ADA 8x8 Central Unit AUDICO SYSTEMS OY P.O.Box 39 Ruunikkokatu 2 Fi 20381 Turku Finland Tel. + 358 –2 – 415 5400 Fax. + 358 –2 – 415 5450 audico@audico.fi www.audico.fi Notes V 1.01 Audico Avec digital Public Address and Voice Evacuation system AUDICO ADA 8x8 CENTRAL UNIT The real heart of the digital Audico Avec, Public Address and Voice Evacuation system, is the Audico ADA 8x8 central unit. The ADA 8x8 is a very effective and compact unit. It has versatile analog and digital audio inputs, effective digital signal processing circuitry and matrix, built-in prerecorded spoken message player and even 8 digital 150W power amplifiers. The Audico Avec accommodates also system surveillance according to EN 60849 standard. It’s certified by authorized certification body. All this in a single 2U high 19” device. • • • • • • • • • • • • • • • • EN 60849 certified Voice Evacuation system 8 independent 150W @ 8 Ohms amplifiers Digital matrix 7x8 7 analog audio inputs, mic/line level 2 digital SPDIF inputs Built-in message/advertisement player Messages in USB-memory-stick Calendar and timer functions Phantom voltage for microphones 8 control contact inputs 8 control contact output System bus for top hierachy level devices Local bus for lower hierachy devices Efficient signal processing (DSP) Volume and source controls on users’ panel RS 232 serial input for external control Audico Avec is configured using intuitive and easy to use Avec software, the file is finally downloaded to the ADA 8x8 MAINS INLET AND FUSES 24VDC OPERATION VOLTAGE OUTPUT ADA 8x8 is connected to 230V operation voltage using standard mains plug. The 24DC power output is used to supply power to the ALT 8x8 line transfer unit. The same voltage is used also for priority voltage. Priority voltage is used to bypass possible attenuators in rooms during paging or alarm to ensure the message is heard everywhere in the building. ADA 8x8 contains two separate parallel low voltage power units. Both power supplies have dedicated fuse at the rear panel. ADA 8x8 must be equipped with external UPS device when erecting a system according to the EN 60849 standard. Fuse size is 3,15AT SPEAKER OUTPUTS ADA 8x8 contains 8 pcs 150W digital power amplifiers. 8 Ohms loudspeakers may be connected directly to the speaker outputs. When 50-70-100V speakers are used the ADA 8x8 must be equipped with ALT 8x8 line transfer unit. It converts the 8 Ohms outputs to desired line voltage. DIGITAL OPTICAL INPUTS AND OUTPUTS (SPDIF) ADA 8x8 can handle digital audio signals directly. Digital audio is brought to ADA 8x8 by using optical SPDIF-cable. The optical inputs are activated by configuration software, the corresponding analog inputs must be disabled. SPDIF input 1 is parallel to analog inputs 1 and 2, SPDIF 2 is parallel to analog inputs 5 and 6. The ALT 8x8 provides also priority voltage outputs, individually for each line (24VDC). RS-232 INTERFACE FAN The RS232 interface at the rear is used for monitoring the running of the ADA 8x8’s operation system. Suitable software is for example Windows Hyperterminal. ADA 8x8 can be controlled thru USB port using special RS232/USB adapter. The ADA 8x8 is equipped with a fan. The rotation of fan is also monitored and any fault is reported to surveillance system. SYSTEM & LOCAL OVERRIDE AUDIO OUT MIC/LINE INPUTS Both paging and alarm signals can be configured to these outputs. The outputs are mainly intended to feed paging audio to external amplifers or other systems. 7 pcs microphone/line inputs.The connector is removable 3-pins plug. Each input has own input sensitivity trimmer. The mic/line selection is done using the configuration software. CTRL ALT 8x8 CONTROL DATA TO ALT 8x8 SYSTEM BUS & LINK The ALT 8x8 delivers priority voltage to wanted lines according the data from ADA 8x8. Audico Avec devices are connected together using either system or local bus. The devices connected to the system bus can be used to control all ADA 8x8’s in a single installation. Maximum number of devices in a single bus is 32. DEVICE ADDRESS DIP-SWITCH Every ADA 8x8 in a system must have own individual device address in the same order as they appear on the configuration software. The first main unit has address one, then two etc. CONTROL OUTPUTS LOCAL BUS The local bus is used to connect devices that are intended to be used only locally within the cover area of a single ADA 8x8. Typically local paging unit and volume controllers are such locally operated devices. The control outputs may be configured to activate on diverse situations, like paging, alarm, fault-indication, firebell muting etc. The output is open-collector type. USB-MEMORY STICK CONNECTOR CONTROL INPUTS The control inputs may be used to active different ADA 8x8 actions like activate a paging, change preset, play message, alarm etc. The alarm and other messages are stored in wavformat to a USB-memory stick. The stored sound files can be played as chime, alarm or information message triggered by timer, paging, control input or a fault etc. There is another USB - jack inside the ADA 8x8 for non-removable messages. ADA 8x8 simplified block diagram V 1.01 Audico Avec digital Public Address and Voice Evacuation system ADA 8x8 CENTRAL UNIT TECHNICAL CHARACTERISTICS Audico code EAN code Operation voltage Max power 30010 6430029190019 Signal processing and routing characteristics 8 digital power 150W @ 8 Ohms amplifiers 7 analog audio inputs, configurable either to mic or line level Phantom-voltage for electret microphones 2 SPDIF digital stereo inputs 2 SPDIF digital stereo outputs Internal message player, security messages in internal memory, unlimited number of messages in USB memory stick. (wav) Input channels digital signal processing (DSP), 7 channels Input level, mic or line Type of signal: digital/analog Parametric equalizer, 3 band Digital routing Level control Output channels digital signal processing (DSP), 8 channels Tone control Parametric equalizer, 5 band High pass filter, frequency freely selectable 12 or 24 dB/octave, filter: Butterworth, Linkwitz- Riley or Bessel Delay max 4ms Compressor /limiter Volume control Connection buses and I/O’s Local bus (CAT5) for paging and control devices operational within one ADA 8x8 only System bus (CAT5) for paging and control devices operational over whole system, max 32 devices System bus link connector for chaining to next ADA 8x8 Front panel USB connector for configuration file down/upload Rear panel and internal USB jacks for message memory sticks 8 control contact inputs, operation configurable 8 control contact outputs, operation configurable Priority data for controlling the ALT 8x8 line transfer unit 230VAC 950W Required maximum alarm-on UPS capacity is 1kVA Required ready-state UPS capacity is 200VA (system on but no audio signal) Analog audio inputs 7 pcs Control I/O’s 8 / 8 pcs (open-collector) SPDIF in/out 2 pcs System bus Local bus max 32 device, CAT 5 max 32 device, CAT 5 Outputs 8 pcs each 150W@8 Ohms The ADA 8x8 is Rohs-compliant, it is tested according all relevant safety and electromagnetic compatibility standards (EMC). The Audico Avec product family is certified according to EN-60849 standard (Sound System for Emergency Purposes). Dimensions WxHxD 483 x 88 x 380 mm Carton W x H x D Volume Weight / net Weight / gross 540 x 460 x 170 mm 0,042m3 8,5 kg 9 kg System operation System is expandable by adding required number of ADA 8x8 units. Up to 256 speaker lines / paging zones Possibility to use local programme sources in any ADA 8x8. System surveillance: Device and system monitoring according to EN-60849 standard Automatic switch-over to a another ADA 8x8 if master ADA fails Power supply voltage and temperature monitoring Fan rotation monitoring Requirement for Voice Evacuation System’s Main User Standard EN-60849 sets also guidelines for the user of the installed system. The main user must take care of system maintenance, testing, keep the logbook and ensure all other users are well trained to use the system. We have prepared a booklet guiding the user as well the installation and service companies to set-up and run a system according the EN standard. Accessories - mains cable with Schuko-plug - USB A-B cable for downloading - 1 GB USB memory stick - installation and operation manuals - configuration manual AUDICO AVEC ACCESSORIES ALT 8x8 Transformer unit • Used to convert ADA 8x8’s low impedance • outputs to 50-70-100V lines Supplies also 24VDC priority voltage AAE 800 Paging and control unit Paging • • Programme selection and volume control • Preset activation AAE 804 Fireman’s microphone High priority paging • • Prerecorded evacuation message play buttons Audico Avec configuration software Used to set-up the system • • Runs in a standard Windows PC • Requires USB-port • Requires installation of a USB gadget-driver AUDICO SYSTEMS OY P.O. Box. 39 (Ruunikkokatu 2) 20381 Turku, Finland AAE 806 Paging and control unit • Paging • Programme selection and volume control • Preset activation • 6 buttons to play prerecorded messages AAI 800 Preset buttons and audio input • 3 Preset activation buttons • Audio input with level control ASV 800 Programme and volume control • Up-down buttons to choose channel • Up-down buttons to set volume AEU 100 Line end unit Improves line monitoring performance • • Installed to end of each monitored speakerline Tel. +358- 2- 415 5400 Fax: +358- 2- 415 5450 VAT FI 0982651-1 www.audico.fi audico@audico.fi