0 04.08.09 Issued for Information Rev. Date Description KKH KHJ ADA Made by Checked by Approved by Approved QA Document title: Instrument Datasheet DSP Leak Monitor Document number 62.427.0004.09 Replacement for Revision 0 Replaced by Number of pages 2 DSP Leak Monitor, Ex ia Instrument Datasheet INSTRUMENT DATA GENERAL 1.0 1.1 1.2 Manufacturer Model description Part number CLIENT DATA 2.0 2.1 2.2 2.3 2.4 2.5 2.6 Customer Project title Field / installation P.O. number Part number Tag number Document number / rev. INSTRUMENT LAYOUT NOTE ClampOn AS DSP Leak monitor, Ex ia 930-12xxx-xxx PHYSICAL 3.0 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 Dimensions (ø x h) Material Weight (approximate) Ingress protection Operating temperature Ambient temperature Protective coating Mounting Cable entry Cable gland Cable HARDWARE AND CERTIFICATION 4.0 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 Supply voltage Power consumption Hazardous area Certification code Equipment code Ex certificate number Signal output Protocol Baud rate Microprocessor Diagnostic features 1 80 mm x 144 mm [3.1 in x 5.7 in] AISI 316 Stainless Steel 3 kg [6.6 lb] IP68 -40 C to 150 C [-40 F to 302 F] -40 C to 60 C [-40 F to 140 F] None Clamp on to pipe surface 1 off M20 x 1,5 ISO Metric None* None* 12 VDC to 25 VDC (from I.S PSU) Typical / max: 1,5 W / 2,1 W Zone 0, 1, 2 EEx ia IIB T2-T5 II 1 G DNV-99-ATEX-1004X See note See note See note 66 MIPS Self-testing NOTES 2 1 3, 4 2 3 5 4 6 5 8 3, 8 3, 8 9 9 9 6 7 10 8 OPERATION 5.0 5.1 5.2 5.3 5.4 5.5 Manner of operation Technology Processing Flow conditions Minimum detectable leakage: MTBF Real-time measurement Passive ultrasonic DSP in sensor unit Oil / water / gas / multiphase Liquid: dP >3 bar [44 psi] Gas: dP >1 bar [15 psi] >30 years 9 11 10 11 X notation subject to change according to signal output, cable type/length, and coating. Weight including mounting accessories. ATEX-certified for pipe/valve surface temperature up to 225 °C [437 F].Temperature class depends on pipe/valve surface temperature. See certificate for details. Operating temperature stated for 15 °C [59 °F] ambient temperature. Delivered with mounting skid and clamping bands. Clamping band length 2 m [6.6 ft], covering pipe OD <600 mm DN [24 inch NPS]. Extension clamping band for larger pipe OD, ask supplier for details. For installation of the sensor there must be a minimum of 30 cm [12 in] free space above the pipe. Sensor front must have metal to metal contact with the pipe surface. See installation instructions for further details. Terminals inside sensor enclosure suitable for wire 2 cross section 0,14 to 1,5 mm [AWG 25 to 16]. According to ATEX-certificate the sensor has to be powered from an intrinsically safe power supply. Use only I.S power supply supplied or approved by ClampOn. Additional certification available: CSAc&us Certification code: Class 1 Div 1, Group C & D, T5 Ex certificate no.: 1298002 See certificate for details. Available communication interfaces: RS-485 Proprietary DSP Protocol (9 600 bps or 19 200 bps) Internal self-testing of analogue filters, amplifiers and flash memory. Minimum leakage rate is 0,1 l/min [0.026 gal/min], depending on delta pressure (dP) over the leakage point. *Number of cable entries and size, enclosure material, and cable/cable gland type adaption’s available on request. Ask supplier for details. SYSTEM DESIGN ClampOn DSP Leak Monitor, Ex ia version (also available in Ex de/dem version), is designed to detect leakage or flow-through on pipes and valves. The sensor is non-intrusive and clamped on the pipe surface; hence no parts are in contact with the flow. All ClampOn topside sensors have twoway communication via RS-485, can be upgraded / customized by software download, contain no moving parts and are easy to relocate. A computer running ClampOn software must be used to handle data storage and communication to client control system. ClampOn DSP Leak Monitor, Ex ia Instrument Datasheet 62.427.0004.09