direct connection types
Direct connection 1
34%BUBDBCMF
Units direct connection type
N1
RS485-RS232 Converter
Direct connection 2
34%BUBDBCMF
RS485-RS232 Converter
RS232 cable
Direct connection 3
RS485 Bus
N2
34%BUBMJOF
Single port RS485-TCP/IP converter
Direct connection 4
&UIFSOFUOFUXPSLDBCMF
N16
27
Airsys Refrigeration Engineering Technology (Beijing) Co., Ltd.
28, Lu Gu Dong Jie, ShijingshanBeijing, China,100040
Tel:+86-10-6865 6161 Fax:+86-10-6865 2453
Gu'an Airsys Enviroment Technology Company Ltd.
P.25, St. West Orient, Gu'an Industry Park, Gu'an County, Langfang City, Hebei Province, China.
Tel:+86-10-6865 6161 Fax:+86-10-6865 2453
Shanghai Airserve HVAC Systerm Service Co., Ltd.
#7-2,No.658,Daduhe Rd.,Putuo District,Shanghai,China,200333
Tel: +86-21-6245 2626 Fax:+86-21-6245 9622
Airsys Group (HK) Co., Ltd.
Room 1305, Carnival Commercial Building, No. 18 Java Road, North Point,Hong Kong
Tel: 00852-2711 0511 Fax: 00852-2711 1511
Airsys (UK) Ltd.
Oak House Overbrook Lane Knowsley Business Park Liverpool,UK L34 9FB
Tel: +44-845 2411007 Fax: +44-151 547 8801
www.air-sys.com Callcenter:+86-400-820-5515
Download