Application
EV100 contactors are designed for use in DC applications, with battery or
rectified power. They perform power switching functions for traction drives as
well as pump motor and other electric vehicle power switching operations.
The contactors have been successfully applied to meet Underwriter’s
Laboratories. They are listed under U/L file number AU2422.
Specifications
100 Amp Contactors
Rating / Type
IC4482CTTA104
100A - DPDT
IC4482CTTA100
100A - SPNO
Make and Interrupt Rating
Make
900 Amps
12-84VDC
Interrupt
900 Amps
12-84VDC
Make
900 Amps
12-84VDC
Interrupt
900 Amps
12-84VDC
80 Amps
100 Amps
400 Amps
600 Amps
Duty Cycle Rating
100%
Continuous
50%
20 Minutes
5%
30 Seconds
2%
5 Seconds
150 Amp Contactors
Rating / Type
IC4482CTTA154
150A - DPDT
IC4482CTTA150
150A - SPNO
IC4482CTTA158
150A - DPDT (HD Tips)
IC4482CTTA168
150A - SPDT (HD Tips)
Make and Interrupt Rating
Make
1500 Amps
12-84VDC
Interrupt
1500 Amps
12-48VDC
Interrupt
1100 Amps
72-84VDC
Make
1500 Amps
12-84VDC
Interrupt
1500 Amps
12-48VDC
Interrupt
1200 Amps
72-84VDC
Make
1500 Amps
12-84VDC
Interrupt
1500 Amps
12-48VDC
Interrupt
1100 Amps
72-84VDC
Make
1500 Amps
12-84VDC
Interrupt
1500 Amps
12-48VDC
Interrupt
1100 Amps
72-84VDC
100 Amps
150 Amps
600 Amps
900 Amps
Duty Cycle Rating
100%
Continuous
50%
20 Minutes
5%
30 Seconds
2%
5 Seconds
300 Amp Contactors
Rating / Type
IC4482CTTA304
300A - DPDT
IC4482CTTA300
300A - SPNO
IC4482CTTA368
300A - SPDT (HD Tips)
Make and Interrupt Rating
Make
2000 Amps
12-84VDC
Interrupt
2000 Amps
12-48VDC
Interrupt
1500 Amps
72-84VDC
Make
2000 Amps
12-84VDC
Interrupt
1500 Amps
12-48VDC
Interrupt
1500 Amps
72-84VDC
Make
2000 Amps
12-84VDC
Interrupt
2000 Amps
12-48VDC
Interrupt
1500 Amps
72-84VDC
225 Amps
300 Amps
1200 Amps
1800 Amps
Duty Cycle Rating
100%
Continuous
50%
20 Minutes
5%
30 Seconds
2%
5 Seconds
400 Amp Contactors
Rating / Type
IC4482CTTA400
400A - SPNO
Make and Interrupt Rating
Make
2000 Amps
12-84VDC
Interrupt
2000 Amps
12-48VDC
Interrupt
1500 Amps
72-84VDC
( Note: 400 Amp uses Tin Oxide & Silver Tips)
250 Amps
400 Amps
1300 Amps
1900 Amps
Duty Cycle Rating
100%
Continuous
50%
15 Minutes
5%
30 Seconds
2%
5 Seconds
Rev 01/16
Typical Power Terminal Forms
AA
Coil
Number
112
118
124
136
142
142
160
176
176
212
218
224
248
280
324
SPNO
AH
SPDT
BA
DPDT
FR
Volts
12 VDC
18VDC
24 VDC
36 VDC
36 VDC
48 VDC
60 VDC
72/80 VDC
72 VDC
12 VDC
18 VDC
24 VDC
48 VDC
80 VDC
24 VDC
Duty
Int.
Int.
Int./Cont.
Int.
Cont.
Int.
Int.
Int.
Cont.
Cont.
Cont.
Cont.
Cont.
Cont.
Cont.
Coil Burden
100A 150/300/400A
5.8A
4.9A
3.6A
3.1A
1.7A
1.9A
1.0A
1.8A
1.1A
0.8A
1.1A
1.4A
NA
0.8A
0.6A
0.6A
0.6A
0.5A
3.3A
3.7A
2.4A
2.0A
NA
1.0A
0.8A
0.8A
0.5A
--1.9A
---
Outline (For Reference Only)
6.09
[154.7]
.28
[7.1]
5.53
[140.5]
2.74
[69.6]
1.50 [38.1] - 100A
1.50 [38.1] - 150A
1.75 [44.5] - 300A
2.20
[55.9]
1.10
[27.9]
.27
[6.9]
DPDT
M AXIM UM HEIGHT S
3.66
[93.0]
.28
[7.1]
3.10
[78.7]
2.74
[69.6]
1.50 [38.1] - 100A
1.50 [38.1] - 150A
1.75 [44.5] - 300A
2.20
[55.9]
1.10
[27.9]
DPDT
100A 150A
300A
4.31
4.88
4.88
[109.5] [123.9] [123.9]
SPDT
100A 150A
300A
NA
4.88
4.88
[123.9] [123.9]
SPNO
100A 150A 300/400A
3.89
4.45
4.45
[98.8] [113.0] [113.0]
DIMENSIONS - INCHES [MM]
.27
[6.9]
SPDT (SOLID COVER)
SPNO (OPEN TOP)
MOUNTING HOLES (6)
.281 [7.1] X .328 [8.3] SLOTS
FOR 1/4-20 OR M6 BOLTS
POWER TERMINALS - M8 X 1.25
COIL TERMINALS - M4 X .7
Ordering Information
IC4482CTTA154
Type
See Table
FR
Terminal Form
See Table
124
Coil Number
See Table
X
Interlock
X – None
A – 2NO/2NC
N
Arc Shields
N – None
S - Yes
Note: Contact FSIP for replacement parts or if other contactor power terminal forms and/or voltages are required for your application.