PowerCube Transformers ™ Energy Efficiency & Cost Savings As the pioneer of critical power distribution technology, ONYX leads the industry in high efficiency transformers. Backed by over 35 years of magnetics experience, ONYX has one of the largest installed bases of high efficiency transformers supporting global applications where lower operating costs, energy savings and the environment are a priority. Lower Operating Costs ONYX transformers are designed to deliver optimal high efficiency for lower operating costs. Exceeding national efficiency standards (NEMA TP-1), PowerCube™ transformers deliver true energy savings under both linear and non-linear loads. TP-1, US mandatory standard, demonstrates energy savings that quickly pay back the initial cost of replacing an obsolete power transformer. ONYX PowerCube™ incorporates advanced engineering, meticulous construction and the finest materials to surpass TP-1 efficiency while in normal operating load range. Test Reports Verified to National Standards To verify performance of actual efficiency, all ONYX transformers are provided with a serialized test report to validate performance. Engineering Capabilities ONYX Power engineers are experienced in a variety of transformer requirements including: Delta Wye, Quad-Wye, Delta Zig-Zag, Dual Zig Zag, autotransformers and medium voltage transformers. Quick turnaround guaranteed – on all PowerCube™ designs, quotations and custom ratings Contact Us: +1.714.513.1500 | www.onyxpower.com | www.smithspower.com PowerCube™ Benefits Reduced energy costs Lower energy consumption Reduced greenhouse emissions Eco-friendly design maximizes recycling methods for sustainability Meets or exceedsTP-1 efficiency standards LEED certified building criteria Long term warranty available UL Listed PowerCube™ Features Lower heat generation thus less cooling capacity required Natural convention cooling 240°C thermal shielding between windings-for extra margin of safety and extended operating life Welded tap connections-eliminate “hot spots” Hinged front port access to power connections Customizable load level productivity maximization Oversized neutral for non-linear loads Real time efficiency status monitoring Copper wound construction – better conducting and more resilient than aluminum Dual electrostatic shield – attenuates high frequency noise PowerCube™ Options ONYX offers over 800 different PowerCube™ configurations. Contact our technical support team at +1.714.513.1500 to to discuss the right PowerCube™ option to support your network. Infrared transparent window for safe routine thermal scanning Metering connection port SPD (Surge Protection Device) integration Temperature rise at 130°C, 115°C, 105°C and 80°C Temperature monitor Zero and thirty degree phase shift Thermal warning and shutdown sensors PowerLogic and WaveStar monitoring systems NEMA 3R enclosure Specifications Ratings Operating Conditions NEMA 1 (H x W x D inches) kVA ratings 75-1000 kVA Operating Temperature: 0°C to 40°C 75 kVA 42 x 35 x 21 K Factor: specifiable K1 through K20 Storage Temperature: -10°C to 40°C 100 kVA 42 x 35 x 21 6 Compensation taps (4 FCBN, 2 FCAN) 50 Hz Operating Range 47-53 Hz 125 kVA 50 x 40 x 28 Input: 3-phase, 3 wire plus ground 60 Hz Operating Range 57-62 Hz 150 kVA 50 x 40 x 28 Input Voltage @ 50 Hz: 415 or 380 V @ 60 Hz: 600, 480 or 208V Relative Operating Humidity: 90% non-condensing 225 kVA 63 x 49 x 30 Output: 3-phase, 4 wire plus ground Operation Efficiency: 98% typical 300 kVA 63 x 49 x 30 Output Voltage @ 50 Hz: 415/240 or 380/220V @ 60 Hz: 600, 480 or 208/120V 500 kVA 66 x 51 x 44 Impedance: 2.0-4.5% average ± 0.25% 750 kVA 1000 kVA 72 x 66 x 44 72 x 66 x 44 Contact Us: +1.714.513.1500 | www.onyxpower.com | www.smithspower.com