160S.IndustrialBlvd Calhoun,GA30701 Section096519 RESILIENTFLOORING:Trenta™StoneCollection Thisdocumentisintendedasasuggestedguideforeditingyourarchitecturalguidespecification. MohawkGroupwillnotbeheldliablefordamagesarisingoutoftheuseofanyinformationorspecificationsfoundinthisdocument.Makesureyou havethelatestpublicationforthisspecification. Productselectionandaccuracyofallprojectspecificationsarethespecifier’sordesigner’sresponsibility. PART1–GENERALINFORMATION 1.1 SECTIONINCLUDES A. B. Thissectiondealswithresilientflooringfoundinthedrawingsandschedulesofthecontractthatmeetthe requirementsofthissection. RelatedDocuments:Drawingsandgeneralprovisionsofthecontractapplytotheworkofthissection. 1.2RELATEDSECTIONS NotetoSpecifier:Deleteanysectionsbelownotrelevanttothisprojectandaddothersasrequired. A. Division3–Concrete:notcoveredinthissection. B. Division6–Woodandplastic:notcoveredinthissection. C. Division7–Thermalandhumidityprotection:notcoveredinthissection. D. Division9–Othersectionscontaininginformationrelatedtofloorfinishes:notcoveredinthissection. 1.3REFERENCES(INDUSTRYSTANDARDS) A. ASTMF710:PracticeforPreparingConcreteFloorstoReceiveResilientFlooring. B. ASTME648:TestMethodforCriticalRadiantFluxofFloorCoveringSystemsUsingaRadiantHeatEnergy C. ASTME662:TestMethodforSpecificOpticalDensityofSmokeGeneratedbySolidMaterials. D. ASTMF1869:StandardTestMethodforMeasuringMoistureVaporEmissionRateofConcreteSubfloorUsing AnhydrousCalciumChloride. E. ASTMF1700:StandardSpecificationforSolidVinylTile F. ASTM2055:StandardTestMethodforDeterminingSizeandSquarenessofResilientFloorTilebyDialGauge Method G. ASTMF386:StandardTestMethodforThicknessofResilientFlooringMaterialsHavingFlatSurfaces H. ASTM2199:StandardTestMethodforDeterminingDimensionalStabilityofResilientFloorTileafterExposure toHeat I. ASTM970:StandardTestforStaticLoadLimit J. ASTM1914:StandardTestMethodforShort-TermIndentationandResidualIndentationofResilientFloor Covering K. ASTMD2047:StandardTestMethodforStaticCoefficientofFrictionofPolish-CoatedFloorSurfacesas MeasuredbytheJamesMachine Page1of5 6063-M(2016-3-21) L. ASTMF925:StandardTestMethodforResistancetoChemicalsofResilientFlooring M. ASTMF137:StandardTestMethodforFlexibilityofResilientFlooringMaterialswithCylindricalMandrel Apparatus N. ASTMF1515:StandardTestMethodforMeasuringLightStabilityofResilientFlooringbyColorChange O. ASTMF1514:StandardTestMethodforMeasuringHeatStabilityofResilientFlooringbyColorChange 1.4 SUBMITTALS A. Providetheproduct’sTechnicalSpecificationsdatasheetaswellasallInstallationandMaintenance Instructions. B. Whenrequired,supplyfloordrawingsandinstallationplans. C. Supplyasetofsamplesmeasuringatleast3”(7.5cm)by6”(15cm)ofthecompleterangeofcolorsand finisheschosenfortheproject. D. Whenrequired,provideMohawkGroup’sattestation,certifiedbyanindependentlaboratory,confirmingthat theflooringcomplieswiththefirestandardsofthefollowingtests: E. 1.5 2 1. ASTME648;CriticalRadiantFlux:0.45watts/cm ormore 2. ASTME662;SmokeDensity:450orless ProvideMohawkGroup’sWarrantyCertificate. QUALITYASSURANCE A. InstallerQualifications:Installerexperiencedininstallationorapplicationofsystemssimilarincomplexityto thoserequiredforthisproject,includingspecificrequirementsindicated. B. InaccordancewiththetechnicalinstructionsintheInstallationInstructions,usealltheaccessories recommendedbyMohawkGroupwheninstallingitsflooring. NOTETOSPECIFIER:Includeamock-upiftheprojectsizeand/orqualitywarranttakingsuchaprecaution.The followingisoneexampleofhowyoumightspecifyamock-uponalargeproject. 1.6 C. Mock-up:Provideamock-upforevaluationofsurfacepreparationtechnique,applicationworkmanshipand requirementsforexpansioncontrol.Donotproceedwithremainingworkuntilworkmanship,color,sheenand finishedappearanceareapprovedbyarchitect. D. FollowtheinstructionsspecifiedinthemostrecentversionofMohawkGroup’sInstallationInstructions. DELIVERY,HANDLING,STORAGE 1.7 A. DelivertheflooringtotheinstallationsiteinMohawkGroup’soriginalpackaging.Indicatetheprojectname andhandlinginstructionsontheoutsideoftheboxes. B. Advisethecarrierofanydamagedmaterialandindicateitonthepackingslip. C. Storematerialsinaflatinadry,warm,ventilatedandweathertightlocation.Protectflooringproductsfrom damage. D. Installtheflooringafterallotherfinishingwork,includingpainting,havebeencompleted. PROJECTCONDITIONS A. Storetheflooringinside,shelteredfromextremehotorcoldtemperatures.Placethematerialonasmooth levelfloororwherethereisuniformsolidsupportinaclean,drywell-ventilatedarea.Unstackthepallets.The long-termstoragetemperaturemustbemaintainedbetween65°F(18°C)and85°F(29°C).Protectadhesive andflooringmaterialfromfreezing,extremeheatanddirectsunexposure. B. Acclimatizethesubfloor,allflooringmaterialandadhesivefor48hoursbefore,duringandafterthe installationbymaintainingtheroomtemperaturebetween65°F(18°C)and85°F(29°C).Thepalletsshouldbe unstacked24hourspriortouse. Page2of5 6063-M(2016-3-21) C. Afterwards,maintaintheroomtemperaturebetween55°F(13°C)and90°F(32°C).Protectthematerialfrom directsourcesofheatsuchasairventsandothertypesofheaters. D. Donotinstalloncementslabsunlesstheyarethoroughlycleaned,level,structurallysoundandfreefrom paint,varnish,adhesive,oil,grease,solvent,sealerandcuringcompoundsorotherforeignsubstancesthat mayadverselyaffectadhesion. PART2-PRODUCTS 2.1 MANUFACTURER A. COMPANY B. C. MohawkGroup 160SouthIndustrialBlvd. Calhoun,GA30701 Telephone:800-554-6637 Fax:877-244-8054 Website:www.mohawkgroup.com ManufacturermusthaveaheadquartersintheUnitedStatesofAmerica. Alternatesshallbeinthemanufacturer’srunningline.Nospecialruns,customsorspecialconstructionswillbe accepted. 2.2 RESILIENTFLOORINGDESCRIPTION A. Characteristics: 1. LuxuryVinylTile:Trenta™StoneCollection 2. Gauge:3mm(0.12”) 3. ColorsandSizes:11colorsof18”x18” 4. Wearlayer:30mil(0.7mm) 5. ComplieswithASTMF1700,ClassIII,TypeA(Smooth)andTypeB(Embossed) 6. Refertotheproduct’sTechnicalSpecificationsdatasheetfordetailedspecifications. 7. ChoosefromanyoftheMohawkGroup’scompletelineofcolors(indicatetheitemnumber). 8. AllproductsareFloorScore®certified. 9. ThisproductismanufacturedinafactorythathasISO9002andISO14001certifications. 10. Productmustbe100%virginvinylandcontainatleast8%bio-baserenewablematerial. 11. Productmusthaveacommercialgradeurethanewearlayer. 2.3 ADHESIVES A. UseofMohawkGroup’sM700PressureSensitiveorM95.0Acrylicisrequired.M700covers 220-260 sf/gallon andM95.0covers175-225sf/gallonwhenappliedwiththerecommendednotchedtrowel. 2.4 OTHERMATERIAL A. Subfloorrepairs:Useagood-qualityPortland-basedpatchingcompoundmodifiedwithlatexthathasa 2 minimalresistancetocompressionof246kg/cm (3,500lbs/sq.in.)tofill,smoothorlevelsubfloor imperfections. B. Self-levellingunderlayment:UseaPortlandcement-basedself-levellingunderlaymentmodifiedwitha 2 polymerthathasaminimalresistancetocompressionof246kg/cm (3,500lbs/sq.in.). Page3of5 6063-M(2016-3-21) PART3–EXECUTION 3.1 SITEINSPECTION 3.2 A. Examinethesubfloorbeforeinstallationtoensurethatthesurfaceisclean,dry,smooth,structurallysound andfreefromforeignsubstancesthatmayadverselyaffectadhesionorcausediscoloration.Furthermore, ensurethatthesubfloorisfreeofpaint,varnish,adhesive,oil,grease,solventandotherforeignsubstances, includingtreatmentcompounds,sealersandcuringcompoundsthatmayadverselyaffectadhesionoralter theappearanceordurabilityofthevinylflooring. B. Verifythesurfacetoensurethereisnopowder,scalingormold.Ifthereis,removeitwithamechanical sanderandlevelwithagood-qualitycement-basedPortlandprimer. C. Neverremoveresidualorotheradhesivewithchemicaladhesiveremovalproducts;theirusewill automaticallyvoidtheMohawkproductwarranty. D. Reportandrectifyallunsatisfactoryconditions.Donotstartflooringinstallationuntilallrectificationshave beencompleted. SUBFLOORPREPARATION A. Allsubfloorsshouldbesmooth,flatanddustfreewiththetolerancenotexceedingmorethan1/8”ina10’ span.Allsubfloorandunderlaymentpatchingmustbeperformedwithanon-shrinking,water-resistant Portlandcementpatchingcompound. B. Mechanicallyremoveallsurfacecontaminantssuchaspaint,oil,grease,varnish,adhesiveaswellasvarious otherproductssuchastreatmentcompounds. C. MeasurethehumidityandpHlevelsinthecementincompliancewiththefollowingstandardsbefore installation: 1. ASTMF1869,AnhydrousCalciumChloridetestformoisturelevels.Themaximumallowablereadingfor M700adhesiveis5lbs/1,000sq.ft./24hours(2.26kg/92.9sq.m/24hours). 2. ASTMF2170,RelativeHumidity(RH)testusinginsituprobes.Themaximumallowablereadingis: 3. a. 85%RHforM700Adhesive b. 95%RHforM95.0Adhesive ASTMF710,pHlevels(testprocedure5.3.1).Thereadingsshouldbebetween8and9.TheASTMtest frequencyrecommendationis3measuresforthefirst1,000sq.ft.(92.9sq.m)andonemeasureforeach additional1,000sq.ft.(92.9sq.m). D. EnsureMoisture,RelativeHumidityandpHtestshaveallbeenconductedandmeasurementsmeetMohawk Group’srecommendations. E. Incaseofdoubt,testtheadhesiononthecementsubfloororothersurfacethatwillbecoveredbythe flooring.Dothetestusingthespecifiedflooringandrecommendedadhesive. 3.3 RESILIENTFLOORINGINSTALLATION 3.4 A. InstalltheflooringaccordingtothelatestversionofMohawkGroup’sInstallationInstructions.Usethetools, adhesives,troweltypesandproceduresrecommendedintheinstructions. B. Acclimatizethesubfloor,allflooringmaterialandadhesivefor48hoursbeforeandduringtheinstallationby maintainingtheroomtemperaturebetween65°F(18°C)and85°F(29°C).Afterwards,maintainthe temperaturebetween55°F(13°C)and90°F(32°C). CLEANINGANDPROTECTION A. RemoveallexcessadhesiveimmediatelyafterinstallationasrecommendedinMohawkGroup’sInstallation Instructions. B. Beforeallowingtrafficafterinstallation,consultandfollowtherecommendationsinMohawkGroup’s InstallationInstructions. Page4of5 6063-M(2016-3-21) C. Followinginstallationandcleanup,iftheworkofallothertradeshasnotyetbeencompleted,protectthe flooringbylayingsheetsofnon-stainingbrownKraftpaper,andthenalayerofplywoodsheets(rollsofnonstainingheavycardboardmaterialcouldalsobeusedforprotection). D. FollowtheinstructionsinMohawkGroup’sMaintenanceInstructionswhenperforminginitialandregular maintenanceprocedures. ENDOFSECTION096519 Pleasenotethattechnicalwebsitedocumentsprevail. Page5of5 6063-M(2016-3-21)