TL106EX-CF - Barron Lighting Group

advertisement
TL106EX-CF
Compact Fluorescent Large Wallpack
DESCRIPTION
The Trace-lite TL106EX-CF Series is ideal for parking areas, entrances,
walkways, underpasses, loading docks, and recreation areas.
SPECIFICATIONS
Construction:
The Trace-lite TL106EX-CF Series features a durable, die-cast aluminum
enclosure with an architectural bronze powder coated finish. Enclosure
is fully sealed and gasketed, and is Wet Location Listed for outdoor
use. Enclosure and hardware are corrosion resistant. The TL106EX-CF
features an internal, anodized aluminum reflector which provides ideal light
distribution, and the lamp(s) are protected by a high-impact, heat resistant
borosilicate glass refractor.
Lamps & Ballasts
Compact Fluorescent: 4-Pin Triple Tube lamps from 26 to 42 watts in a single
or double lamp configuration, utilizing a GX24-q3 base with an electronic
programmed start ballast rated for a minimum operating temperature of
-20°C (-4°F).
Installation:
The Trace-lite TL106EX-CF Series is ideal for mounting to any vertical
surface and features a hinged design for easy access to internal components.
Unit can be wired to a 4’’ junction box or surface mounted using 1/2’’ NPS
conduit entry points.
ARRA - Buy America (Option: USA):
Fixture series may be built to comply with the American Recovery and
Reinvestment Act of 2009 (ARRA) requirements and Buy American provisions
- call factory for details.
Battery Back-up (Option: BB):
TRACE*LITE’s battery back-up option for compact fluorescent (CF)
luminaires provides up to 750 lumens for 90 minutes in the event of a primary
power failure. The emergency back-up option includes a battery pack along
with a charging/transfer device that keeps the battery pack charged during
normal AC operation and transfers battery power to the compact fluorescent
lamp when the device senses that the primary AC power has failed. Minimum
operating temperature for this option is 32°F (0°C).
Two (2) Ballast Option (Option: 2B):
On two (2) lamp CF fixtures, TRACE*LITE offers the option to use two
electronic compact fluorescent ballasts with one ballast powering one lamp
and the second ballast powering the second lamp. This option allows for two
circuit control of the luminaire in those applications where a redundant power
source, a generator set, or other methods of providing back-up or emergency
power is utilized.
Photocontrol (Accessory: PC):
Optional field-installed photocontrol provides dusk-till-dawn security. Input
voltage must be specified to match fixture input voltage.
Listing:
The TL106EX-CF is UL listed for wet locations.
Warranty:
Any housing component that fails due to manufacturer’s defect
is guaranteed for two years from time of shipment. Ballasts, Capacitors, and
Ignitors are warrantied for one year from time of shipment. Warranty does
not apply to damages caused by improper installation, abuse, fire or acts of
God. Lamp is not covered by manufacturer’s warranty.
Model:
Date:
Accessories:
Job Name:
Type:
SAMPLE PHOTOMETRICS
DIMENSIONS
TL106EX-CF-42 Mounted at 10’
50’
9.37 in.
18 in.
40’
.1fc
9.84 in.
30’
20’
.5fc
Approximate Weight: 16 lbs.
10’
1fc
0
10’
20’
30’
40’
0
ORDERING INFORMATION
Example: TL106EX-CF-42-120/277-BB
Series
Lamp Type
Lamp Wattage
Input Voltage
Options (Factory Installed)
TL106EX
CF = Compact Fluorescent
26 = 26 Watts
120/277 = 120/277VAC
BB1 = Battery Back-up
32 = 32 Watts
2B1 = Two AC Ballasts for (2) Lamp Fixtures
42 = 42 Watts
USA = Meets Buy America Requirements
52 = 2 x 26 Watts
64 = 2 x 32 Watts
Accessories2 (Field Installed)
84 = 2 x 42 Watts
PC1 = 120VAC Photocontrol
PC2 = 208-277VAC Photocontrol
WG106EX = Wire Guard
Notes
PG106EX = Polycarbonate Guard
1
This option is not UL Listed
FC106EX = Full Cutoff Shield
2
Order as separate line item
RL106EX = Replacement Lens
Specifications are subject to change without notice.
Installation must be performed in accordance with
Barron Lighting Group installation instructions.
10810170 05/16