AIRSYS-P-SC-GENERAL-E1408V01.5 AIRSYS Expert in ICT Cooling AIRSYS Refrigeration Engineering Technology (Beijing) Co.,Ltd Brief Introduction Airsys is a world major player in ICT cooling with a wide range of product including Precision Air-conditioner for computer room and data center, air-conditioner and Intelligent Free Cooling unit for BTS station, air-conditioner and heat exchanger for various type of cabinets, chillers for data center cooling source. All product is highly reliable and energy efficient. Airsys provide the full solution and service to its customer such as product selection, design and development, manufacturing, installation, after-sale service and contract operation. 1995 1999 2001 Founded in Beijing as the distributor Introduced Airsys Brand chiller and ISO9001 certified. Introduced of a major European ICT cooling become a HVAC manufacturer. Airsys Brand Precision Air- manufacturer, established the conditioner. national sales & distribution network. 2007 2008 2009 Obtained the record making New GuAnproduction facility Became global s shelter air-conditioner PO from completed, 30,000 sqm of covered supply various IC Reliance Communication, an plant and 80,000 sqm of total area, Indian telecom operation. became one of the leader in ICT Became strategic partner of cooling. China Mobile to develop the high “2008 Technology Innovation energy efficient air-conditioner for Award for Green Telecom China” its green shelter project. Became global supplier for Siemens Healthcare. 2 2003 2004 2006 Elected as “Best Employer” by New production facility in Beijing Attended the ITU exhibition and <Fortune> Chinese Edition. completed. started the strategic development of Became global supplier for the international market. GE Healthcare and got the “Technology Innovation Award” of the year. 2010 2011 supplier of Vodafone, The packaged outdoor shelter air- Became the global supplier for CT cooling products. conditioner passed the quality audit Phillips Healthcare and got well and on site energy efficiency test of acknowledged by the customer. Verizon Wireless, became a part of Became the global supplier of their new shelter HVAC standard. British Telecom, providing site Became its first Chinese supplier and survey, installation with the newly start the bunch supply. established Airsys UK. 3 Core Value Reliability Reliability means supplying reliable products and services and winning trusts from happy customers in order to win the market. Efficiency Efficiency means optimizing resource distribution to ensure sustainable business development and maximizing profit margins. Responsibility Responsibility means being responsible to shareholders, customers, employees, suppliers, and the society in large. Respect Respect means respecting to shareholders, customers, employees, suppliers and partners. Social Responsibility AIRSYS will always devote to fulfill the social responsibility of all aspects, providing more environment friendly products, protecting the sustainable development of global environment. Also,we contribute to the development of region and happiness, health and sustainable development of employees and their families. Vision A major global supplier of product and service in ICT and related industries. 4 Manufacturing Facility As the largest ICT cooling product manufacturing facility in Asia, Airsys GuAn has a total area of 80,000 sqm among which 30,000 sqm are covered plant. Equipped with production line for heat exchanger, sheet metal, powder painting, assembly line and performance test chamber, this facility can produce different type of ICT cooling product or more than 100,000 units a year. Energy Saving World is facing the challenge of energy shortage, especially in ICT industry,the revolution in information storage, processing and transmission result more and more energy consumption. Energy efficiency has always been the core value and responsibility of Airsys. We use various kind of technologies, such as free cooling chiller, air-conditioner, independent free cooling unit, EC fan, DC compressor, battery cooler, scroll compressor and displacement air distribution scheme, to help our customer to cut their energy bill High Reliability ICT environment cooling requires high reliability. Airsys has always taken reliability as the most important value and build into every aspect of our business process and every employee’s mind. We assure every product produced is highly reliable by selection of component, design validation, IE and QC, 100% test, process control on installation and service. Our product meet various international standard such as CE, UL, RoHS, CCC. Research and Development Our R&D team is formed by experienced HVAC AND electric engineers. Apart from the standard products, we have rich experience in developing custom made products for our customer. We can quickly deliver the technical proposal, prototype, laboratory performance test report and real site test according to customer’s requirement. Service Network Airsys has a well established service network throughout China and major international regions. Our team, call center and CRM platform provide fast and professional service covering installation, emergency intervention, maintenance, contract operation, online failure analysis, IAQ analysis. 5 Airsys and ICT Industry Telecom Operator – China Mobile Telecom Operator – Verizon Wireless Major Cooling Supplier Gone through 3 years of real site testing, highly recognized Strategic Partner for “Green Action Plan” by the customer for its reliability, energy efficiency and Research and consulting service on shelter cooling energy saving and related standard, developing the software for energy saving calculation, product. overall performance. Specified in the new Verizon Wireless Shelter standard. Become its first Chinese supplier. Supply CRAC for its large Data Center. Telecom Equipment Supplier- ZTE Telecom Operator – China Telecom Major Cooling Supplier Long Term Partner, supply CRAC for its large Data Center. Telecom Operator – Vodafone Global Cooling Supplier Jointly develop various cooling product with significant energy saving features. Long Term Partner Supply all range of product from Cabinet cooling to Data Center cooling. ICT Power Equipment Supplier-Delta, Eltek Strategic Partner Supply all range of cooling product from cabinet to data center. Help to improve both CAPEX and OPEX Data Center Operator, Internet Companies Telecom Operator – British Telecom Global Cooling Supplier Develop custom made cooling product. Provide turnkey solution including site survey, installation, and product supply. Telecom Operator –Reliance Communication Strategic Cooling Supplier Completed Design, Prototype and Pilot order within 3 months, delivered 25,000 units within 12 months period. The units have shown the best of its kind in terms of failure rate, energy consumption in the market of India. Won the Best Supplier Award in year 2007 and 2008. 6 Supply full solution for Data Center. Sales and service network Airsys Refrigeration Engineering Technology (Beijing) Co.,Ltd Gu'an Airsys Environmental Technology Co. Ltd Shanghai Airserve HVAC Systerm Service Co., Ltd. Technical Support and Logistic Center EU-CIS-India North America Middle East & Africa Airsys Group (HK) Co., Ltd. Airsys (UK) Ltd. Sales & Distribution Asia Pacific: India, Pakistan, Nepal, Australia, Singapore, Indonesia, Malaysia, Vietnam, Philipine EMEA: Russia, France, UK, Romania, Spain, Czek, Italy, Turkey, South Africa, Nigeria. Americas: USA, Canada, Mexico, Ecuador. 7 Airsys product &solutions Cabinet TELECOOL Cooling capacity:0.3~3kW Telecom Shelter MOBILECOOL-OUTDOOR Cooling capacity:3.5~17.9 kW Data Center OPTIMA.DXA/DXW Cooling capacity:17.6~106.7kW OPTIMA-FC.DXA/DXW Cooling capacity:17.6~106.7kW OPTIMA-INV.DXA/DXW Cooling capacity:16.3~115.4kW OPTIMA-FC-INV.DXA/DXW Cooling capacity:16.1~115.4kW OPTIMA.CW/CWD Cooling capacity:24.8~134.5kW Air- MOBILECOOL-INDOOR Cooling capacity:3.4~13.3 kW conditioner OPTIMA-HD.CW/CWD Cooling capacity:42.1~180.9 kW DATACOOL Cooling capacity:5.8~30.2 kW DATACOOL-PACKAGE Cooling capacity:9.1~48.6 kW Outdoor condenser and dry cooler Cooling capacity:9.3~83.1 kW MOBILECOOL-SPLIT Cooling capacity:5.5~14.9kW METROCOOL Cooling capacity:5.2~13.0kW Chiller CRITICOOL Cooling capacity:115~1508 kW HYDROCOOL Cooling capacity:229.5~3641.2 kW CRITICOOL-FC Cooling capacity:114~1493 kW Ventilation & Heat Exchanger FREECOOL Air flow: 1000~3450 m3/h 8 FREECOOL-HD Air flow: 2400~21600 m3/h OPTIMA/OPTIMA-INV OPTIMA family includes standard series of OPTIMA and DC inverter series of OPTIMA-INV, is applicable to large and medium-sized data center and electronic equipment room. It has a wide range cooling capacity, high operating reliability and stability. Equipped with EC fan, precise control of temperature ±1℃, relative humidity ±5% which can assure the reliable and stable environment of the data room. Standard series of OPTIMA has various type of cooling system, direct expansion with air-cooled condenser, direct expansion with water-cooled condenser, chilled water with either single coil or double coil. DC inverter series of OPTIMA-INV has two types of cooling schemes: direct expansion with air-cooled condensers, direct expansion with water-cooled condenser. There are up flow and down flow for supply air and up, down, front and back for return air to meet the different needs of equipment room. All units can be easily maintained from the front. Direct expansion air-cooled (DXA) work with CME or AMAE air-cooled condenser. Direct expansion water-cooled (DXW) work with CMEH dry cooler or central cooling tower and pumping group. OPTIMA.DXA/DXW Model Supply air scheme Power source Cooling capacity DXA(1) DXW(2) Compressor Supply fan Type Qty. of fan Air volume Electric heater capacity Humidification capacity Air cooled condenser(DXA) Width*Depth*Height DXA Weight DXW Weight 16E1A1 20E1A1 26E1A2 30E1A2 35E1A2 40E2A3 50E2A3 60E2A4 70E2A4 80E2A4 90E2A5 100E2A5 O:Up flow; U:Down flow 380V-3Ph-50Hz kW kW 18.9 17.6 22.0 21.5 28.5 27.9 31.9 31.2 37.6 36.1 n. m3/h kW Kg/h 1 5750 6 3 1 6320 6 3 1 8900 9 5 1 9600 9 5 1 9600 9 5 CME5*1 mm Kg Kg 46.6 55.1 65.3 45.8 57.2 62.1 Hermetic Scroll Type EC Centrifugal Fan 2 2 3 12600 13600 17800 13.5 13.5 18 8 8 8 74.5 72.2 84.6 82.3 90.7 90.4 103.4 106.7 3 19200 18 8 3 21000 18 8 3 24600 18 8 3 27900 18 8 CME8*1 CME10*1 CME10* CME15*1 CME8*2 CME10*2 CME10*2 CME15*2 CME15*2 CME20*2 CME20*2 875*890*1960 310 360 322 374 1480*890*1960 370 410 415 385 423 431 1750*890*1960 620 670 656 709 2490*890*1960 930 980 1020 971 1013 1076 3095*890*2050 1210 1250 1256 1300 (1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃; (2) Return air dry bulb temperature 24℃,RH50%,inlet condensing water temperature 30℃, standard water flow. 9 OPTIMA-INV.DXA/DXW Model Supply air scheme Power source Cooling capacity DXA(1) DXW(2) Compressor Supply fan Type Qty. of fan Air volume Electric heater capacity Humidification capacity Air cooled condenser(DXA) Dry cooler(DXW) Width*Depth*Height DXA Weight DXW Weight 16E1A1 22E1A2 30E1A2 35E2A3 45E2A3 55E2A3 60E2A4 70E2A4 80E2A4 90E2A5 110E2A5 O:Up flow; U:Down flow 380V-3Ph-50Hz kW kW 16.3 17.2 22.3 23.5 30.2 32.1 36.9 36.8 47.2 55.2 61.6 70.8 48.1 56.4 63.5 73.5 Hermetic DC Inverter Scroll Type n. Kg/h 1 5750 6 3 1 8900 9 5 1 9600 9 5 2 12600 13.5 8 EC Centrifugal Fan 2 2 3 12600 13600 17800 13.5 13.5 18 8 8 8 112.8 115.4 3 21000 18 8 3 24600 18 8 3 27900 18 8 AMAE6*1 AMAE8*2 AMAE10*2 AMAE12*2 AMAE15*2 AMAE18*2 AMAE20*2 Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2 875*890*1960 348 395 1480*890*1960 440 490 475 510 AMAE8*2 92.3 93.7 Model*n. mm Kg Kg AMAE8*1 AMAE10*1 AMAE6*2 3 19200 18 8 80.3 82.3 1750*890*1960 710 750 750 810 2490*890*1960 790 860 960 1080 1010 1130 3095*890*2050 1150 1250 1270 1430 1350 1540 (1) Return air dry bulb temperature 24℃,RH50%,outdoor dry bulb temperature35℃, variable speed compressor is operating at economicspeed; (2) Return air dry bulb temperature 24℃,RH50%, inlet condensing water temperature 30℃, water flow under standard condition, variable speed compressor is operating at economic speed . OPTIMA.CW/CWD Model Supply air scheme Power source Cooling capacity(1) Supply fan Type Qty. of fan Air volume Electric heater capacity Humidification capacity Width*Depth*Height CW Weight CWD Weight kW n. m3/h kW Kg/h mm Kg Kg 20A1 30A1 40A2 24.8 30.3 40.8 1 1 6750 6750 6 6 3 3 875*890*1960 310 335 327 356 45A2 55A3 65A3 80A4 O:Up flow; U:Down flow 380V-3Ph-50Hz 47.7 55.8 66.5 80.5 1 1 9600 9600 9 9 5 5 1480*890*1960 380 410 408 448 EC Centrifugal Fan 2 2 15300 15300 13.5 13.5 8 8 1750*890*1960 470 510 504 556 (1) Return air dry bulb temperature 24℃,RH50%,inlet/outlet chilled water temperature 7℃/12℃. 10 100A4 120A5 140A5 100.2 112.1 134.5 3 3 21600 21600 18 18 8 8 2490*890*1960 550 575 600 642 3 3 28900 28900 18 18 8 8 3095*890*2050 660 690 730 785 OPTIMA-FC/OPTIMA-FC-INV OPTIMA-FC precision air conditioner integrated with free cooling for critical application,including standard series of OPTIMA-FC and DC inverter series of OPTIMA-FC-INV, is applicable to large and medium-sized data center and electronic equipment room. It has a wide range cooling capacity, high operating reliability and stability. Equipped with EC fan, precise control of temperature±1℃, relative humidity ±5% which can assure the reliable and stable environment of the data room.For double cooling source version, the unit can provide cooling by either chilled water or direct expansion cooling, providing higher reliability and flexibility for efficient operation. Free Cooling version can greatly reduce the energy consumption and cut the energy bill. OPTIMA-FC/OPTIMA-FC-INV has two direct expansion cooling type, aircooled and water-cooled. There are two schemes of supply air--up supply and down supply can be provide to different needs of equipment room. Easily maintain from the front of the product. OPTIMA-FC/OPTIMA-FC-INV has three working mode:mechanical cooling, partial free cooling and free cooling only. OPTIMA-FC/OPTIMA-FC-INV series double cooling source version has three working mode, mechanical cooling, chilled water cooling and double cooling source. Direct expansion air-cooled (DXA) work with CME or AMAE condenser. Direct expansion water-cooled (DXW) work with CMEH dry cooler or central cooling tower and pumping group. Chilled water coil work with chiller plant, central cooling tower or CMEH dry cooler and pumping group. OPTIMA-FC.DXA/DXW Model Supply air scheme Power source Cooling capacity DXA(1) DXW(2) Free cooling capacity(3) DXA DXW Compressor Supply fan Type Qty. of fan Air volume Electric heater capacity Humidification capacity Air cooled condenser(DXA) Dry cooler(DXA) Dry cooler(DXW) Width*Depth*Height DXA Weight DXW Weight 16E1A1 20E1A1 26E1A2 30E1A2 35E1A2 40E2A3 50E2A3 60E2A4 70E2A4 80E2A4 90E2A5 100E2A5 O:Up flow; U:Down flow 380V-3Ph-50Hz kW kW 18.9 17.6 22 21.5 28.5 27.9 31.9 31.2 37.6 36.1 46.6 45.8 kW kW 16.5 16.5 21.8 21.8 30.1 30.1 33.6 33.6 37.6 37.6 n. m3/h kW Kg/h 1 5750 6 3 1 6320 6 3 1 8900 9 5 1 9600 9 5 1 9600 9 5 Model*n. CME5*1 CME8*1 CME10*1 CME10* CME15*1 55.1 57.2 65.3 62.1 74.5 72.2 84.6 82.3 90.7 90.4 103.4 106.7 42.4 50.3 55.9 42.4 50.3 55.9 Hermetic Scroll Type 67.3 67.3 78.5 78.5 93.4 93.4 104.6 104.6 3 19200 18 8 3 21000 18 8 3 24600 18 8 3 27900 18 8 CME10*2 CME10*2 CME15*2 CME15*2 CME20*2 CME20*2 EC Centrifugal Fan 2 2 3 12600 13600 17800 13.5 13.5 18 8 8 8 CME8*2 Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH40*1 CMEH50*1 CMEH50*1 CMEH60*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH60*2 Model*n. CMEH20*1 CMEH30*1 CMEH40*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2 mm Kg Kg 875*890*1960 315 366 348 405 1480*890*1960 375 413 420 423 464 476 1750*890*1960 630 680 708 770 2490*890*1960 940 980 1040 1037 1085 1157 3095*890*2050 1230 1270 1338 1392 (1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃; (2) Return air dry bulb temperature 24℃,RH50%,inlet chilling water temperature 30℃, standard chilling water flow under standard condition; (3) Return air dry bulb temperature 24℃,RH50%,Outdoor temperature 2℃, standard chilling water flow under standard condition. 11 OPTIMA-FC-INV.DXA/DXW Model Supply air scheme Power source Cooling capacity DXA(1) DXW(2) Free cooling capacity(3) DXA(3) DXW(3) Compressor Supply fan Type Qty. of fan Air volume Electric heater capacity Humidification capacity Air cooled condenser(DXA) Dry cooler(DXA) Dry cooler(DXW) Width*Depth*Height DXA Weight DXW Weight 16E1A1 22E1A2 30E1A2 35E2A3 45E2A3 55E2A3 60E2A4 70E2A4 80E2A4 90E2A5 110E2A5 O:Up flow; U:Down flow 380V-3Ph-50Hz kW kW 16.1 17.2 22.2 23.5 30.1 32.1 35.5 36.8 70.3 73.5 80.1 82.3 91.5 93.7 111.9 115.4 kW kW 17.1 17.1 23.5 23.5 34.5 34.5 37.8 41.7 57.1 63.6 75.3 37.8 41.7 57.1 63.6 75.3 Hermetic DC Inverter Scroll Type 84.4 84.4 93.4 93.4 114.6 114.6 n. m3/h kW Kg/h Model*n. Model*n. Model*n. mm Kg Kg 1 5750 6 3 1 8900 9 5 1 9600 9 5 3 21000 18 8 3 24600 18 8 3 27900 18 8 AMAE6*1 2 12600 13.5 8 AMAE8*1 AMAE10*1 AMAE6*2 46.7 48.1 55.2 56.4 61.2 63.5 EC Centrifugal Fan 2 2 3 12600 13600 17800 13.5 13.5 18 8 8 8 AMAE8*2 3 19200 18 8 AMAE8*2 AMAE10*2 AMAE12*2 AMAE15*2 AMAE18*2 AMAE20*2 CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2 CMEH20*1 CMEH30*1 CMEH40*1 CMEH50*1 CMEH60*1 CMEH70*1 CMEH80*1 CMEH50*2 CMEH50*2 CMEH60*2 CMEH70*2 875*890*1960 375 405 1480*890*1960 490 520 510 540 1750*890*1960 750 790 790 830 2490*890*1960 830 875 1080 1120 1130 1160 3095*890*2050 1220 1280 1420 1470 1510 1590 (1) Return air dry bulb temperature 24℃,RH50%,outdoor dry bulb temperature35℃, variable speed compressor is operating at economic speed; (2) Return air dry bulb temperature 24℃,RH50%,inlet chilling water temperature 30℃, chilling water flow under standard condition, variable speed compressor is operating at economic speed; (3) Return air dry bulb temperature 24℃,RH50%,outdoor temperature 2℃, chilling water flow under standard condition. 12 OPTIMA-HD OPTIMA-HD is one type of precision air conditioners with high density cooling capacity by using chilled water, applicable to large and mediumsized data center and electronic equipment room. It has a wide range cooling capacity, high operating reliability and stability, the density of cooling capacity is up to 75kW/m2 which can save a lot of space in equipment room. Equipped with EC fan, OPTIMA-HD has a high operating efficiency, precise control of temperature +/- 1℃, relative humidity +/-5% which can assure the reliable and stable environment of the data room. There are three air flow schemes, up flow, down flow and front flow under rise floor can be provide to different needs of equipment room. Easily maintain from the front of the product. OPTIMA-HD use chilled water as cooling resource for mechanical cooling or free cooling. The system has the characteristics of simple structure, reliable and save the operating expense . OPTIMA-HD has two types: single circuit and dual circuits. Each circuit of dual circuits can be redundancy each other or work simultaneously or rotation between mechanical cooling and chilled water of free cooling. Model Circuit Supply air scheme Power source Cooling capacity(1) Water flow(1) Water pressure drop(1) Supply fan Type Qty. of fan Air volume Electric heater capacity Humidification capacity kW m3/h kPa 40B1 60B1 42.1 7.2 95 60.7 9.6 97 80B2 100B2 120B3 140B3 160B4 180B4 50D1 60D1 80D2 100D2 120D3 140D3 CW: single circuit CWD: double circuit O:Up flow; U:Down flow U:Down flow 380V-3Ph-50Hz 380V-3Ph-50Hz 83.6 101.6 123.3 145.2 160.5 180.9 50.4 61.1 81.0 100.7 120.5 143.2 14.2 17.3 19.5 24.7 26.3 28.4 7.7 9.6 12.7 14.8 17.9 22.0 86 94 93.6 91.2 98.6 83.9 101.1 123.1 83.1 83.2 184.6 156.6 EC Centrifugal Fan EC Centrifugal Fan n. 1 1 2 2 3 3 3 3 1 1 2 2 3 3 m3/h 11700 12600 22600 23600 31800 32600 37200 37200 11600 12300 23600 22800 31200 33600 kW 9 9 13.5 13.5 18 18 18 18 9 9 13.5 13.5 13.5 13.5 Kg/h 8 8 8 8 8 8 8 8 8 8 8 8 8 8 1250*900*1900 1750*900*1900 2560*900*1900 Width*Depth*Height(O/U)(2) mm 900*900*1960/1730 1750*900*1960/1730 2490*900*1960/1730 2905*900*1960/1730 Weight Kg 375 405 525 560 670 750 840 910 380 405 465 490 580 640 (1) Return air dry bulb temperature 24℃,RH50%,inlet/outlet chilled water temperature 7℃/12℃; (2) Excluding the height of return air plenum of up flow unit and supply air plenum of down flow unit. 13 DATACOOL DATACOOL Precision air conditioning units are widely applied in small/medium data center and computer rooms. DADATCOOL unit adopts new technologies, using efficient compressor and fans and optimizing refrigerating system configuration, to achieve its high efficiency and reliability, realizing COP >2.9, temperature control accuracy <±1℃ while humidity control accuracy <±5%. The compact structure and light weight makes easy installation. The unit can be fully maintained from the front, greatly reducing the maintenance cost. DATACOOL unit is available in 4 different air flow scheme: front up flow, down flow, displacement flow, top flow, offering more options for different customers. Model Supply air scheme Power source Cooling capacity(1) Compressor Supply fan Qty. of fan Air volume Electric heater capacity Humidification capacity Air cooled condenser Width*Depth*Height Weight 5E1C0 7E1C0 13E1C0 7E1C1 10E1C1 13E1C1 15E1C2 18E1C2 22E1C3 25E1C3 30E1C3 O: up-front throw O: up-front throw; U: Bottom Throw; DL: Replacement; TP: top throw 380V-3Ph-50Hz 5.8 7.4 13.2 7.6 10.7 13.6 15.4 18.3 22.2 25.4 30.2 Rotor Hermetic Scroll n. m3/h kW Kg/h 1 1650 2.3 3 1 1650 2.3 3 1 2630 4.5 3 1 2450 2.3 3 1 2450 4.5 3 1 2950 4.5 3 1 3450 6 5 1 3450 6 5 2 5100 9 5 CMD3*1 CMD4*1 CMD5*1 CMD4*1 CMD4*1 CMD5*1 CME5*1 CME8*1 CME8*1 mm Kg 650*580*1910 120 135 155 650*650*1910 142 165 180 900*750*1910 255 290 2 6500 9 8 2 6500 9 8 CME10*1 CME10*1 1300*750*1910 370 460 490 (1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃. DATACOOL-PACKAGE DATACOOL-PACKAGE air conditioner with built-in fresh air free cooling system is specially designed for small/medium data center and electronic equipment room. Due to its proper working logic and standard EC supply fan, DATACOOLPACKAGE can maximum works in free cooling mode with the lowest power consumption, saving huge energy and lowering the operation cost. DATACOOL-PACKAGE is a self-contained air conditioning unit which realizes easy installation without any refrigeration piping connection. The unit can be fully maintained from the front, greatly reducing the maintenance cost as well. DATACOOL-PACKAG is available in 2 different air flow schemes: up flow and down flow, offering more options for different customers to increase its application flexibility. Model Supply air scheme Power source Cooling capacity(1) Free cooling capacity(2) Compressor Evaporator fan Type Qty. of fan Air volume Condenser fan Type Qty. of fan Air volume Electric heater capacity Width*Depth*Height(packaged unit) Width*Depth*Height(split unit) Weight (packaged unit) Weight (split unit) 14 8E1A1 kW kW 9.1 13.1 n. m3/h 1 4350 n. m3/h kW mm Kg Kg 15E1A1 22E1A2 O:Up flow; U:Down flow 380V-3Ph-50Hz 16.5 23.9 18.5 25 Hermetic Scroll Type EC Centrifugal Fan 1 1 6150 8320 30E2A2 45E2A3 33 27.5 48.6 50 1 9150 2 16640 EC Centrifugal Fan 1 1 1 2 4200 5100 5800 10200 4.5 4.5 4.5 6 1160*1050*2350 1460*1100*2350 1160*1050*2450 1460*1100*2450 450 520 610 660 500 570 680 730 (1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃; (2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃. 4 14400 9 2920*1100*2350 2920*1100*2450 1280 1420 MOBILECOOL-OUTDOOR MOBILECOOL-OUTDOOR is a package type telecommunication base station special air conditioner and designed for telecommunication base station, small electronic equipment room. The unit features including good structure, easy maintenance, high sensible ratio, high efficiency, and high reliability. The air supplied from the front lower portion of the unit, which conforms with the air flow rules well, making the heat exchange more efficiency. MOBILECOOL-OUTDOOR uses EC fan supplied with alternating current (direct current is optional). The unit is available in single or dual-control, supplying various running strategies. The free cooling function is standard configuration, saving the energy consumption highly. MOBILECOOL-OUTDOOR installed in the outside of the shelter. The installation type can save the space of shelters. Model Supply air scheme Power source Cooling capacity(1) Free cooling capacity(2) Compressor Evaporator fan Type Air volume Condenser fan Type Air volume Width*Depth*Height Weight 3R1C1 5E1C1 kW kW 3.5 3.4 Rotory 5 4.0 m3/h 1000 m3/h mm Kg 3400 1200 7E1C2 10E1C2 DL:Replacement 230V-1Ph-60Hz 8.1 10 7.1 8.2 Scroll 13E1C3 18E1C4 7E1C2 13.4 8.9 17.8 12.9 8.1 7.1 EC Centrifugal Fan 2120 2460 2650 3850 2120 10E1C2 13E1C3 DL:Replacement 230V-3Ph-60Hz 10 13.4 8.2 8.9 Scroll EC Centrifugal Fan 2460 2650 Axial 3400 620*620*1930 135 145 5000 17.8 12.9 3850 Axial 6300 930*700*2139 235 18E1C4 240 6300 8200 1080*700*2139 1280*700*2139 280 320 5000 6300 930*700*2139 235 240 6300 8200 1080*700*2139 1280*700*2139 280 320 Model 3R1C1 5E1C1 7E1C2 10E1C2 13E1C3 18E1C4 5E1C1 7E1C2 10E1C2 13E1C3 18E1C4 Supply air scheme DL:Replacement DL:Replacement Power source 220V-1Ph-50Hz 380V-3Ph-50Hz Cooling capacity(1) kW 3.5 5.2 7.5 10.8 13.4 17.5 5.2 7.5 10.8 13.4 17.9 Free cooling capacity(2) kW 3.4 4.0 7.1 8.2 8.9 12.9 4.0 7.1 8.2 8.9 12.9 Compressor Rotory Scroll Scroll Evaporator fan Type EC Centrifugal Fan EC Centrifugal Fan Air volume m3/h 1000 1200 2120 2460 2650 3850 1200 2120 2460 2650 3850 Condenser fan Type Axial Axial Air volume m3/h 3200 3200 4200 5800 5800 7500 3200 4200 5800 5800 7500 620*620*1930 930*700*2139 1080*700*2139 1280*700*2139 620*620*1930 930*700*2139 1080*700*2139 1280*700*2139 Width*Depth*Height mm Weight Kg 135 145 235 240 280 320 145 235 240 280 320 (1) Return air dry bulb temperature 27℃、RH50%,Outdoor dry bulb temperature35℃; (2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃. 15 MOBILECOOL-INDOOR MOBILECOOL-INDOOR is a package type telecommunication base station special air conditioner and designed for telecommunication base station, small electronic equipment room. The unit features including good structure, easy maintenance, high sensible ratio, high efficiency, and high reliability. The air supplied from the front lower portion of the unit, which conforms with the air flow rules well, making the heat exchange more efficiency. MOBILECOOL-INDOOR uses EC fan supplied with alternating current (direct current is optional). The unit is available in single or dual-control, supplying various running strategies. The free cooling function is standard configuration, saving the energy consumption highly. MOBILECOOL-INDOOR installed in the inside of the shelter. The installation type is anti-theft, protecting the air conditioner from bad environment. Model Supply air scheme Power source Cooling capacity(1) kW Free cooling kW capacity(2) Compressor Evaporator fan Type Air volume m3/h Condenser fan Type Air volume m3/h Width*Depth*Height mm Weight Kg Model Supply air scheme Power source Cooling capacity(1) Free cooling capacity(2) Compressor Evaporator fan Type Air volume Condenser fan Type Air volume Width*Depth*Height Weight 3R1D0 5E1D1 3.4 5 3.4 4.0 7E1D2 10E1D3 DL:Replacement 230V-1Ph-60Hz 7.9 9.8 7.1 Rotory 8.2 7E1D2 13.2 7.9 8.9 7.1 10E1D3 13E1D4 DL:Replacement 230V-3Ph-60Hz 9.8 13.2 8.2 Scroll EC Centrifugal Fan 2120 2460 1000 1200 2400 2800 Centrifugal Fan 2800 500*600*2000 600*600*2000 130 160 3R1D0 5E1D1 kW 3.4 5.2 kW 3.4 4.0 EC Centrifugal Fan 2460 2650 2650 2120 4200 5600 2800 Centrifugal Fan 4200 5600 750*650*2100 860*650*2100 1010*650*2100 750*650*2100 860*650*2100 1010*650*2100 200 255 290 200 255 290 7E1D2 10E1D3 DL:Replacement 220V-1Ph-50Hz 7.4 10.6 7.1 Rotory 8.2 13E1D4 5E1D1 13.3 5.2 8.9 4.0 7E1D2 10E1D3 DL:Replacement 380V-3Ph-50Hz 7.4 10.6 7.1 Scroll 8.2 1000 1200 EC Centrifugal Fan 2120 2460 2650 1200 EC Centrifugal Fan 2120 2460 m3/h mm Kg 2400 2800 Centrifugal Fan 2800 4200 5600 2800 Centrifugal Fan 2800 4200 500*600*2000 600*600*2000 750*650*2100 860*650*2100 1010*650*2100 600*600*2000 750*650*2100 860*650*2100 160 200 13E1D4 13.3 8.9 Scroll m3/h 130 8.9 Scroll 255 290 (1) Return air dry bulb temperature 27℃,RH50%,Outdoor dry bulb temperature35℃; (2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃. 16 13E1D4 160 200 255 2650 5600 1010*650*2100 290 MOBILECOOL-SPLIT MOBILECOOL-SPLIT is a spilt type telecommunication base station special air conditioner and designed for telecommunication base station, small electronic equipment room. The unit features including good structure, easy maintenance, high sensible ratio, high efficiency, and high reliability. The air supplied from the front lower portion of the unit, which conforms with the air flow rules well, making the heat exchange more efficiency. MOBILECOOL-SPLIT uses AC fan supplied with alternating current (direct current is optional). The unit is available in single or dual-control, supplying various running strategies. The free cooling function is optional, saving the energy consumption highly. Model Supply air scheme Power source Cooling capacity(1) Free cooling capacity(2) Compressor Supply fan Type Air volume Width*Depth*Height Weight Condenser unit Model Width*Depth*Height Weight 5R1D1 kW kW 7R1D1 220V-1Ph-50Hz 5.5 7.6 5.9 5.9 Hermetic Rotary Type 10E1D2 13E1D2 O:Up flow; DL: Replacement 380V-3Ph-50Hz 10.4 13.3 7.4 11.6 Hermetic Scroll Type 15E1D2 14.9 11.6 m3/h mm kg 1800 600*500*1700 70 AC Centrifugal Fan 1800 2250 600*500*1700 750*500*1700 80 150 3500 750*500*1700 160 750*500*1700 165 mm kg CMD3 808*509*789 29 CMD4 808*509*789 35 CMD5 1004*509*930 43 CMD6 1250*509*930 92 CMD4 808*509*789 35 3500 (1) Return air dry bulb temperature 27℃,RH50%,Outdoor dry bulb temperature35℃; (2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃(only for DL air supply scheme unit). 17 METROCOOL METROCOOL unit is specially designed for industry environment, standing up to high temperature, heavy pollution and continuous working demand and offering high efficiency, strict fire proofing, various power supplies and widely working condition with high reliability. METROCOOL is a split air conditioning unit with rational structure for convenient maintenance. Electrical heaters with different capacity are available for this unit as options to satisfy different application requirement. Model Power source Cooling capacity(1) Unit max. operating power input Unit max. operating current Indoor unit Fan type Air volume Width*Depth*Height Weight Outdoor unit Compressor Fan type Width*Depth*Height Weight Piping connection Condensing water drainage Refrigerant liquid Refrigerant gas MTC.5 kW kW A m3/h mm Kg MTC.7 MTC.10 MTC.13 MTC.5 MTC.7 MTC.10 MTC.13 MTC.5 MTC.7 MTC.10 MTC.13 380V-3Ph-50Hz 220V-1Ph-50Hz 208~230V-1Ph-60Hz 7.3 10.0 13.0 5.2 7.3 10.0 13.0 5.0 6.8 10.7 13.0 3.9 5.3 6.5 3.4 4.0 5.5 6.5 2.9 3.8 5.3 6.8 9.5 12.2 16.5 14.7 18.9 27.0 24.6 13.1 16.6 24.8 31.2 5.2 3.2 8.0 Double Inlet Centrifugal Fan 1400 1400 1600 2000 Double inlet Centrifugal Fan 1400 1400 1600 2000 Double inlet Centrifugal Fan 1400 1400 1600 2000 1295*280*680 1295*310*870 1295*280*680 1295*310*870 1295*280*680 1295*310*870 52 64 52 64 52 64 54 67 Hermetic scroll type Axial flow fan 54 67 Hermetic scroll type Axial flow fan 54 67 Hermetic scroll type Axial flow fan mm Kg 91 95 123 145 91 95 123 145 91 95 123 145 mm in in 16 3/8″ 1/2″ 16 1/2″ 5/8″ 16 1/2″ 3/4″ 16 1/2″ 3/4″ 16 1/2″ 5/8″ 16 1/2″ 5/8″ 16 1/2″ 3/4″ 16 1/2″ 3/4″ 16 1/2″ 5/8″ 16 1/2″ 5/8″ 16 1/2″ 3/4″ 16 1/2″ 3/4″ 1260*590*880 1440*590*1125 1305*590*1500 1260*590*880 1440*590*1125 1305*590*1500 1260*590*880 1440*590*1125 1305*590*1500 (1) Top grade air flow, return air dry bulb temperature 27℃,wet bulb temperature 19℃,outdoor dry bulb temperature35℃, wet bulb temperature 24℃. 18 TELECOOL Cabinet air condition is actively cooling with compressor, and it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet, avoiding problems from using fan. The inside cabinet can be maintained at an ideal temperature for electrical components which effectively guarantees the stability of the electronic equipment and improves the reliability of the whole system. The products can be widely used for outdoor communication cabinets, battery cabinets, electric cabinets, industry control cabinets etc. Model Cooling Capacity(L35/L35) Rated Power Working Voltage Working Temperature Refrigerant Noise Ambient Air Circuit Cabinet Air Circuit Width*Depth*Height(R134a) Width*Depth*Height(R22) TC.AC.300 TC.AC.400 TC.AC.600 TC.AC.800 TC.AC.1000 W W 300 220 400 240 600 365 800 460 dB m3/h m3/h mm mm 55 280 160 R134a 55 56 280 450 160 200 58 450 230 353*165*583 455*155*692 TC.AC.1200 TC.AC.1500 TC.AC.2000 TC.AC.2500 TC.AC.3000 1000 1200 1500 2000 490 610 685 830 220VAC±15% 50/60Hz -40~55℃ R134a/R22 60 62 64 68 540 580 780 950 250 360 450 560 482*187*781 497*188*897 460*188*1087 / 482*187*781 497*188*897 2500 1020 3000 1240 68 1150 640 70 1380 780 549*220*1208 569*220*1308 460*188*1087 549*220*1208 (1) Return air dry bulb temperature 35℃,outdoor dry bulb temperature35℃. Model Cooling Capacity(L35/L35) Rated Power Working Voltage Working Temperature Refrigerant Noise Ambient Air Circuit Cabinet Air Circuit Width*Depth*Height W W TC.DC.400 400~600 240 TC.DC1000 800~1000 450 TC.DC.2000 1500~2000 725 TC.DC.3000 2500~3000 1120 64 780 450 497*188*897 68 1380 780 549*220*1208 DC 48V -40~55℃ R134a dB m³/h m³/h mm 55 450 200 455*155*692 60 540 250 482*187*781 (1) Return air dry bulb temperature 35℃,outdoor dry bulb temperature35℃. 19 FREECOOL-HD FREECOOL-HD intelligent ventilation unit is applied in small/medium data center and electronic equipment room. The unit introduces outdoor fresh air with lower temperature to cool equipment room. By using the FREECOOL-HD unit, the running hours of other air conditioning units can be highly reduced, achieving power energy saving around 30~90%. The FREECOOL-HD unit using EC fans can adjust the air volume automatically according to the temperature difference with the lowest power consumption. FREECOOL-HD without refrigeration system realizes easy installation and convenient maintenance. The unit is available in 2 different air flow schemes: up flow and down flow, and 2 installation positions: outdoor and indoor, offering more options for different customers. Model Supply air scheme Air volume Air volume Cooling capacity △t=5℃ △t=10℃ △t=12℃ Power source Fan Type Qty. of fan Input power Current Width*Depth*Heigh Weight 20 m3/h m3/s kW kW kW n. kW A mm kg 24F1 48F2 2400 0.67 4750 1.3 4.0 7.9 8.0 15.8 9.6 19 230V/1/(50/60Hz) 1 0.5 3.1 700*450*1320 65 72F1 O/U 7200 2.0 144F2 216F3 14400 4.0 21600 6.0 12.0 24.0 28.8 24.0 48.0 57.6 400V/3/(50/60Hz) 36.0 72.0 86.4 Single inlet backward curved centrifugal fan 2 1 2 1.0 2.1 4.2 6.1 3.2 6.4 1150*450*1320 850*800*1770 1650*800*1770 89 150 260 3 6.3 9.4 2450*800*1770 350 FREECOOL FREECOOL intelligent ventilation unit is applied in shelters and small equipment room. The unit introduces outdoor fresh air with lower temperature to cool equipment room. By using the FREECOOL unit, the running hours of other air conditioning units can be highly reduced, achieving power energy saving around 30~90%.The FREECOOL DC series using EC fans can adjust the air volume automatically according to the temperature difference with the lowest power consumption. FREECOOL is able to control up to 2 air conditioners. The unit is available in various installation positions: outdoor and indoor, packaged and split, offering more options for different data centre. Model Structure type Cooling capacity △t=5℃ kW △t=10℃ kW △t=12℃ kW Power source Fan Type Qty. of fan n. Air volume m3/h Input power(48VDC) kW Input power(220VAC) kW Width*Depth*Height(ID) mm Width*Depth*Height(OD) mm Weight(ID) Kg Weight(OD) Kg 12F1 18F1 24F1 30F2 ID/OD Package 35F2 1.7 2.4 3.4 4.4 5 3.1 4.8 6.8 8.7 9.9 3.8 5.7 8.1 10.5 11.9 48VDC;220VAC (Only available for ID installation unit) Single inlet backward curved centrifugal fan 1 1 1 2 2 1000 1450 2050 2650 3000 0.06 0.19 0.22 0.3 0.4 0.13 0.18 0.39 0.36 0.5 650*500*1100 750*600*1400 650*500*1320 750*630*1620 60 60 65 85 85 65 65 68 115 115 12F1 18F1 24F1 ID/OD Split 30F1 35F1 1.7 2.9 3.4 5 5.7 3.3 5.8 6.8 10 11.4 4 6.9 8.1 12 13.7 48VDC;220VAC (Only available for ID installation unit) Single inlet backward curved centrifugal fan 1 1 1 1 1 1000 1750 2050 3030 3450 0.06 0.19 0.23 0.26 0.39 0.13 0.18 0.39 0.38 0.57 550*450*700 600*500*900 550*550*600 610*610*630 40 40 42 48 50 38 38 40 45 45 21 Outdoor condenser and dry cooler The covers of CME air-cooled condenser are produced by aluminum sheet, which has characteristics of light weight, Anti-corrosion, anti-rust, etc. The condenser is equipped with adjustable speed axial fan and high efficiency heater exchanger. Vertical or horizontal installation of the condenser is available. The covers of AMAE air-cooled condenser are produced by aluminum sheet, which has characteristics of light weight, anti-corrosion, anti-rust, etc. The condenser is equipped with EC axial fan which has characteristics of big air volume, lower power consumption and adjustable fan speed and high efficiency heater exchanger. The condenser is suitable for high temperature working conditions. Vertical or horizontal installation of the condenser is available. CMD air-cooled condenser is used for small precision air conditioner or base station air conditioner. The covers of CMD condenser are produced by coating sheet metal, which has characteristics of anti-corrosion, anti-rust, etc. The condenser is equipped with adjustable speed axial fan and high efficiency heater exchanger. Only vertical installation of the condenser is available. The covers of CMEH dry cooler are produced by aluminum sheet, which has characteristics of light weight, Anti-corrosion, anti-rust, etc. The condenser is equipped with adjustable speed axial fan and high efficiency heater exchanger. Vertical or horizontal installation of the condenser is available. CMD/CME Model Power source Capacity (1) Fan Qty. of fan Air volume Input power Input current Gas pipe Liquid pipe Width*Depth*Height Weight CMD3 CMD4 CMD5 CMD6 CME4 kW 9.3 13.7 20.4 23.6 15.6 n. m3/h kW A ODF ODF mm Kg 1 4400 0.28 1.3 5/8" 1/2" 1 4100 0.28 1.3 5/8" 1/2" 1 5600 0.37 1.7 5/8" 1/2" 1 5800 0.37 1.7 5/8" 1/2" 1 4400 0.28 1.3 16 12 808*509*789 29 35 CME5 CME8 220V-1Ph-50Hz 20.5 29.6 1 5600 0.37 1.7 19 12 1004*509*930 1250*509*930 840*475*770 1140*475*770 43 92 37 47 (1) Heat dissipating capacity @ inlet air temperature 35℃, condensation temperature 50℃. 22 1 10100 0.63 3 22 16 CME10 CME15 35.4 47.6 67.4 73.1 1 9700 0.63 3 22 16 2 11600 0.74 3.4 22 19 2 20100 1.26 6 28 19 2 19100 1.26 6 35 22 1340*620*1070 95 110 1540*620*1070 130 CME20 CME25 2400*630*1135 155 185 AMAE Model Power source Capacity (1) Fan Qty. of fan Air volume Input power Input current Gas pipe Liquid pipe Width*Depth*Height Weight AMAE5 AMAE6 AMAE8 kW 24.2 29.7 36.2 n. m3/h kW A ODF ODF mm Kg 1 12500 0.63 2.8 19 16 1 11600 0.63 2.8 19 16 1 11800 0.63 2.8 19 16 1365*620*1080 103 116 AMAE10 AMAE12 220V/1Ph/50Hz 41.3 50.7 1 11500 0.63 2.8 22 16 2 23500 1.26 5.6 22 16 1665*620*1080 135 AMAE15 AMAE18 AMAE20 57.2 62.4 74.3 2 22000 1.26 5.6 22 16 2 23400 1.26 5.6 22 19 2 22600 1.26 5.6 28 19 1985*620*1080 152 173 182 2790*620*1080 206 220 (1) Heat dissipating capacity @ inlet air temperature 35℃, condensation temperature 50℃. CMEH Model Power source Capacity Heat exchange coil Water flow Pressure drop Fan Qty. of fan Air volume Nominal mechanical power Max electric absorption Width*Depth*Height Weight CMEH20 CMEH30 kW 23.2 31.2 m3/h 3.5 71.1 5.2 68.2 kPa n. m3/h kW A mm Kg 1 1 12100 11200 0.75 0.75 3.3 3.3 1350*620*1070 95 115 CMEH40 CMEH50 220V/1Ph/50Hz 45.3 56.7 6.2 58.7 2 22800 1.5 6.6 1980*620*1120 145 9.3 57.6 CMEH60 CMEH70 CMEH80 61.5 75.2 83.1 10.2 69.1 10.6 72.3 11.8 78.5 2 2 23200 21800 1.5 1.5 6.6 6.6 2700*620*1120 175 195 3 3 33600 32400 2.3 2.3 10.1 10.1 3580*620*1120 235 255 (1) Heat dissipating capacity @ inlet air temperature 35℃, inlet water temperature 45℃. 23 CRITICOOL/CRITICOOL-FC CRITICOOL series is applicable to large-sized data center and all kinds of industrial technology place. It has a wide range cooling capacity, high operating reliability and stability. CRITICOOL-FC is equipped with additional chilled water coil, free cooling system will be used when outdoor temperature is low enough, minimize the run time of mechanical cooling and save huge energy and lowering the operation cost. CRITICOOL adopts screw compressor, offer built-in pump group as option, the customer only need to connect water pipe and power supply cable on the site. Outdoor installation, no room occupied. Standard Model Cooling capacity(1) Heating capacity(2) Qty of compressor Heating capacity of partial heat recycle(Option)(3) Length Width Height Weight (4) (1) (2) (3) (4) kW kW n. 130V1 115 128.8 1 150V1 138 154.6 1 200V1 178 199.4 1 250V1 245 274.4 1 350V1 315 356 1 400V1 377 422.2 1 450V1 408 457 1 500V1 475 532 1 400V2 370 414.4 2 450V2 420 470.4 2 700V2 630 711.9 2 800V2 754 844.5 2 kW 34 41 56.8 80.5 103.7 120.3 122.4 142.5 118 126 198 216.7 mm mm mm kg 3600 1290 2280 1640 3600 1290 2280 1780 4335 1290 2280 1910 5170 1290 2280 2350 4980 2130 2540 3425 4980 2130 2540 3800 4980 2130 2540 3880 6490 2130 2540 4850 4980 2130 2540 3960 6490 2130 2540 4900 7480 2130 2540 6250 8470 2130 2540 7000 Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃; Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃; The inlet temperature of heat recycle 40℃; Exclude the weight of option. Compact type Model Cooling capacity(1) Heating capacity(2) Qty of compressor Heating capacity of partial heat recycle(Option)(3) Length Width Height Weight (4) (1) (2) (3) (4) 24 kW kW n. 700V2 750V2 800V2 890V2 950V2 1000V2 1100V2 1200V2 900V3 1000V4 1200V4 1400V4 1500V4 1600V4 630 692 754 816 883 942 1033 1124 880 996 1126 1256 1390 1508 712 778 844 914 991 1066 986 1118 1261 1407 1557 1689 2 2 2 2 2 2 2 2 3 4 4 4 4 4 kW 189 207.6 226.2 244.8 264.9 282.6 309.9 337.2 264 320.4 396 396 448 481.2 mm mm mm kg 6450 2350 2600 6760 6750 2350 2600 7080 7050 2350 2600 7400 7050 2350 2600 7650 8130 2350 2600 8190 9210 2350 2600 9260 10290 2350 2600 10280 11370 2350 2600 11300 8710 2350 2600 9520 10780 2350 2600 11920 11340 2350 2600 12740 12900 2350 2600 13520 13500 2350 2600 14160 14100 2350 2600 14800 Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃; Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃; The inlet temperature of heat recycle 40℃; Exclude the weight of option. Standard free cooling type Model Cooling capacity(1) Cooling capacity(2) Free cooling capacity(3) Qty. of compressors Length Width Height Weight Model Cooling capacity(1) Cooling capacity(2) Free cooling capacity(3) Qty. of compressors Length Width Height Weight (1) (2) (3) (4) kW kW kW n. mm mm mm kg kW kW kW n. mm mm mm kg 350V1 312 346 348 1 3410 2350 2600 3780 800V2 746 829 833 2 7050 2350 2600 8350 400V1 373 414 416 1 3710 2350 2600 4140 890V2 808 897 901 2 7050 2350 2600 8590 450V1 404 448 451 1 3710 2350 2600 4305 950V2 874 970 975 2 8130 2350 2600 9270 500V1 470 522 525 1 4790 2350 2600 5130 1000V2 931 1034 1039 2 9210 2350 2600 11320 600V1 557 619 622 1 5870 2350 2600 6240 1200V2 1115 1237 1244 2 10290 2350 2600 13300 700V2 624 692 696 2 6450 2350 2600 7560 1400V2 1271 1411 1418 2 11370 2350 2600 14100 750V2 685 760 764 2 6750 2350 2600 7880 1600V2 1493 1657 1665 2 14100 2350 2600 16000 Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃; Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃; The inlet temperature of heat recycle 40℃; Exclude the weight of option. Low noise free cooling type Model Cooling capacity(1) Cooling capacity(2) Free cooling capacity(3) Qty. of compressors Length Width Height Weight kW kW kW n. mm mm mm kg Model Cooling capacity(1) Cooling capacity(2) Free cooling capacity(3) Qty. of compressors Length Width Height Weight kW kW kW n. mm mm mm kg (1) (2) (3) (4) 130V1 114 126 127 1 3600 1420 2280 1840 400V2 366 407 409 2 4980 2370 2540 4760 150V1 137 152 152 1 3600 1420 2280 1980 450V2 416 462 464 2 6490 2370 2540 5900 200V1 176 196 197 1 4355 1420 2280 2210 500V2 497 552 554 2 6490 2370 2540 6160 250V1 243 269 271 1 5170 1420 2280 2550 600V2 557 619 622 2 7480 2370 2540 7260 350V1 312 346 348 1 4980 2370 2540 3725 700V2 624 692 696 2 7480 2370 2540 7550 400V1 373 414 416 1 4980 2370 2540 4250 450V1 404 448 451 1 4980 2370 2540 5400 800V2 746 829 833 2 8470 2370 2540 8500 500V1 470 522 525 1 6490 2370 2540 5660 1000V2 941 1044 1049 2 13780 2370 2540 11320 600V1 557 619 622 1 7480 2370 2540 6650 1200V2 1115 1237 1244 2 15760 2370 2540 13300 700V1 636 705 709 1 7480 2370 2540 7050 1400V2 1271 1411 1418 2 15760 2370 2540 14100 800V1 746 829 833 1 8470 2370 2540 8000 1600V2 1493 1657 1665 2 18440 2370 2540 16000 Nominal cooling capacity @ outside DB is 35℃, chilled water outlet temperature 7℃, inlet temperature 12℃; Nominal heating capacity @ outside DB is 7℃, WB is 6℃; hot water outlet tempreature 45℃, inlet tempreature 40℃; The inlet temperature of heat recycle 40℃; Exclude the weight of option. 25 HYDROCOOL HYDRCOOL/HYDROCOO-HE series is applicable to large-sized data center and all kinds of industrial technology place. It has a wide range cooling capacity, high operating reliability and stability. HYDROCOO-HE is equipped with flooded evaporator, to achieve higher EER, save huge energy and lowering the operation cost. This series adopts screw compressor and flooded evaporator, minimized the unit size and footprint. Standard Model Cooling capacity (1) Cooling capacity (2) Heating capacity (3) Qty of compressor Heating capacity of partial heat recycle Length Width Height Weight (4) Model Cooling capacity (1) Cooling capacity (2) Heating capacity (3) Qty of compressor Heating capacity of partial heat recycle Length Width Height Weight (4) 250V1 229.5 238.2 237.5 1 kW kW kW n. 400V1 406.7 422.2 421.6 1 500V1 495.1 513.9 511.3 1 600V1 589.7 612.1 611 1 700V1 736.5 764.5 763 1 500V2 459 476.4 475 2 800V2 804.6 835.2 835.8 2 900V2 1000V2 1100V2 894.7 989.8 1076 928.7 1027.4 1116.9 927.1 1021.6 1115.5 2 2 2 1200V2 1300V2 1175.6 1320 1220.3 1370.2 1218.7 1369.1 2 2 kw 52.9 86.1 104.1 134.1 160 103.9 172.5 192.1 209.4 227.6 248.7 279.3 mm mm mm kg 3385 970 2000 1380 3385 970 2000 2000 3385 1060 2000 2320 3415 1060 2000 3110 3475 1060 2000 3280 3900 1160 1940 2400 4100 1160 2100 3610 4160 1160 2100 3740 4160 1160 2100 3820 4160 1300 2160 4100 4160 1540 2160 4600 4450 1540 2214 4750 kW kW kW n. 1400V2 1470.5 1526.4 1523.1 2 1600V2 1612.3 1673.6 1669.8 2 1800V2 1820.6 1889.8 1888.1 2 1600V4 1609.2 1670.3 1671.5 4 1800V4 1789.4 1857.4 1854.1 4 3200V4 3224.6 3347.1 3339.6 4 3600V4 3641.2 3779.6 3776.1 4 kW 311 338.6 382.3 345 381.7 418.9 455.2 535.6 582.9 635.1 677.2 764.6 mm mm mm kg 4510 1540 2214 4900 4510 1540 2214 5300 4510 1540 2214 5500 4100 2560 2100 7220 4160 2560 2100 7480 4160 2560 2100 7640 4160 2840 2160 8100 4160 3320 2160 9000 4450 3320 2214 9305 4510 3320 2214 9600 4510 3320 2214 10600 4510 3320 2214 11000 2000V4 2200V4 2400V4 2600V4 2800V4 1979.6 2125 2357.9 2644.5 2938 2054.8 2233.8 2447.5 2745 3049.6 2043.1 2231 2442.7 2740.3 3043.7 4 4 4 4 4 Full liquid Type Model Cooling capacity (1) Cooling capacity (2) Heating capacity (3) Qty of compressor Heating capacity of partial heat recycle Length Width Height Weight (4) Model Cooling capacity (1) Cooling capacity (2) Heating capacity (3) Qty of compressor Heating capacity of partial heat recycle Length Width Height Weight (4) 300V1 340V1 400V1 kW 274.3 321.8 379.3 kW 289.6 339.6 400.3 kW 296.2 348.1 409.9 n. 1 1 1 450V1 443.3 468.4 475.7 1 500V1 550V1 600V1 650V1 700V1 800V1 600V2 700V2 502.1 556 581.9 656 720 757.8 548.5 643.5 530.4 587.6 614.7 692.9 761.4 801.4 579.1 679.3 537.7 596.6 624.3 702 755 793.5 592.4 696.3 1 1 1 1 1 1 2 2 kw 68.6 80.4 94.8 110.8 125.5 139 145.5 164 180 189.5 137.1 160.9 189.7 221.7 251.1 mm mm mm kg 3555 1160 1630 2350 3555 1160 1630 2500 3555 1160 1630 2780 3570 1240 1880 3060 3970 1240 1880 3435 3985 1280 1880 3740 3985 1320 2070 3940 3995 1380 2070 4060 3995 1380 2070 4210 4470 1440 1990 6260 kw kw kw n. 1100V2 1111.9 1175.1 1193.1 2 kw 278 290.9 328 360 378.9 443.3 502.1 556 581.9 656 720 757.8 mm mm mm kg 4485 1540 2040 6950 4485 1540 2040 7410 4485 1590 2180 7810 4495 1640 2230 8020 4495 1640 2230 8350 4470 2950 2480 11900 4470 2950 2540 12520 4485 2950 2640 13900 4485 2950 2710 14820 4495 2950 2760 15620 4495 2950 2780 16040 4495 2950 2780 16700 3770 1240 1880 3200 4445 1240 1670 4435 4445 1240 1670 4720 800V2 758.6 800.6 819.7 2 4460 1320 1720 5530 900V2 886.7 936.9 951.5 2 4460 1380 1930 5950 1000V2 1004.3 1060.7 1075.4 2 1200V2 1300V2 1400V2 1600V2 1800V2 2000V4 2200V4 2400V4 2600V4 2800V4 2000V4 1163.7 1312 1440 1515.6 1773.3 2008.5 2223.8 2327.5 2624 2880 3031.2 1229.3 1385.8 1522.8 1602.8 1873.7 2121.5 2350.2 2458.7 2771.6 3045.6 3205.6 1248.7 1404.1 1510 1587 1902.9 2150.8 2386.2 2497.3 2808.1 3020 3174 2 2 2 2 4 4 4 4 4 4 4 (1) Cooling capacity @ evaporator water inlet and outlet temperature 12/7℃, condenser water inlet and outlet temperature 30/35℃; (2) Water source heating pump cooling capacity @ evaporator water inlet and outlet temperature 12/7℃, condenser water inlet and outlet temperature 15/30℃; (3) Water source heating pump heating capacity @ evaporator water inlet and outlet temperature 15/6℃, condenser water inlet and outlet temperature 40/45℃; 26 (4) Exclude the weight of option. Control system All AIRSYS products are equipped with AIRSYS advanced By running status and time records, you can keep microcomputer control system. Hardware meets industrial / abreast of the operational status of the unit, part of the ICT environment requirements, high reliability, anti-jamming. on / off status, running time and other information. Control program embodies AIRSY many years’ experience in ICT environment-air conditioner produce, fully consider reliable, energy saving, convenient needs, are the core values embodied AIRSYS products. Alarm and security alarm information and provide numerous security protection, including restart, current and voltage, phase sequence protection, pressure protection, thermal protection, and so on. By micro-controller, a large number of parameters can be set flexibly, including automatic / manual, operating logic selection, parameter calibration, the ON / OFF the designated member. There are several ways to achieve remote monitoring, remote setting parameters, upload programs, remote on / off, remote alarm, etc. Remote Control And Monitoring Network The unit can be remote controlled or monitored by many kinds of methods as follows: 3 kinds of local direct cable connection 3 kinds of LAN network connection 4 kinds of wireless network connection Local area network connection type Wireless connection types Cooling unit & Comm. card LAN connection 1 wireless communication network Wireless connection 1 N1 RS485 card MODBUS protocol 345$1*1wireless router RS485-TCP/IP converter with 16 ports Ethernet network cable RS485 Bus N2 Wireless connection 2 Wireless router Mobile phone Wireless connection 3 The computer is installed with TCP/IP cardˈRS485 cardˈ RS232 card and IntelliVision plus software GSM Mobile communication network N16 GSM module N1 LAN connection 2 Wireless connection 4 Mobile phone GSM module &UIFSOFUOFUXPSLDBCMF RS485 Bus N2 Monitoring Computer GSM communication network N16 Single unit direct connection types Direct connection 1 34%BUBDBCMF Units direct connection type N1 RS485-RS232 Converter Direct connection 2 34%BUBDBCMF RS485-RS232 Converter RS232 cable Direct connection 3 RS485 Bus N2 34%BUBMJOF Single port RS485-TCP/IP converter Direct connection 4 &UIFSOFUOFUXPSLDBCMF N16 27 Airsys Refrigeration Engineering Technology (Beijing) Co., Ltd. 28, Lu Gu Dong Jie, ShijingshanBeijing, China,100040 Tel:+86-10-6865 6161 Fax:+86-10-6865 2453 Gu'an Airsys Enviroment Technology Company Ltd. P.25, St. West Orient, Gu'an Industry Park, Gu'an County, Langfang City, Hebei Province, China. Tel:+86-10-6865 6161 Fax:+86-10-6865 2453 Shanghai Airserve HVAC Systerm Service Co., Ltd. #7-2,No.658,Daduhe Rd.,Putuo District,Shanghai,China,200333 Tel: +86-21-6245 2626 Fax:+86-21-6245 9622 Airsys Group (HK) Co., Ltd. Room 1305, Carnival Commercial Building, No. 18 Java Road, North Point,Hong Kong Tel: 00852-2711 0511 Fax: 00852-2711 1511 Airsys (UK) Ltd. Oak House Overbrook Lane Knowsley Business Park Liverpool,UK L34 9FB Tel: +44-845 2411007 Fax: +44-151 547 8801 www.air-sys.com Callcenter:+86-400-820-5515