Dry Type 600 Volts and Below Single Phase Class 7400 Single Phase – General Purpose Transformers Single Phase – Export Model Transformers General purpose standard transformers are intended for power, heating, lighting, and light-duty control applications. See page 12-4 or contact your nearest Square D/Schneider Electric sales office for voltages not listed below. These general-purpose transformers are designed to accommodate voltage systems worldwide. kVA Catalog Number q Price Full Capacity Taps Degree C Weightk Enclosure Temp. Rise (Pounds) ck Single Phase – 240 X 480 V Primary 120/240 V Secondary 60 Hz UL Listed through 167 kVA cUL Listed through 10 kVA .050 .100 .150 .250 .500 50SV1A 100SV1A 150SV1A 250SV1B 500SV1B .750 1 1.5 2 3 750SV1F 1S1F 1.5S1F 2S1F 3S1F $ 87. 102. 121. 129. 184. None None None None None 55 55 55 80 80 4.2 4.5 6.2 10.5 13.8 1A 2A 3A 4A 5A 219. 287. 345. 427. 545. None None None None None 115 115 115 115 115 15.5 21.2 30.1 39.1 60 6A 7A 8A 9A 10A Export model transformers 10 kVA and smaller, certified by TUV (file no. E9571881.01) to meet EN60-742, are CE marked in addition to being UL and cUL Listed. For CE marked transformers in other ratings, see pages 12-12 through 12-16 in this Digest. Or contact your nearest Square D/Schneider Electric sales office for CE marked transformers up to 300 kVA, single and three phase. See page 12-9 for optional Fingersafe terminal block cover kit. Single Phase – 190/200/208/220 X 380/400/416/440 5 7.5 10 15 15 25 5S1F 7S1F 10S1F 15S1F 15S1H 25S3H 741. 1042. 1291. 2586. 1731. 2253. None None None None None 6–2.5%2+4–a 115 115 115 115 150 150 115 135 165 225 200 245 13B 13B 13B 15B 17D 17D kVA 37.5 50 75 100 167 37S3H 50S3H 75S3H 100S3H 167S3H 3003. 3652. 4953. 6403. 9406. 6–2.5%2+4–a 6–2.5%2+4–a 6–2.5%2+4–a 6–2.5%2+4–a 6–2.5%2+4–a 150 150 150 150 150 325 350 450 640 975 18D 18D 21D 22D 24D 7.5 10 15 25 200 250 200S3H 250S3H 14814. 19448. 6–2.5%2+4–a 6–2.5%2+4–a 150 150 1220 1535 25D 25D Single Phase – 480 V Primary 120/240 V Secondary 60 Hz UL/cUL Listed through 25 kVA 3 5 7.5 10 15 15 25 3S40F 5S40F 7S40F 2–5%FCBN 2–5%FCBN 2–5%FCBN 115 115 115 60 115 135 10A 13B 13B 1291. 2069. 1731. 2646. 2–5%FCBN 2–5%FCBN 2–5%FCBN 2–5%FCBN 115 115 150 115 165 225 200 300 13B 15B 17D 15B Single Phase – 600 V Primary 120/240 V Secondary 60 Hz UL Listed through 167 kVA cUL Listed through 10 kVA .050 .100 .150 .250 .500 50SV51A 100SV51A 150SV51A 250SV51B 500SV51B .750 1 1.5 2 750SV51F 1S51F 1.5S51F 2S51F 3 5 7.5 $ Catalog Numberq 1t 2 3 5 1S67F 2S67F 3S67F 5S67F 7S67F 10S67F 15S67H 25S67H Price Full Capacity Taps Deg. C. Weight k Enclosure Temp. Rise (Pounds) ck $ 562. 817. 1090. 1216. None None None None 115 115 115 115 21.2 39.1 55.2 135 7A 9A 10A 13B 1578. 1907. 2995. 4138. None None None None 115 115 150 150 165 165 225 260 13B 13B 17D 17D LUGS: Furnished by customer t 0.750 kVA EN rating per EN 60-742 1-10 kVA CE marked per EN 60-742 Single Phase – Buck and Boost Transformers $ 545. 741. 1042. 10S40F 15S40F 15S40Hj 25S40F V Primary, 110/220 V Secondary 50/60 Hz UL Listed through 25 kVA CE marked/cUL Listed through 10 kVA 87. 102. 125. 138. 194. None None None None None 55 55 55 80 80 4.2 4.5 6.2 10.5 13.8 1A 2A 3A 4A 5A 231. 302. 361. 448. None None None None 115 115 115 115 15.5 21.2 30.1 39.1 6A 7A 8A 9A 3S4F 5S4F 7S4F 590. 798. 1118. 2–5%FCBN 2–5%FCBN 2–5%FCBN 115 115 115 60 115 135 10A 13B 13B 10 15 25 10S4F 15S5H 25S5H 1391. 1870. 2450. 2–5%FCBN 4–2.5%FCBN 4–2.5%FCBN 115 150 150 165 200 245 13B 17D 17D 37.5 50 75 100 37S5H 50S5H 75S5H 100S5H 3252. 3953. 5353. 6955. 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 4–2.5%FCBN 150 150 150 150 325 350 450 640 18D 18D 21D 22D 167 167S5H 10806. 4–2.5%FCBN 150 975 24D FCBN: full capacity taps below normal LUGS: furnished by customer Buck and Boost transformers are isolating transformers that have 120 X 240 volt primaries and either 12/24 or 16/32 volt secondaries. When used as isolating transformers they carry the full load stated on the nameplate. By special interconnection of the windings, an autotransformer is obtained. When used this way for bucking or boosting small voltage changes, the kVA load they carry is large compared to their physical size. See bulletin 7414PD9301 (D-FAX 2543) for application tables and wiring diagrams for buck and boost transformers. NOTE: When used to supply a 3-phase, 4-wire load, the source must be 3-phase, 4-wire. Single Phase – 120 x 240 V Primary 60 Hz UL/cUL Listed. Copper Windings. Catalog Numbersq kVA 12/24 V Secondary 16/32 V Secondary Price Degree C Temp. Rise .05 .10 .15 .25 .50 .75 1.0 1.5 2.0 3.0 50SV43A 100SV43A 150SV43A 250SV43B 500SV43B 750SV43F 1S43F 1.5S43F 2S43F 3S43F 50SV46A 100SV46A 150SV46A 250SV46B 500SV46B 750SV46F 1S46F 1.5S46F 2S46F 3S46F $ 98. 117. 131. 156. 200. 263. 322. 395. 510. 705. 55 55 55 80 80 115 115 115 115 115 Weight k (Pounds) Enclosure ck 4.2 4.5 6.2 10.5 13.8 15.5 21.2 30.1 39.1 60 1A 2A 3A 4A 5A 6A 7A 8A 9A f 12 TRANSFORMERS f Dimensions: 14.5" high x 8.6" wide x 6.5" deep. k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. q Catalog Numbers shown in bold type are available from Distribution Center. a When 240 volt connection is used, there will be 3–5% taps, 1 above and 2 below 240 volts. c For enclosure styles, see dimensions table, page 12-8. FCBN: full capacity taps below normal LUGS: furnished by customer j 15S40H is UL Listed only. k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. For an index of all product information available via D-FAX™ for low voltage transformers, request D-FAX TM number 09. For additional information, reference Selection Guide No. 7400CT9601 or D-FAX TM number 1673 (pages 1-20) and 2284 (pages 21-41). 12-2 © 2000 Square D All Rights Reserved PE2 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type 600 Volts and Below Special Voltage Transformers, Shielded Isolation Transformers Class 7400 Special Voltage Transformers — Shielded and Non-shielded Square D offers special voltage transformers built to customer specifications. Many options such as lower sound level, copper windings, special frequency, etc. are available but not listed below. Contact your nearest Square D/Schneider Electric sales office for details. Three Phase – Shielded and Non-shielded UL Listed 15 All two-winding transformers are “isolating” or “insulating” because there is no electrical connection between the primary and secondary windings. Additionally, critical equipment might require an electrostatic shield be furnished between primary and secondary to attenuate some of the source line interference and common-mode noise. Protection from transverse-mode transients is obtained by adding surge suppressors and filters to the shielded isolation transformer. These products are listed on page 12-6. Product Data Bulletin 7400PD9202 (D-FAX 2539) describes technical details of shielded and filtered transformers. 30 45 75 112 150 225 300 Price Degree C Temp. Rise Weight (Pounds)k Enclosure ck $ 2602. 2862. 3203. 3523. 4003 4403. 5954. 6549. 7956. 8752. 9777. 10754. 13442. 14786. 17964. 19760. 150 200 17D 150 250 17D 150 340 18D 150 500 19D 150 750 21D 150 800 22D 150 1025 24D 150 1450 25D Electrostatic Shield is indicated by the letters IS at the end of the catalog number. To Complete Catalog Number: Single Phase–Shielded and Non-shielded 1. Select the voltage required from chart 2. UL Listed through 167 kVA cUL Listed through 10 kVA kVA Catalog Number Price 1 1 1.5 1.5 2 2 1S( )F 1S( )FIS 1.5S( )F 1.5S( )FIS 2S( )F 2S( )FIS $ 518. 569. 741. 831. 831. 901. 7 6, 7 None 6, 7 None 6, 7 115 115 115 115 115 115 3 3 5 5 7.5 7.5 3S( 3S( 5S( 5S( 7S( 7S( 901. 951. 1151. 1251. 1531. 1640. None 6, 7 None 6, 7 None 6, 7 115 115 115 115 115 115 60 60 110 110 135 135 10A 10A 13B 13B 13B 13B )F )FIS )F )FIS )F )FIS Stocked Degree C Weight Enclosure Voltage Codes Temp. Rise (Pounds)k ck 21.2 21.2 30.1 30.1 39.1 39.1 7A 7A 8A 8A 9A 9A 10 10 15 15 25 25 10S( 10S( 15S( 15S( 25S( 25S( )F )FIS )H )HIS )H )HIS 1903. 2043. 2591. 2851. 3402. 3742. None 3, 6, 7 None 3, 6, 7 None 3, 6, 7 115 115 150 150 150 150 150 150 205 205 240 240 13B 13B 17D 17D 17D 17D 37.5 37.5 50 50 37S( 37S( 50S( 50S( )H )HIS )H )HIS 3755. 4130. 4568. 5021. None 3 None 3 150 150 150 150 325 325 350 350 18D 18D 18D 18D To Complete Catalog Number: 2. Insert the voltage code number in place of the ( ) in the catalog number. Chart 2 Voltage Code Primary Secondary Full Capacity Taps 127 153 74 10 99 600 Delta 600 Delta 600 Delta 600 Delta 480 Delta 600Y/347 480 Delta 480Y/277 240 Delta 480 Delta 4-2.5% 2+24-2.5% 2+24-2.5% FCBN 4-2.5% FCBN 4-2.5% 2+2- 1834 1841 1768 2463 3tj 480 Delta 480 Delta 480 Delta 480 Delta 480 Delta 600 Delta 600Y/347 416Y/240 400Y/231 208Y/120 4-2.5% 2+24-2.5% 2+24-2.5% 2+24-2.5% 2+26-2.5% 2+4- 911 918 884 890 441 240 Delta 240 Delta 240 Delta 240 Delta 208 Delta 600 Delta 600Y/347 480 Delta 480Y/277 600 Delta 2-5% 1+12-5% 1+12-5% 1+12-5% 1+12-5% 1+1- 447 414 66 85j 208 Delta 208 Delta 208 Delta 208 Delta 600Y/347 480 Delta 240 Delta 208Y/120 2-5% 1+12-5% 1+12-5% FCBN 2-5% FCBN t Use pricing from page 12-3 for non-shielded units. j Use pricing below for shielded units. 1. Select the voltage required from chart 1. Three Phase 480 V Delta Primary 2. Insert the voltage code number in place of the ( ) in the catalog number. Chart 1 TRANSFORMERS Catalog Number 15T( )H 15T( )HIS 30T( )H 30T( )HIS 45T( )H 45T( )HIS 75T( )H 75T( )HIS 112T( )H 112T( )HIS 150T( )H 150T( )HIS 225T( )H 225T( )HIS 300T( )H 300T( )HIS kVA Voltage Code Primary Secondary Full Capacity Taps 6 7 60 f 9 1292 120x240 208 208 208 208 120/240 120/240 120/240 208 277 None None 2-5% FCBN None None 8 61 f 3f 72 78 277 277 240x480 480 480 120/240 120/240 120/240 208 277 None 2-5% FCBN 6-2.5% 2+4None None k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. c For enclosure styles, see Dimensions Table, page 12-8. FCBN = Full capacity below normal Lugs: Furnished by customer. Taps on transformers 225 kVA and larger may vary in 3% to 5% steps to obtain best design. f Taps are available on transformers 10 kVA and larger. 208Y/120 V Secondary 60 Hz with Electrostatic Shield, UL Listed kVA 9 15 30 45 75 112.5 150 225 300 500 Catalog Number q 9T2FIS 15T3HIS 30T3HIS 45T3HIS 75T3HIS 112T3HIS 150T3HIS 225T3HIS 300T3HIS 500T68HIS Price Stocked Degree C Weight Enclosure Voltage Codes Temp. Rise (Pounds)k ck $ 2201. 2741. 3452. 4152. 6254. 2–5%FCBN 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 115 150 150 150 150 235 200 250 340 500 14C 17D 17D 18D 19D 8143. 10389. 13913. 18261. 27930. 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 6–2.5%2 + 4– 4–2.5%2 + 2– 150 150 150 150 150 815 800 1025 1450 2100 21D 22D 24D 25D 30D 208 V Delta Primary 208Y/120 V Secondary 60 Hz with Electrostatic Shield, UL Listed 9 15 30 45 75 9T85FIS 15T85HIS 30T85HIS 45T85HIS 75T85HIS $ 2201. 2741. 3452. 4152. 6254. 2–5%FCBN 2–5%FCBN 2–5%FCBN 2–5%FCBN 2–5%FCBN 115 150 150 150 150 235 200 250 340 500 14C 17D 17D 18D 19D 112.5 150 225 300 500 112T85HIS 150T85HIS 225T85HIS 300T85HIS 500T85HIS 8143. 10389. 13913. 18261. 27930. 2–5%FCBN 2–5%FCBN 2–5%FCBN 2–5%FCBN 2–5%FCBN 150 150 150 150 150 815 800 1025 1450 2100 21D 22D 24D 25D 30D 12 q Catalog Numbers shown in bold type are available from Distribution Center. k Not for construction. Contact your nearest Square D/Schneider Electric sales office for certified prints. c For enclosure styles, see Dimensions Table, page 12-8. FCBN = Full capacity below normal Lugs: Furnished by customer. Taps on transformers 225 kVA and larger may vary in 3% to 5% steps to obtain best design. 12-4 © 2000 Square D All Rights Reserved PE2 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Dry Type 600 Volts and Below Enclosures Class 7400 Enclosure Styles Table 1: Enclosure Dimensions and Accessories (Note 1) Enclosure Number/ Style Style A–NEMA Type 3R Rated Style B– NEMA Type 3R Rated Style C –NEMA Type 3R Rated IN mm Depth IN mm Mtg. Weathershield Wall Mounting Bracket Ceiling Mounting Bracket Insulation Class °C A 5 127 4.47 114 3.44 87 Wall Note 2 Note 3 — 105 2 A 5.5 140 4.47 114 3.44 87 Wall Note 2 Note 3 — 105 3 A 5 127 4.85 123 3.75 95 Wall Note 2 Note 3 — 105 4 A 5.5 140 5.23 133 4.06 103 Wall Note 2 Note 3 — 130 5 A 6.19 157 6.19 157 4.69 119 Wall Note 2 Note 3 — 130 6 A 6.69 170 6.19 157 4.69 119 Wall Note 2 Note 3 — 180 7 A 8.13 270 6.94 176 5.31 135 Wall Note 2 Note 3 — 180 8 A 8.25 210 8.68 220 6.56 167 Wall Note 2 Note 3 — 180 9 A 9.56 243 8.68 220 6.56 167 Wall Note 2 Note 3 — 180 10 A 10.5 267 8.62 219 6.5 165 Wall Note 2 Note 3 — 180 11 A 12.56 319 8.62 219 6.5 165 Wall Note 2 Note 3 — 180 12 C 13.5 343 14.75 375 9 229 Wall Note 2 Note 3 — 180 13 B 14.75 375 248 11.75 298 Wall Note 2 Note 3 — 180 14 C 14.75 375 19.1 485 12.25 311 Wall Note 2 Note 3 — 180 15 B 20 508 15 381 13.5 343 Wall Note 2 Note 3 — 180 Note 3 — 16 18 19 20 21 22 23 24 25 26 9.75 C 22 559 25 635 13.5 343 Wall Note 2 D 27 686 20 508 16 406 Floor WS363 180 WMB361–362 CMB363 220 E 27 686 20 508 16 406 Floor Note 5 WMB361–362 CMB363 220 D 30 762 20 508 20 508 Floor WS363 WMB363–364 CMB363 220 E 30 762 20 508 20 508 Floor Note 5 WMB363–364 CMB363 220 D 30 762 30 762 20 508 Floor WS364 WMB363–364 CMB364 220 E 30 762 30 762 20 508 Floor Note 5 WMB363–364 CMB364 220 D 37 940 30 762 20 508 Floor WS364 WMB363–364 CMB364 220 WMB363–364 CMB364 E 37 940 30 762 20 508 Floor Note 5 D 37 940 30 762 24 610 Floor WS364 N/A CMB364 220 220 E 37 940 30 762 24 610 Floor Note 5 N/A CMB364 220 D 43.75 1111 32 813 27 686 Floor WS380 N/A CMB380 220 E 43.75 1111 32 813 27 686 Floor Note 5 N/A CMB380 220 E 48 1219 29.5 749 Floor Note 5 N/A N/A 220 220 1219 48 D 49.5 1257 35 889 28.5 724 Floor WS381 N/A CMB381 E 49.5 1257 35 889 28.5 724 Floor Note 5 N/A CMB381 220 D 49.5 1257 41 1041 32 813 Floor WS382 N/A N/A 220 E 49.5 1257 41 1041 32 813 Floor Note 5 N/A N/A 220 D 57.5 1461 41 1041 32 813 Floor WS382 N/A N/A 220 D 60 1524 56 1422 36 914 Floor WS370A N/A N/A 220 E 60 1524 56 1422 36 914 Floor Note 5 N/A N/A 220 29 D 68 1727 56 1422 36 914 Floor WS370A N/A N/A 220 30 D 71 1803 48 1219 36 914 Floor WS383 N/A N/A 220 31 D 74 1880 56 1422 40.5 1029 Floor WS384 N/A N/A 220 32 F 94 2388 56 1422 54 1372 Floor Note 4 N/A N/A 220 33 F 94 2388 72 1829 54 1372 Floor Note 4 N/A N/A 220 34 F 94 2388 84 2134 54 1372 Floor Note 4 N/A N/A 220 35 F 94 2388 96 2438 54 1372 Floor Note 4 N/A N/A 220 28 Style E–IP55 Rated Width mm 1 17 Style D –NEMA Type 2 Rated Converts to NEMA Type 3R with Weathershield Height IN 12 TRANSFORMERS Note 1: These dimensions are not for construction. Contact your nearest Square D/Shneider Electric sales office for certified prints. Note 2: Transformer is NEMA Type 3R Standard. Weathershield not required for outdoor use. Note 3: Wall mounting brackets are a standard part of transformer enclosure. Accessory not required. Note 4: Special outdoor construction required for NEMA Type 3R applications. Contact your nearest Square D/Schneider Electric sales office for details. Note 5: Indoor/outdoor enclosure standard. Weathershield not required. N/A: Wall mounting/ceiling mounting bracket not available due to weight of these parts. Style F–NEMA Type 1 Rated 12-8 © 2000 Square D All Rights Reserved PE2 Discount Schedule 3/00 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com