• Designed to be used in the workshop as well as in the laboratory, can solve various measuring problems at a very competitive price/performance ratio. • Available with fixed or interchangeable contact. • IP 65 protection degree against dust and fluids. BORE GAUGES LINE FORKS AND RING GAUGES • 8 models of full-bridge (LVDT) and half-bridge (HBT) probes with clamping diameter 8 mm or 3/8” and measuring range ± 1 mm (.04”), to be used especially with mechanical transmission devices such as TESTAR AMA, Quick Block and Quick Set. TRANSDUCERS AND MEASUREMENT TRANSMISSIONS PENCIL PROBES 59,8 mm (2.35”) (*) 84,3 mm (3.32”) Ø Ø (*) 73,3 mm (2.89”) (*) Dimensions referred to the electrical zero QUICK PROBE - 1 59,8 mm (2.35”) INTERFACE BOXES FOR DATA ACQUISITION QUICK PROBE WITH INTERCHANGEABLE CONTACT SOFTWARES QUICK PROBE WITH FIXED CONTACT INDICATORS AND ELECTRONIC DISPLAY UNITS BENCH GAUGES • Compatible with any electronics already present on the market. TRANSDUCERS AND MEASUREMENT TRANSMISSIONS TECHNICAL SPECIFICATIONS / ORDER CODES Mechanical specifications MODEL SF100 LVDT SH100 HBT WITH FIXED CONTACT BORE GAUGES LINE MEASURING RANGE MAX. OVERTRAVEL PRETRAVEL LINEARITY ERROR REPEATABILITY THERMAL DRIFT TEMPERATURE RANGE MEASURING FORCE GUIDE CABLE LENGTH STANDARD CONNECTOR PROTECTION LEVEL OPTIONAL CONTACTS Not applicable SF101 LVDT SH101 HBT WITH INTERCHANGEABLE CONTACT ± 1 mm (.04”) 1.5 - 2.5 mm (.06” - .10”) 1.2 - 1.5 mm (.05” - .06”) ≤ 5 µm (0.25%) ≤ 0.1 µm ≤ 0.25 µm/°C -10°C/ +65°C 0.8 N ± 25% Bushing 2m Lumberg SV 50/6 (DIN 45322) IP65 Available (see Red Crown section) FORKS AND RING GAUGES Full-bridge (LVDT) electrical specifications Trade name Calibration frequency (KHz) Calibrated at Max. current (mA RMS) I/O phase shift Sensitivity (mV/V/mm) Cable outlet Order Code SF100 axial SF101 7,5 3,5V RMS with load 1 MOhm//360pF 12 ≤ 10° 230 ±1% ø 3/8” ø 8 mm 3424011050 3424011500 ø 8 mm 3424011000 ø 3/8” 3424011550 BENCH GAUGES Half-bridge (HBT) electrical specifications INDICATORS AND ELECTRONIC DISPLAY UNITS Trade name Calibration frequency (KHz) Calibrated at Max. current (mA RMS) I/O phase shift Sensitivity (mV/V/mm) Cable outlet Order Code SH100 axial SH101 7,5 3,5V RMS with load 2 KOhm ±0,1% 10 ≤ 10° 73,75 ±1% ø 3/8” ø 8 mm 3424014050 3424014500 ø 8 mm 3424014000 ø 3/8” 3424014550 Half-bridge (HBT) electrical specifications of the version compatible with amplifiers of TESA Trade name Calibration frequency (KHz) Calibrated at Max. current (mA RMS) I/O phase shift Sensitivity (mV/V/mm) Cable outlet Order Code SH100 SH101 13 3V RMS with load 2 KOhm ±0,1% 7 ≤ 3° 73,75 ±1% ø 8 mm axial 3424014600 INTERFACE BOXES FOR DATA ACQUISITION DESCRIPTION QUICK PROBE SF/SH USER MANUAL 3424014700 ORDER CODE D4340012X1 (*) (*) X = I (Italian); G (English); D (German); E (Spanish); F (French) For a full list of address locations, please consult the Marposs official website D6Q00501G0 - Edition 10/2007 - Specifications are subject to modifications © Copyright 2007 MARPOSS S.p.A. (Italy) - All rights reserved. SOFTWARES MARPOSS, and Marposs product names/signs mentioned or shown herein are registered trademarks or trademarks of Marposs in the United States and other countries. The rights, if any, of third parties on trademarks or registered trademarks mentioned in the present publication are acknowledged to the respective owners. Marposs has an integrated system to manage the Company quality, the environment and safety, attested by ISO 9001, ISO 14001 and OHSAS 18001 certifications. Marposs has further been qualified EAQF 94 and has obtained the Q1-Award. QUICK PROBE - 2