BEGA Installation and Technical Information 2413P Wall washers with asymmetrical distribution Tools Requir ed: Required: Phillips medium screwdriver Adjustable wrench 3mm hex key Dimensions B UL listed, suitable for wet locations. A C A: 10-1/4 " B: 8-7/16 " C: 9-5/8 " Pr otection Class: IP 65 Protection Weight: 10.6 lbs. Notice to Installer for 2413P: 1. For wall applications only. 2. Mounts directly to standard recessed 4” octagonal wiring box (by others), using mounting kit (supplied). 3. In conformance with UL Standard 1598, a silicone based sealant must be used between luminaire and supporting wall. 4. For up or down orientation. Mounting plate/ Fixture back housing Adaptor plate 4" Standard octagonal wiring box 2413P - installation: 1. Loosen (4) 3mm hex screws and remove faceplate with lens. 2. Loosen rear screw on the fixture canopy and remove mounting plate. 3. Install (2) long 8-32 x 1 1/2” screws (provided) in the back of the adapter plate as shown. 4. Attach adaptor plate to wiring box using (2) 8-32 x 1/2” screws provided. Feed luminaire wires through luminaire mounting plate and adaptor plate. 5. Make supply wiring and luminaire wiring connections in the octagonal wiring box: MAIN VOLTAGE SUPPLY WIRE TO BLACK LUMINAIRE WIRE NEUTRAL (COMMON) SUPPLY WIRE TO WHITE LUMINAIRE WIRE GREEN GROUND WIRE TO GREEN LUMINAIRE WIRE 6. Note orientation labels on luminaire mounting plate. Test to make sure the mounting plate is level by adjusting the adaptor plate, if needed. 7. Place a small bead of silicone around the back side of the mounting plate that will come in contact with the finished wall (exterior applications only). 8. Attach mounting plate to adaptor plate over the mounting screws using the (2) acorn nuts provided in the mounting kit. Tighten the nuts to back the screws into the wiring box and secure the plate to the box. 9. Mount luminaire to mounting plate and tighten canopy screw to secure luminaire. NOTE: USE ARROWS ON THE BACK OF THE LUMINAIRE TO FIND FIXTURE ORIENTATION. 10. Insert lamp. 11. Replace faceplate with lens attached, making sure the gasket is seated properly. The stepped side of the glass lens is the side facing out. Tighten (4) hex screws. Wiring box screw Mounting screws Relamping/Mainten ance Relamping/Maintenance Acc essories Accessories Replacement Par ts Parts Loosen set screw and remove trim and reflector. Relamp. Clean luminaire and lens using only solvent-free cleansers. Replace trim and reflector. Tighten set screw. Please refer to the appropriate accessory installation sheet for further instruction when applicable. Description Part No Lens Reflector Lens gasket Lampholder Ballast (120V-277V) 140278 Consult factory 830655 74140 75390 Lamp: (1) 42W CF triple-4p Philips : PL-T 42W/4P/ALTO Osram/Sylvania : CF42DT/E GE : F42TBX In the interest of product improvement, BEGA reserves the right to make technical changes without notice. BEGA 1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA/US 2008 2413P 11/4/2008