Information regarding Deviation/ Variations approved by ERC of AIIMS, Bhubaneswar Sl. No 1 (A) 1 2 3 (B) Item 2 Variations Approved by ERC (In Rs) 4 ERC - 1, Dated-15-06-2013 Providing and fixing of vetrified tile in place Kota stone which is in BOQ item no-7.5 of Pkg-II. Extra Item- for providing and fixing pre coated galvanised iron profile sheets (Size, shape and pitch of corrugation as 5% total coated thickness (TCT), Zink coating 120 Gram as per IS :277 approved by EIC ) Extra Item - providing and fixing pre coated galvanised steel sheets roofing accessories etc complete for Ridges plain (500-600mm) 50361000.00 112814.00 12630.80 ERC - 2, Dated-18-06-2013 1 2.1 (b)--CC--1:3:6 2 12.2 SS Railing- Mechined component based moble or equal approve modular ss railing in stair etc having side mount balustar of 38mm dia X 2mm thick etc all complete. 3 Door window fixtures (EC) 1245637.62 (i) Providing locks for sliding windows (ii) Providing SS (304) friction stay for ventilator (iii) Providing single point locking handle for ventilator (iv) Aluminium door pad lock for aluminium door (C) ERC - 3, Dated-19-06-2013 1 2.1 (d) CC--1:5:10 2 2.2 (d) (El)--Supply, installation testing and commissioning of End Feed Unit to rising mains comprising of 4P MCCBs 35 KA in sheet steel enclosures with door interlocked. Rising main's bus bars will be connected to breaker terminals by solid copper connections provided to ensure expansion of bus bars upward only--300Amps. 426028.25 39535.84 3 4 5 6 7 (D) 2.2 (f) (El)--Supply, installation, testing and commissioning of End Free Unit to rising mains comprising of 4P MCCBs 35 KA in Sheet steel enclosures with door interlocked. Rising main's bus bars will be connected to breaker terminals by solid copper connections provided to ensure expansion of bus bars upward only-200 Amps 4680.00 3.23.2 Ceiling fan (El)--Supply, installation, testing & commissioning of the fan fixtures duly wired complete for use on 240 V single phase 50 Hz AC supply including all regulators, fan hooks, down rod and other fixing accessories as required.(Crompton Greaves model WW NEW or Bajaj model PRIDE ) 220591.61 4.1 (a) (El)---Supply, installation testing and commissioning of following way SPN /TPN prewired, sheet steel, MCB distribution board, 240V, on surface/recess, complete with loose wire box, terminal blocks(incomer terminal block and outgoing terminal blocks, phase, neutral and earth) , duly prewired with suitable size FRLS PVC insulated copper conductor cable up to terminal blocks, tinned copper bus bars, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing etc. as required complete with incoming and outgoing wire terminati:- a)SPN 2+8 way Double Door DB, with 32A DP MCB incomer & 8 nos. 10/16A SP MCB, 10 KA 4.1 (d) (El)-Supply, installation testing and commissioning of following way SPN /TPN prewired, sheet steel, MCB distribution board, 240V, on surface/recess, complete with loose wire box, terminal blocks(incomer terminal block and outgoing terminal blocks, phase, neutral and earth) , duly prewired with suitable size FRLS PVC insulated copper conductor cable up to terminal blocks, tinned copper bus bars, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing etc. as required complete with incoming and outgoing wire terminations with suitable thimbles and complete with incoming and outgoing switches a below:- d)TPN 4+18 way vertical type, Double Door DB, with 25/32A TPN MCB 10 KA & 18 nos. 10/16/20A SP MCB, 10 KA 126154.66 4.15 (f) (El)--Supply, installation testing and commissioning of following way SPN /TPN prewired, sheet steel, MCB distribution board, 240V, on surface/recess, complete with loose wire box, terminal blocks(incomer terminal block and outgoing terminal blocks, phase, neutral and earth) , duly prewired with suitable size FRLS PVC insulated copper conductor cable up to terminal blocks, tinned copper bus bars, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing etc. as required complete with incoming and outgoing wire terminations with suitable thimbles and complete with incoming and outgoing switches a below:f)TPN 4+36 way vertical type, Double Door DB, with 40/63A TPN MCB 10 KA & 36 nos. 10/16/20A 1172201.55 342586.86 ERC - 4, Dated-22-07-2013 Extra for core cutting for change in HVAC layout 98532.00 1 (E) 1 ERC - 5, Dated-27-08-2013 3.8 (2 x 28 recessed fitting)--2 x 28 W recess mounted low glare mirror optic luminaries (Philips Cat No Sereno TBS 869 /2 x TL5 28W D8 HF or Bajaj BTMRA 228 CAT II). 5.2 (b) End termination- Supply and making end termination with brass compression gland and aluminium / copper lugs for fallowing size of PVC insulated and PVC sheathed /XLPE Al. / copper conductor cable of 1.1 KV grade as required 251160.57 2 b) 3.5CX240Sqmm 6601.45 c) 3.5CX185Sqmm 8783.93 d) 3.5CX120Sqmm 5697.77 3 4 e) 3.5CX95Sqmm 1332.82 g) 3.5CX35Sqmm 22384.72 i) 4CX16Sqmm 28042.83 j) 4C x 10sqmm copper 14348.77 1.2 Circuit wiring 4x16 + 2x16 --Wiring for circuit / submain / AC / Gyser power sockets wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required. 2566228.33 5.4 Al/Cu Armoured conductor--Supply of following sizes 1.1 KV XLPE insulated, FRLS Al./Copper armoured Conductor, PVC inner sheathed, overall PVC sheathed cable in conformity to the technical specification and as per latest IS - codes. a) 3.5CX400Sqmm 426752.13 b) 3.5CX240Sqmm 55480.26 c) 3.5CX185Sqmm 348610.85 d) 3.5CX120Sqmm 319651.87 e) 3.5CX95Sqmm 6448.72 f) 3.5CX50Sqmm 94750.19 g) 4CX35Sqmm 215223.43 h) 4CX25Sqmm 217864.06 j) 4C x 10sqmm 1270502.06 1.3 (b) Plumbing wash basin--Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. 288758.52 5 6 1.4 Pedestal--Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. 107410.44 8 1.30 Urinal--Providing and fixing white glazed vitreous china urinal large (built in sensor) HSI.Cat. No. 60007 or approved equivalent Formal Statement to hangers with inbuilt electronic solenoid valve operated auto flushing system comprising solenoid valve, electronic control unit, etc., be issued complete with all electrical works required for completion of work, with fittings concealed in chase, C.P. spreaders, 32mm C.P. brass domical waste, 32mm C.P. brass trap, cast brass screws and washers complete including cutting and making good the walls and 1.51 Urinal partition--Providing and fixing white glazed vitreous china division plates for urinals (H.S.I. Cat no. 61.001 or approved Formal Statement to equivalent) of size 690x 325 mm. be issued 9 4.5 Extra Depth for manhole-- F ERC-6, Dated 11-09-2013 1 2x28W recess mounted low glare mirror mirror option luminaries (Philips Cat No Sereno TBS 869/2xTLS-28W D8 HF or Bajaj BTMRA 228 CAT-II). Item No-5.2 (b) : (Electric Work) Supply and making end termination with brass complression gland and aluminum/copper lugs for following size PVC insulated and PVC sheather aluminum/copper cable of 1.5 KV grade requirement. 7 2 99288.54 251160.57 b) 3.5CX240Sqmm 6601.45 c) 3.5CX185Sqmm 8783.93 d) 3.5CX120Sqmm 5697.77 e) 3.5CX95Sqmm 1332.82 g) 4CX35Sqmm 22384.72 i) 4CX16Sqmm 28042.83 j) 4C x 10sqmm (copper) 14348.77 3 4 x 16 sqmm + 2 x 16 sqmm earth wire 4 Item No 5.4. Supply of following sizes 1.1 KV LPE insulated, FRLS aluminum/copper armoured conductor, PVC inner sheath, pverall PVC sheathe cable in conforminity to the technical specification as per latest is codes. a) 3.5CX400Sqmtr 5 6 2566228.33 426752.13 b) 3.5CX240Sqmtr 55480.26 c) 3.5CX185Sqmtr 348610.85 d) 3.5CX120Sqmtr 319651.87 e) 3.5CX95Sqmtr 6448,72 f) 3.5CX50Sqmtr 94750.19 g) 4CX35Sqmtr 215223.43 h) 4CX25Sqmtr 217864.06 j) 4C x 10 sqmtr 1270502.06 Providing and fixing wash basin with C.I. brackers, 15mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including Formal Statement to painting of fittings and brackers, cutting and making good the walls wherever required. White vitreous chine surgeon type wash basin be issued of side 660 x 460mm). Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and Formal Statement to fittings. be issued 7 Providing and fixing white glazed vitreous chine urinal large (build in sensor) 8 Providing and fixing white glazed vitreous chine division plates for urinaLS OF SIZE 690 X 35 MM. 9 Extra for depth for manholes (Size 90 x 80 cm with F.P.S bricks class designation 75) G ERC-7, Dated 18-10-2013 Extra Item a) Conversation of central lawn to hard paved area Formal Statement to be issued Formal Statement to be issued Formal Statement to be issued b) Wooden frame second class teak wood as per BOQ item No 5.1A in place of Aluminium frame. c) Collapsible shutter at entrance of OT area and entrance of Trauma building of 22 SQMM 1,20,000.00 H ERC-8, Dated 19-11-2013 1 a) 1.2 (b)-4 x 10swmm + 2x10Sqmm earth wire Formal Statement to be issued b) 1.2 (e)-4x 6sqmm+2x6sqmm earth wire. Formal Statement to be issued 2 Providing and fixing 25mm x 5 mm G.I strip on surface or in racess for connections etc. as required. 3 Recessed down lighter with 2 x 18WPLC lamps with frosted glass. 4 Supplying and fixing 20 amps., 240 volts, SPN Industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps. 'C' series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required (including gyser, AC Point) 64829.3 5 a) Fabrication and installing 300mm width x 50mm depth x 1.6 mm thickness size perforated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other acessories as required and duly suspended from the ceiling with MS supenders and including painting with powder coating etc. as required. 311730.71 696561.8 b) Fabrication and installing 300mm width x 50mm depth x 1.6 mm thickness size perforated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other acessories as required and duly suspended from the ceiling with MS supenders and including painting with powder coating etc. as required. 6 7 8 Supply, installation, testing and commissioning of lighting discharge counter. The lighting event counters suitable for 1.0KA-100KA. Counter housed in weather proof IP67 enclosure with fixing clamps, etc. Supplying, drawing, connecting, testing & commissioning of shielded and stranded insulated (white sheathing with colour skinning) zero halogen copper conductor cable in existing conduit of the size 2C x 1.5 sqmm Supplying and fixing of following sizes of steel conduit alongwith the accessories in surface/recess including red ( fire)/yellow (telephone) factory painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as Extra items. 195832.11 6242983.74 9478098.5 1 All charges for supply, installation, testing & commissioning of 1 x 70W surface mounted down lighter. 249005.05 2 All charges for supply, installation, testing & commissioning of 1 x 10W surface mounted down lighter. 1278992.8 3 a) Supplying and fixing 32/20 amps, 240 volts, FP industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 32/20 amps. ‘C’ series, FP MCB, in sheet steel enclosure, on surface or in racess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required (including geyser, AC point, socket & KITCHEN) b) Supplying and fixing 63 amps., 240 volts, FP industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 63 amps. ‘C’ series, FP MCB, in sheet steel enclosure, on surface or in racess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required (including geyser, AC point, socket & KITCHEN). c) Supplying and fixing 32 amps., 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 32 amps. ‘C’ series, SPN MCB, in sheet steel enclosure, on surface or in racess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required (including geyser, AC point, socket & KITCHEN). 32198.88 TOTAL 85003428.84 39212.1 42852.36