KUH PDS PF310

advertisement
KUH PDS
KUH
Horizontal
Unit Heater
• 2.6 kW to 45 kW
• 208, 240, 277
480, 600 Volts
• Single or 3-Phase
• 8,900 to 153,600 BTU/Hour
• Wall or Ceiling Mounting
• Meets UL and CSA
Requirements
(600V CSA Certified Only)
Description
Applications
The KUH horizontal unit heater
provides quiet, reliable fan-forced
heating in all types of commercial
and industrial structures. Each
heater houses a bank of Chromalox
patented metal sheath Fintube®
radiating heating elements with
furnace brazed steel fins for long
life and superior heat transfer. KUH
heaters are versatile, flexible, high
performance units that are easily
installed in various mounting
configurations for primary,
supplementary or spot heating
applications. Each unit is selfcontained in a rugged construction
for long life and require little
maintenance. Complementary to
modern structure, these heaters
have a good, clean appearance. For
assured safety, all units meet the
requirements of UL (File No. E7061)
and CSA (File No. LR40859).
The clean design and quality
construction of the KUH heater,
plus meeting UL and CSA requirements, make it a safe, appropriate
heating choice for:
Construction
• Shipping Rooms
• Pump Houses
• Power Generating Stations
• Aircraft Hangers
• Factories
• Warehouses
• Garages
Because it has individually adjustable discharge louvers to direct air
flow, and can be wall or ceiling
(plus swivel) mounted, the KUH
heater may be used in a variety of
heating applications:
• Primary Heating
• Supplementary Heating
• Dual System Heating
• Spot Heating
• Entryway Air Curtain Heating
The cabinet is constructed of heavy
18-gauge steel, phosphate
undercoated for corrosion resistance, and finished in gray powdercoat. Quiet, vibration-free operation
is enabled through the combination
fan guard and motor mount attached to the heating housing with
rubber vibration isolators. Quality
heating element construction
assures years of maintenance-free
operation.
Phone: 1-888-996-9258 • Fax: 615-793-3563
www.chromalox.com
©2005 Chromalox, Inc.
KUH Horizontal Unit Heater
Features
Mount with threaded rods
or optional wall or ceiling
swivel mounting brackets.
Seismic rated.
Totally enclosed fan
motor. Continuous duty
with built-in thermal
cutouts operates on
same voltage as
the heating circuit.
Individually adjustable
louvers to direct air flow
as needed.
Field installed
disconnect switch
(optional)
Field installed summer
fan switch (optional).
Die-formed heavy gauge
steel housing with
attractive gray powder
coat finish.
Field installed thermostat
with adjustment switch
(optional).
Magnetic Contactors
Standard
Electrical & Control Components
The self-contained electrical and
control features of the KUH simplify
installation and ensure safe, long
term operation.
Heavy duty magnetic control
contactors are standard on all models
except single-phase 2.6 thru 5 kW
models, which are standard without
contactors for control by external line
voltage thermostat. Optional contactors
are also available for these models.
• All heaters with a total current
draw of 48 Amps or greater have
electrically balanced, subdivided
circuits with individual fuse
protection. The fuse compartment is conveniently located for
easy access.
• An internal 24 volt control transformer, standard on 480V models, eliminates a need for an
external control source.
2
Horizontal type heaters mount on
wall or ceiling. Recessed welded
fasteners on top of housing are
internally threaded for suspension of
unit with threaded rods. Also there
are optional ceiling and wall swivel
mounting brackets. The ceiling
bracket lets you mount the Horizontal Unit Heater direct to the ceiling
or overhead member, simply and
easily. The wall swivel mounting
bracket makes for easy wall mounting. Swivel type mounting lets you
readily adjust direction of warm air
flow for optimum comfort, 180
degrees if need be.
• The Electric Heat Bank —
Chromalox patented metal sheath
Fintube® heating elements. Heat
radiating fins are steel, furnace
brazed to the tubular heating
elements for good heat transfer.
They don’t come loose! Wide
spacing minimizes clogging.
• Thermal overload cutouts open
the control circuit and disconnect
power to the heating elements if
overheating occurs. Automatic
reset allows the control circuit to
reclose and restore power when
the temperature falls to normal
levels.
• Dynamically balanced fan for
smooth, quiet running. Blade
pitch is carefully selected so that
the volume of air moved results in
the optimum discharge air
temperature.
• 103 Gamma Drive Ext. • Pittsburgh, PA 15238 • PH: 1-800-443-2640 • www.chromalox.com
KUH Horizontal Unit Heater
Specifications And Ordering Information
To order please specify kW, volts, phase, catalog number, PCN and quantity. See back page for control, thermostat and fan options.
Electrical Data (60 Hz)
Fan Motor
Mounting Data
Phase
Amps
BTU/H
Volts
Phase
RPM
HP
Air
Fan
Dia.
2,667
2,000/2,667
2,667
1
1
1
12.8
11.1***
9.6
8,850
8,850
8,850
208
240
277
1
1
1
1650
1650
1550
1/40
1/40
1/30
9”
9”
9”
410
410
360
21°
21°
24°
8’
8’
8’
12’
12’
12’
KUH-02-81-00
KUH-02-21-00
KUH-02-71-00
S
S
S
304004
304012
304020
35
208
208
208/240
208/240
277
480
4,000
4,000
3,000/4,000
3,000/4,000
4,000
4,000
1
3
1
3
1
3
19.2
11.2
16.7***
9.6***
14.5
4.8
13,661
13,661
13,661
13,661
13,661
13,661
208
208
240
240
277
480
1
1
1
1
1
1
1650
1650
1650
1650
1550
1550
1/40
1/40
1/40
1/40
1/30
1/35
9”
9”
9”
9”
9”
9”
410
410
410
410
360
380
31°
31°
31°
31°
35°
33°
8’
8’
8’
8’
8’
8’
12’
12’
12’
12’
12’
12’
KUH-04-81-00
KUH-04-83-34
KUH-04-21-00
KUH-04-23-34
KUH-04-71-00
KUH-04-43-30
S
S
S
S
S
S
304039
304047
304055
304063
304071
304080
35
5
5
3.75/5
3.75/5
5
5
208
208
208/240
208/240
277
480
5,000
5,000
3,750/5,000
3,750/5,000
5,000
5,000
1
3
1
3
1
3
24.0
13.8
20.8***
12.1***
18.2
6.0
17,076
17,076
17,076
17,076
17,076
17,076
208
208
240
240
277
480
1
1
1
1
1
1
1650
1650
1650
1650
1550
1550
1/40
1/40
1/40
1/40
1/30
1/35
9”
9”
9”
9”
9”
9”
410
410
410
410
360
380
39°
39°
39°
39°
44°
42°
8’
8’
8’
8’
8’
8’
12’
12
12
12
12
12
KUH-05-81-00
KUH-05-83-34
KUH-05-21-00
KUH-05-23-34
KUH-05-71-00
KUH-05-43-30
S
S
S
S
S
S
304098
304100
304119
304127
304135
304143
35
7.5
7.5
5.6/7.5
5.6/7.5
7.5
7.5
7.5
208
208
208/240
208/240
277
480
600
7,500
7,500
5,625/7,500
5,625/7,500
7,500
7,500
7,500
1
3
1
3
1
3
3
36.1
20.9
31.1***
18.1***
27.2
9.0
7.0
25,598
25,598
25,598
25,598
25,598
25,598
25,598
208
208
240
240
277
480
575
1
1
1
1
1
3
3
1725
1725
1725
1725
1550
1725
1725
1/15
1/15
1/15
1/15
1/15
1/15
1/3
12”
12”
12”
12”
12”
12”
12”
850
850
850
850
750
850
850
28°
28°
28°
28°
32°
28°
28°
8’
8’
8’
8’
8’
8’
8’
27’
27’
27’
27’
27’
27’
27’
KUH-07-81-34
KUH-07-83-34
KUH-07-21-34
KUH-07-23-34
KUH-07-71-30
KUH-07-43-30
KUH-07-63-32
S
S
S
S
S
S
NS
304151
304160
304178
304186
304194
304207
000000
55
9.7
9.7
7.5/10
7.5/10
10
10
208
208
208/240
208/240
480
600
10,000
10,000
7,500/10,000
7,500/10,000
10,000
10,000
1
3
1
3
3
3
48.0
27.8
41.7***
24.0***
12.0
10.0
34,130
34,130
34,130
34,130
34,130
34,130
208
208
240
240
480
575
1
1
1
1
3
3
1725
1725
1725
1725
1725
1725
1/15
1/15
1/15
1/15
1/15
1/3
12”
12”
12”
12”
12”
12”
850
850
850
850
850
850
37°
37°
37°
37°
37°
37°
9’
9’
9’
9’
9’
9’
27’
27’
27’
27’
27’
27’
KUH-10-81-34
KUH-10-83-34
KUH-10-21-34
KUH-10-23-34
KUH-10-43-30
KUH-10-63-32
S
S
S
S
S
NS
304215
304223
304231
304240
304258
000000
55
12.5
9.3/12.5
12.5
12.5
208
208/240
480
600
12,500
9,375/12,500
12,500
12,500
3
3
3
3
34.8
30.1***
15.1
12.0
42,663
42,663
42,663
42,663
208
240
480
575
1
1
3
3
1725
1725
1725
1725
1/15
1/15
1/15
1/3
12”
12”
12”
12”
850
850
850
850
47°
47°
47°
47°
9’
9’
9’
9’
27’
27’
27’
27’
KUH-12-83-34
KUH-12-23-34
KUH-12-43-30
KUH-12-63-32
S
S
S
NS
394266
304274
304282
000000
55
15
11.25/15
15
15
208
15,000
208/240 11,250/15,000
480
15,000
600
15,000
3
3
3
3
41.8
36.2***
18.1
15.0
51,195
51,195
51,195
51,195
208
240
480
575
1
1
3
3
1725
1725
1725
1725
1/15
1/15
1/15
1/3
12”
12”
12”
12”
850
850
850
850
56°
56°
56°
56°
10’
10’
10’
10’
27’
27’
27’
27’
KUH-15-83-34
KUH-15-23-34
KUH-15-43-30
KUH-15-63-32
S
S
S
NS
304290
304303
304311
000000
55
20
20
20
208/240 15,000/20,000
480
20,000
600
20,000
3
3
3
48.0***
24.0
19.0
68,460
68,460
68,460
240
480
**
3
3
3
1725
1725
1725
1/3
1/3
1/3
14”
14”
14”
1240
1240
1240
53°
53°
53°
11’
11’
11’
31’
31’
31’
KUH-20-23-34
KUH-20-43-30
KUH-20-63-32
S
S
NS
304320
304338
000000
75
3
3
30.0
24.0
85,525
85,525
480
**
3
3
1725
1725
1/3
1/3
14”
14”
1350
1350
60°
60°
12’
12’
31’
31’
KUH-25-43-30
KUH-25-63-32
S
NS
304346
000000
75
kW
Volts
Watts
2.6
2.0/2.6
2.6
208
208/240
277
4
4
3/4
3/4
4
4
25
25
480
600
25,000
25,000
Temp.
Velo. Rise
CFM
°F
Max.
Ht.
Hor.
Catalog
Throw No.
Status* PCN
Wt.
lbs.
30
30
30
30
208
30,000
208/240 22,500/30,000
480
30,000
600
30,000
3
3
3
3
83.4
72.2***
36.1
29.0
102,390
102,390
102,390
102,390
240
240
480
**
3
3
3
3
1725
1725
1725
1725
1/3
1/3
1/3
1/3
14”
14”
14”
14”
1555
1555
1555
1555
64°
64°
64°
64°
13’
13’
13’
13’
46’
46’
46’
46’
KUH-30-83-34
KUH-30-23-34
KUH-30-43-30
KUH-30-63-32
S
S
S
NS
304354 110
304362
304370
000000
35
35
35
208/240 26,250/35,000
480
35,000
600
35,000
3
3
3
84.3***
42.1
34.0
119,455
119,455
119,455
240
480
**
3
3
3
1725
1725
1725
1/3
1/3
1/3
14”
14”
14”
1555
1555
1555
71°
71°
71°
14’
14’
14’
45’
45’
45’
KUH-35-23-34
KUH-35-43-30
KUH-35-63-32
S
S
NS
304389 110
304397
000000
40
40
40
208/240 30,000/40,000
480
40,000
600
40,000
3
3
3
96.0***
48.0
39.0
136,520
136,520
136,520
240
480
**
3
3
3
1725
1725
1725
1/3
1/3
1/3
14”
14”
14”
1555
1555
1555
84°
84°
84°
15’
15’
15’
44’
44’
44’
KUH-40-23-34
KUH-40-43-30
KUH-40-63-32
S
S
NS
304400 110
304418
000000
3
3
54.1
43.0
153,585
153,585
480
**
3
3
1725
1725
1/3
1/3
14”
14”
1555
1555
94°
94°
17’
17’
42’
42’
KUH-45-43-30
KUH-45-63-32
S
NS
304426 110
000000
45
45
480
600
45,000
45,000
* S = Stock; NS = Non-Stock
** Check factory for motor data
*** 208V amperage is 86% of 240V value
Notes:
1.All heaters have built-in contactors except 2.6 thru 5 kW Single Phase Models, and stock 480 volt models have built-in control transformers and
contactor with 24 volt holding coils. All stock 208 and 240 volt models have 208/240 volt holding coils. All stock 277 volt models have 277 volt holding
coils.
2.Optional contactors are available with 24 volt holding coils on made to order models.
When total heater capacity exceeds 48 amps, built-in fusing is provided behind a hinged and latched door in the side which allows easy
access.
• 103 Gamma Drive Ext. • Pittsburgh, PA 15238 • PH: 1-800-443-2640 • www.chromalox.com
3
KUH Horizontal Unit Heater
Application Tips
Small rooms can be heated by a
one (1) unit heater. Where two (2)
walls are exposed, heater should be
mounted as shown.
Large rooms require multi-unit
installations. Number and capacity
of units will be determined by
volume of building and square feet
of floor area to be heated. Arrange
units to provide perimeter air
circulation.
To prevent air stratification, total
CFM capacity of all units should
circulate the room air volume at
least 3 times per hour. Units should
be located so their air streams wipe
exposed walls without blowing
directly at them.
In multiple unit heater installations, locate units so each unit
supports the air stream from
another, thus setting up circulatory
air movement.
In warehouse type applications,
for maintaining minimum temperature, one or more large heaters can
be used to reduce initial installation
expense.
For individual spaces total heating
capacity is calculated in the conventional way, using formulas in the
ASHRAE “Guide” or those found in
the NEMA handbook.
For pedestrian entryways when
heating capacity is not known, a
“rule of thumb” is 3000-5000 watts
per door. Use 3000 watts per door
for a low traffic single-door entry.
For a large multiple-door entry, or a
high traffic single-door entry, use
5000 watts per door.
Loading Docks. Unit heaters are
used to combat cold air inrush
when loading dock doors are
opened. For such applications, one
or more units should be arranged to
blow warm air across the opening,
not toward it.
Mounting Recommendations
Hazardous Atmosphere - KUH
Horizontal Unit heaters should not
be used in potentially explosive
atmospheres.
Corrosive Atmosphere - The finish
is not intended for direct salt spray
exposure in marine applications or
the highly corrosive atmosphere of
greenhouses, swimming pools,
chemical storage bins, etc.
Mounting Height - Do not install
heaters above recommended
maximum mounting height.
Obstructions - Must not block
heater air inlet or discharge.
Warning - This heater is not intended for use in hazardous atmospheres where flammable vapors,
gases, liquids or other combustible
atmospheres are present as defined
in the National Electric Code. Failure
to comply can result in explosion or
fire.
Suggested Engineering Specifications
Furnish and install Chromalox type
KUH Horizontal Unit Heaters with
heating and air delivery capacities as
shown on the heating schedule.
Mounting brackets designed for
either ceiling or wall swivel mounting
shall be furnished as shown on the
heating schedule. The cabinet shall
be of 18 gauge die formed furniture
grade steel. Individual adjustable
louvers shall be furnished to provide
desired control of discharge air. All
metal surfaces of the casing shall be
phosphate coated to resist corrosion,
and finished in gray powder coated
paint.
The electric heating bank shall
consist of our metal sheath Fintube®
heating elements. Automatic reset
4
thermal overheat protection shall be
wired for instantaneous pilot operation of built-in control contactor
holding coil. Single phase units 2.6
thru 5kW shall have cutout wired in
series with the motor and element.
All heaters drawing more than 48
amperes shall have built-in branch
circuit fusing for protection.
Motors shall be of the totally
enclosed continuous fan-duty sleeve
bearing type equipped with built-in
thermal overload protection. Each
unit shall be equipped with a combination fan guard/motor support
resiliently mounted at four points to
absorb any motor vibration. Fans
shall be aluminum, directly connected to fan motor, dynamically
balanced and designed specifically
for unit heater application.
Optional control transformers shall
be available to internally develop
safer low voltage for pilot-duty
control circuits. Fan switching
devices shall be available to independently operate the fan motor for
summer circulation and winter heat
recovery.
Individual optional built-in comfort
control thermostat is integral or
remote fan only switch and disconnect switch shall be available, for all
models. All heaters should be UL
Listed and CSA Certified and meet
the requirements of the National
Electrical Code.
• 103 Gamma Drive Ext. • Pittsburgh, PA 15238 • PH: 1-800-443-2640 • www.chromalox.com
KUH Horizontal Unit Heater
Dimensions
Welded fasteners (4)
for threaded rod**
Mounting to
overhead steel.
Note: Heater must be mounted at least 7’ above floor.
Minimum
distance
to wall
* Fasteners for mounting bracket to ceiling
or wall not supplied.
** Threaded rod not supplied.
Wall
line
Minimum distance
to wall with ceiling mount.
Dimensions — Inches
Catalog Number
A
B
C
D
Welded Fasteners
E
F
G
H
I
J
K
KUH-02 thru -05
16
131/8
87/8
111/16
5
101/4
93/4
51/2
41/16
41/2
41/2
65/8
3
/8-16
13 /8
13
1
8 /4
1
4 /2
1
6 /4
1
6 /4
85/8
3
/8-16
161/4
16
81/4
6
81/4
61/4
10
16
1
6
3
3
10
1
1
1
KUH-07, 10, 12, 15
20 /2
17 /4
11 /2
15
KUH-20, 25
24
201/8
111/2
173/4
KUH-30, 35, 40, 45
1
20 /8
24
17
7
23 /8
W
N
V
M
Wall
One /16”
mounting
hole for swivel
mounting to
ceiling.
U
7
1
/8-16
16 /4
8 /4
11 /4
11 /4
Wall Mounted
Universal Bracket
Ceiling Mounted
11
3
/16-18
413/32” diameter mounting
holes for fastening to wall.*
Stop for limiting rotation.
Swivel bolt permits heater to be
rotated to face desired direction.
Four bolts are provided for field
attachment of swivel bracket to
welded fasteners on top of unit.
A
Mounting Limitations
Swivel Mounting
Bracket*
Finished ceiling
Four bolts are
provided for field
attachment of
swivel bracket to
welded fasteners
on top of unit.
Ceiling must
be smooth wood,
plaster or metal
surface with
adequate strength
to support heater.
Not adaptable to
acoustic tile or
suspended
ceilings.
Hazardous Atmosphere — Unit heaters should
not be used in potentially explosive atmospheres. Corrosive Atmosphere — The finish is
not intended for direct salt spray exposure in
marine applications or the highly corrosive
atmospheres of greenhouses, swimming pools,
chemical storage bins, etc. Mounting Height — Do
not install Unit Heaters above recommended
maximum mounting height. Obstructions must
not blockunit heater air inlet or discharge.
Clearance Requirements
Mounting Limitations
Side To Wall
6 inches
Back To Wall
6 inches
Ceiling Mounted Heaters
Wall Mounted Heaters
Dimensions — Inches
Heater Model
#
A
KUH-02 thru -05
16
KUH-07, 10, 12, 15
KUH-20, 25
M
6
201/2 8
24
8
N
47/16
43/4
61/4
U
4
6
6
V
43/4
71/4
71/4
Dimensions — Inches
W
101/2
16
171/2
Ceiling Bracket Cat.
Heater Model
P
Q
R
S
T
KUH-02 thru -05
11/2
211/2
63/4
55/8
141/2
24
133/4 95/16 6
71/4
21
Wall Bracket Cat. #
1
3
BUH-01A
BUH-04A
KUH-07, 10, 12, 15
3
19
5
2 /32
28 /32 9 /2
8 /8
19 /8
BUH-02A
KUH-20, 25
23/32
2819/32 91/2
83/8
195/8
BUH-02A
BUH-05A
BUH-05A
KUH-30, 35, 40, 45
KUH-30, 35, 40, 45
Top To Wall
6 inches
1
5 /2
3
30 /4
5
1
3 /2
9
32 /16
BUH-03A
BUH-06A
• 103 Gamma Drive Ext. • Pittsburgh, PA 15238 • PH: 1-800-443-2640 • www.chromalox.com
5
KUH Horizontal Unit Heater
Optional Control Accessories and Remote Thermostats
Fan Only Operation Kits
Thermostat Kits
Catalog Number
KUH-TK3 (SPST)
KUH-TK4 (DPST)
PCN
302519
302527
Summer Fan
Switch
Power Disconnect Kits
Thermostat Kit
A fan only operation (optional) is available by means of a built-in
switch or by external control.
(2-15 kW)
(20-45 kW)
Catalog Number
3 Pole, 600V Rating
Catalog Number
KDS-1
KDS-2
KDS-3
6
Rating
40 Amp
80 Amp
100 Amp
PCN
304434
304442
304450
Description
ISFS-02 Internal Summer Fan Switch
208 through 277Volts
ESFS-40 External* Summer Fan Switch
With Relay (24 Volt control)
ESFS-42 External* Summer Fan Switch
With Relay (240 Volt control)
ESFS-47 External* Summer Fan Switch
With Relay (277 Volt control)
PCN
PCN
305007
ISFS-02
305007
305015
ESFS-40A
305058
305031
ESFS-42A
305074
305040
—
—
*Kit includes wall plate (discard plate if switch is to be installed on the heater.)
• 103 Gamma Drive Ext. • Pittsburgh, PA 15238 • PH: 1-800-443-2640 • www.chromalox.com
KUH Horizontal Unit Heater
Recommended Remote Wall Thermostats
Industrial Rated
NOT A FAIL-SAFE DEVICE
Maximum Rating (Amps/Watts) AC
120V
240V
277V
480V
DC†
115V
25/3000
25/3000
22/5280
22/5280
18/5000
18/5000
125VA*
125VA*
125VA**
125VA**
DC† Catalog Sta230V Number tus
125VA**
125VA**
WR-80
WR-90
S
S
PCN
263177
263185
WR-80
SPST
40°F - 80°F
UL Listed
WR-90
SPST
20°F - 90°F
UL Listed
*Pilot Duty (Use With AC Contactor)
**Pilot Duty (Use With DC Contactor)
†DC Ratings Not UL Listed
Light Duty
NOT A FAIL-SAFE DEVICE
Maximum Rating (Amps/Watts) AC
Pilot duty Catalog Sta(VA)
Number tus
120V
208V
240V
277V
22/2640
22/2640
22/4575
22/4575
22/5280
22/5280
18/5000
18/5000
125
125
WT-121
WT-122
S
S
Line Voltage
PCN
309999
310009
WT-122
WT-121
DPST
SPST
45°F - 75°F 45°F - 75°F
Low Voltage
WTL-121
SPST
40°F - 80°F
30 VAC
1 Amp
Thermostat and Fan Switch
NOT A FAIL-SAFE DEVICE
Catalog
Number
Status
PCN
RTC-90
Surface Mounting Box
S
S
227360
227379
Electrical Rating
VAC
FLA
Inductive
LRA
125
250
277
5.8
2.9
2.4
34.8
17.4
14.4
Pilot Duty
(VA)
Resistive
(Amps)
125
125
125
10
5.0
4.2
RTC-90
50°F - 90°F
UL Listed
• 103 Gamma Drive Ext. • Pittsburgh, PA 15238 • PH: 1-800-443-2640 • www.chromalox.com
7
KUH Horizontal Unit Heater
Model Numbers
When ordering KUH heaters, specify the model number and corresponding PCN (Product Code Number). If controls or
thermostat/fan options are required, designate these options in the model number when ordering, as shown below. Always
specify voltage, phase and kW by listing them on the purchase order product specifications.
KUH
05
21
34
41
1
Disconnect Switch
1 40 Amp
2 80 Amp
3 100 Amp
Control
0
4
4
4
4
4
4
0
0
1
2
3
4
5
No Thermostat, No Summer Fan Switch
Internal Thermostat Only
Internal Therm. and Internal Sum. Fan Sw.
External Sum. Fan Sw. Only (Not 480V)
External Sum. Fan Sw. and Fan Relay (All Volts)
Rem. Fan Sw. and Internal Therm. (Not 480V)
Rem. Fan Sw., Fan Relay and Int. Therm. (All Volts)
Control
0
3
3
3
3
0
0
1
4
5
No Contactor(s)
24V Control Internal Transformer
24V Control Externally Supplied
208/240V Control Internally Supplied, No Transformer
277V Control Internally Supplied
Heater Voltage and Phase
81 = 208V, 1 Phase
83 = 208V, 3 Phase
21 = 240V, 1 Phase
23 = 240V, 3 Phase
71 = 277V, 1 Phase
43 = 480V, 3 Phase
63 = 600V, 3 Phase
Heating Elements
02 = 2.6 kW
04 = 4.0 kW
05 = 5.0 kW
07 = 7.5 kW
10 = 10.0 kW
12 = 12.5 kW
15 = 15.0 kW
20 = 20.0 kW
25 = 25.0 kW
30 = 30.0 kW
35 = 35.0 kW
40 = 40.0 kW
45 = 45.0 kW
Chromalox Horizontal Unit Heater
PF310-2
PDS KUH
FEB05
8
• 103 Gamma Drive Ext. • Pittsburgh, PA 15238 • PH: 1-800-443-2640 • www.chromalox.com
Download